}

Tender For Running Works Contract For Repairing & Reconditioning Of Sick Distribution Transformersat Special Maintenancerepair Bay Thimmavaram Inchengalpattu Circle., tangedco-Tamil Nadu

Tamil Nadu Generation And Distribution Corporation Limited has published Tender For Running Works Contract For Repairing & Reconditioning Of Sick Distribution Transformersat Special Maintenancerepair Bay Thimmavaram Inchengalpattu Circle.. Submission Date for this Tender is 27-12-2022. Coats and Jackets Tenders in tangedco Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

35290623
Tender For Running Works Contract For Repairing & Reconditioning Of Sick Distribution Transformersat Special Maintenancerepair Bay Thimmavaram Inchengalpattu Circle.
Open Tender
Indian
Tamil Nadu
Tangedco
27-12-2022

Tender Details

Running Works Contract For Repairing & Reconditioning Of Sick Distribution Transformersat Special Maintenancerepair Bay Thimmavaram Inchengalpattu Circle - Coils : 3 ( I ) H.V. Coils : 4 ( I ) D.P.C. Copper / Kg : 5 ( A ) 16 / 25 / 40 Kva : 11Kv 6 ( B ) 63 / 100 Kva : 11Kv 7 ( C ) 150 / 200 / 250 Kva : 11 Kv 8 ( D ) 500 Kva : 11Kv 9 ( Ii ) S.E.C. / Kg ( Copper ) : 10 ( A ) 16 / 25 / 40 Kva : 11 Kv 11 ( B ) 63 / 100 Kva : 11 Kv 12 ( C ) 150 / 200 / 250 Kva : 11 Kv 13 ( D ) 500 Kva : 11Kv 14 ( Iii ) D.P.C. Aluminium / Kg : 15 ( A ) 16 / 25 / 40 Kva : 11Kv 16 ( B ) 63 / 100 Kva : 11 Kv 17 ( C ) 150 / 200 / 250 Kva : 11Kv 18 ( D ) 500 Kva : 11Kv 19 ( Iv ) S.E.A. Aluminium / Kg : 20 ( A ) 16 / 25 / 40 Kva : 11 Kv 21 ( B ) 63 / 100 Kva : 11Kv 22 ( C ) 150 / 200 / 250 Kva : 11Kv 23 ( D ) 500 Kva : 11Kv 24 ( Ii ) L.V.Coils : 25 ( I ) D.P.C. Copper / Kg.: 26 ( A ) 16 / 25 / 40 Kva : 11Kv 27 ( B ) 63 / 100 Kva : 11Kv 28 ( C ) 150 / 200 / 250 Kva : 11Kv 29 ( D ) 500 Kva : 11Kv 30 ( Ii ) T.P.C. Copper / Kg.: 31 ( A ) 16 / 25 / 40 Kva : 11 Kv 32 ( B ) 63 / 100 Kva : 11Kv 33 ( C ) 150 / 200 / 250 Kva : 11Kv 34 ( D ) 500 Kva : 11Kv 35 ( Iii ) S.E.C. / Kg ( Copper ) : 36 ( A ) 16 / 25 / 40 Kva : 11 Kv 37 ( B ) 63 / 100 Kva : 11Kv 38 ( C ) 150 / 200 / 250 Kva : 11 Kv 39 ( D ) 500 Kva : 11Kv 40 ( Iv ) D.P.C. Aluminium / Kg : 41 ( A ) 16 / 25 / 40 Kva : 11 Kv 42 ( B ) 63 / 100 Kva : 11Kv 43 ( C ) 150 / 200 / 250 Kva : 11Kv 44 ( D ) 500 Kva : 11Kv 45 ( V ) S.E.A. Aluminium / Kg: 46 ( A ) 16 / 25 / 40 Kva : 11 Kv 47 ( B ) 63 / 100 Kva : 11Kv 48 ( C ) 150 / 200 / 250 Kva : 11 Kv 49 ( D ) 500 Kva : 11Kv 50 H.T.Bushing - Is 3347 / Each Of All Capacities 51 ( A ) 11Kv 52 ( A ) 11Kv 53 L.T. Bushing - Is 3347 / Each 54 ( A ) 16 / 25 / 40 Kva : 11Kv 55 ( B ) 63 / 100 Kva : 11Kv 56 ( C ) 150 / 200 / 250 Kva : 11 Kv 57 ( D ) 500 Kva : 11Kv 58 H.T. Rods ( Brass ) Per / Each : Is 3347 Of All Capacities 59 ( A ) 11Kv 60 11Kv 61 L.T. Rods ( Copper ) Per / Each : Is 3347 62 ( A ) 16 / 25 / 40 Kva : 11Kv 63 ( B ) 63 / 100 Kva : 11Kv 64 ( C ) 150 / 200 / 250 Kva : 11Kv 65 ( D ) 500 Kva : 11Kv 66 Breather With Silica Gel 67 ( A ) 250 Gm 68 ( B ) 500 Gm 69 ( C ) 1000 Gm 70 Tap Switch Per Each : 71 ( A ) 63 / 100 Kva : 11 Kv 72 ( B ) 63 / 100 Kva : 11 Kv 73 ( C ) 150 / 200 / 250 Kva : 11 Kv 74 ( D ) 150 / 200 / 250 Kva : 11 Kv 75 ( E ) 500 Kva : 11 Kv 76 ( F ) 500 Kva : 11 Kv 77 H.T. Bushing Nut ( Brass ) Of All Capacities And Ratings 78 L.T. Bushing Nut ( Copper ) Per Each 79 ( A ) 16 / 25 / 40 Kva : 11Kv 80 ( B ) 63 / 100 Kva : 11Kv 81 ( C ) 150 / 200 / 250 Kva : 11Kv 82 ( D ) 500 Kva : 11Kv 83 Silicagel Per Kg 84 Wheel Valve Of Size Per Each Superior Quality 85 3 / 4 86 1 87 1.25 88 1.5 89 New Transformer Oil Per Litre: 90 Crgo Lamination Per Kg.For All Capacities And Ratings : 91 Superior Than Crgo Lamination Per Kg.For All Capacities And Ratings 92 Supply Of Guage Glass For All Capacities And Ratings : 93 Supply Of Diaphram For All Capacities And Ratings : 94 Supply Of Radiator Tubes, Fins Per Each : 95 Fins 96 ( A ) 16 / 25 / 40 Kva : 11Kv 97 ( B ) 63 / 100 Kva : 11Kv 98 ( C ) 150 / 200 / 250 Kva : 11 Kv 99 ( D ) 500 Kva : 11 Kv 100 Tubes 101 ( A ) 16 / 25 / 40 Kva : 11 Kv 102 ( B ) 63 / 100 Kva : 11 Kv 103 ( C ) 150 / 200 / 250 Kva : 11 Kv 104 ( D ) 500 Kva : 11Kv 105 Supply Of Inter Coil Insulation Per Limb For All Capacities And Ratings 106 Supply Of Washers Per Each : 107 ( A ) 16 / 25 / 40 Kva : 11 Kv 108 ( B ) 63 / 100 Kva : 11Kv 109 ( C ) 150 / 200 / 250 Kva : 11Kv 110 ( D ) 500 Kva : 11 Kv 111 ( I ) Aluminium Paint Or Grey Paint Per Transformer: 112 ( A ) 16 / 25 / 40 Kva : 11Kv 113 ( B ) 63 / 100 Kva : 11Kv 114 ( C ) 150 / 200 / 250 Kva : 11Kv 115 ( D ) 500 Kva : 11Kv 116 ( Ii ) Oil Resistance Paint Per Transformer 117 ( A ) 16 / 25 / 40 Kva : 11Kv 118 ( B ) 63 / 100 Kva : 11 Kv 119 ( C ) 150 / 200 / 250 Kva : 11 Kv 120 ( D ) 500 Kva : 11Kv 121 Reinsulation Of L.V. Coils Per / Kg For All Capacities And Ratings ( Dpc ) 122 Reinsulation Of L.V. Coils Per / Kg For All Capacities And Ratings ( Tpc ) 123 Supply Of Core Clamp For All Capacities And Ratings 124 Supply Of Gasket For Tank Cover / Transformer: 125 ( A ) 16 / 25 / 40 Kva : 11Kv 126 ( B ) 63 / 100 Kva : 11Kv 127 ( C ) 150 / 200 / 250 Kva : 11Kv 128 ( D ) 500 Kva : 11Kv 129 Labour 130 Opening, Lifting The Core And Re-Examination: 131 ( A ) 16 / 25 / 40 Kva : 11Kv 132 ( B ) 63 / 100 Kva : 11Kv 133 ( C ) 150 / 200 / 250 Kva : 11Kv 134 ( D ) 500 Kva : 11Kv 135 ( I ) Positioning The Core Back After Repairs And Complete Electrical Connection And Boxing Up With Top Cover For Repairable Transformer: 136 ( A ) 16 / 25 / 40 Kva : 11Kv 137 ( B ) 63 / 100 Kva : 11Kv 138 ( C ) 150 / 200 / 250 Kva : 11Kv 139 ( D ) 500 Kva : 11 Kv 140 ( Ii ) Positioning The Core Back After Repairs And Complete Electrical Connection And Boxing Up With Top Cover For Irreparable Transformer: 141 ( A ) 16 / 25 / 40 Kva : 11Kv 142 ( B ) 63 / 100 Kva : 11Kv 143 ( C ) 150 / 200 / 250 Kva : 11 Kv 144 ( D ) 500 Kva : 11Kv 145 ( Iii ) Electrical Connection : 146 ( I ) For Star Connection: 147 ( A ) 16 / 25 / 40 Kva : 11Kv 148 ( B ) 63 / 100 Kva : 11Kv 149 ( C ) 150 / 200 / 250 Kva : 11Kv 150 ( D ) 500 Kva : 11Kv 151 ( Ii ) For Delta Connection: 152 ( A ) 16 / 25 / 40 Kva : 11Kv 153 ( B ) 63 / 100 Kva : 11Kv 154 ( C ) 150 / 200 / 250 Kva : 11Kv 155 ( D ) 500 Kva : 11Kv 156 Replacement Of Each Defective H.T. Bushing With Its Attendant Works For All Capacities And Ratings: 157 Replacement Of Each Defective Lt. Bushing With Its Attendant Works For All Capacities And Ratings: 158 Replacement Of Each Defective H.T. Bushing Rods With Its Attendant Works For All Capacities And Ratings: 159 Replacement Of Each Defective L.T. Bushing Rods With Its Attendant Works For All Capacities And Rating 160 ( A ) 16 / 25 / 40 Kva : 11Kv 161 ( B ) 63 / 100 Kva : 11Kv 162 ( C ) 150 / 200 / 250 Kva : 11Kv 163 ( D ) 500 Kva : 11Kv 164 Cleaning Of Internal Surfaces Of Tank Tubes, Conservator Tank Etc, And Painting And Make Them Fit For Use ( Excluding Cost Of Paints ) Per Transformer: 165 ( A ) 16 / 25 / 40 Kva : 11 Kv 166 ( B ) 63 / 100 Kva : 11Kv 167 ( C ) 150 / 200 / 250 Kva : 11Kv 168 ( D ) 500 Kva : 11 Kv 169 Cleaning, Scratching The External Surfaces Of Transformer And Painting With Good Aluminium Paint Two Coats ( Excluding Cost Of Paints ) Per Transformer: 170 ( A ) 16 / 25 / 40 Kva : 11Kv 171 ( B ) 63 / 100 Kva : 11Kv 172 ( C ) 150 / 200 / 250 Kva : 11 Kv 173 ( D ) 500 Kva : 11Kv 174 Charges For Hot Oil Circulation After Filling ( Per Litre ) For All Capacities And Ratings 175 Drying Out Of The Repaired Core After Assembly Of The Coils 176 ( A ) 16 / 25 / 40 Kva : 11Kv 177 ( B ) 63 / 100 Kva : 11Kv 178 ( C ) 150 / 200 / 250 Kva : 11Kv 179 ( D ) 500 Kva : 11Kv 180 Conducting Of Routine Test In The Repair Units Per Transformer 181 ( A ) 16 / 25 / 40 Kva : 11 Kv 182 ( B ) 63 / 100 Kva : 11Kv 183 ( C ) 150 / 200 / 250 Kva : 11Kv 184 ( D ) 500 Kva : 11Kv 185 Replacement Of Coils : 186 ( I ) Removal Of Failed H.T.Coil ( Per / Coil ) 187 ( A ) 16 / 25 / 40 Kva : 11 Kv 188 ( B ) 63 / 100 Kva : 11 Kv 189 ( C ) 150 / 200 / 250 Kva : 11Kv 190 ( D ) 500 Kva : 11Kv 191 ( Ii ) Removal Of Failed L.T.Coilper / Coil 192 ( A ) 16 / 25 / 40 Kva : 11 Kv 193 ( B ) 63 / 100 Kva : 11Kv 194 ( C ) 150 / 200 / 250 Kva : 11Kv 195 ( D ) 500 Kva : 11Kv 196 Welding Per / Cm : 197 ( A ) 16 / 25 / 40 Kva : 11Kv 198 ( B ) 63 / 100 Kva : 11Kv 199 ( C ) 150 / 200 / 250 Kva : 11Kv 200 ( D ) 500 Kva : 11Kv 201 Breather Fixing Each For All Capacities And Ratings 202 Removal And Repairing And Refixing The Tap Switch With All Alliedworks : 203 ( A ) 63 / 100 Kva : 11 Kv 204 ( B ) 150 / 200 / 250 Kva : 11Kv 205 ( C ) 500 Kva : 11Kv 206 Replacement Of Silicagel For All Capacities And Ratings 207 Replacement Of Diaphram For Explosion Vent For All Capacities And Ratings 208 Replacement Of Cast Iron Wheel Valves For All Capacities And Ratings 209 Replacement Of Radiator Tubes, Fins : 210 ( A ) 16 / 25 / 40 Kva : 11 Kv 211 ( B ) 63 / 100 Kva : 11Kv 212 ( C ) 150 / 200 / 250 Kva : 11 Kv 213 ( D ) 500 Kva : 11 Kv 214 Replacement Of Damaged Lamination To Yoke: 215 ( A ) 16 / 25 / 40 Kva : 11 Kv 216 ( B ) 63 / 100 Kva : 11Kv 217 ( C ) 150 / 200 / 250 Kva : 11 Kv 218 ( D ) 500 Kva : 11Kv 219 Replacement Of Core Clamp Per / Each : 220 ( A ) 16 / 25 / 40 Kva : 11Kv 221 ( B ) 63 / 100 Kva : 11Kv 222 ( C ) 150 / 200 / 250 Kva : 11Kv 223 ( D ) 500 Kva : 11Kv 224 Replacement Of Oil Guage Glass With Gasket For All Capacities And Ratings

Key Value

Document Fees
INR 250 /-
EMD
INR 50000.0 /-
Tender Value
INR 50 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail