Provision Of Deficient Married Accommodationat Trv Chicolna Goa -Internal Water Supplys & F Two Way Bib Tap 15 Mm Complete All As Specified And Directed. Make -Drizzel Or Prayag Or Equivalent 16 S & F Health Faucet With Wall Hook Complete All As Specified And Directed. Make Hindware Model No F160027 Or Equivalent 17 Internal Electric Supply: S & F Bee Energy Efficient Bldc High-Speed Ceiling Fan Having 1200 Mm Blade Sweep, Air-Flow Not Less Than 210 Cmm, Operating Voltage 220-240 V And Frequency 50 Hz, Including A Down Road Of Suitable Size And Electrical Connection With 3 Core Flexible Cu Conductor Cable Of Appropriate Size From Ceiling Rose To The Fan Complete All As Specified And Directed. 18 S & F Energy Efficient Non-Metallic Fresh Air Fan Having Blade Sweep 250 Mm, Air Delivery Not Less Than 860 Cmh, Operating Voltage 220-240 V And Frequency 50 Hz, Including Electrical Connection With 3 Core Flexible Cu Conductor Cable Of Appropriate Size From Ceiling Rose To The Fresh-Air Fan Complete All As Specified And Directed. Make: Crompton Cat-Part No. Ventilus 10 Or Equivalent Model Of Usha, Havells Or Bajaj 19 S&F Engery Efficient Metalic Exhaust Fan Having Blade Sweep 300 Mm, Air Delivery Not Less Than 900 Cmh, Operating Voltage 220-240 V And Frequency 50 Hz, Including Electrical Connection With 3 Core Flexible Cu Conductor Cable Of Appropriate Size From Ceiling Rose To The Fresh-Air Fan Complete All As Specified And Directed.Make: Crompton Cat-Part No.Trans Air 12 Or Equivalent Model Of Usha, Havells Or Bajaj 20 S & F Rcbo Conforming To Is 12640 ( Part 2 ) : 2016, Assembled For Ac Applications Having Front Face Indication For Earth Leakage Fault, Sliding Shutters, Ip 20 Protected 35 Mm² Terminals, Colour Coded On / Off Indication On Dolly, Integrated Label Holder, Etc Complete All As Specified And Directed.63 A, 100 Ma, Fp 415V, 50 Hzrcbo 21 Supply, Installation, Testing And Commissioning Of Factory Made, Cpri Type Tested, Indoor Cubical Compartmental Type Lt Panel Of Suitable Size, Conforming To Iec 61439-1 & 2 And Iec 61641, Having Both Sides Open Able With Hinged Double Doors And Locking Arrangement, Ip 43 Protection Made Out Of 2.0 Mm Thick Mild Steel Crca Sheet, Supported And Fixed On Structural Frame Of Angle Iron Of Suitable Size, Including Earthing Stud, Labeling, Painting To All Internal & External Exposed Steel Surfaces With Powder Coating Paint ( 7 Tank Process ) , Duly Fixed In Ground With Pcc Foundation ( 1:2:4 ) Type B1, With Danger Notice Plate Of 1.6 Mm Thick Mild Steel Vitreous Enameled ( White ) With Letters, Figures And Conventional Skull And Bones In Signal Red Colour Suitable For 3- Phase, 4 Wire System, 500 V Grade With Necessary Wiring, Pvc Sheathed Stranded Copper Conductor Of Appropriate Length And Size, Including Fixing Lugs, Bolts, Screws, Etc. Complete All As Specified And Directed By Engineer-In-Charge. ( Building Supply At Ground Floor ) Thepanel Shall Comprise Of The Following: [ A ] Busbar Chamber [ I ] 01 Set ( 3L + N ) Of Copper Busbar Of Rated Capacity 400 A, Covered With Pvc Insulated Sleeves Including Insulator, Nuts, Bolts, Etc. With Complete Connection [ B ] Incoming [ I ] 250 A, 415 V, Ices = 100% Ice = 50 Ka, 50 Hz Fp Mccb, Conforming To Iec 60947-2, Having Microprocessor Based Trip Unit, Adjustable Overload Setting ( 0.7 - 1 X In ) , Adjustable Short-Circuit Setting ( 5 - 10 X Ire ) , Adjustable Neutral Protection ( N, N / 2, Off ) , Front Indication Leds ( Ready, Overload And Pre-Alarm & Overload ) , Etc. 22 [ Ii ] Led Phase Indicators ( Red, Yellow, Blue ) - 01 Set [ Iii ] Digital Multifunction Meter With Kwh And Karsh, Voltage, Current, Pf Functions [ C ] Outgoing [ I ] 63 A, 415 V, Ices = 100% Ice = 50 Ka, 50 Hz Fp Mccb, Conforming To Iec 60947-2, Qty 11 Nos [ Ii ] 20 A, 230 V, 50 Hz Spn Mcb, Conforming To Iec 60947-2, Qty 1 Nos ( For Lift Room ) [ Ii ] 6 A, 230 V, 50 Hz Sp Mcb, Conforming To Iec 60947-2, Qty 2 Nos ( For Common Light Points ) 23 Supply, Installation, Testing And Commissioning Of 1-Phase, 2-Wire, 240V, Class 1.0 Smart Energy Meter, Bis Marked Is-16444, At The Rating Of 5-30A Suitable For Prepaid / Postpaid Mode Withpolycarbonate Meter Box. The Smart Meter Shall Support The Following Minimum Basic Features: Measurement Of Electrical Energy Parameters; Bidirectional Communication; Integrated Load Limiting / Connect / Disconnect Switch; Tamper Event Detection; Recording And Reporting; Power Event Alarms; Remote Firmware Upgrade; Tod Features; On Demand Reading. Meter Shall Have The Ability To Communicate With Head End System ( Hes ) On Rfcommunication Technology Mentioned In Is16444 Part 1 In A Secure Manner. Data Exchange Protocol From Smart Meter To Hes Shall Be Based On Open Protocol Like Tcp / Lp Or Dlms / Cosem. Rf Network Should Use 865-867 Mhz Frequency Band As Permitted By Wpc. 24 Supply, Installing, Testing & Commissioning Of Cloud-Hosted Multiuser Web-Based Software With 2-Years Defect-Liability Period With Following Modules: ( I ) Head End System ( Hes ) : To Acquire Meter Data Automatically From Dcus And Monitor Parameters Acquired From Meters. ( Ii ) Meter Data Management Modules : The Meter Data Management Module Would Be Responsible For Collecting The Data From The Concentrator And Make The Data Available To The Billing System. The Meter Data Management System Would Capture And Provide The Following Data. ( A ) 30Min Instantaneous Data From All The Meters For Seven Parameters - Cumulative Energy , Power, Current , Voltage, Power Factor And Frequency. ( B ) Monthly And Quarterly Billing Survey Data For Cumulative Energy And Max Demand. ( Iii ) Billing Module : The Billing Module Would Collect The Data From The Meter Data Management Module, Calculate Billing Determinant And Make Energy Data / Billing Data Available To Admin And End User. There Should Be Provision For Entry Of Change In The Tariff Structure By The Mes Staff As Decided Time To Time. ( Iv ) Occupation And Vacation Module: The System Would Supportoccupation / Vacation Based On The Unit Categories. ( V ) Website: There Would Be A Dedicated Website For Age / Ge And Bsoteam To View All The Data And Information Along With Customer Portal For Use Of Customer. The Designated Users In Mes Would Have The Admin Access To The Application. The Mes Staff Would Also Have The Access To The Key Information On Mobile App ( Androi And Ios Based ) For Admin Use. ( Vi ) Customer Module : The System Would Include A Customer Portal For The Resident / Occupants To Log In And View Their Own Energy / Billing Data And Recharge Facility. There Shall Be Consumer App ( Android And Ios Based ) Also To Log In And View Their Own Energy / Billing Data And Recharge Facility. 25 ( Vii ) Communication Module : The System Would Provide Communication Of Energy Data And Bills Via Print, Email And Sms Methods. ( Viii ) Meter Master Data : The System Would Support Meter Datarepository. The System Would Support Meter Replacement Process. ( Ix ) Excel Export : The System Would Support Export Of Metering And Billing Data In Excel And Pdf Format. ( X ) Energy Accounting Module : The System Would Include Features Of Energy Accounting, The System Would To Able To Account For Total Energy Block Wise, Facility Wise And Would Also Allow Calculations Of The Unaccounted Energy In Case Total Energy Meter Is Also Available. ( Xi ) Prepayment / Recharging Facility: The System Should Periodically Monitor The Energy Consumption Of Prepaid Consumers And Decrease The Available Credit Based On The Consumption. The System Should Allow Online / Digital Recharging Through Consumer App ( Android And Ios Based ) And Web Portal. The Configuration And Necessary Arrangement For Payment Gateway And E-Mro Facility Shall Be Deemed To Be Included In The Quoted Rate. The System Should Send Connect / Disconnect Command On The Basis Of Available Credit. Low Credit Alarm: The System Will Give An Alarm Over The Consumer App And Sms To The Registered Mobile Number In Case The Credit In The Meter Goes Down Below A Predefined Limit. Emergency Credit: The Meter Will Work Even When The Credit Falls Down To Zero To Prevent Disconnection. This Limit Shall Be Configurable. The System Should Support Happy Hours In Order To Prevent Disconnection In Non-Working Hours And On Holidays. The Happy Hours Should Be Configurable. 26 Supply, Installation, Testing And Commissioning Of Dcus / Gateways And The Arrangement Of Sim Cards Or Internet To Enable Reliable Medium For Two-Way Communication Between Smart Meter & Hes. The Data Acquisition ( Push / Pull ) Frequency Shall Be Configurable. It Shall Push Events Such As Tamper, Power Off Etc. To Hes Immediately On Occurrence / Receipt From Meters. It Shall Have Provision For The Cellular, Wifi And Ethernet Communication For The Backhaul To Hes. It Shall Be Capable To Handle Data Of Minimum 1000 Nos. Of Any Type Of Smart Meter ( 1Ph / 3Ph ) . It Shall Be Able To Communicate With The Nearest Meters At A Distance Of At Least 500 M, Depending On Topographical Features. Communication Of The Nearest Meters With Other Meters Shall Be Established Through Appropriate Mesh Formation. Rf Mesh Shall Support Self-Forming And Self-Healing Features. The Equipment Shall Be Weather Proof And Dust Proof ( Minimum Rating: Ip54 For Indoor And Ip65 For Outdoor Installation ) . It Shall Have Rechargeable Battery With Backup For 1 ( One ) Hour For Normal Meter Reading, To Push Tamper Event, Carry Out On Demand Reading, Etc. 27 External Water Supply: Supply, Installation, Testing And Commissioning Pumping , Centrifugal Monoblock Electric Driven, 3 Phase, 415 Volts, ( 400 Lpm At 50M Head ) Including Necessary Pcc Foundation And Inlet & Out Water Supply Connection Including Provision Of Brass Gate Valve For Inlet And Outlet Connection Complete All As Specified & Directed. 28 Cutting The Existing Di Pipe Of 150 Mm Dia And Reducing To Required Length In Position For Inserting New Tees, Branches Etc. Complete All As Specified & Directed. 29 Supply And Lay Pipe Di , S / S Including Specials, Class K-7, 100 Mm ( 4 ) Dia. All As Specified & Directed. 30 Supply And Fix Foot Valve Conforming To Is 4038, 80 Mm Dia All As Specified & Directed. 31 Supply And Fix Strainer Y Type Conforming To Is, Size80mm Dia. All As Specified & Directed. 32 Supply And Fix Valve Reflux With By-Pass Arrangement, 80 Mm ( 3” ) Dia All As Specified & Directed. 33 M & L For Valve Chambers Suitable Upto 150 Mm Dia Bore Valves Of Size 90 Cm X 90 Cm X 90 Cm Complete With M S Cover All As Specified & Directed. 34 External Electric Supply:Supply And Fix Mccb With Sheet Metal Enclossure Capacity 250 A, 36Ka, 4 Pole All As Specified & Directed. 35 Supply Install Test And Commission Lt Panel Board, Tpn 415 Volts, 50 Hz, 300 Amps Capacity, Outdoor Cubical Type Floormountedfactory Made Double Doordust And Vermin Frooffabricatedout Of Crca Sheet Not Less Than 3.15 Mm Thickfixed On Angle Ironframemade Out Of 50X50x6 Mm With Cable Chamberfor Individual Feeders For Incommingand Outgoing Connections, One Set Of Indicator Lampryb With Switch And Fuse, Multifunction Intelligent Panel Meter Etc And With The Followings ( Main Bldg Panel ) Incoming:- ( A ) Multifunction Panel Meter With Cts ( B ) Mccb With Microprocessor Based Release, 4 Pole, 200 Amps, 50 Hz, 415 Volt, 35 Ka - 1 No ( Incoming ) Outgoings:- ( A ) Mccb, 4 Pole, 160 Amps, 50 Hz, 415 Volts, 35 Ka -01 Nos ( For Bldg ) ( B ) Mccb, 4 Pole, 63 Amps, 50 Hz, 415 Volts, 35 Ka -01 Nos ( For Dg Panel ) 36 Supply Install Test And Commission Lt Panel Board, Tpn 415 Volts, 50 Hz, 200 Amps Capacity, Oudoor Cubical Type Floor Mountedfactory Made Double Doordust And Vermin Frooffabricatedout Of Crca Sheet Not Less Than 3.15 Mm Thickfixed On Angle Ironframemade Out Of 50X50x6 Mm With Cable Chamberfor Individual Feeders For Incommingand Outgoing Connections, One Set Of Indicator Lampryb With Switch And Fuse, Multifunction Intelligent Panel Meter Etc And With The Followings :- ( Dg Panel ) Incoming:- ( A ) Mccb With Microprocessor Based Release, 4 Pole, 63 Amps, 50 Hz, 415 Volt, 35 Ka - 1 No ( Incoming ) Outgoings:- ( A ) Mccb, 4 Pole, 32 Amps, 50 Hz, 415 Volts, 16 Ka -01 Nos ( For Lift ) ( B ) Mcb, 4 Pole, 16 Amps, 50 Hz, 415 Volts, 16 Ka -01 Nos ( Domestic P / H ) ( C ) Mcb 3 Pole, 10 Amps, 50 Hz, 415 Volts, 16 Ka -02 Nos ( Street& Security Lights ) ( D ) Contactor 3 Pole 9 Amps ( Ac3 Rating ) Type Mx 9 Of L& T Cat Part No Cs94015-1 No ( E ) Analog Time Switch For 24 Hrs Setting 1 Phase, 15 Amps Of L&T Cat Part No Auts01ana00 - 01 No 37 Supply, Laying & Testing Pvc Insulated, Pvc Sheathed Cable Galvanized Steel Strip Or Wire Armoured, Electric Control Cables ( Heavy Duty ) With Stranded Copper Conductor Of Size 4Sq Mm, 3 Core, 1100 Volts Grade Complete All As Specified And Directed 38 Supply And Fix Prestressed Concrete Poles Of 9 Meter Long Having 152 Mm X 152 Mm At Top And 152 Mm X 260 Mm At Bottom, Including Excavation, Foundation And Coping Complete All As Specified And Directed 39 Supply And Fix Hot Press Moulded Smc Boxes With One No Mcb Sp 6 Amps, Connector 4 Way 16 Amps Including Fixing Clamps, Nut Bolts Etc Complete As Street Light Terminal Boxes All As Specified And Directed 40 Supply And Fix Aviation Obstruction Light All As Specified And Directed 41 Supply And Lay Pvc Insulated Pvc Sheathed Electric Control Cable With Stranded Copper Conductor Of Size 1.5 Sqmm 2 Core 1100 Volts Grade All As Specified And Directed 42 Fire Fighting: Supply And Lay Control Cable Pvc Insulated Pvc Sheathed Galvanised Steel Strip Or Wire Armoured With Stranded Copper Conductor Of Size 1.5 Sqmm2 Core 1100 Volts Grade All As Specified And Directed 43 Dg Set:Supply And Installation Of Silent Diesel Engine Driven Generating Set 415 Volts, 3Phase 4 Wire, Engine As Per Is:10001 / 10002 And Alternator As Per Is: 13364 Complete With Relay Panel And Switch Gears For Automatic Starting On Main Failure, Control Panel Having Meter And Sound Proof Canopy As Per Cpcb Norms And Foundation Etc. Of As Per Cpcb Norms And Foundation Etc. Of As Per Cpcb Norms And Foundation Etc. Of Capacity 30 Kva 44 Conduit For Tv: S&F Tv Socket With Metal Box And Top Plate Complete As Specified & Directed