Special Repair Of Equipment Shed No G 149, G 150, G 151 G 152 Of 140 Ad Regt And Provision Of Drainage From Offrs Mess Bldg No P 144 To Main Drain In B Area, Allenby Line Of Age Br I Under Ge ( South ) Ambala Cantt-Material And Labour For Brick Work With Sub Class ‘B’ Bricks, Straight Or Curved On Plain Exceeding 6 Metre Mean Radius In Cement Mortar ( 1:6 ) Including Demolition Of Brick Work Built In Cement Mortar Including Demolition Of Old Brick / Stone Masonry Built In Cement Mortar Of Any Description Including All Quoins, Archs, Pillars Etc Complete All As Specified And Directed. 2 Material And Labour For Brick Work ( Except Bricks ) Straight Or Curved On Plan Exceeding 6 Metre Mean Radius Built In Cm 1:6 ( Old Size Brick ) Including Demolition Of Old Brick Masonry Built In Cement Mortar Of Any Description Including All Quoins, Archs, Pillars Etc Complete All As Specified And Directed. 3 Taking Down Cement Plaster On Brick Or Stone Walls, Etc., Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And Directed. 4 Material And Labour For Rendering 15 Mm Thick On Any Faces Of Old Brick Work In Cement Mortar 1:6 Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 5 Material And Labour For Rendering 15 Mm Thick On Fair Faces Of New Brick Work Or Concrete Surfaces In Cement Mortar 1:4 And Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 6 Material Andlabour For Preparation Of Exposed Brick Wall Surface By Cleaning The Surface Wire Brush To Remove All Dirt / Loose Materials From The Bricks And From The Joints Between The Bricks. Prepared Surface Should Be Then Washed With Diluted Hcl Acid ( Dilution Ratio Of 1:50 ) For Three Times In A Day For Two Days. After Acid Wash Surface Should Be Allowed To Be Air Dried For One Day. Note : - Further Treatment Over The Surface So Achieved Will Be Carried Out Only After Approved Of The Same By Ge. 7 Material And Labour For Carrying Out Efflorescence Treatment To Unplastered Wall Surface Comprising Of The Following Specifications And Sequence With And Including 15 Mm Thick Rendering In Cm 1:4 Finished Even And Smooth Without Using Extra Cement : - ( A ) Prime The Prepared Surface With One Of The Following Product Mixed With Cement In 1:1 Ratio As Bonding Agent : - ( I ) Pidicrete Urp Of M / S Pidilite. ( Ii ) Sika Latex Of M / S Sika. ( Iii ) Nitobond Sbr Latex Of M / S Fosroc. ( B ) Immediately After Priming The Surface Pmm ( Polymer Modified Mortar ) To Be Applied “By Hand” While The Prime Is Tacky. Pmm Should Be Prepared By Mixing One Of The Following Compounds In Cement Mortar 1:3 As Per Manufacturer’S Instructions: - ( I ) Pidicrete Urp Of M / S Pidilite. ( Ii ) Sika Latex Of M / S Sika. ( Iii ) Nitobond Sbr Latex Of M / S Fosroc. ( C ) Pmm Surface Should Be Allowed To Dry For One Day. After That It Should Painted With Two Coats Of One Of The Following Compound Mixed With Cement Only In Ratio Of 1 ( Selected Compound ) : 1:5 ( Cement ) : - ( I ) Pidicrete Urp Of M / S Pidilite. ( Ii ) Sika Latex Of M / S Sika. ( Iii ) Nitobond Sbr Latex Of M / S Fosroc. ( D ) Now Apply Two Coats Of One Of The Following Compound Over The Surface. These Compounds Are To Be Used As Per Manufacturer’S Instructions: - ( I ) Pidifin 2K Of M / S Pidilite. ( Ii ) Brush Coat Of M / S Sika. ( Iii ) Brush Bond Of M / S Fosroc.Note : - Both Coats Should Be Perpendicular To Each Other And Gap Between Two Coats Shall Be Minimum 6 Hours. ( E ) Sprinkle Loose Coarse Sand After Second Coat While Surface Is Tacky.Note: - ( I ) The Item Will Be Executed By Authorized Applicator Only Of The Selected / Approved Company. Contractor Shall Submit Details Of Authorised Applicator For Approval Of Ge Before Commencement Of Work In Respect Of Above Item. ( Ii ) Every Stage Of Work Will Be Approved By Ge, Then Only Next Layer Will Be Executed By Contractor. 8 Material And Labour For Rough Cast Plaster With And Including 15Mm Thick Rendering In Cm 1:3 On Brick Wall Or Concrete Surface As Specified In Clause 14.22 Of Ssr Part-I Complete All As Specified And Directed.Note:- ( I ) After Applying The Under Coat Of Cement And Sand Mortar 1:3 Not Less Than 10 Mm Thick Andwhile It Is Still In Plastic State The Roughcast Mixture Consisting Of Crushed Stone Or Fine Gravelaggregate ( Which Is Generally Of Size Between 6 To 12 Mm Depending On The Texture Required ) Mixed With Coarse Sand And Cement In The Ratio Of 1: 1: 1 Shall Be Applied And Finished Even. ( Ii ) The Mix Of Cement And Sand Shall Be Made Slightly Wetter Than Normal For Rendering To Ensurethat Larger Aggregates Are Thoroughly Covered 9 Material And Labour For Preparation Of New Plastered Surfaces Of Walls And Applying Three Coats Of White Wash On Wall, Complete All As Specified And Directed. 10 Material And Labour For Preparation Of New Plastered Surfaces Of Wall And Applying Two Coats Of Cement Base Paint Over A Coat Of Alkali Resistant Primeron Walls Complete All As Specified And Directed. 11 Material Andlabour For Preparation Of New Plastered Surfaces Of Walls And Applying Two Coats Of Oil Bound Distemper With Hand Roller, Over A Coat Of Alkaline Resistant Primer Over A Coat Of Wall Care Puttynot Less Than 1Mm Thick As Per ManufacturerS Instruction Complete All As Specified And Directed. 12 Material Andlabour For Preparation Of Old Plastered Surfaces Of Walls And Applying Two Coats Of White Wash Complete All As Specified And Directed. 13 Material And Labour Preparation Of Old Plastered Surfaces Of Walls And Applying One Coat Of Cement Base Paint Complete All As Specified And Directed. 14 Supply Andfixing Of Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugatedsteel Sheet 0.50 Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa Tensile Strength As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws Or J Type Hooks Including Rubber Washer Etc Complete Including Dismantling Asbestos Cement Corrugated Or Semi-Corrugated Sheets Etc; Complete All As Specified And As Directed. 15 Supply Andfixing Of Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Galvanised Plain Mild Steel Sheeting 0.50 Mm Thick Of Any Colour, Having 550 Mpa Tensile Strength As In Roof Covering / Ridges And Fixed With Self Tapping Screws Or J Type Hooks Including Rubber Washer Etc Complete Including Dismantling Asbestos Cement Corrugated Or Semi-Corrugated Sheets Etc; Complete All As Specified And As Directed. 16 Dismantling Timber Scantling 40 Sq. Cm And Over In Section, In Any Position Of Unframed / Framed Work Complete All As Specified And Directed. 17 Material And Labour For Preparation Of Old Painted Steel Surfaces Of Any Description Not Otherwise Described, Over 10 Cm In Width Or Girth And Applying One Coat Of Synthetic Enamel Paint With Approved Shade Complete All As Specified And Directed. 18 Material And Labour For Taking Down Of Rolled Mild Steel Roof Trusses ( Framed ) Of Clear Span Above 08.00 Metre And Upto 12.00 Metre Any Type, Taking In Safe Costudy And Refixing The Same With And Including Using New Nut Bolts, Welding & Distance Pieces, Cleats Etc., After Completion Of Truss Connected Repair Work Etc Complete All As Specified Anddirected. Note: - Any Damage To The Existing Truss During Dismantling Or Refixing Etc, Shall Be Made Good By The Contractor With The Same Specifications As Per Existing Work, Without Any Extra Cost To The Govt. 19 Dismatling Of Mild Steel Beam, Purlin Of Existing Truss Andrefixing The Same ( Using Nut Bolt, Welding ) Rolled Mild Steel Plate Girder Or Single Stanchions, Built Up Of One Beam Or Channel Section With Flange Plates, Caps, Bases, Splices, Angle Brackets, Cleats & Other Connections Gde Fe410-0 Or Fe 310-O Complete All As Specified And As Directed. 20 Supply And Fixing Of Rolled Mild Steel Sections As In Main & Cross Beams, Hip & Jack Rafters; Purlins Where Connected To Common Rafters & Running Rails & Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Gde Fe410-0 Or Fe 310-O Complete All As Specified And As Directed. 21 Supply Andfixing Of Rolled Mild Steel Work In Roof Trusses ( Framed ) , Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing ( Beam, Tee, Angle, Channel Or Flat Sections ) Including Distance Pieces, Cleats Etc., Quality Confirming Tofe 410-W ( Gde E-250 ) Quality A, Complete, All As Specified And As Directed. 22 Supply Andfixing Of Mild Steel Plates ( Plain Or Chequered ) Channels, Square Cut Or Notched ( Ordinary And Counter Sunk ) Forming Holes, With Riveted, Bolted Or Welded Attachment Conforming To Grade Fe-410 ( Gde 250 ) , Complete All As Specified And Directed. 23 Material And Labour For Steel Screw Bolts, Machine Made, Dia Of Neck 11 To 15Mm With Hexagonal Or Square Head One End And Screwed The Other Or Screwed Both Ends, Each Screwed End To Be Fitted With Washer And One Hexagonal Or Square Nut Exceeding 22.5 Cm And Not Exceeding 30Cm Long, Complete All As Specified And Directed. 24 Material And Labour For Two Coats Of Synthetic Enamel Paint On Steel Surfaces Over A Coat Of Red Oxide Primerincludingpreparation Of New Steel Surfaces Of Any Description Not Otherwise Described Over 10 Cm Width Or Girth, Complete All As Specified And As Directed. 25 Material And Labour For Hardcore Of Gauge Not Exceeding 63 Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface Complete All As Specified And Directed. 26 Material And Labour For 150Mm Thick Pcc 1:2:4 Type B2 Using 40Mm Graded Mechanically Crushed Stone Aggregate As In Hardstanding / Paths, Finishing The Concrete Surface Even And Smoothwithout Using Extra Cement Including Formingjoints And Fillingwith Mixture Of Bitumen And Sand In Ratio ( 1:1 ) By Weight Including Necessary Formwork Etc And Including Demolition Of Existing Old Cement Concrete In Ground Floors And Pavings N.Exc 15Cm Thickness ( Below Or Above ) Ground Level Complete All As Specified And Directed. 27 Material And Labour For 50Mm Thick Pcc ( 1:3:6 ) Type C-1 Using 20Mm Graded Mechanically Crushedstone Aggregate As In Plinth Protection Finished Even And Smooth Without Using Extra Cement With & Including 10Mm Wide, 30Mm Deep Joints At The Rate Of 3.00 Mtr Centre To Centre And At Every Turning & Filling The Joints With Bitumen & Sand Mixture Including Demolition Of Cement Concrete In Ground Floor And Pavings Not Exceeding 15 Cm Below Or Above Ground Level Etc Complete All As Specified And Directed. 28 Surface Excavation Not Exceeding 30 Cm Deep, Averaging 15 Cm Deep And Getting Out In Soft / Loose Soil, Complete All As Specified And Directed. 29 Material And Labour For 100Mm Thick Pcc ( 1:4:8 ) Type D-2 Using 40Mm Graded Mechanically Crushed Stone As In Sub Base Of Floor / Hard Standing Finished, Complete All As Specified And Directed. 30 Material And Labour For Providing And Laying 80Mm Thick Factory Made Chamfered Edge Cement Concrete Paver Block Of M-40 Grade With Approved Colour, Design & Pattern As In Footparth, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc., Of Required Strength, Thickness & Size / Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over And Including 50Mm Thick Compacted Bed Of Fine Sand, Compacting And Proper Embedding / Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand; Complete All As Specified And Directed 31 Material And Labour For Providing And Laying Of Precast Pcc Solid Concrete Block, Grade - C Confirming To Is 2185 ( Part-I ) 2005 Of 45 Cm High, 10 Cm Thick And Of Suitable Width Including Chamfers, Weatherings, Throating Etc As In Kerb Continuous Edging Jointed In Cement Mortar 1:4 And Struck Flush Pointing As The Work Proceeds And Finishing With Neat Cement Flush Joint, Complete All As Specified And Directed. 32 Material Andlabour For Premium Quality, Joint Free, Non Skid Coloured Ceramic Tiles, Area Of Each Tile Exc 0.11Sqm But Not Exceeding 0.18 Sqm, 7 To 8 Mm Thick As In Floor, Set And Jointed In Neat Cement Slurry @ 3.00 Kg / Square Metre And Pointed In White Or Coloured Cement To Match The Surface Over And Including15mm Thick Screed Bed Or Layer In Cement Mortar ( 1:4 ) Including Dismantling Of Existing Tiles Etc Including Cement Mortar Bedding ( But Not Backing ) Andrubbish Off The Premises Complete All As Specified And Directed. 33 Material And Labour Forpremium Quality Coloured Glazed Ceramic Tiles ( 300X 450X 7Mmthick ) In Vertical Surfacesand Jointed In Neat Cement Slurry @ 3.00 Kg / Square Metre And Pointed In White Or Coloured Cement To Match Including Rendering 10Mm Thick In Cement Plaster 1:3 Including Dismantling Of Old Floor Or Wall Tiling Including Cement Mortar Bedding And Removing The Rubbish Outsidethe Defence Land Complete All As Specified And As Directed. 34 Material And Labour For Machine Cut Kota Stone Slab 20-25 Mm Thick ( Size Of Each Stone Not Less Than 55Cm X 55Cm ) , Laid In Flooring, Over And Including Cement Screed Bed 20Mm Thick In Cement Mortar ( 1:4 ) Base Set And Jointed In Neat Cement Slurry @ 3.00 Kg / Sqm And Pointed In White Or Coloured Cement To Match The Surface Mixed With Pigment To Match Shade Of The Slab Over And Including 25 Mm Thick Cement Concrete Type B-0, 1:2:4 ( 12.5 Mm Graded Aggregate ) As In Levelling Course, Including Cutting, Waste, Rubbing And Polishing ( Mirror Finish ) Including Dismantling Of Existing Stone Slab / Tiles Etc Including Pcc And Cement Mortar Bedding Andrubbish Off The Premises Complete All As Specified And Directed. 35 Material And Labour For Machine Cut Kota Stone Slab 18-20 Mm Thick ( Size Of Each Stone Not Less Than 55Cm X 55Cm ) , Laid On Vertical Surfaces Of Skirting / Dado, Over And Including Cement Screed Bed 15 Mm Thick In Cement Mortar ( 1:3 ) And Set And Jointed In Neat Cement Slurry @ 3.00 Kg / Sqm And Pointed In White Or Coloured Cement To Match The Surface Mixed With Pigment To Match Shade Of The Slab Including Cutting, Waste, Rubbing And Polishing ( Mirror Finish ) Including Dismantling Of Existing Stone Slab / Tiles Etc Including Cement Mortar Bedding ( But Not Backing ) Andrubbish Off The Premises Complete All As Specified And Directed. 36 Supply And Fixing In Repair Of 5.5Mm Thick Looking Mirror Of Selected Quality, Beveled Edge 450Mmx600mm Glass Mounted On 6Mm Thick Ac Building Board With Aluminiumbeading Andrubber Packing And Fixed To Wall With Wooden Plug With Chromium Plated Brass Screw And Cup Washer Complete All As Specified And Directed. 37 Supply & Fixing ( In Repair ) Vitreous China Wash Down Water Closet Pedestal Pattern ( Ewc ) , White Including Connection To Trap And To Flushing Pipe With ‘P’ Or ‘S’ Trap, Making Good To Floor, Plastic Water Closet Seat Cover With Mild Steel Chromium Plated Hinges And Chromium Plated Jet Spray With 1.5 Meter Flexible Ldpe Pipe Jointed With Pipe Complete All As Specified And Directed. 38 Supply And Fixing In Repair Of Health Faucet With 8Mm Dia, 1Metre Long Flexible Tube And Wall Hook Complete All As Specified And Directed. 39 Supply & Fixing In Repair Of Vitreous China Wash Hand Basin White Flat Back Of Size 550X440mm Including Ci Brackets And 15Mm Chromium Plated Pillar Tap, Pvc Connection 450 Mm Long Having Ptmt Nuts And 32 Mm Dia Brass Chromium Plated Waste Coupling And Making Good To Disturbed Portion Including32 Mm Dia Pvc Waste Pipe Etc., Complete All As Specified And Directed. 40 Supply And Fixing In Repair Of 10 Litre Capacity Virgin Polypropylene Cistern, White, Isi Marked, Coloured At Low Level Complete Including Supply And Fixing45 Cm Pvc Connection, Pvc Bend / Flush Pipe Andmaking All Connection , And Removal Old Complete All As Specified And Directed. 41 Supply And Fixingin Repair Of Vitreous China Half Stall Urinal Complete Including Providing And Fixing Plugs, Bedding Urinal Against Wall In Cement Mortar 1:2, Securing Urinal To Plugs With And Including 60 Mm Long Brass Screws, Pointing Around Urinal Back In Cement, Pvc Waste Pipe, Flush Pipe, Cp Waste Fitting, Grating And Union For Discharge Pipe Complete All As Specified And Directed. 42 Supply And Fixing In Repair Of Cp Bib Tap Screwed Down High Pressure, Long Body, Cast Copper Alloy, Chromium Plated With Crutch Or Butterfly Handles Screwed Down Suitable For 15Mm Bore Pipe Or Union, Complete All As Specified. ( Note : Weight Of Bib Tap Shall Not Be Less Than 0.575 Kg ) 43 Supply And Fixing Of Gi Tubing, Isi Marked, 15Mm Bore, `Medium Grade, With All Fittings And Fixed Complete To Walls And Ceilings Or Laid In Floors Including Necassary Cutting / Chasing / Pinning In Wall And Making Good The Disturbed Surfaces As Per Existing Whereever Required, Including Taking Down Of Old Tubing As Existing At Site And Removal, Complete All As Specified And As Directed. 44 Supply And Fixing Of Gi Tubing, Isi Marked, 20Mm Bore, `Medium Grade, With All Fittings And Fixed Complete To Walls And Ceilings Or Laid In Floors Including Necassary Cutting / Chasing / Pinning In Wall And Making Good The Disturbed Surfaces As Per Existing Whereever Required, Including Taking Down Of Old Tubing As Existing At Site And Removal, Complete All As Specified And As Directed. 45 Refixing Old Serviceable Steel Water Tubing Of 15 Mm Bore, In New Or Old Position, Any Grade, Including S&F New Fittings As Required, Fixed To Walls And Ceilings Or Laying In Floors Including Necassary Cutting / Chasing / Pinning In Wall And Making Good The Disturbed Surfaces As Per Existing Whereever Required , Including Taking Down Of Old Tubing As Existing At Site And Removal, Complete All As Specified And As Directed 46 Refixing Old Serviceable Steel Water Tubing Of 20 Mm Bore, In New Or Old Position, Any Grade, Including S&F New Fittings As Required, Fixed To Walls And Ceilings Or Laying In Floors Including Necassary Cutting / Chasing / Pinning In Wall And Making Good The Disturbed Surfaces As Per Existing Whereever Required , Including Taking Down Of Old Tubing As Existing At Site And Removal, Complete All As Specified And As Directed 47 Supply And Fixing In Repairs, Water Storage Tank Of 500 Ltr Capacity, Hdpe Double Layer, Isi Marked, Fixed And Hoisted In Position On Staging Or Roof Complete With Locking Arrangement Including Over Flow Pipe, Air Lock Pipe, Brass Valve 20 Mm High Pressure With Polythene Float And Flynut, Isi Marked, Screwed Andsuitable For Iron Pipe 20 Mm Bore Complete All As Specified And Directed. Note:- Make Of Tank Shall Be Engraved On The Tank. 48 Supply Andfixing In Repair Of Angle Valve, 15Mm Dia Chromium Plated, Cast Copper Alloy, Screwed Down, High Pressure With Capstain Head, Heavy With Adjustable Wall Flange, And Removal Old Complete All As Specified And Directed. 49 Supply & Fixed In Repair Of Stop Cock, Fancy Type, Chromium Plated, Long Shank And Cup ( Concealed Type ) Screwed Down High Pressure With Crutch Or Butterfly Handle Screwed Both Ends Suitable For 15Mm Bore Pipe, Complete All As Specified And Directed. ( Note : Weight Of Stop Cock Shall Not Be Less Than 0.575 Kg ) 50 Supply And Fixingin Repair Of Chromium Plated Shower Rose With Swivel Joints And Including Fixed To Gi Tubing 15Mm Bore Size Of Shower Not Less Than 125Mm Complete All As Specified And Directed. 51 Supply And Fixing In Repair Of Chromium Plated Soap Dish With Fitting Fixed With Brass Screws Complete All As Specified And Directed. 52 Supply And Fixing In Repair Of 20 Mm Dia Gun Metal, Globe Or Gate Valve With Iron Wheel Head Screwed Both Ends For Iron Pipe And Fixed Complete All As Specified And Directed. 53 Supply Andfixing In Repair Of Brass Chromium Plated Tubular Towel Rail, 20 Mm Dia, ‘D’ Type 60 Cm Long Between Flanges Complete All As Specified And Directed. 54 Excavating In Trenches, Not Exceeding 1.50 M Wide & Not Exceeding1.5M Depth & Getting Out In Hard / Dense Soil Complete All As Specified And Directed. 55 Supply And Fixing Of Pvc ( Swr ) 75 Mm Pipe Single Socket In Any Length With Rubber Ring Joints Laid In Floor Or Trenches Includingdismantling Ofpipes Of Any Description Any Length Etc Complete All As Specified And As Directed. 56 Supply And Fixing Of Pvc ( Swr ) 110 Mm Pipe Single Socket In Any Length With Rubber Ring Joints Laid In Floor Or Trenches Includingdismantling Ofpipes Of Any Description Any Length Etc Complete All As Specified And As Directed. 57 Supply And Fixing Of Pvc ( Swr ) 110 Mm Pipe Single Socket In Any Length With Rubber Ring Joints Fixed To Wall With Ms Clamps Including Dismantling Ofpipes Of Any Description Any Length Etc Complete All As Specified And As Directed. 58 Supply And Fixingin Repair Of 110 Mm Bore Pvc ( Swr ) Bend With Access Door Including Jointing With Solvent Cement, Complete All As Specified And Directed. 59 Supply And Fixingin Repair Of Pvc ( Swr ) 110 Mm To 75 Mm Dia, Reducers Complete All As Specified And Directed. 60 Supply And Fixing In Repair Of 110 Mm Bore Pvc ( Swr ) , Junction Single T ( Equal Or Unequal ) , Including Jointing With Solvent Cement, Complete All As Specified And Directed. 61 Supply And Fixing In Repair Of Pvc ( Swr ) Floor Trap 75Mm Dia Plain With Pvc Grating Including Jointing With Solvent Cement Complete All As Specified And Directed. 62 Taking Down Chowkats Or Frames With Shutter, Areanot Exceeding 1.50 Square Metre ( W / O Taking Off Shutters From Frames ) And Removing From Site, Including Cutting Holes In Wall / Concrete For Taking Out Existing Hold Fasts And Making Good The Disturbed Portion Of Jambs Andadjoining Surfacesin Cm ( 1:3 ) And Finishing The Surfaces To Match With Existing Finish Complete All As Specified And Directed. 63 Taking Down Chowkats Or Frames With Shutter, Areaexceeding 1.50 Square Metrebut Not Exceeding 4 Square Metre ( W / O Taking Off Shutters From Frames ) And Removing From Site, Including Cutting Holes In Wall / Concrete For Taking Out Existing Hold Fasts And Making Good The Disturbed Portion Of Jambs Andadjoining Surfacesin Cm ( 1:3 ) And Finishing The Surfaces To Match With Existing Finish Complete All As Specified And Directed. 64 Supply And Fixing Of Pressed Steel Frames For Doors Of Size 125 X 60Mm, 1Mm Thick, With One Or More Rebates Including, Hold Fasts Of 25Mm X 4Mm Fi, 25Cm Long, 6 Nos In Each Chowkhat, Necessary Lugs, 3 Nos 100 Mm Ms Butt Hinges Medium Weight, Cold Rolled, Welded For Each Shutters Of Frame, Lock Strike Plate, Including Sanding, Tarring Backs Of Chowkhats, Pcc 1:3:6 Type C-0Filling In Frame And For Holdfast, 2 Nos 12 Mm Dia Ms Tie Bars At The Bottom Of Frame And One Shop Coat Of Red Oxide Primer Etc Complete All As Specified And As Directed. 65 Supplyand Fixing Of Factory Made 35 Mm Thick, Second Class Hard Wood Rail And Style, Plain Framed, Panelled Shutter ( Two Panel ) With Lock Rail And Panel Of 9 Mm B.W.P Commercial Ply Or 12 Mm Veneered Particle Board With Commrcial Veneering On Both Faces Ace, Size Of Rails And Stiles Asper Is 1003 ( Part-I ) Kiln Seasoned And Chemical Pressure Treated Complete All As Specified And Directed. 66 Supply And Fixing Of Iind Class ( Hollock ) Factory Made 35Mm Thick Glazed Skelton Door Shutters, Open Rebated And Prepared To Receive Glass, Gauge Etc. Divided Into Squares Edges Of Framing, Plain, Chamfered Or Rounded, Mitred Fitted With Cut And Mitred Beads For Securing Glass / Gauge Etc. With Sizes Of Members Of Shutters As Specified In Para 8.24 ( A ) Of Ssr 2009 ( Part I ) , Complete All As Specified And Directed. 67 Supply And Fixing Factory Of Made Pvc Hollow Door Frame Of Size 50Mm X 47Mm With Wall Thickness Of 5 Mm Made Out Of Extended 5 Mm Rigid Pvc Foam Sheet Cut At Corner And Jointed With 02 Nos, 150 Mm Long Brackets Of Size 15 Mm X 15 Mm Mild Steel Square Tubes 19 Gauge Including Vertical Door Profiles Reinforced With 19 Mm X 19 Mm Steel Square Tube Of 19 Gauge ( Epdm ) Rubber Gasket Weather Seal Provided Through Out The Frame And Fixed To Wall With 65 / 100 Mm Long Mild Steel Screws Through The Frame By Using Pvc Fasteners ( Minimum Of 04 Nos Of Screws To Be Provided For Each Vertical Numbers & Minimum 02 Nos For Horizontal Member ) Complete All As Specified And Directed. 68 Supply Andfixing Factory Made Solid Pvc Moulded Door Shutter, 28 To 30 Mm Thick ( Stiles ) With 2, 4 Or 6 Raised Panel Design With 2 Mm Thick Moulded Pvc Sheet On The Front Face & 2 Mm Plain Colour Pvc Sheet On Back Face Includingfixing In Frame At Site With 03 Nos Ss Hinges, 02 Nos Aluminium Tower Bolt 150 Mm, 02 Nos Aluminium Handle 150 Mm For Each Shutter All As Per Specification & Drawing Complete All As Specified And Directed. 69 Supply And Fixing In Repair Of Steel Window Box Type Using Erw Hollow P Section Comprising Double Frame For And Including Gauged And Glazed Skelton Shutter 30Mm Thick, Jointed Internally With Flat Iron 25X3mm Complete Including Hinges, Handle, Tower Bolts, Stops, Lugs Etc. All As Shown On Drawing No. Td-219 ( C ) Sheet 1 / 3 To 3 / 3 And Td-220 ( C ) Sheet 1 / 3 To 3 / 3 As Applicable Including Pcc ( C-O , 1:3:6 Using 12.5 Graded Agg ) Bed Blocks For Hold Fasts And One Shop Coat Of Red Oxide Primer Etc Complete All As Specified And Directed.Note: ( I ) For The Purpose Of Measurement & Payment Double Shutter With Frame Shall Be Considered As One Unit. ( Ii ) Unit Rate Quoted Against This Item Shall Also Include The Iron Mongery , Grills 10Mm Square Bars. ( Iii ) Only Glazing, Wire Mesh & Painting Grill Shall Be Measured & Paid For Separately ) 70 Supply And Fixingin Repairs Of Mild Steel Ventilator Of Section Framed Fixed Type And Fixed Wire Mesh With Flat Bends 10 Mm X 3 Mm With Nuts / Bolts Complete Including Fixing Lugs, Necessary Pcc 1:3:6 Type C-1 For Filling Bed Blocks Of Hold Fasts / Lugs, Etc Complete All As Specified And Directed. 71 Supply And Fixing Of Mild Steel Pressed Handle, 150Mm Long, Oval Type, Stove Enameled Black, Complete All As Specified And Directed. 72 Supply And Fixing Of Mild Steel Barrel Tower Bolt Stove Enamelled Black With Bright Bolt 200Mm Long Complete All As Specified And Directed. 73 Supply And Fixing Of250 Mm Long Mild Steel Sliding Door Bolts , Plate Type, Stove Enamelled Black, With Bright Bolt Not Less Than 12Mm With And Including A Minimum Of 6 Bolts And Nuts , Four On Bolt Plate And Two On Staple Plate Complete All As Specified And Directed. 74 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc. 25 Cm Thick In Soil Complete All As Specified And Directed. 75 Removing Surplus Excavated Material ( Soil ) To Distance Not Exc. 50 M And Depositing Where Directed At A Level Not Exc. 1.50 M Above The Starting Point Complete All As Specified And Directed. 76 Material And Labour For Pcc 1:3:6 Type C-2 Using 40Mm Graded Mechanically Crushed Stone Aggregate As In Foundation Filling, Mass Concrete, Sub Base Etc. Complete All As Specified And Directed 77 Material And Labour For Plain Cement Concrete 1:2:4 Type B-1 ( Using 20Mm Graded Mechanically Crushed Stone Aggregate ) As In Surface Channels And Drains, Complete All As Specified And As Directed. 78 Material And Labour For Pcc 1:2:4 Type B-1 ( Using 20 Mm Graded Mechanically Crushed Stone Aggregate ) Ascopings, Bed Plates, Kerbs, And Other Bands And The Like, Finished The Surface Fair Andeven, Including Necessary Form Work Etc Including Demolition Of Existing Cement Concrete Of Any Description And In Any Position Complete All As Specified And Directed. 79 Material And Labour For Providing And Laying Of Precast Cement Concrete Solid Concrete Block, Type B-1, 1:2:4 ( Using 20Mm Graded Stone Aggreagate ) Confirming To Is 2185 ( Part-I ) 2005 Of 30 Cm High, 10 Cm Thick And Of Suitable Width Including Chamfers, Weatherings, Throating Etc As In Kerb Continuous Edging Jointed In Cement Mortar 1:4 And Struck Flush Pointing As The Work Proceeds And Finishing With Neat Cement Flush Joint Etc Complete All As Specified And Directed. 80 Dismantling / Taking Down Carefully Aluminium / Copper Point Wiring ( Light, Fan, Socket Or Power ) Complete, Including Fixtures And Fittings Such As Switches, Ceiling Roses, Pendants, Regulators , Sockets, Light Fittings Etc., Removing Materials To Stores For Keeping In Safe Custody For Taking Credit And Making Good The Disturbed Surfaces Of Wall, Floors, Ceiling Etc To Match With The Existing Surfaces With Matching Obd / White Wash / Distemper Complete All As Specified And As Directed. 81 Material And Labour For Concealed Point Wiring With 1.50 Sqmm Single Core Pvc Insulated, Unsheathed Cable Frlsh, 1100 Volt Grade With Multi Stranded Copper Conductor Drawn Through And Including Medium Grade, Isi Marked, Pvc Conduit Not Less Than 25 Mm Dia With Frlsh Accessories, Concealed And Including Provision Of 1.50 Sqmm Single Core Pvc Insulated, Unsheathed Cable Frlsh 1100 Volt Grade With Multi Stranded Copper Conductorgreen Colour As Earth Continuity Conductor And Connected To Common Earth Dolly With Suitable Size Of Lugs, Including Mild Steel Sunken Box Or Pressed Steel Terminal Boxes Made Out Of 1.6 Mm Thick Mild Steel Sheet Metal Conforming To Is-5139 ( Pt-I ) Of 1969 And Is:14772-2000 With Earth Dolly And Coated With Two Coats Of Anti Corrosive Paint Over A Coat Of Red Oxide Primer Bothinternally And Externally Including Provision Of New 3 Mm Thick Plastic Laminated Sheet Top Cover Extended Up To 25 Mm Over Sunken Box For Housing The Switches , Socket Outlets, Fan Regulators Etc. With Brass Screws And Brass Washersand Making Goodthe Disturbed Surfaces As Per Existing For One Light / Fan Point / Bell Point Controlled By One Switch Complete All As Specified And Directed. Notes : - ( I ) The Quoted Rates Shall Be Deemed To Be Inclusive For Cutting Chases By Chase Cutter In Wall / Pillars / Columns Etc. Of Any Description For Concealing The Conduits To Required Depth & Making Good The Disturbed Surface In Cement Mortar 1:4 Including Finishing The Surface To Match With The Existing Surface. The Portion Of Point Wiring At Ceiling Shall Be In Surface Conduit Of Suitable Size Fixed On Ceiling Surface With Using Necessary Accessories / Fittings. ( Ii ) Point Wiring & Earth Wire Shall Be Connected To Each & Every Flush / Sunken Box. ( Iii ) All Screws, Fasteners, Bolts, Nuts & Washer Shall Be Cadmium Plated & The Cost Of Which Is Deemed To Be Included In The Quoted Unit Rates. 82 Description All As Per Item No 81.00 Above But For Socket Out Let Point 5 Amps On Same Board Complete All As Specified And Directed. 83 Description All As Per Item No 81.00 Above But For Socket Out Let Point 5 Amps On Independentboard Complete All As Specified And Directed. 84 Description All As Per Srl Item No 81.00 Above But Point Wiring For One Socket Out Let 15&5 Amps ( Independent ) Controlled By One Switchwith Using 2.5 Sq Mm ( Nominal Area ) Stranded Copper Conductor Complete All As Specified And Directed. 85 Supply And Fixing Of Switch Piano 6 Amps, Flush Type, Single Pole, One Way, 230 Volt , Ac Supply, Isi Marked, Complete All As Specified And Directed. 86 Supply And Fixing Of Switch Piano 15 Amps Flush Type One Way 230 Volts, 50 Hz, Ac Supply, Isi Marked, Complete All As Specified And Directed. 87 Supply And Fixingsocket Outlet 3 Pin 5 Amps, 230 Volts Flush Type , Isi Marked, Complete All As Specified And Directed. 88 Supply And Fixing Of Socket Outlet 2 In 1, 6 / 16 Amps, 5 Pin 230 Volt Flush Type, Isi Marked Complete All As Specified And Directed. 89 Supply And Fixing Of Ceiling Rose Surface Bakelite 65X50mm, 3 Terminal Complete All As Specified And Directed. 90 Supply And Fixing Offan Regulator Electronic Step Type , 230 Volts, Ac Supply, Suitable For Ceiling Fan Any Type / Make / Sweep, Complete All As Specified And Directed. 91 Supply And Fixing Lamp Holder, Pvc / Polycarbonate Type With Back Plate Suitable For Batten Fittings, Complete All As Specified. 92 Supply And Fixing Of Led Lamp 9 Watt Suitable For Batten Holder Complete All As Specified And Directed 93 Supply And Fixing Of Double Stiff Pendants, Comprising Of Galvanised Steel Or Chromium Plated Brass Bell Mouth Connectors 2 Nos. With Back Plate And 2×1.50 Metre Long Parallel 20Mm Dia Galvanised Or Stove Enamelled Screwed Steel Conduit With Two Check Nuts For Fixing Tube Light Fitting And Upto 1.5 Metre Long Twin Core 0.5 Sq. Mm Copper Conductor Flexible Wire / Cable Including Disconnecting And Taking Down Old Existing Light Fitting Of Any Description And In Any Position Complete All As Specified And Directed. 94 Supply And Fixing Of Industrial Box Channel For Fixing Of Led Tube Rod, In Crca Body Suitable For 2X18 / 20 Watt Led Tube, High Efficient, Ac 220-240 Volts, 50 Hz And Connecting With Copper Conductor Flexible Cable Of Size 0.50 Sqmm From Ceiling Rose To Connector Of The Light Including Disconnecting And Taking Down Old Existing Light Fitting Of Any Description And In Any Position Complete All As Specified And Directed. Note : - ( I ) Tube Rod Shall Be Measured And Paid For Separately. ( Ii ) Channel Must Be Get Approved From Engr In Charge To Check Fesibilty I.E. One End Contact Or Two End Contact. 95 Supply And Fixing Of Channel For Fixing Of Led Tube Rod, In Crca Body Suitable For 18 / 20 Watt Led Tube, High Efficient, Ac 220-240 Volts, 50 Hz And Connecting With Copper Conductor Flexible Cable Of Size 0.50 Sqmm From Ceiling Rose To Connector Of The Light Including Disconnecting And Taking Down Old Existing Light Fitting Of Any Description And In Any Position Complete All As Specified And Directed. Note : - ( I ) Tube Rod Shall Be Measured And Paid For Separately. ( Ii ) Channel Must Be Get Approved From Engr In Charge To Check Fesibilty I.E. One End Contact Or Two End Contact. 96 Supply And Fixing Of 18 W / 20W Polycarbonate Led Tube Light, Environment Friendly, High Efficient, T8 With Aluminium Extrusion Heat Sink For Optimum Performance With High Luminous Efficiency And Easy And Taking Down Existing Tube Light And Removal Complete All As Specified And Directed. Note: - Tube Rod Must Be Get Approved From Engineer In Charge To Check Fesibilty I.E. One End Contact Or Two End Contact For Fixing In Existing Led Fittings. 97 Supply And Fixing Ofbulk Head Light Fitting, 15 Watt, Energy Efficient Withlamp 15 Watt With Provision Of 2 / 3 Core Pvc Copper Conductor Cable 0.5 Sqmm Size From Ceiling Rose To Light Fitting Completeincluding Disconnecting And Taking Down Old Existing Light Fitting Of Any Description And In Any Position Complete All As Specified And Directed. 98 Supply And Fixing In Repair Bracket For Security Light Made Up Of 25Mm Dia, 0.9 Metre Long Gi Pipe, Light Grade, Bent To Required Length, Fixed To Wall With Two Clamps Made Of 20 X 3 Mm Mild Steel Flat Minimum 15Cm Long, 4 Nos 8Mm Dia Bolts With Nuts Complete All As Specified And Directed. 99 Supply And Fixing Led Security Light Luminaire 50 Watt , Pressure Die Cast Aluminum Housing, Toughened Heat Resistant Glass, Ip65 Protection, Better Optics For Uniform Distribution With Multiplte Leds Not Less Than 2 W Each And Having Optical Grade Polycarbonate Lens With All Accessories Internally Pre Wired And Including Connecting Up With Two Core 1.5 Sq Mmcopper Conductor Cable From Connector To Ceiling Rose To Connection Of Light Including Disconnecting And Taking Down Oldunserviceable Security Light Fitting Of Any Description And In Any Position Complete All As Specified And Directed. 100 Supply And Fixing Led High Efficient Bay Light 50 Watt, Die Cast Aluminum Housing, Toughened Heat Resistant Glass, Ip66 Protection, Better Optics For Uniform Distribution With All Accessories Internally Pre Wired And Including Connecting Up With Two Core 1.5 Sq Mmcopper Conductor Cable From Connector To Ceiling Rose To Connection Of Light Including Disconnecting And Taking Down Oldunserviceable Security Light Fitting Of Any Description And In Any Position Complete All As Specified And Directed. 101 Supply And Fixing Of Sheet Metal Enclosures Vertical Distribution Board Vtpn, ( Mccb Db ) 4 Ways, Double Door, 415 Volts With 200 Amps Rated Bus Bar Ip 54 Protection, With Shrouded Neutral Bar And Insulated Bus Bar And Earth Link, With And Includingmccb 4 Pole Thermal Release Type, 100 Amps, 16 Kaas Incomer And Mcbsas Out Going Complete With Making Suitable Size Of Ms Cabinet 2 Mm Thick Dully Grouted On The Wall ( Flush ) With Opening Arrangement Including Making Connections With Suitable Size Of Lugs / Thimbles / Glands And Making Good The Disturbed Surface Matching With Existing Surface Including Taking Down Existing Unserviciable Mccb / Dbs Including Mcbs Complete All As Specified And Directed. 102 Supply, Installation, Testingofspn Distibution Board 8 Way, Double Door , Ip 43, As Per Is 8623Including 200 Amps Fully Insulated Copper Bus Bar, Insulated Neutral Bar, Earth Bar, Door Earthing, Reversible Doors, Pan Assembly For Easy Installation And Also Incoming And Outgoing Connections With Suitable Size Of Lugs / Thimblesincluding Taking Down Existing Unserviciable Mcb / Dbs Including Mcbs Complete All As Specified And Directed. 103 Supply, Installation, Testingofspn Distibution Board 4 Way, Double Door , Ip 43, As Per Is 8623Including 200 Amps Fully Insulated Copper Bus Bar, Insulated Neutral Bar, Earth Bar, Door Earthing, Reversible Doors, Pan Assembly For Easy Installation And Also Incoming And Outgoing Connections With Suitable Size Of Lugs / Thimblesincluding Taking Down Existing Unserviciable Mcb / Dbs Including Mcbs Complete All As Specified And Directed. 104 Supply And Fixing Of Mcb Single Pole, 240 Volts, 50Hz , Breaking Capacity 10Ka, B Curve 6 To 32 Amps, Including Connection With Suitable Size Copper Lugs Complete All As Specified And Directed. 105 Supply And Fixing Of Mcb Single Pole, 240 Volts, 50Hz , Breaking Capacity 10Ka, B Curve 40 To 63 Amps, Including Connection With Suitable Size Copper Lugs Complete All As Specified And Directed. 106 Supply And Fixing Of Mcb Single Pole And Neutral, 240 Volts, 50Hz , Breaking Capacity 10Ka, B Curve 40 To 63 Amps, Including Connection With Suitable Size Copper Lugs Complete All As Specified And Directed. 107 Material And Labour For Concealed Sub Main Wiring With Two Single Core Frlsh Pvcinsulatedunsheathed Copper Conductor Cable 2.5 Sqmm Drawnin And Including Rigid Non Metallic Pvc Medium Grade 25 Mm Dia Concealed Conduit With Accessories Onwall Or Ceiling Withone Additional Pvc Insulated , Strandedcopper Conductor Frlshof 2.5 Sqmm, Green Colourfor Earthcontinuity Conductor Including Taking Down Old Unserviceable Sub Main Wiringand Making Good The Disturbed Surface Complete All As Specified And Directed.Note : - 3 Run Of Cable And 1 Run Ofconduit Shall Be Measured As 1 Unit. ( Ii ) The Quoted Rates Shall Be Deemed To Be Inclusive For Cutting Chasesin Wall / Pillars / Columns Etc. Of Any Description For Concealing The Conduits To Required Depth & Making Good The Disturbed Surface In Cement Mortar 1:4 Including Finishing The Surface To Match With The Existing Surface. The Portion Of Sub Main Wiring At Ceiling Shall Be In Surface Conduit Of Suitable Size Fixed On Ceiling Surface With Using Necessary Aceessories / Fittings. 108 Material And Labour For Concealed Sub Main Wiring With Two Single Core Frlsh Pvcinsulatedunsheathed Copper Conductor Cable 4.00 Sqmm Drawnin And Including Rigid Non Metallic Pvc Medium Grade 25 Mm Dia Concealed Conduit With Accessories Onwall Or Ceiling Withone Additional Pvc Insulated , Strandedcopper Conductor Frlshof 4.00 Sqmm, Green Colourfor Earthcontinuity Conductor Including Taking Down Old Unserviceable Sub Main Wiringand Making Good The Disturbed Surface Complete All As Specified And Directed.Note : - 3 Run Of Cable And 1 Run Ofconduit Shall Be Measured As 1 Unit. ( Ii ) The Quoted Rates Shall Be Deemed To Be Inclusive For Cutting Chasesin Wall / Pillars / Columns Etc. Of Any Description For Concealing The Conduits To Required Depth & Making Good The Disturbed Surface In Cement Mortar 1:4 Including Finishing The Surface To Match With The Existing Surface. The Portion Of Sub Main Wiring At Ceiling Shall Be In Surface Conduit Of Suitable Size Fixed On Ceiling Surface With Using Necessary Aceessories / Fittings. 109 Material And Labour For Concealed Sub Main Wiring With Two Single Core Frlsh Pvcinsulatedunsheathed Copper Conductor Cable 6.00 Sqmm Drawnin And Including Rigid Non Metallic Pvc Medium Grade 25 Mm Dia Concealed Conduit With Accessories Onwall Or Ceiling Withone Additional Pvc Insulated , Strandedcopper Conductor Frlshof 6.00 Sqmm, Green Colourfor Earthcontinuity Conductor Including Taking Down Old Unserviceable Sub Main Wiringand Making Good The Disturbed Surface Complete All As Specified And Directed.Note : - 3 Run Of Cable And 1 Run Ofconduit Shall Be Measured As 1 Unit. ( Ii ) The Quoted Rates Shall Be Deemed To Be Inclusive For Cutting Chasesin Wall / Pillars / Columns Etc. Of Any Description For Concealing The Conduits To Required Depth & Making Good The Disturbed Surface In Cement Mortar 1:4 Including Finishing The Surface To Match With The Existing Surface. The Portion Of Sub Main Wiring At Ceiling Shall Be In Surface Conduit Of Suitable Size Fixed On Ceiling Surface With Using Necessary Aceessories / Fittings. 110 Taking Out Of Unserviceable Earthing And Material And Labour For Earthing And Material & Labour For Earthing With Galvanised Steel Earth Plate Electrode 60Cmx 60Cm X 6.0 Mm Thick Buried Directly In Ground Vertically At A Depth Not Less Than 2.25Metre Below Normal Ground Level With Top Edge Of Earth Plate At A Depth Not Less Than 1.5 Metre Below Normal Ground Level, Earth Plate Surrounded From All Sides By 15Cm Thick Packed Layer Ofcharcoal Dust And Common Salt Filling In Alternate Layers And Electrode Connections By Usinggalvanised Iron Wire 4Mmas Earthing Lead ( Upto Terminal Point ) By Means Ofbolts, Nuts, Check Nuts And Washers Made Of Galvanised Iron And Thimbles And Protected By Light Grade 15 Mm Diagi Pipe Connected To Main Switch Board Or Main Control Board And Gi Pipe Medium Grade 20Mm Bore For Watering And Including Funnel , Wire Mesh, 50 Mm Thick Precast Rcc 1:2:4 Type B1using 20 Mm Graded Stone Aggregate , Reinforced With 8 Mm Dia Dedormed / Tmt Bars 3 Nos Both Way 12 Mm Dia Round Bar Handle And Pcc Chamber Pit With Pcc ( 1:3:6 ) Type C-2 Using 40Mm Graded Stone Aggregate, Including Excavation And Earth Work In Any Type Ofsoil , Returning , Filling In Approved Soil And Disposal Of Surplus Soil To A Distance Not Exceeding 50M All As Specified And Shown In Electrical Plate No 3 Ofssr 2009 ( Part-I ) Complete All As Specified And As Directed. Note :- ( I ) Earth Lead Wire And Its Protection Pipe Upto And Including 7.50 Mtr Only From Top Of Earth Electrode Are Included Under This Item. ( Ii ) On Testing If The Earth Resistance Is Not Obtained Within Permissible Limit, Earthing Will Be Re-Done At No Extra Cost , Till The Desired Earth Resistance Is Obtained. ( Iii ) Any Joint In Earth Lead From Earth Electrode To Test Point Shall Not Be Allowed / Permitted. 111 Supply, Laying And Testing Of Cable Xlpe Insulated, Armoured Heavy Duty Electric Cable With Standred Aluminium Conductor, 1100 Volts Grade, Cross-Sectional Area Of Size 25 Sqmm 4 Core Including Dismantling Existing Any Type And Any Size Cable Complete All As Specified And Directed. 112 Supply, Laying And Testing Of Cable Xlpe Insulated, Armoured Heavy Duty Electric Cable With Standred Aluminium Conductor, 1100 Volts Grade, Cross-Sectional Area Of Size 10 Sqmm 2 Core Including Dismantling Existing Any Type And Any Size Cable Complete All As Specified And Directed. 113 Supply And Fixing In Repair Of Gi Protection Pipe Of 40Mmdia Light Grade For Cable Protection Including All Fittings Laid In Trenches Or Fixed On Pole, Complete All As Specified And As Directed. 114 Material And Labour For Supply And Filling Sand With Clean Dry Fine Sand Unwashed Including Gently Punning Around Cables In Trenches For Cable Protection Complete All As Specified And Directed. Note: - Punned Thickness Shall Be Measurement & Paid. 115 Material And Labour For Brick Protection Covers Over Cable Using Sub Class B Old Size Brick Laid Along Length Of Cable Complete All As Specified And Directed. 116 Supply And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Conductor, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Metre Apart Including 4Mm Suspension Wire, One Twin Core Cable Flat Or Circular Of Size 16Sqmm Including All Incoming And Outgoing Connection With Proper Size Of Thimble Including Disconnecting And Taking Down Existing Cables Etc. Complete All As Directed And Specified. 117 Supply And Fixing In Repair Of House Service Bracket ( Hook Type ) Complete With 3.0 M Long Gi Pipe 40Mm Dia Medium Grade Pipe, Two 90 Degree Bends. Ms Hook, Stay Or Guy Including Fixing Clamps Etc Complete All As Specified And Directed. 118 Note:- Amount Of Credit Ofrs. 74, 062.00 For Retrieved Materials Is Mentioned In Schedule Of Credit Page No 19 & 20 Of Tender Documents In Pdf Form Which Will Be Deducted Offline While Acceptance Of Tender.