}

Tender For Supply Of Veterinary Instrument/ Equipment/ Chemicals/ Re Agent/ Media, Cuttack-Odisha

Government Departments has published Tender For Supply Of Veterinary Instrument/ Equipment/ Chemicals/ Re Agent/ Media. Submission Date for this Tender is 15-12-2022. Coats and Jackets Tenders in Cuttack Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

34763504
Corrigendum : Tender For Supply Of Veterinary Instrument/ Equipment/ Chemicals/ Re Agent/ Media
Open Tender
Indian
Odisha
Cuttack
15-12-2022

Tender Details

Tender For Supply Of Veterinary Instrument / Equipment / Chemicals / Re Agent / Media Supply Of Veterinary Instruments / Equipments / Chemicals / Reagents / Media , Hematology Auto-Analyzer , 5 Part Veterinary Hematology Analyzer For Veterinary Use Only And Not For Human, With Feature Of Direct Mode To Select The Canine, Feline, Equine, Bovine, Ferret, Gerbil, Rabbit, Pig, Mini Pig And Guinea Pig, Goat, Sheep, Llama, Alpaca, Camel, Dolphin, Based On Laser Flow Cytometry, Optical Fluorescence And Laminar Flow Impedance Technology To Measure All 26 Parameters: Red Blood Cell – Rbc, Hematocrit - Hct%, Hemoglobin - Hgb, Mean Corpuscular Hemoglobin Concentration - Mchc, Mean Corpuscular Volume – Mcv, Mean Corpuscular Hemoglobin – Mch, Red Cell Distribution Width – Rdw, Reticulocyte Count % , White Blood Cell – Wbc, Neutrophils - % And Neutrophils Absolute Numbers, Lymphocytes - % And Lymphocytes Absolute Numbers, Monocytes - % And Monocytes Absolute Numbers, Eosinophils - % And Eosinophils Absolute Numbers, Basophils - % And Basophils Absolute Numbers, Platelets – Plt, Mean Platelet Volume – Mpv, Platelet Distribution Width – Pdw, Plateletcrit Value – Pct, Requiring Less Than 30 ?L Of Anticoaguled Whole Blood, With Other Important Parameters Reticulocyte Hemoglobin, Band Neutrophil And Reticulocyte Count Also, Also To Report For Other Parameters Like Nucleated Rbc, Band Neutrophil Etc If Presence Suspected In Sample, Requiring Two Reagent Kits One External And One On Board, With Results In Two Minutes, Storeall Consumables At Normal Room Temperature And No Refrigeration Required, Standby Mode, External Printer Interface Facility To Get The Printouts With All Parameters Including Dot Plot, Integrate With The Laboratory Information Management System For Analyzer Operation As Well As Patient Information With Patient Records, Us Fda / Ce / Iso Approved , Trinocular Microscope , Trinocular Microscope: Head: Trinocular 30 Degree Inclined W / Photo Tube & C-Mount Eyepieces: Cfi E 10X ( 20Mm ) Objectives: Cfi E Plan Achromat 4X, 10X, 40X, 100X Oil Stage: Mechanical Stage With Slide Holder Condenser: E2 Abbe Condenser N.A. 1.25, Aperture Diaphragm With Position Guide Markings For Respective Cfi E Plan Objectives Focus: Coaxial Coarse / Fine Focus Controls Illumination: Led Illumination Misc: Dust Cover, Power Cord, Manual Warranty: 5 Year Mechanical And Electrical Camera Specifications: Screen ( Optional ) Mountable 11.6 Retina Display Screen ( Hardware Included ) Resolution ( Live ) : 1920X1080 - Captured 5 M.P. Sensor: 1 / 2.5 ( 0.5X C-Mount Recommended ) ; Aptina Mt9p031 Frame Rate: Hdmi ( 30Fps ) ; Usb 2.0 ( 15Fps ) Image Capture: High Speed Sd Card ( 4Gb ) Video Capture: Hdmi: 1080P, 30Fps To Sd Card Usb 2.0: 1080P, 15Fps To Pc Or Mac Exposure Time: 0.001 Sec - 10.0 Sec White Balance: Auto Settings: Gain, Gamma, Saturation, Contraction Built-In Software: Cloud 1.0 Pc Imaging Software: Captavision Imaging Software ( For Pc Only; Mac Os Not Supported ) Advanced Camera Controls: Live / Still Image Measurement And Annotation, Flat Field Correction; Extended Depth Of Focus ( Focus Stacking ) ; Image Stitching; Hdr ( High Dynamic Range ) Function Image Types: Jpeg, Bmp, Tiff And Raw Output Modes: Mode 1: Usb 2.0 / Mode 2: Hdmi System Compatibility: Windows Xp, Vista 7 And 8, And 10 ( 32 Or 64-Bit ) Mac Os X ( For Image Transfer To Mac Os X Only ) System Requirements: Intel Processor ( Core 2 Duo Or Higher ) ; 2Gb Memory Or More; Usb 2.0 Hi-Speed Port Power Supply: Dc12v / 1A , Reinforce Protection Glass 11. Stainless Steel Darkroom 12. 10 Positions Filter Wheel To Be Supplied With The 590Nm Interferential Filter With The System For Ethidium Bromide Application 13. Auto-Exposure, Auto Focus And Automatic Illumination Control 14. The Field Of View Should Be Approximately 21X26 Cm At The Uv Transilluminator ( Slide-Out, Uv 312Nm Excitable ) Level. The Transilluminator Should Be Slide Outdesign. 15. The Uv Transilluminator Is To Be Stained Free Compatible, As Well As For The Most Common Dna / Rna Dyes 16. The System Should Be Upgradable In Future With Up To 6-8 Excitation Channels In The Uv And Visible Area For A Large Array Of Applications Such As Dna Or Rna Gels, 1D Protein Fluorescent Gels, Stain Free Gels 17. A Complete Library That Contains The Excitation And The Emission Spectra Of The Main Fluorophores Used In Modern Molecular Biology Laboratory Should Be A Built-In Feature Of The Software. It Also Should Suggest The Best Possible System Configuration In Terms Of Light Source Excitation, Emission Filter And Sensitivity Level Of Applications To Ensure Reproducibility And Ease Of Use. 18. White Light Conversion Plate Should Be Supplied 19. Facility Must Be Available To Upgrade With Blue Conversion Screen For The Excitation Of The Syber Green And Of The Sybr Safe 20. Suitable Branded Desktop Computer Must Be Quoted As Optional 21. Service Engineer Should Be Available At Bhubaneswar 22. Warranty- 1 Year , Rnase Jap , Steri Sweep Molecular Grade , Petridsih Disposable, 100Mm , Bq Rapid Test Kit , Goat Pox Virus Antigen Rapid Test Kit , Hs Rapid Test Kit , Ppr Virus Antigen Detection Rapid Test Kit , Rd Virus Antigen Detection Rapid Kit , Rotheras Mixture Lr , Super Script™ Iii Platinum™ One-Step Qrt-Pcr Kit Catalog Number:11732020 Molecular Grade , Cryo-Container 3 Litres , ( Capacity-3 To 4 Lts Of Ln2 With Static Evaporation Loss Rate Of 0.135 Litres Per Day At Stp, 6 Canisters With Od 38 Mm, Height 120Mm. The Level Of Ln2 From Bottom Should Be About 20Cm. The Neck Diameter Should Be 50Mm. The Container Is Meant For Private Ai Practitioners & Should Be Sturdy ) , Cryo-Container 35 Litres , ( High Strength Aluminium Alloy Liquid Nitrogen Container, Neck Diameter About50mm, Loss Mass- 0.29 Litre Per Day, Static Holding Time-123 Days ) , Frozen Semen Straw Lifter-10 , Stainless Steel, L Shaped, Designed To Lift Semen Straws With Vertical Serrationsmade At The Tips ( 10’’ ) , Kit Bag, Nylon Fabricated Materials, Water Proof With Good Quality Chain Having Two Main Inside Partitions & One Outsidebox Pocket, With Hanging Handle & Back Carrying Belt, 12 Height, 21 Length, 7 Width, Able To Carry 10 Kg Weight , Burdizzo Castrator For Bull Calf, Made Up Of Stain Less Steel ( 19 Length ) For Bull Calf. Burdizoo Pattern Castrators For Large Animals Consist Of Two Jaws ( Upper Jaw And Lower Cord Stop Jaw ) With Two Levers Coupled With Nuts. Material Carbon Steel Length ( Total ) 19” Width Of Upper Jaws 75 Mm + / - 2 Mm Lower Jaw ( Cord Stop Jaw ) Cord Stop Of 5-8 Mm Ht. On Both Sides ( The Gap On Either Side Between The Upper Jaw And Lower Jaw ( Having Cord Stop ) Should Range Between 1 To 1.5Mm ) Other Requirements:- 1. Tenderer For Imported Castrators Should Submit Proper Letter Of Authority From Their Principals. 2. The Offered Product Should Be In Indian Market For At Least 2 Years. 3. List Of Actual Users To Whom Same Brand Is Supplied Should Be Submitted With Copy Of Ratecontract / Supply Order Etc. 4. The Castrators Should Be Guaranteed For Satisfactory Performance For A Period Of Minimum One Year From Date Of Supply, During Which The Bidder Shall Be Liable To Be Replaced The Castrators At His / Herown Cost, If Any Complaints Are Received From End User. 5. Castrator Should Not Leave Any Gap Between Upper And Lower Jaw During Castration. 6. The Castrator Should Be Supplied Along With Spanner. With The Help Of Spanner All The Nuts Ofcastrators Shall Be Alternatively Loosened And Tightened Five Times And Neither Nuts Nor Jaws Ofspanner Shall Show Any Sign Of Damage Or De Shape. 7 . Name Of Manufacturing Company Should Be Permanently Embossed / Etched On The Body Of Castrator. , Cryo-Container 50 Litres , ( Liquid Nitrogen Container 50L, Neck Diameter About50mm, External Diameter 500Mm, Height 790Mm, Loss Mass- 0.37 Litre Per Day, Static Holding Time-134 Days ) , Digital / Electronic Semen Thaw Unit 475 Ml Capacity ( For Bovine ) , Made Up Of Stain Less Steel, Thermoflax Model With One Side Handle, With Digital Display Temperature, Having A Plastic Canister Inside To Keep / Lift The Semen Straw, With A Power Cable To Heat, Dimension ( Lxwxh ) ( 4.7 X 4.2X 9.5 ) , Weight ( Empty ) -610G, Power-74W, Rated Frequency- 50Hz, Rated Voltage-220V Ac, Capacity-475 Ml , Frenchmini Empty Straw, Pvc Straw Of Different Colours.Pack Of 2000 Straws ( 0.25Ml ) . Total Length 133Mm + / - 0.25 0.5Mm, External Diameter 1.99Mm , Internal Diameter 1.63Mm, 0.25Ml -Low Absorption Alpha Type With Flouroscent Plug Technology For Precise Filling And Safety , Cryo Gloves , Can Withstand To Retrieve The Frozen Semen Straw From Liquid Nitrogencryo Container , Portable Veterinary Ultrasound Machine , 1. It Should Be Portable Veterinary Touch Screen Color Doppler Ultrasound Unit Having Minimum12” Lcd Led Backlit Screen Size And Should Not Be Weighing More Than 4 Kg Includingbattery. 2. It Should Be Meant Forcanine, Feline, Equine, Bovine, Lama, Pig, Sheep And Others And Should Have True Veterinary Software 3. It Should Have Intuitive Interface, Touch Pad And Touch Key Board 4. It Should Have Touch System To Select Imaging Modes Like: B, B+B, Power B, B+M, M, Cfm Andpw . 5. The Machine Should Offer Dual Cfm- B / Cfm, Adjustable Region Of Interest ( Roi ) , 6. Itshould Offer Image Orientation From Left – Right And Up & Down 7. It Should Have Battery Backup For Minimum 3 Hours And Charging Time Should Not Be More Than 3 Hours 8. It Should Have Minimum 2 Usb Connectors, Wi-Fi Compatibility To Send Images To Ipad And Other Smart Devices , Basic Dicom, Stereo Sound And Bluetooth Compatibility . 9. It Should Have Digital Touch Control For All The Operational Features Like- Adjustment Of Tgc, Gain, Brightness & Contrast, Image Orientation, Focus, Freq, Depth And Dynamic Range. 10. It Should Display Mi & Ti Indexing On The Screen By Default And Should Be In The Permissible Limit As Per Fda And Overall Safe. 11. The Machine Should Be Able To Generate Report Of The Animal Combined With Images To Further Send Through Digitally In Multiple Forms 12. The Ultrasound Machine Should Be Offering Absolutely Very High Image Quality Hence Should Be Using Digital Dual Beam Former And Computing And Should Be Using Minimum 128 Reception Channels And Around 60 Emission Channels Or More. 13. It Should Have 500Gb Hard Disc Capacity 14. The Machine Should Offer Both Portrait And Landscape Imaging View 15. The Machine Should Be Having Hdmi And Wi-Fi Compatibility 16. It Should Have 256 Grey Scale 17. The Machine Must Be Able To Take The Voice Command Of The User To Adjust Depth, Probe Frequency, Focus, Gain And Freeze In B Mode 18. It Should Be Provided With One Micro Convex Probe Having 5-7.5Mhz Frequency Suitable For Small Animal Abdomen 19. It Should Be Offered With Endo Rectal Probe Having Frequency Of 5-10Mhz And 600 Mm Footprint Of The Scanning Face Of The Probe For Large Animal Reproduction And Fetal Sexing On Animal. The Endo Rectal Probe Should Be Atleast 2.5 Meter Long. 20. It Should Have Digitized Tgc Upto 8 Adjustable Zones And Should Be Adjustable With Touch Only 21. The Ultrasound Machine Should Be Fully Compatible For Opu Operation On Animal And Offer Ergonomics Applications To Carry Out Ovum Pickup Successfully With Compatible Devices For Future Procurement. 22. The Machine Should Be Supplied In A Hard Plastic Carry Case Having Proper Housing For Machine And Accessories. 23. The Machine Should Have An Ergo Mount Adaptor For Mounting The Machine On Certain Device / Stand. 24. It Should Have Patient, Hospital And Reporting Format. 25. The Machine Should Be Ce Marked. 26. It Will Be Inevitable On The Part Of The Supplying Company To Arrange And Provide Extensive Clinical Training For Two Days On Animals To Teach About Topographic Anatomy Using Ultrasound And Different Applications Of The Machine For Its Ergonomic Purpose By A Qualified Veterinary Specialist At A Common Venue. 27. The Principal Maufacturing Company Of Offered Product Should Have Their Direct Office And Service Centre In India With Good Strength Of Engineers. 28. The System Offered Should Be Warranted For At Least One Year. , Cryo Can -1.5 Ltr, Capacity 1.5Lit, Material : Aluminium , Static Evaporation Rate : 0.05 Lit / Day To 0.1 Lit / Day , Cryo-Container 55 Litres , Capacity 55Lit, Material : Aluminium , Static Evaporation Rate : 0.43 Lit / Day To 0.45 Lit / Day , Jumbo-12, Capacity 47Lit, Canister : 11, Material : Aluminium , Static Evaporation Rate : 0.35 Lit / Day To 0.4 Lit / Day , Liquid Nitrogen Transfer Hose Pipe ( Non Insulated ) -5 Mt, 1 / 2 Inch Nb 5 Mt Long Flexible Non- Insulated Vacuum Hose Along With Gaskate. , Wide Mouth Container ( Storage Vat Of Frozen Semen Straws ) -390 Liters, •Wide Mouth Container Made Of Non-Magnetic Stainless Steel Of Approximate 390 Ltrs Capacity. •Should Have Capacity To Store More Than 3.9 Lacs Straws Of 0.25 Ml ( With Canisters ) •Static Holding Time: Minimum 30 Days •Internal Diameter: Approx. 770 Mm •Empty Weight: Not More Than 200 Kg •Total Weight ( Including Samples ) : Not More Than 520 Kg •Total Height: Max. 1320 Mm •Daily Evaporation Rate Should Be Less Than 10 Ltr. / Day . •Should Be With Temp. Indicator, Low Temperature Alarm, Level Indicator, Low Level Alarm Indicator. •Should Have Option Of Auto Filling & Interface For Remote Monitoring •Heavy-Duty Casters To Provide Mobility Within The Lab. •The Equipment Must Be Quoted With One-Year Warranty Including Installation. The Concern Should Have Experience Of Installing Successfully At Least ( 03 ) Five Such Systems In Cmu Graded Semen Labs In India, For Which Necessary Documents Must Be Attached. The Satisfactory Working Report From The User Also To Be Attached. , 5 Ply Corrugated Card Board Box, Size-355Mm X 305 Mm X30mm , Ss 316 Storage Tank, Capacity-200Liters, With Accessories Ss 316 Storage Tank, Capacity-200Liters, With Accessories •M.O.C Of All Contact Parts : Ss 316 •M.O.C Of All Non-Contact Parts : Ss 304 Type Of Tank : Torispherical Dish End Vertical Tank •Dia: 700Ø / Shell Ht.: 550 Mm •Shell / Dish Thickness: 4 Mm Steam Heating Jacketed Tank Dia.800Mm X 4Mm Thk. •Shell Thickness: 4 Mm - Ss 304 •Tank With Heat Insulation Jacket With Rockwool Insulation - Dia. 900 Mm •Shell Thickness : 2 Mm - Ss 304 •Tank Internal Surface Mirror Polished. • Volume Sensor-1 No • Ph Sensor-1 No Accessories •Temperature Sensor - 1 No. •Steam Inlet Valve3 / 4 - 1 No. •Steam Trap Assembly3 / 4 - 1 No. •Steam Safety Valve With Pr. Gauge 1 No. •Control Panel- 1 No. •Ss 316 Diaphragm Valve, Size:1 -2 Nos •Vent Filter With Electrical Heating, 10 Long 0.2 Micron P7 Pp Cartridge-1 No. •Sight Glass Assembly3- 2 Nos •1 Tc Compound Pr. Gauge With 4 Dial, -1 To 10 Bar Pressure- 1 No. , Non Invasive Multiplexed Biomass Sensor System, Automated, Continuous, Real Time, Multi Vessel Biomass / Od Monitoring With Working Volume Done To 10 Ml, Biomass Sensitive Range Less Than 0.01 To Greater Than 600 Od Units, 12 Mm Diameter , Peristaltic Pump-201Vnotor-Stepper With Motor Torque-10Kg, Rpm- 1 To 200, Tube Size- 1 To 8 Mm, Flow Rate- 0.8 To 1800Ml / Min, Discharge Pressure - 2Bar, Maximum Discharge Height- 10 Litres, Dimension- ( L-325 X W-170 X H-250 ) Mm , Peristaltic Pump-401Vnotor-Stepper With Motor Torque-1 / 6 Hp, Rpm- 20 To 240, Tube Size- 8 To 19 Mm, Flow Rate- 250 To 20000Ml / Min, Discharge Pressure - 3Bar, Maximum Discharge Height- 30 Litres, Dimension- ( L-500 X W-250 X H-400 ) Mm , Absorbent Cotton Ip 500Gm Pkt ( Each ) , 500 Gm, Absorbency Not More Than 10Sec. , Cover Slip -Glass / Disposable, , Circular / Rectangular-100 Nos / Pkt ( 100 Nos ) , Cover Slip -Glass, Optically Clear, Distortion Free Surfac, Circular & Rectangular-100 Nos / Pkt , Cryovial 1.8Ml / 4.5Ml, Pp, Pkt Of 100, Material-Plastic , Disposable Needle-Strile 18 Gauze Needle Indivually Covered With A Cap In Blister Pack ( Each ) , D76 , Disposable Needle-Strile 20 Gauze Needle Indivually Covered With A Cap In Blister Pack ( Each ) , D76 , Disposable Needle-Strile 22 Gauze Needle Indivually Covered With A Cap In Blister Pack ( Each ) , D76 , Disposable Syringe With Needle-Sterile, Graduated, 10Ml With 18 G Needle Packed Individually ( Each ) , Disposable Syringe With Needle-Sterile, Graduated, 20Ml With 18 G Needle Packed Individually ( Each ) , Disposable Syringe With Needle-Sterile, Graduated, 2Ml With 20 G Needle Packed Individually ( Each ) , Disposable Syringe With Needle-Sterile, Graduated, 5Ml With 18 G Needle Packed Individually ( Each ) , Gauze Cloth , 100% Cotton, 90Cm X 16 Mtr ( Each ) , Gauze Cloth 90Cm X 16 Mtr Bandage 10 Cm X 3 Mtr ; 15 Cm X 3 Mtr , Haematocrit Tubes Acc. To Wintrobe, Soda Lime Glass, Straight Rim, Round Bottom, Double Numbered Scale In Red / White Colour, 105 Mm Subdivided In 1 Mm, Outside Diameter Approx. 6.5 Mm, Inside Diameter Approx. 2.9 Mm, In Cartons Of 20 Pcs. , Non -Absorbent Cotton Ip.500Gm Pkt ( Each ) , Pop Bandage 6 , Roller Bandage 10Cm X 3M, Gauze / Cotton, Pack Of 10 ( Pkt Of 10 ) , Roller Bandage 15Cm X 3M, Gauze / Cotton, Pack Of 10 ( Pkt Of 10 ) , Ph Paper , With Universal Indicator 1 To 14 , Glass Slides, Microscopic -Optically Clear, Distortion Free Surface , Bunsen Burner, Gear Type: Natural Gas, Material: Stainless Steel, Btu Output: 1200 Per Hour, Inlet Tube Od: 0.4375 Inches, Height:6 Inches , Digital Balance, Base On Electromagnetic Force Compensation Technology To Match The Highest International Standards . High Integrated Weighing Scale.Internal Adjustments Caliberation: Lb- C3 Type Caliberation. Motorized Internal Built In Weight Caliberation.Lb-C Series. Psas Fully Automatic Time And Temperature Controlled Internal Adjustments.Lb-C Series. Automatic External Caliberationlb-C / Lb Series Balance Protection.Smart Keystop Calliberation. Menu Lock ( Settings Password Protection ) . Overload Protection.Ip54protection Class. Overview: Display : Lcd High Contrast Display With Led Back Light. Large Glass Draft Shield With 3 Sliding Doors For Easy Acess To Items Being Weighted Key Pad Cover With Plastic Protection.. Tare Key Left / Right Sidefor User Friendly.Bubble Level Indication With Adjustableleg Uniform Surface Level.Balance Is Equipped With Rs232 Ouput Interface Connect Balance Pc Or Statistical Printer.Windows Direct Communication.. Usb Interface Optional. High Grade Materialconstruction Protects Against Chemicals And Rough Handling.Application: Piece Counting, Check Weighing , Percentage Weighing, Tantalization., Animal Weighing, Density Determination, Statistics, Custom Weighing Unit Formulation, Below Weigh Hook . Internal Caliberation: Model: Lb224c- Max- 220Gm, D-0.1 Mg, Pan Size-90Mm, Analaytical Balance:220Gm; Lb224c. External Calliberation:Lb224-220Gm D- 0.1 Mg, Pan Size 90Mm , Ai Tray, Stainless Stell 55-60Cm X25-30 Cm , Calf Puller Consist Of Precision Threaded Shaft Of 76 Long In Two Part With Breech Spanner For Pelvic Bones .Frictionjack Fittingwith Leg And Tractionbelt For Smooth Calf Delivery , Spay Snook Hook, Stainless Steel, Blunt 8 Inch Convex , Goblet Holding Forcep ( 18 ) , Stainless Steel, Lock Types Goblet Holding Forcep , Bipolar Thermocuttery Unit, Microcontroller Based Isolated Electrosurgical Generator Having Both Monopolar And Bipolar Outputs Designed For All Surgical Procedures, All Cut Modes Should Be Able To Adjust Output Power Depending On Tissue Density By Less Than 15% Or 5W, Whichever Is Greater. Should Have Three Coag Modes With Maximum Power Of 120W, It Should Have Three Bipolar Modes With Maximum Power Of 70W, The Unit Should Have Two Hand Switching And Two Footswitch Monopolar Outputs And One Hand Switching And Foot Switching Bipolar Output, The Unit Should Have Individual Digital Display Of Power For Bipolar, Monopolar Cut And Monopolar Coag. The Unit Should Not Have Rf Leakage Current More Than 150Ma. The Unit Should Not Have Rf Leakage Current More Than 150Ma. Two Years Of Comprehensive Warranty Including Bulbs Should Be Provided Along With Technical Support. It Should Follow International Safety Standard And Requirement With Ce Certification Or Usfda Approval. Operating And Service Manual Should Be Supplied. , Air Drill, High Speed Air Handpiece: 360, 000 Rpm Variable High Speed Handpiece, Low Speed Air Handpiece: Up To 20, 000 Rpm For Slow Speed Control., Complete Prophy Starter Kit, 3-Way Air Water Syringe: Allows The Operator The Ability To Rinse The Operative Site With A Stream Of Water Or Mist Or Dry / Blow Debris With A Stream Of Air. Foot Pedal Control: The Foot Switch Is A Durable Chrome-Plated Pedal. By Pressing Harder On The Foot Switch It Will Deliver More Power To The High Speed Handpiece Controlling The Speed Easily. , Burdizzo Castrator Small, Burdizoo Pattern Castrators For Small Animals Consist Of Two Jaws ( Upper Jaw And Lower Cord Stop Jaw ) With Two Levers Coupled With Nuts. Material For Small Animals:Material Carbon Steel Length ( Total ) 220-230 Mm Width Of Upper Jaws 42 Mm + / -2Mm Lower Jaw ( Cord Stop Jaw ) Cord Stop Of 5-8 Mm Ht. On Both Sides ( The Gap On Either Side Between The Upper Jaw And Lower Jaw ( Having Cord Stop ) Should Range Between 1To 1.5Mm ) Other Requirements:- 1. Tenderer For Imported Castrators Should Submit Proper Letter Of Authority From Their Principals. 2. The Offered Product Should Be In Indian Market For At Least 2 Years. 3. List Of Actual Users To Whom Same Brand Is Supplied Should Be Submitted With Copy Of Ratecontract / Supply Order Etc. 4. The Castrators Should Be Guaranteed For Satisfactory Performance For A Period Of Minimum One Yearfrom Date Of Supply, During Which They Shall Be Liable To Replace The Castrators At Their Own Cost, If Any Complaints Received From End User. 5. Castrator Should Not Leave Any Gap Between Upper And Lower Jaw During Castration. 6. The Castrator Should Be Supplied Along With Spanner. With The Help Of Spanner All The Nuts Ofcastrators Shall Be Alternatively Loosened And Tightened Five Times And Neither Nuts Nor Jaws Ofspanner Shall Show Any Sign Of Damage Or De Shape. 7. Name Of Manufacturing Company Should Be Permanently Embossed / Etched On The Body Of Castrator. , Drenching Gun, Usage / Application - Drenching For The Entire Herd, Automation Grade / Semi-Automatic, Finishing- Color Coated, Capacity- 23 Ml , Endo Tracheal Tube No 06, Size-6 Inch, Application- Hospital, Steribility- Sterile, Material- Pvc, Color- White Transparent , Endo Tracheal Tube No 08, Size-8 Inch, Application- Hospital, Steribility- Sterile, Material- Pvc, Color- White Transparent , Et Tube ( Size 2-12 ) , Size- 2Mm To 12 Mm, Cuff Type- Cuffed , Hartman Ear Forcep, Composition: Stainless, Customer Segment: Hospitals, Surgery Centers & Tissue Banks, Finish: Satin, Grade: Or, Item Type: Forceps, Length - Working ( Mm ) : 64, Length 1 - Tip / Jaw ( Mm ) : 6, Physician / Developer: Hartmann, Shape: Straight, Therapeutic Specialty: Otology, Usage: Reusable, Width 1 - Tip / Jaw ( Mm ) : 1.5 , Laryngoscope, Battery Handel, Throat Cannual, With 2 Attachment For Anesthesia. , Pm Kit, 1 ) Amputation Saw, Stainless Steel 2 ) Wire Saw With Handle, Stainless Steel ( Gigil Wire Saw ) 3 ) One Spare Wire For Wire Saw4 ) Post-Mortem Knife 5 ) Full Hand Gloves, Size-6 & 7 6 ) Post-Mortem Gloves, Latex, Size-6 & 77 ) Bone Hammer8 ) Bone Chisel9 ) Post - Mortem Scissor, Stainless Steel10 ) Scalpel, Stainless Steel11 ) Allis Tissue Forceps, Stainless Steel 1512 ) Sharpening Stone13 ) Probe, Stainless Steel14 ) Scissor, Dressing, Stainless Steel15 ) Bowel Scissors, Stainless Steel16 ) Retractor Four Prong Sharp 17 ) Retractor Four Prong Blunt 18 ) Dissecting Forceps, Toothed, Stainless Steel 19 ) Bone Holding Forceps, Stainless Steel 20 ) Abscess Knife, Stainless Steel22 ) Bone File23 ) Measuring Tape 24 ) Vice With Two Adjustable Jaws Made Of Iron For Cutting Heads Of Animal. , Small Animal Dental Instrument Set, D107 , Suture Cutting Scissor, Size- 6 Inch, Material- 304 Grade Stainless Steel, Material Grade- Aisi Grade, Automation Grade- Manual, Handle Type- Finger Ring , Opthalmoscope, Technical Specifications Of Opthalmoscope: 1. Dimensions: 5.12” L X 1.40” W X 3.75” H Without Eyecup ( With Eyecup: 1.45” L ) 2. Weight: 48 Lbs Without Eyecup; 50 Lbs With Eyecup 3. Focusing Range: -20 To +20 Diopters Other Features Of Opthalmoscope: 1. First Easy Entry Into Undilated Pupils 2. 5X Larger View Of The Fundus Vs. Standard Opthalmoscopes In An Undilated Eye 3. 25 Degree Field Of View Vs. Standard 5 Degree Field Of View 4. Greater Working Distance Improves Comfort For Both Practitioners And Patient 5. Patented Glare Extinguishment System Prevents Interference From Unwanted Glare And Reflections 6. Halogen Hpx Lamp Provides Bright 7. Compatible With All Existing Welch Allyn 3.5 V Power Sources 8. Digitally Capture, Store And Share Fundus Images By Combining With Eye Examiner For I Phone 4 / 4S, Eye Examiner For I Phone 6 / 6S And Eye Examiner For I Phone 6 Plus / 6S Plus Adapters 9. The Veterinary Pan Opthalmoscope Has A 3 Spot Sizes: Micro, Small And Large With Add On Magnifying Lens 10. One Year Warranty , Automatic Urine Analyzer , Veterinary Urine Analyzer For Veterinary Use Only And Not For Human For Species Canine, Feline And Equine, Based On Urine Strip Reflectance Technology To Measure All Parameters: Ph, Leu ( Leukocytes ) , Pro ( Protein ) , Glu ( Glucose ) , Ket ( Ketones ) , Ubg ( Urobilinogen ) , Bil ( Biliruben ) Single Test Urine Strip To Measure All Above Parameters, Very Light Weight And Not More Than 1 Kg With Calibration Strip For Calibration Of The Analyzer On Fix Frequency, Able To Storeall Consumables At Normal Room Temperature And No Refrigeration Required, Maintenance Free And Ready To Use, Can Be Integrate With The Laboratory Information Management System ( Optional ) With In Built Thermal Printer To Printout All Parameters, Lcd Display For Operating The Analyzer Ce / Iso Approved , Automatic Blood Analyser, 5 Part Veterinary Hematology Analyzer For Veterinary Use Only And Not For Human, With Feature Of Direct Mode To Select The Canine, Feline, Equine, Bovine, Ferret, Gerbil, Rabbit, Pig, Mini Pig And Guinea Pig, Goat, Sheep, Llama, Alpaca, Camel, Dolphin, Based On Laser Flow Cytometry, Optical Fluorescence And Laminar Flow Impedance Technology To Measure All 26 Parameters: Red Blood Cell – Rbc, Hematocrit - Hct%, Hemoglobin - Hgb, Mean Corpuscular Hemoglobin Concentration - Mchc, Mean Corpuscular Volume – Mcv, Mean Corpuscular Hemoglobin – Mch, Red Cell Distribution Width – Rdw, Reticulocyte Count % , White Blood Cell – Wbc, Neutrophils - % And Neutrophils Absolute Numbers, Lymphocytes - % And Lymphocytes Absolute Numbers, Monocytes - % And Monocytes Absolute Numbers, Eosinophils - % And Eosinophils Absolute Numbers, Basophils - % And Basophils Absolute Numbers, Platelets – Plt, Mean Platelet Volume – Mpv, Platelet Distribution Width – Pdw, Plateletcrit Value – Pct, Requiring Less Than 30 ?L Of Anticoaguled Whole Blood, With Other Important Parameters Reticulocyte Hemoglobin, Band Neutrophil And Reticulocyte Count Also, Also To Report For Other Parameters Like Nucleated Rbc, Band Neutrophil Etc If Presence Suspected In Sample, Requiring Two Reagent Kits One External And One On Board, With Results In Two Minutes, Storeall Consumables At Normal Room Temperature And No Refrigeration Required, Standby Mode, External Printer Interface Facility To Get The Printouts With All Parameters Including Dot Plot, Integrate With The Laboratory Information Management System For Analyzer Operation As Well As Patient Information With Patient Records, Us Fda / Ce / Iso Approved , Automatic Urine Analyzer , Veterinary Urine Analyzer For Veterinary Use Only And Not For Human For Species Canine, Feline And Equine, Based On Urine Strip Reflectance Technology To Measure All Parameters: Ph, Leu ( Leukocytes ) , Pro ( Protein ) , Glu ( Glucose ) , Ket ( Ketones ) , Ubg ( Urobilinogen ) , Bil ( Biliruben ) Single Test Urine Strip To Measure All Above Parameters, Very Light Weight And Not More Than 1 Kg With Calibration Strip For Calibration Of The Analyzer On Fix Frequency, Able To Storeall Consumables At Normal Room Temperature And No Refrigeration Required, Maintenance Free And Ready To Use, Can Be Integrate With The Laboratory Information Management System ( Optional ) With In Built Thermal Printer To Printout All Parameters, Lcd Display For Operating The Analyzer Ce / Iso Approved , Otoscope / Auroscope, Otoscope Set , Inverter, Capacity: 900 Va / 12V; Maximum Bulb Load - 756 Watt, Protection: Mcb For Protection From Input Mains & Safety Alarm To Warn In Case Of Short Circuit, Display: Lcd Display For The Status Of Power Back-Up / Battery Charging Time In Hours And Minutes, Inverter Battery Capacity: 80 Ah - 150Ah, Battery Type: Tall Tubular Inverter Battery , Nominal Voltage: 12V; Rated Capacity At 27Oc: 200 Ah , Bench Platform Stainless Steel Weighing Balance ( Capacity 200Kg ) , Calibration- Internal, Weighing Capaciy Upto 200Kg, Material-Ms , Restraining Chain For Dog, Dog Restraint Heavy-Duty Tie-Out Chain Featuring Two ( 2 ) Snap Hooks, Lengths: 3 – 4 Meters, 3-5 Mm, Stainless Stell , Electric Water Heater, Capacity- 25-50 Litres, Max Rated Pressure- 5-10 Bar, Power ( Kw ) -2-4 , Stretcher Trolly For Small Animals, Stainless Steel Stretcher Trolley For Small Animal , Removable Stretcher, Attachment Hooks, Stainless Steel Tray, Possibility Of Integrating A Coloured Carpet With Frame, 4 Retractable Handles As Well As 4 Castors, 2 Of Which Have Brakes. , Muzzel For Dog Restrain, For Dog , Needle Destroyer, Input Electrical Supply- 1Ph, 230 Vac ( + / - 10% ) , 50 Hz ( + / -3% ) , Enclosure- Abs Plastic Injection Molded, Power Consumption- 100 Watts ( Minimum ) In Continuous Rating, Destruction Capacity- Needles Of Size Dia 0.4 Mm To 1.6 Mm, Syringe Cutter- Hardened Stainless Steel Cutter, Collection Tray Capacity- Maximum 200 Nos Of Cut Syringe Hubs & Swarf Of Destroyed Needles. Overall Dimensions- 230 ( L ) X 150 ( W ) X 95 ( H ) Mm. Weight In Kgs: 2.0 Approx. , Pet Hair Trimmer, Low Noise Cordless With 4 Comb Guides Scissors Pet Hair Trimmer , Pet Nail Cutter, Stainless Steel Sharpness Blades, Secure Grip Rubber Coated Non-Slip Handles, Safety Lock Mechanism, Safety Guard , Staining Rack, Designed For The Staining Of Upto 25 Microscope Slides , Travis For Pet ( Squeeze Cage ) , Heavy Duty Metal Cage To Restrain Pet Dog / Cat ( Length-30, Breadth-16, Height-20 ) , Ot Table, Side End Control Ot Table Is Mobile, Hydraulic Designed For Small Animal Surgery. Adjustable Height Functions. The Surface Of The Table-Top Should Beplain And Is Smooth And Easy To Clean And Disinfect. The Base And Column Of The Table Should Be Of High Quality Medical Stainless Steel. Non-Reflecting Surface, Antibacterial & Easy To Clean. Height Adjustment By Stepping Foot Pedal Downward. Lateral Tilts, Trendelenburg, And Are Realized By Handle Manually. Equipped With Drain System. , Ambu Bag, 265Mm With 85Mm Diameter. Volume: 1500Ml Weight: 190G Components: - Connector, Complete, Towards Patient Valve ( 24.3 ) . - Outer Cover ( 24.2 ) - Inner Bag ( 24.1 ) - Inlet Valve For Combined Air And Oxygen: Complete With Silicone Membrane And Tube Connector For The Oxygen Reservoir ( 24.7 To 24.10 ) , Infrared Lamp, Power- 300W-4000W, Voltage- 110V-440V , Instrument Cabinet, Material- Aluminium, Size / Dimension- ( H ) 1800 X ( W ) 900 X ( D ) 400 Mm, Finishing- Polished, Number Of Doors- 2 Doors, Lockable, Thickness- 1 Mm, Handle Material- Aluminium , Nebulizer, Usage / Application- Hospital, Operation Mode- Table Top, Type- Soft Mist Inhaler , Oxygen Cylinder, 10 Lt , Electric Orthopaedic Bone Drill Machine, One Handpiece, One Charger, Two Batteries, One Sterilizing Channel, One Drill Chuck , One Aluminium Alloy Box, Axial Run-Out Of Cincentricity Is Within 0.05Mm, Rotating Speed Of About 1100 Rpm, Rotated Torque 3.3N / M , Bone Cutter, Material- Stainless Steel, Length- 9 Inch, Steel Grade Ss410, Surface Finish- Dull, Working Type- Double Action , Bone Hammer, Bone Hammer- Nylon Faced, Material- Stainless Steel, Handle Material- Fiber Handle , Bone Holding Forceops, Type- Surgical Equipments, Material- Stainless Steel, Size- 150 - 280 Mm, , Cow Anti Kick Bar, Automation Grade- Manual, Weight-1.7 Kg , Electrical Dehorner, Material- Stainless Steel, -With 24 Volt Safety Transformer, -Including Dehorning Tip Ø 18 Mm, -Very High Heat Release , Electrical Plaster Cutter, Blade Size-42.5 Mm And 62.5 Mm, Includes- 1Spanner And 2 Blades , Digital X-Ray Machine , High Frequency X-Ray Machine Suitable For General Radiography. X-Ray Generator: - High Frequency X-Ray Generator Having Frequency Of 110Khz Or More Should Be Provided. - Power Output Of Generator Should Be 4.2Kw. - Radiographic Kv Range Should Be 40 To 120Kv. - Ma Range ( Rad. ) : 110Ma Or More. - Exposure Time ( Rad. ) : 9 Ms To 5Sec. - Mas Range ( Rad. ) : 1 To 200Mas. Control: Attractive And Ergonomically Designed Control Panel With Total Soft Touch Switches For Various Operations. Having Following Functions & Indications. • Machine On / Off Switch • Digital Display Of Kv And Mas. • Kv And Mas Increase And Decrease Switches. • Ready And X-Ray On Switch With Indicators • Bucky Selection Switch. • Stand By And Exposure Release Switch. • Self Diagnostic Program With Indicators For:- ? Earth Fault Error ? Kv Error ? Filament Error ? Tube Head Thermal Overload. • X-Ray On Indicator. • Incoming Voltage Indicator. • Anatomical Programming Up To 216 Pre-Programmed Functions In Which Automatic Selection Of Technical Factors Is Done According To The Body Part Selection. A 2-Step Hand Switch With Dual Action For Exposure Release With Retractable Cord Should Be Provided For Taking Images From A Safer Distance. X-Ray Tube: • Mono-Block Version X-Ray Tube Head Should Be Provided. The Mono-Block Consists Of Stationary Anode X-Ray Tube, H.V. Transformer, Filament Transformer, H.V. Rectifiers And Capacitors, All Immersed In High Grade Oil With High Dielectric Strength. Mono-Block Tube Head Should Be Protected For Thermal Overload. • Manual Lbd ( Light Beam Diaphragm ) With Should Be Provided With Provision Of Auto Shutoff. Stand: Mobile Stand With 4-Wheel Design, Which Ensures Easy Mobility And Steering. The Spring Balance Stand ( With Fixed Tube Head Column ) Should Be Very Light In Weight With Tube Arm, Which Is Very Easy To Maneuver And Allows Smooth Movements Of Tube Head In Vertical Plane. Lead Lined Cassette Storage Box. This Mobile Stand Is Made To Withstand All Jerks While In Use Offering Unparalleled Reliability. Sbm Stand Can Be Easily Moved On Floor And Lock Should Be Provided To Lock Its Movement On Floor. The Equipment Occupies Minimum Floor Area And Is Capable To Be Taken Through Elevators With Ease. Power Requirement: Single Phase 230V, Ac And 50 Hz., 15 Amps With Line Regulation Of ±10%. Other Requirements: • The Company Should Be Iso And Icmedcertified. • The Unit Should Be Approved By Aerb. • The Unit Should Beeuropean Ce Certified From Notified Body. • The Company Should Have A Local Service Center. • The Company Should Have Proven Track Record In Govt. Sector. , Dryview Laser Imaging Film • Blue 7-Mil Polyester Base • Daylight-Load Film Cartridges • 125 Sheets / Cartridge Choice Of Film Sizes • The Dryview 5700 Laser Imager Should Support The Following Film Sizes 14 X 17 Inch ( 35 X 43 Cm ) 11 X 14 Inch ( 28 X 35 Cm ) 10 X 12 Inch ( 25 X 30 Cm ) 08 X 10 Inch ( 20 X 25 Cm ) Automatic Image Quality Control ( Aiqc ) • Should Ensure Consistency From Film To Film • Automatic With No User Intervention Network Connectivity • Integrated Dicom Interface Should Support Printing From Dicom Print Modalitites Network Connection • 10 / 100 / 1000 Base-T Ethernet Connection To Mange ( Should Support Jumbo Frame ) Dicom Sop Classes Supported • Basic Grayscale Print Mangement Meta Sop Class • Basic Color Print Management Meta Sop Class • Presentation Lut Sop Class • Basic Automation Box Sop Class • Verification Sop Class Dimension / Weight • Height: 19 Inch ( 47 Cm ) • Width: 24 Inch ( 61 Cm ) • Depth: 26 Inch ( 66 Cm ) • Weight: 120 Lbs. ( 54 Kg ) Power • 100-120 Vac; 50 / 60 Hz • 200-240 Vac; 50 / 60 Hz Operating Environment • Temperature: 59 To 91° F ( 15 To 33° C ) • Humidity 20 To 80% Rh, Non-Condensing • Magnetic Field < 50 Gauss • Altitude:-100 To 10000 Ft ( -30.5 To 3048 Mts ) User Interface • Simplified User Panel • User Documentation And Languages Supported: - English ( Uk ) - English ( Usa ) , X Ray Flim Viewer, Specification • Luminance: Max 100000 Cd / M² • Film Density: Max 4.0 D According To En 25580 / Astm E 1390 • Control Range: 1 – 100% • Viewing Screen: 225 X 80 Mm ( 10 X 24 Cm ) • Rated Power: 70 W • Power Supply: 90 – 264 V Ac / 24 V • Dimensions: 315 X 62 X 150 Mm • Lifetime Of Leds: 40000 H • Colour Temperature Of Leds: 5000 K • Housing: Anodized Aluminium Profile With Cooling Fins – Completely Closed To The Environment • Viewing Screen: Crystal Glass With 95% Translucency, Thermally Cured, Anti-Reflective Coating

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-11-2022 Date and Other Corrigendum Date 15-12-2022

Key Value

Document Fees
INR 5600 /-
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail