Renovation Of Existingair Conditioning System Byproviding, Installation And Commissioning Of New Air Conditioning Machines & Others Related Materials In / C 3 ( Three ) Years Comprehensive Annual Maintenance Contractfor Auditoriumofsukanta Acadamy, Agartala, Tripura ( 2Nd Call ) .-Providing For Installation, Commissioning Of Air Cooled Microprocessor Based Minimum25 Tr ( Minimum 87.9 Kw ) Chiller Condensing Unit Offollowing Capacity With Hematic Scroll Compressorhaving Tandem Compressordesign 15-20% Energy Saving At Part Load, Run Time Equaliser, Operating On 3-Phase / 50 Hz / 380-415V, Maximum, Outdoor Unit Shall Be Factory Assembled Weather Proof Casing Constructed From Heavy Gauge Mild Steel, The Outdoor Unit Should Contain Error Code Diagnosis Function For Ease Of Operation, The System Should Be Equipped With Eco-Friendly Refrigerant 407C / R 410A Or Equivalent, The Outdoor Units Shall Be Complete With All Safety Devices Etc. And Also Dismantling Of Existing Chiller Plant, Ahu With It’S Existing Copper Pipe & Fittings, Sheet Metal And Related All Accessories ( Unserviceable ) And Disposal Of All Old Unserviceable Materials From The Site Through By Back System Etc. Complete As Per Direction Of The Engineer-In-Charge. 2 Providing For Installation, Commissioning Of Minimum 10000 Cfm Capacity With 60 Mm Static Pressurefor 25 Tr , Floor Mounted Type Double Skinned Air Handlingunit Compatible With25 Tr ( 87.9 Kw ) Chiller Condensing Outdoor Unit, Consisting Of 43 ± 2 Mm Thick Puf Insulated Aluminium Section Frame Construction With Necessary Dampers And Thermalbreak Profile A ) Fan Section Didw Backward Curve Imported Fan Mk. Krugar / Nikotra , The Ahu Shall Consist Of Tefc Squirell Cage Induction Motor B ) Coil Section With 6 Row Deep ( 0.41 Mm Thick ) With Air Cooled Cooling Coils With Washable Pre Filterswith 90% Efficiencydown To 10 Micronsc ] Tefcsq. Cage Induction Motord } Sandwiched Ss Drain Pand ) Hydrophilic Fin With Fin Spacing 1.4 Mm Complete With Copper Tube ( Copper Tubes Should Be Of Is Standard, , Maximum Noise Level: 50 Or Bellow Db, The Unit Must Be With Highly Acoustic Insulation, E ) Controller Set: Corded Controller With Temperature Display And Control Option ( Make: Edgetech, Zeco, Ravi Aircon, Carrier Complete As Per Direction Of The Engineer In Charge. 3 Lifting, Shifting, Positioning & Fitting Fixing Of Outdoor& Indoor Unit ( Ahu ) 25Treach, On Rcc Support / By Providingms Structure & Ahuto Be Fitted At Respective Hall ( Ahu Room ) In / Cproper Rigid Clamping Cu Refrigerantpipe Line , Communication Cable ( Through Pvc Enclosure ) Between Outdoor & Indoor Units, & Also The Necessary All Electrical Connections To Be Connected In Thebothunits From Power Supplyby Cables ( Only Fitting Fixing ) In / C Gas Charging ( Only Labour ) , Leak Testing, Pressure Checking By Providingnitrogen , Commissioning & Testing Etc. Completeas Per Direction Of The Engineer In Charge. 4 Designing, Fabrication & Erection Ofgi Sheet Metal Ducting In / C Providing Necessary Flanges, Gaskets, Bracings And Supports Complete As Per Direction Of The Engineer In Charge.22 G 5 24 G 6 Supply & Erection Of Thermal Insulation With 13 Mm Thicknitrale With Aluminum Foel Complete As Per Direction Of The Engineer In Charge 7 Supply & Fixing Of Duct Acoustic Insulation ( Sound Absorbtion Capacity ) With Minmum10-13 Mm Thick Open Cell Nitralerubber ( Inside ) In / C28 G Alluminium Perforated Sheet Complete All Necessary Fitting Arrangement Complete As Per Direction Of The Engineer In Charge. 8 Providing For Fitting Fixing Of Different Sizes Of Hard Drawn Pure Copper Refrigerant Pipewith Cooper Fittings, Tube Insulation Of 19Mmfor Connection Of Ahu Along With ItS Fittingsetc. Complete As Per Direction Of The Engineeer In Charge. ( Make: Mandev / Rajco / Maxflow ) 15.9 Mm ( 5 / 8 Inch ) 9 34.9 Mm ( 1-3 / 8 Inch ) 10 Providing & Installation Of 25Mm Nb Pvc Drain Piping Complete As Per Direction Of The Engineer In Charge 11 Providing & Connecting Electric Control Cables Between Indoor & Outdoor, Machine Room Supply Point To Indoor Machine Suitable Cablefor 3Phase Line In / C Nutral Etccomplete As Per Direction Of The Engineer In Charge 12 Supply & Erection Of Fire Retardant, Double Layer Canvasconnection Complete As Per Direction Of The Engineer In Charge. 13 Providing & Installation Vi Pad For Outdoor Unit Complete As Per Direction Of The Engineer In Charge. 14 Providing & Installation Motorised Fire Dampers With Fusible Link Complete As Per Direction Of The Engineer In Charge 15 Sand Cement Plastering ( 1:4 ) Of The Outside Duct In / Cwraping Chicken Wire Mesh On The Insulated Duct & Necessary M.S.Angle Support As Per Direction Of The Engineer In Charge 16 Supply & Erection Of Thermal Insulation With 50 Mm Thick Thermocol Slab / 19 Mm Nitralefor Out Side Duct Complete As Per Direction Of The Engineer In Charge 17 Providing Fitting Fixing Of Thermal Insulation Of 50 Mm Thick Resin Bonded Fiber Glassinsulation Covered Tissue Board Or32 Mm Xpl Sheet On The Wall And Ceiling Fixed With Frame Work With Gi Channel Covered With 26G Al Perforated Sheet And Finaly Fixing With Al Flat In Complete As Per Direction Of The Engineer In Charge 18 Providing & Fitting Fixing Of Of Electronic Expansion Valve For 25 Tr With Hand Shut Valve, Silica Dryer Filter With Suported Gi Tray Of The Same As Per Site Requirement ( Danfoss / Sporlan Make ) Complete As Per Direction Of The Engineer In Charge 19 Providing For Fitting Fixing Of Pvc Conduit Communication Cable , Size 2C X 1.5 Sqm Mm Dia Etc. Complete As Per Direction Of The Engineer-In-Charge 20 Providingof Refrigerant Gas 410 / R-410 A / 407 C As A Standard Requirement For Charging Etc. Complete As Per Directionof The Engineer-In-Charge 21 Comprehensive Annual Maintenance Contract After 1 Year Warranty Period Comprehensive Annual Maintenance Contract In 2Nd Year 22 Comprehensive Annual Maintenance Contract In 3Rd Year 23 Comprehensive Annual Maintenance Contract In 4Thyear