| 1 | SH-I: DSITC OF SPV MODULES AND PCU |
| 2 | Sl.No. 1: Design, Supply, Installation, Testing and Commissioning of 370 KW (AC Output at Inverter Side) SPV PP by Polycrystalline Solar PV Modules of each power rating not less than 340 Wp and efficiency not less than 15%at STC conforming to relevant IEC Codes with up-to-date amendments, Cells fixed in anodized Aluminium Frame with high transmission Glass provided with anti glare coating, Modules fixed on suitable Module Mounting Structure made of GI Channels with fasteners withouttracking including levelling, excavation, RCC Pile Foundation made of M20 Grade CC not less than 2 Mtr Depth (1.6 Mtr BGL and 0.4 Mtr AGL and Circular Dia of 0.30 Mtr), connecting Modules with not less than Single Core 4 SQMM 1500 V PV Copper Wire to form a Array-String, providing and fixing of suitable size IP 65 DC Outdoor Type DB/JB for connecting the Module Output with the provision for Isolation, String Monitoring and Control for each String including suitable foundation for DC DB/JB, providing and laying of DC Cabling not less than Single Core 90 SQMM (1.5 KV)Copper Cable of suitable Runs from the DC DB/JB to Inverter in50 mm dia heavy duty UPVC Pipe including trenching upto 75 CM depth, Termination of Cables with glands and lugs, Earthing of Modules and Structures throughout with 25 X 5 MM GI Strip, Painting of Structures, Marking of DC Cable Routes etc., as required.All as Above. |
| 3 | Sl.No. 2: Design, Supply, Installation, Testing and Commissioning of Total Capacity of 500 KW Power Conditioning Unit/Grid Connected Photovoltaic Outdoor Type IP 65 String Inverter of each Capacity not less than 100 KW with 20% Overloading conforming relevant IEC Codes with up-to amendments, suitable to operate on DC Input of 1000V and to deliver the AC Output of (400/415/440) V [As Per OEM/Design] on 3 Phase, 50 Hz, 3 Wire System including connection, interconnections, earthing, etc.. as required and each String Inverter comprising of the following: CompartmentalizedMetal Enclosure made out of 14 SWG CRCA Sheet with Powder Coating, DC Copper Bus, DC Switches, MFM in DC Side, MPPT (Maximum Power Point Tracker), IGBT/MOSFET Switching Devices, Microprocessor Based Control System, Synchronization Monitor and Control, Protection against Over Current, Over Temperature, DC Bus Over Voltage, Cooling Fan Failure, Anti-Islanding, DC Reverse Polarity, AC & DC Short Circuit and Over Current, AC & DC Over Voltage and Temperature, AC & DC Under Voltage and Thermal Overloading, System of Insulation Monitoring of PV Arrays, Copper AC Bus, MFM in AC Side, 250 Amps MCCB to Supply Output Power.All As Above |
| 4 | Sl.No. 3: Design, Supply, Installation, Testing and Commissioning of a Solar Radiation and Environment/Weather Monitoring System (WMS) to monitor and communicatethe Parameters Like Global Horizontal Irradiance – Pyranometer, Collector Plane Irradiance – Pyranometer, Ambient Temperature, Module Temperature, Wind Speed and Direction, Relative Humidity Rain Fall/Precipitation including providing and fixing of requisite Instruments/Sensors/Computer Hardware and Software etc., as required. |
| 5 | Sl.No. 4: Design, Supply, Installation, Testing and Commissioning of SCADA System for SPV PP for Local and Remote Web Based Monitoring to Monitor / Communicate and Control as applicable for Environment Monitoring System/PV Modules/String Monitoring Unit/Inverter/DC-AC Switch Gears/LT Panels for Electrical Parameters and Weather Parameters including providing and fixing of requisite Computer Hardware and Software etc., as required. |
| 6 | Sl.No. 5: SITC of 5 KVA UPS along with suitably designed VRLA Battery having minimum back up time of 1 Hour with MS Racks for SCADA System including providing and fixing Copper Wiring (with suitable size Cable) for Input and Output Cabling, termination etc., as required. |
| 7 | Sl.No. 6: Carrying out of Glare Analysis and Reflection Analysis for Airport Operation with respect to positioning of PV Modules, Submission of Reports, Assisting AAI in getting NOC/Clearance from AAI NOC Wing/DGCA/Other Statutories Bodies related to Safety,Recommendation for suitable installation Procedure forSafe Operation of Aircrafts etc.,as required. |
| 8 | SH-II: SITC OF LT PANELS |
| 9 | Sl.No. 7: Fabrication, Supply, Installation, Testing and Commissioning of MV Switch Board (LT AC Combination Panel) Outdoor Double Door Type Feeder Pillar made out of 3mm Thick CRCA Sheet Steel for Outer Shell and 2mm Thick CRCA Sheet forInner Partition, dust tight, vermin proof, Totally enclosed, cubicle type, free standing, provided with rain guard on top, suitable for operation at 433 V, 3 Phase, 4 Wire, 50 Hz, A.C.System complete with all accessories, interconnection, connection, earthing, painting, provision of bottom base channel and locking arrangements, grouting, making RCC Pedestal (60 CM BGL and 40 CM AGL) etc., as required and comprising of the following: |
| 10 | A) One No. of 1000 A, 65 KA, 4P ACB with Microprocessor Based Releases for OC/SC/EF Protection as INCOMER (w r t Grid) / OUTGOING (w r t Solar from Inverter Combined Output) with Resin Cast C.T. operated Digital Meter [EM6400 of Conzerve/Equivalent], ON/OFF/TRIP Indication Lamps and Phase Indication Lamps, as required. |
| 11 | B) Five Nos. of 250 A, 50 KA, 4P MCCB with Microprocessor Based Releases for OC/SC/EF Protection andROM as OUTGOING (w r t Grid) / INCOMER (w r t Solar from Individual Inverter) with Resin Cast C.T. operated Digital Meter [EM6400 of Conzerve/Equivalent], ON/OFF/TRIP Indication Lamps and Phase Indication Lamps, as required. |
| 12 | C) One Set of 1200 Amps Al. Bus Bars with at Par Neutral BUS BARS as required. |
| 13 | D) All Controls and Monitoring for smooth Transfer of Power from SPV PP to AAI SS. |
| 14 | E) All accessories such as fuses, auxillary contactors, auxillary switches, etc. as required. |
| 15 | ALL AS ABOVE 7 (A) To (E) |
| 16 | Sl.No. 8: Fabrication, Supply, Installation, Testing and Commissioning of MV Switch Board Outdoor Double Door Type Feeder Pillar made out of 3mm Thick CRCA Sheet Steel for Outer Shell and 2mm Thick CRCA Sheet forInner Partition, dust tight, vermin proof, Totally enclosed, cubicle type, free standing, provided with rain guard on top, suitable for operation at 433 V, 3 Phase, 4 Wire, 50 Hz, A.C.System complete with all accessories, interconnection, connection, earthing, painting, provision of bottom base channel and locking arrangements, grouting, making RCC Pedestal (60 CM BGL and 40 CM AGL) etc., as required and comprising of the following: |
| 17 | A) One No. of 200 A, 50 KA, 4P MCCB with Microprocessor Based Releases for OC/SC/EF Protection andROM as INCOMER with Resin Cast C.T. operated Digital Meter [EM6400 of Conzerve/Equivalent], ON/OFF/TRIP Indication Lamps and Phase Indication Lamps, as required. |
| 18 | B) Two Nos. of 125A, 36 KA, 4P MCCB with TM Based Releases for Protection and ROMas Outgoings,with ON/OFF/TRIP Indication Lamps and Phase Indication Lamps as required. |
| 19 | C) Four Nos. of 32A, 4P MCBs as Outgoings as required. |
| 20 | D) 2 Nos. of DOL Starter for 2 HP Submersible Pump withsingle phasing preventer, volt meter, ammmeter, O/L relay, etc., as required. |
| 21 | E) One No. 5 KVA UPS along with suitably designed VRLA Battery having minimum back up time of 1 Hour with MS Racks in a separate Compartment for InverterControls/WMS Controls including providing and fixing Copper Wiring (with suitable size Cable) for Input and Output Cabling, DC DB with 16 A DP MCB as Incoming 4 Nos. 6 A DP MCBs as Outgoing, Termination etc., as required. |
| 22 | F) One Separate Compartment (with proper magnetic isolation) having RTU and Accessories for Data Collection from Inverters, LT AC Combination Panel, WMS etc., comprising of PLC, Network Interface Module, Power Supply Module, AI Module, DI/DO Module, SPD, LIU, Patch Card, Media Converter etc., including providing and fixing Wiring for InputCabling from Inverters, LT AC Combination Panel, WMS , Termination etc., as required. |
| 23 | G) Two Nos. of Empty Space to accommodate 63 A, 36 KA, 4P MCCB at later stageas required. |
| 24 | H) One Set of 400 Amps Al. Bus Bars with at Par Neutral BUS BARS as required. |
| 25 | I) All accessories such as fuses, auxillary contactors, auxillary switches, etc. as required. |
| 26 | ALL AS ABOVE 8 (A) to (I) |
| 27 | Sl.No. 9: Fabrication, Supply and Installation of Inverter Enclosure of Outdoor Double Door Type Feeder Pillar made out of 3mm Thick CRCA Sheet Steel, dust tight, vermin proof, Totally enclosed, cubicle type, free standing, provided with rain guard on top,complete with all accessories,earthing, painting, provision of bottom base channel and locking arrangements, grouting, making RCC Pedestal (60 CM BGL and 40 CM AGL) etc., as required. (Item No. 2 Each String Inveter will be housed in this Enclosure for Rain Protection). |
| 28 | SH III CABLING WORKS. SH III (A) SUPPLY OF CABLE |
| 29 | Sl.No. 10: Supplyof XLPE insulated and PVC sheathed AluminiumConductor armoured power cable of 1.1 KV grade conforming to IS 7098 (Part-I) 1988 as amended upto date and of following size as required: |
| 30 | A) 3.5 X 400 SQ MM |
| 31 | b) 3.5 X 240 SQ MM |
| 32 | SH-III (B):CABLE LAYING AND ASSOCIATED WORKS |
| 33 | Sl.No. 11: Laying of one number PVC/XLPE insulated and PVC sheathed power cable of 1.1 KV grade of size exceeding 185 sqmm but not exceeding 400 sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc.. as required. |
| 34 | Sl.No. 12: Laying of one number PVC/XLPE insulated and PVC sheathedpower cable of1.1 KV grade ofsize exceeding 185 sqmmbut not exceeding 400 sqmm.in the existing RCC/Hume/STONEWARE/METAL/HDPE pipeas required. |
| 35 | Sl.No. 13: Laying of one number PVC/XLPE insulated and PVC sheathed power cable of1.1 KV grade of size exceeding 185 sqmmbut not exceeding 400 sqmm in the existing masonaryopen duct as required. |
| 36 | Sl.No. 14: Laying and Fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) on the existing cable tray as required. |
| 37 | Sl.No. 15: Supplying and laying of 125 mm OD HDPE Pipe of PE 80 PN 6 ISI Markedwith all accessoriesconforming to IS 4984complete with fitting and cutting, jointing etc.,direct in ground (1.2 mtr below the ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as required. |
| 38 | Sl.No. 16: Supplying and laying of 100 mm OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories conforming to IS 4984complete with fitting and cutting, jointing etc.,direct in ground (1.2 mtr below the ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as required. |
| 39 | Sl.No. 17: Supplying and laying of125 mm OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories conforming to IS 4984complete with fitting and cutting, jointing etc.,direct in ground (1.2 mtr below the ground level) in the existing trench as required. |
| 40 | Sl.No. 18: Supplying and laying of \"B\" Class G.I pipe of 150 mm dia, i/c excavation of bituminous/concrete road/pavement, excavation of Soil up to the Depth of 1.20 Mtrs from ground, refilling the Soil and with CC of ratio 1:3:6 on top for 0.15 Mtrs after laying Pipe and plastering, making good thesame etc., as required. |
| 41 | Sl.No. 19: Supplying and installing following size of perforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors, suspendedfrom the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc asrequired. A) 300 mm (W) X 62.5 mm (D) X 2.0 mm Thickness. |
| 42 | Sl. No. 20: Horizontal Direction drilling of Soil/Rock by excavation of Pits on both sides of crossings , boring of Minimum 160mm dia, minimum depth of 4 Metresand Providing and laying of 160 mm HDPE pipe of PN 10 and PE 100 Grade etc.,complete as required. (2 Nos. of Independant Runs of 90 Meter Each). |
| 43 | Sl.No. 21: Dismantling of Bituminous/CONCRETE road including disposal of debris, etc as required. |
| 44 | Sl.No. 22: Construction and Supply of Pre-Cast RCC Manhole Chamber of Internal Dimension 1MX1MX1M (External 1.2MX1.2MX1.2M) with CC of 1:2:4 of thickness 100mm with Square Top Cover of 600X600mm size with L angle reinforced at all side of top and bottom of cover, lifting hook including finishing with Cement Coat as required. |
| 45 | Sl.No. 23: Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 46 | 3.5 X 400 SQ MM |
| 47 | 3.5 X 240 SQ MM |
| 48 | Sl.No. 24: Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 49 | 3.5 X 400 SQ MM |
| 50 | 3.5 X 240 SQ MM |
| 51 | Sl.No. 25: S/F GI cable route marker Supplying and making cable route marker with 10cm x 10 cm x 5 mm thick G.I plate with inscription thereon bolted/ welded to 35 mm x 35mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 52 | Sl.No. 26: Supply of nominal 2.0 mm thick (Width 1 Mtr) PVC synthetic, electric insulated mats conforming to IS 15652-2006 having Dielectric strength of 30 KV, no adverse effect of mineral oil, high insulation resistance (Minimum 1,00,000 M ? on wet condition with 5 KV meggar) etc., as reqd. |
| 53 | Sl.No. 27: Fixing of nominal 2.5/2.0 mm (Width 1 Mtr) thick PVC synthetic, electric insulated mats conforming to IS 15652-2006 along with suitable adhensive/chemibond, i/c providing water proofing of floor, (chipping of floor if required) sealing of all joints etc., as reqd. |
| 54 | Sl.No. 28: Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. (Inverter Body Earthing) |
| 55 | Sl.No. 29: Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)-(Module Strucure Continuous Earthing is not covered). |
| 56 | Sl. No. 30: Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required-(Module Strucure Continuous Earthing is not covered). |
| 57 | Sl. No. 31: Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required-(Module Strucure Continuous Earthing is not covered). |
| 58 | Sl.No. 32: Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, GI tube, having single prong at top, with 85 mm dia 6 mm thick GI base plate including holes etc. complete as required. |
| 59 | Sl. No. 33: Providing and fixing of lightning conductor finial base support, made of 40 mm dia 2000 mm long, FRP Pole fixed on 40 mm dia 1500 mm long, GI C Class Pipe, including providing 10 mm MS Base Plate, Tie Wire, RCC Foundation (1 Mtr Height-60cm BGL and 40 cm AGL) etc. complete as required. |
| 60 | Sl.No. 34: Providing and laying G.I. tape 32 mm X 6 mm from finial on surface as required. |
| 61 | Sl.No. 35: Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 62 | Sl.No. 36: Providing and fixing testing joint, made of 32 mm X 6 mmG.I. strip, 125 mm long, with 4 Nos. of GI bolts, nuts,check nuts and spring washers etc. complete as required.thick. |
| 63 | Sl.No. 37: Providing & fixing of Carbon-dioxide (CO2) Type fire extinguishers conforming to IS 2878-1976 and cylinder fully charged of 4.5 Kg capacityas required. |
| 64 | Sl.No. 38: Supply and fixing of foam type fire extinguishers [Portable Type of 9 Litre Capacity]as required. |
| 65 | Sl.No. 39: Supply and fixing of Safety Instruction Chart (in words) dulyframed with 5mm thick glass complete as required. |
| 66 | Sl.No. 40: Providing & fixing a set of 4 Nos. 9.5 Litre capacity GI bucketpainted in post office red colour and written with white paint\"Fire\" and mounted on MS angle iron frame with bracket ofappropriate size and capacity including filling sand completeas required. |
| 67 | Sl.No. 41: Providing & fixing of First Aid Box as approved by St. JohnAmbulance Brigade/Indian Red Cross conforming to IS 2217-1963 as required. |
| 68 | Sl.No. 42: ProvidingCivil Worksas required as detailed below: |
| 69 | A) Cement concrete in 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 70 | B) Cement mortar in 1:6 (1 cement: 6 coarse sand ) |
| 71 | C) Brick work with bricks of class designation 60 in foundation and plinth in 1:6 (1 cement: 6 coarse sand) |
| 72 | D) Cement plaster 12mm thick of mixture 1:6 |
| 73 | E) Steel rod for RCC Slabs |
| 74 | SH-III (C):OFC CABLE LAYING AND ASSOCIATED WORKS |
| 75 | Sl.No. 43: Supply of 06 F OFC of Single Mode, armoured, multi tube, double sheath, suitable for outdoor application conforming to ITU-T-G652 & IEC60973 & 60794 with up-to date amendments as required. |
| 76 | Sl.No. 44: Supply of Permanently Lubricated HDPE Pipe of 40 mm Outer dia and 33 mm inner dia made ofPE 63 Material and suitable for PressurePN 6 as required. |
| 77 | Sl.No. 45: Laying of 1 No. of 40 mm DN PLB-HDPE Pipe by Single Horizontal Drilling of suitable Diawith minimum depth of 4 Mtr including Opening of Manholes, reaming, providing all required Machinaries and Specialised Manpower as required. |
| 78 | Sl.No. 46: Laying of 2 Nos. of 40 mm DN PLB-HDPE Pipe by Single Trenching to the depth of 1.20 Mtr including excavation, refilling the trench etc.. as required. |
| 79 | Sl.No. 47: Supplying and laying of \"B\" Class G.I pipe of 100 mm dia, i/c excavation of bituminous/concrete road/pavement, excavation of Soil to maximum depth of 1.20 Mtrs from ground refilling the Soil and with CC of ratio 1:3:6 on top for 0.15 Mtrs after laying Pipe and plastering, making good thesame etc., as required. |
| 80 | Sl.No. 48: Laying of 2 Nos. of 40 mm DN PLB-HDPE Pipe in the existing GI Pipe as required. |
| 81 | Sl.No. 49: Laying of 2 Nos. of 40 mm DN PLB-HDPE Pipe in the existing Open Duct Pipe as required. |
| 82 | Sl.No. 50: Laying [by Pulling/Blowing] of OFC of up to 24F in the existing PLB-HDPE Pipe, Sealing of Pipesetc., as required. |
| 83 | Sl.No. 51: Laying [by Pulling/Blowing] of OFC of up to 24F in the masonry Open Duct/Manhole Chamber/Junction Boxesetc., as required. |
| 84 | Sl.No. 52: Supply and making of splicing joint of06 F OFC including providing all accessories and SpecialisedManpower complete as reqired. |
| 85 | Sl.No. 53: Supply and making of splicing and termination of 06 F OFC inTerminal box including providing all accessories and SpecialisedManpower complete as reqired. |
| 86 | Sl.No. 54: Acceptance Testing (OTDR)of06 F OFC including providing all Testing Instrumentsand SpecialisedManpower complete as reqired. |
| 87 | SH:IV ANCILLARYWORKS |
| 88 | Sl.No. 55: SITC ofsubmersible pump set of 2 HP capacity (with suitable size delivery Pipe up to 10 Mtr) suitable for operation on 415 V, 110 m Head and able to discharge minimum 20 LPM complete as required. |
| 89 | Sl.No. 56: Supply of Flat Three Core x 4.0 Sq.mm PVC insulated & PVC sheathed, Copper conductor Industrialcable of 1.1 KV grade confirming to IS - 694for Submersible pump motors, complete as required. |
| 90 | Sl.No. 57: Supply of 4 Core x 10 Sq.mm Cable of XLPE insulated, PVC sheathed, Aluminium conductor armouredpowercable of 1.1 KV grade confirming to IS - 7098 PART- I with upto date amended etc., as required. |
| 91 | Sl.No. 58: Laying of one number PVC/XLPE insulated and PVC sheathedpower cable of1.1 KV grade ofsize upto 35 Sqmm in the existing RCC/Hume/STONEWARE/METAL/HDPE Pipeas required. |
| 92 | Sl.No. 59: Supplying and laying of50 mm OD HDPE Pipe of PE 63 PN 6 ISI Marked along with all accessories conforming to IS 4984complete with fitting and cutting, jointing etc.,direct in ground (0.75 mtr below the ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as required. |
| 93 | Sl.No. 60: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. a) 4 X 10 sq.mm |
| 94 | Sl.No. 61: Providing and fixing of IP 65 Junction box with connector as required (Near to submerssible pump). |
| 95 | Sl. No. 62: Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required. |
| 96 | SH-V:APPROVALS |
| 97 | Sl.No. 63: PreparationofDrawings,Calculations, Necessary Data, Deposit of Necessary Statutory Fees and Liasoning Work for getting Approval and obtaining sanction for energization of Solar PV system and associated Electrical Systemfrom Central Electricity Authority/EB/Any other Nodal Agency of Central/State Government as required. |
| 98 | SH- VI : O & M AND CAMC |
| 99 | Sl.No. 64: Facility Management Contract for Monitoring & GENERAL Maintenance ofGrid Connected 370 KW SPV PP and existing 130 KWp (80 KWp at Fire Station and 50 KWp at Main Power House) at Imphal Airport comprising of Solar PV Modules, DC DBs/JBs, Power Conditioning Units, String Monitoring Units, Lightning and Earthing Protection System, AC DC Cables, SCADA System, Weather Monitoring System, LT Panels etc., with One Skilled Person and One Helper on General Duty on Day Time as per the direction of EIC, Monitoring Control and Maintenance for 100% Serviceability including Co-Ordination withMain Sub-Station of Terminal Building including Routine Cleaning of Modules as required. |
| 100 | A) I YEAR-DLP |
| 101 | B) II YEAR-DLP |
| 102 | C) III YEAR |
| 103 | D) IV YEAR |
| 104 | E) V YEAR |
| 105 | F) VI YEAR |
| 106 | G) VII YEAR |
| 107 | H) VIII YEAR |
| 108 | I) IX YEAR |
| 109 | J) X YEAR |
| 110 | K) XI YEAR |
| 111 | L) XII YEAR |
| 112 | Sl.No. 65: All Inclusive Comprehensive ANNUAL Maintenance Contract ofGrid Connected 370 KW and existing 130 KWp (80 KWp at Fire Station and 50 KWp at Main Power House) SPV PP at Imphal Airport as per the Technical Specification as required.[FIRST2 YEARS WILL BE DLP]. |
| 113 | A) III YEAR |
| 114 | B) IV YEAR |
| 115 | C) V YEAR |
| 116 | D) VI YEAR |
| 117 | E) VII YEAR |
| 118 | F) VIII YEAR |
| 119 | G) IX YEAR |
| 120 | H) X YEAR |
| 121 | I) XI YEAR |
| 122 | J) XIIYEAR |
| 123 | Sl.No. 66: All Inclusive Comprehensive ANNUAL Maintenance Contract ofGrid Connected existing 130 KWp (80 KWp at Fire Station and 50 KWp at Main Power House) SPV PP at Imphal Airport as per the Technical Specification as required. |
| 124 | A) I YEAR |
| 125 | B) II YEAR |