| 1 | Supply, Installation, Testing and Commissioning of200 KVA capacity “IECO” Make Servo Controlled, Voltage Stabilizer factory assembled floor mounted, of capacity 200 KVA, complete,(As per BIS 9815) with safety control and metering equipment mounted on common, base frame comprising of following complete all as specified and as directed with the Make- Instruments & Equipment Co/Make ITE Gurgaon/ Jaybee Bathina/ Transfomers & Electriclas (Inida) following accessories:a) (a)Servo Controlled technology.b) Type – Three Phase , Indoor, unbalanced supply, unbalance load, c) Oil cooling type, d) Testing - As per IS:9815 and IS:2026,e) Input voltage – 320V-480V Ph to Ph, f) Output voltage – 415 +/- 2.5%, g) Frequency- 50Hz +/- 5%, h) Metering – Digital Microprocessor based, i) Efficiency – Not less than 98%, j) Responsible time- less than 10 mili second, k) Insulation Resistance (IR) - More than 10 Mega ohms at 500 V DC, l) Protections Provided- Over load, short circuit Protection, High/low voltage cut,, off, bypass arrangement, single phase preventer. m) 1st filling of transformer oil to be included by manufacturer complete all as specifed and as directed. |
| 2 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete all as specifed and as directed. |
| 3 | Supply and fix UPS for 30 min back up three phase AC input 300 to 450V and out put 415 V ± 1% of capacity 20KVA complete all as specifed and as directed. |
| 4 | M & L Sub main wiring with four run single core 10 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V includingCassing cappingISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion complete all as directed.Note: (i) four runs of 10 sqmm and one run of6 sqmm cable and one run of PVC casing /cappingshall be measured as one RM complete all as specifed and as directed. |
| 5 | Material and labour for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I. |
| 6 | Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, in PVC Casing capping on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitablesteel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washersand making goodthe disturbed surfaces as per existingfor one light point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately . |
| 7 | Supply and fix switch piano (ISI marked) Single pole 240 volts,5Amps all as specified and directed. |
| 8 | Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified. |
| 9 | S & F Exhaust fan 230 volts , 250mm, steel body heavy dutyincludingmaking all electric connection complete all as specified and as directed including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall complete all as specifed and as directed.Make Bajaj/Havell\"s/CG. |
| 10 | M & L for aluminum housingventilator for bathroom window with makinghole on window with aluminum partition with housing accessories and making good disturbed surface of wallfor fan fix on wall complete all as specified and directed. |
| 11 | Supply and fixing LED flood light 50 Watt, Green light pressure die cast aluminum housing, heat resistant glass, IP65 protection, better optics for uniform distribtion complete with all accessories internally pre wired and includingwith suitabe size bracket for mouting flood light (angle iron)connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of lightcomplete all as specifed and as directed..Make- Philips/CG/Havells |
| 12 | Supply and fixing LED flood light 50 Watt, Multi colour light pressure die cast aluminum housing, heat resistant glass, IP65 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including with suitabe size bracket for mouting flood light (angle iron) connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of lightcomplete all as specifed and as directed. Make- Philips/CG/Havells |
| 13 | S & F Philips 11.5 WattsSmart Lightstrip Plus with suitable size LED driver warm white and fixed in ceiling / wall with 2 Nos PVC block suitable size complete all as specified and as directedMake- Philips Cat part No- 915005240701 |
| 14 | Supply and fix MCB Distribution board , 240 volts single pole andneutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection,complete all as specified and directed. Make: Havells Cat part No DHDPSHODRW08 or equivalent in Schnieder/GE/C&S. |
| 15 | Supply and fix MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity \"C\" seriescomplete all as specified and directed |
| 16 | Supply and fixMCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB\"scomplete all as specifed and as directed. |
| 17 | Supply and fixing LEDStreet light 60 Watt, warm white type,pressure die cast aluminum housing, heat resistant glass, IP66 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including with suitabe size bracket for mouting flood light (angle iron) connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light,including service bracket complete all as specifed and as directed. Make Make:- Bajaj /CGSurya / havells . |
| 18 | Supply,laying, and testing XLPE cable insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size16 sqmm 2 core complete all as specfied and directed. |
| 19 | Excavation in trenches n exc 1.5 mtr wide and depth n exc 1.5 mtr deep for foundation, laying GI pipes and UG cables etc n exc 10 sqmtr on plan, in hard/dense soil and getting out complete all as specified and directed. |
| 20 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 21 | M & L for providing dry river sand as in sand cushioning to UG cable including punning gently complete all as specified and directed. |
| 22 | Removing excavated material not exc 50 mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 23 | Supply & lay Sub class\"B\" old size well burnt brick laid flat in trenches as protection to LT cable complete all as specified and as directed. |
| 24 | Supply and fixing GI Tubing light grade under road, on pole floor and on wall for cable protection complete all as directed for following sizes 40 MM dia bore complete all as specifed and as directed. |
| 25 | Supply and fixing Flexiable cable 6 Sqmm Weather proof single flat twin core cable including pvc pipe 20 mmcomplete all as specified and directed |
| 26 | Supply and fixing LED flood light 200 Watt,pressure die cast aluminum housing, heat resistant glass, IP65 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with suitabe size bracket for mouting flood light (angle iron) three core 1.5 sqmm flexible copper conductor cable from Junction boxto connector of lightcomplete all as specifed and as directed.Make- Philips/CG/Havells |
| 27 | M & L for Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11m long) conforming to IS-2713 (Part-I & II) including painting of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer from top of the pole to 1.5m above the bottom of the pole and painting with two coats of black bituminous paint over a coat of red oxide zinc chrome primer upto 1.5m from bottom of the pole including numbering of poles with suitable size bracket and clamps for fixing LED street light / Flood light fittings etc as directed complete all as specified and directed.(Note: Excavation and earth work and PCC shall be measured and paid separately under respective items) |
| 28 | M & L for testing, installation, commissioning of Kitchen Exhaust Systemwith SS Hood with SS 304 Bafflet, Triple layer baffle filter 6 feet , Width 40-80(cm) , 180-200(cm), Suction Capacity 800-1200(m3/h), Air Flow : 1800m3/h, Frequency : 50Hz to 6Hz, High Velocity Hood, 18 Guage Stainless Steel Duct, Duct Velocity 1750 FPM, PDCA Motor , VoltageInput 250 V, Noise Level 60db, GI Ducting for Hot air Ventilation 60 Sqft. Corrosion Resistance, Commercial Exhaust Fan18inch Dia/EPC , Commercial Exhasut fan 450 mm sweep with 1400 RPM / including all Civil work for fixing system, make hole and replastiring esxiting wall with wall colour codeing with Basic Civil work required including fixing of Duct and complete Electrical wiring. as reqruied for system runningcomplete all as specified and directed, Make - EPC |
| 29 | Supply, lay in trenches, floors ,fix on wall/pole, passing through pipes etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistrandedaluminium conductors, armoured with galvanised steel wire or tape ,gland, lugs etc, of size 70 Sq.mm 3.5 core , confirming to IS specifications:-complete all as specifed and as directed. |
| 30 | M & L for cutting exisitng bitumenous road surfaces not more than 150 mm thick, removing for laying of pipes/cables, making good with PCC 1:3:6 type C1 20 mm graded aggregate to match with the adjustant surface complete all as specifed and as directed. Note Excavation and earth work below 150 mm thick will be measured and paid under relevant items. |
| 31 | Supply, lay in trenches, floors ,fix on wall/pole, passing through pipes etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistrandedaluminium conductors, armoured with galvanised steel wire or tape ,gland, lugs etc, of size 25 Sq.mm 3.5 core , confirming to IS specificationscomplete all as specifed and as directed. |
| 32 | Supply and fix MCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified. L&T/Seimens /Legrand . (Note:MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule .Note:Copper thimble shall be used for connection of cable . |
| 33 | M & L for Sub main wiring with two runs of single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including Cassing capping , medium gradeISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed.Note: (i) Two runs of 6 sqmm and one run of 6 sqmm cable and one run of PVC casing / capping shall be measured as one RM. |
| 34 | Supply and fix MCCB TPN, 240 Volts, 100Amps, 25 kA rupturing capacity 415 Voltswith sheet metal inclosure type complete all as specified and directed |
| 35 | Supply and fix MCCB TPN, 240 Volts, 100Amps, 10 kA rupturing capacity415 Voltscomplete all as specified and directed including taking down old one. |
| 36 | Supply and fix MCB Distribution board , 240 volts single pole andneutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, complete all as specified and directed. Make: Havells Cat part No DHDPSHODRW12 or equivalent in Schnieder/GE/C&S. |
| 37 | M & L Sub main wiring with two runs ofsingle core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including Cassing capping , medium gradeISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed.Note: (i) Two runs of 4 sqmm and one run of4 sqmm cable and one run of PVC casing / cappingshall be measured as one RM. |
| 38 | Supply, install , testing and commissioning of outdoor LT distribution feeder pillar IP-65 , CPRI approved of suitable size factory made totally enclosed dust and vermin proof , double leaf shutter in front and single leaf shutter in rear made out of 3.15 mm thickCRCA sheet duly fabricated and having proper front and rear locking arrangementduly painted with powder coated paintand aluminiumbus bar 200amps, 415 volts, 50 Hz 3 phase and 4 wire system with the following items connected as underincluding supplying and fixing on MS chanel 75mmx40mmx5mm in PCC foundation and PCC work around the panel board witnin two fit area:- INCOMINGChangeover switch 200 Amps 4 pole-01(a) MCCB 4 pole 200 Amps, 415 V, 36 KA-01 No(b) LCD multifunctioning meter-01 No(c)Phase indicator Lamps (RYB phases)-01 Set (Set of Three) LED Cluster type(d) CTs 100/5 amps-set of three(e) Aluminium bus bar300 Amps-03 Nos and 150 Amsp -01 Nos() Internal Wiring for panel incl insulators, sleeves etcOUTGOING(a) MCCB 4 pole 160 Amps, 415 V, 25 KA-02 No(b) MCCB 4 Pole100 Amps, 415 V, 25 KA-01 No(b) MCCB 4 Pole63 Amps, 415 V, 25 KA-01 No |
| 39 | Material and labour for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth strip 32 x 3mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I. |
| 40 | Supply and fixing, installtion and testingof ESE Air Terminal: Supply from Global leader Duval Messien of France SATELIT 3- 45 Air terminal with external, wide area, early streamer emission (ESE) type lightning arrestor made of robust 304L stainless steel (INCLUDES TELETESTER). It is a proactive, intelligent and remotely monitored electronic device, powered by long life battery on board, which should be rechargeable with solar cells. It is capable of polarizing the tip with a voltage between 20 kV and 30 kV, synchronized with an approaching lightning and triggering a powerful upward streamer into the air, 60 microseconds earlierthan naturally formed streamers. The lightning arrestor is capablen of grounding repeat lightning strikes and both negative and positive strikes that may occur within few milliseconds of each other.Operating Principle:-1.This lightning arrester is equipped with a double device of polarization. The first “active” collects and stores the solar energy in the batteries, then charges maintain the ascending tracer propagation. An integrated sensor of current allows to measure the during a descending tracer approach in the zone of protection area. When it exceeds 1A, The sensor triggers the capacitors discharge andreleases the necessary energy to the ascending tracerpropagation, polarizing the point at a voltage between 20 and 30 kV. |
| 41 | 2support mast of robust design, made with 6 Mtr40mm dia. class B medium MS pipe duly galvanized withminimum 85 micron zinc coating, along with allaccessorires like clamps, saddles, holding arrangements,guy wire etc. to fix the mast to the shed/structure athightest point such that the Air terminal is 5 metresabove the tallest structure is installed as per siterequirement.- 01NosNOTE: Any type of Civil work is not in SGI\"s scope of work.3. Down Conductor :of 70sqmm. Multistrand Single Core Unarmoured Cu. Cable along with accesseries upto EARTH PIT.50 MtrNOTE : Down Conductor length may vary depending upon site condition and the same shall be supplied at extra cost.- 01Nos4.The second system called “passive” stores the electrostatic energy present in the atmosphere at a stormy cloud approach. The integrated sensor in the “SATELIT-3 “measures the value of theambient electric field and releases the impulsion device as for theactive part of the lightning rod. The one cause a quasi instantaneous inversion of the head polarity of the lightning rod causing a sudden amplification of the electrical field on its point. The lightning arrestor has in built self check mechanism to facilitate remote testing from a distance of 100 meters. NOTE: The Early Streamer Emission lightning conductor SATELIT |
| 42 | 5 can be tested remotely, via radio signals, with the newTeleTester-S3.The Satelit 3 has an on-board transmitter using a standard frequency and transmitting a signal every 90seconds to confirm the correct operation of the lightning conductor\"s electronics, including then polarization of its tip. The TELETESTER receives the information transmitted by the SATELIT 3 and emits and audible signal confirming the installation is fully functional. This check can be performed up to a distance of 100M between the SATELIT 3 and the Telemeter. Generation III Air Terminal:- SATELIT 3-45: Level 1 Protection upto a Radius of 63 Meters.Level 3 protection upto a Radius of 81 Meters.6. Steel Test Joint- 01 Nos7. low impedance high voltage conductor, made from highconductivity GIstrip 25mm x 6mm for pit to pit interconnection.- 10 Mtr8.Earthing Electrodeof 17.2 mm dia. copper molecularly bonded on steel electrode each 2.4m long.- 03 Nos9.U- Clamp Bolt. (Copper with Gunmetal)- 03Nos10. Earth Enhancing Chemical Compound: earth enhancing soil treatment chemical compound n\"EARTHCON\" (IEEE 80:2000 Clause 14.5b) having essential chemical ingredients, such as ionic chemicals, dispersion chemicals, expansion chemicals & hygroscopic chemicals, to provide stable low resistance for earth terminal to make it maintenance free. (12.5kg/bag)- 6 Bags.11 Earth Enhancing Chemical Compound:of earth enhancing soil treatment chemical compound \"TERRANITE\" ( TESTED AS PER IEC62561-7) having essentialchemical ingredients, such as ionic chemicals, dispersion chemicals, expansion chemicals & hygroscopic chemicals, to provide stable low resistance for earth terminal to make it maintenance free. (25kg/bag)- 03 Begs 11Earth-pit cover: of HDPE medium duty Earth pit cover to withstand a maximum of 5 Ton load.- 03 Nos12 Lightning Flash Counter: of COSMOS Lightning Flash Counter, electromechanical type, in an IP 65 enclosure, capable of registering lightning strikes of 1 kA to100 kA (8/20 micro second waveform). The counter is to be installedon the down conductor at man height for easy readability of LightningStrike count.- 01 Nos |