}

Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Water Supply Scheme Panzoo G B Of Jal Shakti ( Phe ) Mechanical Division South Awantipora Under Jjm. -Supply, Installation, Testing & Commissioning Of Submers, Kulgam-Jammu And Kashmir

Public Health Engineering Department has published Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Water Supply Scheme Panzoo G B Of Jal Shakti ( Phe ) Mechanical Division South Awantipora Under Jjm. -Supply, Installation, Testing & Commissioning Of Submers. Submission Date for this Tender is 09-11-2022. Electromechanical Machinery Tenders in Kulgam Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

34246992
Corrigendum : Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Water Supply Scheme Panzoo G B Of Jal Shakti ( Phe ) Mechanical Division South Awantipora Under Jjm. -Supply, Installation, Testing & Commissioning Of Submers
Open Tender
Indian
Jammu And Kashmir
Kulgam
09-11-2022

Tender Details

Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Water Supply Scheme Panzoo G B Of Jal Shakti ( Phe ) Mechanical Division South Awantipora Under Jjm. -Supply, Installation, Testing & Commissioning Of Submersible Pumping Unit As Per Is 8034 With Following Specification Are As Under:Pump:Discharge:2000 Gph Head: 305 Mtrefficiency= Not Less Than 50% Speed= 2900 Rpmtype Of Pump= Mixed Flow. Type Of Fluid To Be Handled = Clear Watermaterial Of Construction: Impeller = Stainless Steel Pump Shaft = Stainless Steel Ss 410.Pump Casing = Cast Iron / Stainless Steelimpeller:Impeller Is Of The Enclosed Or Semi – Enclosed Type And Properly Balanced.Enclosed Impellers Equipped With Seal Rings On Their Hubs. Coupling:A Suitable Coupling Arrangement Provided With Pump Set.Non Return Valve: - Non Return Valve Of The Suitable Size Provided Above The Pump Discharge Case.Motor:-Rating:17.5 Hpmethod Ofstarting = Star – Delta Speed = 3000 ( Sync ) .Frequency= 50 ± 3 % Hzworking Voltage = 380-415 ± 15% V, 03 Phase Efficiency = Not Less Than 90%Rating=Suitable For Above Parametersclass Of Insulation=F / Suitable For Above Parameterssubmersible Motor Should Be Water Filled Water Lubricated Squirrel Cage Type Having Capacity For Above Pumping Parameters And Working On 3 Phase; Ac Supply Ranging From 380 To 415 Volts, 50Hz. The Motor Should Be Sealed By Radial Rings To Avoid Mixing Of Well Water With Motor Filled Water. A ) The Job Includes Providing And Fitting Of Interlocking Arrangement Against Any Failure Of Coupling. It Must Be Fabricated Out Of Ms Strips Of Suitable Size And Length.B ) The Job Includes Providing And Fitting Of Appropriate Size Ms Nipple 2 Feet Long Threaded On One End And Welded To Same Size Ms Flange Ofthickness ( As Per Table-17 ) At Other End For 80 Mm Diameter Column Pipe As Per Site Requirement. The Threaded Portion Should Be As Per Size Of Pumping Out Let For Proper Fixing.The Job Includes Providing And Fitting Of R. I. Cloth Joints / Rubber Washers With Nuts, Bolts And Washers For All Joints Of Column Pipe. The Job Also Includes Lowering Of Pumping Unit In The Well Then Proper Testing And Commissioning Of Pumping Unit On Full Load At Site.Note: Providing Of Test Certificate & Characteristic Curve Of Pumping Equipment Is Compulsory And Pumping Unit Is To Be Approved From The Concerned Sub Divisional Office Before Procuring. 3 Providing / Supplying And Fitting Of 50 Mm Diameter G.Iclass B Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-B Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make.Flanges ( As Per Is 6392 / 1997 Table:17 ) Thickness Shall Conform To Is 6392 Part 1St Table-17. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint.Welding Electrodedc Arc Welding Using Welding Electrode Having Diameter Not Less Than 4Mm.Nuts And Boltsnuts And Bolts ( Conforming To Is:1363 Part 1St ) Rubber Insertion Gasketsrubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. The Rising Main Is To Be Laid As Per The Instructions Of The Engineer In Charge. 4 Earth Work In Excavation By Manual Means In Trenches For Foundation, Drains, Pipes, Cables ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed. ( All Kinds Of Soil 01 Meter From Cutting Edge ) 5 Filling Available Excavated Earth In Trenches, Plinth, Sides Of Foundation Etc.In Layers Not Exceeding 20 Cm In Depth , Consolidating Each Deposited Layer By Reaming And Watering , Lead Upto 50 M And Lift Upto 1.5M. 6 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated 50Mm Diameter Glandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .The Body And Bonnent Of The Valve Shall Be Of Ductileiron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valve Shall Be Compatible For Buried Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positionsit Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve. The Valve Shall Be Supplied Along With Hand Wheel.Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work.The Job Includes Providing And Fitting Of 02 Nos. M.S Flanges Perfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shall Be Fitted With Rising Main Of The Pumping Unit At Appropriate Spots As Per Site Requirement. 7 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seat 50Mm Diameter Swing Check Valve ( Nrv ) As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approved For Drinking Water ) . The Valve Shall Be Compatible For Buried Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positions.It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve.Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work.The Job Includes Providing And Fitting Of 02 Nos. M.S Flanges Perfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shall Be Fitted With Rising Main Of The Pumping Unit At Appropriate Spots As Per Site Requirement. 8 Fabrication, Providing And Fitting Of Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. ( 02 Pair ) 9 Fabrication , Providing And Fitting Of90-120 Degree Bend / Elbowto Be Fabricated Out Of50mm Diameter Class-C, G.I Pipe, 1 M Lengthand Flanged On Both Ends Ato Make It Leak Proof. The Flanges Shall Be M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) And Welded On Both Sides. The Job Includes Nuts, Bolts, Gaskets Etc As Per Site Requirement. 10 Providing And Fitting Of 300Mm In Length 50Mm-80Mm Dia Gi Reducer Bend Flanged On Both Sides, Flange Conforming To Table-17 ( Pn16 ) To Be Fitted With The Column Pipe / Delivery Manifold Of Submersible Pumping Unit To Join Rising-Main And Column Pipe / Delivery Manifold. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes From Inside And Outside Of Pipe To Form Strong Welding Joint. 11 Fabrication, Providing And Fitting Of Washout 50Mm Dia.Tee With Arm Length 1.2 Feet Each. The Tee Shall Be Fabricated Out Of G.I C-Class Pipe With M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends. 12 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded In All Respects As Per Drawing Appended. 13 Earth Work In Excavation Required For Installation Ofgantry Mechanismand Associated Worksby Manual Means In Trenches For Foundation , Drains , Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts , Wells , Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed In All Kinds Of Soil. 14 Providing And Laying Of Soling Stone 15 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With 1: 2 : 4 ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) . 16 Centering And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For Foundation , Footings , Bases For Columns 17 Painting Of The 2 No. Gantry And Plate Form Of Wellusing One Coat Of Red Oxide Metal Primer And Two Coats Of Enamel Paintof Different Shades 18 Fabrication, Providing And Fitting Ofmodularmotor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories As Under:A ) Busbar Chamber:The Busbar Chamber Shall Be Fitted At The Top Of The Panel Horizontally Throughout The Length. There Shall Be 3 Nos. Of Phase Bus Bar And 1 No Neutral Bus Bar And 1 No Earthing Bus Bar. The Bus Bars Shall Be Air Insulated And Made-Up Of High Conductivity Copper With Current Density Of Suitable Rating For 100 Ampere. All Panel Compartments Shall Be Provided With Suitable Cable Alley And Vertical Bus Bar Alley. Suitable Segregation Shall Be Provided In Between Busbar Chamber And Adjoining Compartments. The Bus Bar Shall Be Pvc Sleeved With Color Strips Of Red, Yellow, Blue And Black And The Same Be Arranged In Accordance With Is-375 Specs. Electrical Clearances Shall Be Maintained Between Phases, Neutral And Body As Per Standards.D ) Motor Back-Up Protection Mccb:Qnty = 2 No’S No. Of Poles = 3Pcurrent Rating= 63 Arated Operational Voltage =415 V +15 %Rated Frequency= 50 + 3% Hz Ambient Temperature = 40C°Ultimate S.C Breaking Cap. At ( 415V Ac, 50 Hz ) = 36 Kae ) Submersible Motor Starter:Fully Automatic Submersible Motor Starters. Rating = 30 Hp Power Specs =3 ?, 415 + 15% V, 50 + 3 % Hz.Relay Range= 30- 50 A.Protection = Under Voltage / Over Voltage Qty = 02 No’Srest Of Spacifications If Any As Per Clause 43 Of Techanical Annexure Of Sbd 19 Providing, Fitting, Testing And Commissioning Of 40 Voltage Stabilizeras Per Specifications Below: Type Of Voltage Controller: Manually Operated Copper Wound, 3-Phase, Ac Power Supply Multi Step.Type Of Regulator: Double Plate Type With Electrolytic Copper Contacts.Input Voltage : 250-400 Volts. ( 3 Phase ) Output Voltage : 400 ±10% Volts.Frequency : 50 ±3 C / S.Windings : Electrolytic Grade Copper Of Adequate Section, Vacuum Impregnated And Oven-Dried.Insulation : Fiber Glass Insulations To Tested Parameters.Cooling: Naturally, Oil Cooled Temp. Rise ( Max ) : 30°C Above Ambientmounting : On Uni-Directional Wheels. Correction Rate : 30 Volts Per Stepwave Form Distortion: Virtually Nilduty Cycle : 100% Continuous.Enclosure : Ms Sheet Enclosure In Pressed Cgr Sheet Powder Coated With Radiators.Core Laminates: High Grade, Low Eddy Loss, Grain Oriented Silicon Steel Laminations.Load: Three Phase Induction Motor Load. Load Amperes ( Continuous ) Overload In 24-Hours Operation: 10% Above Continuous Ampere Rating.The Voltage Stabilizer Shall Have T-Oil Level Indicator Gauge Preferably Glass Type Tube Or Otherwise Visible To Naked Eye. The Top Of The Container To Have A Display Panel For Housing 02 Numbers Digital Voltmeters ( 0-500V ) Along With 4-Way Selector Switch And Set Of Neon Indicators For Incoming And Outgoing Phases ( 06 No’S ) .Insulating Media ( T. Oil ) Of 11 Kva Grade To Be Provided And Filled Up To Top Level, With Dielectric Strength Of 5 Kv At 4M Air Gap. The T-Oil Of Specific Grade Should Be Provided In Separate Barrels And Filled At Site Up To Top Level.The Voltage Stabilizer Shall Be Accepted With Manufacturers Dully Stamped Test Certificate And Shall Have Name Plate With Specifications. 20 Providing And Fitting Of 50 Mm2, 3.5-Core, Xlpe Armoured Aluminium Cable Conforming To Is: 7089 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc.Note:- The Cable Terminal Ends For Connection To Switchgear At Various Requisite Points Shall Be Al. Thimbles Of Dowel’S Make And Of Appropriate Size And Connected By Hydraulic Crimp Tool Only. 21 Providing And Fitting Of 3-Core Flat 16Sq.Mm Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipments . The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. 22 Providing And Fitting Of Single-Core, Copper Pvc Insulated Cable, Conforming To Is: 694 Part 1St For Internal Connectionscrimping, Taping Etc.Note:- The Cable Terminal Ends For Connection To Switchgear At Various Requisite Points Shall Be Al. Thimbles And Of Appropriate Size And Connected By Hydraulic Crimp Tool Only.Single Core Pvc Insulated 16 Sqmm 23 P / I Of Earthing Station For 63 Kva Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards.Safe Earthing Electrode Size:80 Mm Dia , Length:2000 Mmback Fill Compound :30 Kg 24 Creation Of Pope Mounted , Outdoor Type63 Kva Electric Sub Stationby Way Ofs / I / T / C Of 11 / 0.433 Kva , 3 Phase Distribution Transformer With Bimetallic Terminal Connectors Energy Level -2 Aluminum Wound63 Kvaspecifications Conforming To Is : 1180 ( Part 1 ) 2014 With Latest Amendments Type Of Cooling:Onan.The Ht Transformer Is Completely Filled With Suitable Grade Transformer Oil Up To Required Level. The Job Includes Carriage, And All Leads And Lifts Involved.The Ht Transformer Shall Be Of Reputed Make From An Iso Certified Company As Per Relevant Standards And A Test Certificate Shall Be Provided Before Installation. The Transformer Shall Also Be Provided With Breather Fill With Silica Jel Crystals , Conservator With Oil Level Indicator , Explosion Vet And Adequate Radiator Fins / Tubes. The Impedance Of Transformer Shall Be As Per Is:1180 ( Part 1 ) 2014 With Latest Amendments.Note: The Scope Of The Work Shall Include Obtaining Of Necessary Inspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificate 25 Providing And Fittingg.I Channel Flat Of8Sizes Including Clamps 26 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Ofht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Rated Voltage 11Kv 200A Complete As Per Is Specs. 27 Supply, Installation, Testing And Commissioning Of 11Kvpolymer Fuses Sethorn Gap3-Phase 200 Asuitable For Vertical Installation . 28 Supply, Installation, Testing And Commissioning Ofgapless Surgearrestor Station Class, 10Ka, 9Kv, La With Polymer Housing , Station Type . 29 Supply And Fitting Of 11 Kv Polymeric Composite Pin Insulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative , Creepagedistance 320 Mm 30 Supply, Installation, Errection Of9 Mtrs Long St- 410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories .Wherever Required. 31 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement. 32 Earth Work In Excavation By Manual Means In Trenches For Foundation , Drains , Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts , Wells , Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed.All Kinds Of Soil 33 Providing And Laying Of Soling Stone Including Manual Compaction 34 Concrete Cement Bottoming 1:2:4 Mix As Per Rec Standards , 0.5 Cum / Pole 35 P / F Danger Plate With Clamps 36 Providing And Fixing G.I Barbed Wire For Anti Climbing 37 Providing And Fitting Of Galvanized Stay Set With 50 X 8 Mm Stay Clamp , Guy Insulator ( 2No. ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts , 2 N0- Turn Buckle , 1.8 M Long , 16 Mm Diameter Solid G.I Stay Rod & 7 / 3.15 Mm Dia. G.I Stranded Wire Complete. 38 Painting Of Poles Red Oxide 39 Painting Of Poles Aluminum Paint 40 Providing And Fitting Of Acsr As Per Is 398 ( Part-2 ) 1996 For 50 Sq.Mmacsr ( Galvanised Steel Reinforced ) For Fitment Of Various Accessories 41 Supply, Installation And Testing Of 35 Sq Mm Xlpe Aluminum H.Tcable ( Abc Type ) Of 11 Kv Grade With Following Specs.Size ( Cross Sectional Area In Sq Mm ) = 3×35Phases:Red, Yellow, Blue 42 P / F Of 11 Kv Cable Termination Kit For Connecting 35 Sq Mm Xlpe Cable ( Abc Type ) With The Existing Ht Line Near Tapping Point And Ht Transformer. 43 Providing And Fitting Of Lt Distribution Box For 63 Kva H.T Transformer With200 Amp Mccb For Incomer And 100 Amp Sfu For Out Going Circuits . 44 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter ( Make: Microtek / Luminous ) Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover. ( Make: Amaron / Exide ) With 2-Core 6Mm2 Cu Wiring As Per Site Requirement Along With Other Accessories Like Ss-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 45 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: -Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide.The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 46 Tool Kit For Maintenance: -The Tool Kit For Maintenance Shall Comprise Of The Following And All The Items As Mentioned Below Shall Be Of :Rest Of Spacifications If Any As Per Clause 57 Of Techanical Annexure Of Sbd 47 Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -Rest Of Spacifications If Any As Per Clause 58 Of Techanical Annexure Of Sbd 48 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply. 49 Providing Of 1 Kw Heat Convector For Operators For Winter Season. 50 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site.Size: 4’×6’ Out Ms Angle Of 40X 40X 5Of 36 Rft And Ms Sheet Of 1 Mmthicktotal Weight Of50.16 Kgs

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 07-11-2022 Extension Notice II Date 09-11-2022
2 27-10-2022 Extension Notice Date 05-11-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 59560.0 /-
Tender Value
INR 29.78 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail