| 1 | Creation of 11/0.433kV, 400KVA, 3-phase Distribution Substation atSouth Ext. Trikuta Nagar, Jammu |
| 2 | Supply, Installation & commissioning of 11/0.433 KV, 400 KVA 3-Phase Distribution Transformer with Bi-metallic terminal Connectors, Energy Level: 2, \"BIS Marked\" (Copper Wound) alongwith LV Cable Box having detachable Alumnium Gland plate including Transportation |
| 3 | Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface. |
| 4 | Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 5 | Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 6 | Supply, Installation, Testing & Commissioning of 11 kV Horn GapFuse Set 3 Phase 200A |
| 7 | Providing & Fixing of Single PhasePVC Cable 400 mm² ,1.1K V Grade, PVC Insulated StrandedUn-Armoured FRLS type alongwithAl. Thimbles for 400 mm² Cable termination with four coloredPVC Tapings to distinguish the LT Phases and the Neutral. (2 Ckt) |
| 8 | 11kV Polymeric composite Disc Insulator 12kV with fitting, min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 9 | Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc. |
| 10 | Providing of Earthing of substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 11 | Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 12 | Providing & Fixing of Pole mounted LT Distribution Box for 400 KVA DTR with 2 No. Triple PoleMCCB of 400 Amp with adjustable overload release of (80-100%)forincomer && switch fuse unit for Out Going 2No Ckts. includingBusbar arrangementsfor Phases & Neutralof EC Grade Aluminium,PVC Insulated Sleeved Busbar of required load handling capacity with colour code for Phases and Neutral differentiation, includingAluminium thimbles of required sizes for proper termination etc. |
| 13 | Construction of Cement Platform (8x8x3) & 3feet below ground level ) for 400 KVA SubStation along with the mesh fencing around the Periphery. (complete Job) |
| 14 | Providing & Fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 15 | Providing & Fixing of Wedge Connectors / PG Clamps |
| 16 | Providing & Fixing of Danger Plates with Clamps |
| 17 | Providing & Fixing of Anti Climbing device with Clamps |
| 18 | Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole |
| 19 | Laying of 0.600 Km LT line on 8Mtr PCC poles using ACSR Rabbit Conductor at South Ext. Trikuta Nagar, Jammu |
| 20 | Supply, Transportation, Erection of 8 Mtr Long PCC Pole (WL-200 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 21 | Providing & Fixing of MS U-Clamp duly painted with two coats od Red Oxide and Al Paint with Shackle Insulator (Porcelain) along with Nut & Bolt of sorts |
| 22 | Supply, Laying & Stringing of ACSR Rabbit Conductor through insulators including proper binding & twisting with soft Aluminium Wire |
| 23 | Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete |
| 24 | Providing & Fixing of Danger Plates with Clamps |
| 25 | Providing & Fixing of Anti Climbing device with Clamps |
| 26 | Providing & Fixing of LT Line Spacers |
| 27 | Providing of Earthing Complete by GICoil ----Nominal diameter of the G.I Wire 4mm, No. of closely bound turns 115, External Dia of the coil 50mm, Length of Coil 460mm, Free length of GI Wire at one end ofcoil 2500mm, Total Weight of Coil 1.850Kg. |
| 28 | Providing of Stone Pad 300 mmx300mmx75mm |
| 29 | Providing and fixing of Aluminium sleeves |