| 1 | Creation of 11/0.433kV, 250KVA , 3-phase Distribution Substation |
| 2 | Supply, Installation & commissioning of 11/0.433 KV, 250 KVA 3-Phase Distribution Transformer with Bi-metallic terminal Connectors, Energy Level: 2, \"BIS Marked\" (Copper Wound) alongwith LV Cable Box having detachable Alumnium Gland plate including Transportation |
| 3 | Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface. |
| 4 | Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 5 | Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 6 | Supply, Installation, Testing & Commissioning of 11 kV Horn GapFuse Set 3 Phase 200A |
| 7 | Providing & Fixing of Single PhasePVC Cable 240 mm² ,1.1K V Grade, PVC Insulated StrandedUn-Armoured FRLS type alongwithAl. Thimbles for 240 mm² Cable termination with four coloredPVC Tapings to distinguish the LT Phases and the Neutral. (2 Ckt) |
| 8 | 11kV Polymeric composite Disc Insulator 12kV with Fitting, min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 9 | Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc. |
| 10 | Providing of Earthing of substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 11 | Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 12 | Providing & Fixing of Pole mounted LT Distribution Box for 250 KVA DTR with 2 No. Triple PoleMCCB of 300 Amp with adjustable overload release of (80-100%)forincomer && switch fuse unit for Out Going 2No Ckts. includingBusbar arrangementsfor Phases & Neutralof EC Grade Aluminium,PVC Insulated Sleeved Busbar of required load handling capacity with colour code for Phases and Neutral differentiation, includingAluminium thimbles of required sizes for proper termination etc. |
| 13 | Providing & Fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 14 | Providing & Fixing of Wedge Connectors / PG Clamps |
| 15 | Providing & Fixing of Danger Plates with Clamps |
| 16 | Providing & Fixing of Anti Climbing device with Clamps |
| 17 | Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole |
| 18 | Thickening of Existing HT line with ACSR Rabbit Conductor and insertion of poles in longer Spans |
| 19 | Erection, Testing & Commissioning of 9 Mtr Long PCC Pole (WL-300Kg) including Transportationto erection site, excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 20 | Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc. |
| 21 | Laying & Stringing of ACSR RabbitConductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire |
| 22 | Providing & Fixing of PG Clamps for 50mm² ACSR Conductor |
| 23 | Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 24 | Providing & Fixing of 11kV Polymeric composite Disc Insulator with fitting12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 25 | Providing & Fixing of Galvanized Nuts and Bolts |
| 26 | Providing & Fixing of Danger Plates with Clamps |
| 27 | Providing & Fixing of Anti-Climbing Device with Clamps |
| 28 | Providingof Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 29 | Providing & Fixing of Stone Pad (300 mm x 300 mmx 75 mm) |
| 30 | Providing & Fixing of Aluminium Jointing Sleeves |
| 31 | Providing & installationof Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |