Tender For Survey, Supply Of Material / Equipment, Erection, Testing And Commissioningforsop To Proposed Himuda Colony At Narghota By Prov. 2X250kva Transformers, Aug Of 25Kva To 63Kva Narghota, Strenghtening Of Ht Line & New Ht Line Uesd No. I Dharamshala. ( Seop-39 / 2022-23 ) . -Acsr 6 / 1 / 3.35 Mm 2 St Pole 11 Mtr. Long W / L 200 Kg 3 Rcc Muff Of 2000 Mm Length 4 Run Thro Str ( Delta Formation ) 5 X-Arm: [ Ci ( 100X50x6mm ) , L:1270 Mm I / C Tolerance Of 100 Mm Either Side ) 6 Ai ( 50X50x6 Mm ) , L-750Mm X 2 Nos. 7 Pole Top Bracket ( Msci:100X50x6mm-100Mm ) 8 11 Kv Pin Insulator 9 Dead End Structure 10 Belt Set-Ms Ai:50X50x6 Mm, L-1800 Mmx 2 Nos 11 X-Bracing Set-Ms Ai:50X50x6, L-2125 Mmx 2 Nos 12 X Arm ( Horizontal ) -Ms Ci:10X50x6, L-2340 Mmx 2 Nos.Delta Formation 13 Disc Insulator Set Polymeric Bs, 90Kn ( Cleaves And Tong ) 14 Ht Stay / Guy Arrangement 15 Stay Set Complete In All Respect 16 Stay Wire ( 7 / 3.15 Mm ) 17 Earthing 18 Ht Earthing Set Complete 19 Single Continous Earth Wire ( Gi, 8Swg ) Alongwith 2 Wire Length For Avg One Road Crossing @20 M And Additionl 1% ( Sag & Wastge ) @0.102 Kg / M 20 Eye Hook For Earth Wire 21 Earth Wire Clamp 22 Ms Ci :75X40x6, L-2400 Mm For Road Crossing 23 Half Clamp [ On Double Pole Dead End Str:4 Nos, On Run Through Str:02 Nos. ] 24 Full Clamp [ On Double Pole Dead End Str:4 Nos, On Run Through Str:02 Nos. ] 25 Danger Plate 26 Nut & Bolt Of Various Size ( Galvenised / Coated ) With Flat And Spring Washer ) 27 11Kv Rmu Having 630 A 1 Cb+1Lbs, 2 Nos Lbs 28 Plinth & Fencing Of 11Kv Rmu 29 11Kv Ht Cable 185Sqmm Xlpe Armoured 30 Termination Kit For Ht Cable 11Kv Ht Cable 185Sqmm 31 Barbed Wire 32 Aluminium Paint 33 11 Kv Go Switch 34 D O Fuse Unit 35 Erection Charges Of 11Kv Line Cd21-22 36 Erection Charges Forrmu Cable 185 And Kit 37 Transportation Charges 38 2X250kva Transformer 39 Distribution Transformer ( Ordinary ) , 11 / 0.4 Kv, 250 Kva Cu Wound ( I / D ) 40 Steel Tubular Poles 9 Mtr., ( Working Load > 200 Kgf / M² ) 41 Muffs With Concerete Filling 42 X-Arm: [ Channel Iron ( 100X50x6 Mm ) , Length : 2800 Mm X 2 Nos ] For Incomer Line 43 Ms Angle Iron ( 50X50x6 Mm ) , Length: ( 2800 Mm ) X1 Nos For LaS 44 X-Arm: [ Channel Iron ( 75X40x6 Mm ) , Length : ( 2800 Mm X 4 Nos ] For Supporting Do Fuse Unit & Go Switch 45 Transformer Bed, Belting & Knee Bracing 46 X-Arm: [ Channel Iron ( 100X50x6 Mm ) , Length : 2800 Mm X 2 Nos ] For Transformer Bed 47 X-Arm [ Channel Iron ( 100X50x6 Mm ) , Length : ( 460Mm ) X 2 Nos For Supporting Main Channel Of Transformer ] 48 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 2800 Mm ) X 2 Nos 49 Ms Angle Iron ( 35X35x5 Mm ) , Length : ( 460 ) X 2 Nos 50 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 950 Mm ) X 2 Nos For Bed Knee Bracing 51 Transformer Lt Distribution Box And Go Switch Fixing Assembly 52 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 2800 Mm ) X 2 Nos 53 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 450 Mm ) X 1 Nos 54 Go Switch Handle Supporting: [ Channel Iron ( 75X40x6 Mm ) , Length : 460 Mm 55 Go Ab Switch Unit ( 11Kv, 400A, 25 Ka ) Tripple Pole O / D Type 56 D.O Fuse Unit 57 Surge Arrester, 9 Kv Station Class ( Porcelain Type ) 58 Discs Insulator Sets ( Comprising 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) Including Dead End Clamps Etc. ) 59 Stay Set Complete 60 Stay Wire ( 7 / 3.15 Mm ) ( 7.0 Kg Per Stay Set ) 61 Pipe Earthing Set 62 Lt Distribution Panel Box With Acb ( 630A, 50Ka, 4P, 1No ) & Sfu ( 100A, 6No, Rewirable ) 63 Half Clamp ( M.S. Flat 50X6 Mm ) 64 Full Clamps ( M.S. Flat 50X6 Mm ) 65 Nuts And Bolts Of Various Sizes ( Galvanised / Coated ) [ Preferably 16 Mm F Or More ( With Flat And Spring Washers ) ] 66 Aluminium Thimble 67 Aluminium Thimble 68 Danger Plate 69 Barbed Wire 70 Lt Cable ( 3.5 Core ) 400 Mm² 71 Aluminium Paint. 72 Aaac 7 / 3.15 For Earthing 73 Prov Plinth As Per Hprc 74 Prov Chain Link Fencing 75 Control Cable 12 Core 2.5 Sqmm Copper Cable 76 Energy Meter Dtr3-?, 3 / 4 Wire Ct Operated Static Tri-Vector Meter. 400 / 5A ( Hpsebl M&T Tested ) 77 Augmentation Of 25Kva To 63 Kva 78 63 Kva, 11 / 0.4 Kv, Distribution Transformer ( Ordinary ) 79 Pipe Earthing Set 80 Lt Distribution Panel Box With Mccb ( 160A, 25 Ka, 4P ) And Sfu ( 32 A, 4 No. Rewirable ) 81 Errectioncharges For Sub Station 82 Erection Charges For 25 To 63 Kva & Dismentaling Ofdtr 83 Transportation Charges 84 Quantities Are Mentioned Above Are Tentative And Actual Quantity Shall Be Worked Out After Check Survey To Be Carried Out By The Successful Tender And Detailed Engineering And Finalization Of Tower Location Chart.Payment Shall Be Made As Per Approved Bill Of Material / Actual Quantities Measured At Site.