}

Electro-Mechanical And Civil Works To Be Carried Out At Bohripora Sheeraz Colony ( Stage 1St And Stage 2Nd ) Electro-Mechanical And Civil Works-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make With, Baramulla-Jammu And Kashmir

Government Departments has published Electro-Mechanical And Civil Works To Be Carried Out At Bohripora Sheeraz Colony ( Stage 1St And Stage 2Nd ) Electro-Mechanical And Civil Works-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make With. Submission Date for this Tender is 24-10-2022. Spare Part Tenders in Baramulla Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

34092709
Corrigendum : Electro-Mechanical And Civil Works To Be Carried Out At Bohripora Sheeraz Colony ( Stage 1St And Stage 2Nd ) Electro-Mechanical And Civil Works-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make With
Open Tender
Indian
Jammu And Kashmir
Baramulla
24-10-2022

Tender Details

Electro-Mechanical And Civil Works To Be Carried Out At Bohripora Sheeraz Colony ( Stage 1St And Stage 2Nd ) Electro-Mechanical And Civil Works-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowing Specifications: At Stage 1St Discharge Of The Pump = 21000 Gph Dynamic Head = 21 M Speed = 1450 Rpmworking Voltage = 380 ± 15 V, 03 Phaserating = Corresponding To The Head And Discharge Not Less Than 25 Hp.Rest Of Specification / Details Are As Per Clause 6 Of Annexure C Of Sbd 3 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) For Y Junction And Washoutsize: 150Class:C ( Heavy ) Rest Of Specification As Per Clause 8 Of Annexure C Of Sbd 4 Cutting Of Hot Dip Galvanized Gi , C-Class Pipe Acoss The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Includes Providing And Welding Of M.S. Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17Dia: 150`Rest Of Specification As Per Clause 11 Of Annexure C Of Sbd 5 Fabrication , Providing And Fiting Of Y- Junction Havingminimum 1M Arm Length Of Each Arm To Be Fabricated Out Of G.I C Class Pipe With M.S. Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends.Dia: 150 Mmrest Of Specification As Per Clause 8 Of Annexure C Of Sbd 6 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seatedglandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .Size: Dn150pn:1.6 / 16 Rest Of Specification / Details Areas Per Clause 12 Of Annexure C Of Sbd 7 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size: 150Mmpn: 1.6 / 16Rest Of Specification / Details Areas Per Clause 13 Of Annexure C Of Sbd 8 Providing And Fitting Of 150 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 9 Providing And Fitting Of Flanged Washout Tee 150 Mm , Including Nuts, Bolts And Gasket As Per Site Requirement.Rest Of Specification / Details Areas Per Clause 09 Of Annexure C Of Sbd 10 Providing & Fitting Of35 Sq Mm Single Core Copper Conductor ( Flexible ) Pvc Insulated Heavy Duty Industrial Cables ( Unsheathed ) , 1100 Volts Conforming To Is: 694- For Connecting Motors From Panel , Stabilizers In Rubber Conduit . Job Includes Providing& Laying Of Flexible Conduit For Cu Cable With Lugs As Per Requirement Heat Shrinkable Outdoor Cable Termination Kitrest Details As Per Clause 73 Of Annexure C Of Sbd 11 Providing, Installation , Testing Of Power Service Cablefor Workingvoltage Up To And Including 1100 Volts;95 Sq Mm Armored Aluminum 3.5 Core Cable As Service Line From Output Terminals Of Ht / Lt Transformerto Cubical Panel. Cost Includes Laying Of Cable In Trenches In Pvc Conduit Where Ever Itis To Be Laid Underground As Per Site Requirement Included Is Termination Of Ends With Suitable Aluminum Tube Terminals Dully Crimpled & Taped. Rest Specifications As Per Clause 68 Of Annexure C Of Sbd 12 Providing And Fitting Of 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. The Main Specification Of The Cable Is Given Below:Size: 16 Sq Mmrest Specification As Per Cluase 47Of Annexure C Of Sbd. 13 Providing , Fitting, Testing And Commission Of Heavy Duty De-Silting Pumping Unit Complete Unit Of Capacity 25000 Gph Head 25 M And Motor Including Compete Cabling- 2 Units , Starter- 2Nos ( One As Standby ) , Sluice Valves , Agitator Function, Delivery Pipe Minimum 50 M With Ms Supports With All Joints And Accessories For Both Units. Complete Jobjob Includes Fabrication , Providing , Fitting And Testing Of Gantry System For Fabricated Out Of Iscm / Ismbbelow Machine Floor Of Circular Shape Approx. 7 M Dia.The Gantry System Should Be Fabricate In Such A Way That Desilting Pumping Unit Should Move In All Directions. Job Includes Providing And Fitting Of 2 Mt Chain Pulley Block ( Chain Lift 10 M ) And Monorail Of Induff / Globe Make. The De-Silting Pumping Have. . Job Also Includes Making Of Hole And Covering Of The Same With 8 Mm Thick Ms Sheet & Isa.Job Also Includes Fabrication Of Ladder And Plate Form At Middle Of Sump In Isa, Ismc For Handling Of The System 14 Design, Fabrication, Successful Launching Of Boat, Fabricated Out Of Structural Steel Of Different Cross Sections To Be Used In Flash Floods And Drawdown Of Water Level And Capable Of Carrying At Least Eight Persons Of An Average Load Of 70 Kgs. Per Person And Two Numbers 20 Hp, 20000 Gallons Capacity Open Well Submersible Non Clog Pumping Units.? The Size Of The Boat Shall Not Be Less Than 2.4M X 3.9M.? Suitable Number, Size, Air Tight Leak Proof Plastic Floating Bodies Shall Be Firmly, Suitably Arranged Under The Structure.? Two Openings Of Approximate Size 600Mmx900mm Shall Be Kept At Suitable Places On The Floor Of The Boat For Installation / Accommodating Horizontal / Submersible Pumping Units. A Separate Detachable Suitable Arrangement Is To Be Provided For Resting The Pumping Unit Under The Water Surface With A Minimum Submergence Of 600Mm? Trash Guard Arrangement Is To Be Provided To Restrict Entry Of Trash Into The Pumping Unit Cabin.? Two Suitable, Gantry Mechanism, With Adjustable Height, Shall Be Fixed With The Boat Over Both The Openings Kept For The Pumping Units.? The Job Also Includes Providing, Fitting And Testing Of At Least One 02-Ton Capacity Chain Pulley Block For Easy Assembling And Dismantling Of The Pumping Units To / From The System.? The Boat Shall Also Be Provided With Spikes Having Length Of Not Less Than 6000Mm Positioned At All The Four Corners In Order To Restrict The Movement Of The Boat Whenever Necessary Maintenance Work Needs To Be Performed On The Boat.? Necessary Arrangement Is To Be Provided To Tie The Boat With The Help Of Steel Rope At The Bank Of The River ( Steel Rope Of Suitable Diameter And Length As Required At Site Is To Be Provided By The Firm ) ? Necessary Ladder Arrangement Is To Be Provided For Easy And Safe Access Of Men And Machinery To The Boat.? The Surface Area Of The Boat Is To Be Covered On All Sides With The Help Of At Least 600Mm High Vertical Steel Bars With A Common Horizontal Steel Rail At The Top For Safe Movement Of The Maintenance Staff. ? The Whole Structure Shall Be Coated Twice With Red Oxide Primer Followed By Two Coats Of Yellow / Blue Colour.? Providing And Fitting Of 15 Meters Long 80Mm Diameter Pvc Flexible Pipe Capable Of Withholding A Pressure Of Not Less Than 4.5 Kg / Cm2.The Pipe Is To Be Connected To The Delivery End Of The Pump And Rising Main Of The Scheme With Special Joint Arrangement To Ensure Leak Proof Fitting.? The Top Surface Of The Boat Shall Preferably Be Covered With Steel Bars Of Suitable Section Maintaining A Suitable Gap Between The Bars.Before Fabrication The Interested Agency Shall Furnish Necessary Drawings Of The Whole Structure. 15 Supply, Installation, Testing & Commissioning Of Submersible Pumping Unit ( Open Well Nog-Clog Type ) As Per Following Specifications: Pump:• Discharge : 21000 Gph• Head : 45 Meters• Speed : 2900 Rpmp• Type Of Pump: Submersible Unclog, Solid Handling Pump• Delivery Outlet: 80 -100 Mm ( As Per Design ) • Quality Of Water To Be Handled : Raw Water / Silt Material Of Construction:• Pump Casing: Cast Iron• Impeller : S.S / Bronze• Pump Shaft:Stainless Steel / Chrome Steel / Bronze• Pump Shaft :Stain Less Steel• Wear Plate :Cast Iron• O-Rings: Nitrile Rubber• Motor Body : Cast Iron• Motor:• Type : Squirrel Cage 3-Phaseinduction Motor• Speed : 2900 Rpm •Rating: Suitable For Above Parameters• Method Of Starting:Star – Delta. • Frequency:50Hz + 3%• Voltage:415 + 6 %, - 15% • Class Of Insulation:Suitable For Above Rating.The Motor Shall Be Made Of Corrosion Resisting Materials To Resist Corrosion Under Normal Conditions And Shall Have A Name Plate Giving Requisite / Necessary Information.The Pumping Unit Shall Be Provided With Test Certificate And Required Size Nipple / Tail Piece 2 Feet Long Out Of G.I Pipe D, Nuts, Bolts, R.I Cloth Etc.As Per The Site Requirement 16 Providing , Installation , Testing And Commissioning Of Mu-G40 Factory Fabricated Pump Control Panel / Switch Gear Protection Equipment Submersible Pumping Unit Suitable Having Automatic Star Delta Starter Contractor Type With Relay Range ( 36-60 ) A And Should Provide Protections ( Like Single Phasing , Reversing , Over Voltage , Under Voltage , Under Current ) , Indicationg Lamps , Push Buttons For On & Off , Metering Module With Selector Switch Suitable For 415Volts 50 Hz 3 Phase Ac Supply Including Necessary Interconnections Etc As Required . Make Reputed Make. The Job Includes Fab, P / F Of Suitable Angle Supports As Per Site Requirement . The Job Also Includes P / F Of 100 A 3 Polemccbheavy Duty- 01 No With Breaking Capacity Of 36 Ka. Job Includesfitment Of The Mccb On Wall In An Enclosure Provided By The Firm At Site 17 Connecting New System To Existingrising Main By Way Of:A ) Providing And Fitting Of Heavy Duty 100 Mmtabular Flanged Tee-01 N0b ) Providing And Fitting Of 100 Mm Dia Di Flanged Sluice Valves-02 No’Sc ) Providing And Fitting Of 100Mm Dia Di Flanged Nrv-01 Nod ) Providing , Laying And Fitting Of Heavy Duty 100 Mm Diaflexible Hose Pipe Duly Gi Flanged- 50 Mf ) Providing Fitting Of Tail Piece At The Delivery Of The Pump As Per Site Requirement Along With Flanged Bends- 01 C Jobthe Job Includes Providing And Fitting Of Ri Cloth, Nuts And Bolts As Per Site Requirement. All Tools And Tackles Required At Site Is To Be Provided By The Firm 18 Providing, Installation, Testing And Commissioning Of 100 Kva Voltage Stabilizer Rest Details & Specification As Per Clause 44 Of Annexure C Of Sbd 19 Fabrication Providing And Fitting Of 3 Phase Modular Control Panel. The Technical Details / Ratings Of Various Components Of Modular Control Panel Are Given Below B. Main Circuit Breaker = 200 Ac. Changeover Switch = 200 Ad. Motor Breakup Protectionmccb= 160 Ae. Fasdstarter - 2 Units With Rating Line Contactor _Ac3 70 A , Delta Contactor- Ac3 70 Astar Contractor- Ac3 50 Atimer- Star Delta Electronicthermal Overload Relay- With Relay Range 35-70 Direct / Ct Operated Suitable-Rangeaux Coil Voltage Wide Band Fitted With Seperate Stabilization Unit Min 1Kw Aux Wiringf ) . Auxillary Mccb =63 Ampwith S.C. Breaking Capacity Of36kag ) . Motor Protection Relay Suitablei ) M-Power Module For Mobile Starter & Earth Fault Relay J ) Water Level Controller Rest Of Deatils / Technical Specification Are As Per Clause 43 Ofannexure C Of Sbd 20 Providing, Installation And Testing Ofheavy Duty Manual Type Triple Spur Gear Chainpulley Block Along With Monorail Geared Travelling Trolley Having Followingfeaturesmake = Reputed Make Capacity = 3 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 Mrest Details / Specification As Per Clause 24 Of Annexure C Of Sbd 21 Providing, Installation And Testing Ofheavy Duty Manual Type Triple Spur Gear Chainpulley Block Along With Monorail Geared Travelling Trolley Having Followingfeaturesmake = Reputed Make Capacity = 2 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 Mrest Details / Specification As Per Clause 24 Of Annexure C Of Sbd 22 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole Rest Of Deatils / Technical Specification Are As Per Clause 50 Ofannexure C Of Sbd 23 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole , Including Mcb Fiited In Box 10Arest Details / Specification As Per Clause 51 Of Annexure C Of Sbd 24 Providing And Installation Of Junction Box With Dp 32Amp Mcb To Serve As Amin Switch For Led Lighting Including Complete Wiring Min 20-30 M From Panel Board.Rest Details / Specification As Per Clause 52 Of Annexure C Of Sbd 25 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer , Including Wiringrest Details / Specification As Per Clause 53 Of Annexure C Of Sbd 26 Providing & Fitting Oflighting Points For ( Machine Room , Operators Room, ) As Per Site Requirement In 1.5 Mm² Multistranded Single Core 1100 Volts, Pvc Insulatedcopper Conductor Through Pvcconduit Pipe By Way, Switches, Socket Modules , Regulators , Indicators, 08 / 10 Watt Led Lamps Surface Light Make. .Included Is Cost On Account Of Modular Switch Boards With The Wooden Frames As Per Site Requirements 27 Providing Fitting Of Heating Points In 2.5Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit By Way Of P / F Of 15 Amp Switches, 6 Pin Socketon Modularfittingas Per Site Requirements. Heating Points Are To Be Connected From Main Control Panel. All Accessories Required Is To Be Provided By The Firm 28 Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. Make Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. 29 Providing, Fitting Of Distribution Board Of Reputed Make 4 Way S P N Single Door Powder Coated Sheet Steel Enclosure For Surface Mounting Fitted With Bus Bar, Din Channel, Neutral Link And Incoming Contact. The Above Db Is To Be Provided / Fitted With Double Pole 40 Amp Mcb For Main. 32 A For Heating Circuit & Rest 3 Of 16 / 6 Amps Each For Premises Luminary, Auxiliary Circuit Of Reputed Make. Further Job Includes Providing / Fitting 4 Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit As Service Line From Main Panel As Per Site Requirements. Connections Should Be Made In Such A Way Lighting Pointsis To Be Connected Via Automatic Transformer By Way Of P / F Switch Socket Arrangement With Allied Fixtures & And Heating Points To Main Panel. Job Includes Dismantling Of Existing Damaged Conduit , Wires, Conduit And Cleaning The Surface Properly 30 Earthing Of Panel Boad, Stabilizer, Motors, Heating Points, Lighting Points, D.G Setsrest Details As Per Clause 48 Of Annexure C Of Sbd 31 Painting On Steel Structure / Pipe With Synthetic Enamel Paint Of Approved Brand And Maufacturer Of Required Colour To Give An Even Shade On New Work ( Two Or More Coats ) Including A Coat Of Approved Steel Primer But Excluding A Coat Of Mordant Solution. ( Ref 13.61 ) Schedule2021 32 Providing , Installation, Testing And Commissioning Of 415+-10 V ( Out Put ) , 3 Phase Dg Set Of Specification Of Approved Make As Per Latest Guide Linecapacity =125 Kvarest Details / Specifications Are As Per Clause 66 Of Annexure C Of Sbd 33 Providing, Installation , Testing Of Power Service Cablefor Workingvoltage Up To And Including 1100 Volts; 95 Sq Mm Armored Aluminum 3.5 Core Cable As Service Line From Output Terminals Of Ht / Lt Transformerto Cubical Panel. Cost Includes Laying Of Cable In Trenches In Pvc Conduit Where Ever Itis To Be Laid Underground As Per Site Requirement Included Is Termination Of Ends With Suitable Aluminum Tube Terminals Dully Crimpled & Taped. Rest Specifications As Per Clause 67 Of Annexure C Of Sbd 34 Providing, Installation , Testing Of Power Service Cablefor Workingvoltage Up To And Including 1100 Volts; 50 Sq Mm Armored Aluminum 3.5 Core Cable As Service Line From Output Terminals Of Ht / Lt Transformerto Cubical Panel. Cost Includes Laying Of Cable In Trenches In Pvc Conduit Where Ever Itis To Be Laid Underground As Per Site Requirement Included Is Termination Of Ends With Suitable Aluminum Tube Terminals Dully Crimpled & Taped. Rest Specifications As Per Clause 67 Of Annexure C Of Sbd 35 Fabrication, Providing, Fitting Of Base Framefor Pumping Units , Covering Of Holes , Fabrication Of Gantry, Ladder , Dg Set Covering, Ht / Lt Transformer Bed With Gantry Fabricated Out Of Ismc / Ismb / Isa / Bars / Ms Pipe / Ms Plain-Chequrred Sheets. Including Making Of Holes In Concrete, Including Metal Primer 1 Coat And Two Coats Of Approved Shade . The Works Is To Be Executed As Per Site Requirement And As Per Dimentions Of Pumping Unit And As Per Directions Of Site Engineer.Rest Of Specification / Details Are As Per Clause 21 Of Annexure C Of Sbd 36 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level 1:2:4 With Stone Aggregrate 20 Mm Nominal Size. For Dg Set Foundatioin / Concrete Beds For Rising-Main As Per Requirement 37 Centering And Shuttering Including Strutting, Propping Etc And Removal Of Form Work For Foundation, Footing , Base 38 Earth Work In Excavation By Manualmeans In Trenches For Foundations, Drains , Pipes , Cables Etc ( Not Exceeding 1.5 M In Width ) Andramming Of Bottoms Lift 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Exacavated Earth As Directed ( All Kinds Of Soil ) ( 2.81 Schedule ) 39 Providing And Laying Of Soling Stone 40 Cement Plaster In Find Sand In 1:3 Mix Finished With A Coat Of Neat Cement And Curing Complete 18 Mm Thick. ( S-11.8 ) 41 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter With 12V, 180Ah Tubular Inverter Batteryrest Details / Specification As Per Clause 54 Of Annexure C Of Sbd 42 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen . Rest Details / Specification As Per Clause 55Of Annexure C Of Sbd 43 Tool Kit For Maintenance: -The Tool Kit For Maintenance As Per Detailed Specification In Clause 56 Of Annexure C Of Sbd 44 Providing Of Good Quality Conveinence And Utility Items As Per Details In Clause57 Of Annexure C Of Sbd 45 Fabricationof6’ X 6’ Angle Iron Bedfor Operators. Rest Details / Specification As Per Clause 58 Of Annexure C Of Sbd 46 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 Nos. Rest Details / Specification As Per Clause 59 Of Annexure C Of Sbd 47 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply.Rest Details / Specification As Per Clause 60 Of Annexure C Of Sbd 48 Providing Of Bamboo Ladder 18 Feet Long With 15 Feet Long Link Rods And Ht Gloves Pair ( 01 Each ) Rest Details / Specification As Per Clause 61 Of Annexure C Of Sbd 49 Providing Of 1 Kw Heat Convector For Operators For Winter Season.Rest Details / Specification As Per Clause 62 Of Annexure C Of Sbd 50 Providing And Fitting Of 01 No. Led ( Scroll Type ) Sign Board Fabricated Out Of Stainless Steel And Metalrest Of Deatils / Technical Specification Are As Per Clause 63 Of Annexure C Of Sbd 51 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site. The Legs Are To Be Grouted In Cement Concrete.Rest Of Deatils / Technical Specification Are As Per Clause 64 Of Annexure C Of Sbd 52 Providing Corrugated G.S Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks , Bolts And Nuts For Dg Set And Overhead Gantryrest Of Deatils / Technical Specification Are As Per Clause 68 Of Annexure C Of Sbd 53 Stage 2Nd A 54 Providing, Fitting, Installation, Testing And Commissioning Of Hz Pumping Unit Of Approved Make Withfollowing Specifications: At Stage 2Nddischarge Of The Pump = 10000 Gph Dynamic Head = 33 M , With Head Range 25-50Speed = 1450 Rpmworking Voltage = 380 ± 15 V, 03 Phaserating = Corresponding To The Head And Discharge Not Less Than 20 Hp.Rest Of Specification / Details Are As Per Clause 5 Of Annexure C Of Sbd 55 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) For Y Junction And Washoutsize: 100Class:C ( Heavy ) Rest Of Specification As Per Clause 8 Of Annexure C Of Sbd 56 Cutting Of Hot Dip Galvanized Gi , C-Class Pipe Acoss The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Includes Providing And Welding Of M.S. Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17Dia: 100`Rest Of Specification As Per Clause 11 Of Annexure C Of Sbd 57 Fabrication , Providing And Fiting Of Y- Junction Havingminimum 1M Arm Length Of Each Arm To Be Fabricated Out Of G.I C Class Pipe With M.S. Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends.Dia: 100 Mmrest Of Specification As Per Clause 8 Of Annexure C Of Sbd 58 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seatedglandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .Size: Dn100pn:1.6 / 16 Rest Of Specification / Details Areas Per Clause 12 Of Annexure C Of Sbd 59 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size: 100Mmpn: 1.6 / 16Rest Of Specification / Details Areas Per Clause 13 Of Annexure C Of Sbd 60 Providing And Fitting Of 100 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 61 Providing And Fitting Of Flanged Washout Tee 100 Mm , Including Nuts, Bolts And Gasket As Per Site Requirement.Rest Of Specification / Details Areas Per Clause 09 Of Annexure C Of Sbd 62 Providing And Fitting Of 100 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 63 Providing And Fitting Of Flanged Washout Tee 100 Mm , Including Nuts, Bolts And Gasket As Per Site Requirement.Rest Of Specification / Details Areas Per Clause 09 Of Annexure C Of Sbd 64 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) For Y Junction And Washoutsize: 80Class:C ( Heavy ) Rest Of Specification As Per Clause 8 Of Annexure C Of Sbd 65 Cutting Of Hot Dip Galvanized Gi , C-Class Pipe Acoss The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Includes Providing And Welding Of M.S. Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17Dia: 80`Rest Of Specification As Per Clause 11 Of Annexure C Of Sbd 66 Providing And Fitting Of 80 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 67 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size: 80Mmpn: 1.6 / 16Rest Of Specification / Details Areas Per Clause 13 Of Annexure C Of Sbd 68 Supply Installation , Testing And Commissioning Of Level Ii Ht Transfromercapacity: 250 Kvarest Of Specification / Details Areas Per Clause 26 Of Annexure C Of Sbd 69 9 M Long St-410 Sp33 Polerest Details As Per Clause 32 Of Annexure C Of Sbd 70 Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5 Cum / Pole 71 G.I V Cross With Top Bracket Including Clamps Rest Details As Per Clause 32 Of Annexure C Of Sbd 72 11 Kva Polymeric Insulators12 Kv , 5Kn , Lighting Impulse 75 Kv Positive And 80 Kv Negative With Creepage Distance 320Mmrest Details As Per Clause 31 Of Annexure C Of Sbd 73 Galvanized Nuts And Bolts ( 1Kg / Pole ) Rest Details As Per Clause 33 Of Annexure C Of Sbd 74 Danger Plate With Clampsrest Details As Per Clause 34 Of Annexure C Of Sbd 75 Anti Climbing Device With Clampsrest Details As Per Clause 35 Of Annexure C Of Sbd 76 Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20 Mm 2.5 Mtr Long Through Gi Strip 77 Red Oxide Coating Rest Details As Per Clause 37 Of Annexure C Of Sbd 78 Alumunium Paint Coating Rest Details As Per Clause 38 Of Annexure C Of Sbd 79 Stone Pad ( 300Mm X300mm X75mm ) Rest Details As Per Clauseof Annexure C Of Sbd 80 Pg Clamps Fo 50 Sqmm Acsr Conductor 81 Acsr Conductor 50 Sqmmrest Details As Per Clause 39 Of Annexure C Of Sbd 82 Gi Channel / Angle / Flat Of Sizes Including Clamps 83 11 Kva Go , Ab Switch 3 Phase, 3 Pole, 200 A, Vertical Typerest Details As Per Clause 28 Of Annexure C Of Sbd 84 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45Kn, Lighting Impulse 75Kv Positive And 80 Kv Negative, Creepage Distance 320Mm 85 Gapless Surge Arrrestor 9Kv, 10 Ka , La With Polymer Housing, Stn Typerest Details As Per Clause 30 Of Annexure C Of Sbd 86 50 Sq Mm ( 2 Ckt ) 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 87 Earthing Of Substation- Rest Details As Per Clause 48 Of Annexure C Of Sbd 88 Lt Distribution Box For 100 Kva Dtr With 4 Pole Mccb For Incomer & SfuS For Outgoing Circuitsrest Details As Per Clause 42 Of Annexure C Of Sbd 89 Galvanised Stay Set With 50X8mm Stay Clam, Guy Insulators ( 2NoS ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts, 2 Nos; Turn-Buckles, 1.8M Long, 16Mm Dia Meter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Completerest Details As Per Clause 36 Of Annexure C Of Sbd 90 Wedge Connectors / Pg Clampsrest Details As Per Clause 36 Of Annexure C Of Sbd 91 Providing, Installation, Testing And Commissioning Of Outdoor Type Ht Trivectometer As Per Iee Rule. Job Includes Grouting Of Legs In Cement Concrete As Per Site Requirement. All Cabling, Earthing And Allied Accessories Required To Be Provided By The Firm. Moreover Firm Responsible For Completing All Sealing Of Pdddepartment And Testing On Load And Noload At Site 92 Sundry Items Like Alumunium Lugs , Jumprs, Binding Tape 93 35 Sq Mm Ab ( Ht ) Cable ( 3X35+1X70 Sqmm ) Xlpe ( 11 Kv , 3C+Earth ) Rest Details As Per Clause 41 Of Annexure C Of Sbd 94 Heat Shrinkable Outdoor Cable Termination Kitrest Details As Per Clause 73 Of Annexure C Of Sbd 95 Providing & Fitting Of25 Sq Mm Single Core Copper Conductor ( Flexible ) Pvc Insulated Heavy Duty Industrial Cables ( Unsheathed ) , 1100 Volts Conforming To Is: 694- For Connecting Motors From Panel , Stabilizers In Rubber Conduit . Job Includes Providing& Laying Of Flexible Conduit For Cu Cable With Lugs As Per Requirement Heat Shrinkable Outdoor Cable Termination Kitrest Details As Per Clause 73 Of Annexure C Of Sbd 96 Providing, Installation , Testing Of Power Service Cablefor Workingvoltage Up To And Including 1100 Volts; 50 Sq Mm Armored Aluminum 3.5 Core Cable As Service Line From Output Terminals Of Ht / Lt Transformerto Cubical Panel. Cost Includes Laying Of Cable In Trenches In Pvc Conduit Where Ever Itis To Be Laid Underground As Per Site Requirement Included Is Termination Of Ends With Suitable Aluminum Tube Terminals Dully Crimpled & Taped. Rest Specifications As Per Clause 68 Of Annexure C Of Sbd 97 Providing, Installation, Testing And Commissioning Of 50 Kva Voltage Stabilizer Rest Details & Specification As Per Clause 44 Of Annexure C Of Sbd 98 Fabrication Providing And Fitting Of 3 Phase Modular Control Panel. The Technical Details / Ratings Of Various Components Of Modular Control Panel Are Given Below B. Main Circuit Breaker = 160 Ac. Changeover Switch = 1600 Ad. Motor Breakup Protectionmccb= 100 Ae. Fasdstarter - 2 Units With Rating Line Contactor _Ac3 50 A , Delta Contactor- Ac3 50 Astar Contractor- Ac3 32Atimer- Star Delta Electronicthermal Overload Relay- With Relay Range 20-50 Direct / Ct Operated Suitable-Rangeaux Coil Voltage Wide Band Fitted With Seperate Stabilization Unit Min 1Kw Aux Wiringf ) . Auxillary Mccb =63 Ampwith S.C. Breaking Capacity Of36kag ) . Motor Protection Relay Suitablei ) M-Power Module For Mobile Starter & Earth Fault Relay J ) Water Level Controller Rest Of Deatils / Technical Specification Are As Per Clause 43 Ofannexure C Of Sbd 99 Providing, Installation And Testing Ofheavy Duty Manual Type Triple Spur Gear Chainpulley Block Along With Monorail Geared Travelling Trolley Having Followingfeaturesmake = Reputed Make Capacity = 3 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 Mrest Details / Specification As Per Clause 24 Of Annexure C Of Sbd 100 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole Rest Of Deatils / Technical Specification Are As Per Clause 50 Ofannexure C Of Sbd 101 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole , Including Mcb Fiited In Box 10Arest Details / Specification As Per Clause 51 Of Annexure C Of Sbd 102 Providing And Installation Of Junction Box With Dp 32Amp Mcb To Serve As Amin Switch For Led Lighting Including Complete Wiring Min 20-30 M From Panel Board.Rest Details / Specification As Per Clause 52 Of Annexure C Of Sbd 103 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer , Including Wiringrest Details / Specification As Per Clause 53 Of Annexure C Of Sbd 104 Providing & Fitting Oflighting Points For ( Machine Room , Operators Room, ) As Per Site Requirement In 1.5 Mm² Multistranded Single Core 1100 Volts, Pvc Insulatedcopper Conductor Through Pvcconduit Pipe By Way, Switches, Socket Modules , Regulators , Indicators, 08 / 10 Watt Led Lamps Surface Light Make. .Included Is Cost On Account Of Modular Switch Boards With The Wooden Frames As Per Site Requirements 105 Providing Fitting Of Heating Points In 2.5Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit By Way Of P / F Of 15 Amp Switches, 6 Pin Socketon Modularfittingas Per Site Requirements. Heating Points Are To Be Connected From Main Control Panel. All Accessories Required Is To Be Provided By The Firm 106 Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. Make Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. 107 Providing, Fitting Of Distribution Board Of Reputed Make 4 Way S P N Single Door Powder Coated Sheet Steel Enclosure For Surface Mounting Fitted With Bus Bar, Din Channel, Neutral Link And Incoming Contact. The Above Db Is To Be Provided / Fitted With Double Pole 40 Amp Mcb For Main. 32 A For Heating Circuit & Rest 3 Of 16 / 6 Amps Each For Premises Luminary, Auxiliary Circuit Of Reputed Make. Further Job Includes Providing / Fitting 4 Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit As Service Line From Main Panel As Per Site Requirements. Connections Should Be Made In Such A Way Lighting Pointsis To Be Connected Via Automatic Transformer By Way Of P / F Switch Socket Arrangement With Allied Fixtures & And Heating Points To Main Panel. Job Includes Dismantling Of Existing Damaged Conduit , Wires, Conduit And Cleaning The Surface Properly 108 Earthing Of Panel Boad, Stabilizer, Motors, Heating Points, Lighting Points, D.G Setsrest Details As Per Clause 48 Of Annexure C Of Sbd 109 Painting On Steel Structure / Pipe With Synthetic Enamel Paint Of Approved Brand And Maufacturer Of Required Colour To Give An Even Shade On New Work ( Two Or More Coats ) Including A Coat Of Approved Steel Primer But Excluding A Coat Of Mordant Solution. ( Ref 13.61 ) Schedule2021 110 Fabrication, Providing, Fitting Of Base Framefor Pumping Units , Covering Of Holes , Fabrication Of Gantry, Ladder , Dg Set Covering, Ht / Lt Transformer Bed With Gantry Fabricated Out Of Ismc / Ismb / Isa / Bars / Ms Pipe / Ms Plain-Chequrred Sheets. Including Making Of Holes In Concrete, Including Metal Primer 1 Coat And Two Coats Of Approved Shade . The Works Is To Be Executed As Per Site Requirement And As Per Dimentions Of Pumping Unit And As Per Directions Of Site Engineer.Rest Of Specification / Details Are As Per Clause 21 Of Annexure C Of Sbd 111 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level 1:2:4 With Stone Aggregrate 20 Mm Nominal Size. For Dg Set Foundatioin / Concrete Beds For Rising-Main As Per Requirement 112 Centering And Shuttering Including Strutting, Propping Etc And Removal Of Form Work For Foundation, Footing , Base 113 Earth Work In Excavation By Manualmeans In Trenches For Foundations, Drains , Pipes , Cables Etc ( Not Exceeding 1.5 M In Width ) Andramming Of Bottoms Lift 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Exacavated Earth As Directed ( All Kinds Of Soil ) ( 2.81 Schedule ) 114 Providing And Laying Of Soling Stone 115 Cement Plaster In Find Sand In 1:3 Mix Finished With A Coat Of Neat Cement And Curing Complete 18 Mm Thick. ( S-11.8 ) 116 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter With 12V, 180Ah Tubular Inverter Batteryrest Details / Specification As Per Clause 54 Of Annexure C Of Sbd 117 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen . Rest Details / Specification As Per Clause 55Of Annexure C Of Sbd 118 Tool Kit For Maintenance: -The Tool Kit For Maintenance As Per Detailed Specification In Clause 56 Of Annexure C Of Sbd 119 Providing Of Good Quality Conveinence And Utility Items As Per Details In Clause57 Of Annexure C Of Sbd 120 Fabricationof6’ X 6’ Angle Iron Bedfor Operators. Rest Details / Specification As Per Clause 58 Of Annexure C Of Sbd 121 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 Nos. Rest Details / Specification As Per Clause 59 Of Annexure C Of Sbd 122 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply.Rest Details / Specification As Per Clause 60 Of Annexure C Of Sbd 123 Providing Of Bamboo Ladder 18 Feet Long With 15 Feet Long Link Rods And Ht Gloves Pair ( 01 Each ) Rest Details / Specification As Per Clause 61 Of Annexure C Of Sbd 124 Providing Of 1 Kw Heat Convector For Operators For Winter Season.Rest Details / Specification As Per Clause 62 Of Annexure C Of Sbd 125 Providing And Fitting Of 01 No. Led ( Scroll Type ) Sign Board Fabricated Out Of Stainless Steel And Metalrest Of Deatils / Technical Specification Are As Per Clause 63 Of Annexure C Of Sbd 126 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site. The Legs Are To Be Grouted In Cement Concrete.Rest Of Deatils / Technical Specification Are As Per Clause 64 Of Annexure C Of Sbd 127 Providing Corrugated G.S Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks , Bolts And Nuts For Dg Set And Overhead Gantryrest Of Deatils / Technical Specification Are As Per Clause 68 Of Annexure C Of Sbd 128 Stage 2Nd B 129 Providing, Fitting, Installation, Testing And Commissioning Of Hz Pumping Unit Of Approved Make Withfollowing Specifications: At Stage 2Nddischarge Of The Pump = 10000 Gph Dynamic Head = 48 M , With Head Range 25-60Speed = 1450 Rpmworking Voltage = 380 ± 15 V, 03 Phaserating = Corresponding To The Head And Discharge Not Less Than 20 Hp.Rest Of Specification / Details Are As Per Clause 5 Of Annexure C Of Sbd 130 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) For Y Junction And Washoutsize: 100Class:C ( Heavy ) Rest Of Specification As Per Clause 8 Of Annexure C Of Sbd 131 Cutting Of Hot Dip Galvanized Gi , C-Class Pipe Acoss The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Includes Providing And Welding Of M.S. Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17Dia: 100`Rest Of Specification As Per Clause 11 Of Annexure C Of Sbd 132 Fabrication , Providing And Fiting Of Y- Junction Havingminimum 1M Arm Length Of Each Arm To Be Fabricated Out Of G.I C Class Pipe With M.S. Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends.Dia: 100 Mmrest Of Specification As Per Clause 8 Of Annexure C Of Sbd 133 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seatedglandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .Size: Dn100pn:1.6 / 16 Rest Of Specification / Details Areas Per Clause 12 Of Annexure C Of Sbd 134 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size: 100Mmpn: 1.6 / 16Rest Of Specification / Details Areas Per Clause 13 Of Annexure C Of Sbd 135 Providing And Fitting Of 100 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 136 Providing And Fitting Of Flanged Washout Tee 100 Mm , Including Nuts, Bolts And Gasket As Per Site Requirement.Rest Of Specification / Details Areas Per Clause 09 Of Annexure C Of Sbd 137 Providing And Fitting Of 100 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 138 Providing And Fitting Of Flanged Washout Tee 100 Mm , Including Nuts, Bolts And Gasket As Per Site Requirement.Rest Of Specification / Details Areas Per Clause 09 Of Annexure C Of Sbd 139 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) For Y Junction And Washoutsize: 80Class:C ( Heavy ) Rest Of Specification As Per Clause 8 Of Annexure C Of Sbd 140 Cutting Of Hot Dip Galvanized Gi , C-Class Pipe Acoss The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Includes Providing And Welding Of M.S. Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17Dia: 80`Rest Of Specification As Per Clause 11 Of Annexure C Of Sbd 141 Providing And Fitting Of 80 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 142 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size: 80Mmpn: 1.6 / 16Rest Of Specification / Details Areas Per Clause 13 Of Annexure C Of Sbd 143 Providing, Installation, Testing And Commissioning Of 50 Kva Voltage Stabilizer Rest Details & Specification As Per Clause 44 Of Annexure C Of Sbd 144 Fabrication Providing And Fitting Of 3 Phase Modular Control Panel. The Technical Details / Ratings Of Various Components Of Modular Control Panel Are Given Below B. Main Circuit Breaker = 160 Ac. Changeover Switch = 160 Ad. Motor Breakup Protectionmccb= 100 Ae. Fasdstarter - 2 Units With Rating Line Contactor _Ac3 50 A , Delta Contactor- Ac3 50 Astar Contractor- Ac3 32Atimer- Star Delta Electronicthermal Overload Relay- With Relay Range 15-50 Direct / Ct Operated Suitable-Rangeaux Coil Voltage Wide Band Fitted With Seperate Stabilization Unit Min 1Kw Aux Wiringf ) . Auxillary Mccb =63 Ampwith S.C. Breaking Capacity Of36kag ) . Motor Protection Relay Suitablei ) M-Power Module For Mobile Starter & Earth Fault Relay J ) Water Level Controller Rest Of Deatils / Technical Specification Are As Per Clause 43 Ofannexure C Of Sbd 145 Providing, Installation And Testing Ofheavy Duty Manual Type Triple Spur Gear Chainpulley Block Along With Monorail Geared Travelling Trolley Having Followingfeaturesmake = Reputed Make Capacity = 3 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 Mrest Details / Specification As Per Clause 24 Of Annexure C Of Sbd 146 Earthing Of Panel Boad, Stabilizer, Motors, Heating Points, Lighting Points, D.G Setsrest Details As Per Clause 48 Of Annexure C Of Sbd 147 Construction Of Clear Water Sump Cum Pump House ( Civil Works ) 148 Earth Work In Excavation By Mechanical Means Over Areas ( Exceeding 30Cm And Up [ To 1.5Mtr In Depth, 1.5Mtr In Width As Well As 10 Sqm On Plan ) Including Disposal Of Excavated Earth Upto 50M From Cutting Edge Disposal Earth To Be Levelled And Neatly Dressed .All Kinds Of Soil 149 Extra For Earthwork In Excavation Beyond 1.5M 150 Providing And Laying Of Dry Stone Soling In Horizontal On Level. 151 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering.1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Agg. 40 Mm Nominal Size Crushed 152 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 153 Reinforced Cement Concrete Work In Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts Andstruts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement.1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 154 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Upto 15°, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Upto Five Level Including Curing But Excluding The Cost Of Centring, Shuttering, Finishing And Reinforcement With1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 155 Centering And Shuttering Including Strutting, Propping Etc, And Removal Of Form Work For Foundations, Footings, Bases For Columns 156 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Walls ( Any Thickness ) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs And Steps Etc. 157 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel , Beams & Cantilevers Etc 158 Extra For Shuttering In Circular Workfor Foundations, Footings, Bases For Columns 159 Extra For Shuttering In Circular Workfor Walls 160 Extra For Shuttering In Circular Work For Lintels, Beams & Cantilevers 161 Finishing Walls With Water Proofing Cement Paint Of Required Shade On New Work ( Two Or More Coats Applied @ 3.84 Kg / 10Sqm ) 162 Providing Corrugated G.S Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I Limpet Washers Or With G.I Limpet Washers Filled With White Lead And Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete ( Upto Any Pitch In Horizontal / Vertical Or Curved Surface ) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.50Mm Thick With Zinc Coating Not Less Than 275Gm / M2 163 Providing Ridges Or Hips Of Width 60Cm Over All Width Plain G.S Sheets With Polymer Coated J Or L Hooks, Bolts And Nuts 80Mm Dia G.I Limpet And Bitumen Washers Complete Job 164 Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete ( T.M.T Bars ) 165 Brick Work In Fps Bricksof Class Designation 75 In Foundation And Plinth In Cement Mortor 1:4 Mix 166 Extra For Brick Work With Common Burnt Clay Bricks / Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level 167 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia And Length ( Hold Fast Lugs Or With Dash Fasteners Shall Be Paid For Separately ) 2Nd Class Kail Wood 168 Providing And Fixing Wire Gauze Shutters Using Galvanized M.S. Wire Gauze Of Average Width For Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.63 Mm For Doors, Windows And Clerestory Windows With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws As Per Direction Of Engineer-In-Charge :First Class Kail Wood 169 Providing And Incorporating During Concreting G.P Strip Water Seal 0.63Mm Nominal Thick At Construction Joint As Per Proper Specification And Instruction Of Engineer Incharge Complete Job . 170 Providing And Fixing At Site Eaves Boarding Of 200Mmwide Colouredncluding Cost Of Holders, Angle Supports Complete Job 171 Providing And Fixing Of 0.5Mm Color Gs Sheet Soffitboardingincl Supports Etc Complete Job 172 15Mm Thick Cement Sand Plaster Finished With A Floating Coat Neat Cement Of Mix 1:4 1 Cement 4 Fine Sand 173 Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete.Welded 174 Pumping Out Water Caused By Springs, Tidal Or River Seepage, Broken Water Mains Or Drains And The Like 175 Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S Laths Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete Including The Cost Of Providing And Fixing Necessary 27.50Cm Long Wire Springs Manufacture From High Tensile Steel Wire Of Adequate Strength Confirming To Is 4454 Part 1 And M.S Top Cover Of Required Thickness For Rolling Shutters. 80X1.25Mm M.S Laths With 1.25Mm Thick Top Cover 176 Providing And Fixing Ball Bearing For Rolling Shutters 177 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 10Kg / Sqm ( 4Mm Thick ) Float Glass Panes Including Isi Marked M.S Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Second Class Kail Wood. 30Mm 178 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 179 Carriage Of Material By Mechanical Transport 180 Cement & Steel Avg Lead 5 Km 181 Sand & 20Mm Agg. For Average Lead Of 20Km 182 Bajree & 40Mm Agg.For Average Lead Of 20 Km 183 Stone Soling For 12 Km 184 Bricks For Average 80 Km 185 Construction Of Sinking Well Cum Pump House 186 Earth Work In Excavation By Mechanical Means Over Areas ( Exceeding 30Cm And Up [ To 1.5Mtr In Depth, 1.5Mtr In Width As Well As 10 Sqm On Plan ) Including Disposal Of Excavated Earth Upto 50M From Cutting Edge Disposal Earth To Be Levelled And Neatly Dressed .All Kinds Of Soil 187 Providing And Laying Of Dry Stone Soling In Horizontal On Level. 188 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering.1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Agg. 40 Mm Nominal Size Crushed 189 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 190 Reinforced Cement Concrete Work In Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts Andstruts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement.1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 191 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Upto 15°, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Upto Five Level Including Curing But Excluding The Cost Of Centring, Shuttering, Finishing And Reinforcement With1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 192 Centering And Shuttering Including Strutting, Propping Etc, And Removal Of Form Work For Foundations, Footings, Bases For Columns 193 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Walls ( Any Thickness ) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs And Steps Etc. 194 Centring And Shuttering Including Strutting, Propping Etc, And Removal Of Form Work For Suspended Floors, Roofs, Landings, Balconies And Access Platforms. 195 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel , Beams & Cantilevers Etc 196 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Edges Of Slabs 197 Extra For Shuttering In Circular Workfor Foundations, Footings, Bases For Columns 198 Extra For Shuttering In Circular Workfor Walls 199 Extra For Shuttering In Circular Work For Lintels, Beams & Cantilevers 200 Extra For Shuttering In Circular Work For Suspended Floors 201 Finishing Walls With Water Proofing Cement Paint Of Required Shade On New Work ( Two Or More Coats Applied @ 3.84 Kg / 10Sqm ) 202 Providing And Fixing Hand Rail Of Approved Size By Welding Etc To Steel Ladder Railing, Balcony Railing And Stair Case Railing And Similar Work Including Applying A Priming Coat Of Approved Steel Primer. M.S Tube ( Medium ) 40Mmm Nominal Bore 203 Providing Corrugated G.S Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I Limpet Washers Or With G.I Limpet Washers Filled With White Lead And Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete ( Upto Any Pitch In Horizontal / Vertical Or Curved Surface ) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.50Mm Thick With Zinc Coating Not Less Than 275Gm / M2 204 Providing Ridges Or Hips Of Width 60Cm Over All Width Plain G.S Sheets With Polymer Coated J Or L Hooks, Bolts And Nuts 80Mm Dia G.I Limpet And Bitumen Washers Complete Job 205 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work Over An Under Coat Ofsuitable Shade With Ordinary Paint Of Approved Brand And Manufacture. 206 Providing And Fixing 12Mm Thick Plyboard For Covering The Ceiling Area Incl C / O Frames, Supports , Battens Incl All Sorts Of Screws Etc Complete Job 207 Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete ( T.M.T Bars ) 208 Brick Work In Fps Bricksof Class Designation 75 In Foundation And Plinth In Cement Mortor 1:4 Mix 209 Extra For Brick Work With Common Burnt Clay Bricks / Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level 210 Providing And Fixing Wire Gauze Shutters Using Galvanized M.S. Wire Gauze Of Average Width For Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.63 Mm For Doors, Windows And Clerestory Windows With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws As Per Direction Of Engineer-In-Charge :First Class Kail Wood 211 Providing And Fixing At Site Eaves Boarding Of 200Mmwide Colouredncluding Cost Of Holders, Angle Supports Complete Job 212 Providing And Fixing Of 2Mm Ms Sheet Boardingincl Supports Etc Complete Job 213 15Mm Thick Cement Sand Plaster Finished With A Floating Coat Neat Cement Of Mix 1:4 ( 1 Cement : 4 Fine Sand ) 214 Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Welded 215 Supply, Fabrication, Fixing In Position Mild Steel Edge Cutter With Mild Steel Anchorage Including Welding And Making Position For Fixing Of Reinforcement Of Wall As Per Approved Drawings And Technical Specifications And As Per Instructions Of Site Engineer Incharge.Inld. All Carriages & Cots Compelete. 216 Sinking Of Well Through All Types Of Sink Complete As Per Drawings And All Technical Specificationby Way Of Making Of Platform Overhead Wall, With Loading, Unloading Of Sand Filled Ec Bags For Required Number Of Castings And Engagement Of Skilled Labour With Sinking Depth As Per Site Conditions And Removal Of Platform As Per Directions Of Site Engineer Incharge 217 Pumping Out Water Caused By Springs, Tidal Or River Seepage, Broken Water Mains Or Drains And The Like 218 Construction Of Earthern Bag Diversion Bund During The Construction Workby Way Of Laying Of Earth Bags Including, Sewing, Strings Loading, Unloading, Placing With Cost Of Bags, Earth And All Carraiges Involved At Site Including Removal ( Complete Job ) 219 Providing And Fixing Tie Bolt, Spring Coil And Plastic Cone In Wall Shuttering Complete As Per The Direction Of Engineer-In-Charge. 20 Mm Dia And 350 Mm Length 220 Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S Laths Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete Including The Cost Of Providing And Fixing Necessary 27.50Cm Long Wire Springs Manufacture From High Tensile Steel Wire Of Adequate Strength Confirming To Is 4454 Part 1 And M.S Top Cover Of Required Thickness For Rolling Shutters. 80X1.25Mm M.S Laths With 1.25Mm Thick Top Cover 221 Providing And Fixing Ball Bearing For Rolling Shutters 222 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 10Kg / Sqm ( 4Mm Thick ) Float Glass Panes Including Isi Marked M.S Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Second Class Kail Wood 223 Providing And Fixing Aluminium Handles Isi Marked Anodized ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour And Shade With Necessary Screws Etc Complete 100 Mm 224 Providing And Fixing Aluminium Tower Bolts Isi Marked Anodized ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc Complete 100 X 10Mm 225 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Depositedlayer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 226 Carriage Of Material By Mechanical Transport 227 Cement & Steel Avg Lead 5 Km 228 Sandfor Average Lead Of 20Km 229 Bajree For Average Lead Of 20 Km 230 Stone Soling For 12 Km 231 Bricks For Average 80 Km

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-10-2022 Extension of bid Date 24-10-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 428040.0 /-
Tender Value
INR 2.14 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail