}

Electro-Mechanical And Civil Works To Be Carried Out At Sangri Muqam ( Stage 1St And Stage 2Nd ) Electro-Mechanical And Civil Works-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowin, Baramulla-Jammu And Kashmir

Government Departments has published Electro-Mechanical And Civil Works To Be Carried Out At Sangri Muqam ( Stage 1St And Stage 2Nd ) Electro-Mechanical And Civil Works-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowin. Submission Date for this Tender is 24-10-2022. Cutting Crimping and Punching Tools Tenders in Baramulla Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

34092705
Corrigendum : Electro-Mechanical And Civil Works To Be Carried Out At Sangri Muqam ( Stage 1St And Stage 2Nd ) Electro-Mechanical And Civil Works-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowin
Open Tender
Indian
Jammu And Kashmir
Baramulla
24-10-2022

Tender Details

Electro-Mechanical And Civil Works To Be Carried Out At Sangri Muqam ( Stage 1St And Stage 2Nd ) Electro-Mechanical And Civil Works-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowing Specifications: At Stage 1St Discharge Of The Pump = 12500 Gph Dynamic Head = 130 M Speed = 1450 Rpmworking Voltage = 380 ± 15 V, 03 Phaserating = Corresponding To The Head And Discharge Not Less Than 60 Hp.Rest Of Specification / Details Are As Per Clause 6 Of Annexure C Of Sbd 3 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) For Y Junction And Washoutsize: 100Class:C ( Heavy ) Rest Of Specification As Per Clause 8 Of Annexure C Of Sbd 4 Cutting Of Hot Dip Galvanized Gi , C-Class Pipe Acoss The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Includes Providing And Welding Of M.S. Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17Dia: 100`Rest Of Specification As Per Clause 11 Of Annexure C Of Sbd 5 Fabrication , Providing And Fiting Of Y- Junction Havingminimum 1M Arm Length Of Each Arm To Be Fabricated Out Of G.I C Class Pipe With M.S. Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends.Dia: 100 Mmrest Of Specification As Per Clause 8 Of Annexure C Of Sbd 6 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seatedglandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .Size: Dn100pn:1.6 / 16 Rest Of Specification / Details Areas Per Clause 12 Of Annexure C Of Sbd 7 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size: 100Mmpn: 1.6 / 16Rest Of Specification / Details Areas Per Clause 13 Of Annexure C Of Sbd 8 Providing And Fitting Of 100 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 9 Providing And Fitting Of Flanged Washout Tee 100 Mm , Including Nuts, Bolts And Gasket As Per Site Requirement.Rest Of Specification / Details Areas Per Clause 09 Of Annexure C Of Sbd 10 Supply Installation , Testing And Commissioning Of Level Ii Ht Transfromercapacity: 100 Kvarest Of Specification / Details Areas Per Clause 26 Of Annexure C Of Sbd 11 9 M Long St-410 Sp33 Polerest Details As Per Clause 32 Of Annexure C Of Sbd 12 Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5 Cum / Pole 13 G.I V Cross With Top Bracket Including Clamps Rest Details As Per Clause 32 Of Annexure C Of Sbd 14 11 Kva Polymeric Insulators12 Kv , 5Kn , Lighting Impulse 75 Kv Positive And 80 Kv Negative With Creepage Distance 320Mmrest Details As Per Clause 31 Of Annexure C Of Sbd 15 Galvanized Nuts And Bolts ( 1Kg / Pole ) Rest Details As Per Clause 33 Of Annexure C Of Sbd 16 Red Oxide Coating Rest Details As Per Clause 37 Of Annexure C Of Sbd 17 Alumunium Paint Coating Rest Details As Per Clause 38 Of Annexure C Of Sbd 18 Acsr Conductor 50 Sqmmrest Details As Per Clause 39 Of Annexure C Of Sbd 19 Gi Channel / Angle / Flat Of Sizes Including Clamps 20 11 Kva Go , Ab Switch 3 Phase, 3 Pole, 200 A, Vertical Typerest Details As Per Clause 28 Of Annexure C Of Sbd 21 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45Kn, Lighting Impulse 75Kv Positive And 80 Kv Negative, Creepage Distance 320Mm 22 Gapless Surge Arrrestor 9Kv, 10 Ka , La With Polymer Housing, Stn Typerest Details As Per Clause 30 Of Annexure C Of Sbd 23 Earthing Of Substation- Rest Details As Per Clause 48 Of Annexure C Of Sbd 24 Galvanised Stay Set With 50X8mm Stay Clam, Guy Insulators ( 2NoS ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts, 2 Nos; Turn-Buckles, 1.8M Long, 16Mm Dia Meter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Completerest Details As Per Clause 36 Of Annexure C Of Sbd 25 Sundry Items Like Alumunium Lugs , Jumprs, Binding Tape 26 Providing & Fitting Of35 Sq Mm Single Core Copper Conductor ( Flexible ) Pvc Insulated Heavy Duty Industrial Cables ( Unsheathed ) , 1100 Volts Conforming To Is: 694- For Connecting Motors From Panel , Stabilizers In Rubber Conduit . Job Includes Providing& Laying Of Flexible Conduit For Cu Cable With Lugs As Per Requirement Heat Shrinkable Outdoor Cable Termination Kitrest Details As Per Clause 73 Of Annexure C Of Sbd 27 Providing, Installation , Testing Of Power Service Cablefor Workingvoltage Up To And Including 1100 Volts;95 Sq Mm Armored Aluminum 3.5 Core Cable As Service Line From Output Terminals Of Ht / Lt Transformerto Cubical Panel. Cost Includes Laying Of Cable In Trenches In Pvc Conduit Where Ever Itis To Be Laid Underground As Per Site Requirement Included Is Termination Of Ends With Suitable Aluminum Tube Terminals Dully Crimpled & Taped. Rest Specifications As Per Clause 68 Of Annexure C Of Sbd 28 Providing, Installation, Testing And Commissioning Of 100 Kva Voltage Stabilizer Rest Details & Specification As Per Clause 44 Of Annexure C Of Sbd 29 Fabrication Providing And Fitting Of 3 Phase Modular Control Panel. The Technical Details / Ratings Of Various Components Of Modular Control Panel Are Given Below B. Main Circuit Breaker = 250 Ac. Changeover Switch = 200 Ad. Motor Breakup Protectionmccb= 200 Ae. Fasdstarter - 2 Units With Rating Line Contactor _Ac3 110 A , Delta Contactor- Ac3 110 Astar Contractor- Ac3 90 Atimer- Star Delta Electronicthermal Overload Relay- With Relay Range 50-90 Direct / Ct Operated Suitable-Rangeaux Coil Voltage Wide Band Fitted With Seperate Stabilization Unit Min 1Kw Aux Wiringf ) . Auxillary Mccb =63 Ampwith S.C. Breaking Capacity Of36kag ) . Motor Protection Relay Suitablei ) M-Power Module For Mobile Starter & Earth Fault Relay J ) Water Level Controller Rest Of Deatils / Technical Specification Are As Per Clause 43 Ofannexure C Of Sbd 30 Providing, Installation And Testing Ofheavy Duty Manual Type Triple Spur Gear Chainpulley Block Along With Monorail Geared Travelling Trolley Having Followingfeaturesmake = Reputed Make Capacity = 3 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 Mrest Details / Specification As Per Clause 24 Of Annexure C Of Sbd 31 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole Rest Of Deatils / Technical Specification Are As Per Clause 50 Ofannexure C Of Sbd 32 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole , Including Mcb Fiited In Box 10Arest Details / Specification As Per Clause 51 Of Annexure C Of Sbd 33 Providing And Installation Of Junction Box With Dp 32Amp Mcb To Serve As Amin Switch For Led Lighting Including Complete Wiring Min 20-30 M From Panel Board.Rest Details / Specification As Per Clause 52 Of Annexure C Of Sbd 34 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer , Including Wiringrest Details / Specification As Per Clause 53 Of Annexure C Of Sbd 35 Providing & Fitting Oflighting Points For ( Machine Room , Operators Room, ) As Per Site Requirement In 1.5 Mm² Multistranded Single Core 1100 Volts, Pvc Insulatedcopper Conductor Through Pvcconduit Pipe By Way, Switches, Socket Modules , Regulators , Indicators, 08 / 10 Watt Led Lamps Surface Light Make. .Included Is Cost On Account Of Modular Switch Boards With The Wooden Frames As Per Site Requirements 36 Providing Fitting Of Heating Points In 2.5Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit By Way Of P / F Of 15 Amp Switches, 6 Pin Socketon Modularfittingas Per Site Requirements. Heating Points Are To Be Connected From Main Control Panel. All Accessories Required Is To Be Provided By The Firm 37 Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. Make Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. 38 Providing, Fitting Of Distribution Board Of Reputed Make 4 Way S P N Single Door Powder Coated Sheet Steel Enclosure For Surface Mounting Fitted With Bus Bar, Din Channel, Neutral Link And Incoming Contact. The Above Db Is To Be Provided / Fitted With Double Pole 40 Amp Mcb For Main. 32 A For Heating Circuit & Rest 3 Of 16 / 6 Amps Each For Premises Luminary, Auxiliary Circuit Of Reputed Make. Further Job Includes Providing / Fitting 4 Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit As Service Line From Main Panel As Per Site Requirements. Connections Should Be Made In Such A Way Lighting Pointsis To Be Connected Via Automatic Transformer By Way Of P / F Switch Socket Arrangement With Allied Fixtures & And Heating Points To Main Panel. Job Includes Dismantling Of Existing Damaged Conduit , Wires, Conduit And Cleaning The Surface Properly 39 Earthing Of Panel Boad, Stabilizer, Motors, Heating Points, Lighting Points, D.G Setsrest Details As Per Clause 48 Of Annexure C Of Sbd 40 Painting On Steel Structure / Pipe With Synthetic Enamel Paint Of Approved Brand And Maufacturer Of Required Colour To Give An Even Shade On New Work ( Two Or More Coats ) Including A Coat Of Approved Steel Primer But Excluding A Coat Of Mordant Solution. ( Ref 13.61 ) Schedule2021 41 Fabrication, Providing, Fitting Of Base Framefor Pumping Units , Covering Of Holes , Fabrication Of Gantry, Ladder , Dg Set Covering, Ht / Lt Transformer Bed With Gantry Fabricated Out Of Ismc / Ismb / Isa / Bars / Ms Pipe / Ms Plain-Chequrred Sheets. Including Making Of Holes In Concrete, Including Metal Primer 1 Coat And Two Coats Of Approved Shade . The Works Is To Be Executed As Per Site Requirement And As Per Dimentions Of Pumping Unit And As Per Directions Of Site Engineer.Rest Of Specification / Details Are As Per Clause 21 Of Annexure C Of Sbd 42 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level 1:2:4 With Stone Aggregrate 20 Mm Nominal Size. For Dg Set Foundatioin / Concrete Beds For Rising-Main As Per Requirement 43 Centering And Shuttering Including Strutting, Propping Etc And Removal Of Form Work For Foundation, Footing , Base 44 Earth Work In Excavation By Manualmeans In Trenches For Foundations, Drains , Pipes , Cables Etc ( Not Exceeding 1.5 M In Width ) Andramming Of Bottoms Lift 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Exacavated Earth As Directed ( All Kinds Of Soil ) ( 2.81 Schedule ) 45 Providing And Laying Of Soling Stone 46 Cement Plaster In Find Sand In 1:3 Mix Finished With A Coat Of Neat Cement And Curing Complete 18 Mm Thick. ( S-11.8 ) 47 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter With 12V, 180Ah Tubular Inverter Batteryrest Details / Specification As Per Clause 54 Of Annexure C Of Sbd 48 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen . Rest Details / Specification As Per Clause 55Of Annexure C Of Sbd 49 Tool Kit For Maintenance: -The Tool Kit For Maintenance As Per Detailed Specification In Clause 56 Of Annexure C Of Sbd 50 Providing Of Good Quality Conveinence And Utility Items As Per Details In Clause57 Of Annexure C Of Sbd 51 Fabricationof6’ X 6’ Angle Iron Bedfor Operators. Rest Details / Specification As Per Clause 58 Of Annexure C Of Sbd 52 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 Nos. Rest Details / Specification As Per Clause 59 Of Annexure C Of Sbd 53 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply.Rest Details / Specification As Per Clause 60 Of Annexure C Of Sbd 54 Providing Of Bamboo Ladder 18 Feet Long With 15 Feet Long Link Rods And Ht Gloves Pair ( 01 Each ) Rest Details / Specification As Per Clause 61 Of Annexure C Of Sbd 55 Providing Of 1 Kw Heat Convector For Operators For Winter Season.Rest Details / Specification As Per Clause 62 Of Annexure C Of Sbd 56 Providing And Fitting Of 01 No. Led ( Scroll Type ) Sign Board Fabricated Out Of Stainless Steel And Metalrest Of Deatils / Technical Specification Are As Per Clause 63 Of Annexure C Of Sbd 57 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site. The Legs Are To Be Grouted In Cement Concrete.Rest Of Deatils / Technical Specification Are As Per Clause 64 Of Annexure C Of Sbd 58 Providing Corrugated G.S Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks , Bolts And Nuts For Dg Set And Overhead Gantryrest Of Deatils / Technical Specification Are As Per Clause 68 Of Annexure C Of Sbd 59 Stage 2Nd 60 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowing Specifications: At Stage 1St Discharge Of The Pump = 11000 Gph Dynamic Head = 145 M Speed = 1450 Rpmworking Voltage = 380 ± 15 V, 03 Phaserating = Corresponding To The Head And Discharge Not Less Than 60 Hp.Rest Of Specification / Details Are As Per Clause 6 Of Annexure C Of Sbd 61 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) For Y Junction And Washoutsize: 100Class:C ( Heavy ) Rest Of Specification As Per Clause 8 Of Annexure C Of Sbd 62 Cutting Of Hot Dip Galvanized Gi , C-Class Pipe Acoss The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Includes Providing And Welding Of M.S. Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17Dia: 100`Rest Of Specification As Per Clause 11 Of Annexure C Of Sbd 63 Fabrication , Providing And Fiting Of Y- Junction Havingminimum 1M Arm Length Of Each Arm To Be Fabricated Out Of G.I C Class Pipe With M.S. Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends.Dia: 100 Mmrest Of Specification As Per Clause 8 Of Annexure C Of Sbd 64 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seatedglandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .Size: Dn100pn:1.6 / 16 Rest Of Specification / Details Areas Per Clause 12 Of Annexure C Of Sbd 65 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size: 100Mmpn: 1.6 / 16Rest Of Specification / Details Areas Per Clause 13 Of Annexure C Of Sbd 66 Providing And Fitting Of 100 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 67 Providing And Fitting Of Flanged Washout Tee 100 Mm , Including Nuts, Bolts And Gasket As Per Site Requirement.Rest Of Specification / Details Areas Per Clause 09 Of Annexure C Of Sbd 68 Supply Installation , Testing And Commissioning Of Level Ii Ht Transfromercapacity: 100 Kvarest Of Specification / Details Areas Per Clause 26 Of Annexure C Of Sbd 69 9 M Long St-410 Sp33 Polerest Details As Per Clause 32 Of Annexure C Of Sbd 70 Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5 Cum / Pole 71 G.I V Cross With Top Bracket Including Clamps Rest Details As Per Clause 32 Of Annexure C Of Sbd 72 11 Kva Polymeric Insulators12 Kv , 5Kn , Lighting Impulse 75 Kv Positive And 80 Kv Negative With Creepage Distance 320Mmrest Details As Per Clause 31 Of Annexure C Of Sbd 73 Galvanized Nuts And Bolts ( 1Kg / Pole ) Rest Details As Per Clause 33 Of Annexure C Of Sbd 74 Red Oxide Coating Rest Details As Per Clause 37 Of Annexure C Of Sbd 75 Alumunium Paint Coating Rest Details As Per Clause 38 Of Annexure C Of Sbd 76 Acsr Conductor 50 Sqmmrest Details As Per Clause 39 Of Annexure C Of Sbd 77 Gi Channel / Angle / Flat Of Sizes Including Clamps 78 11 Kva Go , Ab Switch 3 Phase, 3 Pole, 200 A, Vertical Typerest Details As Per Clause 28 Of Annexure C Of Sbd 79 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45Kn, Lighting Impulse 75Kv Positive And 80 Kv Negative, Creepage Distance 320Mm 80 Gapless Surge Arrrestor 9Kv, 10 Ka , La With Polymer Housing, Stn Typerest Details As Per Clause 30 Of Annexure C Of Sbd 81 Earthing Of Substation- Rest Details As Per Clause 48 Of Annexure C Of Sbd 82 Galvanised Stay Set With 50X8mm Stay Clam, Guy Insulators ( 2NoS ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts, 2 Nos; Turn-Buckles, 1.8M Long, 16Mm Dia Meter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Completerest Details As Per Clause 36 Of Annexure C Of Sbd 83 Sundry Items Like Alumunium Lugs , Jumprs, Binding Tape 84 Providing & Fitting Of35 Sq Mm Single Core Copper Conductor ( Flexible ) Pvc Insulated Heavy Duty Industrial Cables ( Unsheathed ) , 1100 Volts Conforming To Is: 694- For Connecting Motors From Panel , Stabilizers In Rubber Conduit . Job Includes Providing& Laying Of Flexible Conduit For Cu Cable With Lugs As Per Requirement Heat Shrinkable Outdoor Cable Termination Kitrest Details As Per Clause 73 Of Annexure C Of Sbd 85 Providing, Installation , Testing Of Power Service Cablefor Workingvoltage Up To And Including 1100 Volts;95 Sq Mm Armored Aluminum 3.5 Core Cable As Service Line From Output Terminals Of Ht / Lt Transformerto Cubical Panel. Cost Includes Laying Of Cable In Trenches In Pvc Conduit Where Ever Itis To Be Laid Underground As Per Site Requirement Included Is Termination Of Ends With Suitable Aluminum Tube Terminals Dully Crimpled & Taped. Rest Specifications As Per Clause 68 Of Annexure C Of Sbd 86 Providing, Installation, Testing And Commissioning Of 100 Kva Voltage Stabilizer Rest Details & Specification As Per Clause 44 Of Annexure C Of Sbd 87 Fabrication Providing And Fitting Of 3 Phase Modular Control Panel. The Technical Details / Ratings Of Various Components Of Modular Control Panel Are Given Below B. Main Circuit Breaker = 250 Ac. Changeover Switch = 200 Ad. Motor Breakup Protectionmccb= 200 Ae. Fasdstarter - 2 Units With Rating Line Contactor _Ac3 110 A , Delta Contactor- Ac3 110 Astar Contractor- Ac3 90 Atimer- Star Delta Electronicthermal Overload Relay- With Relay Range 50-90 Direct / Ct Operated Suitable-Rangeaux Coil Voltage Wide Band Fitted With Seperate Stabilization Unit Min 1Kw Aux Wiringf ) . Auxillary Mccb =63 Ampwith S.C. Breaking Capacity Of36kag ) . Motor Protection Relay Suitablei ) M-Power Module For Mobile Starter & Earth Fault Relay J ) Water Level Controller Rest Of Deatils / Technical Specification Are As Per Clause 43 Ofannexure C Of Sbd 88 Providing, Installation And Testing Ofheavy Duty Manual Type Triple Spur Gear Chainpulley Block Along With Monorail Geared Travelling Trolley Having Followingfeaturesmake = Reputed Make Capacity = 3 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 Mrest Details / Specification As Per Clause 24 Of Annexure C Of Sbd 89 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole Rest Of Deatils / Technical Specification Are As Per Clause 50 Ofannexure C Of Sbd 90 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole , Including Mcb Fiited In Box 10Arest Details / Specification As Per Clause 51 Of Annexure C Of Sbd 91 Providing And Installation Of Junction Box With Dp 32Amp Mcb To Serve As Amin Switch For Led Lighting Including Complete Wiring Min 20-30 M From Panel Board.Rest Details / Specification As Per Clause 52 Of Annexure C Of Sbd 92 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer , Including Wiringrest Details / Specification As Per Clause 53 Of Annexure C Of Sbd 93 Providing & Fitting Oflighting Points For ( Machine Room , Operators Room, ) As Per Site Requirement In 1.5 Mm² Multistranded Single Core 1100 Volts, Pvc Insulatedcopper Conductor Through Pvcconduit Pipe By Way, Switches, Socket Modules , Regulators , Indicators, 08 / 10 Watt Led Lamps Surface Light Make. .Included Is Cost On Account Of Modular Switch Boards With The Wooden Frames As Per Site Requirements 94 Providing Fitting Of Heating Points In 2.5Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit By Way Of P / F Of 15 Amp Switches, 6 Pin Socketon Modularfittingas Per Site Requirements. Heating Points Are To Be Connected From Main Control Panel. All Accessories Required Is To Be Provided By The Firm 95 Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. Make Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. 96 Providing, Fitting Of Distribution Board Of Reputed Make 4 Way S P N Single Door Powder Coated Sheet Steel Enclosure For Surface Mounting Fitted With Bus Bar, Din Channel, Neutral Link And Incoming Contact. The Above Db Is To Be Provided / Fitted With Double Pole 40 Amp Mcb For Main. 32 A For Heating Circuit & Rest 3 Of 16 / 6 Amps Each For Premises Luminary, Auxiliary Circuit Of Reputed Make. Further Job Includes Providing / Fitting 4 Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit As Service Line From Main Panel As Per Site Requirements. Connections Should Be Made In Such A Way Lighting Pointsis To Be Connected Via Automatic Transformer By Way Of P / F Switch Socket Arrangement With Allied Fixtures & And Heating Points To Main Panel. Job Includes Dismantling Of Existing Damaged Conduit , Wires, Conduit And Cleaning The Surface Properly 97 Earthing Of Panel Boad, Stabilizer, Motors, Heating Points, Lighting Points, D.G Setsrest Details As Per Clause 48 Of Annexure C Of Sbd 98 Painting On Steel Structure / Pipe With Synthetic Enamel Paint Of Approved Brand And Maufacturer Of Required Colour To Give An Even Shade On New Work ( Two Or More Coats ) Including A Coat Of Approved Steel Primer But Excluding A Coat Of Mordant Solution. ( Ref 13.61 ) Schedule2021 99 Fabrication, Providing, Fitting Of Base Framefor Pumping Units , Covering Of Holes , Fabrication Of Gantry, Ladder , Dg Set Covering, Ht / Lt Transformer Bed With Gantry Fabricated Out Of Ismc / Ismb / Isa / Bars / Ms Pipe / Ms Plain-Chequrred Sheets. Including Making Of Holes In Concrete, Including Metal Primer 1 Coat And Two Coats Of Approved Shade . The Works Is To Be Executed As Per Site Requirement And As Per Dimentions Of Pumping Unit And As Per Directions Of Site Engineer.Rest Of Specification / Details Are As Per Clause 21 Of Annexure C Of Sbd 100 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level 1:2:4 With Stone Aggregrate 20 Mm Nominal Size. For Dg Set Foundatioin / Concrete Beds For Rising-Main As Per Requirement 101 Centering And Shuttering Including Strutting, Propping Etc And Removal Of Form Work For Foundation, Footing , Base 102 Earth Work In Excavation By Manualmeans In Trenches For Foundations, Drains , Pipes , Cables Etc ( Not Exceeding 1.5 M In Width ) Andramming Of Bottoms Lift 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Exacavated Earth As Directed ( All Kinds Of Soil ) ( 2.81 Schedule ) 103 Providing And Laying Of Soling Stone 104 Cement Plaster In Find Sand In 1:3 Mix Finished With A Coat Of Neat Cement And Curing Complete 18 Mm Thick. ( S-11.8 ) 105 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter With 12V, 180Ah Tubular Inverter Batteryrest Details / Specification As Per Clause 54 Of Annexure C Of Sbd 106 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen . Rest Details / Specification As Per Clause 55Of Annexure C Of Sbd 107 Tool Kit For Maintenance: -The Tool Kit For Maintenance As Per Detailed Specification In Clause 56 Of Annexure C Of Sbd 108 Providing Of Good Quality Conveinence And Utility Items As Per Details In Clause57 Of Annexure C Of Sbd 109 Fabricationof6’ X 6’ Angle Iron Bedfor Operators. Rest Details / Specification As Per Clause 58 Of Annexure C Of Sbd 110 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 Nos. Rest Details / Specification As Per Clause 59 Of Annexure C Of Sbd 111 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply.Rest Details / Specification As Per Clause 60 Of Annexure C Of Sbd 112 Providing Of Bamboo Ladder 18 Feet Long With 15 Feet Long Link Rods And Ht Gloves Pair ( 01 Each ) Rest Details / Specification As Per Clause 61 Of Annexure C Of Sbd 113 Providing Of 1 Kw Heat Convector For Operators For Winter Season.Rest Details / Specification As Per Clause 62 Of Annexure C Of Sbd 114 Providing And Fitting Of 01 No. Led ( Scroll Type ) Sign Board Fabricated Out Of Stainless Steel And Metalrest Of Deatils / Technical Specification Are As Per Clause 63 Of Annexure C Of Sbd 115 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site. The Legs Are To Be Grouted In Cement Concrete.Rest Of Deatils / Technical Specification Are As Per Clause 64 Of Annexure C Of Sbd 116 Providing Corrugated G.S Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks , Bolts And Nuts For Dg Set And Overhead Gantryrest Of Deatils / Technical Specification Are As Per Clause 68 Of Annexure C Of Sbd 117 Civil Works 118 Earth Work In Excavation By Mannual Means Over Areas ( Exceeding 30Cm And Upto 1.5M In Depth And Width As Well As 10 Sqm In Plan ) Including Disposal Of Excavated Earth Upto 1M Cutting Edge, Disposed Earth To Be Levelled And Neatly Dressed In All Kinds Of Soil. 119 Earth Work In Excavation By Mechanical Means Over Areas ( Exceeding 30Cm And Up [ To 1.5Mtr In Depth, 1.5Mtr In Width As Well As 10 Sqm On Plan ) Including Disposal Of Excavated Earth Upto 50M From Cutting Edge Disposal Earth To Be Levelled And Neatly Dressed .All Kinds Of Soil 120 Extra For Earthwork In Excavation Beyond 1.5M 121 Providing And Laying Of Dry Stone Soling In Horizontal On Level. 122 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering.1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Agg. 40 Mm Nominal Size Crushed 123 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) 124 Reinforced Cement Concrete Work In Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts Andstruts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement.1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 125 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge. All Works Uptoplinth Level . 126 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.All Works Aboveplinth Level . 127 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Foundations 128 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Walls ( Any Thickness ) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs And Steps Etc. 129 Centring And Shuttering Including Strutting, Propping Etc, And Removal Of Form Work For Suspended Floors, Roofs, Landings, Balconies And Access Platforms. 130 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel , Beams & Cantilevers Etc 131 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Spiral Stair, Landings 132 Extra For Shuttering In Circular Workfor Foundations, Footings, Bases For Columns 133 Extra For Shuttering In Circular Workfor Walls 134 Extra For Shuttering In Circular Work For Lintels, Beams & Cantilevers 135 Extra For Shuttering In Circular Work For Spiral Stair, Landing 136 Finishing Walls With Water Proofing Cement Paint Of Required Shade On New Work ( Two Or More Coats Applied @ 3.84 Kg / 10Sqm ) 137 Applying Priming Coat:With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work ( Hard And Soft Wood ) 138 Distempering With Oil Bond Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade. New Worl One Or More Coats 139 Providing , Hoisting, Trusses, Perlins, Rafters, Posts Or Like Componants Including Cost Of Screws, Nails Complete Of Fir / Badloo 140 Providing Corrugated G.S Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I Limpet Washers Or With G.I Limpet Washers Filled With White Lead And Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete ( Upto Any Pitch In Horizontal / Vertical Or Curved Surface ) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.50Mm Thick With Zinc Coating Not Less Than 275Gm / M2 141 Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete ( T.M.T Bars ) 142 Providing And Mixing Water Proofing Material In Cement Concrete Work In Doses By Weight Of Cement As Per Manufacturer’S Specification. ( 1 Kg Of Water Proofing Material In 50 Kg Of Cement ) 143 Brick Work In Fps Bricksof Class Designation 75 In Foundation And Plinth In Cement Mortor 1:4 Mix 144 Extra For Brick Work With Common Burnt Clay Bricks / Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level 145 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge, Using First Class Kail Wood 35Mm Thick. 146 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia And Length ( Hold Fast Lugs Or With Dash Fasteners Shall Be Paid For Separately ) 2Nd Class Kail Wood 147 Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows ( Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured ) . Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40Mm Thick.For Door 148 Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows ( Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured ) . Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40Mm Thick.For Glass Panes 4Mm Thick For Exterior Window Shutters 149 C ) Fly Proof Stainless Steel Grade 304 Wire Gauge With 0.5 Mm Dia Wire And 1.4 Mm Wide Aperture With Matching Wood Beading 150 Extra For Plastering On Circular Work One Coat. 151 Applying Priming Coat With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brandand Manufacture On Steel Galvanised Iron / Steel Work 152 Painting With Synthetic Enamel Paint Of Approved Brandand Manufacture On Steel Galvanised Iron / Steel Work 153 Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S Laths Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete Including The Cost Of Providing And Fixing Necessary 27.50Cm Long Wire Springs Manufacture From High Tensile Steel Wire Of Adequate Strength Confirming To Is 4454 Part 1 And M.S Top Cover Of Required Thickness For Rolling Shutters. 80X1.25Mm M.S Laths With 1.25Mm Thick Top Cover 154 Providing And Fixing Ball Bearing For Rolling Shutters 155 Providing And Fixing Aluminium Handles Isi Marked Anodized ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour And Shade With Necessary Screws Etc Complete 125 Mm 156 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M 157 Carriage Of Material By Mechanical Transport 158 Cement & Steel Avg Lead 5 Km 159 Sandfor Average Lead Of 20Km 160 40Mm Aggegrate For Average Lead Of 20 Km 161 Stone Soling For 12 Km 162 Bricks For Average 80 Km

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-10-2022 Extension of bid Date 24-10-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 327760.0 /-
Tender Value
INR 1.63 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail