Eoi For Empanelment Of Manufacturers Of Submersible Pumpsets For Supply, Installation And Electrification ( Energization ) Of Irrigation Submersible Pumpset Along With Its Accessories Suitable For 165Mm Dia Borewells Under Ganga Kalyana Scheme For The Year 2020-21, 2021-22 And 2022-23.In The Development Corporations Coming Under Backward Classes Welfare Department. , Submersible Pump Sets - 5 Hp 10 Stage, Submersible Pump Sets- 5 Hp 12 Stage, Submersible Pump Sets -7.5 Hp 12 Stage, Submersible Pump Sets- 7.5 Hp 15 Stage, Submersible Pump Sets -7.5 Hp 20 Stage, Submersible Pump Sets -10 Hp 20 Stage, Submersible Pump Sets -10 Hp 30 Stage, Submersible Pump Sets- 12.5 Hp 20 Stage, Submersible Pump Sets - 12.5 Hp 30 Stage, Submersible Pump Sets- 15 Hp 30 Stage, Submersible Pump Sets - 15 Hp 35 Stage, Submersible Pump Sets - 17.5 Hp 26 Stage, Submersible Pump Sets - 17.5 Hp 35 Stage, Submersible Pump Sets- 20 Hp 30 Stage, Submersible Pump Sets - 20 Hp 40 Stage, Providing, Gi Pipes Conforming To Is 1239:1990 With Latest Amendments Complete With Cuts And Threads Wherever Necessary, Including Testing For Water Tightness, With All Lead And Commissioning. ( Contractor Will Make His Own Arrangements For Procuring Water For Testing ) For Medium Duty Gi Pipe Class ‘B’ Medium Duty Size-50 Mm., Providing Mild Steel ( Galvanized ) 50 Mm Dia Gi Collar Confirming To Is 1239-Ii, 1991 With Latest Amendments If Any. 50Mm, Supply And Delivery At Site 50Mm ( 2” ) Dia Heavy Duty Unplasticized Upvc Column Pipes With Heavy Duty Collars, Rubber Profile Ring, Vibration Control Profile Ring, Freezing And Turbulence Free Leak Proof Epdm Ring With Isi Mark With Its Latest Amendments, Supply And Delivery At Site 50Mm ( 2” ) Dia Heavy Duty Gi Adopter Set Complete Suitable For Upvc Column Pipes For Submersible Pumpsets., Supply And Delivery At Site Brand New Best Make Pvc Insulated Cable Of Flat 3 Core ( Sheathed ) Of Nominal Cross-Sectional Area As Per Is 694-2010 With Isi Mark And As Per Its Latest Amendments - 1X3x2.5 Sqmm, Supply And Delivery At Site Brand New Best Make Pvc Insulated Cable Of Flat 3 Core ( Sheathed ) Of Nominal Cross-Sectional Area As Per Is 694-2010 With Isi Mark And As Per Its Latest Amendments - 1X3x4 Sqmm, Supply And Delivery At Site Brand New Best Make Pvc Insulated Cable Of Flat 3 Core ( Sheathed ) Of Nominal Cross-Sectional Area As Per Is 694-2010 With Isi Mark And As Per Its Latest Amendments - 1X3x6 Sqmm, Supply And Delivery At Site Of Brand New Best Make Gate Valve As Per Is 778 / 1984 With Isi Mark And As Per Its Latest Amendments- Size 50 Mm, Supply And Delivery At Site Of Brand New Best Make Non-Return Valve As Per Is 778 / 1984 With Isi Mark And As Per Its Latest Amendments- Size 50 Mm, Supply And Delivery At Site Mild Steel ( Galvanized ) Gi Bend Confirming To Is 1239-Ii, 1991 With Latest Amendments If Any. Size-50 Mm, Supply And Delivery At Site Mild Steel ( Galvanized ) Gi Hexagonal Nipple Confirming To Is 1239-Ii, 1991 With Latest Amendments If Any. Size-50 Mm, Supply, Installing, Testing And Commissioning Common Control Panel Consisting Of The Following Incoming:1 No Set Of Phase Indicating Lamps With Sfu Of Suitable Rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1Ni With Phase Selector Switch, Isolating Switch Outgoing For Main Electrical Pump: 1 No. Mcb 1 No. Dol Of S / D Starter Suitable For Respective Hp 1 No. Electrical Protection Like Single Phase Preventer, Under Voltage Over Volage, Under Current Over Current & Dry Run Protection Suitable For The Pump Described Above 1 No For Outdoor Type-Upto 6 Hp Pumps, Supply, Installing, Testing And Commissioning Common Control Panel Consisting Of The Following Incoming:1 No Set Of Phase Indicating Lamps With Sfu Of Suitable Rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1Ni With Phase Selector Switch, Isolating Switch Outgoing For Main Electrical Pump: 1 No. Mcb 1 No. Dol Of S / D Starter Suitable For Respective Hp 1 No. Electrical Protection Like Single Phase Preventer, Under Voltage Over Volage, Under Current Over Current & Dry Run Protection Suitable For The Pump Described Above 1 No For Outdoor Type-6 To 15 Hp Pumps, Supply, Installing, Testing And Commissioning Common Control Panel Consisting Of The Following Incoming:1 No Set Of Phase Indicating Lamps With Sfu Of Suitable Rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1Ni With Phase Selector Switch, Isolating Switch Outgoing For Main Electrical Pump: 1 No. Mcb 1 No. Dol Of S / D Starter Suitable For Respective Hp 1 No. Electrical Protection Like Single Phase Preventer, Under Voltage Over Volage, Under Current Over Current & Dry Run Protection Suitable For The Pump Described Above 1 No For Outdoor Type-15 To 20 Hp Pumps, Supply And Delivery At Site Best Indigenous Brand New Power Capacitor As Per Is 2834 / 1986 With Latest Amendments With Kptcl Authorities And Erection, Electrification And Commissioning Of The Same At The Location Of Respective Pump Sets. – Kvar, Supply And Delivery At Site Delivery Of Best Indigenous Brand New Mcb ( Miniature Circuit Breakers ) Of Required Capacity As Per Is 88228 / 1978 And Its Latest Amendments And With Isi Mark Of 6 / 10 / 16 / 20 / 25 / 40 Amps With Scalable Box ( Per 3 Poles ) , Providing, Supplying And Fixing Suitable For 1.1 Kv Class Ug Cable Filled With Necessary Bitumen / Insulating Compound Complete With Terminals, Clamps, Bolts, Nuts And Washers Etc. With Necessary Materials And Labour Tools And Equipment’S As Per Instructions Of Engineer Incharge Of Work. –3.5 X 10 Sq Mm, Providing, Supplying And Fixing Suitable For 1.1 Kv Class Ug Cable Filled With Necessary Bitumen / Insulating Compound Complete With Terminals, Clamps, Bolts, Nuts And Washers Etc. With Necessary Materials And Labour Tools And Equipment’S As Per Instructions Of Engineer Incharge Of Work. – 3.5 X 25 Sq Mm, Providing, Laying And Fixing Gi Pipes Conforming To Is 1239:1990 With Latest Amendments Complete With Gi Fittings ( Excluding The Cost Of Fittings ) With Cuts And Threads Wherever Necessary, Including Testing For Water Tightness, With All Lead And Commissioning. ( Contractor Will Make His Own Arrangements For Procuring Water For Testing ) -Light Duty -40Mm ‘A’ Class For Earthing., Labour Charges For Erection, Electrification And Commissioning Of Pump Sets, Including Aligning And Balancing Of All Items Including Supply And Erection Of Two Pair Of Supporting Clamps, Bore Well Caps, Cable Clips And Water-Tight Gland Cable Protectors, Bolts, Nuts, Valve And Gauges, Tools And Equipment’S Etc., Involved In The Job As Per Specifications, With Necessary Tests As Per Specifications, With Testing Of As Per Instructions Of Engineer In Charge Of Work., Labour Charges For Erection Of Outdoor Type Panel Board And Meter Board Units With All Necessary Materials And Labour, Tools And Equipment’S Including Providing Cement Concrete Foundation Bed Etc., Complete As Per Specification, With Testing Of As Per Instructions Of Engineer In Charge Of Work., Providing Main Connection From Pole Pvc Insulated Sheathed Steel Wire Cable In New Trench As Per Is 1554 / 1988 With Latest Amendments With Isi Mark From Kptcl Pole To Meter Board Unit., Digging Of Trench Of 0.6 Mtr Deep X 0.50 Mtr Wide Refilling The Trench To The Required Ground Level And Consolidating, Etc. Complete As Per Instructions Of Engineer / Assigned Officers Incharge Of Work - In Soil ( Ordinary ) , Providing, Supplying And Fixing Lt Cast Iron Pot Heads Suitable For 1.1 Kv Class Ug Cable Filled With Necessary Bitumen / Insulating Compound Complete With Terminals Clamps, Bolts, Nuts And Washers, Etc. With All Necessary Materials And Labour Tools And Equipment’S As Per Specifications, With Testing Of As Per Instructions Of Engineer / Assigned Officers Incharge Of Work.-3.5X10 Sqmm, Providing, Supplying And Fixing Lt Cast Iron Pot Heads Suitable For 1.1 Kv Class Ug Cable Filled With Necessary Bitumen / Insulating Compound Complete With Terminals Clamps, Bolts, Nuts And Washers, Etc. With All Necessary Materials And Labour Tools And Equipment’S As Per Specifications, With Testing Of As Per Instructions Of Engineer / Assigned Officers Incharge Of Work.-3.5 X 25 Sqmm, Supporting Clamps ( Two Pairs ) , Pvc Cable Locking Strips ( 2 Nos Per Length ) Heavy ( For Installation Of 152 Mtrs & Above ) Each Pair Weighing Not Less Than 4000 Grms Of 350Mmx60mmx10mm Size., Borewell Cap ( Including Bolts And Nuts ) Weighing Not Less Than 800 Gms., Earthing: Supplying And Fixing And Wiring Earth Electrode For Grounding Circuits Ic Cutouts And Other Equipment’S On The Meter Board In The Pit. The Pits Should Be Filled Up With Equal Proportion Of Salt And Charcoal 150Mm Around The Pipe To Complete Depth. The Connection From The Pipe To The Conduits Etc. Is To Established Through Gi Wire Of Sizes As Per Clause 7.3.3 Of Is 732 Using 12Mm Bolts, Nuts, Washers And Check Nuts, The Pipe Shall Have 16 Through Holes Of 12Mm Dia.