Supply, Installation, Testing And Commissioning Of Lighting System For Pass-B, Common Area Of Pass-A And Id Fan Of Electrostatic Precipitators Unit4, Ctpp, Rrvunl, Chhabra Supply, Installation, Testing And Commissioning Of Lighting System For Pass-B, Common Area Of Pass-A And Id Fan Of Electrostatic Precipitators Unit4, Ctpp, Rrvunl, Chhabra , Well Glass Led With Fixture 40 Watt , Led Flood Lights 100W , 4 Feet Long 20 Watt Led Tube Light With Aluminium Fixture , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130 / Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A / C / D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc / Ms Conduit / Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr , 1 X 2.5 Sq.Mm , 1 X 4.0 Sq.Mm , Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity ( B / C / D Tripping Characteristic As Per Type Of Load And Site Requirement ) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947- 2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheets, Minimum Electrical Operation 20, 000 Upto 20 A Rating And 10, 000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr , Single Pole Mcb , 6 A Rating , Double Pole Mcb , 20A Rating , Double Pole Mcb , 32A Rating , Four Pole Mcb , 63 A Rating , Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity ( B / C / D Tripping Characteristic As Per Type Of Load And Site Requirement ) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947- 2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheets, Minimum Electrical Operation 20, 000 Upto 20 A Rating And 10, 000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr , 63 A Rating Rccb Four Pole 100 / 300 Ma Sensitivity , Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity ( B / C / D Tripping Characteristic As Per Type Of Load And Site Requirement ) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947- 2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheets, Minimum Electrical Operation 20, 000 Upto 20 A Rating And 10, 000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr , 25.0 Sq.Mm Flat Ring Type ( Ac ) , 35.0 Sq.Mm Flat Ring Type ( Ac ) , 50.0 Sq.Mm Flat Ring Type ( Ac ) , Supplying And Making End Termination With Heavy Duty Copper Lugs ( Any Type ) Confirming To Is 8337 -1976 Duly Crimped With Crimping Tool, Pvc Tape Etc Of Following Size.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , Copper Lugs2.5 Sq.Mm , Copper Lugs4 Sq.Mm , P & F Of Industrial Plug And Socket Conforming To Iec 60309-1 / 2 Made Out Of Self Extinguishing Engineering Polymer / Polyamide, Nickel Plated Brass Sleeve And Pins, Socket With Shutter Including Making Connection Etc As Reqd. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 1 Ip -67 Panel Mounted Socket 63 A 5 Pin ( 3P+N+E ) , Providing & Fixing Of Recessed / Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed ) Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door ( For Double Door Db Only ) 100 Amp. Insulated Copper Bus Bar / Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar, Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr , Glazed Door ( Three Phase ) Ik-09 And Ip-43 With Metal End Box 12 Way , J. Poletubular Type With Clamp And Nut Bolts , Providing & Fixing Of Iso Certified Company Made Bolted Type / Din Type Hbc ( High Breaking Capacity ) Fuse Links Of 80 Ka Breaking Capacity, As Per Pwd Specification For Electrical Works Conforming To Is:13703 In The Existing Fuse Base, Fuse Switch Unit Etc. Of The Following Type And Rating. Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , 32 Amp. Cylindrical Fuse Link , 63 A Size 00Din ( Knife Type ) Type , 100 A Size 00Din ( Knife Type ) Type , 125 A Size 00Din ( Knife Type ) Type , Control Cable 4C X 2.5Sq.Mm Add Extra In Item No. 11.1 To 11.4 For Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. Up To 35 Sq.Mm Fixed With 25 Mm X 2 Mm Thick Suitable Length Red Oxide And Enamel Painted Ms Clamp And Base, Pvc Rawl Plug And Screws Of Sufficient Size With Spacing 0.6 Mtr. Between Clamps. , Metallic Flexible Conduit In Meters , Part-Iii: Brass Cable Glands Double Compression Medium Duty Cable Glands 16 Sq. Mm , Part-Iii: Brass Cable Glands Double Compression Medium Duty Cable Glands 35 Sq. Mm , Part-Iii: Brass Cable Glands Double Compression Medium Duty Cable Glands 50 Sq. Mm , Pvc Cable Junction Boxes Including Din Rail For Mcb , Connector For Cable Terminals Threaded Cable Gland Size:- 300Mm*200Mm*125Mm.