| 1 | Taking downand Material and labour for steel tubular swaged pole type 410 SP-55 (11metre long) with 300 mmx300mmx6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5M from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5M from ground level/coping, complete all as specified and directed. |
| 2 | Taking down burnt cable and Supply,fixing and testing of Aerial bunched cable (AB) HT 6.35/11 KV of size 3 core- X 95 sqmm+1-core X 70 sqmm with three power cores stranded compacted circular aluminium conductor screened with black extruded semiconducting compound, natural coloured XLPE insulated core screenedwith black extruded semi conducting compound and one layer of copper tape and covered with black extruded PVC( core identification by colour tape marking red, yellow and blue with colour tape placed longitudinally under the copper tape) and one bare messenger wire shall be stranded non compacted circular aluminium alloy conductor, all as specified and directed.Make:- Havells, Gloster, Polycab, Grandlay Note:- The following hardware fittings and accessories shall be used to install, erect and join the AB cable :- (i) Suspension clamp with eye hook (ii) Suspension fittings and corresponding eye hook(iii) Dead eye fittinngs(iv) Nylon Tie(v) connectorsNote: - Contractor has do all kind of tests for HT cable as per EI Rule before fixing on poles and cost of end jointing kitsshall not be paid separetly and cost of the same included in rate quoted. |
| 3 | Taking down old /unsv earthingand provision of new Earthing complete with galvanized steel earth plate electrode 600mm x600mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground leel, connecting to the Galvanised earthing lead strip 32x6mm size, by means of bolts, nuts, heck nuts and washers of galvanized iron andearth lead protected by provision of GI medium grade pipe 65mm bore incl provision of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt & charcoal filling, test point made out of 40mm x 8mm FI with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs, all as per electrical plate No 5 of SSR-1991 Part I and connected to earth test point, all as specified or indicated incl testing on completion. Note:-The required resistance of Earthing shall be 2 ohm or less than 2 ohm, If not fouund to the required resisstance, the contractor has to reorganised for required resistance andthe cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance. |
| 4 | Supply and fixing in replacementfemale contact spring loaded having brass contacts suitable for GOD 200A forworking pressure 11000 Volts, galvanised iron bolts, nuts and washers for fixing with post insulator or any other indicated situation,all as required at site or directed by Engr In charge. |
| 5 | Supply and fixing in replacement male contact with arching horn having brass contacts suitable for GOD 200A forworking pressure 11000 Volts, galvanised iron bolts, nuts and washers for fixing with post insulator or any other indicated situation,all as required at site or directed by Engr In charge. |
| 6 | Supply and fixing in replacement copper braided belt 400mm long with MS carriersuitable for GOD 200A forworking pressure 11000 Volts, galvanised iron bolts, nuts and washers for fixing all as required at site or directed by Engr In charge. |
| 7 | Supply and fixing in replacement of HT feeder pillar boxoutdoor type factory made weather and vermin proof made out from 3.15 mm sheet supported with legs all across the panel made of angle iron 50x50x5 mm of size 1.2 mtrx1 mtrx1 mtr with 3 Nos required lengthAluminium bus bar of size 40x10mm or 400 Amps for11 KV , 11 KV post Insulator 6 Nos duly drilled hole for HT Cable connection including front and rear side openable with locking arrangment suitable for 11 KV HT and provision for incoming and out going HT cable connection including painting with two coats of smoke grey synthetic enamels paint over a coat of red oxide primer complete and providing security fence XPM jally type of 2 mtr height from ground level square type all rounded 2.5 mtr length with 9nos angle iron of 25x25x5mm of hight 2.25mtr (2mtr above ground 0.25 mtr under ground) including necessary location gate of same XPM jally all as specified and directed . Note:- Feeder piller box shall be mounted on brick platform built in PCC not less then 60 cm above ground level with suitable PCC foundation rendering 15 mm in CM (1:6), applying two coats and cement base paints and XPM jally supported on 9 nos angle iron with concrete base. |
| 8 | Supply, laying, jointing and testing underground cables XLPE insulated screened PVC bedded galvanised steel strips armoured electric power cables (heavy duty) with aluminium conductor HT 11000 volts grade and 95 sqmm 3 core cross sectional area conforming to latest IS and ISI marked, complete all as specified and directed by Engr-in-charge.Make- Havells, Gloster, Grandlay Note:-(i) Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule. |
| 9 | Supply, laying, jointing and testing underground cables XLPE insulated screened PVC bedded galvanised steel strips armoured electric power cables (heavy duty) with aluminium conductor HT 11000 volts grade and 120 sqmm 3 core cross sectional area conforming to latest IS and ISI marked, complete all as specified and directed by Engr-in-charge. Make Havells, Gloster, Grandlay Note:-(i) Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule. |
| 10 | Supply and fixing cable jointing kit for 11 KVgrade AB cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for single core AB cable of size 50 sqmm to 95 sqmm, complete all as specified and as directed. |
| 11 | Material and labour in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to185 sqmmRaychem, Denson or equivalent |
| 12 | Material and labour in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm Raychem, Denson or equivalent |
| 13 | Material and labour in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm Raychem, Denson or equivalent |
| 14 | Scraping of old paint from thesteel tubular pole 11 mtr height with out removing accessories and preparationof surfaces for repainting.Repainting the pole with one coat of alternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint and repainting the remaining pole and iron parts i.e U clamps, channels etc above 1.5 mtr height by applying one coat of alumn paintall as required at site or directed. Make of paint Asian, Berger, Nerolac |
| 15 | Material and labour in replacement of Lightening arrestor station type, complete with all fittings, transmission class, discharge capacity HT 11 KV rupturing capacity 65KA suitable for complete all as specified and directed. Make :-BHEL,Jaipuria,Alstom |
| 16 | Material and labour forgalvanised cross arms, bracings, supports, clamps, angles, hellowbars square/round, flat irons etc and back plates fabricated in structural steel sections including nuts, bolts, washers, welding, bending, fabrication, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat one undre coat and one finishing coat of paint and including removing old unserviceable item, complete all as specified and directed. |
| 17 | Material and labour for Cement concrete infilling and mass concrete/ Coping of Poles and PCC for road crossings etc all as directed , type C-2, 1:3:6 (40 mm graded aggregate) complete all as specified and directedby Engr-in-Charge. |
| 18 | Material and labour for Cement concrete infilling and mass concrete/ Coping of Poles and PCC for road crossings etc all as directed , type B-1, 1:2:4 (20 mm graded aggregate) complete all as specified and directed by Engr-in-Charge. |
| 19 | M&L in replacement ofACSR conductor any size toover head lines , stretching properly to achieve proper sag including binding to insulators using GI/alumn binding wire all as required at site or directed by Engr In Charge. |
| 20 | Labour only for restringing of over head line ACSR of any size and upto 3 wires in a span with GI earth wire of 4 mm dia of span length 30 to 60 m to permissiable sag incl winding with Aluminium conductor and triming of branches of tree beside the span all as directed. |
| 21 | Suplying and fixing in replacement of Pin type, porcelin, vitreour, white, brown or green insulator, size 150mm height, 150mm dia for 11000 volts grade, including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, conforming to IS: 7321-1931, complete all as specified and as directed by Engr-in-Charge. |
| 22 | Suplying and fixing Disc type insulator, porcelain / Polymer, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green single assembly for tension with tension clamps for conductors working pressure 11000 /33000 volts grade, complete all as specified and directed. |
| 23 | Material and labour for replacement of Air break gang operated switch with 12 Nos insulators outdoor type, triple pole, mechanically operated, suitable for vertical installation, single break, provided with locking arrangement, consisting of MS Channel, HT post type insulator copper alloy, high pressure, assembly drop out fuses, operating rod 25mm dia GI pipe, medium grade for operating from 1.2 m above GL complete including drop out fuses conforming to IS rated voltage 11 KV and for current rating 200 Amp all as specified and directed.Make : BHEL, PACTIL OBLUM, ABB,Rashtriya |
| 24 | Material and labour for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmmcomplete all as specified and directed.Make: DENSON, M-SEAL, BIRLA 3M, RAYCHEM, CABSEAL |
| 25 | Material and labour for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmmcomplete all as specified and directed.Make: DENSON, M-SEAL, BIRLA 3M, RAYCHEM, CABSEAL |
| 26 | Taking out carefully unserviceable XLPE HT underground cable of size 95 Sqmm /3-Core to 120 Sqmm /3-Core from trenches / Pipes including taking out bricks, complete all as specified and as directed. (Serviceable Bricks obtained shall be cleaned and stacked properly for reuse) |
| 27 | Laying only XLPE insulated, PVC inner sheathed, armoured, HT underground cable of size 95 Sqmm / 3-core to 120 Sqmm/ 3-Corelaid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified and directed.Note:-(i) Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule. |
| 28 | Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5 mtr deep for foundations of poles/stays/cable etc not exc 10 Sqm area on plan and getting out in soft/loose soil, complete all as specified and as directed. |
| 29 | Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed. |
| 30 | Removing excavated material (soils) not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point, complete all as specified and as directed. |
| 31 | Supply and laying sub class \"B\" bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid. |
| 32 | Material and labour for sand cushioning in trenches including spreading and consolidation in layers of 8 cm thick before laying the cable & 15 cm thick after laying the cable and punned down to form a bed complete all as specified and directed. |