| 1 | Material and labour for servicing / cleaning to window type Air conditioner 1.5 Ton completewith air blower , Cleaning of Condenser / Eva porter Coil Units with Air Blower & then wet servicing of Condenser / Eva porter Coil Units with washing soda etc , Checking of complete wiring , tightening of loose wire connections with proper Lugs / Clips. Renewal of defective wiring & terminal connector , Proper setting of thermostat & otherElectrical / Refrigerant controls, cleaning of air filter , reinstallation & testing for proper functioning / cooling effect complete all as specified and directed. NOTE: The spare parts shall be measured and paid separately as supply only rates.Rate for fixing of spare parts under relevant item shall be included in this item. |
| 2 | All as peritem No 1.00here in before but for window type Air Conditioner 1 Ton and -ditto-. |
| 3 | All as peritem No 1.00here in before but for Window type Air Conditioner 2 Ton and -ditto-. |
| 4 | Supply only compressor seal unit of suitable capacity/model in the unit properly for 1.5 TR window type ACISI marked complete all as specified and directed. |
| 5 | All as per item No 4.00 here-in-before but 2 TRand -ditto-. |
| 6 | Supply only hermetic type compressor seal unit of suitable capacity/model for 1.5 TR window type ACISI marked complete all as specified and directed. |
| 7 | All as per item No 6.00 here-in-before but 2 TRand -ditto-. |
| 8 | Supply only suitable capacity/model condensing coil unit copper for window type AC 1.0 Ton capacityISI marked complete all as specified and directed. |
| 9 | All as per item No 8.00 here-in-before but 1.5 Tonand -ditto-. |
| 10 | All as per item No 8.00 here-in-before but 2 Tonand -ditto-. |
| 11 | Supply only blower motor including fan blade, capacitor complete suitable for window type AC 1.0 ton/1.5 ton/2.0 ton capacity 1/8 HP, 220 Volts, complete single phase, ISI marked all as specified and directed. |
| 12 | Supply only cooling coil unit for window type AC of any type ISI marked complete all as specified and directed. |
| 13 | Supply and fix in repairstarting capacitor 80/100 Mfd 230 V AC for window type AC 1.0 Ton/1.5 Ton/2.0 Ton capacity ISI marked complete all as specified and directed. |
| 14 | Supply and fix in repair running capacitor 36/45/50 MFD 230 V for window type AC 1.0 Ton/1.5 Ton/2.0 Ton capacity ISI marked complete all as specified and directed. |
| 15 | Supplyand fix in repair overload protection coil230 Volts for window type AC 1.0 Ton/1.5 Ton/2.0 Ton capacity ISI marked complete all as specified and directed. |
| 16 | Supplyand fix in repair Relay suitable for window type AC 1.0 Ton/1.5 Ton/2.0 Ton capacity ISI marked complete all as specified and directed. |
| 17 | Supplyand fix in repair potential relay for window type AC 1.0/1.5/2.0 Ton capacity ISI marked complete all as specified and directed. |
| 18 | Supplyand fix in repair thermostat suitable for window type AC 1.0 ton/1.5 ton/2.0 ton capacity ISI marked complete all as specified and directed. |
| 19 | Labour only for charging refrigerant gas M-22/R-22 in the system of window type AC of 1.0/1.5 ton capacity complete all as specified and directed. Note : The refrigerant gas M-22/R-22 shall be measured and paid separatelyas ‘supply gas only’ under respective items. |
| 20 | Supplyand fix in repair capillary tube and strainer for window type AC of 1.0 ton/1.5 ton/2.0 ton capacity complete all as specified and directed. |
| 21 | Supplyand fix in repair operation knob for window type AC 1.0 ton/1.5 ton/2.0 ton capacity ISI marked complete all as specified and directed. |
| 22 | Taking out complete unserviceable wiring for AC window type 1.0 ton/1.5 ton/2.0 ton capacity and rewiring with suitable size multi stranded copper cable including testing, checking etc complete all as specified and directed. |
| 23 | Supplyand fix in repair PVC air filter for window type AC of 1.0 ton/1.5 ton/2.0 ton capacity ISI marked complete all as specified and directed. |
| 24 | Supplyand fix in repair capacitor for blower motor suitable for window type AC 1.0 ton/1.5 ton/2.0 ton capacityISI marked complete all as specified and directed. |
| 25 | Supplyand fix in repair fan blade for blower motor suitable for window type AC 1.0 ton/1.5 ton/2.0 ton capacity complete all as specified and directed. |
| 26 | Supplyand fix in repair fan blade for window type AC of any capacity complete all as specified and directed. |
| 27 | Supplyand fix in repair front grill for window type AC 1.0 ton/1.5 ton/2.0 ton capacity complete all as specified and directed. |
| 28 | Supplyand fix in repair swinging/oscillation motor with louvers as per existing make for window type AC 1.0 ton/1.5 ton/2.0 ton capacity ISI marked complete all as specified and directed. |
| 29 | Supplyand fix in repair PCB for control unit for window type AC 1.5 ton /2.0 ton capacity as per existing make or ISI marked complete all as specified and directed. |
| 30 | Supplyand fix in repair bearing/bush for blower and fan motor of capacity 1.0/1.5/2.0 TR complete all as specified and directed. |
| 31 | Material and labour for servicing of split type Air conditioner 1.5 Ton / Tower Air conditioner 2 Ton cleaning of Split type ACindoor / outdoor unit completewith air blower , cleaning of Condenser / Eva porter Coil Units with air Blower & then wet servicing of CondenserCoil Units with washing soda etc , Checking of complete wiring , tightening of loose wire connections with proper Lugs / Clips. Renewal of defective wiring & terminal connector , Proper setting of thermostat & otherElectrical / Refrigerant controls, cleaning of air filter , reinstallation & testing for proper functioning / cooling effect complete all as specified and directed. |
| 32 | All as per item No 31.00 here in before but for Split type Air Conditioner 2.0 Ton / 3.9 Ton and -ditto-. |
| 33 | All as per item No 31.00 here in before but for Split type Air Conditioner 1.0 Ton and -ditto-. |
| 34 | Supply only new compressor seal unit of suitable capacity/model in the unit properly for 1.0 Ton split type ACISI marked complete all as specified and directed. |
| 35 | All as per item No 34.00 here-in-before but 1.5 Ton and -ditto-. |
| 36 | All as per item No 34.00 here-in-before but 2 Ton and -ditto-. |
| 37 | All as per item No 34.00 here-in-before but 3.9 Ton and -ditto-. |
| 38 | Supply only condensing coil unit for split type AC 1.0 Ton capacity all as specified and directed. |
| 39 | All as per item No 38.00 here-in-before but 1.5 Ton and -ditto-. |
| 40 | All as per item No 38.00 here-in-before but 2 Ton and -ditto-. |
| 41 | Labour only for charging refrigerant gas M-22/R-22/R-138/R-32/R-410A in the system of split AC of 1.0/1.5/2 ton capacity complete all as specifed and directed.Note : The refrigerant gas M-22/R-22 shall be measured and paid separately under respective items. |
| 42 | Supply and fix in repair capillary tube and strainer for split AC of 1.5 ton/2.0 ton capacity ISI marked complete all as specified and directed. |
| 43 | Supply and fix in repair cooling coil unit for split type AC of any type ISI marked complete all as specified and directed. |
| 44 | Supply and fix in repair starting capacitor 80/100 Mfd 230 Volts AC for split type AC 1.0 / 1.5 / 2.0 ton capacity ISI marked complete all as specified and directed. |
| 45 | Supply and fix in repair running capacitor 36/45/50 Mfd 230 Volts for split type AC 1.0 / 1.5 / 2.0 ton capacity ISI marked complete all as specified and directed. |
| 46 | Supply and fix in repair overload protection coil230 Volts AC for split type AC 1.0 / 1.5 / 2.0 ton capacities ISI marked complete all as specified and directed. |
| 47 | Supply and fix in repair relay suitable for split type AC 1.0 / 1.5 / 2.0 ton capacity ISI marked complete all as specified and directed. |
| 48 | Supply and fix in repair copper pipe 5/8\" / 1/2\" / 3/8\" / 1/4\" dia (as per existing one) for connection to indoor and out door unit, ISI marked complete all as specified and directed. |
| 49 | Supply and fix in repair PVC insulated PVC sheathed 1.5 Sqmm, 3 core copper cable 1100 Voltscomplete all as specified and directed. |
| 50 | Supply and fix in repair PVC insulated PVC sheathed 2.0 Sqmm, 3 core copper cable 1100 Voltscomplete all as specified and directed. |
| 51 | Supply and fix in repair PVC insulated PVC sheathed 4.0 Sqmm, 3 core copper cable 1100 Voltscomplete all as specified and directed. |
| 52 | Supply and fix in repair swinging motor with louvers as per existingswinging motor with louvers, ISI marked complete all as specified and directed. |
| 53 | Supply and fix in repair blower motor including fan blade, capacitor complete (indoor unit/out door unit) for split type AC 1.5 ton / 2.0 ton capacity 220 volts, single phase ISI marked complete all as specified and directed. |
| 54 | Supply and fix in repair fan blade for blower motor suitable for split AC 1.5 ton / 2.0 ton capacity complete all as specified and directed. |
| 55 | Supply and fix in repair fan blade for outdoor unit of split type AC of any capacity complete all as specified and directed. |
| 56 | Supply and fix in repair LCD / LED display unit for split type AC 1.5 / 2.0 ton capacityISI marked complete all as specified and directed. |
| 57 | Supply and fix in repair PVC air filter for AC split type 1.5 / 2.0 ton capacity complete all as specified and directed. |
| 58 | Supply and fix in repair PCB for control unit for split type AC 1.5 / 2.0 ton capacity as per existing make of ISI marked complete all as specified and directed. |
| 59 | Supply and fix in repair bearing/bush for blower and fan motor of capacity 1.0/1.5/2.0 Ton complete all as specified and directed. |
| 60 | Material and labour for dismantling of storage type water cooler of 80ltr capacity in various location, shifting to MES Yard for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet by welding/brazing with suitable new sheet metal) by spraying enamel paint and marking/sticking a stickermentioning the MES No and reassembling, testing, checking and shifted to existing location, fixing the same by nut, bolt, angle iron structure and masonry work complete all asspecified directed.NOTE: The spare parts shall be measured & paid separately as supply only rates.Rates for fixing of spares parts under relevant item shall be included in this item. |
| 61 | Supply only compressor sealed unit of existing model in the unit properly for storage type water cooler of 80 ltr capacity ISI marked complete all as specified and directed. |
| 62 | Supply only blower motor including fan blade, capacitor complete suitable for 80 ltrs capacity, 220 volts, single phase ISI marked complete all as specified and directed. |
| 63 | Material and labour for servicing of water cooler, cleaning of water cooler 40/80 Ltrscomplete with blower, cleaning of condenser coil by blower and the wet servicing of condenser of coil with washing soda etc. Checking of complete wiring , tightening of loose wire connections with proper Lugs / clips. Renewal of defective wiring and connector terminal , proper setting of the thermostat and other electrical / Refrigerant controls and refixing the water cooler at place & testing for proper functioning / cooling effect complete for the following: |
| 64 | Labour only for charging refrigerant gas M-22/R-22 in the system of water cooler of any capacity all as directed. Note : The refrigerant gas M-22/R-22 shall be measured and paid separately as supply only. |
| 65 | Supply and fix in repair capillary tube and strainer for storage type water cooler of any capacity ISI marked complete all as specified and directed. |
| 66 | Supply and fix in repair overload protection coil 230 volts for water cooler of any capacity ISI marked complete all as specified and directed. |
| 67 | Supply and fix in repair relay suitable for water cooler of any capacity ISI marked complete all as specified and directed. |
| 68 | Supply and fix in repair thermostat suitable for water cooler of any capacity ISI marked complete all as specified and directed. |
| 69 | Supply and fix in repair running capacitor 40/50/60 Mfd suitable for water cooler of capacity 80/150 ltrs ISI marked complete all as specified and directed. |
| 70 | Supply and fix in repair starting capacitor 80/100 Mfd 230 volts AC for water cooler capacity 80 / 150 ltrs ISI marked complete all as specified and directed. |
| 71 | Supply and fix in repair capacitor 4/6/10 Mfd 230 volts, single phase AC for blower motor of water cooler ISI marked complete all as specified and directed. |
| 72 | Supply and fix in repair push type water tap made of CP brass suitable for water cooler capacity 80/150 ltrs capacity complete all as specified and directed. |
| 73 | Supply and fix in repair 600 mm long PVC connector complete all as specified and directed. |
| 74 | Supply and fix in repair CP angular stop cock,15mm dia, with wall flange complete all as specified and directed. |
| 75 | Supply and fix in repair CP bib cock, 15mm dia, with wall flange complete all as specified and directed. |
| 76 | Supply and fix in repair fan blade for water cooler of any capacity complete all as specified and directed. |
| 77 | Taking down complete unserviceable internal wiring of, water cooler, refrigerator of any capacity and rewiring the same with 2.5 Sqmm size multi stranded copper cable including testing checking etc complete all as specified and directed. |
| 78 | Supply and fix in repair drain tray made out of stainless steel for water cooler of any capacity complete all as specified and directed. |
| 79 | Supply and fix in repair head cover gasket for water cooler of any capacity complete all as specified and directed. |
| 80 | Supply and fix in repair drain pipe /water pipe flexible type 20 mm of dia for water cooler/Split/Winwod type AC of any capacity complete all as specified and directed. |
| 81 | Material and labour for dismantling of storage type refrigerator of any capacity in various location, shifting it to MES yard for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet by welding/brazing with suitable new sheet metal) by spraying enamel paintand marking/sticker mentioning the MES No,reassembling, testing, checking and shifted to existing location including masonry work complete all as specified and directed. NOTE: The spare parts shall be measured and paid separately as supply only rate.Rates for fixing of spare partsshalldeemed to beincluded in this item. |
| 82 | Supply only compressor seal unit of suitable capacity / model in the unit properly for domestic refrigerator of any type ISI marked complete all as specified and directed. |
| 83 | Material and labour for charging refrigerant gas 134A/HYDRO CARBON in the system of domestic refrigerator of any type complete all as specified and directed.Note : Refrigerant gas 134A/HYDRO CARBON shall be measured and paid separately. |
| 84 | Suplly and fix in repair capillary tube and stainer for any type and capacity of domestic refrigerator ISI marked complete all as specified and directed. |
| 85 | Suplly and fix in repair cooling coil unit for domestic refrigerator of any type ISI marked complete all as specified and directed. |
| 86 | Suplly and fix in repair timer of existing type for domestic refrigerator ISI marked complete all as specified and directed. |
| 87 | Suplly and fix in repair relay for domestic refrigerator of any type complete all as specified and directed. |
| 88 | Suplly and fix in repair thermostat for domestic refrigerator of any type ISI marked complete all as specified and directed. |
| 89 | Taking out complete unserviceable wiring for domestic refrigerator of any type and rewiring with suitable size multi stranded copper cable including testing , checking etc complete all as specified and directed. |
| 90 | Suplly and fix in repair CP angular valve of size 1/2\" suitable for split type AC complete all as specified and directed. |
| 91 | Suplly and fix in repair CP angular valve of size ¼\" suitable for split type AC complete all as specified and directed. |
| 92 | Suplly and fix in repair CP angular valve of size 5/8\" suitable for split type AC complete all as specified and directed. |
| 93 | Suplly and fix industrial socket15 Amp complete all as specified and directed. |
| 94 | Supply and fixRemote control for window type AC of Samsung make of 1.5 TR/2 TR complete all as specified and directed. |
| 95 | Supply and FixRemote control for split type AC of LGmake of 1.5 TR/2 TR complete all as specified and directed. |
| 96 | Removing the unserviceable voltage stablizer of 1KVA capacity, 1 Phase, 230V, 50Hz from position , open the outer covers, remove the burntout windings from the transformer , rewinding the superanamaled copper windings wire , insulate properly , setting/ testing of buck / boost relay, assemble back & fixing in its original position including testing for proper functioning complete all as specified and directed. |
| 97 | All as per item No 96.00 here-in-before but 2KVA capacity, 1 Phase, 230V, 50Hz and -ditto-. |
| 98 | All as per item No 96.00 here-in-before but 5KVA capacity, 1 Phase, 230V, 50Hz and -ditto-. |
| 99 | Repair / Maintenance of voltage stablizer of 1 to 5 KVA capacity from its position, open the outer covers, overhauling the complete unit by cleaning & replacement of minor spares such as fuse, diodes, carbon bushes, internal electric wiring and electronic accessories complete all as specified and directed.Note: Spares such as Voltmeter, Ammeter, MCB, toggle switch, PCB board and relays shall be measured and paid seperately under respective items as supply only. |
| 100 | Supply only voltmeter single phase up to 250 Volt range complete all as specified and directed. |
| 101 | Supply only Ammeter single phase upto 40 Amps range complete all as specified and directed. |
| 102 | Supply only over load protection relay complete all as specified and directed. |
| 103 | Supply only PCB for capacity 1KV to 5KV complete all as specified and directed. |
| 104 | Supply only switch knob for up & down complete all as specified and directed. |
| 105 | Material and labour for shifting of serviceable window type AC of any capacity from one location to another location complete all as specified and directed. Note : Cost for spares such as fast nut and stand shall be included in quoted rates. |
| 106 | Material and labour for shifting of serviceable split type AC of any capacity from one location to another location complete all as specified and directed. Note : Cost for spares such as fast nut and stand shall be included in quoted rates. |
| 107 | Supply and fix in repair split AC mounting bracket stand uitable for 1.5 Ton AC complete all as specified and directed. |
| 108 | Material and labour for repair to PCB control unit of windowtype AC 1.0/1.5/2.0 TRduly servicing and replacing integrated circuit and other devices and refixing the same complete all as specified and directed |
| 109 | Material and labour for repair to PCB control unit of splittype AC 1.0/1.5/2.0 TRduly servicing and replacing integrated circuit and other devices and refixing the same complete all as specified and directed |
| 110 | Material and labour for providing black foam insulation of adequate thickness over copper tubing of any size complete all as specified and directed. |
| 111 | Supply and fix in repair refrigerant charging pipe of high quality rubber, good corrosion resistance including provision ofdouble pressure gauge pipe of length 150cm for refrigerant filling of air conditioning system complete all as specified and directed. |
| 112 | Supply only refrigerant gas M-22/R-22/R-32/R-410Acomplete all as specified and directed. |
| 113 | Supply only refrigerant gas 134A complete all as specified and directed. |
| 114 | Supply only refrigerant gas HYDRO CARBONcomplete all as specified and directed. |
| 115 | Supply only LPG cane gas of 900 ml capacity for welding and brazing including welding stick of condensing coil unit complete all as specified and as directed. |