}

Medical Services For 450 Beds Hospital At Svb Civil Hospital At Silvassa ( 2Nd Call ) .- 1 Central Sterile Supply Department Double Washer Disinfector - (Minimum 250 LT / Minimum 12 DIN)capacity it should have capacity of minimum 250L and The usable, Dadra And Nagar Haveli-Dadra And Nagar Haveli

Government Departments has published Medical Services For 450 Beds Hospital At Svb Civil Hospital At Silvassa ( 2Nd Call ) .- 1 Central Sterile Supply Department Double Washer Disinfector - (Minimum 250 LT / Minimum 12 DIN)capacity it should have capacity of minimum 250L and The usable. Submission Date for this Tender is 09-09-2022. Road Repair Tenders in Dadra And Nagar Haveli Dadra And Nagar Haveli. Bidders can get complete Tender details and download the document.




Tender Notice

33726176
Corrigendum : Medical Services For 450 Beds Hospital At Svb Civil Hospital At Silvassa ( 2Nd Call ) .- 1 Central Sterile Supply Department Double Washer Disinfector - (Minimum 250 LT / Minimum 12 DIN)capacity it should have capacity of minimum 250L and The usable
Open Tender
Indian
Dadra And Nagar Haveli
Dadra And Nagar Haveli
09-09-2022

Tender Details

Medical Services For 450 Beds Hospital At Svb Civil Hospital At Silvassa ( 2Nd Call ) .- 1 Central Sterile Supply Department Double Washer Disinfector - (Minimum 250 LT / Minimum 12 DIN)capacity it should have capacity of minimum 250L and The usable washing chamber volume should not be less than 250L, The dryer blower flow rate should be more than 210 m3/hr and having a temperature range between 50 to 100 degrees Celsius.European CE Certified by Four Digit Notified - As per Technical Specifications of the Tender 2 Double Door Steam Sterilizers minimum 700 Liters/10 STU capacity European CE Certified by Four Digit Notified Body, Pressure Equipment Directive 97/23/EC and EN 285/EN 554 Standards. - As per Detailed Technical Specifications of the Tender, Including Inside Cart (Platform) for Sterilizer for Loading (02 nos)- As per Technical Specifications of the Tender. Including Transport Trolley for Steriliser (04 nos) - As per Technical Specifications of the Tender 3 Stainless Steel Baskets 1 STE- As per Technical Specifications of the Tender 4 Ultrasonic Cleaner (Minimum 40L), Operating 40 Hz,US FDA certificate / European CECertified 5 Rotary Heat Sealer with Roller Front Table European DoC, and DIN 58953-7:2008, ISO 11607-2 and EN 868-5 -As per Technical Specifications of the Tender 6 Double Door Plasma Sterilizer: it should be double-door low temperature plasma sterilizer with a minimum 130 liters chamber volume. The chamber should have usable volume of minimum 100 Liters. European CE certified with Four Digit Notified Body, 48-60% H2O2 concentration - As per Technical Specfications of the Tender 7 TABLE TOP STEAM STERILIZER ,Minimum 23L Capacity, 5 Trays- As per Technical Specfications of the Tender 8 DRYING CABINET , Minimum 300 L capacity- As per Technical Specfications of the Tender 9 SPRAY GUN RINSER - As per Technical Specfications of the Tender 10 GAUZE CUTTING MACHINE WITH SS TABLE - As per Technical Specfications of the Tender 11 STAINLESS STEEL PASS BOX, DOUBLE DOOR- As per Technical Specfications of the Tender 12 CLOSED TRANSPORT TROLLEY - As per Technical Specfications of the Tender 13 MANUAL TROLLEY WASH UNIT- As per Technical Specfications of the Tender 14 STERILE TAPE DISPENSER - As per Technical Specfications of the Tender 15 Medical Gas Pipe line SystemSITC of Medical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. All copper pipes should be medical grade degreased & delivered capped at both ends. The pipes should be accompanied with manufacturers test certificate for the physical properties & chemical composition. Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified. Valid BSI kite Mark and CE certificated must be submitted.copper pipes size as mentioned below:108mm OD X 1.5mm thick,As per tendertechnical specificationMedical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 Printed with “OXY”, “MED” or OXY/MED and/or as per latest certification standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. 16 SITC of Medical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. All copper pipes should be medical grade degreased & delivered capped at both ends. The pipes should be accompanied with manufacturers test certificate for the physical properties & chemical composition. Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified. Valid BSI kite Mark and CE certificated must be submitted. As per technical specification.copper pipes size as mentioned below:76mm OD X 1.5mm thick,As pertender technical specificationMedical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 Printed with “OXY”, “MED” or OXY/MED and/or as per latest certification standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. 17 SITC of Medical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. All copper pipes should be medical grade degreased & delivered capped at both ends. The pipes should be accompanied with manufacturers test certificate for the physical properties & chemical composition. Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified. Valid BSI kite Mark and CE certificated must be submitted. copper pipes size as mentioned below:54 mm OD X 1.2mm thick,As pertender technical specification. Medical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 Printed with “OXY”, “MED” or OXY/MED and/or as per latest certification standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. 18 SITC of Medical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. All copper pipes should be medical grade degreased & delivered capped at both ends. The pipes should be accompanied with manufacturers test certificate for the physical properties & chemical composition. Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified. Valid BSI kite Mark and CE certificated must be submitted. As per technical specification.copper pipes size as mentioned below:42 mm OD X 1.2mm thick,As per tender technical specification. Medical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 Printed with “OXY”, “MED” or OXY/MED and/or as per latest certification standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. 19 SITC of Medical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. All copper pipes should be medical grade degreased & delivered capped at both ends. The pipes should be accompanied with manufacturers test certificate for the physical properties & chemical composition. Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified. Valid BSI kite Mark and CE certificated must be submitted. copper pipes size as mentioned below:28 mm OD X 1 mm thick, As per tender technicalspecification.Medical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 Printed with “OXY”, “MED” or OXY/MED and/or as per latest certification standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. 20 SITC of Medical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. All copper pipes should be medical grade degreased & delivered capped at both ends. The pipes should be accompanied with manufacturers test certificate for the physical properties & chemical composition. Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified. Valid BSI kite Mark and CE certificated must be submitted. copper pipes size as mentioned below:22 mm OD X 1 mm thick, As pertender technical specification.Medical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 Printed with “OXY”, “MED” or OXY/MED and/or as per latest certification standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. 21 SITC of Medical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. All copper pipes should be medical grade degreased & delivered capped at both ends. The pipes should be accompanied with manufacturers test certificate for the physical properties & chemical composition. Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified. Valid BSI kite Mark and CE certificated must be submitted. copper pipes size as mentioned below:15 mm OD X 1 mm thick, As per technical specification. Medical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 Printed with “OXY”, “MED” or OXY/MED and/or as per latest certification standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. 22 SITC of Medical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. All copper pipes should be medical grade degreased & delivered capped at both ends. The pipes should be accompanied with manufacturers test certificate for the physical properties & chemical composition. Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified. Valid BSI kite Mark and CE certificated must be submitted. copper pipes size as mentioned below:12 mm OD X 1 mm thick, As per technical specification. Medical Grade BSI Kite Mark & CE certified Copper pipe should be as per fully comply and meets withstandard BS: EN 13348:2016/ ASTM B819 Printed with “OXY”, “MED” or OXY/MED and/or as per latest certification standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe conforming to the standard. 23 SITC of Gas Outlets Points/Terminal Units It should complies with HTM 02-01/NFPA 99C/DIN/EN/ISO-7396-1 standards. It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listed. Bidder must submit copy ofUL Listed or ETL Listed Certificate or US FDA Certificate or notified body CE certificate as per medical devices regulations with four digit number on each item. Terminal units shall have gas indexing geometry. Other gas specific indexing geometries are not acceptable. Terminal unit front fascia should be metal and it should be hundred percent metal. Gas specific components comprising the terminal unit second fix shall be manufactured from die-cast zinc alloy or similar hard wearing metal. Plastic components are not acceptable. Terminal units socket castings shall be permanently coated with a low friction fluoropolymer for maximum reliability and service life. The terminal unit socket die-casting shall incorporate a gas indexing pin to overcome the risk of loosening due to rough handling or abuse. The second fix socket shall incorporate a sheer-plane to safeguard the first fix and pipeline in the event of accidental damage or bed jacking. Gas specific components shall incorporate the gas identity marking permanently stamped or cast into the component surface. The first fix shall be all metal construction, with a brass base block and copper stub pipe.The first fix shall incorporate an integral check valve to enable servicing of the second fix and valve seals without isolation of the gas supply.MedicalOxygen,As pertender technical specification. 24 Nitrous Oxide as per (above Item. No.9) Specification &tender technical specification. 25 Medical Air 4 Baras per (above Item. No.9) Specification &tender technical specification. 26 Surgical Air 7 Baras per (above Item. No.9) Specification &tender technical specification. 27 Vacuum as per (above Item. No.9) Specification & tender technical specification. 28 AGSSas per (above Item. No.9) Specification &tender technical specification. 29 CO2 as per (above Item. No.9) Specification & tender technical specification. 30 SITC of matching Probe / Adaptor With one end suitable for Hose & other end suitable for terminal units as per technical specifications for Oxygen for Nitrous Oxide , for Compressed Air ( 4 Bar ), For Compressed Air (7 Bar) , For Vacuum, For AGSS/WAG .Fully complies toHTM02-01/NFPA99 /EN/DIN/ISO7396-1It should be US FDA/ European CE with four digit notifiedbody number American ETL/Americal UL Listed. qualitymanagementsystemduly certifiedwithcopy of certificate of country of originNFPA it must be UL listed as per NFPA medical gas categorisation One end of matching probes shall be suitable for Medical Gas Outlet point & other end shall be suitable for hose. Suitable for Oxygen, CO2, Nitrous Oxide, Compressed air 4 bar, compressed air 7 bar, DISS connection, vacuum. Medical Oxygen, As per technical specification. 31 Nitrous Oxide as per (above Item. No.16) Specification & tendertechnical specification. 32 Medical Air 4 Baras per (above Item. No.16) Specification &tendertechnical specification. 33 Surgical Air 7 Baras per (above Item. No.16) Specification &tendertechnical specification. 34 Vacuum as per (above Item. No.16) Specification & tendertechnical specification. 35 AGSSas per (above Item. No.16) Specification & tendertechnical specification. 36 CO2 as per (above Item. No.16) Specification & tendertechnical specification. 37 SITC of The MedicalGas AreaAlarms should be digital and capable of monitoring up to 6/7 medical gas servicesby means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum.. It Should Complies with HTM 02-01 / NFPA 99/EN/DIN/ ISO 7396-1 Standards.It should be US FDA/ European CE with four digit notifiedbody number American ETL/Americal UL Listed.A test certificate shall be provided with each system detailing the results of the factory tests (EMC Test passed. Copy of certificate must be submitted.).The cover, backbox and bezelshall be polyester powder. A single tamperproof fastener shall be used to gain access to the hinged door. The hinge shall operate through a minimum of 120° to provide adequate access. Each gas service shall be on the color LCD touchscreen display to show ‘the actual pressure readings in real time. Failure indicators shall be displayed by flashing lights and normal indications shall be steady. The area alarm should have a digital display of pressures.An audible warning should sound simultaneously with any failure indication and a mute facility should be provided. it should be ready to use with BMS system. 2 Gas (Oxygen Vacuum),As per tendertechnical specification. Bidder Shall offer Area Alarm + Area Valve combined unit but they have to match the BOQ quantities of higher number for alarm/valve whichever quantities will be higher. The Medical Gas Alarm should include Area Valve for Each Gas Pipeline. 38 3 gas ( Oxygen Vacuum , MA4)as per (above Item. No.37) Specification &technical specification. 39 4 gas ( Oxygen , Vacuum , MA4 , N20)as per (above Item. No.37) Specification &technical specification. 40 6 gas ( O2, VAC , MA4 , SA7 CO2, N20)as per (above Item. No.37) Specification &technical specification 41 SITC of Master Alarm panel 6 services (Oxygen, N2O, MA4 Air, SA7 Air, CO2 and Vacuum)It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listed. Complies with HTM 02-01 / NFPA 99C/EN/DIN/ ISO 7396-1 Standards. A test certificate shall be provided with each system detailing the results of the factory tests (EMC Test passed. Copy of certificate must be submitted). Depending on the alarm priority, a visual and audible alarm should be initiated to indicate an alarm condition. The display should be in the form of light indicator or flasher on display, for each of the labelled alarm condition as listed below. It must be possible to freely configure the alarm priorities. Each display of alarm condition must be accompanied with audible alarm as well. There must be facility to mute the audible alarm for short pre-fixed durations by pressing of alarm silence / mute button. There must be facility to test all the display lamps on the alarm panel. All the electronic circuits should be mounted inside the cover frame. .) The cover, backbox and bezel (if required) shall be polyester powder. A single tamperproof fastener shall be used to gain access to the hinged door. The hinge shall operate through a minimum of 120° to provide adequate access. Each gas service shall be on the colorLCD touchscreen display to show ‘the actual pressure readings in real time. Failure indicators shall be displayed by flashing lights and normal indications shall be steady. As per Specification. 42 SITC of Fully Automatic Oxygen Control System 2000 LPM or more It should comply with HTM 02-01/NFPA 99C/DIN/EN/ISO-7396-1 standards. It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listed. A test certificate shall be provided with each system detailing the results of the factory tests (EMC Test passed. Copy of certificate must be submitted).The rated flow capacity of the automatic control panel (with one of the second stage regulator in operation) should 2000 LPM or more at 4.2 bar line distribution pressure to meet flow rate capacity. There shall be two separate stages of pressure regulation to enable high peak flow rates without a reduction in line pressure. The system shall be duplexed such that any single component failure will not affect the integrity of the medical gas supply. Allregulatorsshallbeprotected against overpressurizationbyreliefvalveswhich shall be pre piped into the manifold exhaust line stub to enable gas to be vented out of manifoldroom. A Digital touchscreen panel display’s pressure in each cylinder bank left and right, the outlet pressure shall be permanently shown. It should have Digital colorful display. It should have Integrated & protected test point. Central regulators panel with cylinder headers each side. It should have headers which shall be complete with gas specific cylinder tailpipes. Pre-wired for alarm connection to BMS outputs. All components degreased for oxygen use .Average gas consumption indication (for not liquefied gases). Remaining gas volume indication (for not liquefied gases). It should have general maintenance indicator. It should have Pressure transmitters monitor both banks of cylinders. The system should have a universal input and work in a wide power range: AC 90 to 264 Volts 50/60 Hz. The manifold control system shall be powered by an extra low voltage on board supply. A separate power supply board should be foreseen. The controller shall include alarm connections with a wire monitoring technology and sets of BMS connections for both normally open and normally closed operation. As per technical Specification. 43 SITC of Oxygen Manifold (2x20) as per HTM 02-01/NFPA 99C/DIN/EN/ISO-7396-1 standards. It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listed. Cylinder racks shall be designed to securely support cylinders of varying diameters using chains.Manifold header racks shall be high-pressure rated >250bar with gas specific tailpipe connections. High pressurecollectingpipes made up of annealedcupronickelcopper pipes with integratednon-returnvalvesforconnectionof gas cylindersonthe leftandright cylinder bank side each The high-pressure collectingpipeshouldbe modularin naturewithbox nutand connector allowing any extension and combinations required in future. All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders. As per Technical Specification. 44 SITC of Emergency Oxygen Supply System (2X10) as perHTM02-01/NFPA99 /EN/DIN/ISO7396-1Standard and technical specifications. It should be US FDA/ European CE with four digit notifiedbody number American ETL/Americal UL Listed.The ESM shall be designed and certified for use with oxygen at 300 bar and 60°C. The ESM shall provide a backup supply of medical gas from a high pressure cylinder bank via a suitable arrangement of pressure regulators, providing a constant downstream nominal pipeline gauge pressure of 400 kPa. Emergency Standby Manifolds (ESM) comprise a pressure regulator, manifold header & rack, tailpipes, a cylinder contents pressure switch, an isolation valve and a pressure relief valve.Manifold header racks shall be high-pressure rated >250bar with gas specific tailpipe connections. High pressurecollectingpipes made up of annealedcupronickelcopper pipes with integratednon-returnvalvesforconnectionof gas cylindersonthe leftandright cylinder bank side each The high-pressure collectingpipeshouldbe modularin naturewithbox nutand connector allowing any extension and combinations required in future. All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders. As per Technical Specification. 45 SITC of Oxygen Flow meter with Humidifier Bottle as perHTM02-01/NFPA99 /EN/DIN/ISO7396-1Standard, Fully complies to HTM02-01 BSEN 7396 shall, be CE marked as class IIb medical device 93/42/EEC. The oxygen flow meter must be manufactured under ISO-9001-2015. ISO 13485:2016, EN ISO 13485:2016 quality management system. Flow meter shall be manufactured to EN 13220:1999 and ISO 15002:2008 and technical specifications.Fully complies to HTM02-01 BSEN 7396 shall, be CE marked as class IIb medical device 93/42/EEC 1.4 Oxygen Flow meter with Humidifier BottleA) Control within a range of 0-15 LPMIt should complies with HTM 02-01/NFPA- 99/DIN/EN/ISO-7396-1 standard. Back Pressure Compensated flow meter for accurate gas flow measurement with following features:A) Control within a range of 0-15 LPM.B) It should meet strict precision and durability standard.C) The flow meter body should be made of brass chrome plated materials.D) The knob was tested under pressurized working conditions during more than 10,000 cycles without showing any leakage after closingE) The flow tube and shroud components should be made of clear, impact resistant polycarbonate.F) Flow tube should have large and expanded 0-15 LPM range for improved readability at low flows.G) Inlet filter of stainless steel wire mesh to prevent entry of foreign particlesH) Thehumidifier bottle 250cc is made of unbreakable & reusable polycarbonate /polysulfone material autoclavable at 121 degree centigrade.I) Humidifier Bottle should be covered under warranty & CMC.J) It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listed.The flow meters should be with inlet pressure 50-60psi. (4.5 bar). The closing of the knob should be without any leakage. Copy of bill of lading and certificate of country of origin duly stamped and signed by chamber of commerce to be submitted at the time of supply 46 SITC of OxygenHigh Flow meter with Humidifier Bottle as per HTM02-01/NFPA99 /EN/DIN/ISO7396-1Standard, Fully complies to HTM02-01 BSEN 7396 shall, be CE marked as class IIb medical device 93/42/EEC. The oxygen flow meter must be manufactured under ISO-9001-2015. ISO 13485:2016, EN ISO 13485:2016 quality management system. Flow meter shall be manufactured to EN 13220:1999 and ISO 15002:2008 and technical specifications.Fully complies to HTM02-01 BSEN 7396 shall, be CE marked as class IIb medical device 93/42/EEC.Oxygen High flow meter with humidifier bottle (0-70LPM)It should complies with HTM 02-01/NFPA- 99/DIN/EN/ISO-7396-1 standard. Back Pressure Compensated flow meter for accurate gas flow measurement with following features:A) Control within a range of 0-70 LPM.B) It should meet strict precision and durability standard.C) The flow meter body should be made of brass chrome plated materials.D) The flow tube and shroud components should be made of clear, impact resistant polycarbonate.E) Flow tube should have large and expanded 0-70 LPM range for improved readability at low flows.F) The knob was tested under pressurized working conditions during more than 10,000 cycles without showing any leakage after closingG) Inlet filter of stainless steel wire mesh to prevent entry of foreign particlesH) Thehumidifier bottle is made of unbreakable & reusable polycarbonate /polysulfone material autoclavable at 121 degree centigrade.I) Humidifier Bottle should be covered under warranty & CMC.J) It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listed.Copy of bill of lading and certificate of country of origin duly stamped and signed by chamber of commerce to be submitted at the time of supply , As per technical specification 47 SITC of Fully Automatic Manifold Control Panel for NitrousOxide 500 LPM or moreas per HTM02-01/NFPA99 /EN/DIN/ISO7396-1 Standard.It should be US FDA/ European CE with four digit notifiedbody number American ETL/Americal UL Listed. A test certificate shall be provided with each system detailing the results of the factory tests (EMC Test passed, Adiabatic test passed. Copy of certificate must be submitted). Pressure regulators and line pressure regulators must be compliant to EN ISO 10524-2:2005,2006 Fully automatic control panel must ensure complete seamless operationshouldbe designedandcertifiedforusewithNitrous oxide at200 bar +10° to +60°C degree Celsius. The rated flow capacityof the automaticcontrolpanel (withone of the second stage regulator in operation) should be 2 nos. of 500 LPM at 4.2Bar line distributionpressureto meetflowrate capacity and technical specifications. supply line pressure. All regulators, piping and control switching equipment shall be cleaned for nitrous oxide service. Control panel shall provide a Flow Capacity of over 500 litres/min. It should have Digitalcolorful display. It should have Integrated & protected test point. Central regulators panel with cylinder headers each side. It should have headers which shall be complete with gas specific cylinder tailpipes. Pre-wired for alarm connection to BMS outputs. All components degreased for oxygen use .Average gas consumption indication (for not liquefied gases). Remaining gas volume indication (for not liquefied gases). It should have general maintenance indicator. It should have Pressure transmitters monitor both banks of cylinders. The system should have a universal input and work in a wide power range: AC 90 to 264 Volts 50/60 Hz. The manifold control system shall be powered by an extra low voltage on board supply. A separate power supply board should be foreseen. The controller shall include alarm connections with a wire monitoring technology and sets of BMS connections for both normally open and normally closed operation.As per technical specification. 48 SITC of Nitrous Oxide Manifold (2x 6 ) as per HTM02-01/NFPA99 /EN/DIN/ISO7396-1Standard and technical specifications.. It should be US FDA/ European CE with four digit notifiedbody number American ETL/Americal UL Listed.Fully complies to HTM02-01 BSEN 7396 shall, be CE marked as class IIb medical device 93/42/EEC with four digit notified number specified. All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders. As per technical Specification 49 SITC of Emergency Nitrous Oxide Supply System (2x2) as per fully complies HTM02-01/NFPA99 /EN/DIN/ISO7396-1Standard and technical specifications.It should be US FDA/ European CE with four digit notifiedbody number American ETL/Americal UL Listed. All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders. As per technical Specification 50 SITC of Fully Automatic Manifold Control Panel for CO2500 LPMas per HTM02-01/NFPA99 /EN/DIN/ISO7396-1 Standard. It should be US FDA/ European CE with four digit notifiedbody number American ETL/Americal UL Listed.A test certificate shall be provided with each system detailing the results of the factory tests (EMC Test passed, Adiabatic test passed. Copy of certificate must be submitted). Pressure regulators and line pressure regulators must be compliant to EN ISO 10524-2:2005,2006 Fully automatic control panel must ensure complete seamless operationshouldbe designedandcertifiedforusewithNitrous oxide at200 bar +10° to +60°C degree Celsius. The rated flow capacityof the automaticcontrolpanel (withone of the second stage regulator in operation) should be 2 nos. of 500 LPM at 4.2Bar line distributionpressureto meetflowrate capacity and technical specifications. supply line pressure. All regulators, piping and control switching equipment shall be cleaned for nitrous oxide service. Control panel shall provide a Flow Capacity of over 500 litres/min. It should have Digitalcolorful display. It should have Integrated & protected test point. Central regulators panel with cylinder headers each side. It should have headers which shall be complete with gas specific cylinder tailpipes. Pre-wired for alarm connection to BMS outputs. All components degreased for oxygen use .Average gas consumption indication (for not liquefied gases). Remaining gas volume indication (for not liquefied gases). It should have general maintenance indicator. It should have Pressure transmitters monitor both banks of cylinders. The system should have a universal input and work in a wide power range: AC 90 to 264 Volts 50/60 Hz. The manifold control system shall be powered by an extra low voltage on board supply. A separate power supply board should be foreseen. The controller shall include alarm connections with a wire monitoring technology and sets of BMS connections for both normally open and normally closed operation.As per technical specification. 51 SITC of CO2 Manifold (2x 6) as per Fully complies to HTM02-01/NFPA99 /EN/DIN/ISO7396-1Standard and technical specifications. . It should be US FDA/ European CE with four digit notifiedbody number American ETL/Americal UL Listed.. All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders. As per technical Specification 52 SITC of Emergency CO2 Supply System (2 x 2 ) as per fully complies HTM02-01/NFPA99 /EN/DIN/ISO7396-1Standard and technical specifications. It should be US FDA/ European CE with four digit notifiedbody number American ETL/Americal UL Listed.. All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders. As per technical Specification 53 SITC ofCentral Medical Vacuum Plant of 10,000 LPMas working and 10,000LPM as standby (Package unit) of 50 Hz. as perHTM02-01/NFPA99 /EN/DIN/ISO7396-1Standard with four digit notified number specified . It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listed . The medical vacuum plant shall be manufactured under ISO-9001-2015. ISO 13485:2016, EN ISO 13485:2016quality management system, comprising of 4 X 22 KW rotary vane vacuum pumps (each Vacuum Pump two working and two as stand by)4x2000litres capacity vertical vacuum receiver tanks as per BS 5169:1992. (Receiver tanks shall be supplied with relevant test certificate)For DIN Each and every component of the system must be in accordance with DIN EN ISO 7396- Fully compliant to NFPA-99 must be UL listed Category 1 as per medical gas categorisation. As per technical specification. 54 SITC of Pentaplex Medical Air PlantIt shouldbeOil-LessScrewCompressors toproducesthe plant output of plant having having a Total Plant capacity of Minimum 10,000LPM. Main componentsof MedicalAir Plantmust havescrew compressors (Pentaplex), It should consist of pentaplex imported medical air compressor.It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listed. Itshall, be CE marked as class IIb medical device 93/42/EEC with four digit notified number specified . The Air Compressor 2 X 2000litres capacity vertical Air receiver tanks as per BS 5169:1992. (Receiver tanks shall be supplied with relevant test certificate).The medical compressed air must be manufactured under ISO-9001-2015. ISO 13485:2016, EN ISO 13485:2016 qualitymanagement systemdulycertifiedwithcopyofcertification, mustbe Fully compliant with DIN ISO 7396-1:2007 Fully compliant to NFPA-99 must be UL listed Category 1 as per medical gas categorization As per technical specification. 55 SITC of Vacuum Unit as perHTM02-01/NFPA99 /EN/DIN/ISO Standard and technical specifications.It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listedTIt should be continuous vacuum regulator, compact, strong and ergonomic device. It should have manual adjustment of the vacuum gauge from -45degree to +45degree for a better visibility. Vacuum gauge should be protected by a plastic housing. It should have on/off switch-button providing a quick restoration of thepre-adjusted vacuum level. It should have central regulation knob with a free rotation at the end of the course (impossible blocking). It should have quick adjustment :2.5turns are enoughto reach the maximum vacuum level. It should have vacuum levels :0-1000m/bar.Thevacuum regulator should be 3-in-1 system. It should have a device with a metal outlet tubing nipple integrated in the body of the regulator for a better safety, emergency suctions can even be processed. It should be supplied with a 100ml safety jar equipped with a mechanical anti-over flow safety valve and single use antibacterial plastic filter upfront. The safety jar should be made of polycarbonate, autoclavable up to 134degree C and unbreakable. The safety jar should be fixed by an easy-click rotation. The safety jar should be able to rotate to avoid any pinch of the tubing. It should have a unit serial number laser engraved on the body of each vacuum regulator ensuring its identifications and traceability. And One Polysulphone collection jar of 1000ml with lid : It should be unbreakable and autoclavable upto 134º C must be fitted with an extremely simple anti overflow safety device, thereby ensuring easy maintenance. Should be totally transparent, they ensure perfect sucked liquid visibility. 56 SITC of Theatre Suction Unit as per Fully complies to HTM02-01/NFPA99 /EN/DIN/ISO Standard and technical specifications.It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listed.shall, be CE marked as class IIb medical device 93/42/EE CE with four digit notified number specifiedIt should be continuous vacuum regulator, compact, strong and ergonomic device. It should have manual adjustment of the vacuum gauge from -45degree to +45degree for a better visibility. Vacuum gauge should be protected by a plastic housing. It should have on/off switch-button providing a quick restoration of thepre-adjusted vacuum level. It should have central regulation knob with a free rotation at the end of the course (impossible blocking). It should have quick adjustment :2.5turns are enoughto reach the maximum vacuum level. It should have vacuum levels :0-1000m/bar.Thevacuum regulator should be 3-in-1 system. It should have a device with a metal outlet tubing nipple integrated in the body of the regulator for a better safety, emergency suctions can even be processed. It should be supplied with a 100ml safety jar equipped with a mechanical anti-over flow safety valve and single use antibacterial plastic filter upfront. The safety jar should be made of polycarbonate, autoclavable up to 134degree C and unbreakable. The safety jar should be fixed by an easy-click rotation. The safety jar should be able to rotate to avoid any pinch of the tubing. It should have a unit serial number laser engraved on the body of each vacuum regulator ensuring its identifications and traceability. And Two Polysulphone collection jar of 2000ml with lid : It should be unbreakable and autoclavable upto 134º C must be fitted with an extremely simple anti overflow safety device, thereby ensuring easy maintenance. Should be totally transparent, they ensure perfect sucked liquid visibility. 57 SITC of Duplex AGSS System 2500 lpmworking and 2500 lpm as stand by of 50Hz as per Fully complies to HTM02-01/NFPA99 /EN/DIN/ISO7396-1Standard and technical specifications. . It should be US FDA/ European CE with four digit notifiedbody number American ETL/Americal UL Listed. The plant shall be a duplex configuration such that the vacuum supply is maintained in single fault condition. The stated volumetric flow rate shall be delivered with one blower on standby. The entire AGS Plant shall be skid mounted, fully assembled and factory tested as a complete system. Regenerative Blowers : Two equally sized regenerative blowers shall be provided. Blowers shall be oil-less, air cooled side channel regenerative type, suitable for both continuous operation and frequent start/stop. The motor shall be directly coupled to a fully enclosed impeller with contact free operation. As per technical specification 58 SITC of AGSS remote indicator as per Fully complies to HTM02-01/NFPA99 /EN/DIN/ISO7396-1Standard and technical specifications . It should be US FDA/ European CE with four digit notifiedbody number American ETL/Americal UL Listed. It should be 24 volt on/off room controller indicating ‘red’ plant failed, ‘amber’ duty pump failed and ‘green’ mains airflow on. As per technical specification 59 SITC of AGSS reservoir as per Fully compliesHTM 02-01/ NFPA 99 C/EN/DIN/ ISO 7396-1 Standard. The AGSS Receiver is the practical solution for waste anaesthetic gas discharges and is designed as an integral part of any waste anaesthetic gas system. The receiver comes complete with a transfer system, outlet hose assembly, and user instructions, making it ready for immediate use. Transfer system- connects to the patient circuit or anaesthetic machine and comprises a 1.5 metre length of 30 mm clear disposable tube with a male 30 mm taper for connection to the side of the receiver, and a 30 mm female tapered breathing circuit connector.It should have air break which prevents suction from the disposal system being transferred to the patient -flow indicator. Under normal operating conditions the indicator should be visible. -gauze filter built into the top of the vessel to prevent gown fluff and other solid material from reaching and blocking the fixed extraction system. Receiver vessel for active anaesthetic gas scavenging systems body - anodised aluminium, powder coated Collar and Cap - anodised aluminium Indicator Window - clear acrylic Indicator Float - low density polyethylene. It should have flow indicator 60 SITC of AGSS Hose Asembly as per It should complies with HTM 02-01/ NFPA 99 C/EN/DIN/ ISO 7396-1 Standard. It conducts the waste gases to the fixed system outlet point and comprises a 4 metre length of reinforced clear tube (colour coded yellow and blue as per the standard). This is fixed to the top of the vessel allowing the tube unimpaired 360o motion to reduce strain on the unit, and tube occlusion. As per technical specifiaction 61 SITC Medical gas hose assemblies as perFully compliesHTM 02-01/ NFPA 99 C/EN/DIN/ ISO 7396-1 Standard. and technical specifications. Medical gas hose assemblies shall comply with BS EN ISO 5359, BSEN 5682. BS EN 7396-2, BS EN 9170-1 NIST fittings compliant to BSEN ISO 18082PVC hoses and hoses containing phthalates are not acceptable. Hoses shall be colour coded throughout their length as specified in BS EN 5359 as follows: Medical oxygen - white Nitrous oxide – blue Medical and surgical air - black Vacuum - yellow, antistatic rubber tubeAll hoses shall incorporate an anti-static inner core. Hose shall be permanently secured to all fittings with stainless steel crimped ferrules, and shall incorporate a window to enable verification that the hose is fully secured onto the hose barb.Low pressure hose assemblies shall be in accordance with DINISO 5359 for coupling into outlet Colour coding must be in accordance with ISO 32. Angle type plug and NIST fittings must be in accordance with DIN 13260-2 and DIN EN 15908 respectively Hose assembly shall consist of a UL-listed high-pressure color-coded conductive hose with a DISS nut and gland on the upper end. Provide a DISS Hand-I-Twist check unit on the lower end for all services except AGSS/WAGD. Provide a Diamond quick-connect on the lower end for the Waste Anaesthesia Gas Disposal service 62 SITC of Bed Head Wall Panel 1200 mm as per It should complies withHTM02-01/NFPA99 /EN/DIN/ISO7396-1Standard and technical specifications.It should be US FDA/ European CE with four digit notifiedbody number American ETL/Americal UL Listed Bidder must submit copy ofUL Listed or ETL Listed Certificate or US FDA Certificate or notified body CE certificate as per medical devices regulations with four digit number on each item. It should be made up of Aluminum extrusion profiles with aluminum alloy 6063 temper T6. It should be manufactured from Virgin Aluminum’ no scrap added in aluminum). All sections are anodized aluminum except top plate. The top plate will be aluminum powder coating (high quality). It should have 4 Channel Channel-1“ Separate row /separate channel”for gas outlet points with pre piping side entry (Pre Piped with 4nos. gas outlet points factory tested)Channel-2“ Separate row /separate channel” for electrical sockets with pre wiring (Pre wired with 6nos. electrical sockets factory tested)Channel-3“ Separate row /separate channel” for data sockets and nurse call switch ( low voltage)Channel-4“ Separate row /separate channel” for built in LED Light Built in high strength anodized aluminum rail of full length without any joint As per technical specification 63 SITC of Bed Head Wall Panel 1500 mm as per fully complies HTM02-01/NFPA99 /EN/DIN/ISO7396-1Standard and technical specifications. It should be US FDA/ European CE with four digit notifiedbody number American ETL/Americal UL Listed. . Bidder must submit copy ofUL Listed or ETL Listed Certificate or US FDA Certificate or notified body CE certificate as per medical devices regulations with four digit number on each item.It should be made up of Aluminum extrusion profiles with aluminum alloy 6063 temper T6. It should be manufactured from Virgin Aluminum’ no scrap added in aluminum). All sections are anodized aluminum except top plate. The top plate will be aluminum powder coating (high quality). It should have 4 Channel Channel-1“ Separate row /separate channel”for gas outlet points with pre piping side entry (Pre Piped with 4nos. gas outlet points factory tested)Channel-2“ Separate row /separate channel” for electrical sockets with pre wiring (*Pre wired with 6nos. electrical sockets factory tested)Channel-3“ Separate row /separate channel” for data sockets and nurse call switch ( low voltage)Channel-4“ Separate row /separate channel” for built in LED Light Built in high strength anodized aluminum rail of full length without any joint As per technical specification 64 Loakable Line Valves as perHTM02-01/NFPA99 /EN/DIN/ISO7396-1Standard and technical specifications. It should be US FDA/ European CE with four digit notifiedbody number American ETL/Americal UL Listed.. Degreased Medical Lockable Ball Valve with Pipe line assembly. Ball valves should be Lockable and ball-type. Pre Piped Degreased Ball Valve with pipe extension. It should be full-port design. It should be blow-out proofstem. It should be lockable valve. The Valve shall be ball-type design with a bronze body and chrome plated brass ball for sizes 1/2” to 4”. Seats shall be Teflon (TFE) and seals Viton. A blow-out proof stem shall be used and the valve shall have a maximum pressure rating of 600 psi [4,137 kPa].Valves shall be operated by a lever-type handle requiring only a quarter turn from a fully open position to a fully closed position. Each valve assembly shall be washed and degreased for medical gas service. The valve shall be supplied in a sealed plastic bag to prevent contamination prior to installation. Complete Valve should be individually packed.12mm As per technical specification. 65 15 mm as per (above Item. No.50) Specification&technical specification. 66 22 mmas per (above Item. No.50)Specification&technical specification. 67 28 mm as per (above Item. No.50) Specification&technical specification. 68 42 mm as per (above Item. No.50) Specification&technical specification. 69 54 mm as per (above Item. No.50 ) Specification&technical specification. 70 108 mm as per (above Item. No.50 ) Specification&technical specification 71 Electrical Control Panel for Vacuum Pumps : The electrical control panel shall be cubical type made of CRCA sheet of 16 SWG with epoxy powder coating. The panel shall offer the following facilities. Main incoming MCCB of required capacity with bus bar system and light indications for incoming, for outgoing power supply with 4” size digital voltmeter and ammeter with selector switches.And Electrical Wiring for vacuum pumps and its accessories inside plant room: Hospital will supply 3 phase cable with distribution board and at one point inside the plant room. Electric cable with fixtures and fittings for manifold room will be done by MGPS Vender. 72 Electrical Control Panel for Air Compressors : The electrical control panel shall be cubical type made of CRCA sheet of 16 SWG with epoxy powder coating. The panel shall offer the following facilities. Main incoming MCCB of required capacity with bus bar system and light indications for incoming, for outgoing power supply with 4” size digital voltmeter and ammeter with selector switches.And Electrical Wiring for air compressors and its accessories inside plant room: Hospital will supply 3 phase cable with distribution board and at one point inside the plant room. Electric cable with fixtures and fittings for manifold room will be done by the MGPS Vender. 73 Electrical Control Panel for AGSS Plant : The electrical control panel shall be cubical type made of CRCA sheet of 16 SWG with epoxy powder coating. The panel shall offer the following facilities. Main incoming MCCB of required capacity with bus bar system and light indications for incoming, for outgoing power supply with 4” size digital voltmeter and ammeter with selector switches.And Electrical Wiring from each OT to AGSS Pump 74 SITC ofSupply, Installation, Testing & Commissiong of Liquid Medical Oxygen System, 20KLLOM OxygenCryogenicTank, Vaporiser and PRV System withone time LMO license from PESO, fees for first 5 years.As per technical specification. 75 3.00 Pneumatic Tube System Hard- and Software componentsincl. power supply, PC, monitor, keypad and all necessary parts- Remote graphic visualization in real time- automatic transfer rate adjustment- dynamic route calculation,- Rerouting Time Profiles- Integration of system monitoring into the network- Dynamic carrier tracking in the intranet for RP-users via a web browser- graphical representation of transport routes of individuel transports- Real-time transport information, Active transports, Incoming transports- carrier administration- graphical representation of transport routes of individual transports(uTID)- RFID-Transponder for reading and writing physically information on the Transponderchip (datasheet must be attached to the offer)- Automatic redirection to the service station to reach a defined number of transports.- Automatic redirection to the cleining station to reach a defined number of transports.(Software description must be attached to the offer) 76 Compact-CTU with linear axis to connect up to 4 individual LinesSimple Compact design Due to less space a maximum size of H / B / W in mm = 980 x 1010 x 570 is not allowed to exceed- Connecting several distributor via direct Line with- multi-carrier mode (up to 6 carriers at the same time)- Line connecting input above - output below; for rapid transit handover- Connection of laboratories by direct line with multi-carrier operation- Output memory for bidirectional lines- Dynamic routing functions- Traffic and transit control- Prioritizing emergency transports- RFID-Transponder reader at each CTU-entryTo minimize spare parts the identical electronics provide all PTS-devicesFasteners and accessories; deliver and assemble:(Dimensional drawing must be attached to the offer) 77 Blower 400V~ FU-suitable Protection class: IP54 with:- electric blower control- integrated reversing machine - air diverter is not allowedincl. soundproof mounting and necessary accessories; deliver and assemble: 78 PTS-Station sending and receiving NW 160, Frontloadingstation,Due to less space a maximum size of H / B / W in mm = 580 x 470 x 510 is not allowed to exceedMetal housing in RAL7035 with:- receiving basket- carrier shelf- electromagnetic lockable transparent front door- closed front door of the station in idle mode- Display and front door at the same height- simultaneously receiving and discharging of carriers if front door is open- To avoid crowded baskets, Station lower edge above ground at least 160 cm- sending storage for one carrier- pneumatic brake- LCD graphic display with 128x64 pixel- electronic address list- menu supported service functionsTo minimize spare parts the identical electronics provide all PTS-devicesincl. driving tube compounds, Fasteners and accessories; deliver and assemble(Dimensional drawing must be attached to the offer) 79 PTS-Station sending and receiving NW 160, Compactstation,Due to less space a maximum size of H / B / W in mm = 350 x 540 x 280 is not allowed to exceedMetal housing in RAL7035 with:- receiving basket- carrier shelf- sending storage for one carrier- pneumatic brake- LCD graphic display with 128x64 pixel- electronic address list- menu supported service functionsTo minimize spare parts the identical electronics provide all PTS-devicesincl. driving tube compounds, Fasteners and accessories; deliver and assemble(Dimensional drawing must be attached to the offer) 80 PTS-Diverter NW160 Typ 3-wayDue to less space a maximum size of H / B / W in mm = 470 x 800 x 370 is not allowed to exceedMetal housing in RAL7035driving tube compounds,Incl. optical transmission sensorBelt drive including slip clutchTo minimize spare parts the identical electronics provide all PTS-devicesincl. driving tube compounds, Fasteners and accessories; deliver and assemble(Dimensional drawing must be attached to the offer) 81 PTS-Station receiving NW 160, Lab or receiving station incl. reception chute,Metal housing in RAL7035 with:- pneumatic brake- Connection for conveyor belt (optional)- automatic detection Strap perfectTo minimize spare parts the identical electronics provide all PTS-devicesincl. driving tube compounds, Fasteners and accessories; deliver and assemble 82 PTS-Carrier NW 160- 2x rotating slide lid- Slide lid 360 ° rotatable, suitable for right and left hander- loadable of cd/dvd- RFID-Transponder for reading and writing physically information- suitable for automatic unloading station 83 PTS-Driving Tube, PVC light grey Ral7000 building class BK 1, NW 160x3,2,inclusive sleeve, compounds, Fasteners and accessories; deliver and assemble: 84 PTS-Driving Tube Bend, PVC light grey Ral7000 building class BK 1, NW 160x3,2, R 800, 90°,inclusive sleeve, compounds, Fasteners and accessories; deliver and assemble: 85 PTS-Driving Tube, UPVC transparent; building class BK 1, NW 160x3,2,inclusive sleeve, compounds, Fasteners and accessories; deliver and assemble: 86 PTS-Driving Tube Bend, UPVC transparent building class BK 1, NW 160x3,2, R 800, 90°,inclusive sleeve, compounds, Fasteners and accessories; deliver and assemble: 87 PTS-twisted pair data cable with integrated power supply for the devicesincl. mounting and necessary accessories; deliver and assemble: 88 Modular Operation TheaterSITC of Wall Panel- • It should be European CE Declaration of Conformity only.•The wall system should be based on a technological modular unit designed to clad and to divide interior space in controlled bacteria environments in a flexible and functional manner.• The design ensures that the unique self-loading and free-standing substructure can be clad with all types of engineered finishing panels without use of screws and any other fixed mechanical joints (Screw less Technology). • The outer surface of a wall surface should be created with high –tech materials such as structural Solid Mineral Composite Sheet (SMS). • System should offer total ease of cleaning and sanitization of the partitions.It should have no corners and adjacent surfaces should be moulded flush by means of connecting elements.• System should afford the maximum versatility at the planning stage and flexibility during erection, ensuring openness to future alternations and trouble–free maintenance.During the installation, first the structural parts and subsequently the finishing elements to be installed.• The system should ensure perfect integration of technical networks and allow ample operational flexibility on the construction site.The clean, dry installation method should enable optimum programming of the various work phases, allowing optimization of the installation of technical systems and any necessary alterations to be made–right up to checking and final testing of the installed systems – before the modules are sealed.• Wall panels: Cladding shall be full body structural panels in Solid Mineral Surface Sheet (SMS) min thickness of 12mm and aluminum backing• The Solid Mineral Surface (SMS) material should be dent free antibacterial & fire resistant.• The Solid Mineral Surface (SMS) should not require any paint & should have in built antibacterial properties.• The material should have antibacterial activity (%reduction>99%).• Sub Frame/Structure: Sub Structure frame made of galvanized steel pillars with broad cross section, with geometry designed to achieve exceptional rigidity.The substructure, with its FREE-STANDING technology, minimizes the interference with all electro mechanical systems to be installed.Possible to adjust and secure the profiles, ensuring the maximum rigidity and self-loading capacity of the sub frame system.• a)Wall Corners: Angular corners made with a 130°-140° angular modular element with the same finish of the wall panels. Such unit is internally completed by a recovery duct formed by a single sheet/SMS, perfectly integrated and shelled in order to allow the correct element sanitization. A removable front panel allows both access to the canal behind either the regulation of the air flow between the lower and upper opening. • b) Sealing Gaskets/Material: Should be non-toxic silicone rubber/material around all the contact perimeters between the various materials, and the hermetically sealed gaps between modules, should ensure optimum space segregation and ensure that sterile air pressure values are maintained in the protected environment, this be being a fundamental prerequisite for guaranteed sterility.As per Technical Specifications of the Tender 89 SITC of Ceiling panel - Hermentic Suspended Ceiling - • • It should be European CE Declaration of Conformity only• The hermetic suspended ceiling should be a loading structure in heavy gauge material forming the grid on which the ceiling panels made of Solid Mineral Composite Sheet (SMS) thickness of 06mm.The total thickness of panel including Aluminum backing should not be less than 18mm.• The hermetic suspended ceiling should be a loading structure in heavy duty aluminum extruded material forming the grid on which the ceiling panels made of Solid Mineral Sheet (SMS) thickness of 3mm are installed. The panel should include aluminum backing• The modular grid, which can be 600x600 mm, or variable, allows the integration of sealed lighting fixtures, air anemostats and/ or various service units.• The variable module grid should make it possible to adapt the size of the ceiling module to match the equipment to be mounted.• It should also allow the use of different module sizes within the same room.• The grid should be formed of loading profiles, suspended from the ceiling slab, to which the crossbar profiles are secured by means of rigid mechanical couplings.• The thus formed grid should be rigid and remains perfectly stable during all the subsequent site operations.• The suspended ceiling should be hermetically sealed. It should be durable and non degradable and resistant to micro organism attack .• The function of silicon sealing should be that of assuring an airtight environment in the room and eliminating cervices in which dust could accumulate.• The gaskets to be made of non-toxic silicon in compliance with regulations applicable to cleanrooms.As per Technical Specifications of the Tender 90 SITC of Laminar air flow ceiling - 1no. for each OT (inside OT work only): • The laminar air flow should be supplied at site duly sealed in factory made packing. The laminar air flow unit should be made ofaluminium. The Laminar flow system should have galvanized steel perforated diffuser grill.Front diffuser in painted galvanized steel sheet, demountable from the room side.• The plenum box (2400mm x 2400mm) will be made of high quality Aluminum 1.6mm thick & Air diffuser will be made of Woven polyester cloth that will introduce the highest air quality into the Operation Theatre. There will be 8 HEPA filters (as per plenum size) with 99.97% efficiency to ensure high quality clean air & tight control of bacteria infection system. Filter typeHepa and filter efficiency: 99.995% MPPS sec. - Filter class: H14 to EN 1822• Air will be diffused into the theatre uniformly over the total area through perforated aluminum sheet. The air distribution system serving to the Operation Theatre will be tested as per DIN 4799 standards. • Filter ceiling system designed to create sterile and clean zones in operating suites, composed of: - Airtight terminal filter modules build ofextruded anodised aluminium profiles. It should as per ISO 14644. Copy of the same should be submitted.• The laminar flow installation & lighting system will be design to provide the Operation Theatre as key to preventing patients being infected during operation lies on the design of sterilized air conditioning system and the flow pattern of draught as well as the quality of engineering. The ceiling will incorporate supports to secure it to the main structural frame of the modular operating theatreAs per Technical Specifications of the Tender 91 Hermetically Sealed Sliding Door - : The main door will be of Single Flap with frame size 1500mm wide x 2100mm height. WITH PANEL OF 300 x 300 mm• Automatic hermetically sealed sliding door with single leaf, for use in controlled bacteria environments, the door can be installed in conventional masonry walls or prefabricated self-loading systems. Telescopic linings on three sides, made in two parts, the frame profile and the sub frame profile, made of extruded aluminium elements shaped with wide radius curves.• The main door will be of Single Flap with frame size 1500mm wide x 2100mm height and view panel of 300 x 300 mm.• Frames: The constructions Frames will be in accordance with the existing pre fabricated wall thickness, with the fastenings to the wall panel, with horizontal upper drive gear boxes and in the double door width, incl fascia. Running in front of the wall. Floor in stand for the framepillar: 30mm. The frames will be provided in Aluminium extruded profiles which will with stand better structural load anodized to make dust free. The frame thickness will be 2.0mm &sheet thicknesswill be 1.5mm. The width of 50 mm only extruded profiles shall be used for construction of frames. Sandwich door leaf of thickness 35–40mm will be completely covered with a high-density solid car and in order to prevent the door from buckling by using a special glue on both sides.•AUTOMATION: Automation for sliding doors, complete with: Operating system transmission with antistatic drive belt reinforced with Kevlar beads; 230 V AC — 50 Hz power supply with short-circuit protection; High-performance low-wear DC motor; Status signalling and fault indicator LEDs. Electronic controller: Teach-in function with self-diagnostics and error recognition with evaluation of door leaf weight and sliding friction for adaptation of transmitted drive torque; ; Pause time for fully open doorIndependently adjustable opening and closing speeds. Anti-crushing function with closing movement reversal ; Battery powered emergency opening or closing; Back-up batte to open or close the door in the event of an electrical power outag. The door is equipped as standard with two large size elbow-operated pushbuttons, back-up battery unit for emergency opening during power outages (the door stops in the open position in order to identify the presence of a fault in the electrical circuit) and a display-type program selector.• The display-type program selector has 5 settings. Partial opening, Total opening, Permanent opening, Off/Locked, Single Direction of Operation.• Touch - type opening controls, radar-operating controls etc. Display Type Programmer Selector Switch with 5 Settings (2 Nos for each Door). Two Large Size Elbow Push Switch (On Both side of each Door). Touch Type Foot Switch (On Both side of each Door). Contactless Switch (On Both side of each Door). Back up Battery Unit for Emergency Opening during Power Outages, Radar Operating Controls– (On Both Side of Door). Sliding Door should compose of the following:sliding mechanism and housing of protection, Automation with drive, power supply and motor, Controls and safety devices EN 16005, Double aluminum handle, Leaf panel with aluminum profiles (linings, housing and profiles in Anodized Aluminum), Hermetically sealed in cl.3-4 according to EN12207.Finishing coat: ASEPSI ANTIBACTERIAL SMS alongwith FLUSH VIEWING WINDOW.• The total thickness shall be 60mm. The door leaves should be manufactured without impact at the front surface. They will close tightly and installed at the front and rear to prevent the door from closing sharply.Each leaf will have:A. Stainless steel handles with Matt finish on one wall at each side, which allows the door to be opened with hand, elbow B.Moderately heavy mortise lock, upward closing, pre-fittedfor profile cylinder including closing angle, collars.C. Inspection window: An inspection window will be installed in the, glass strips in Aluminium sheet. The window size will be 300x300mmD. Opening and closing of the door shall be microprocessor controlled electro-mechanical movement.E. The door material shall be of SMSColour shall match the interior and care shall be taken to make the leaf strong and lightweight.F. Motor used shallbePMDC motors with essential isolation from mains. As per Technical Specifications of the Tender 92 Hermetically Sealed Sliding Door with Lead Lining- : The main door will be of Single Flap with frame size 1500mm wide x 2100mm height. WITH PANEL OF 300 x 300 mm• Automatic hermetically sealed sliding door with single leaf, for use in controlled bacteria environments, the door can be installed in conventional masonry walls or prefabricated self-loading systems. Telescopic linings on three sides, made in two parts, the frame profile and the sub frame profile, made of extruded aluminium elements shaped with wide radius curves.• The main door will be of Single Flap with frame size 1500mm wide x 2100mm height and view panel of 300 x 300 mm.• Frames: The constructions Frames will be in accordance with the existing pre fabricated wall thickness, with the fastenings to the wall panel, with horizontal upper drive gear boxes and in the double door width, incl fascia. Running in front of the wall. Floor in stand for the framepillar: 30mm. The frames will be provided in Aluminium extruded profiles which will with stand better structural load anodized to make dust free. The frame thickness will be 2.0mm &sheet thicknesswill be 1.5mm. The width of 50 mm only extruded profiles shall be used for construction of frames. Sandwich door leaf of thickness 35–40mm will be completely covered with a high-density solid car and in order to prevent the door from buckling by using a special glue on both sides.•AUTOMATION: Automation for sliding doors, complete with: Operating system transmission with antistatic drive belt reinforced with Kevlar beads; 230 V AC — 50 Hz power supply with short-circuit protection; High-performance low-wear DC motor; Status signalling and fault indicator LEDs. Electronic controller: Teach-in function with self-diagnostics and error recognition with evaluation of door leaf weight and sliding friction for adaptation of transmitted drive torque; ; Pause time for fully open doorIndependently adjustable opening and closing speeds. Anti-crushing function with closing movement reversal ; Battery powered emergency opening or closing; Back-up batte to open or close the door in the event of an electrical power outag. The door is equipped as standard with two large size elbow-operated pushbuttons, back-up battery unit for emergency opening during power outages (the door stops in the open position in order to identify the presence of a fault in the electrical circuit) and a display-type program selector.• The display-type program selector has 5 settings. Partial opening, Total opening, Permanent opening, Off/Locked, Single Direction of Operation.• Touch - type opening controls, radar-operating controls etc. Display Type Programmer Selector Switch with 5 Settings (2 Nos for each Door). Two Large Size Elbow Push Switch (On Both side of each Door). Touch Type Foot Switch (On Both side of each Door). Contactless Switch (On Both side of each Door). Back up Battery Unit for Emergency Opening during Power Outages, Radar Operating Controls– (On Both Side of Door). Sliding Door should compose of the following:sliding mechanism and housing of protection, Automation with drive, power supply and motor, Controls and safety devices EN 16005, Double aluminum handle, Leaf panel with aluminum profiles (linings, housing and profiles in Anodized Aluminum), Hermetically sealed in cl.3-4 according to EN12207.Finishing coat: ASEPSI ANTIBACTERIAL SMS alongwith FLUSH VIEWING WINDOW.• The total thickness shall be 60mm. The door leaves should be manufactured without impact at the front surface. They will close tightly and installed at the front and rear to prevent the door from closing sharply.Each leaf will have:A. Stainless steel handles with Matt finish on one wall at each side, which allows the door to be opened with hand, elbow B.Moderately heavy mortise lock, upward closing, pre-fittedfor profile cylinder including closing angle, collars.C. Inspection window: An inspection window will be installed in the, glass strips in Aluminium sheet. The window size will be 300x300mmD. Opening and closing of the door shall be microprocessor controlled electro-mechanical movement.E. The door material shall be of SMSColour shall match the interior and care shall be taken to make the leaf strong and lightweight.F. Motor used shallbePMDC motors with essential isolation from mains. As per Technical Specifications of the Tender 93 SITC of Stainless Steel Storage Unit: Storage Unit should be made out of 0.8 - 1 mm thick AISI-304 Stainless steel. The storage unit should be divided 2 or more parts and each part should have individual glass doors with high quality locking system. These doors should be installed on the storage units with the help of imported fittings allowing an opening allowance of 90-100 degree. Each part should be provided with Stainless steel-304 racks which should be completely detachable type. The storage unit should be fitted with glass doorand mounted flush with the theatre wall. The dimensions of each storage unit should not be less than height 2000mm x 1200mm width x depth 350-400 mm. The storage units should be designed in a way that they are flush with the OT wall panels and the units should be air tight, not allowing any leakage between units and the wall panels.- As per Technical Specifications of the Tender 94 SITC of 2mm Flooring:• The floor finish in the operating room will belaid with 2 mm antistatic seamless conductive PVC Roll Static dissipative PVC roll type, laid on a semi conductive adhesive base.• The floor should be scratch resistant, fire resistant, chemical resistant, non-corrosive, slip resistant, smooth, anti fungi, antimicrobial impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock.• The floor finish will terminate at the room perimeter passing over a concealed cove former and continuing up the wall for 100mm.• Flooring will fulfil EN 649 of US requirements. It will have chemical resistance as per EN 423. It will have electrical resistance conforming to EN 1081/IEC 61340.• All joints will be welded and the plastic wall finish will overlap the floor coving by 25mm, to provide a continuous sealed surface. A floor screed will be provided, flat to within a tolerance of +/- 3mm over any 3-metre area. Onto this sub floor, a self-leveling compound will be laid prior to laying of the floor finish. The self-leveling compound will be of the type that does not promote bacteriological growth. Copper grounding strips (0.05mm thick, 50mm width) will be laid flat on the floor in the conductive adhesive and connect to copper wire of grounding.• The joints in the flooring should be sealed by using a PVC welding bar of matching colour and hot air gun for fusion of welding bar with flooring to provide a continuous sealed surface, confirming the European/US standards. The sheets should be highly durable with resistance to shock, scratch proof and indentation. Corners should be uniformly curved. The conductive material should be uniformly impregnated as grains. The floor should be inert to body fluids, chemicals, detergents and disinfectants and it should not be affected by temperature variation within the OT. Colour should be uniform, pleasant and matching with ambience. - As per Technical Specifications of the Tender 95 SITC of Dimmeble Peripheral light cum clean room luminaries:• It should be fitted outside the air ceiling system area and flush with the ceiling in the operation theatre suitable to required illumination (450-500 Lux) of OT. Peripheral lights should be LED based (Size-2ft x 2ft approx. size ) and clean room luminaries fitted in the frame should be 8 in numbers for each OT. • Double peripheral OT lights each set having two lights IP 65 Grade should be provided with stepped finish of A class for use in clean room application. The peripheral light diffusers will be constructed from aluminium frames. Light will be generated from high frequency Drivercomplete with colour corrected fluores incorporate supports to secure it to the main structural frame of the modular operating theatre. • The fluorescent lamps / Non-hygroscopic high glow low power LED based peripheral lights having high quality low wattage LED lighting system with highly spectacular anodized Aluminum reflectors and optical antiglare system for adjustable light distribution. • Luminaire cover made of highly resistant, disinfectant proof laminated safety glass with fine grained surface, glass pane with white powder coated steel frame.• Luminaire body made of sheet steel, white, powder coated supplied ready for connection. Drivers of reputed companies to be used and diffuser should be constructed with opaque acrylic diffuser material in aluminum frames. It should have flicker less design with color. Lighting units should be properly sealed with the ceiling by means of fillers and beadings so that all lighting units are airtight with ceiling panels. The light fitting should be uniformly and aesthetically distributed on the ceiling to provide uniform illumination in the OR.• Control equipment for the peripheral lighting should be provided in the theatre control panel to allow independent control of the lighting levels by the surgical team. The operation procedures cannever be affected byshadows, shimmering lights and dazzling eyes. This has been achieved by the lighting system with sufficient illumination level at the wound site and to provide flicker less design lighting control system. Controls for the peripheral lighting will be provided in the theatre control panel to allow independent control of the lighting levels by the surgical team.As per Technical Specifications of the Tender 96 SITC of Touch Surgeon Control Panel:• It should be European CE . Itshould be designed to cope with changing technology and equipment in operating environments. • Control panel should be user friendly and ease of operating and maintaining purpose. Imported Touch Screen Surgeon Control Panel for Operation Theatres with IPS: It should be flush to wall touch screen application for operating theatres, protected by a glass surface that enhances its features and performance in a critical environment of an operating room, coplanar to the finish panel (with the exception of the panels with metallic finish. • Touch Screen Surgeon Control panel is recessed box kit for screen 31.5” to 32. 1 x Hardware and software kit for touch screen, with PC intel NUC, PLC and software. For lighting management with DALI protocol. 1 x Capacitive touch screen 32, FULL HD resolution, 1 x Humidity and temperature sensor, 1 x Differential atmospheric pressure sensor for ambient, 1 x Differential atmospheric pressure sensor for filter. It should have IPS alarm and memory for fault status report. • The connection between the surgeon control panel and the distribution board should be by a multiplexed system, providing a PWM signal on a two-core cable. • The panel will contain 6 services as follows:a). Time dayclockb). Time Elapsed Clockc). Temperature &Humidity Indicator d). General/peripheral Lighting controle). Medical GasAlarmPanel – upto 6 gases f) Hepa Filter status• All high voltage equipment should be installed in a separate enclosure. The remote cabinet will house the operating lamp transformers, mains failurere lays, electrical protection equipment for all circuits within the operating theatre.• All internal wiring will terminate in connectors with screw and clamp spring connections of the Clip and labelled with indelible proprietary labels.• Individual fuses or miniature circuit breakers will protect all internal circuits.• All internal wires will be marked with plasticferrule type cable markers, forease of identification. - As per Technical Specifications of the Tender 97 SITC of Medical Isolation Panel:• Isolation Panel System of minimum 20 KVA capacity should be provided for every operation theatre which ensures the safety of staff and patient. System should have isolators provided through leakage relays etc. (If required) according to IEC recommendation. • This unit should be European CEcertified. Fully complies with EN standard IEC 60364-7-710 , CEI 64-8/7 CAP.710, CEI EN 61558-2-15 regulation . Should be compliant to CEI 64-8 / IEC 60364-7-710/BS7671 Standard .These systems are to be commissioned by specialists. • Should be medical grade Isolation panel. Should have fault detection feature. • They guarantee total protection from macro and micro shock through electrical segregation between utiliser and electric net.• Dimensions of The medical isolation panels are 1300mm height x 800mm width x 400mm depth so that same can be flushed in the wall. The double frontal window is mechanically interlocked. • The panels should be supplied for 20 kVA (10KVA + 10kVA units for each OT) to meet all the possible applications required in the medical spaces• The isolating transformer, in accordance with the regulation 61558-2-15, ensures complete electrical segregations between the utiliser and the electric net, avoiding dangerous leakage currents in case of accidental contact. Moreover the isolating transformers are provided with a probe Pt100, enable to detect the values of the transformer working temperature, guaranteeing the real-time monitoring of the operative conditions. The monitoring devices are equipments for DIN35 rail in accordance with the regulation 61557-8, which beyond the measure of the isolation resistance, even allow the control of the excess temperature (through probe Pt100) of the transformer, adopting in this way the recommendations included in the regulation CEI 64-8/7 2007.• The panels for medical use are considered as “Class II electromedical devices with metal case” in accordance to the article 14.2 of the regulation CEI EN 60601-1 (CEI 62-5). • Should be compact and mountable on wall or flush on brick wall. • The IPS should be able to integrate with HIS/BMS and Surgeon Control Panel as standard - As per Technical Specifications of the Tender 98 SITC of LED X-Ray View Panel: The theatre will be equipped with a 2-plate LED X-Ray viewing screen. It will be designed to provide flicker free luminance for the film viewing purpose. It is installed flushed with the theatre wall for hygienic and ease of cleaning purpose. The LED X-Ray viewing screen is designed for the purpose of front access. The LEDX-Ray viewing screen will be illuminated by LED’s and the dimming will have controlled by the usage of LED Driver. The diffuser is able to diffuse the light evenly and to provide enough luminance for film viewing. It is made of high quality opaque acrylic sheet. The film is held firmly by using spring-loaded clips for ease of mounting and demounting. Size should not be less than 940 x 640 x 50 mm (WxHXD) - As per Technical Specifications of the Tender 99 SITC of Writing Board: One Operating List Board should be provided in each Operating Theatre and should be made of Ceramic Magnetic white board. Operating List Board should be flush mounted. - As per Technical Specifications of the Tender 100 SITC of Inside OT electrical wiring and PVC conduting:Laying of PVC conduits, Modular Switch Boxes, Modular Switches-sockets, Power and Light wiring including earthing wire for all the lighting controls, Connection to media bridge/pendants and other equipment fixtures and fittings inside the theatre Wiring with low leakage current wires of FRLS wires should be as per requirements. wiring for 250 volts single phase and earth4 sq.mm and 2.5 sq.mm PVC insulated copper conductor 1100 volts stranded flexible wires should be concealed with conduit for switch & sockets. One industrial switch and socket along with suitable size of wire must be fitted inside the operation theater. It should also have 8nos. 6/16amp electrical switch sockets antibacterial shall be equidistant flushed in any 2-3 walls inside the operation theater - As per Technical Specifications of the Tender 101 SITC of Stainless SteelGrill for Return and Supply inside each OT. - As per Technical Specifications of the Tender 102 SITC of Three Bay Stainless Steel Scrub Sink: The scrub station will be equipped with 3 Bayscrub stations.The scrub station will be made of high-grade stainless steel 304 with stain polish finish and wired to the current IEE regulations & BS 7971. The scrub stations control system will be based on advanced microprocessor.The scrub station will be sensor-activated 24VAC.The scrub station will be provided with user selectable time out control. The supply will not be interrupted in case of power failure or maintenance. The station will be equipped with thermostatic mixing valve to control the temperature of hot / cold water supply. The washing faucet will be made of Chrome plated brass hand.Geyser of 3 Kw rating should be incorporated inside the Scrub sink for Hot water.- As per Technical Specifications of the Tender. 103 ) SITC of Double Dome OT Light (Camera Prepared) with axis of 3rd Monitor Arm ceiling mounted with ceiling flange : Europeon Claass-1 or UL Listed or ETL Listed or USFDA Certified - As per Technical Specifications of the Tender 104 SITC of Centrally Mounted Camera: - As per Technical Specifications of the Tender 105 SITC of 32 Medical Monitor with Monitor Arm: - As per Technical Specifications of the Tender 106 SITC of Recording System with 54Monitor: Recording system to be offered separately (Only for non integrated OT’s) Recording system to be offered separately. Recording system should be full HD medical grade monitor LCD 54 touch screen and having the one TB storage space. Data cable for communication from both pendants and monitors should be laid down up-to outside of OT in a patch port for future expansion for all OT’s where there is no integration. Patch Panel for power & signal to be laid down for 54” LCD Monitor at wall of MOT . Recorder should be capable of recording video from other sources like - microscopes, endoscopes. Etc., suitable provision should be provided as standard. Should be flushed mounted on the OT wall with suitable frame. - As per Technical Specifications of the Tender 107 SITC of Imported Digital Display PACS/HIMS Medical Grade Monitor 32” Monitor:a) Medical grade monitor size should be minimum 32 inch.b) Should be integrated with hospital PACS. Vendor has to do the necessary coordination with PACS/HMIS contractor or hospital authorities for connecting the monitor to hospital PACS/HMIS.c) If PACS/HMIS is not available in the hospital, vendor should terminate all monitorsconnection to switch (should be located at MOT corridor) from where hospital willconnect further.d) Monitor should be flush mounted with suitable frame in MOT wall. Frame should beopenable/serviceable for service.e) HD Flat Panel Monitor should be done according to IP 54 regulations. - As per Technical Specifications of the Tender 108 SITC of Double Arm Motorised Surgeon Pendant - As per Technical Specifications of the Tender 109 SITC of DoubleArm Motorised Anesthetist Pendant - As per Technical Specifications of the Tender 110 High End OT Table for Ortho OT- As per Technical Specifications of the Tender 111 High End Neuro OT Table with Neuro Frame- As per Technical Specifications of the Tender 112 High End Surgery OT Table- As per Technical Specifications of the Tender 113 High End Gyanec OT Table- As per Technical Specifications of the Tender 114 Ophthalmic OT Table (Remote Operated)- As per Technical Specifications of the Tender 115 Control cabling from AHU to MOT control panel and associated sensors 116 Online UPS for each OT and 1 Standby UPS 117 Electrical Distribution Board with 12 MCB 118 Electrical Distribution Board with 16 MCB 119 Medical Gas Pipe Line Interconnection 120 TVX and Dryer Filter 121 Micro-processor based humidity sensor& Display Panel 122 Micro-processor based Room temperature sensor & Display Panel 123 HEPA Filter Status Sensor & Display Panel 124 LaundrySITC ofBarrier Washer Extractor- For washing cleaning and extraction: Capacity -50 kg, Electric Heated & Steam Heated Dual mode, with 2 opposed door ,loading door on dirty side and unloading door on clean side. 125 SITC of Drying TumblerCapacity – 45 kgGas Heated, Total Min capacity to dry 90-95 kg per Hour. 126 SITC of Flatwork Ironer (Calendaringm/C):Gas Heated, Front Feed Front Return -500X3300mmFlatwork Ironer and a maximum ironing surface for the utmost ironing quality 127 SITC of Flat Bed Press-Electric Heated Suitable for linen like uniform, room furnishing, personal garments, Bed sheets & PillowCovers Head & Bed SizeDimensions of the universal plate - 1180X380X220 mm Steam heated, 128 SITC of Rectangular Vacuum Ironing Table :Size -1550 X 580 X950 129 SITC ofDry Linen Transportation Trolley-Capacity -50kgThe dry linen trolley shall be fabricated out of Aluminium metal and should be good quality for the better movement and performance along with moving wheels 130 SITC of Mobile Folding Table -Dimensions: 4feetX2 Feet The folding table shall be specially designed for carrying rolling and folding of linen in the laundry. The frame of the table shall be fabricated out of MS welded construction with one bottom shelf for storage. Complete with heavy duty ball bearing for swivelling wheels. The table top shall be of polished Stainless steel. 131 SITC ofFresh Linen Storage Rack Size - 1200mmx460mmx1800mm4 shelves; Made of Stainless Steel-AISI-304, Finished with Polishing. 132 SITC ofFresh Linen Transportation trolleyCapacity -50kgThe fresh linen trolley shall be fabricated out of Aluminium metal and should be good quality for the better movement and performance along with moving wheels 133 SITC ofLaundry Scrub Station with 2 Sinks. 1) Stainless Steel Construction. 2) S.S Sinks with taps for wash and rinse using hot and cold water.3) SS Scrubbing Board in between Sinks.4) Underneath Shelf. Size- 1600x500x900 ht.5) Geyser of 3Kw to be provided for Hot water 134 SITC of Hot Water System-Electric Geyser Capacity: 600 Litres per Hour This Hot water system would provide the hot water as per the capacity.1) Glass Lined Tank for water heater use.2) Anode with low level of maintenance.3) Low flue gas temperature for higher efficiency.4) Additional pressure and temperature valve for safety5) Fully automatic spark ignition & Automatic Control system 135 SITC of Electric Boiler 200kg -Steam Output-200 Kg Per Hour 136 1.00 Civil WorksSec.1.0 Earth work Providing material and labour, machinery for Excavation of foundation upto 1.5 m depth including sorting outandstacking of useful materials anddisposing off the excavated stuff with in the campus for all lead, all lift/ depth and back filling foundations, the trenches, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting. 137 Providing material and labour for Excavation of foundation from1.5 mtto3.0 mt depth including sorting outandstacking of useful materials anddisposing off the excavated stuff with in the campus for all lead, all lift/ depth and back filling foundations, the trenches, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting. 138 Providing material and labour for Disposing off the un-used excavatedearth (black cotton soil), debris, malba, dismantled materials for all lead and lift/ depth out side the campus at non objectional place as directed by Engineer in charge. 139 Providing material and labour for Fillingin plinth with sand under floors or base of foundation including watering ramming, consolidating and dressing etc complete as directed by Engineer in charge. 140 Providing material and labour for Filling in foundation, plinth and plot filling with murrum (brought from out side) in layers of 20cm. thickness including watering, ramming and consolidating etc complete as directed by Engineer in charge. 141 Providing material and labour for injecting Chemical emulsion for PRE - CONSTRUCTIONAL anti-termite treatment and creating a chemical barrier on the top surface of plinth filling, inside junction of wall and floor, on top of damp proof course (DPC) or on masonry at level of plinth filling as per IS 6313 (Part-2)-1981 using chemical like chloropyripos emulsifiable,Biflex TC, lindane (IS 8944-1978) 20EC mixed with water in 1:19 ratio (1 liter chemical : 19 liters of water). The emulsion shall mentioned below, all as per specification and directions of Engineer-in-charge.Plinth area in plan at GF shall only be measured (for akk below specified steps) and paid. A guarantee bond of 10 years shall be furnished. A1) Bottom surface and the sides of the excavation made for masonry foundations at the rate of 4 liters/sqm (wherever applicable)A2) At the rate of 7.5 liter/ sqm to the backfill at the depth of 500mm below the original ground level. The soil in the immediate contact with the vertical surfaceof RCC column/ Masonry shall be treated.B) Top surface of the plinth filling including damp proof courses at the rate of 5 liter/sqm of internal plinth area etc. complete.C) At the rate of 7.5 liter/ sqm to the internalvertical surface from original Ground level to top of the earth filled in the plinth.D) At the rate of 7.5 liter/ sqm to the externalvertical surfacebelow finished Ground level to the full depth of the filling complete.E) 1 liter / linear meter along the junction of wall and floor at all stages. 142 Sec: 2.0PCC & RCC worksProviding material and labour for laying Plain cement concrete 1:3:6 (1- Cement : 3- Coarse sand : 6- crushed stone aggregates 20 mm nominal size) in Foundation and Plinth including cost of formwork, compacting, finishing, curing etc complete for all level, all height/ depth as directed by engineer in charge. 143 Providing material and labour for laying Plain cement concrete M15 in Foundation and Plinth including cost of formwork, compacting, finishing, curing etc complete for all level, all height/ depth as directed by engineer in charge. 144 Providing material and labour for fixing TMT Bar FE 500D reinforcement for R.C.C. work including cutting, bending, binding with 18 SWG -1.22 mm GI wire and placing in position etc complete for all floors, all levels, all heights/ depth as per drawings, specifications and direction of Engineer in Charge. 145 Providing material and labour for laying in position Ready Mixed M-20 grade concrete for reinforced cement conctere work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for allelements, all floors, any heights/depths, any lead and liftas directed by Engineer Incharge. 146 Providing material and labour for laying in position Ready Mixed M-30 grade concrete for reinforced cement conctere work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for allelements, all floors, any heights/depths, any lead and liftas directed by Engineer Incharge. 147 Providing material and labour for fixing in position PVC pipe sleeves of 50mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleeve shall be removed before water proofing or grouting (at rain water down take location). 148 Providing material and labour for fixing in position PVC pipe sleeves of 75mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleve shall be remoed before water proofing or grouting (at rain water down take location). 149 Providing material and labour for fixing in position PVC pipe sleeves of 110mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleve shall be remoed before water proofing or grouting (at rain water down take location). 150 Providing material and labour for fixing in position PVC pipe sleeves of 160mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleve shall be remoed before water proofing or grouting (at rain water down take location). 151 Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC memberwithout vibration by core cutting (diamond drilling) holes from 51 to77mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency. 152 Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC memberwithout vibration by core cutting (diamond drilling) holes from 77 to102mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency. 153 Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC memberwithout vibration by core cutting (diamond drilling) holes from 102 to125mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency. 154 Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC memberwithout vibration by core cutting (diamond drilling) holes from 125 to152mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency. 155 Providing material and labour for Cutting holes of required size in brick/ block masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. 156 Rebaring :Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 8mm and depth 120mm as per manufacturer/ structural consultants specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item.Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge. 157 Rebaring :Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 10mm and depth 150mm as per manufacturer/ structural consultants specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item.Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge. 158 Rebaring :Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 12mm and depth 180mm as per manufacturer/ structural consultants specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item.Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge. 159 Rebaring :Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 16mm and depth 240mm as per manufacturer/ structural consultants specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item.Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge. 160 Chemical Anchor:Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 10mm and depth 150mm as per manufacturer/ structural consultants specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item.Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge. 161 Chemical Anchor:Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 12mm and depth 180mm as per manufacturer/ structural consultants specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item.Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge. 162 Chemical Anchor:Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 16mm and depth 240mm as per manufacturer/ structural consultants specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item.Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge. 163 Mechanical Anchor : Providing material and labour for drilling, cleaning hole and fixing mechanical anchor of size 10 X 120 of approved make and suitable for fastenings both on concrete & masonary/aerated blocks. Anchor comprises of 10 mm diameter Polyamide PA 6 grade sleeve and of 7 mm diameter double threaded 6.8 grade Hex head double threaded screw made of carbon steel galvanized to minimum 5 microns. Fixing methodology shall be followed as per manufacturer’s guidelines. for all floors, all height as directed by engineer in charge. 164 Sec.4.0 Masonry worksProviding material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg/SqCm in foundation and plinth in Cement Mortar 1:5 (1- Cement : 5 -fine sand) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge. 165 Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg/SqCm in Cement Mortar 1:5 (1- Cement : 5 -fine sand) in superstructure above plinth levelfor all Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge. 166 Providing material and labour for laying Halfbrickmasonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1-Cement : 4 -coarse sand ) in superstructure for all Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge. 167 Providing material and labour for laying Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure For all Floorin cement mortar 1:5 (1 cement : 5 fine sand)in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge. 168 SEC:5 Doors and Windows workALUMINIUM WORKS -Providing material and labour for fixing in position frames, shutter for any type of aluminium work for any type of door, window, partition, made out of any type of aluminium sections of approved make having minimum 50 micron pure polyester powder coating of approved shade, texture & colour of approved make for all floors, all levels, all heights, all shapes, all sizes including cutting, bending, crimping, fabricating in best workmanship manner etc as per the drawing, specification and as directed by Architect or Engineer-in-Charge. Contractor shall prepare shop drawing based on concept drawing and get approved from the consultants before procurement of material. All loose material shall be approved. Mockup of one/two window shall be executed as per approved shop drawing with all hardware. Work shall carried out as per the approved shop drawings, approved mock-up and approved sample. Actual weight of installed Aluminium sections (for using fabrication without considering any wastage) shall only be measured and shall be considered for the payment. Contractor shall provide guarantee for stability, water tightness etc for 12 months after defects liability period. Rate shall be inclusive of providing aluminium sections, cutting, fabrication, errection and fixing to the best workmanship manner, including1) Sheet metal screws and casted solid aluminum corner cleats fixed with external byttins with a spring for rapid and secure joint assembly for casement and sliding shutter and frame;2) Glazing clips for receiving infill panel; 3) Best quality wool pile where ever shutter touches the frame and compatiblemicrowave cured EPDM rubber; 4) Dash Anchor fasteners of HILTI HRDUGT or equivalent for fixing the frame assembly to the RCC or masonry surfaces. Minimum 1 anchor fastener shall be used for every 600 mm length of section for stability of frame. 5) 10mm GI tie rod for connecting vertical stile at top and bottom for aluminum door shutter and 4mm thick solid aluminium corner cleat of full thickness of sectionfor connecting style and horizontal rails; 6) providing and fixing packing (rough ground) in full periphery/ at every 600mm c/c with average 6 mm thick PVC spacer/ compact sheet of width (equal to section width less 30mm for backer rod and sealant); 7) Filling the gap between wall and frame on both sides (outside and inside) with polyethylene baker rod of avg. 10 mm thickness of approved make and color and then sealing the remaining gap with neutral grade G/M (Glazed & Metal) weather silicon sealant of approved make and color. 8) Termite treated seasoned teak wood as infill material to installe hardware in door shutter and frame as and when required.and excluding the cost of necessary hardwareand Glazing or Infill material. 169 Providing material and labour for fixing 6mm thick Clear Toughen Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid. 170 Providing material and labour for fixing 8mm thick Clear Toughen Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid. 171 Providing material and labour for fixing 10mm thick Clear Toughen Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid. 172 Providing material and labour for fixing 12mm thick Clear Toughen Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid. 173 Providing material and labour for fixing 6mm thick Wired Glass including 1 mm thick ss wire @ every 1 cm horizontal & verticalof any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing with EPDM quality rubber/ silicon sealant/ structural sealant on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Architect. Actual installed quantity shall be measured and paid. Rate shall be inclusive of all type of wastage. 174 Providing material and labour for fixing factory made and pressed laminated 35mm thick flush door shutter of specificied thickness made of ISI marked non decorative type flush door shutters confirming to IS- 2202 (Part 1), core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains orcrossbandsandfaceveneers(IS 710 Grade) onbothfacesof shutters having 1 mm thick decorative type laminates of approved make, shade, finishonbothfacesofshutterfixedwithphenol formaldehyde synthetic resin type adhesive conforming to IS 848 including providing and fixing external lipping with 2nd class teak wood battens, exposed (37mm x 12mm)/ concealed (35mm x 12mm) on all edges of door shutter as requiredwith 2 coats of synthetic enamel painting including 1 coat of wood primer & lapi/ lacquer polishing with primer to all exposed side of lipping, all as per approved drawing, for all floor, all level all height etc. complete as directed by Engineer-in-charge. Measurement including lipping shall be considered for payment. Necessary hardware like hinges, pivot, handle, tower bolts, locks etc shall be separately measured and paid in the relevant tender items. Cost of laminates shall be paid in relevant tender item. 175 Providing material and labour for fixing 1 mm thick Laminate sheet of any size, any shape, any color, any texture of approved make and as per approved sample(approved by architect) on Non decorative flush door, panelling work, fixed partition, any ply surface etc with necessary nails, screws, adhesives as per drawings and as per approved sample. The rate shall be for all heights, all floors, all places etc complete as directed by engineer in charge.Actual laid area shall be measured and paid without considering any westage. Laminates and ply shall be factory pressed. 176 Providing material and labour for fixing 6mm thick frame less mirror of approve make in any shape and sizes as per drawing. Mirror shall be fixed on 6mm thick cement bonded particle board (Bison panel) backing. Cement bonded particle board shall be fixed to wall with approved SS 304 fastener. All edges of glass shall be grinded (as required), cute corner and polished. Glass shall be fixed with silicon sealant/ 3M tape etc complete at all floors/ all levels/ all heights as directed by engineer in charge. Installed area of mirror shall be considered for payment without wastage. 177 Providing material and labour for Extra charges for machined Perforation of required dia and pattern in flush door shutter/ compact sheet of any thickness for air circulation for all floor, all height all level as per drawing and as directed by Engineer in charge. Edges of perforation shall be finished and sharpen. 178 Providing material and labour for fixing SS 316 grade butt hinge of average 100 x 64 x 2.5 mm - without ball bearing of approved make as per approved sample with necessary screws etc. complete for all floor all height all level as directed by Engineer in Charge. 179 Providing material and labour for fixing set of dead lock of approved make with 50mm backseat, 20mm square for end with 72 mm centers including strike plate in satin stainless steel finish as per DIN 18251-1, grade 2 and prepared for euro profile cylinder (EPC) including strike plate and EPC length 60/70 mm standard Euro profile Pin Cylinder/ Half pin cylinder with both side key/ one side key one side knob operation with one pair of SS 316 grade Escutcheons (key hole plate) for wooden/ aluminium/ metal doors with necessary SS Phillips head screws etc complete for all floor, all level, all height as per approved sample and as directed by engineer in charge. The lock shall be with 3 keys. 180 Providing material and labour for fixing SS 316 grade push-pull pair of handle of size300 mm long x 22 mm dia made out of satin (brush) finish hollow pipe of 1.5mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved makewith necessary screws etc. complete forwooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle should be perfect center to center as below specified. 181 Notes for Hardware : Supplying and fixing heavy quality fixtures and fittings for doors, windows, ventilators, partition wall, cabinets with necessaryscrews, nails, machine pins etc at all floor/ all levels/ all heights complete. Sample shall be approved by Architect before execution. As per description, SS hardware shall be of 304 grade or 316 grade as per item description and as per approved sample. The fixture & fastenings shall be provided as under :Providing material and labour for fixing single/ double action hydraulic floor spring with SS cover plate & adjustable concealed casted top pivot (two piece) and bottom strap of approved make for wooden/ aluminium doors of specifiedcapacitywith minimum one year guarantee. Rate shall be inclusive of cutting of floor neatly, grouting the floor spring & cleaning/ polishing the floor & maintaining in good working condition until defect liability period. In case of Aluminium shutter bottom arm of floor spring & top pivot shall be firmly fixed in the aluminium members using required size of teak wood by making rabbet in the wood. The Floor Spring shall conform to EN 1154. a) Hold open having for shutter width upto 1200mm with standard spindle and cover plate. Closing force complying with EN 1154 2-4 182 Providing material and labour for fixing SS 316 grade handles 150mm long D shape hollow tube handle of approved make with both end bracket with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. 183 Providing material and labour for fixing of SS 304 grade brush finish 450mm height Tower bolt (barrel type with minimum rod size shall be 10mm) of approved make in wooden doors/ aluminium doors/ metal doors with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. 184 Providing material and labour for fixing of SS 304 grade brush finish 250mm height Tower bolt (barrel type with minimum rod size shall be 10mm) of approved make in wooden doors/ aluminium doors/ metal doors with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. 185 Providing material and labour for fixing SS 304 grade brush finish solid Door bufer with pvc base, wall mounted (square/ round) of approved make with necessary screws etc. complete as approved by Engineer-in-charge in Charge. 186 Providing material and labour for fixing vision panel made out of 5mm thick clear toughen glass of any shape any size in all type/ thickness of flush doors shutter. Glass shall be fixed with teak wood lipping (Lacquer polished of approved make and shade) on both side the door of required size as shown in drawing and direction of Engineer-In-Charge. Rate shall be includes the cost of cutting door, provision of glass with both side polished lipping, making good etc complete. The actual installed area of vision panel shall be measured for payment. 187 Providing and fixing of Non Fire rated Hollow metal door of approved make and shade at all levels from ISO 9001-2000 certified Manufacturer. All hollow metal general doors with or without vision panel. Pressed Galvanized steel Single /Double leafto required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be Double rebate profile of size 143 x 57 mm made out of 1.20mm thick galvanized steel sheet (18 gauge). Frames should be Mitered and field assembled with self tabs. Frames should be fixed with back plate bracket and anchor fasteners of approved size and make for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement slurry if recommended on the clear masonary opening.Door leaf should be 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 0.8mm (22 gauge) minimum thick galvanized steel sheet. The internal construction of the door should be rigid with steel stiffeners/ pads and reinforcement. The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be as per joinery details with a screw on glass beading on the inside. The glass should be 5mm clear toughened glass. Shutter shall be fixed to frame with SS 304 Ball Bearing Butt Hinges of size 100mm x 75mm x 3 mm (no of hinge as suggested by engineer in charge).All door shutter and frames shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate shall be include supply and installation of door i.e frame, anchor fastener, shutter with vision lite, hinge but exclude the cost of hardware (other than hinge) etc complete as directed by engineer in charge. Out to out area of door with frame shall be measured for payment. 188 Sec.7.0 Plastering & Pointing worksProviding material and labour for laying 10mm thick mala cement plaster in single coat onceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for all floor, all level, all height(including all basement) with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge. 189 Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand) for for all floor, all level, all height(including all basement) with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge. 190 Providing material and labour for laying 20 mm thickinternal/ external double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished for all floor, all level, all height(including all basement) with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge. 191 Providing material and labour for laying 20mm thick sand faced cement plaster on walls upto height 10metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge. 192 Providing material and labour for fixing G.I. hexagonal chickenmesh of size 20mm x 20mm of 22 gauge at junction of concrete and brick work or between different materials after making V grove between two different material surface and filled with rich cement mortar and@ 100mm on each side of surfaces including necessary U nails/ screws/ washers with cleats for fixing, overlaps, curing, scaffolding etc complete for all floors/ all levels/ all heights/ all shapes as per direction of Engineer-in-charge. 193 Sec.8.0 Waterproofing works Providing material and labour for laying integral cement based water proofing treatment (India type brick bat) including preparation of surface as required for treatment of roofs, balconies, terraces etc with average thickness of 120 mm and minimum thickness at khurra as 65 mm and consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in- charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with wired finish to receive china mosaic flooring.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge for all height all level. 194 Sec.9.0 Flooring worksProviding material and labour for laying average 25mm thick machine cut semi mirror polished Green Kota stone slab of size upto 600mm in flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including curing, rubbing and polishing at all floors any heights, any lead and lift in any shape and pattern etc complete as directed by Engineer In charge.Sample shall be approved before execution. Kota stone shall be in uniform shade of reuired size. Sample and mockup shall be approved before procurement of material. 195 Providing material and labour for laying 8 to 10 mm thick Kota stone slabs in upto 100mm high skirting, (flush with plaster) laid on average 10 mmthick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including providing 10mm wide grove between skirting and plaster, rubbing and polishing complete as directed by Engineer In charge. Sample shall be approved before execution. Kota stone shall be in uniform shade of reuired size. Sample and mockup shall be approvd procurement of material. Shade of skirting must be match with flooring stone. 196 Providing material and labour for laying average 30 mm thick machine cut both side polished Green kota stone slab of size upto 1.5mt length for shelves, counter, partition in walls, self, etc as per drawing of stair over 12 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with gray cement slurry including polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. The rate shall be inclusive of making rebates of 10x10mm for forming the grooves between treads and risers with polishing inside the groove. Sample shall be approved before execution. Sample and mockup shall be approvd procurement of material. 197 Providing material and labour for laying average 40 mm thick machine cut polished Green kota stone slab of size upto 0.9mt length with uniform thickness double side polished at edges for parapeet wall coping, window sills, over 20 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry or stone fixing adhesive and mechanical fastner of approved make including roundingof exposed edges, polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. All Expose edges of stone shall be pencil sharped and in even thickness and polished at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge. Sample shall be approved before execution. Sample and mockup shall be approvd procurement of material. 198 Providing material and labour for laying cement concrete pavement (of any thickness) with 1:2:4 (1-cement : 2-coarse sand : 4-stone aggregate 20mm nominal size) including curing, finishing with floatingcoat of neat cement complete at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge. 199 Providing material and labour for laying 8 to 10mm thick full body vitrified tile of size upto 600mm of any shade, any finish (glossy, matt, satin or anti skid finsh) of approved make in flooring and Skirting laid over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) and fixed with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including provision of groove, grouting of joints, finishing of joints, curing etc complete for all floors any heights, any lead and lift as directed by Engineer In charge. Grouting shall be paid in relevant tender item. Sample and mockup shall be approvd procurement of material. Actual laid area of tile shall be measured and paid. 200 Providing material and labour for laying 8 to 10mm thick,double charged Vitrified tiles of size upto 600mm (of any shade glossy, matt or satin finsh) of approved make, shade and finish as approved by Architect/ EIC for all floors/ any height/ any levels etc in wall tile, dado, risers of steps, jambs as per drawings. Wall tile is to be fixed over 10 to 12 mm thick smooth finish plaster in cement mortar 1:3 (1 cement : 3 coarse sand) and fixed with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including provision of groove, grouting of joints, finishing of joints, curing etc complete for all floors any heights, any lead and lift as directed by Engineer In charge. Grouting and backing coat plaster shall be paid in relevant tender item. Sample and mockup shall be approvd procurement of material. 201 Extra for providing material and labour for Grouting the joints of any type of flooring tiles of Size upto 600mm having joints of 3mm width and in full depth, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade and approved make (0.10 kg of hardener and 0.20 kg of resin per kg), including filling/ grouting and finishing complete as per direction of Engineer-in-charge. 202 Providing material and labour for fixing average 18mm thick mirror polish Granite of uniform size and colour for treads and risers of stair, sill, jams of window, coping etc size 1200mm to 2500 mm long, of approved shade, including necessary machine - cut edges (uniform thickness) rounded edges, as per design in required sizes and shapes over 20 mm (average) thick bedding of cement mortar 1:6 (1 cement: 6 coarse sand) laid and jointed with white cement and matching pigment including rubbing, re-polishing after fixing to remove any undulation between the joints (if required) with different grades of Emery, refilling of open joints, curing, daily cleaning and mopping, as directed for at least 15 days or up to the satisfaction of the EIC etc complete for all floors any heights, any lead and lift as per approved sample by Architect, drawings and instruction of EIC.The rate includes machine cut edges of uniform thickness, champhering and mirror polishing of edges and maintaing upto hand over the project. 203 Providing material and labour for fixing mirror polished average 18mm thick best quality Granite stone slab as per sample approved by Engineer in charge with edges rounded and mirror polished, of required size fixed as platfrom/ vanity counterby cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement mortar 1:2 (1 cement : 2 coarse sand) as per drawing and as per direction of Engineer-in-charge. 75mm high facia shall be fixed at the edge of platform with epoxy or stone fixing adhesive as per drawing. All expose edges shall be champhered and mirror polished. Rate shall be inclusive of chasing, cutting, pencil sharped edges, edge polishing, making holes, curing, finishing, maintaining upto handling ovre the projectetc complete for all floors all level etc complete as directed by Engineer Incharge. Installed area of platform and facia shall be measured for payment. 204 Providing material and labour forlayingbrokenchina mosaic flooringfor terrace using 12 mm to 20 mmbroken pieces ofglazed tiles (of any shade) to be laid over cement mortar 1:3 to plain or slope andtobe temperedtobring mortarcremeout uptosurface using white cement including rounding off junctions and extending them upto 15 cm along the wall, curing, clearing with water and oxalic acid etc for all level, all height as directed by engineerin charge. 205 Providing material and labour for laying Cement Mortar for additional floor bedding in Cement Mortar 1:6(1-Cement: 6 - coarse sand) including curing etc for all floor, all level all height. Additional bedding thickness shall be as per drawing and as directed by engineer in charge. 206 Sec.10.0 Structural steel worksProviding material and labour for, fabricating, assembling, hoisting/ erecting and fixing in position at all heights/ all levels/ all floors/ all shapes & sizes with all leads & lifts using MS Rolled Steel Sections, Hollow sections, Tubular Sections, MS Plates, Chequered Plates, MS Pipes, Perforated Sheet, Flats,Bars , Angles, MS Sheet, Girder, Beam, cattle trap, deep threaded MS bolts, threaded J bolts, insert plate, support plate etc as per drawing. all confirming to latest relevant IS codes for the work of steel structures like staircases, railings, handrail, jali, gates, grills, bracings, platforms, brackets, monkey ladder, cattle trap, rungs, false ceiling frame work, Roof canopy, fencing posts, M.S. Screen & fencing jali frame work etc. including straightening, cutting, bending, bolting and welding the members all as per approved shop drawings and as per detailed specifications (for materials & workmanship) including necessary scaffolding/ staging etc. complete and comprising of Profile Cutting, Smooth grinding/ machining of edges/ faces/ all welding joints; Necessary welding; Machine drilling of holes for joining/ anchoring; dry sanding, degreasing (wet cleaning) & preparation of rustfree surface manually or mechanically, metal putty to make the surface even and smooth, 1 coat of epoxy primer and2 coat of PU paintof approved make shade of paint over all the surfaces of the steel sections.The Contractor shall prepare shop drawing as per GFC drawing and as per actual site condition and get approved before execution by engineer in charge. (Standard measurements will be paid for as actual cut length used at site) 207 Providing material and labour for fixing rolling shutters of approved make made of 80 mm wide M.S. laths inter-locked together through their entire length and jointed together at the ends by end locks mounted on specially designed pipe shaft with bracket plates, guide channels and arragements for inside and outside locking with push-pull operation including the cost of hood cover and spring, 1 coat of Yello zinc chromate primer and 2 coat synthetic enemel Paint of approved make and shade over all the surfaces etc. complete for all floor all height as directed by Engineer in charge.(B) Shutters having width 3.5 M. and above 208 Providing and fixing stainless steel (Grade 316) Railing and baluster system of approved make stair railing, hand rail, bump rail, guard rail, with knock down system made of Hollow or solid secion i.e. tubes, square, flat, plates, bar etc with base plate Cover cap, finishing accessories, infilled holding brackets, fixing accessories etc. for any type of design, shape (plain/ curvature), size as per drawing. Railing shall be top mounted or side/ wall mounted. Railing shall be fixed with SS 316 grade anchor fastner of required size and as per fixing position of approved make. No Welding OR Fabrication shall be allowed at site.(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Sample shall be approved before execution. Contractor shall arrange mock up of railing system (2 or 3 no) in required length as directed by Architact and Engineer in charge. Contractor shall protact railing system uptill handeling over the project. 209 Extra for providing material and labour for Hot dip galvanizing work confirming to IS 4759/ 2629/ 2633 with zinc of 610 GSM thickness on Cable tray, Railing, Handrail, facade framing, supports for mechanical equipments, garbage box, Street furniture and similar works etc made from solid flat, bar, RHS, SHS, tubular hollow sections etc. as per the drawing and as instructed by engineer in charge. The rate shall include preparing the surface by shot blasting/ acid washing prior to hot deep galvanizing, labor, tools, machinery etc complete (Sample to be approved).The weight of steel sections before galvanization shall be measured for payment. The cost of steel sections shall be paid for separately under relevant item. 210 Sec.11.0 Painting worksProviding material and labour for applying (Synthetic) Plastic emulsion paint (minimum 2 coats) having VOC (Volatile Organic Compound) content less than 50 gm/ltr on newly/ existing dry interior plastered surface including ceiling, roof etc. at all heights/ all levels/ all surfaces to give an even shade on prepared (putty and primer work) surfcae. Sample to be approved before starting of the work by Architect/ EIC. Rate shall be inclusive of the cost of scafolding but excluding the cost of primer and putty work. 211 Providing material and labour for applyingrequired coats (min two coats) of white cement based putty after thoughly brushing the surfaces free from mortar dropping and other foreign matter. Preparing the surface even and sand papered smooth, after applying every coat of putty complete. Priming coat of alkali resistant cement primer (water or solvent based) is to be applied over prepared smooth surface (undulation free) etc. complete as directed by engineer-in-charge. After application of putty work, wall surface shall be in levelled and without undulation. The rate shall include the cost of filler for filling the cracks on surface, thoroughly brushing the surfaces with sand paper to make it free from mortar dropping and other foreign matter, scaffolding etc. as directed by engineer in charge. 212 Providing material and labour for applying Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials etc complete for all floors, all heights, all level as directed by Engineer Incharge. Product to be 213 Sec.12.0 Roofing worksProviding material and labour for fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weightcalcium silicate ceiling tiles shall have, light reflection 85% non-combustible as per BS 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC for the best thermal Insulation. The Light weight calcium Silicate tile shall be of approved texture of size 595 x 595 x 15 mm to be laid on true horizontal level suspendedinter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross‘T’ of size 24x28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced between main ‘T’ at 600mm centre to centre to form agrid of 1200x600mm and secondary cross ’T’ to be interlocked at middle of the 1200X600mm panel to form grid of size 600x600mm resting on periphery walls/ partitions on a perimeter wall with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick Densified edges light weightcalcium silicate ceiling tiles in the grid including, cutting /making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required, Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized steel level clips of size 85X30X0.8mm, spaced at 1200mm centre to centre long main ‘T’ bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint,as per specifications, drawings and as directed by engineer-in-charge. 214 Providing material and labour for fixing fabricated metal single shutter/ double shutter trap door made from 0.8 mm MS sheet, Inner Frame - 1.5 mm, Outer Frame - 2mm MS sheet andfinished with powder coating of approved shade/ enamel/ acrylic paint (primer + 3 coats of paint) of approved make and shade. Door shall be installed on existing false ceiling framing with extra MS suspender with necessary hardware like allen key lock, hinges/ pivot, safety chain etc complete as directed by engineer in charge.Rate shall be inclusive for providing, loading/ unloading, transporting and installation at all floor all height but excluding the cost of extra suspender for installing the trap door. Area of trap door with frame shall be measured for payment. 215 Fiber cement board :Providing material and labour for fixing exterior grade cement fibre board/ plankcement pattas of 8mm thickness at exposed concrete ceiling/ wall/ beam bottom with brass/ SS head screws as per drawings, specification and sample approved at all floors, all levels and all shapes etc complete as directed by engineer in charge. Rate shall be inclusive of all material, labour, scafolding, tools, tackes etc complete. 216 Sec.15.0 General Development and Road worksProviding and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm PVC couting on outer side including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. 217 Providing material and labour for laying cement concrete broom finish/ smooth finish pavement for plinth protection/ CC Road 100 –150 mm. thick with M25 concrete including giving a floating coat of 1:1 cement mortar, with Nominal temperature steel, tie bar, dowel bar as per MORTH specifications of section -6etc complete as specified by the Engineer-in-charge. The rate shall be exclusive of reinforcement steel, dowel bar etc. The same shall be paid in relevant tender items. Rate shall be inclusive of concrete (to be laid in alternate panels size shall be apprx 4.5mt X 5.0mt ) with fair finished steel channelformwork, saw cutting of construction & contraction joints in width 3 to 5 mm x 1/4 to 1/3 thickness of pavement, filling the 25mm x 20 mm (BXD) expansion joint approximately at every 30 mt with readymix bitumiNous filler as per sample approved & directed by engineer incharge etc complete. Screened Sand to be only used. 218 Vaccum dewatering Extra for carrying out vaccum dewatering & Power floater treatment in roads, pavements, floors well compacted, mechanically vibrated with screed vibrator, finished to required levels, floated with neat cement and power trowelled to get desired smooth finish / broom finish, over a leveling course, including MS channel or box shuttering, curing for 10 days with gunny bags etc complete. The size of panel should be approximately 3.75 x 5.5 m or as directed by Engineer. The Contraction joints to be formed at every 5m distance by grooving with mechanical saw within 48 hrs. Groove/sawed joints/ longitudinal joints shall be made of 6mm width and 25 mm depth min (1/3 rd depth of the pavement) as shown in the drawing. The rate shall be inclusive of labour, making the grooves and machinery cost. 219 Providing and fixing high quality FRP gratings of size 40mm x x40mm x 30mm high having the load tested as per BSEN 124, IS1726 & AASHTO M306 standards of approved make and shade. Grating shall be directely fixed on wall of RCCchannel as per drawing and as directed by Engineer in charge. Actual installed area of grating shall be meaured for payment with out considering any wastage. 220 Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge. 221 Providing material and labour for fixing G.I. barbed wire Fencing on existing MS postprovided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs etc for all height all level as directed by Enginer in charge. (cost of MS posts to be paid for separately)Payment to be made per metre cost of total length of barbed wire used. 222 Sec.16 Signage WorksACP sheet signage :Providing, Making and fixing 3 mm thick ACP sign of any shape and size and of approved make to be cut on CNC router cutting and smoothen all corners and edges. Matter shall be cut in 3M High intensity prismatic Reflective vinyl ASTM Type 4 and paste on it as per design and detail and as per manufacturers specifications. UV stabilized lamination shall be done on it. The ACP sheet shall be fixed with clamp and angle on new or existing MS Pole as per drawing.Content of sign shall be letters (In Gujarati & English), graphics / maps, signs etc. in any colour as per design, drawing and approved by Architect and Engineer. All side of box shall be covered with fresh ACP sheet, but only one side elevation area shall be measured and paid in sqmt. Cost of MS Pole and Civil works shall be paid as per relevant tender items. The rate shall also include cost of scaffolding, drilling, fabrication, finishing, adhesive material, etc at all height and all lead, angle, fixing charges, etc. The contractor should submit the drawings based on concept design and do the sampling and get it approved before execution. 223 Surface/ wall mounted signsProvidng and fixing of Modular Signages using Aluminium extrusions (Alloy 6060) with Anodizing (Thickness 15-20 microns).ISO:9001-2008 product with Premium grade Anodizing as per Qualanod and Qualicoat International standards. Internal graphics to be made of 3M vinyl printed with Hp latex 3rd Gen Eco friendly non toxic inks with UV lamination and 2 year print warranty.Sign panel shall be finished with anti-reflex cover 1mm thick with one side Matt and other side Glossy finish. Polypropylene (PP) End caps which can be fixed to the extrusion with the help of screws. Panels shall be clicked on to the end caps.Aluminium framing shall be fixed on surface with SS 304 screw and signage pabnel shall be laid on aluminium framing as per manufacturers specification. Rate shall be inclusive of total modular signage system for all level, all height etc complete as directed by engineer in charge. Sampe shall be approved before execution and mockup shall be done with approved sample for 2 to 3 number of signage. 224 PLUMBING WORKSSection 1: Water SupplyProviding and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. Internal Work - Exposed on wall - 18.1.1 - 1216 (16mm OD) pipe 225 Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. Internal Work - Exposed on wall - 18.1.2 - 1620 (20mm OD) pipe 226 Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. Internal Work - Exposed on wall - 18.1.3 - 2025 (25mm OD) pipe 227 Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. Internal Work - Exposed on wall - 18.1.4 - 2532 (32mm OD) pipe 228 Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. Internal Work - Exposed on wall - 18.1.5 - 3240 (40mm OD) pipe 229 Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the Engineer-in-charge. Concealed Work, including cutting chases and making good the wall etc. - 18.2.1 - 1216 (16mm OD) pipe 230 Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the Engineer-in-charge. Concealed Work, including cutting chases and making good the wall etc. - 18.2.2 - 1620 (20mm OD) pipe 231 Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the Engineer-in-charge. Concealed Work, including cutting chases and making good the wall etc. - 18.2.3 - 2025 (25mm OD) pipe 232 Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the Engineer-in-charge. Concealed Work, including cutting chases and making good the wall etc. - 18.2.4 - 2532 (32mm OD) pipe 233 Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the Engineer-in-charge. Concealed Work, including cutting chases and making good the wall etc. - 3240 (40mm OD) pipe 234 Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the Engineer-in-charge. Concealed Work, including cutting chases and making good the wall etc. - 4050 (50mm OD) pipe 235 Providing and fixing chlorinated polyvinyl chloride (CPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge.Make: Astral / Supreme / Ashirvad. a) 15 mm nominal bore 236 Providing and fixing chlorinated polyvinyl chloride (CPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge.Make: Astral / Supreme / Ashirvad. a) 20 mm nominal bore 237 Providing and fixing chlorinated polyvinyl chloride (CPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge.Make: Astral / Supreme / Ashirvad. b) 25 mm nominal bore 238 Providing and fixing chlorinated polyvinyl chloride (CPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge.Make: Astral / Supreme / Ashirvad. c) 32 mm nominal bore 239 Providing and fixing chlorinated polyvinyl chloride (CPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge.Make: Astral / Supreme / Ashirvad. c) 40 mm nominal bore 240 Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) / XLPE insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class O insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights.a) For 15mm diameter pipes 241 Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) / XLPE insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class O insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights.a) For 20mm diameter 242 Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class O insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights.b) For 25mm dia pipes - 19mm x 28mm Nitrile Rubber Plain Tubing 243 Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class O insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. c) For 32mm dia pipes - 25mm x 35mm Nitrile Rubber Plain Tubing 244 Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class O insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. d) For 40mm dia pipes - 25mm x 42mm Nitrile Rubber Plain Tubing 245 Section 2: SanitaryProviding and fixing white vitreous china extended wall mounting water closet of size 530 x 330 x 390mm of approved shape including seat and cover, nuts, bolts, and gaslets etc complete. Make: Hindware - Flora / Jaquar - Florentine / Cera - Campbell Clear Rim. 246 Providing and fixing UPVC SWR WC Connector 130 x 110 mm dia. Socket type of approved make, fixed to outlet gaskets with UPVC Lubricant or Solvent Cement, allcomplete as per directions of the Engineer-in-charge. Make: Astral; Model No. F172005909 or Equivalent. 247 Providing, fixing, testing & commissioning of Concealed cistern with frame with dual flush 3/6 ltr with wall flush plate of approved make including push fit flexible hose complete including cutting and making good the walls where required complete as directed by Engineer-in-charge. 248 Providing and fixing Flat Back Large Urinal or approved quality including conecting the Urinal with waste pipe , tap etc. complete.(A) White vitreous China flatback large urinal size (355 to 420)mm x (240 to 395)mm x (535 to 635)mm. Make: Hindware - Eureka / Jaquar - URS / Cera - Carmina. 249 Providing and fixing countertop / table top wash basin having 15mm single hole in the middle for faucet fitting and 38mm hole in the bottom of the bowl for grid drain, cutting and making good the holes in the counter / table top wherever required: (i) White Vitreous China Counter Top / Table Top Wash Basin size (450 to 550) x (300 to 470) mm. 250 Providing and fixing wall mount wash basin with C.I. brackets, 15mm C.P. brass pillar taps, including painting of fittings and brackets, cutting and making good the walls wherever required -Size 660x460 mm with a single 15mm C.P. brass pillar tap 251 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen Sink without drain board: Size: 510 x 430mm bowl depth 200 mm. 252 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. 17.69.2: Waste coupling 38mm dia of 83mm length and 77mm breadth, weighing not less than 60 gms. 253 Providing and fixing PTMT Bottle Trap for wash basin and sink, of approved quality and colour. 17.70.2: Bottle trap 38mm dia single piece moulded with height of 270mm, effective length of tail pipe 260mm from the center of the waste coupling, 77mm breadth with 25mm minimum water seal, weighing not less than 263 gms. 254 Providing and fixing 32mm CP Brass Full Thread Waste Coupling for wash basin, of approved quality and manufacturers standards. Waste Coupling: 32mm dia of 83mm length, weighin not less than 60 gms. 255 Providing and fixing CP Brass Bottle Trap for wash basin, of size 250 x 190mm or nearabout, of approved quality and model. Bottle trap 32mm dia with height of 250mm, effective length of tail pipe 190mm from the center of the waste coupling, 77mm breadth with 25mm minimum water seal. 256 Providing and fixing ABS Chrome plated Brass Hand Shower(Health Faucet) ofapproved make and quality and as approved by Engineer - In - Charge, including 8 mm dia, 1 Meter long Flexible tube & wall hook including cutting and making good the walls wherever required complete as per directions of the Engineer-in-charge. 257 Providing and Fixing 15 mm dia. Wall mounted type CP brass pressmatic bib cock with Auto Closing System with Built-in Control Cock With Wall Flange complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia. 258 Providing and fixing of 15mm nominal bore CP Brass Angle valve confirming to IS: 8931, for wash basins, water coolers, geyser points, etc of approved quality and as approved by and directed by the Engineer-in-charge. 259 Providing and Fixing 15 mm dia. CP brass two way bib cock with wall flange and ceramic disc cartridge complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia. 260 Providing and Fixing in position CP brass Pressmatic Urinal Flush Valve Auto-closing system with built in Control Cock and Wall flange of approved or equivalent make, including 15mm S.S. pipe connection with Urinal and Urinal Spreader, and including all necessary materials required for fixing. All complete as per directions of the Engineer-in-charge. 261 Providing and Fixing 15 mm dia. CP brass bib cock with Wall Flange complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia. 262 Providing and Fixing 15 mm dia. Wall mounted type CP brass Sink cock with Wall Flange complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia. 263 Providing and fixing SS Toilet Paper Roll Holder with Flap including SS screws & Rawl Plugs, complete as per approved make and as directed by the Engineer-in-charge. 264 Providing and fixing SS Liquid Soap Dispenser with metallic bottle having 250ml liquid holding capacity of approved make and quality and as directed by the Engineer-in-charge. 265 Providing and fixing U.P.V.C (Type B) conforming to IS 13592, & fittings conforming to IS 14735 of approved make Multi Floor Trap Height Riser with 50mm x 50mm x 75mm inlet x 110mm dia outlet, as per specifications & at all levels & at all heights, as approved and directed by Enigeer-in-charge. 266 Providing, laying and jointing in true line and level 160 mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 160 mm diametre x 210 mm length x 196 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. 267 Providing, laying and jointing in true line and level 110 mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. 268 Providing, laying and jointing in true line and level 75mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to IS 14735 of approved make for drainage system pipe line,pipe shall be jointed with each other with rubber lubricant, pipe shall be shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. 269 Providing, laying and jointing in true line and level 50mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to IS 14735 of approved make for drainage system pipe line,pipe shall be jointed with each other with rubber lubricant, pipe shall be shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. Pipe length per piece: 1.8 Mtrs 270 Providing, laying and jointing in true line and level 40mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to IS 14735 of approved make for drainage system pipe line,pipe shall be jointed with each other with rubber lubricant, pipe shall be shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. 271 Providingand fixing unplasticized PVC SWR as per IS: 13592 (Type B), P - Trap as approved and directed by the Engineer-in-charge. For 110 mm Dia pipe 272 Providing and supplying ISI mark G.I. Pipes with couplings of following class and diameter including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading unloading, conveyance to the dept. stores etc. complete: (IS - 1239) (For CSSD Drains) Medium Duty: 100mm diameter 273 Providing and supplying ISI mark G.I. Pipes with couplings of following class and diameter including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading unloading, conveyance to the dept. stores etc. complete: (IS - 1239) (For CSSD Drains) Medium Duty: 80mm diameter 274 Providing, laying and jointing in true line and level 150 diametre U.P.V.C (Type A) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735 of approved make for drainage system pipe line,pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. 275 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes at an average distance of 1.2 meters centre to centre, by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 276 Sec.5.0 MECHANICALSHydro-pneumatic System - for Hot Water - at Laundry Terrace:Supply, Installation, Testing And Commissioning of Compact Self Contained Skid Mounted Hydropneumatic System as follows: Design, engineer, procure, supply, test and commission a pre-engineered, factory fabricated, assembled & tested, fully integrated, highly efficient pump, IE3 motors, skid mounted, complete ready-to-connect packaged fixed speed water pressure booster station. The packaged fixed speed water pressure booster station shall be complete with vertical multi stage centrifugal pumps connected in parallel, high efficiency IE 3 motors, intelligent multi-pump controller, the controller shall be mounted in a control cabinet with an IP 67 enclosure of suitable rating having Potential free contacts to monitor On/Off & Trip status with necessary sensors/switches; Stainless Steel (SS 304) suction and delivery manifolds; isolation ball valves on suction and discharge of each pump; non return valve on discharge side of each pump; hot dip galvanised common base frame; and diaphragm pressure vessel. Complete (Skid mounted / wall mounted / floor mounted) electrical control panel comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiringand any other necessary imports etc. (list to be provided by the vendor). All installations such as electrical wiring from Electrical Panel to Pump panel, civil foundations, etc is included in this scope. Set of accessories such as NRVs, isolating valves, Stainless Steel SS 304 suction and delivery header, pressure gauge, MS Epoxy coated base frame, pressure switches, pressure transducers, inter connecting power and control cabling etc. complete.For Hot Water: Hot Water Supply - Set consisting of 2 pumps (1 working + 1 standby); Flow Rate (System): 150 LPM (9 Cu. Mtr / Hr); Pressure Vessel = 1 x 100 Ltrs; Head (each pump): 25 Mtrs. 277 Electric Geysers: Supplying and erecting horizontal / vertical mounting type storage water heater with copper container housed in M.S./S.S. body insulated with glass wool / puff complete with heating elements,adjustable thermostats 300 c to 850C, indicating lamp, safety valve, fusible plug, etc.complete erected with coach bolts, nuts. washers& cementation. (B)15 Ltr-.with 2 /3K.W. heating element - Premium CategoryMake: Racold or Similar or Equivalent of an approved make. 278 Supplying and erecting chromium plated heavy duty brass valve for inlet pipe of water heater 15 mm dia.) 279 Supplying and erecting 15mm brass non-returnvalve for inlet pipe of storage water heater. 280 Supplying and erecting dead pressure releasing valve for storage type water heater with necessary materials. 281 WATER COOLERS:Providing and erecting water cooler having storage capacity 150Ltr. & cooling capacity 150 Ltr.per hour @ an ambient temp of 45 deg. C. The outlet temp. of the water should drop by 15 deg. C within a hour, The water cooler should be comprising of hermetically sealed compressor, fan motor, condensing unit, water tank surrounded by evaporating coil, thermostats, relay etc. complete with necessary inlet & outlet connection. The body of water cooler will be made from Stainless Steel. 282 Supplying & erecting 5 stage single reverse osmosis water purification system with M.S. powder coated frame, prefilter housing with O ring presediment filter GAC filter, carbon filter suitable buster DC pump capacity 80 psi, mention with 40 psi inline type post carbon filter auto low & high pressure switches with following size of storage tank & LPH capacity & erected as directed [C] 50 Ltr / Hr with 150 psi 2 nos booster pump 283 LEVEL SENSORS:Supplying & erecting approved make Automatic liquid level controller 6A.as per instruction of Engineer in charge on site complete with wiring connection with existing wires , with copper conductor from pump to upper and lower tank. 284 DRAINAGE SUMP PUMP:Providing and fixing compact monoblock dry motor submersible pumps of suitable rating, with non-clog free flow open impeller, solid handling capacity of up to at least 30mm suitable for operation on 415 volts +10% , 3 Phase, 50Hz,A.C supply, speed 2900 RPM including oil chamber, guide wire for lifting & lowering of pump, M.S. galvanized lifting chain, duck foot bend complete.The pump setsshall be supplied with required accessories & as per specification with the following : (a) Water level sensing – switch type or hydraulic floats or pressure switch – with data accessible on IBMS platforms.(a) Complete piping 80 mm dia common delivery up to 12 m in heavy Duty Class C G.I. – 10 meters length.(c) 80 mm dia Flap type Forged Brass Non-return valve. – 2 Nos. (d) 80mm dia Forged Brass Gate Valve. – 1 No.(e) Necessary cables from pump set to control panel (10 meters) – 1 Set (f) Electrical control panel having all necessary accessories &safetydevices of standard specifications and suitable for receiving supply cable to connections within, and outlet connections for starters, and earthing outlets, complete. All best standards, as per ECBC & IS Codes to be followed and provided. Starters to be operated on cascading operations, so as to maintain maximum life cycle ofeach pump. – 1 Set.(g) Panels to have Modbus / BACnet connectivity, with pump performance data, pump fault data, On / Off operations, etc to be incorporated.(h) Each set consist of 2 nos. of pumps - 1 working & 1 stand by.Discharge: 25 Cu. Mtr / Hr.Head: 15 Meter (minimum). 285 ELECTRICAL WORKSSection 1: MV switch gear & Power panelSupplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels withpowder coated fabricated fromCRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respectCSSD POWER PANELAs per Single line diagram 286 Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels withpowder coated fabricated fromCRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respectLAUNDRY POWER PANELAs per Single line diagram 287 Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels withpowder coated fabricated fromCRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respectMEDICAL GAS POWER PANELAs per Single line diagram 288 Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels withpowder coated fabricated fromCRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respectPNEUMATIC POWER PANELAs per Single line diagram 289 Section 2: Distribution BoardDISTRIBUTION BOARD Supplying, assembling, grouting, levelling, installation,Connecting,testing and commissioning of D.B of specified make but without MCB / ELMCB/MCCB etc but with all internal busbar as per requirement.SPN Distribution Board :Supplying, erecting, testing and commissioning ofSPN D.B. with space for DPELMCB as incoming and 12 SPMCB as outgoing per phase (i.e. 16 way SPN D.B.) 290 Supplying, erecting, testing and commissioning ofSPN D.B. with space for DPELMCB as incoming and 8 SPMCB as outgoing per phase (i.e. 12 way SPN D.B.) 291 Supplying, erecting, testing and commissioning ofSPN D.B. with space for DPELMCB as incoming and 4 SPMCB as outgoing per phase (i.e. 8 way SPN D.B.) 292 MCB s and its AccessoriesSupplying, Assembling, levelling, connecting testing and commissioning of following MCB / ELMCB / MCCB etc in boards as specified in 2.1, 2.2.Miniature circuit breaker single pole 6A to 25A. suitable to operate on 240V. A.C. system and having breaking capacity 10 KA to be erected in existing box. Confirming to IS 8828 / 1996 with ISI Mark. 293 6A / 10A / 16A /20A / 25ADP RCBO(RCCB+MCB) (30mA) 294 32A / 40ADP RCBO(RCCB+MCB) (30mA) 295 Surge Protection Devices (SPD) Supplying, Assembling, levelling, connecting & testing following VSPs etc in boards as specified in 8.4.19 & 8.4.201.2KV Protection level DP, Class s, (Imax-15KA, 8/20µS) LEGRAND Cat no. 412221 or Equivalent 296 100 A FP MCCB with Sheet steel metal enclouser - ICS=100% of ICU only Cat IIINote:-1 The Enclousers should be used of same company of MCCBs to be used (6290+500=6790) 297 Sheet steel metal enclouser for SP MCB equivalent to Legrand cat No..607881 298 ShSheet steel metal enclouser for DP MCB equivalent to Legrand cat No...607882 299 Sheet steel metal enclouser for FP MCB equivalent to Legrand cat No...607884 300 SITC of Blank Plates 301 Caution Board :SITC of Caution boards of size 150 x 150 mm. to be supplied & fixed on the D.B. 302 Section 2: MV CablingSupply, testingand Laying and commissioning ofXLPEsteel wire/flat armoured cable of 1100 V grade of AluminumConductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.150 Sq.mm x 3.5C Al. Cable 303 Supply, testingand Laying and commissioning ofXLPEsteel wire/flat armoured cable of 1100 V grade of AluminumConductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.95 Sq.mm x 3.5C Al. Cable 304 Supply, testingand Laying and commissioning ofXLPEsteel wire/flat armoured cable of 1100 V grade of AluminumConductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.70 Sq.mm x 3.5C Al. Cable 305 Supply, testingand Laying and commissioning of XLPEsteel wire/flat armoured cable of 1100 V grade of CopperConductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.6 Sq.mm x 4c CU. Cable 306 Supply, testingand Laying and commissioning of XLPEsteel wire/flat armoured cable of 1100 V grade of CopperConductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.6 Sq.mm x 3c CU. Cable 307 Supply, testingand Laying and commissioning of XLPEsteel wire/flat armoured cable of 1100 V grade of CopperConductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.4 Sq.mm x 3c CU. Cable 308 Section 4: Cable TerminationSITC ofBrass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:150 Sq.mm x3.5C Al. Cable 309 SITC ofBrass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:95 Sq.mm x3.5C Al. Cable 310 SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:70 Sq.mm x3.5C Al. Cable 311 SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:6 Sq.mm x4C CU. Cable 312 SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:6 Sq.mm x 3c CU. Cable 313 SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:4 Sq.mm x 3c CU. Cable 314 Section 5: Cable TraySupply, Installation, testing and commissioning of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware :150 x 100 made out of 2 mm thick ladder type 315 Supply, Installation, testing and commissioning of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware :300 x 100 made out of 2 mm thick ladder type 316 Supplying , fabricating and installation of various sizesclamps for cable tray supports using available M.S. sections & rod as per drawings or instructions of engineer in charge or consultant including applying zinc chromate yellow oxide and two to three coats of required enamel paints with anchor fasteners etc. 317 Section 6: Internal WiringWITH MODULAR TYPE SWITCHESWiring of points to be done in open/concealed manner in 25 mm dia medium guage Rigid PVC FRLS pipe. Wiring shall be done with FRLS type copper flexible wire of 650V/1100V. Separate pipe should be taken for circuit mains. Nos of ciruit of the same phases may be taken in same conduit .The circuit shall be laid in 25/40 mm dia medium guage rigid PVC FRLS pipe.The point rate shall include all the necessary piping and wiring from sub panel / Distribution board to switch board & switch board to the batten holder / angle holder / connector / ceiling rose all inclusive except sub panel / Dist board.The wiring shall be done as per relevant prevailing standard. The looping of the wiring should be done in the switch boxes or light and fan point outlet boxes to avoid the junction boxes. The junction boxes and switch boxes for the ceiling light point, fan point etc shall be minimum 60/75 deep. All the necessary jarry in brick plastered walls should be done with machine cutter only , also jarry should be filled with cement, sand and wire mesh as required, the material cost for rough finish shall be included in point rate.Whenever pipes are required to be laid in flooring shall be of.Wiring should be done as per distribtion details. Each circuit should have dedicated phase, neutral & earth wire. Wire sizes to be used as underFor Light Points /fan point/ wall fan / 6A 3 Pin Plug-DB to SB - 2.5sqmm for Phase & Neutral & 1.5 sqmm for Earth- SB to on board Point - 1.5 sqmm for Phase & Neutral & EarthFor 6A Plug point.- 1.5 sqmm for Phase, Neutral & EarthFor 6/10/16A general purpose plug point- 2.5 sqmm for Phase, Neutral & 1.5 sqmm EarthFor 16A plug point for A/C and Geyser- 4 Sqmm for Phase, Neutral & 2.5 sqmm EarthFor 20/32A plug point- 6 sqmm for Phases, Neutral & 4 sqmm EarthNo zarry will be allowed in expose brick work. The conduit shall be provided when the walls are under construction. The pipes in slab shall be laid before the slab is casted.One light point controlled by one single way 6 A switch. 318 Loop light point to be controlled from same switch.(Looping from first point) 319 One light point controlled by two, two way 6 A switch 320 One ceiling fan outlet point controlled by one6 A switch and hum free electronic type step regulator and cast iron fan box. 321 One 6 A x 5 pin 250 Volt universal socket outlet point controlled by one 6 A switch located on switch board. 322 6 A x 5 pin 250 Volt universal switched socket outlet point at convenient location. 323 6/16 A x 250 V switch socketpoint on one switch box with 2.5 sqmm flexible wires and phase and neutral and 1.5 sq nm flexible Cu. wire as earth wire. The rate should include conduiting upto DB. 324 6/16A x 250 Volt switched socket outlet point for Equipmentwith 4 sq.mm wire for phase and neutral & 2.5 sq.mm earth wire. 325 Exhaust fan outlet point with 6A 5 pin socket controlled by one 5 single way switch located at different location. 326 Bell point controlled by Bell push switch withBuzzer / bell of approved make. 327 SITC computer power supply point with 2 nos of 6 amp 5 pin socket with 1 no. of 6/16 Amp. socket with 1 no 16 ASwitch with indicator & wiring of computer point will be done through2 nos.of 2.5 sq. mm Cu. wires as phase & Neutral and 1 nos. of 1.5 sq.mm.as earth wire. .( This cost includes the wiring from DB to Computer point.) 328 20 A x 250 V plug & socket with interlocked switched socket, DP MCB and surface mounting box IP 66 with DIN rail for 2 module legrand make Cat no.56661 or equivalent but without cost of wiring and piping. 329 32 A x 250 V plug & socket with interlocked switched socket, DP MCB and surface mounting box IP 66 with DIN rail for 5 module legrand make Cat no.56669 or equivalent but without cost of wiring and piping. 330 32 A x 415 V plug & socket with interlocked switched socket, FP MCB and surface mounting box IP 66 with DIN rail for 5 module legrand make Cat no.56674 or equivalent but without cost of wiring and piping. 331 METAL CLAD SWITCH SOCKETSITC of Metal Clad Switch Socket with 10A SP MCB (2P+E) 332 SITC of Metal Clad Switch Socket with 20A DP MCB (2P+E) 333 SITC of Metal Clad Switch Socket with 20A FP ELMCB (2P+E) 334 SITC of Metal Clad Switch Socket with 32A FP ELMCB (P+E) 335 MAINSSITC ofmains with 4 nos. of 35 sq mm Cu. PVC insulated FRLS flexible wire withISI approval for 650 V/ 1100 V and 1 nos 16 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 50 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories. 336 SITC of mains with 4 nos. of 10 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 6.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 32 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories. 337 SITC ofmains with 4 nos. of 6 sq mm Cu. PVC insulated FRLS flexible wire withISI approval for 650 V/ 1100 V and 2 nos 2.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories. 338 SITC of mains with 2 nos. of 4 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 4.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories. 339 SITC of mains with 2 nos. of 6 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 4.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories. 340 SITC of mains with 4 nos. of 2.5 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 2 no 2.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories. 341 SITC of mains with 2 nos. of 2.5 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 2.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories. 342 SITC of mains with 2 nos. of 1.5sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 1.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories. 343 ELW 7.00Light Fixtures and FansSupplying and erecting, testing and commissioning of 12W LEDSurfaceMountedDown Lighter-MakeCrompton (LCDSPLN-R-12-CDL) or equivalent as per apporved make list. 344 Supplying and erecting, testing and commissioning of 18WLEDSurfaceMountedDown Lighter-MakeCrompton (LCDSPLN-R-18-CDL) or equivalent as per apporved make list. 345 Supplying and erecting, testing and commissioning of26WLEDRecessed Mounted CircularDown Lighter-MakeWipro (MOLIS LD06-301-XXX-57-XX) or equivalent as per apporved make list. 346 Supplying and erecting, testing and commissioning of 18W LEDrecessedMountedDown Lighter-MakeWipro(18W MOLIS LD06-221-XXX-57-XX) or equivalent as per apporved make list. 347 Supplying and erecting, testing and commissioning of 12W LEDrecessedMountedDown Lighter-MakeWipro(12W MOLIS LD06-151-XXX-57-XX) or equivalent as per apporved make list. 348 Supplying and erecting, testing and commissioning of 36WLED RecessedMounted Square indoor Panel-Make Crompton(LCTLRN-36-F0-CDL) or equivalent as per apporved make list. 349 Supplying and erecting, testing and commissioning of 1x20W 1200mm LEDSurfaceMounted indoor Linear smart Bright Battern Lights Fittings -Make Phillips ( BN021C) or equivalent as per apporved make list. 350 Supplying and erecting, testing and commissioning of 40W LEDSurfaceMountedIndustrailCorroson proof Fixture Ip 65-MakeCrompton (IPFC112LT8-16 2X 20W) or equivalent as per apporved make list. 351 Supplying and erecting, testing and commissioning of 10W LED Wall MountedBulk head Light -Crompton (Type-STUD-LBHP-10-CDL)or equivalent as per apporved make list. 352 Providing and erecting Approved make Ceiling fan with double ball bearingISI mark with condenser A.C. 23OV.50 c/s.1200 mm. sweep complete, canopy erected on existing hook or clamp with earthing. 353 SITC of19/20mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/O. 2 flat 3 core flexible wire with ear thing. 354 SITC ofapproved make low noise decorative exhaust fan having size 200mm with 1350 RPM with square frame.ABS body with inbuilt lowers & square frame. 355 Supplying and erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM. (E)450 mm dai 1400 RPM (CAT-2) 356 SITC of suitable M.S. louver shutter of the Exhaust fan. 357 Section 8: EarthingSupplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipeshaving Outer pipedia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover.(approvedmake OEM has to submit test certificate) & having back filling compound of (B)Inner chemical (CCM Compound)- Resistivity:- 0.2 ?/ meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound:- Earthing compound should be capable to retain moisture for long timeNecessary test report must be submitted. (c) For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA) i.e independent Earthing in normal soil.Length of Pipe : 3.00 mtrs Back filling Compound :2 nosBags of 25 Kg. 358 Earth wire/strips :Supply and laying cu. earthing required size stripsfor interconnecting the earthing stations, panels, DBs etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with :a) Fixing accessories.b) Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes.25 x 3 mm/ 32X6mm / 50x6mm CU. strip/ 38x6 Cu earth link 359 SITCof No.8 gauge bare cu. earth wireComplete in all respect with all reuqired accessories. 360 Section 9: Miscellaneous PVC PIPESSupplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed mannerminimum 25 mm dia with GI pulling wire. 361 Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed mannerminimum 32 mm dia with GI pulling wire. 362 Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed mannerminimum 40 mm dia. 363 Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed mannerminimum 50 mm dia. 364 ELV WORKSSec.1.0 Telephone and Data NetworkingProviding and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceilingerected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed.25 mm 365 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceilingerected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed.32 mm 366 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceilingerected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed.40 mm 367 Telephone / Data Networking CablingSupplying & erecting approved make LAN cable of following size in existing pipe as per direction.[C] CAT - 6 368 Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erectedwith necessary connections as per site situation directed by Engineer In charge.(8)ComputerRJ-45 socket Cat. III. 369 SITC ofJack Panel, fully loaded with 24 nos. UTP ports for PCB based IO Jacks (RJ45, TIA-568C Category-6, Installation and Termination of all 24 nos. Catergory-6 UTP , unloaded with individually replaceable 24 nos. Category-6 I/O Jacks complying with TIA-568.C.2, as per given jack specification Shall be suitable for loading unshielded & shielded jacks for different category systems (CAT 6 & CAT 6A) 370 SITC of company fabricated patch cords shall conform to Cat- 6 & conductor shall be stranded for better flexibility Shallsupport network line speeds up to 1 Gbps Shall have RJ-45 jacks.(A) 1 Mtr 371 SITC of company fabricated patch cords shall conform to Cat- 6 & conductor shall be stranded for better flexibility Shallsupport network line speeds up to 1 Gbps Shall have RJ-45 jacks.(B) 2 Mtr 372 TYPE-2Supplying, installation, testing and commissioning of Layer 2 Fully manageable networking switch, 24 # 10/100/1000Tx ports, all 24 ports shall be capable of providing PoE+ as per 802.3at, minimum 2 SFP+ ports. as per technical specification etc. as required. 373 Supplying, installation, testing and commissioning of10G SFP+Single mode transceiver, 1310nm, 2Km, LC connector, inclusive of any hardware such as modules for populating SM-LC transceivers as per technical specification etc. as required. 374 Sec.2.0 Video Survelance/CCTV SystemSupply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Dome Camera, 1/2.8 CMOS, 2 MP @ 25fps, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, Min. Pixels 1920 X 1080, triple stream, 2.8 -12 mm motorized focus and zoom lens, BLC, HLC, 3DNR, Privacy Mask, IR LEDs Smart IR with upto 50m IR distance, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 2 In/ 1out, PoE, H.264 High Profile and MJPEG, Inbuilt analytics Trigger line/Intrusion/Loitering, PoE Class 3 and 12V DC, IP 67, IK 10 vandal proof, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant with required license as per existing system, as per technical specification etc. as required. 375 Sec.3.0 Fire Detection & Alarm & Digital EVAC SystemSupplying, installation, testing & commissioning of intelligentanalog addressablephotothermal detector having IS-11360-1985 or BS 5446 Part I-1977 & Part VII –1985 (VdS approved) or NFPA72 ( UL/ULC/FM approved) with Latest ammendment complete with mounting base complete as required. 376 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 377 Supplying, installation, testing & commissioning of fault isolator having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment complete with base as required. 378 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of risecumfixedtempreature thermistor having IS-2175 - 1988 or BS-5445 ( EN 54) Part 5 –1977(VdS approved) or NFPA72 (UL/ULC/FM approved)complete with base as required. 379 Supplying, installation, testing & commissioning of addressable fire control module having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment complete as required. 380 Supplying,installation,testing&commissioningof addressable manual call point having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment complete as required. 381 Supplying,installation,testing&commissioningof addressable horn cum strobe having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment complete as required. 382 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000Vratedwithannealedcopperconductorhaving XLPEinsulation,steelwirearmouring&FRLSoutersheath complete as required. 383 Supply, Installation, Testing and Commissioning of 6W Ceiling Speaker with max SPL1M/1W 96dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W and integrate with existing installed systemas per technical specification etc. as required. 384 Supplying and drawingof cable Fire Retardant PVC insulated copperconductorcableintheexistingsurface/recessed steelconduitoffollowingpairs,coresandsizeincluding connections and interconnections etc. as required. (A)Speaker cable Single pair, 2-core, 1.5 sqmm 385 Sec.2.0 Audio Visual SystemOT Rooms ( 11 Nos.)Supply, Installation, Testing and Commissioning of 600 mm beamforming microphone array Ceiling tile, Support beamforming from 100Hz to 20kHz, support AEC, Noise Cancellation, Gain & Level control, Mute on/off, Support Dante protocol, Coverage up to 24 feet redius, with required PoE / Non POE Power supply & mouting accessories from the ceiling as per site requirement, as per technical specification etc. as required. 386 Supply, Installation, Testing and Commissioning of DSP Mixer with 4 mic/line inputs (AEC), 8 mic/line outputs, built-in USB audio,VoIP conferencing interface , analog telephone interface, Dante protocol support, support SIP Based configuration,as per technical specification etc. as required. 387 Supply Installation Testing & Commissioning of multiviewer with seamless matrix switcher that can also be used as a 2x2 video wall driver or dual and quad multi-viewers. The unit allows switching between inputs with a clean video cut (frame-to-frame switching with no glitches).Input 4 HDMI connectors (HDMI, HDCP version 1.1), Output 4 HDMI connectors (HDMI, HDCP version 1.1), Resolution NATIVE, 480p, 576p, 720p50, 720p60, 1080p24, 1080p50, 1080p60, 1024x768, 1280x800, 1280x1024, 1366x768, 1440x900, 1600x900, 1600x1200, 1680x1050 or 1920x1200,VIDEO LATENCY Progressive input: 30ms (typical), Selectable Operation Modes — Matrix switcher, video wall, dual display (PIP/P&P) and quad display.Multiple Output Aspect Ratios. as required.as per technical specification etc. as required. 388 Supply Installation Testing & Commissioning of 4K Matrix Switcher with 8 Input and 8 output. Input-8 HDMI connectors, 8 unbalanced stereo audio on 3.5mm mini jacks, Output-8 HDMI connectors, 8 balanced audio stereo output on a 5–pin terminal blocks (+4dBu nominal), Ports- 1 USB, 1 RS–232, 1 Ethernet, 1 USB for powering an external device, Compliance with HDMI Standard- Supports HDMI and HDCP 1.4, Resolution- Up to 4K@60Hz (4:2:0) and 4K@30Hz (4:4:4), Ethernet Remote connection, as per technical specification etc. as required. 389 Supply, Installation, Testing & Commissioning of 4.5-inch 2-way Ceiling-mount loudspeaker.Frequency Range-65 Hz to 18 kHz, Rated noise power/Voltage -30 watts / 22 volts (rms), Sensitivity-87.5 dB SPL,Coverage- 150° conical, Maximum continuous SPL-102 dB, Maximum peak SPL- 108 dB, LF Transducer - 4.5-inch weather resistant paper cone woofer,HF Transducer-0.75-inch aluminum dome tweeter, Nominal impedance- 16O, Transformer Taps- 70 V: 30 W, 15 W, 7.5 W, 3.75 W; 100V: 30W, 15 W, 7.5 W. Mounting Hardware Included as per technical specification etc. as required. 390 Supply, Installation, Testing & Commissioning of 2 Channel Class D amplifier. Power 120W per channel @8?/4?/70V/100V. Frequency Response at 8 O - 20 Hz – 20 kHz +/- 0.5 dBz, Signal to Noise ratio -> 100 dB, Input impedance - >10k, balanced or unbalanced, low impedance 4 ? or 8 ?,high impedance direct drive 70 V or 100 V modes ,Selectable 80 Hz highpass filter on each channel, Size - 1RU as per technical specification etc. as required. 391 Supply Installation Testing & Commissioning of 4K Encoder & Decorder, User configured as encoder or decoder, treaming Support — Multicast, Unicast, RTP over RTSP Powered by the network (PoE) . Input-1 HDMI: On a female HDMI connector , Output-1 HDMI: On a female HDMI connector 1 IR: On a 3.5mm mini jack, Port-1 10GbE Ethernet: On an R–J45 connector, 1 Unbalanced Stereo Audio: On a 3.5mm mini jack, 1 1GbE Ethernet: On an R–J45 connector, 1 RS-232: On a 3–pin terminal block connector, HDCP 2.2 &1.4, DVI 1.0, as per technical specification etc. as required. 392 Supply Installation Testing & Commissioning of Single HDMI Module Passive Wall Plate — HDMI: Front Panel Connection — 1 HDMI (F). Rear Panel Connection — 1 HDMI (F) on a flat, flexible cable, with required mouting back box as per site requirement, as per technical specification etc. as required. 393 Supply Installation Testing & Commissioning of Dual HDMI Module Passive Wall Plate — HDMI: Front Panel Connection — 1 HDMI (F). Rear Panel Connection — 1 HDMI (F) on a flat, flexible cable, with required mouting back box as per site requirement, as per technical specification etc. as required. 394 Supply, Installation, Testing and Commissioning of Wireless Digital Presenter Lavalier microphone with belt pack transmitter and single receiver with rechargable batteries and rack mount kit and table top charger also must be included in the proposal and transmission RF output >= 100 mW. as per technical specification etc. as required. 395 Supply, Laying, Testing and Commissioning of Ultra Flexible High Speed HDMI Cables HDMI Cable 10 Meter HDMI 2.0 Cable Male to Male, support Deep Color, 4K 4096 x 2160 @60Hz; 3840 x 2160 @ 60Hz 4:4:0, Minimum conductor gauge - 30AWG, gold Plating, as per technical specification etc. as required. 396 Supply, Laying, Testing and Commissioning of Ultra Flexible High Speed HDMI Cables HDMI Cable 15 Meter HDMI 2.0 Cable Male to Male, support Deep Color, 4K 4096 x 2160 @60Hz; 3840 x 2160 @ 60Hz 4:4:0, Minimum conductor gauge - 30AWG, gold Plating, as per technical specification etc. as required. 397 Supply, Laying, Testing and Commissioning of Ultra Flexible High Speed HDMI Cables HDMI Cable 20 Meter HDMI 2.0 Cable Male to Male, support Deep Color, 4K 4096 x 2160 @60Hz; 3840 x 2160 @ 60Hz 4:4:0, Minimum conductor gauge - 30AWG, gold Plating, as per technical specification etc. as required. 398 Supply, Laying of Shielded Twisted Pair (STP) 4 Pairs 23 AWG Cable with connector, as per technical specification etc. as required. 399 Supply, Laying, Testing and Commissioning of Two 16 AWG conductors non- plenum Speaker Cable, for High performance cable for audio signals as per technical specification etc. as required. 400 Supplying, installation, testing and commissioning of Networking enclosure - Floor mounted, 19 mounting frame, usable height 24U, 600mmW x 600mmD etc. as per technical specification etc. as required. 401 Audio Visual System @ Lecture Hall & Conference Room( 02 Nos.)Supplying, installation, testing and commissioning of 5000 lumens WUXGA 3LCD Laser Projector, Contrast Ratio - 2,500,000 : 1, With Standard Lens, Input terminal : D-Sub 15Pin X 2nos. HDbaseT RJ45 x 1, HDMI X 2nos, Stereo Mini Jack x 2nos. Output Terminal : D-Sub 15Pin: 1 Shared with Computer 2, Stereo Mini Jack: 1 with ceiling mount kit (2feet + 2feet) or as per site requirement. 402 Supplying, installation, testing and commissioning of 165(81 X 144) inch Diagonal or equivalent size 16:10 aspect ration motorized projector screen.as per technical specification etc. as required. 403 SITC of 86 Smart Interactive 4K display |7H hardness toughen anti glared glass | In-built Android 8.0, RAM 3 GB, 16 GB ROM, 32 GBMemory Card |10 Points Touch in Android and 20 points Touch in Windows | Smart Object recognition and responsive multi-touch | Multiple Inputs for connectivity | 15W x 2 Speakers | Inbuilt Screen Sharing Software | Slimmer Frame|Customize GUI| Wireless presentation with Quad View Option| Broadcast upto 200 Devices | Remote Display Management 404 Supplying, installation, testing and commissioning of Cable cubby Includes a Universal power outlet X 2 Nos. and space for four customer-supplied cables HDMI Port X 1nos, RJ-45 X 2 Nos,as per technical specification etc. as required. 405 Supplying, installation, testing and commissioning of 8x4 matrix 4K video scalers cum switcher with minimum 8 X HDMI IN, 4 X HDMI Out, HDCP 2.2, EDID supported as per technical specification etc. as required. 406 Supply installation testing and commissioning of4K HDBT Receiver / Scaler Tool with Input: HDBaseT RJ45 x 1nos, Outputs: HDMI x1nos and Balanced Analog Stereo Audio x 1nos, as per technical specification etc. as required. 407 Supply installation testing and commissioning of4K HDBT Transmitter / Scaler Tool with Output: HDBaseT RJ45 x 1nos, Inputs: HDMI x1nos and Balanced Analog Stereo Audio x 1nos, as per technical specification etc. as required. 408 Supply, Installation, Testing and Commissioning of DSP Mixer with 12 mic/line inputs (AEC), 8 mic/line outputs, built-in USB audio,VoIP conferencing interface , analog telephone interface, Dante protocol support, support SIP Based configuration,as per technical specification etc. as required. 409 Supply, Installation, Testing & Commissioning of 6.5-inch two-way Surface-mount loudspeaker. HF transducer-1 silk dome tweeter / 1 voice coil, horn loaded, LF transducer - 6.5 weather treated paper cone woofer, 1.5 / 38 mm voice coil, Frequency range - 58 Hz - 20k Hz, Rated noise power / voltage - 150 W / 49 V (rms), Sensitivity-89 dB SPL, Coverage- 105° conical, Maximum continuous SPL-110 dB, Maximum peak SPL- 116 dB,Ingress protection-IP-54, Rated impedance- 16O. Mounting Hardware included with Sealed input panel cover and powder coated aluminum grilles for added weather resistance. as per technical specification etc. as required. 410 Supply, Installation, Testing & Commissioning of 8 Channel Class D amplifier. Power 200W per channel @8?/4?/70V/100V. Frequency Response at 8 O - 20 Hz – 20 kHz +/- 0.5 dBz, Signal to Noise ratio -> 103 dB, Input impedance - >10k, balanced or unbalanced, low impedance 4 ? or 8 ?,high impedance direct drive 70 V or 100 V modes ,Selectable 80 Hz highpass filter on each channel, Size - 1RU as per technical specification etc. as required. 411 Supply, Installation, Testing and Commissioning of Wireless Digital Vocal Handheld microphone with transmitter and single receiver with rechargable batteries and rack mount kit and table top charger also must be included in the proposal and transmission RF output >= 100 mW. as per technical specification etc. as required. 412 FFTG WORKSFIRE PUMPS & ACCESSORIES, HYDRANTS, HOSE REEL, SPRINKLER SYSTEM, FIRE EXTINGUISHERS & SIGNAGESSupply, Installation, Testing and Commissioning of Electric driven Terrace pump suitable for automatic operation and consisting of following: complete in all respect as required.a) Horizontal, centrifugal, end suction pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal and flow of 450 lpm at 40m.head conforming to IS standards. b) Squirrel cage induction motor with suitable HP with synchronous speed 3000 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards.c) Common Base plat for Pump and motor and coupling, coupling guard, vibration pad, cables and other accessories as required for complete installation of pump set. 413 Supplying, Installation, Testing and Commissioning of Control Panel suitable for automatic operation of fire fighting pump consisting (Terrace pump - for 450 lpm)(a) Necessary cabling, wiring, earthing from panel to individual equipment shall be included in the quoted price.(b) Facility for more selections i.e auto or manual.(c) Protection failure and control cabling.(d) interlocking of pressure switch with pumpsMajor component of panel are as under :MCB with soft starterSingle phasing preventorWith push buttonOn,off, trip indication lampSpace heater with thermostateCooling exhaust fan 414 Supply, Installation, Testing and Commissioning of 150 mm dia Pressure Gauge of range 0 - 15 Kg / cm² conforming to IS - 3624 having bourdon tube of stainless steel 316 in cast aluminium, stove enameled, black, weather proof case with outer, screwed aluminium bezel and complete with necessary U-type stainless steel siphon tube and cock including providing suitably painted angle iron support to the tube etc.as per specification complete as required. 415 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. 416 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia. 417 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia. 418 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia. 419 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :65 mm dia. 420 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50 mm dia. 421 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :40 mm dia. 422 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia. 423 Supply, installation, testing and commissioning of Y Strainer of CI Body flanged ends with stainless steel strainer 304 having 1.2mm perforation complete with necessary accessories:100 mm dia. 424 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia. 425 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :80 mm dia. 426 Supply, Installation, Testing and Commissioning of Cast iron Dual plate Check valve with all require accessories (PN 1.6)(a)100 mm dia. 427 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gun Metal 428 Supply, Installation, Testing and Commissioning of Fire Hose Cabinet of size 750mmx600mx250mm fabricated from 16 swg thick MS sheet with 6mm thick glazed hinged type centre opening doors having locking arrangement suitable for accommodating 2 nos RRL hose pipes, 1 no. nozzle, branch pipe & painting with two coats of anti-corrosive primer and two coats of approved red enamel paint etc. complete as required. 429 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal 430 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun Metal 431 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.1)20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 125852)20 mm nominal internal dia gun metal globe valve & nozzle.3)Drum and brackets for fixing the equipmets on wall.4)Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 432 Providing and fixing standard fireman Axe with heavy dutyinsulated rubber handle as per IS: 926 with clamps. 433 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 434 Supply, Installation, Testing and Commissioning of Gun Metal Air Release Valve with necessary fittings. Size: 25 mm (For Riser) 435 Supply, installation, testing and commissioning of Pump on/off Remote switches to each internal hydrant valve with required accessories. 436 Supply, installation, testing and commissioning of XLPE insulated FRLS copper armoured Cable from each Pump on/off switches to Panel with all necessary accessories. Size: 4 core x 2.5 sq. mm 437 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler 438 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Upright Sprinkler 439 Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steelcomplete with 15 NPT on reducer thread withmaximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPTfemale thread with reducer, nipple, 2 side brackets,center bracket, stockbar of following sizes complete as required.700mm 440 Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steelcomplete with 15 NPT on reducer thread withmaximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPTfemale thread with reducer, nipple, 2 side brackets,center bracket, stockbar of following sizes complete as required.1000mm 441 Supply, installation, testing and commissioning ofCarbon Dioxide (Co2) type Fire Extinguisher of 4.5 kg confirm to IS:15683, stored pressure, wheel type with ISI marked with required accessories including wall suspension brackets. 442 Supply, installation, testing and commissioning of ABC (MAP 90%)type6 kg stored pressure, squeeze type confirm to IS:15683, with ISI marked with required accessories including wall suspension brackets. 443 Providing, fixing AUTO GLOW photo luminescent Signages as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes:Fire Equipment: 4 x 12 444 M.S. Under Ground PipeProviding, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and laying underground including one coat of anticorrosive primer and wrapping material of 4mm thick & 150 mm width protection coating as per IS:10221 by thermo fusion process,overlap shall be maintained at 15mm as per specifications complete as required:100 mm dia. 445 M.S. Under Ground PipeProviding, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and laying underground including one coat of anticorrosive primer and wrapping material of 4mm thick & 150 mm width protection coating as per IS:10221 by thermo fusion process,overlap shall be maintained at 15mm as per specifications complete as required:80 mm dia. 446 Getting Approval/NOC of Fire protection system (Hydrant, Sprinkler etc..) from local fire authority and any other relevant statutory authority at initial and various other stages of work, including preparation of report/drawings as per fire authority. 447 01-HVAC WORKSSec.1.0 Machinery Works Air Cooled DX type condensing units for Air Handling UnitsAir Cooled type Condesing Unit with the following componentsSupply, Installation, testing & commissioning of MICROPROSSER BASED air cooled Ductable split Air Conditioning units as specified; each unit shall comprise of separate indoor and outdoor unit as under :The outdoor (condensing unit) shall be of Corrosion resistant Galvanized powder coated or equivalent steel Sheet low vibration assembly installed with suitable vibration isolators and comprising of energy efficient Scroll compressor with controls such as Thermal Protector, HP / LP cutouts, Pressure Relief Valve; the outdoor unit shall also comprise of finned tube air cooled condenser and condenser fan unit; the units shall have integral refrigerant copper piping within compressor and condenser and accessories such as Refrigerant shut off valves atcompressors and liquid Refrigerant outlet if required at filter dryer; Cooling fans shall have protective metal frame. Factory supplied Conrol & Operating Panel with required MCB, protections housed in weather proof MS painted enclosure, located near the AHU with required outgoing cabling from panel to ODU and AHU; the panel shall be provided with incomer power cable with isolator by electrical agency. AHU & respective ODUs shall be interlocked with each other. ODU shall not be started alone, with out starting of AHU.Electrical Panel will be complete with necessary starters, fuses, switches, timrers, over-load relays, contactors, push button and indicating lamps, single phasing PREVENTOR etc and also with Corded Remote Controller.The panel should have 1 No. Potential freee contactor to connect with central fire detection system. The panel should also have voltage scanner to ensure stabilized power input to the machine.All Outdoor units shall be mounted on MS angle base frame structure duly black painted with synthetic epoxy paint.The frame structure shall be mounted on MS plate & serrated rubbed pads.4.00 TR Condesing unit ( Minor OT 6th Fl) 448 Air Cooled DX type condensing units for Air Handling UnitsAir Cooled type Condesing Unit with the following componentsSupply, Installation, testing & commissioning of MICROPROSSER BASED air cooled Ductable split Air Conditioning units as specified; each unit shall comprise of separate indoor and outdoor unit as under :The outdoor (condensing unit) shall be of Corrosion resistant Galvanized powder coated or equivalent steel Sheet low vibration assembly installed with suitable vibration isolators and comprising of energy efficient Scroll compressor with controls such as Thermal Protector, HP / LP cutouts, Pressure Relief Valve; the outdoor unit shall also comprise of finned tube air cooled condenser and condenser fan unit; the units shall have integral refrigerant copper piping within compressor and condenser and accessories such as Refrigerant shut off valves atcompressors and liquid Refrigerant outlet if required at filter dryer; Cooling fans shall have protective metal frame. Factory supplied Conrol & Operating Panel with required MCB, protections housed in weather proof MS painted enclosure, located near the AHU with required outgoing cabling from panel to ODU and AHU; the panel shall be provided with incomer power cable with isolator by electrical agency. AHU & respective ODUs shall be interlocked with each other. ODU shall not be started alone, with out starting of AHU.Electrical Panel will be complete with necessary starters, fuses, switches, timrers, over-load relays, contactors, push button and indicating lamps, single phasing PREVENTOR etc and also with Corded Remote Controller.The panel should have 1 No. Potential freee contactor to connect with central fire detection system. The panel should also have voltage scanner to ensure stabilized power input to the machine.All Outdoor units shall be mounted on MS angle base frame structure duly black painted with synthetic epoxy paint.The frame structure shall be mounted on MS plate & serrated rubbed pads.5.50 TR Condesing unit ( 2 nos.for OT -1 ,2,35th Fl + 2 nos.for OT -1 ,2,3 6th Fl+ 1 nos.for Septic OT 6th Fl ) 449 Air Cooled DX type condensing units for Air Handling UnitsAir Cooled type Condesing Unit with the following componentsSupply, Installation, testing & commissioning of MICROPROSSER BASED air cooled Ductable split Air Conditioning units as specified; each unit shall comprise of separate indoor and outdoor unit as under :The outdoor (condensing unit) shall be of Corrosion resistant Galvanized powder coated or equivalent steel Sheet low vibration assembly installed with suitable vibration isolators and comprising of energy efficient Scroll compressor with controls such as Thermal Protector, HP / LP cutouts, Pressure Relief Valve; the outdoor unit shall also comprise of finned tube air cooled condenser and condenser fan unit; the units shall have integral refrigerant copper piping within compressor and condenser and accessories such as Refrigerant shut off valves atcompressors and liquid Refrigerant outlet if required at filter dryer; Cooling fans shall have protective metal frame. Factory supplied Conrol & Operating Panel with required MCB, protections housed in weather proof MS painted enclosure, located near the AHU with required outgoing cabling from panel to ODU and AHU; the panel shall be provided with incomer power cable with isolator by electrical agency. AHU & respective ODUs shall be interlocked with each other. ODU shall not be started alone, with out starting of AHU.Electrical Panel will be complete with necessary starters, fuses, switches, timrers, over-load relays, contactors, push button and indicating lamps, single phasing PREVENTOR etc and also with Corded Remote Controller.The panel should have 1 No. Potential freee contactor to connect with central fire detection system. The panel should also have voltage scanner to ensure stabilized power input to the machine.All Outdoor units shall be mounted on MS angle base frame structure duly black painted with synthetic epoxy paint.The frame structure shall be mounted on MS plate & serrated rubbed pads.8.50 TR Condesing unit ( 1 nos.for OT -45th Fl + 1 nos.for OT -4 6th Fl+ 1 nos.for OT 6th Fl + 2 for Septic OT 6th Fl) 450 OZONE INJECTION SYSTEM FOR PREMIUM OPERATION THEATERS Ozone generator -25 gram/hr, Supply installation with all required accessories, fixtures and supporting material, testing and commissioning of Ozone generator as specified capable of producing upto 25 grams/hour at a concentration of not less than 7% with external Oxygen as feed gas for each AHU system. Air based systems will not be accepted. The Ozone shall be produced by Corona discharge method only. The Ozone generator shall not be mounted but placed outside duct for easy access and maintenance. The Ozone generator shall be air cooled and controllable from 0-100% dosage. The Ozone dielectric shall be tubular and made of ceramic and/or SS 316. All Ozone contacts shall be made of Teflon material only.Ozone generator shall be placed inside a panel and insulated with acrylic for protection as per manufacturer recommended procedure and guidlines 451 Supply installation with all required accessories, fixtures and supporting material, testing and commissioning of Oxygen concentrator - 0-8 lpm adjustable output, with greater than 90% purity. Low noise with prefilter and bacterial filters installed 452 Supply installation with all required accessories, fixtures and supporting material, testing and commissioning of Ambient Ozone analyser with Remote-Mount Sensor User selectable control relays to automatically control Ozone system Indicator lights display ozone is above 0.1 ppm Range: 0 - 5 ppm. Display: LCD. 453 Sec.2.0 Air Moving Equipment Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of100 % Fresh Air type Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with VFD driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter and Fine filter with 5 micron, Dual Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils & DX coil (standby Unit), SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses.Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat withwater proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB<=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.2752 CFM / 20.42 TR With 3.0 kW Strip Heaters & Humidistate For Septic O.T, Septic Labour & Recovery Room at Sixth Floor (8.5 TR X 2 Nos.+ 5.5 TR X 1 Nos. stand by Condensing Units) 454 Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coatedinner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with VFD driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Dual Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils & DX coil (standby Unit), SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection,Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat withwater proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB<=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration)1900 CFM / 3.36 TR For Minor O.T at Sixth Floor (4.0TR X 1 Nos. stand by Condensing Units) 455 Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coatedinner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with VFD driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Dual Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils & DX coil (standby Unit), SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection,Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat withwater proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB<=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration)3735 CFM / 7.45 TR With 4.0 kW Strip Heaters & Humidistate For O.T at Sixth Floor(8.5 TR X 1 Nos. stand by Condensing Units) 456 Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coatedinner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with VFD driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection,Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat withwater proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB<=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration)7750 CFM / 14.65 TR With 11.0 kW Strip Heaters & Humidistate For Clean Area of CSSD at Basement lvl 457 Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended ChilledWater Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters 70% down to 20 micron, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre-assembled valve station with set of brass ball valve with Y strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent control cum balancing valve of minimum PN25 ratingwith P/T plugs and minimum IP54 electrothermic / motoric modular actuator (0 to 10 Volt DC Signal) fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required.The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturers factory.750 CFM 458 Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended ChilledWater Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters 70% down to 20 micron, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre-assembled valve station with set of brass ball valve with Y strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent control cum balancing valve of minimum PN25 ratingwith P/T plugs and minimum IP54 electrothermic / motoric modular actuator (0 to 10 Volt DC Signal) fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required.The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturers factory.950 CFM 459 Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl and With 10 Micron Filteration; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.2752 CFM / 40mm Static Pressure For Septic O.T, Septic Labour & Recovery Room at Sixth Floor 460 Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.3900 CFM / 40mm Static Pressure For Dirty & Washing Cleaning Area of CSSD at Basement lvl 461 Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.2000 CFM / 40mm Static Pressure For Storage Area at Ground Floor 462 Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.4500 CFM / 40mm Static Pressure For Kitchen Area at Ground Floor 463 Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.7900 CFM / 40mm Static Pressure For Dirty Area at First Floor 464 Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.5800 CFM / 40mm Static Pressure For Dispatch & Linen Area & Drying Area at First Floor 465 Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Fresh Air Unit; unit shall have leakproof canvass connection at descharge side along with damper & filter at suction side along with plenum; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.3150 CFM / 40mm Static Pressure For Autoclave Area & Change Rooms at Basement lvl 466 Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Fresh Air Unit; unit shall have leakproof canvass connection at descharge side along with damper & filter at suction side along with plenum; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.1600 CFM / 40mm Static Pressure For Storage Area at Ground Floor 467 Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Fresh Air Unit; unit shall have leakproof canvass connection at descharge side along with damper & filter at suction side along with plenum; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.6300 CFM / 40mm Static Pressure For Dirty Area at First Floor 468 Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Fresh Air Unit; unit shall have leakproof canvass connection at descharge side along with damper & filter at suction side along with plenum; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.4650 CFM / 40mm Static Pressure For Dispatch & Linen Area & Drying Area at First Floor 469 Supply installation testing and commissioning of Air Washer.GI Powder coated double skinned sandwitch insulated Sectionalized Fresh Air Units; shall have Fan Section having backward curved centrifugal fan+ suitable Pole TEFC motor + drive package, Washer section with Cell deck / equivalent air wash long life cooling pad media including manufacturer supplied water distribution pad system with 2 pass PVC eliminators, manifold, Fraction HP Pumps with motor, recirculation GI / PVC piping with valves, fittings / MS corrossion proof painted Storage Sump with overflow, makeup, drain & quickfill with Ball & Float Valve assembly / Intake Filter section of 20 micron with Intake Louvers, supply side GI Dampers & canvass connections, complete with starter panel for blower fan & pump including associated outgoing cabling; Unit shall have 90% air wash efficiency & 400 FPM face velocity with 10 mm WC drop across cooling media; motor shall be selected for following fan ratings w.r.t minimum 60% volumetric efficiency; units to be mounted on vibration isolation serrated rubber pads and completely leak proof construction.Supply installation testing and commissioning of wall mounted IP 55 protection electrical starter panel for Humidifier Fan motor / Pump motors as composite unit including overload and short circuit protection, auto-manual provision, duly internally wired and tested; price shall include 10 rmt power cable of suitable size/rating from Panel upto Fan motor and Pump motors3600 CFM/ 50mm Static Pressure for Kitchen Area at Ground Floor 470 Supply, installation, testing and commissioning of Tube Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors with VFD & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly.Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. All other fan Floor mounting accesories will be provide with the fan. Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection,Motor Status On / Off / Trip, command, Automanual Status, fire status controlling, contacts for remote operation through Operating Panels, BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested.7000 CFM/ 20mm Static Pressure for Medical Gas 471 Sec.3.0 Chilled Water Piping INSULATED CHILLED WATER PIPING (Nitrile rubber insulation)Supplying,laying/fixing,testingandcommissioningoffollowing nominalsizesofchilledwaterpipinginsidethebuilding(with necessaryclamps,vibrationisolatorsandfittingsbutexcluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber ofminimum 45 Kg / cu m density, thermalconductivity 0.037W/MKorbetterat20degmean temperatureclassOinsulationappliedbysuitableadhesive completeincludingrepairingofdamagetobuildingetc.asper specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. C class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.65 mm dia.(32 mm thick insulation) 472 INSULATED CHILLED WATER PIPING (Nitrile rubber insulation)Supplying,laying/fixing,testingandcommissioningoffollowing nominalsizesofchilledwaterpipinginsidethebuilding(with necessaryclamps,vibrationisolatorsandfittingsbutexcluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber ofminimum 45 Kg / cu m density, thermalconductivity 0.037W/MKorbetterat20degmean temperatureclassOinsulationappliedbysuitableadhesive completeincludingrepairingofdamagetobuildingetc.asper specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. C class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.50 mm dia.(32 mm thick insulation) 473 INSULATED CHILLED WATER PIPING (Nitrile rubber insulation)Supplying,laying/fixing,testingandcommissioningoffollowing nominalsizesofchilledwaterpipinginsidethebuilding(with necessaryclamps,vibrationisolatorsandfittingsbutexcluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber ofminimum 45 Kg / cu m density, thermalconductivity 0.037W/MKorbetterat20degmean temperatureclassOinsulationappliedbysuitableadhesive completeincludingrepairingofdamagetobuildingetc.asper specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. C class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.40 mm dia.(32 mm thick insulation) 474 INSULATED CHILLED WATER PIPING (Nitrile rubber insulation)Supplying,laying/fixing,testingandcommissioningoffollowing nominalsizesofchilledwaterpipinginsidethebuilding(with necessaryclamps,vibrationisolatorsandfittingsbutexcluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber ofminimum 45 Kg / cu m density, thermalconductivity 0.037W/MKorbetterat20degmean temperatureclassOinsulationappliedbysuitableadhesive completeincludingrepairingofdamagetobuildingetc.asper specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. C class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.32 mm dia.(32 mm thick insulation) 475 INSULATED CHILLED WATER PIPING (Nitrile rubber insulation)Supplying,laying/fixing,testingandcommissioningoffollowing nominalsizesofchilledwaterpipinginsidethebuilding(with necessaryclamps,vibrationisolatorsandfittingsbutexcluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber ofminimum 45 Kg / cu m density, thermalconductivity 0.037W/MKorbetterat20degmean temperatureclassOinsulationappliedbysuitableadhesive completeincludingrepairingofdamagetobuildingetc.asper specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. C class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.25 mm dia.(32 mm thick insulation) 476 INSULATED CHILLED WATER PIPING (Nitrile rubber insulation)Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation applied by suitable adhesive, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.19 mm dia.(19 mm thick insulation) 477 INSULATED VALVESSupplying,fixing,testingandcommissioningof followingvalves, strainers,gauges in the chilledwater plumbingduly insulatedto the samespecificationsas the connectedpipingand adequately supported as per specifications.providing and erecting BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- RingPN 16 pressure rating for chilled water/hot water circulation as specified65mm dia. 478 providing and erecting BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- RingPN 16 pressure rating for chilled water/hot water circulation as specified50mm dia. 479 providing and erecting BALANCINGVALVE WITH BUILT IN MEASURINGFACILITYwith C I body flanged constructionwith EPDM coated disc with long pitch withprotectedoutpipeinsulation&PN16pressureratingfor chilled / hot water circulation as specified.50mm dia. 480 providing and erecting BALANCINGVALVE WITH BUILT IN MEASURINGFACILITYwith C I body flanged constructionwith EPDM coated disc with long pitch withprotectedoutpipeinsulation&PN16pressureratingfor chilled / hot water circulation as specified.40mm dia. 481 providing and erecting Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.65mm dia. 482 providing and erecting Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.50mm dia. 483 providing and erecting Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.40mm dia. 484 providing and erecting Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.32mm dia. 485 Providingandfixinginpositiontheindustrialtypepressure gauges with gun metal / brass valves complete as required 486 Providing & fixing in position the mercury in glass industrial type thermometers. 487 SS BALL VALVE complete with Flanges Nutbolts with SS Body and Working parts.40mm dia. 488 SS BALL VALVE complete with Flanges Nutbolts with SS Body and Working parts.32mm dia. 489 SS BALL VALVE complete with Flanges Nutbolts with SS Body and Working parts.25mm dia. 490 Supplying, fixing, testing and commissioning of Automatic Air Purge Valve at AHU chilled water outlet pipe duly insulated to the same specifications as the connected piping and adequately supported as per specifications.20mm dia. 491 Sec.4.0 Condenser Water Piping Supply, Installation,Testing and Commissioningof followingsizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of acceptingupto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.65mm dia. 492 Supply, Installation,Testing and Commissioningof followingsizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of acceptingupto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.50mm dia. 493 Supply, Installation,Testing and Commissioningof followingsizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of acceptingupto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.40mm dia. 494 Supply, Installation,Testing and Commissioningof followingsizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of acceptingupto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.32mm dia. 495 Sec.5.0 Ducting, Grills, Diffuser and Insulation DUCTING, GRILLS, DIFFUSER AND INSULATIONSupply,installation,balancingandcommissioning offactory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet 496 DUCTING, GRILLS, DIFFUSER AND INSULATIONSupply,installation,balancingandcommissioning offactory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.80 mm sheet 497 DUCTING, GRILLS, DIFFUSER AND INSULATIONSupply,installation,balancingandcommissioning offactory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 1.00 mm sheet 498 DUCTING, GRILLS, DIFFUSER AND INSULATIONSupply,installation,balancingandcommissioning offactory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 1.25 mm sheet 499 Supply, installation,balancing and commissioning of fabricated at siteGSSsheetmetalrectangular/round ductingcomplete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet 500 Supply, installation,balancing and commissioning of fabricated at siteGSSsheetmetalrectangular/round ductingcomplete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.80 mm sheet 501 Supply, installation,balancing and commissioning of fabricated at siteGSSsheetmetalrectangular/round ductingcomplete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 1.00 mm sheet 502 Supply, installation,balancing and commissioning of fabricated at siteGSSsheetmetalrectangular/round ductingcomplete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 1.25 mm sheet 503 Supply,installation,testingandcommissioningofGIvolume controlduct dampercompletewith neoprenerubbergaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. 504 Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers complete as per specifications and size & shape as per site requirement and approved design. 505 Supplying & fixing of powder coated extruded aluminium Return Air Grillswith louvers but without volume control dampers complete as per specifications and size & shape as per site requirement and approved design. 506 Supplying, fixing testing commissioning of supply air diffuser of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core and size & shape as per site requirement and approved design. 507 Supplying, fixing testing commissioning of Return air diffuser of powdercoatedaluminiumwithoutvolumecontroldampers with anti smudge ring & removable core and size & shape as per site requirement and approved design. 508 Supply, installation,testing & commissioningof thermal insulatedflexibleductoffollowingsizesdulysupported at regular interval asper site requirement etc. complete as required as per specifications.(A) 200 mm dia. 509 Supplying,Fixing, testingand commissioningof fire dampersin supply air duct/mainbranch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorizedand spring return so as to close the damperin the event of power failure automatically and open the same in case ofpowerbeingrestored.Thespringreturnactionshallbe inbuiltmechanismandnotexternallymounted.Thedamper shallalsobeclosedintheeventoffiresignalcompleteas required and as per specifications.Fire Damper 510 Supplying,Fixing, testingand commissioningof fire dampersin supply air duct/mainbranch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorizedand spring return so as to close the damperin the event of power failure automatically and open the same in case ofpowerbeingrestored.Thespringreturnactionshallbe inbuiltmechanismandnotexternallymounted.Thedamper shallalsobeclosedintheeventoffiresignalcompleteas required and as per specifications.Actuator 511 Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. 512 Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with50mmthick,density32kg/cu.mresinbondedglassfiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with0.80 mmperforated aluminium sheet etc.complete as required and as per specifications. 513 Supplyingand fixing of followingthickness duly laminated aluminumfoil of mat finish closed cell Nitrile rubber (Class O) insulationonexistingductafterapplyingsuitable adhesivefor Nitrilerubber.The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.19mm 514 Supplyingand fixing of followingthickness duly laminated aluminumfoil of mat finish closed cell Nitrile rubber (Class O) insulationonexistingductafterapplyingsuitable adhesivefor Nitrilerubber.The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.25mm 515 Supplyingandfixing50mmthickaluminiumfoilfacedresin bonded fibre glass insulation (on duct) of density 24 kg/cu.m or mineral wool insulation(non combustible) of density 44 kg/cumafter applying two coats of cold setting adhesive (CPRX compound) sealing all joints with self adhesive aluminium tape & covering with 0.63mmx19mmGI wire mesh netting & butting all joints and laced with GI wire completeand finallycovered withonelayeroftarfeltstuckwithhotbitumen asper specifications and as required. (for outdoor applications) 516 Sec.6.0 Miscelleneous WorksRigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.19 mm Dia. 517 Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.25 mm Dia. 518 Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.32 mm Dia. 519 Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.40 mm Dia. 520 Providing and erecting Inverter based approved make split air-conditioning unit consisting of condensing unit with variable speed fan motor, inverter type hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means ofextra supplied proper insulated copper tubing,drain PVC pipes suitable for ( cost includes Eco Friendly green gas charging and 15A plug top & Remote Control & MS Stand) with necessary core cutting.(B) for 1.5ton capacity 521 Providing and erecting Inverter based approved make split air-conditioning unit consisting of condensing unit with variable speed fan motor, inverter type hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means ofextra supplied proper insulated copper tubing,drain PVC pipes suitable for ( cost includes Eco Friendly green gas charging and 15A plug top & Remote Control & MS Stand) with necessary core cutting.(C) for 1.7 to 2ton capacity 522 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation 523 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation 524 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation 525 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation 526 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation 527 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation 528 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation 529 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation 530 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation 531 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation 532 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation 533 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-09-2022 Reply to Quires Financial Bid 09-09-2022

Key Value

Document Fees
INR 5000 /-
EMD
INR 5640000.0 /-
Tender Value
INR 46.33 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail