Supply Of Spare Parts For Regular Upkeep Of Laboratory Equipments And Installation Of New Instruments Required For Different Water Testing Laboratories Related To Water Quality Monitoring And Survelliance Activities Under Public Health Engineering Department, Government Of West Bengalmonitoring And Surveillance Activities Under Public Health Engineering Dep- 1 Tungsten Lamp 2 Lc Display For Uv Visible Spectrophotomete 3 Power Regulator Supply Package For Uv1 Double Beam Spectrophotometer ( Thermo ) 4 Chasis With Motherboard, Integrated Key Pad, Processor Board, Display, Cell Holder For Uv-Vis Spectrophotometer 5 Electrode For Cyberscan Ph 510 / 700 Ph Meter, General Purpose Epoxy Body Ph Electrode 6 Mother Board With Integrated Key Pad & Display For Ph 510 / 700 7 Power Pack For Cyberscan Ph 510 / 700 Ph Meter 8 Basic Ion Meter Ph Ion 7320 / Star A 214 / Accumet Ion Meter 9 Fluoride Ion Selective Electrode Ionplus-Accumet Combonation Solid State Combination For Fluoride Ion Meter 10 Temperature Probe For Ion Meter 11 Time Alarm Including Relay Contactor For Autoclave 12 Kettle Type Heating Element, 3 Kw For Autoclave 13 Uv-Lamp For Laminar Flow Bench 14 Electronic Choke For Uv-Lamp Of Laminar Flow Chamber 15 Digital Temperature Indicator Cum Controller For Incubators 16 Stirring Fan For Incubator 17 Supply Of Temperature Sensor For Incubator With Compensating Cable 18 Dropping Funnel For Glass Distillation Assembly 19 Mantle Structure 5 Lit With Cloth-Element-Energy Regulator For All Glass Water Distillation Assembly 20 5-Lit Glass Reservoir For Water Distillation Plant-All Glass-Coiled Type 21 Tripple Jacketted Condenser For Water Distillation Plant-All Glass 22 Kettle Heating , 2 Kw For Water Distillation Plant Ss 23 Heating Plate With Integrated Coil For Hot Plate 24 Kettle Heating Element For Water Bath 1Kw 25 Silicon Tube Fitting For Distt Water Unit, Set Of 3 Mt 26 Basic Turbidity Unit With Motherboard &Display With Integrated Chasis 27 Key Pad For Tb210ir / Tb211ir Turbidity Meter 28 Suction Assembly For Vacuum Pump Including Motor Assembly & Valves 29 Filtering Flask For Vacuumfiltration 30 Vacuum Filtration Funnel Holder Clamp 31 Quartz T Cell For Hydride Generator Of Aas 32 Membrane Dia 47 Mm, Ptfe For Hydride Generator-Thermo 33 Plumbing Kit For Aas Model Ice 3500 34 Pare Peristillic Pump Tubing 35 Gas Liquid Seperator Top Cap-Mk: Thermo 36 Iron Hollow Cathode Lamp 37 Arsenic Holow Cathode Lamp 38 Spider Of Spray Chamber 39 Buffel Of Spray Chamber 40 Massflow Control ( Mfc For Vp100 Ofic 3500 ) 41 Power Battery For Tb210ir Turbidity Meter, 9V Duralock Alkaline, Duracell Brand 42 Supply, Delivery, Installationof Uv-Visible Dual Beam, Programmable, Scanning & Suitable For Water Quality Analysis Spectrophotometer, 7“ High Contrast Colour Graphic-Display, Wavelength Range:190 To 1100 Nm, Accuracy: ±1.0 Nm; Measuring Methods: Absorbance, % Transmittance, Concentration; Detector: Dual Silicon Photodiodes; Connectivity: Ethernet, Usb B, Usb A For External Memory, Keypad, Barcode-Scanner, Pcl Compatible Printer. Light Source: Xenon Lamp;Cell Holders: Cell Holder- Adjustable Holder For Round Cuvettes: 13, 16 And 24 Mm ; Rectangular Cuvettes: 10, 20 And 50Mm & Auto Select Option . The Unit Should Be Capable Of Storing User-Defined Programming Methods & To Be Supplied With Programming Data Of Reday-To Use Spectrophotometric Reagent Tests Are To Be Pre-Loaded & In Usb Sticks. The Scope Of Work Includes Training Of Analysis Of Arsenic, Iron, Manganese To The User. The Unit Should Be Supplied With 10Mmpatlength Mateched Pair Cell Along With Power Cord, Operating Manual & Suitable Ups. Make: Thermo / Lovibond / Wtw Or Equivalent 43 Supply, Delivery, Installationof Turbidity Meter With Standard Calibration Solution & Accessories, Measuring Cuvette, Carrying Case & As Per Specification Given In Notice And Direction Of E.I.C.Range: 0, 01 - 1100 Ntu ( Auto Ranging ) . Resolution: 0.01 - 9.99 Ntu = 0.01 Ntu / 10.0 - 99.9 Ntu = 0.1 Ntu / 100 - 1100 Ntu = 1 Ntu. Calibration: 4 Point Auto Calibration. Unit Shall Be Supplied With Required Calibration Solutions, Operating Manual & As Per Specification In Notice & Direction Of E.I.C. Lovibond / Thermo-Eutech / Equiv 44 Supply, Installation & Demonstration Of Microprocessor Based Ph / Mv-Redox-Orp / Temperature 700 Meter With Automatic Temperature Compensation. The Unit Should Be Complete With Ph Electrode, Electrode Holder, Temperature Probe, Power Pack & Start Up Calibration Certified Buffer, Operating Manual & As Per Specification In Notice & Direction Of E.I.C.Thermo-Eutech / Equivalent 45 Supply, Delivery, Installation Distillation Unit, Glass, With Heater & In-Built Cut-Ff System With Reset Button, Horizontal Type Structure. All Glass Of Borosilicate Glass. , 4 Lit / Hour Capacity. To Work On 220 / 230 Volts. The Necessary Connector Tubing For Installation Are To Be Included In The Scope Of Supply. The Supplies To Be As Per Specification In Notice & Direction Of E.I.C. Riviera / Borosil / Equivalent 46 Supply, Delivery, Installation Of Microprocessor Based Analytical Balance, 210 Gm Capacity, 0.1 Mg Redability, With Internal Calibration Facility, Air-Shield, Ss Pan, Spirit Level Indicator & As Per Specification In Notice & Direction Of E.I.C. Shimadzu / Equivalent 47 Water Bath Made Of Ss, Single Hole, With Concentric Ring As Reduction Adaptor, With Self Ejecting Type Immersion Heater Suitable For Preparation Of Chromogenic Media. The Supplies To Be As Per Specification In Notice & Direction Of E.I.C. Relitech / Digilab / Equiv 48 Purulia