Secwan Noc Renovation Secwan Noc Renovation , Civil Works-Demolition Work---Dismantling Of Existing Partitions, Doors, False Ceiling, Floor Tiles, Light Fixtures, Work Stations, Power Receptacles, Ac Units And All Other Unwanted Materials And Installations All Complete And With Proper Cleaning And Keep The Waste Material At Proposed Location. Dismantled Materials Shall Be Completely Or Partially Removed From The Premises By Means Of Tractor / Proper Vehicle To Specified Location Or To Government Approved Dumping Area Time To Time As Directed By Customer And Project In-Charge. ( Approx-750Sqft ) , Providing And Filling 75Mm Thick Glass Wool Insulation Of Density 24 Kg Per Cum, Of Wrapped In Rp Tissues, As Per Manufacturers Specifications & Etc Complete As Directed By Engineer / Pmc. ( In Gypsum Partition ) , Brick Wall With Plastering. , Window Closures With Brick Work - Existing Windows Shall Be Closed With Suitable Size Brick / Work Including Plastering , Cement Plaster-Providing And Applying In 12Mm Thick Plaster On External Surface Of Rcc / Block Walls With Cement Mortar 1:4, Finished Rough To Take On Pop Punning. Rate Shall Includefor Scaffolding , Grooves, Sills, Pattas, Curing, Surface Preparation Before The Application Of Plaster, Providing And Fixing 26 Gauge Galvanized Chicken Mesh To A Width Of 150 Mm At The Junctions Of Masonry And Concrete Works Including Tying In Position By Using Suitable Nails / Clamps / Screws And As Directed Eic. Complete At All Levels. The Contractor Shall Make Good The Grooves, Pockets Etc. After Thescaffolding Is Removed. , Pop Punning-Providing And Applying Punning Up To 13Mm Thick Layer Of Super Fine Plaster Of Paris ( Anhydrous Gypsum ) Applied Over Selected Existing Plastered Surface On Walls And Columns Finished Smooth, Surface Prepared By Hacking, Sand Papering And Applying A Coat Of Cement Slurry If Required Including All Incidentals, Making Grooves As Directed, Pattas, Sills, Etc. Complete. The Finished Surface Should Be Smooth And In Perfect Level So As To Avoid Unevenness And Ready To Take On Paint Etc. Complete As Directed By Engineer / Pmc. , Providing And Applying Three Coats Of Fire Retardant Paint Of Approved Make To All Internal Walls Of Approved Colour Over A Coat Of Water Based Primer Including Preparation Of Surface By Thorough Cleaning And Wetting And Applying Readymade Putty Of Approved Make Etc. Complete As Directed By Engineer / Pmc. , Plastic Acrylic Emulsion. Providing And Applying Three Coats Of Plastic Emulsion Paint Of Approved Make To All Internal Wall, Ceilings, Of Approved Colour Over A Coat Of Water Based Primer Including Preparation Of Surface By Thorough Cleaning And Wetting And Applying Readymade Putty Etc. Complete As Directed By Engineer / Pmc. , Texture Paint. Providing And Applying Two Coats Pigmented Surface Texture Of Desired Shade At All Heights To Give An Even And Uniform Shade As Per Manufacturers Specification Of Approved Make Etc. Complete As Directed By Engineer / Pmc. Rate Shall Include Preparation Of Base Surface, Watering Before And After Application. , False Ceiling-Providing & Fixing Of Armstrong Suspended Ceiling System With Armstrong Fine Fissured, Mineral Fibre Tiles ( Micro Look Edge ) . The Tiles Having With Humidity Resistance Of 99%, Light Reflectance >85%, Nrc = 0.6, Sound Attenuation = 35Db, Thermal Conductivity K = 0.052 - 0.057 W / Mk, Colour White, Fire Performance Class 0 / Class 1 ( As Per Bs 476 Pt - 6&7 ) / Class A ( As Per Astm E 84 ) In Module Size Of 600Mm X 600Mm X 16Mm Laid On 15Mmxl - Hot Dipped Galvanized Steel Suspension System Having Rotary Stitching On The Main Runner, 1200 Mm & 600 Mm Cross Tees. Installation: To Comprise Main Runner Spaced At 1200Mm Centers Securely Fixed To The Structural Socket By Approved Hanger At 1200Mm Maximum Centre. The Last Hanger At The End Of Each Main Runner Should Not Be Greater Than 450Mm From The Adjacent Wall. As Per Approved Make. Flush Fitting 1200Mm Long Cross Tees To Be Interlocked Between Main Runners At 600Mm Centre To Form 1200 X 600 Mm Module. Cut Cross Tees Longer Than 600Mm Require Independent Support. 600 X 600Mm Module To Be Formed By Fitting 600Mm Long Flush Fitting Cross Tees Centrally Between The 1200 Mm Cross Tees. Perimeter Trim To Be Armstrong Wall Angles Or Channel, Secured To Walls At 450 Mm Maximum , Providing And Fixing Unitile Solid Fill ( Usf ) , 35Mm Thick, Grade 1500 Panel With Top Performance. Hpl Antistatic Laminate With Esrg Under Structure System Suitable For Finish Floor Height Of Up To 450Mm With 1800 Kg / Sq.M Udl A Structural Performance And Testing Should Comly With Masterspecs & Cisca Fire Standards As Per Bs 476 Part 6 & 7 Electrical Standards Should Comply With Ansi Astm And Nfpa 99. Panels: The Inner Empty Core Of The Panel Is Injected With A Light Weight Fire Retardant, Non Combustible Cementitious Compound At High Pressure To Fill In All The Crevices Of The Panel And Ensures Support Of Not Less Than 90% Of The Top Surface Area Of The Panel. The Panel Shall Have Located Corner Holes On All Edges For Bolting The Panel To The Substructure To Form A Rigid Monolithic Smooth Leveled Floor. Pedestal: The Pedestal Head Assembly Shall Consist Of A 75 X 75 Mm X 3.5 Mm Embossed Head Mechanically Riveted To A 100Mm Long 19 Mm Dia Rolled Formed Stud And 2 Check Nuts For Level Adjustment And Arresting Vertical Movement. The Pedestal Head Shall Consist Of An Anti-Vibrational Pvc Cap, For Panel And Stringer Location. The Pedestal Base Assembly Shall Consist Of 22.20 Mm Od Pipe Of Thickness 1.6Mm Mechanically Locked On A Press For Perpendicularity And Then Welded To A Base Plate Of 100 X 100 X 2Mm Thick With Stiffening Folds. The Sub Structure Assembly Shall Be Suitably Anchored To The Floor With Suitable Adhesive Or Fastener As Recommended By The Manufacturer. All Steel Components Shall Be Zinc Electro Plated. Stringers: The Stringer Is Hot Dipped Galvanized Steel Cold Rolled Construction Specially Designed With Ribs Embossed On 3 Sides For Strength, Lateral Stability, And For Enhanced Rolling Loads Performance And To Support The Panels On All Four Sides For Alignment. The Stringer To Have A Counter Sunk Holes At Both Ends To , Supply Air Grill / Perforated Tiles With Vcd - Providing And Fixing 600Mm X 600Mm Ms Powder Coated To Specified Colour Supply Grill ( Perforated Tiles ) With Vcd, And Open Area Ratio Of 55% As Per Sample Approved , Providing & Fixing Of Thermal Insulation With 19Mm Thick Aluminium Foil Faced Nitral Rubber Class O Insulation Sheet Of Following Thickness Under The False Floor Area On True Floor And Vertical Wall / Partition Area.The Joints Shall Be Sealed With 50 Mm Wide And Self Adhesive Pvc / Aluminium Tape Complete As Required. , Providing & Fixing Of Thermal Insulation With 19Mm Thick Aluminium Foil Faced Nitral Rubber Class O Insulation Sheet Of Following Thickness Above The False Ceiling Area On The True Ceiling And Vertical Wall / Partition.The Joints Shall Be Sealed With 50 Mm Wide And Self Adhesive Pvc / Aluminium Tape Complete As Required. , Single Leaf 4 Hrs Fire Rated Metal Door Of Size 900 X 2100 Mm , Single Leaf 4 Hrs Fire Rated Metal Door Of Size 1200 X 2400 Mm Emgency Door With Panic Bar , Fine Finished Stainless Steel Framed Double Glazed Fixed Vision Panel, 6Mm Thick 4 Hour Fire Rated Glass For Internal Pane, 12Mm Vaccum Filled Gap, 6 Mm Thick Clear Toughen Glass External Pane; Including Fittings, Fixings And All Necessary Accessories With Perfect Finish And Aisthetical Look All Complete. All Mateials Used For Fame And Fitiing Shall Also Be Fire Rated. Ss Frame Shall Be Provided For All Four Side Of The Glass, Ss Frame Shall Be Mat Finished, 304 Grade. Combination Of Sqare And Rectangular Hollow Sections To Make U Shaped Section Using Ss Continuous Welding Without Any Gaps And Shall Be Grinded And Polished So As To Look Like A Single Matfinished Ss Profile. Vacuum Glass Unit Shall Be Removable From Inside Of The Room For Replacement Or Repair When Require. Gap Between The Vacuum Glass Unit And The Ss Frame Shall Befilled With Transparent Type Silican Sealant With Uniform Spacing. Ss Sections: Grade 304, Sizes 20X50, 20X40 And 20X20 Equal Length - Each Approximately 20 Ft - Total Size Of The Vision Panel: 1200Mmx1800mm Glazed Panel Including Ss Frame. , Fine Finished Stainless Steel Framed Double Glazed Fixed Vision Panel, 6Mm Thick Clear Toughen Glass For Internal Pane, 12Mm Vacuum Filled Gap, 6 Mm Thick Clear Toughen Glass For External Pane; Including Fittings, Fixings And All Necessary Accessories With Perfect Finish And Aisthetical Look All Complete. All Materials Used For Fame And Fitiing Shall Be Of Ss. Ss Frame Shall Be Provided For All Four Side Of The Glass, Ss Frame Shall Be Mat Finished, 304 Grade. Combination Of Sqare And Rectangular Hollow Sections To Make U Shaped Section Using Ss Continuous Welding Without Any Gaps And Shall Be Grinded And Polished So As To Look Like A Single Matfinished Ss Profile. Vaccum Glass Unit Shall Be Removable From Inside Of The Room For Replacement Or Repair When Require. Gap Between The Vaccuum Glass Unit And The Ss Frame Shall Befilled With Transparent Type Silican Sealant With Uniform Spacing. Ss Sections: Grade 304, Sizes 20X50, 20X40 And 20X20 Equal Length - Each Approximately 20 Ft - Total Size Of The Vision Panel: 1200Mmx1800mm Glazed Panel Including Ss Frame. , Providing And Supplying Work Stations Of Specified Size Made Of 18 Mm Thick Commercial Plywood For Top, Side Support, Drawer Unit, Drawer Facia. 12 Mm Thk. Commercial Plywood For Table Appron, Drawer Sides And Back, 6 Mm Thk.Commercial Plywood For Drawer Bottoms. All Internal Surfaces Of Table, Appron, Drawers, ( All Sides, Bottom And Top ) Drawer Box To Be Finished With 0.8 Mm Thk. Approved Colour Laminate. All External Surfaces Of Table Including Top, Sides, Drawer Box, Drawer Facia To Be Finished With 1 Mm Thk. Approved Colour Laminate. All Drawer To Run On Approved Quality Telescopic Drawer Channels Of Hafele, Hettich Or Ebco, Complete Accessories In All Respect Including Approved Quality Metal Keyboard With Telescopic Channel, Godrej / Enox Drawer Locks, D Shape .S.S. Brass Bush Finished Handles For Drawers. Arrangement For C. P. U., Wire Manager For Computer. And 100 Mm X 40 Mm Teak Wood Foot Rest With French Polishing As Per Design And Instructions By Customer. Managers And Chanels And Covering Plates Shall Be Provided For Along The Full Lenghth Of Workstation For Installing Network Terminals And Power Sockets. Dimension: Workplane Depth: 600 Mm. Height: 750Mm, Wall Side Vertical Section: 1200Mm. Side Vertical Section 1200Mm. , 3 – Drawer Pedestal –Drawer Boxes Of Size 685Mm Ht., 390Mm Width And 450Mm Deep, The Outer Casing ( Except Back ) And Drawer Fronts Of These Pedestals Are Made From 18Mm Thick Pre-Laminated Particle Board Grade Ii & Type-Ii ( Is 12823: 1990; Reaffirmed 2005 ) Plb Finshed With 0.8 Mm Thk Laminate. The Casing Back Is Made From 9 Mm Thick Plb. The Box Drawers Have An External Fascia Height Of Approx. 150Mm And Filing Drawers Have An External Fascia Height Of Approx. 300Mm. The Drawer Movement Is On Full-Panel Type Drawer Runners Having Rollers, Which Also Form The Sides Of The Drawer Tray. These Runners Are Of The Single Extension Type For The Box Drawers And Double Extension Type For The Filing Drawer. The Height Of These Panel Slides / Sides For Box Drawers Is 86 Mm And It Is 125 Mm For The Filing Drawer. The Back And Bottom Of Drawer Trays Are Made From 9Mm Thick Plb. The Filing Drawers Are Provided With A Cradle Filing Arrangement. The Pedestals Are Provided With A Central Multi-Drawer Locking System And Stainless Steel Handles In The Matt Finish For All Drawer Fascia. Pedestals Are Provided With 4 Nos.Nylon Spacers 10Mm Ht. , Providing And Supplying Medium Back Chairs As Per Following Specification. The Chairs Has A Back Inner / Outer Shell Made Out Up Of Polypropylene Having Snap Type Fittings. Moulded Foam ( 48 Density ) Is Used On The Seat And Back. A Hot Presses Plyood Seat ( 12 Mm Thick ) Is Used As Base. The Arm Rest Used Is Made Up Of Soft Polyurethane ( 250 Density ) Having Mild Steel Insert. The Tilting Mechanism Used Is Having Only Back Movement Lockable At The Front Position. The Seat To Back Connecting Mild Steel Plate Is 10 Mm Thick. The Handle Connecting Mild Steel Plate Is 5 Mm Thick. A Seat Outer Made Up Of Polypropylene Is Used For Asthetic Appeal. An Imported Gas Lift Mechanism Is Used For Seat Height Adjustment. A Mild Steel Powder Coated Base ( 630 Mm Wide ) Is Used Having A Load Capasity Of 800 Kgs. Twin Wheel Nylon Castore Are Used Havinga Load Bearing Capasity Of 50 Kgs. Per Caster. , Boxing With Toughened Glass Vision Panel For Novec 1230 Cylinders. Providing And Fixing 75Mm X 50Mm Powder Coated Aluminium Box Section Of Specified Colour. 6Mm Thoughed Glass To Be Used And Fixed With Proper Chemical Treated Rubber Gasket. Boxing Shall Be Openable With Vision Glass And Hinged Frame. Rate Includes All Hardware, Handles, Locking System, Etc Complete. , Providing And Fixing Of Step Specified Size As Per The Drawing And Instructions On Site Using Fire Rated Light Weight Blocks And Finished With Smooth Cemet Plaster. Toplayer Of The Step To Be Finished With 19 Mm Thick Granite Stone And Anti Skid Taping At Every 300 Mm Interval And On Each Step. Rate Inclueds Proper Curing And Any Shutering And Supports Required. – 2 Nos , Leveling Of Floor Using Cement Mortar Wth Average 20 Mm Thick Cement Mortar Mix Ratio 1:4 ( 1 Cement : 4 Sand ) Including Preparing Surfaces, Spreading Cement Slurry Using Cement 2Kg / Sqm Over Prepared Surface & 4.5 Kg / Sqm Over Bedding. Joints To Be Cleaned And Grouted With Matching Colour Cement Grout Or Approved Colour Readymade Grout With Curing, Machine Polishing, Cleaning Etc. , Providing And Laying 2Mm Thick Antistatic Vinyl Flooring Of Aproved Make. En 685 : 1996 Homogeneous Conductive Vinyl Floor Of 2Mm Thick And With Reaction To Fire As Per Iso 9239-1, Flexibility Of <20Mm Pass, Slip Resistance Of Class Ds Pass, Abrasion Resistance - Wear Group P Pass, Residual Identation - 0.1Mm Static Load 800 Psi, Light Fastness - Blue Wool Standard 6, Thermal Resistance - <0.00512 M2 K / W & Smoke Density - < 450. Instalation As Per Manufactorors Catalog Mathod. , Providing And Laying In-Position Nano Polished Vitrified Tiles Of Size 600 X 600 Mm Of Approved Make And Colour, Fixing The Same Over Average 20Mm Thick Cm 1:6 Bedding Using Approved Quality Tile Adhesive Of Bal Endura / Roff Or Equivalent Approved Make, Uniformly In Line And Level In Approved Design And Filling The Joints With Eppoxy Based Joint Filling Compound Of Matching Shade Curing The Joints, Removing Of Existing Tiles If Required & Carting Away Unserviceable Material / Debris To A Place Approved By Municipal Corporation Etc As Per Instruction Of Engineer In- Charge Complete. Make: Kajaria / Somany / Simpolo Or Equivalant As Per Sample Approved , Protection Of Tiling In Common Areas And Floor Passage With Plastic Cover Sheet & Pop Filling Over It. , 100Mm Ht Aluminium Profile Skirting , 100Mm Ht Vitrified Tile Skirting , For Ms Structural Steel Structural Frame At 4 Meter Height Including Chanels, Angles, Fasteners Etc. All Ms Steel Sections Shall Be Coated With Anti-Corrossive Primer And Paint , Providing And Fixing 20Mm Thick Cement-Based-Fire- Resistant Board ( Bison / Sherra Or Equivalent Approved Make ) On The Existing Windows / Openings With Proper Aluminium Framing All Round To Close The Windows / Openings Permanently Wherever Required And Ditected. , Making Of Cut Out In Brick Partition, Gypsum Cutting Or Any Of The Opening Which Is Necessary To Passing The Cable & Cable Tray Where And There. The Rate Shall Be Inculsive Of Making The Cutout And Refinish The Surface Smooth & All Necessary Structure Supports Like Sacf-Floding Etc. , Supply & Fixing Of Fire-Sealing Treatment In The Annular Space In The Above Mentioned Openings, After All The Relevant Services ( Pipes, Trays, Cables Etc. ) Have Been Passed By Other Agencies As Per Following Procedure Using Tested & Approved Materials: 1. Cutting To Shape ( As Per The Profile Of The Annular Space In The Openings ) And Fixing A Certified 4-Hour Fire Rated, 50 Mm Thick Mineral Wool Board Of Density 144 Kg. / Sqmtr, On Both Sides Of The Opening, 2. Coating The Above Mineral Wool Board And Adjoining Part Of The Wall, With 1.5 To 2 Mm Thick Fire Coating Having Minimum 4 Hour Fire Rating. 3. The Material Used And Procedure Of Fire-Sealing Done As Above, Should Have Been Tested At Cbri Roorkee As Per Is-12458 & Bs-467 As Required. A Certificate Complying To Other Equivalent Standard From Some Other Valid Test-Lab Would Also Be Acceptable. 4. Providing And Fixing A Laminated Signed Certificate Of Approval From The Oem, On The Wall Near Each Opening On Both Sides. The Tests Certificate From A Third-Party-Accredited Laboratory, Of Similar Fire Sealing Of Wall Openings, Should Be Submitted And Got Approved From Consultant Before Starting The Work At Site. Only The Cross-Sectional Area Of Each Opening Will Be Considered For The Purpose Of Measurement Of The Sealings Done On Both Sides Of The Brick-Wall. For The Sake Of Clarity, The Sealing Done On Both Faces Of The Wall, Shall Not Be Measured Twice And It Will Be Considered Only Once. , Debris Removal Removing All The Waste Generated At Site By Means Of Tractor / Proper Vehicle To Specified Location Time To Time As Directed By Client And Project Incharge. , House Keeping Providing Housekeeping Labours And Keep The Site Clean Till The Handover With Proper Supervission. , Logo & Signages Room Name, Warning Signs, Exit Signs, Caution Signs Labelling Etc , Drawings Display Board Layout & Sld Paseted On Acrilic Board Supported On Wall With Ss Studs , Top / Bottom Cable Entry For Incoming And Outgoing Feeders. Fabricated Out Of 14Swg Crca Sheet. Rotary Fd Kit Shall Be Provided For All Mccbs. A Class B Spd, 10 / 350?S, 50Ka, With Built In Disconnector Shall Also Be Provided For Each Bus Bar Of This Panel As Per Electrical Schematic Diagram. 1 ) Busbars: 250A 4P Cu. Busbar For Phase And Neutral - 1No. Earth Bus - 25X3 Cu. 2 ) Incomer 1: 200A, 35 Ka 4P Mccb Lsig Type With No / Nc Contacts For On / Off / Trip Communication To Bms.-1No Meters & Indications: 3Phase Digital Combination Meter Em6400ng Of Schneider / Conzerv With Volts, Amps, Kw, Va, Kwh, Kvah, Pf, Thd Etc With 3Nos Metering Cts Class1, 15Va, 200 / 5A, Rs485 Modbus Interface - 1Set Red, Yellow & Blue Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 1Set. Red / Green / Ambur, On / Off / Trip Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 1Set 3 ) Incomer 2: 200A, 35 Ka 4P Mccb Lsig Type With No / Nc Contacts For On / Off / Trip Communication To Bms.-1No Meters & Indications: 3Phase Digital Combination Meter Em6400ng Of Schneider / Conzerv With Volts, Amps, Kw, Va, Kwh, Kvah, Pf, Thd Etc With 3Nos Metering Cts Class1, 15Va, 200 / 5A, Rs485 Modbus Interface - 1Set Red, Yellow & Blue Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 1Set. Red / Green / Ambur, On / Off / Trip Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 1Set. 4 ) Bus Coupler: 200A, 35 Ka 4P Mccb Lsig Type -1No Red / Ygreen / Ambur, On / Off / Trip Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 1Set. 5 ) Outgoings: 100A 4P Mccb 35Ka -4No 40A 4P Mccb 35Ka -4No 32A 4P Mccb 25Ka -2No Meters & Indicators For Outgoings ( 1 Set For Each Outgoings ) : Red, Yellow & Blue Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch Red / Green / Ambur, On / Off / Trip Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch. 6 ) Interlocking: Electrical & Mechanical Interlock Shall Be Provided Between Incomers And Bus Coupler , 3 ) Incomer 2: 200A, 35 Ka 4P Mccb Lsig Type With No / Nc Contacts For On / Off / Trip Communication To Bms.-1No Meters & Indications: 3Phase Digital Combination Meter Em6400ng Of Schneider / Conzerv With Volts, Amps, Kw, Va, Kwh, Kvah, Pf, Thd Etc With 3Nos Metering Cts Class1, 15Va, 200 / 5A, Rs485 Modbus Interface - 1Set Red, Yellow & Blue Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 1Set. Red / Green / Ambur, On / Off / Trip Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 1Set. 4 ) Bus Coupler: 200A, 35 Ka 4P Mccb Lsig Type -1No Red / Ygreen / Ambur, On / Off / Trip Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 1Set. 5 ) Outgoings: 100A 4P Mccb 35Ka -4No 40A 4P Mccb 35Ka -4No 32A 4P Mccb 25Ka -2No Meters & Indicators For Outgoings ( 1 Set For Each Outgoings ) : Red, Yellow & Blue Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch Red / Green / Ambur, On / Off / Trip Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch. 6 ) Interlocking: Electrical & Mechanical Interlock Shall Be Provided Between Incomers And Bus Coupler ( As Per The Site Requirement ) , Dc Redundant Ups Panel Top / Bottom Cable Entry For Incoming And Outgoing Feeders. Fabricated Out Of 14Swg Crca Sheet. Rotary Fd Kit Shall Be Provided For All Mccbs. 1 ) Busbars: 125A 4P Cu. Busbar For Phase And Neutral - 1No. Earth Bus - 25X3 Cu. 2 ) Incomer 1: 125A, 35 Ka 4P Mccb Lsig Type With No / Nc Contacts For On / Off / Trip Communication To Bms.-1No Meters & Indications: 3Phase Digital Combination Meter With Volts, Amps, Kw, Va, Kwh, Kvah, Pf, Thd Etc With 3Nos Metering Cts Modbus Interface - 1Set Red, Yellow & Blue Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 1Set. Red / Green / Ambur, On / Off / Trip Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 1Set. 3 ) Outgoings: 100A 4P Mccb 35Ka -1No 16A 4P Mcb 10Ka -2No Meters & Indicators Only For 100A Mccb Outgoings:Red / Ygreen / Ambur, On / Off / Trip Led Indication Lamps 3Nos, 2A Control , Dc Pdu A Top / Bottom Cable Entry For Incoming And Outgoing Feeders. Fabricated Out Of 16Swg Crca Sheet 1 ) Busbars: 100A Tp+2N, Cu. Busbar For Phase And Neutral - 1No & Insulated Earth Bus For Equpment Earthing. 2 ) Incomer: 80A 4P, 25Ka Mccb-1No. 3 ) Meters & Indications: 3Phase Digital Combination Meter Em6400ng Of Schneider / Conzerv With Volts, Amps, Kw, Kva, Kwh, Kvah, Pf, Thd Etc With 3Nos Metering Cts Class1, 15Va, 800 / 5A, Rs485 Modbus Interface - 1Set Red, Yellow & Blue Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 1Set. Red / Green / Ambur, On / Off / Trip Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 1Set. 4 ) Outgoings: 32A Dp, D-Curve Mcb - 9Nos 16A 4P, D-Curve Mcb - 2Nos , Pdu B Top / Bottom Cable Entry For Incoming And Outgoing Feeders. Fabricated Out Of 16Swg Crca Sheet 1 ) Busbars: 100A Tp+2N, Cu. Busbar For Phase And Neutral - 1No & Insulated Earth Bus For Equpment Earthing. 2 ) Incomer: 80A 4P, 25Ka Mccb-1No. 3 ) Meters & Indications: 3Phase Digital Combination Meter Em6400ng Of Schneider / Conzerv With Volts, Amps, Kw, Kva, Kwh, Kvah, Pf, Thd Etc With 3Nos Metering Cts Class1, 15Va, 800 / 5A, Rs485 Modbus Interface - 1Set Red, Yellow & Blue Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 1Set. Red / Green / Ambur, On / Off / Trip Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 1Set. 4 ) Outgoings: 32A Dp, D-Curve Mcb - 9Nos , 40A 4P Manual Changeover Switch With Enclosure Top & Bottom Cable Entry For Incoming And Outgoing Feeders. Fabricated Out Of 16Swg Crca Sheet 40A 4P Manual Changeover With Necessary Protections As Per Local Electrical Inspectrate Standard. Indicators Red, Yellow & Blue Led Indication Lamps 3Nos, 2A Control Fuses With Toggle Switch - 2Set Red / Green, Source On / Off Led Indication Lamps 2Nos, 2A Control Fuses With Toggle Switch - 2Set , Mcb Db- Utility Db A Incomer: 32A, 4P, Mcb With Rccb 300Ma. Outgoing: 2 Nos - 1P, 16 A Mcbs 16 Nos - 1P, 10 A Mcbs , Mcb Db- Utility Db B Incomer: 32A, 4P, Mcb With Rccb 300Ma. Outgoing: 2 Nos - 1P, 16 A Mcbs 16 Nos - 1P, 10 A Mcbs , Mcb Db- Ups Incomer: 16A, 4P, Mcb Outgoing: 12 Nos - 1P, 10A Mcbs , Mcb Db- Eldb Incomer: 10A, 2P, Mcb With Rccb 300Ma. Outgoing: 4 Nos - 1P, 6A Mcbs , Mcb Box- Pac A & B Mcb: 32A, 4P, Mcb , M.S. Powder Coated Box ( 600 X 300 X 150 Mm ) With Copper Busbar And Suitable Sized And No Of Holes To Connect Earthing Conductors, Provision Of Double Earthing Conectivity Of Cu Flexible Cable With Earthing Station As Required. Withfront Door Acrylic Sheet. Dedicated Earth To Be Inscribed On The Cover Of The Enclosure. , M.S. Powder Coated Box ( 450 X 300 X 150 Mm ) With Copper Busbar On Insulated Supports And Suitable Sized And No Of Holes To Connect Earthing Conductors, Provision Of Double Earthing Conectivity Of Cu Flexible Cable With Earthing Station As Required. With Front Door Acrylic Sheet. Dedicated Earth To Be Inscribed On The Cover Of The Enclosure , M.S. Powder Coated Box ( 600 X 300 X 150 Mm ) With Hot Dip Galvanised Busbar On Insulated And Suitable Sized And No Of Holes To Connect Earthing Conductors With Front Door Acrylic Sheet. Dedicated Earth To Beinscribed On The Cover Of The Enclosure. , 600X150x10mm Cu. Busbar On Insulated Supports And Necessary Holes To Connect Earthing Conductor , Earth Pit With Cu Plate, 40 Mm Gi B Class Pipe Of 3 Meters Length With Funnel Arrangement Excluding Civil Work And Manhole Chambers , Earthing Strips ( All Terminations And Joints Shall Be Tinned Or Coated With Anti-Corrosive Materials Which Does Not Affect The Conductivity ) -25X6 Mm Cu. Strip , 25X3 Mm Cu. Strip With Sleeve , 25X3 Mm Cu. Strip , 10X2 Mm Cu. Strip , 8 Swg Cu Wire , 4Mm Braided Cu. Wire With Clamps And Lugs , Earthing Links , Frp Insulators, Suitable For 433V, With Necessary Fasteners To Support Earth Strips. , Earthing Cables-1Cx120 Sqmm Cu.Conductor Pvc Flexible Cable ( Green Colour ) , End Termination , 1Cx95 Sqmm Cu.Conductor Pvc Flexible Cable ( Green Colour ) , End Termination , 1Cx35 Sqmm Cu.Conductor Pvc Flexible Cable ( Green Colour ) , End Termination , 1Cx25 Sqmm Cu.Conductor Pvc Flexible Cable ( Green Colour ) , End Termination , 1Cx10 Sqmm Cu.Conductor Pvc Flexible Cable ( Green Colour ) , End Termination , 1Cx6 Sqmm Cu.Conductor Pvc Flexible Cable ( Green Colour , End Termination , 1Cx4 Sqmm Cu.Conductor Pvc Flexible Cable ( Green Colour ) , End Termination , Pvc Sleave For Earth Cables-Pvc Sleave For 1Cx25 Sqmm Cu Flexible Cable ( Green Colour ) , Pvc Sleave For 1Cx10 Qmm Cu Flexible Cable ( Green Colour ) , Pvc Sleave For 1Cx6 Sqmm Cu Flexible Cable ( Green Colour ) , Pvc Sleave For 1Cx4 Qmm Cu Flexible Cable ( Green Colour ) , Ladder Type Cable Tray-Gi Traysize :300 Mm X 50 Mm , Gi Tray Size :150 Mm X 50 Mm , Gi Tray Size:300 Mm X 50 Mm With Perforated Cover , Gi Tray Size:150 Mm X 50 Mm With Cover , Raceway :300 Mm ( W ) X 150 ( H ) Mm With Perforated Cover , 200X50mm Cable Tray , 300X50mm Cable Tray , 450X50mm Cable Tray , 300 Mm Wide Ladder Type Data & Network Cable Tray , Steel Items-Gi, For Supporting Nw Cable Trays, Like Angle Iron, Hitech Rods, Bolts, Nuts, Anchor Bolts Etc., , 36 W Led Recess Mounted Luminaire Making Earthing Conection Complete To Be Recessed In False Ceiling With All Necessary Hardwares , 12 W Round Led Down Light Pressure Die Cast Aluminium Fixture To Be Recessed In False Ceiling With All Necessary Hardwares, Chains, Hook Etc. Complete. , Led Tube Light 1 X 7 W ( 560 Lumens ) , Auto Self Glow Exist Sinage ( Prolite ) , 1100 V Grade , 3Rx2.5 Sq.Mm Wires, Multi Strand Copperin 19Mm Dia Frls Conduit. ( From Dbs, Up The Switch Point ) . , 3Rx1.5 Sq.Mm Wires, Multi Strand Copperin 19Mm Dia Frls Conduit. ( For Looping Of Lights ) , 3Cx2.5 Sq.Mm Cable ( Yy ) With Pvc-Frls , 3Cx4 Sq.Mm Cable ( Yy ) With Pvc-Frls , 32Mm Dia Frls Conduit , 25Mm Dia Frls Conduit , 1 Light Pointcontrolled By A 6 A Switch , 2 To 3 Lights Controlled By A 6 A Switch , 3 X 6A Multi Socket Controlled By 16A Switch , 2 X 6A Multi Socket Controlled By 16A Switch , 1 X 6 / 16A Twin Socket Controlled By 16A Switch , 1 X 6A Multi Socket Controlled By 6A Switch , 32A 3Pin Iec 309 To Be Overhead Raceway Above It Racks , 16A 3Pin Iec 309 Socket With 32A 2P C-Curve Mcb With Box , Cables & End Terminations.- ( Ac Power Distribution ) -4Cx120 Sqmm Al. Ar. Xlpe Insulated Frls Cable , End Termination , 4Cx95 Sqmm Al. Ar. Xlpe Insulated Frls Cable , End Termination , 4Cx70 Sqmm Al. Ar. Xlpe Insulated Frls Cable , End Termination , 4Cx16 Sqmm Al. Ar. Xlpe Insulated Frls Cable , End Termination , 4Cx10 Sqmm Al. Ar. Xlpe Insulated Frls Cable , End Termination , 3Cx6 Sqmm Cu. Un. Ar. Pvc Flexible Frls Cable , End Termination , 3Cx4 Sqmm Cu. Un. Ar. Pvc Flexible Frls Cable , End Termination , 3Cx2.5 Sqmm Cu. Un. Ar. Pvc Flexible Frls Cable , End Termination , 1Cx35 Sqmm Cu.Conductor Pvc Flexible Frls Cable , End Termination , 1Cx25 Sqmm Cu.Conductor Pvc Flexible Frls Cable , End Termination , 1Cx10 Sqmm Cu.Conductor Pvc Flexible Frls Cable , End Termination , 1Cx6 Sqmm Cu.Conductor Pvc Flexible Frls Cable , End Termination , 1Cx4 Sqmm Cu.Conductor Pvc Flexible Frls Cable , End Termination , 1Cx2.5 Sqmm Cu.Conductor Pvc Flexible Frls Cable , End Termination , 3C X 4 Sq.Mm Copper Ywy , End Termination , 3Cx2.5 Sq.Mm Copper Ywy , End Termination , Miscellaneous--Shock Treatment Chart Laminated , First Aid Kit- , Rubber Mat 1100V Grade Isi Approved 2 M X 1M. , Statutoryapprovals-Preparation And Submission Of As Built Drawings, ( Hard And Soft Copy-6Sets ) Additional Alternation Post Completion Of Project. It Shall Be The Resposnibility Of The Partner To Submit The Energisation Order Certificate From Kerala State Electrical Inspectorate Along With The Final Invoice ( Excluding Statutory Fees ) , Professional Charges Towards Filing Application, Preparation Of Drawings In Necessary Formats For Approval, Follow Up And Arranging Approval Of Drawings, Scheme By Local Electricity Authority, Electrical Inspectorate And Kerala State Electricity Board. ( Excluding Statutory Fees ) , Rack Mountable 20 Kva Online Ups In N+1 Parallel Configuration ( N+1 For 20Kva ) With Input Controls & Paralleling Panel, Expandable Upto 60Kva ( Including Supply & Installation ) Pf>0.95, Effiency:>95%415V / 415V, K-13 Rated Isolation Transformer, Delta-Star With Soft Starter, Suitable Mccb Indicators ) , Battery Bankwith Stand And Inter Connection Cable For Approx. 45 Min. Backup With 80% Load Each , Ms Open Rack And Accessories , Unit- 6.5 Trbottom Throw Pac With Digital Scroll. Floor Mounted, Bottomdischarge Type , Single Circuit Air-Cooled Dx Type Precision Air Conditioners Of23 Gross Cooling Capacity At3550 Cfm At Return Air Tempareture Of 24 Deg C Db & 50% Rh And Outdoor Ambient Condition @37 Deg C With R410 A Refrigerant Gas ) . Indoor Unit : The Indoor Unit Shall Comprise Of Digital Scroll Compressor, Variableevaporator Fan Complete With Backward Curved Type With Ec Motor, Evaporator Dx Cooling Coil , Microprocessor Controllers, Thermalexpansion Valves, Driers, G4 Filter, Suction And Discharge Piping, Internal Power And Control Wiring, Crankcase Heaters, Hp / Lp Cut Outs, Power And Control Contacts And Other Electrical Accessories. Outdoor Condenser Unit : The Outdoor Condenser Unit Shall Comprise Of Condenser Fans & Motor, Condenser Cooling Coil ( Copper Coil With Aluminium Fins ) And Isolator Switch. , Stand For Both Indoor And Outdoor Unit , Refrigerant Gas, R-410A , 3 C X 2.5 Sq.Mm Copper Armoured Cable ( From Idu To Odu ) , 4 C X 10 Sq.Mm Copper Armoured Cable ( Power Cable ) , Interconnecting Copper Piping Between Indoor & Outdoor Unit. Copper Piping Will Be Duly Insulated , Interconnecting Copper Piping Between Indoor & Outdoor Unit. Copper Piping Will Be Duly Insulated. ( Return ) , 25 Mm -40 Mm Dia Hdpe Drain Pipe With Insulation , 25 Mm -40 Mm Dia Hdpe Drain Pipe Without Insulation , 1.5 Trsplit Ac , Indoor And Outdoor Units With Necessary Cabling Indoor, Outdoor Stand, Stabilizer , 1 Zone Vesda Panel Having 250 Sqm Coverage Addressable Type , Vesda Pipe Circuit Cpvc Conduits And Fittings , Sampling Point , Sounder Cum Strobe , Fire Suppression-80 L Cylinder With Main Assembly, Electric Actuator, Manual Actuator, Pressure Guage, Warning Sign And 2 Nos Strap , Novec1230 Gas , Pressure Switch , Ms Seamless Pipe And All Fittings Including Painting As Per Oem Discharge Circuit Design , 2 Zone Gas Release Panel , Multi Smoke Detector , Response Indicator , Mcp , Sounder Cum Strobe , Manual Abort Switch , Manual Release Switch , 2C X 1.5Sqmm Frls Armoured Fire Cable ( Red ) , Fire Extinguisher-Supply Of Co 5 Kg. Fire Extinguisher , Supply Of 4 Kg. Abv Dry Powder Type Fire Extinguisher , Rodentrepellentcontrollerwith Bracket , Transducer With Accessories , 2 Core Transducer Cable With Conduit , Cctv--8 Channel Hd Nvr With 2Tb Internal Surveillance Grade Hdd And All Necessary Accessories , 2 Mp, 3.6Mm, 30 Mtr Ir, Dome Ip Camera , 18.5” Led Hd Monitor With Wall Bracket , Hdmi Cable With Pvc Conduit-20 Mtr , 9U Rack With Pdu And Mounting Hardware , Cat6 Cable , 20Mm Pvc Conduit With Accessories , Access Control System-4 Door Access Controller With Accessories , Biometric Cum Card Reader , Exit Switch , Emergency Door Release Switch , 1200 Lbs Em Lock For Double Door , 8 Core 0.5 Sqmm Shielded Cable , 2 Core 0.5 Sqmm Cable , 20Mm Pvc Conduit , Telephone Wiring-2Pair0.5Mmtelephonecablewithpvcconduitandall Accessories , Telephone Point With Font Plate & Back Box , 20 Pair Powder Coated M.S. Dp Box With Back Mount Frame, Front Lockable Door , Adc Krone Make Disconnection Module 2 / 10 , Adc Krone Make Magazine2 / 10 , 3Leg Gd Tube , Telephone , Environment Monitoring System-Dcimmonitoringconsolewithwebpageinterface Software , Temperature Cum Humidity Sensor , Smoke Sensor , 5 Mtr Wld Sensor , Sounder Cum Strobe , Gsm Modem , 18.5 Monitor With Wall Bracket , 10 Mtr Hdmi Cable , Cat6 Cable , 20Mm Pvc Conduit With Accessories , Water Leakage Detection System-Wld Controller With Bracket , 5 Mtr Wld Sensor, , Installation , Passive And Networking-24 Port Fully Loaded Patch Panel , Loaded Faceplate , Faceplate Backbox , Utp Patch Cord - Cat 6A - 1 Mtr , 15U Network Rack With Accessories For Isp , 42U Network Rack With Accessories , Testing Of Existing Fibre Cable , Shifting The Existing Fiber ( Including Splicing, Patch Cord, Liu ) And Other Noc Equipment To Renovated Area, Installation, Testing And Go-Live