Providing And Fixing Of Remote Cctv Surveillance System And To Make It Operational At 220 Kv Substation Handia Under T And C Circle Mpptcl Bhopal Providing And Fixing Of Remote Cctv Surveillance System And To Make It Operational At 220 Kv Substation Handia Under T And C Circle Mpptcl Bhopal , Cctv Surviellance System , Network Based Ip Dome (Indoor) Array Indoor Camera (2 Mpx,3.6 Mm) (2- Line) 36Ir Led, (Indoor) 1080 Pcat 6 Cable And Accessories With Installation) As Per Technical Specification Mentioned In Annexure-A Of Sony/Samsung/Hik-Vision/Hi-Safe Only Make Fitted At A Location To Monitor Control Room Operations Including Interconnection With Nvr As Per Direction Of Engineer In Charge And Mpptcl Terms & Conditions. Location:- Control Room, Battery Room, As Per Mpptcl T & C. , Network Based Ip Bullet (Outdoor) Array Outdoor Camera (4 Mpx 6.0 Mm, (2-Line) (3 Axis Adjustment) With 4 Ir Booms Led With Armoured Body To Sustain Surge Protection Up To 3Kva (Outdoor) 1080 Up To 2160P Cat 6 Cable And Accessories With Installation) As Per Technical Specification Mentioned In Annexure-B Ofsony/Samsung/Hik-Vision/Hi-Safe Only Make Fitted At A Location Inside Live Yard To Monitor The Functioning Of Bays 33/132/220 Kv Including Interconnection Wired Or Wirelessly With Nvr As Per Direction Of Engineer In Charge And Mpptcl T & C. • 1No. Unit For 8 33Kv Bay • 1No. Unit For 3 132Kv Bay • 1No. Unit For 2 220Kv Bay Note: (I) Camera To Be Operated With In The Live Yard With Heavy Induction From Transmission Line Up To 220Kv. (Ii) Body Should Be Armoured To Sustain The Surge Up To 3Kva, Location In Between The Live Substation. (Iii) System Installed Within The Live Yard Should Be Grounded To Avoid Any Fault During Any Surge Or In Between Any Impulsive Current/Voltage Within The Live Yard.Location: At 132/220Kv Gantry, Agt Or Double Agt Gantry Tower Camera Height Ranging 9-13 Metresto Cover Maximum Coverage Area And 33/132/220Kv Bays With Associate Accessories. , Network Based Ip Bullet (Outdoor) Fhd Array Outdoor Camera (4 Mpx, Veri Focal (2.8Mm To 12.00Mm Range) (2-Line) With Heavy Range Ir Boom, 1080 Up To 2160P Pcat 6 Cable And Accessories With Installation) As Per Technical Specification Mentioned In Annexure-C Of Sony/Samsung/Hik-Vision/Hi-Safe Only Make Fitted At A Location To Monitor Main Gate Including Interconnection With Nvr As Per Direction Of Engineer In Charge. Note: (I)Body Should Be Armoured To Sustain The Surge Up To 3Kva, Location In Between The Live Substation, Also Sustain The Radiant Temperature Of Transformer And Atmosphere Together. (Ii) System Installed Within The Live Yard Should Be Grounded To Avoid Any Fault During Any Surge Or In Between Any Impulsive Current/Voltage Within The Live Yard. Location And Area Coverage:Xmer Gantry, Agt Or Double Agt Gantry Tower To Cover Transformer Top, Feeders, Oil Tank And Associate Accessories Of Transformer. , Surge Protection Kit For Ip Camera Cctv System. Technical Specs As Mentioned In Annexure L , Network Video Recorder 4 Mpx Support (Nvr) (32 Channel Online Nvr ,P2p Built In Dns , Support Mobile Surveillance, Full Hd 1080P, Accessories4tb Hdd For Recording) As Per Technical Specification Mentioned In Annexure-C(Ii) Of Sony/Samsung/Hik-Vision/Hi-Safe Only Make Fitted With 4Tb Of Hard Disk Of Seagate/Wd Make Preferably Other Than Chaina Make For Storage Of Data In Control Room, At Local End Including Interconnection With Camera Installed At Different Locations, Interconnection With Modem, Local Display Unit As Per Direction Of Engineer In Charge. Installation Of Necessary Software & Application Program Etc. Compatible For Online Display Of Cctv Surveillance System Along With Facility For Online Operation Of Cameras Both At Local & Remote End With Provision For Security For Online View. , (P To Mp) Point (Camera) To Multipoint Connection (Nvr) Via Lan Wire Or Wireless System For Ptz Camera And Outdoor Cameras Placed At Control Room Building & Gantry Within Substation Yard, With 8 Port Lan Switch As Per Technical Specification Mentioned In Annexure-E Of Brands- Tenda/D-Link/Tp-Link (Wired Connection Via Cat6 Wire Will Be Preferred For The Indoor/Outdoor Camera And If It Exceed 30 Mtr From Nvr Than Wireless Connection Should Be Provided) Note: System Installed Within The Live Yard Should Be Grounded To Avoid Any Fault During Any Surge Or In Between Any Impulsive Current/Voltage Within The Live Yard And Can Sustain Surge Up To 2Kva. , A Switched-Mode Power Supply (Smps) 12V/1-10Amp As Per Technical Specification Mentioned In Annexure-F Note: Body Should Be Armoured And Grounded To Sustain The Surge Up To 2Kva, Location In Between The Live Substation. , Lan Switch: 16 Port Gigabit Switch Make Tenda, D-Link, Tp-Link, Cisco As Per Technical Specification Mentioned In Annexure –F. , Junction Box; Weatherproof Box For Lan Switch, Smps Power Board At Camera End As Per The Technical Specification Mentioned In Annexure-G , 4U Rack Box For Nvr And Lan Switch For Interconnection Of Nvr And Lan Switch Placed Inside The Control Room With Lock System As Per The Technical Specification Mentioned In Annexure-H , Fitting Material; Pole Mounting For P2p And Camera As Per Technical Specification Mentioned In Annexure-I , Power Board; Power Board With 3 Power Socket And Mcb For P2p And Smps As Per Technical Specification Mentioned In Annexure-J , 27 Inch (2160X1440) Ips Led Fhd Monitor As Per Technical Specification Mentioned In Annexure-K(I) Of Samsung/Lg/Sony/Hp Or Anyequivalentmake Preferably Other Than Chaina Make Fitted In Control Room At Local End For Display Of Camera Installed In Yard & Control Room Including Necessary Interconnections & Auxiliary Supply By Cabling As Per Direction Of Engineer In Charge , Cat 6 Cable (Actual Required After 20 Meters For Dome Camera And 30 Meters For Bullet As Well As Ptz Camera)