}

Provision Of Certain Sanctioned Work At Age B / R Beas Under Ge Kapurthala- 1 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc., But Excluding Ashlar Faci, kapurthala-Punjab

Statutory Bodies & Commissions/Committees has published Provision Of Certain Sanctioned Work At Age B / R Beas Under Ge Kapurthala- 1 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc., But Excluding Ashlar Faci. Submission Date for this Tender is 07-09-2022. Rolling Hardware Tenders in kapurthala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

33626982
Corrigendum : Provision Of Certain Sanctioned Work At Age B / R Beas Under Ge Kapurthala- 1 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc., But Excluding Ashlar Faci
Open Tender
Indian
Punjab
Kapurthala
07-09-2022

Tender Details

Provision Of Certain Sanctioned Work At Age B / R Beas Under Ge Kapurthala- 1 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc., But Excluding Ashlar Facings, Dressed Stonework And Precast Concrete Articles, Complete All As Specified And Directed By Engineer-In-Charge. 2 Taking Down Cement Or Cement Lime Plaster, Any Description On Brick Or Stone Walls, Etc Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And Directed By Engineer-In-Charge. 3 Taking Down Chowkats Or Frames With Shutters Not Exceeding 1.5 Sqm Each ( Without Taking Off Shutters From The Frames ) , Complete All As Specified And Directed By Engineer-In-Charge. 4 Taking Down Chowkats Or Frames With Shutters Exceeding 1.5 Sqm But Not Exceeding 4 Sqm Each ( Without Taking Off Shutters From The Frames ) . Complete All As Specified And Directed By Engineer-In-Charge. 5 Dismantling Taking Down Framed Trusses Of Span Not Exceeding 10M, Complete All As Specified And Directed By Engineer-In-Charge. 6 Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For, Complete All As Specified And Directed By Engineer-In-Charge. 7 Dismantling Asbestos Cement ( Corrugated, Semi-Corrugated, Etc. ) Sheets In Roof Coverings Including Ridges, Complete All As Specified And Directed By Engineer-In-Charge. 8 Dismantling Wall And Ceiling Boards ( Fibre, Pulp, Insulation, Etc. ) Or Insulation Boards / Slabs / Blankets, Any Thicknness, Including Cover Fillets, Complete All As Specified And Directed By Engineer-In-Charge. 9 Demolition Of Cement Concrete ( Unreinforced ) In Ground Floors And Pavings Not Exceeding 15Cm Thickness Below Or Above Ground Level Including Tiles, Terrazzo / Stones Etc. Complete All As Specified And Directed By Engineer-In-Charge. 10 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) , Removing Serviceable Tiles To Store And Rubbish Off The Premises, Complete All As Specified And Directed By Engineer-In-Charge. 11 M&L For Brickwork With Subclass ‘B’ Bricks, Straight Or Curved On Plan Exceeding 6M Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And Directed By Engineer-In-Charge. 12 -Ditto- All As Per Item No 11 Above But Except Bricks Etc. Complete All As Specified And Directed By Engineer-In-Charge. 13 M&L For Brickwork With Subclass ‘B’ Bricks, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cement Mortar 1:4. Complete All As Specified And Directed By Engineer-In-Charge. 14 M&L For Brick Work With Sub Class B Bricks Using Old Size Bricks Straight Or Curved On Plan To Any Radius In Half Brick Thick Wall Built In Cement Mortar 1:4. Complete All As Specified And Directed By Engineer-In-Charge. 15 M&L For Brick Work With Sub Class B Bricks Using Old Size Bricks Straight Or Curved On Plan Exceeding 6M Mean Radious Built In Cm1:6 Etc Complete All As Specified And Directed By Engineer-In-Charge. 16 M&L For Rendering 15Mm Thick On Fair Faces Of Brick Or Concrete Surfaces In Cement Mortar 1:6 On Walls, Finished Even And Smooth Without Using Extra Cement, Complete All As Specified And Directed By Engineer-In-Charge. 17 M&L For Rendering 15Mm Thick On Fair Faces Of Brick Or Concrete Surfaces In Cement Mortar 1:4 On Walls, Finished Even And Smooth Without Using Extra Cement, Complete All As Specified And Directed By Engineer-In-Charge. 18 M&L For 15Mm Thick Rendering In Cement Mortar 1:4 On Brick Or Concrete Surfaces With Liquid Water Proofing Compound, Finished Even And Smooth Without Using Extra Cement Etc Including Neeru Finish To Plastering Complete All As Specified And Directed By Engineer-In-Charge. ( Note : Water Proofing Compound Shall Be Measured And Paid Separately ) . 19 Supply Only Integral Water Proofing Compound Complete All As Specified And Directed By Engineer-In-Charge. 20 M&L For Preparation Of New Plastered Surfaces And Applying Two Coats Of Cement Base Paint Over And Including A Coat Of Chalk Whiting / Priming On Plastered Surfaces Of Walls, Complete All As Specified And Directed By Engineer-In-Charge. 21 M&L For Preparation Of New Plastered Surfaces And Distempering Walls With Two Coats Of Distemper Oil Emulsion, White Or Tinted Over And Including 1Mm Thick Wall Care Putty Including Primer, Complete All As Specified And Directed By Engineer-In-Charge. 22 M&L Preparation Of Newly Plastered Surfaces And Applying Two Coats Of White Wash Over A Coat Of Chalk Whiting / Priming On Plastered Surfaces Of Walls Etc. Complete All As Specified And Directed By Engineer-In-Charge. 23 M&L For Framed Work As In Doors Or Gates And Chowkhats Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings ( Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides ) And Hanging; Also Fastening Conforming To Gdefe 290 ( Gde E-165 ) . Complete All As Specified And Directed By Engineer-In-Charge. 24 S&F Rolled Sections Fe-410-W ( Gde E-250 ) Quality-A, As In Main And Cross Beams, Hip And Jack Rafters; Purlins Where Connectedto Common Rafters And Running Rails And Guides For Sliding Doors; Fixedwithangle Cleats Or Other Connecting Plates . Complete All As Specified And Directed By Engineer-In-Charge. 25 S&F Steel Work In Tubular Trusses Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240. Complete All As Specified And Directed By Engineer-In-Charge. 26 S&F Ms Pipes As In Vertical Posts, Fixed With Angle Cleats Or Other Connecting Plates, Rivets , Nut Bolts Etc, Complete All As Specified, Conforming Fe 410W ( Gde E-250 ) Quality B. Complete All As Specified And Directed By Engineer-In-Charge. 27 Erection And Fixing Only Steel Work In Tubular Trusses Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240. Complete All As Specified And Directed By Engineer-In-Charge. 28 Erection And Fixing Only Steel Tubular Work As In Purlins Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240. Complete All As Specified And Directed By Engineer-In-Charge. 29 S&F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws, Complete All As Specified And Directed By Engineer-In-Charge. 30 S&F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws, Complete All As Specified And Directed By Engineer-In-Charge. 31 S&F Wind Tie For Roof Including Securing Bolts: Flat Iron Fillets Including All Necessary Drilling, Bolting Or Riveting, Etc, And Similar Work Conforming To Fe 410-0 Or Fe 310-0 Etc. Complete All As Specified And Directed By Engineer-In-Charge. 32 S&F 2Nd Class Hard Wood 35Mm Thick Plain Framed, Panelled Shutter ( Two Panel ) With Lock Rail And Panel Of 9 Mm B.W.P. Commercial Ply Or 12 Mm Veneered Particle Board With Commercial Veneering On Both Faces. The Size Of Rail And Stile As Per Is : 1003 ( Part I ) , Kiln Seasoned And Chemically Pressure Treated, Complete All As Specified And Directed By Engineer-In-Charge. 33 S&F 2Nd Class Hw 35 Mm Thick Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauze, Etc. ( Without Sash Bars ) , Edges Of Framing Plain, Chamfered Or Rounded. Fitted With Cut And Mitred Beads For Securing Glass, Etc.; Sizes Of Me-Mbers Of Shutters As Specified In Ssr Part I, Section 8, Clause 8.24 ( A ) ; Supplied And Fitted To Chowkats Complete All As Specified And Directed. 34 S&F Steel Window 1.25Mm Thick Box Type ( Primer Coated ) Erw Hollow P Section Of Size 60Mm X 25Mm, 1.25 Thick Sheet Single Rebated Comprises Glazed Skelton Shutter Erw Sec 50Mm X 20Mm And 1Mm Thick With One Or Two Openable Leaf Consisting Two Nos Sash Bar Of T-Section 20Mm X 3Mm Complete Welded To Frame With One Vertical Mullion Of Erw Box Type T-Section Of Size 60Mm X 25Mm And 1.25Mm Thick Including Cutting Holes And Making Good Dismantled Portion In Pcc ( 1:2:4 ) Type B-1 Four Nos For Each Window Including Following Fitting Welded To Frame Shutter : ( A ) Hold Fast, 150Mm Long Of 12Mm Square Bar Made To Shape-04 Nos Per Window ( B ) Handles Ofz Section 100Mm Long ( C ) Stopper - 01 No Per Leaf ( D ) Cleat 55Mm Long Of Hollow Square 15Mm X 20Mm X 63Mm Welded To Hinges - 01 No Per Leaf ( E ) Ms Pintal Hinges Of Size 75Mm X 75Mm X 12Mm-02 Nos Per Leaf ( F ) Fabrication & Fixing Arrangement As Per Drg No Cejz / Td-7 / 07 Sheet 1 / 3 To 3 / 3.Note : Glass And Painting Shall Be Measured And Paid Separately Under Appropriate Item Etc Complete All As Specified And Directed. 35 S&F Steel Window 1.25Mm Thick Box Type ( Primer Coated ) Erw Hollow P Section Of Size 60Mm X 25Mm, Single Rebated Comprises Gauzed Skelton Shutter Erw Sec 50Mm X 20Mm And 1Mm Thick With One Or Two Openable Leaf Consisting Two Nos Sash Bar Of T-Section 20Mm X 3Mm Complete Welded To Frame With One Vertical Mullion Of Erw Box Type T-Section Of Size 60Mm X 25Mm And 1.25Mm Thick Including Cutting Holes And Making Good Dismantled Portion In Pcc ( 1:3:6 ) Type C-1 Four Nos For Each Window Including Following Fitting Welded To Frame Shutter : ( A ) Mild Steel Hold Fast, 150Mm Long Of 12Mm Square Bar Made To Shape-04 Nos Per Window ( B ) Handles Ofz Section 20Mm X 100Mm Long ( C ) Stopper - 01 No Per Leaf ( D ) Cleat 55Mm Long Of Hollow Square 15Mm X 20Mm X 63Mm Welded To Hinges - 01 No Per Leaf ( E ) Ms Pintal Hinges Of Size 75Mm X 75Mm X 12Mm-02 Nos Per Leaf ( F ) Grills Made Out Of Ms Square Bar 12Mm Dia Welded To Fi Frame Complete All As Specified And Shown On Drawings. Note : Wire Mesh And Painting Shall Be Measured And Paid Separately Under Appropriate Item Etc Complete All As Specified And Directed. 36 S&F Steel Ventilator1.25Mm Thick Box Type Fixed Type Prepared For Fixing Of Gauzed And Glass ( Primer Coated ) Erw Hollow P Section Of Size 60Mm X 25Mm Including Cutting Holes And Making Good Dismantled Portion In Pcc ( 1:3:6 ) Type C-1 Four Nos For Each Vent ) Including Following Fitting Welded To Frame Shutter: ( A ) Mild Steel Hold Fast, 150Mm Long Of 12Mm Square Bar Made To Shape – 04 Nos Per Vent ( B ) Handles Of Z Sec 20Mm X 100Mm Long ( C ) Stay ( D ) Cleat 55Mm Long Of Hollow Square 15Mm X 20Mmx63mm Welded To Hinges – 01 Noper Leaf ( E ) Mild Steel Pintal Hinges Of Size 75Mmx75mmx12mm-02 Nos ( F ) Grills Made Out Of Ms Square Bar 12Mm Dia Welded To Fi Frame Complete All As Specified And Shown On Drawings. Note: Wire Mesh / Glass Pane And Painting Shall Be Measured And Paid Separately Under Appropriate Item Etc. Complete All As Specified And Directed By Engineer-In-Charge. 37 S&F In Repairs Wire Netting Of Galvanised Steel Wire 1.40Mm Having Size Of Mesh 12Mm Dia Fixed With Tinned Tacks Of Wire Staples, Complete All As Specified And Directed By Engineer-In-Charge. 38 S&F 4Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square Not Exceeding 0.5 Sqm In Each Pane, Complete All As Specified And Directed By Engineer-In-Charge. 39 S&F 4Mm Thick Figured Glass, Pinhead Type In Squares Not Exceeding 0.5 Sqm Each Pane, Complete All As Specified And Direct By Engr-In-Charge. 40 S&F Galvanised Mild Steel Wire Cloth, 0.56Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18Mm, Complete All As Specified And Directed By Engineer-In-Charge. 41 S&F Powder Coated Of Any Colour Anodised Aluminium Window And Ventilator Shutters, Side Hung Type Without Sash Bars, Aluminium Sections Weighing 0.55 Kg / M Including Necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws, Anodised Aluminium Fittings Such As Peg Stays 150Mm Long ( 1 No. ) . Hinges Type B-21 100Mm Long ( 2 No. ) Suitable Handle ( 1 No. ) Etc. Complete All As Specified And Directed By Engineer-In-Charge. ( Thickness Or Powder Coating Should Not Be Less Than 50 Micron ) 42 S&F Solid Pvc Door Frame Of Size 50Mm X47mm Made Out Of 5Mm Wood Grain Printed Pvc Sheet Reinforced With M.S. Square Tube And Edges Will Be Painted To Match With Printed Sheets, Suppyling & Fixing In Opening As Per Specification & Drawing. Complete All As Specified And Directed By Engineer-In-Charge. 43 S&F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick ( Style ) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails. M.S. Frame Shall Be Covered With Heat Moulded Wood Grain Printed Pvc Sheet ‘C’ Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Wood Grain Printed Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; & 5Mm Thick X 15Mm Wide Pvc Sheet Beading Use Inside Stiles And Rails And Decorative Pvc Beading Of 10Mm X 10Mm ( 90 Degree ) Used.Panelling Of Wood Grain Printed Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing. Complete All As Specified And Directed By Engineer-In-Charge. 44 All As Per Item No.43 Above But Wire Gauzed I.E. Panel Will Be Of Wire Gauze In Lieu Of Wood Grain Printed Pvc Sheet Panel. The Wire Gauze Shall Be Wrapped On An Additional Square 8Mm M.S. Solid Tube And This Tube Shall Be Welded To M.S. Tubes. The Wire Gauge Shall Be Stretched To Tighten Firmly Complete All As Specified And Directed By Engineer-In-Charge. 45 S&F Anodised Aluminium Snap Grid Of Size 605 X 605Mm In Frame Work For False Ceiling. Complete All As Specified And Directed By Engineer-In-Charge. 46 Providing And Fixing Gypsum Board 8Mm Thick Of Size ( 600X600 ) Mm In Ceiling Fixed With Screw As Per Manufacturers Instructions. Complete All As Specified And Directed By Engineer-In-Charge. ( Frame Work For Ceiling Shall Be Measured And Paid Separately ) . 47 S&F Mild Steel Pressed Handles Of Size 150Mm, Oval Type, Stove Enamelled Black, Complete All As Specified And Directed By Engineer-In-Charge. 48 S&F Mild Steel Barrel Tower Bolts 200Mm Long, Stove Enamelled Black, With Bright Bolt And Fixed, Complete All As Specified And Directed By Engineer-In-Charge. 49 S&F Butt Hinges 100Mm Size, Medium Weight, Cold Rolled Mild Steel, And Fixed, Complete All As Specified And Directed By Engineer-In-Charge. 50 S&F Mild Steel Sliding Door Bolts 250Mm Long, Plate Type, Stove Enamelled Black, With Bright Bolt Not Less Than 12Mm Dia With And Including A Minimum Of 6 Bolts And Nuts, Four On Bolt Plate And Two On Staple Plate And Fixed, Complete All As Specified And Directed By Engineer-In-Charge. 51 S&F Mild Steel 300Mm, Ordinary Rat Tail Rod Pattern Springs Including Roller And Roller Plate Complete All As Specified And Directed By Engr-In-Charge. 52 S&F 100Mm Size Stainless Steel Butt Hinges, Medium Weight. Complete All As Specified And Directed By Engineer-In-Charge. 53 S&F Aluminium Alloy, Anodised, Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed, Length Of Bolt 250Mm. Complete All As Specified And Directed By Engineer-In-Charge. 54 S&F Aluminium Handles, Cast Type Anodised Of Size 125Mm Etc Complete All As Specified And Directed. 55 S&F 150Mm Long Aluminium Anodised, Barrel Tower Bolts Of Extruded Section And Fixed, Complete All As Specified And Directed By Engineer-In-Charge. 56 M&L For Preparation Of New Steel Surfaces Of Any Description, Over 10Cm In Width Or Girth, Not Otherwise Described And Applying Two Coats Of Synthetic Enamel Paint, Complete All As Specified And Directed By Engineer-In-Charge. 57 M&L For Preparation Of New Steel Surfaces Of Any Description, Over 10Cm In Width Or Girth, Not Otherwise Described And Applying Two Coats Of Synthetic Enamel Paint Over And Including A Coat Of Red Oxide Primer. Complete All As Specified And Directed By Engineer-In-Charge. 58 M&L For Preparation Of Old Steel Surfaces Of Any Description, Over 10Cm In Width Or Girth, Not Otherwise Described And Applying Two Coats Of Synthetic Enamel Paint, Complete All As Specified And Directed By Engineer-In-Charge. 59 M&L For Preparation Of New Wood Surfaces Of Any Description, Not Otherwise Described, Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over And Including A Coat Of Pink Primer, Complete All As Specified And Directed By Engineer-In-Charge. 60 M&L For 75Mm Thick Cement Concrete Type D-2, 1:4:8 Using 40Mm Graded Stone Aggregate As In Subbase Flooring, Complete All As Specified And Directed By Engineer-In-Charge. 61 M&L For 75Mm Thick Cement Concrete Type C-2, 1:3:6 Using 40Mm Graded Stone Aggregate As In Subbase Flooring, Complete All As Specified And Directed By Engineer-In-Charge. 62 M&L For Cement Concrete Type D2 1:4:8 ( 40Mm Graded Stone Aggregate ) As In Foundation, Filling And Mass Concrete. Complete All As Specified And Directed By Engineer-In-Charge. 63 M&L For Cement Concrete Type C-2, 1:3:6 ( 40Mm Graded Stone Aggregate ) As In Foundation, Filling And Mass Concrete. Complete All As Specified And Directed By Engineer-In-Charge. 64 M&L For 100Mm Thick Cement Concrete Type B-1, 1:2:4 ( 20Mm Graded Stone Aggregate ) As In Pavement / Hard-Standingfinished Even And Fair Without Using Extra Cement Including Necessary Form Work And To Divide The Area In Panels Complete All As Specified And Directed. 65 M&L For 40Mm Thick Pcc 1:2:4 Type B-1 With 20Mm Graded Stone Aggregate As In Flooring, Finished Even And Rough To Receive The Topping Layer. Complete All As Specified And Directed By Engineer-In-Charge. 66 M&L For 150Mm Thick Pcc 1:2:4 Type B-2 With 20Mm Graded Stone Aggregate As In Platform For Urinal, Finished Even And Rough To Receive The Topping Layer. Complete All As Specified And Directed By Engineer-In-Charge. 67 M&L For 75Mm Thick Cement Concrete Type C-2, 1:3:6 ( 40Mm Graded Stone Aggregate ) As In Plinth Protection Finished Even And Smooth ( Without Using Extra Cement ) . Complete All As Specified And Directed By Engineer-In-Charge. 68 M&L For Providing Cement Concrete 1:2:4 Type B-1 ( Using 20Mm Graded Stone Aggregate ) As In Roof Kerbs Or Mud Stops, Rounded Or Chamfered On Edges. Complete All As Specified And Directed By Engineer-In-Charge. 69 M&L For Joint Free Non - Skid Ceramic Colouredtiles 7 To 8 Mm Thick Square / Rectangular ) Laid Over 15Mm Thick Screed Bed In Cement Mortar 1:6, Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Complete All As Specified And Directed By Engr-In-Charge. 70 All As Per Item No 69 Above But As In Skirting In Cement Sand Mortar 1:4. Complete All As Specified And Directed By Engineer-In-Charge. 71 M&L For Coloured Glazed Ceramic Tiles In Vertical Surface 450Mm X 350Mm & 7Mm Thick Laid Over And Including 10Mm Thick Screed Bed In Cement Mortar 1:4, Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match, Complete All As Specified And Directed By Engineer-In-Charge. 72 M&L For Joint Free Non-Skid Ceramic Coloured Tiles 7 To8 Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.18 Sqm But Not Exceeding 0.38 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15Mm Thick Screed Bed In Cement Mortar 1:6. Complete All As Specified And Directed By Engineer-In-Charge. 73 M&L For Machine Cut Kota Stone Slab Flooring 20-25Mm Thick Over And Including 20Mm Thick Cement Screed Base In Cement Mortar 1:6, Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing, Treating The Surface With Bees Wax Polish, Complete All As Specified And Directed By Engineer-In-Charge. 74 M&L For Kota Stone Slab 20-25Mm Thick In Riser Of Steps, Skirtings, Dado And Pillar, Laid Over And Including 15Mm Thick Cement Screed In Cement Mortar 1:4 And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing, Treating The Surface With Bees Wax Polish, Complete All As Specified And Directed By Engineer-In-Charge. 75 M&L Hardcore Of Broken Bricks Ofgauge Not Exceeding 63 Mm, Deposited, Spread And Levelled In Layers Not Exceeding 15 Cm Thick, Watered And Rammed To A True Surface. Complete All As Specified And Directed By Engineer-In-Charge. 76 M&L For Sand Filling Under Floors Or In Foundations Including Watering And Consolidation, Complete All As Specified And Directed By Engineer-In-Charge. 77 M&Lfor Providing Reinforced Cement Concrete Cast In Situ Type B-1, 1:2:4 ( 20 Mm Graded Stone Aggregate ) As In Lintels Upto 1.5M Clear Span Including Necessary Formwork Complete All As Specified And Directed By Engr In Charge. ( Note : Reinforcement Shall Be Measured And Paid Separately ) 78 M&L For Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips Quality Conforming To. Complete All As Specified And Directed By Engineer-In-Charge. 79 -Ditto- All As Per Item No 78 Above But 5Mm Dia And Over Upto And Including 10Mm Dia In Stirrups, Spaces And Binders. Complete All As Specified And Directed By Engineer-In-Charge. 80 M&L For Reinforced Cement Concrete ( Nominal Mix ) Type B-1 1:2:4 ( 20Mm Graded Stone Aggregate ) As In Chajjas, Complete All As Specified And Directed By Engineer-In-Charge. 81 Use And Waste For Formwork To Chullah Hoods, Chajjas, Troughs And Similar Items Including Edges, Complete All As Specified And Directed By Engineer-In-Charge. 82 M&L For Reinforced Cement Concrete ( Nominal Mix ) Type B-1 1:2:4 ( 20Mm Graded Stone Aggregate ) As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like, Complete All As Specified And Directed By Engineer-In-Charge. 83 Use And Waste Formwork To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work; Not Exceeding 200Mm Thick ( Horizontal / Sloping ) , Fair Finished Surfaces Concrete Flat, Complete All As Specified And Directed By Engineer-In-Charge. 84 Use And Waste Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors, Window Cills, Concrete Railings, Openings In Concrete Walls, Floors And Roofs Exceeding 10Cm But Not Exceeding 20Cm Wide And Sides Of Rcc / Pcc Bands In Walls, Horizontal Or Sloping, And Similar Work For Rough Finished Surface Of Concrete, Complete All As Specified And Directed By Engineer-In-Charge. 85 M&L For 20Mm Thick Granite ( Of Any Type ) Work ( Table Rubbed And Polished ) In Steps, Jambs, Pillars, Window-Cills, Cooking Platforms And Like Over And Including Cement Mortar ( 1:4 ) Including Pointing In White Cement ( 1:2 ) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite, Complete All As Specified And Directed By Engineer-In-Charge. 86 M&L For Rounding To Edges Of Stone Slabs One Edge, Such As In Steps, Cooking Platform, And Other Similar Situations, Complete All As Specified And Directed By Engineer-In-Charge. 87 M&Lpcc1:2:4 Type B-1 ( 20 Mm Graded Stone Aggregate ) As In Bed Blocks, Coping, Etc. Complete All As Specified And Directed By Engineer-In-Charge. 88 S&F Rotational Moulded Polyethylene Water Storage Tanks 1000 Ltr Capacity ( Three Layered ) ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position All As Specified Including 20Mm Dia Ball Brass Valve, Complete All As Specified And Directed By Engineer-In-Charge. 89 S&Fvitreous China Wash Basin, White, Flat Back, Size 550X400mm Including Brackets, Cutting For And Pinning In Ends Of Brackets Or Eracting Stand & Waste Pipe, Coupling Etc As In Repairs Complete All As Specified And Directed. 90 S&F Gun-Metal, Globe Or Gate Valves, With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixed To Steel Pipe Orunion, 20Mm Bore Dia Of Pipe. Complete All As Specified And Directed By Engineer-In-Charge. 91 S&F In Repairs, Cp Waste Coupling, Bore Dia Of Discharge Pipe 32Mm. Complete All As Specified And Directed By Engineer-In-Charge. 92 Supply And Fixing 15Mm Dia Pillar Taps, Cast Copper Alloy With Capstan Heads Chromium Plated, Screwed Down High Pressure, With Or Without Lettered With Long Screwed Shanks And Fly-Nuts, Screwed For Iron Pipe But Fancy Type And Fixed Etc. Complete All As Specified And Directed By Engineer-In-Charge. 93 S&Fvitreous China Under Counter Top Wash Basin, Snow White, Oval Type Of Size 560Mm X 470Mm X 190Mm Including Brackets, Cutting For And Pinning In Ends Of Brackets Or Eracting Stand & Waste Pipe, Coupling Etc. Complete All As Specified And Directed By Engineer-In-Charge. 94 S&F Vitreous China Urinal, Half Stall Type, White, Complete Including Providing And Fixing Plugs, Bedding Urinal Against Wall In Cement Mortar 1:2, Securing Urinal To Plugs With And Including 60Mm Long Brass Screws, Pointing Around Urinal Back In Cement; Fixing Automatic Flushing Cistern With Brackets, Flush Pipe, Grating And Union For Discharge Pipe. Complete All As Specified And Directed By Engineer-In-Charge. 95 S&F Urinal Spreader Of Cp Any Colour For Fixing With 15 Mm Dia Pipe. Complete All As Specified And Directed. 96 S&F Pvc Waste Pipe For Wash Basin, Urinal Etc. Complete All As Specified And Directed By Engineer-In-Charge. 97 S&F 20Mm Thick Makrana White Marble Slab, Machine Cut, Bedded Jointed And Pointed With Grey Cement Slurry Including Cutting And Polishing, Rounding To Edges Of Stone Slabs, Fixed In Walls As In Urinal Partition, Complete All As Specified And Directed By Engr-In-Charge. 98 S&F15 Mm Dia Fancy Type Chromium Plated Angle Stop Valve Of Any Colour Pressure Screwed For Iron Pipe And Fixed. Complete All As Specified And Directed By Engineer-In-Charge.Make : Cera, Jaguar, Hindware. 99 S&F Cp Waste Coupling Suitable For Urinals, Bore Dia Of Discharge Pipe 32Mm. Complete All As Specified And Directed By Engineer-In-Charge. 100 S&F Vitreous China Squatting Pan ( Orissa Pattern ) , Size 580 X 440Mm White, With Integral Foot Rests ( Excluding Flushing Cistern And Flush Pipe ) Complete Including Provision Of Lime Concrete Bedding. Complete All As Specified And Directed By Engineer-In-Charge. 101 S&F Vitreous China Wash Down Water Closet Pan ( Pedestal Pattern ) , White ( Excluding Fixing Bolts, Flushing Cistern And Flush Pipe ) Complete Including Plastic Water Closet Seat, Black, Closed Pattern With Flat Bottom, And Cover And Mild Steel Chromium Plated Or Aluminised Hinging Devices With Recessed Bottom, Jet Spray, Etc. Complete All As Specified And Directed By Engineer-In-Charge. 102 S&Flow Level Flushing Cistern Pvc Valveless Syphonic Action Type, 10 Ltrs Capacity Including Supply Pipe & Fixing Brackets Of M.S. Angle Of Size ( 25Mmx25mmx3mm ) , 30 Cm Long In Pcc ( 1:2:4 ) Type B-1, Block Of Size ( 10Cmx10cmx10cm ) On Walls, Etc. Complete All As Specified And Directed By Engineer-In-Charge. 103 S&F Grating Doom 100Mm Dia With Waste Hole Ofcp. Complete All As Specified And Directed By Engineer-In-Charge. 104 S&F 15Mm Dia Fancy Type Long Body Pillar Taps, Cast Copper Alloy With Capstan Heads Chromium Plated, Screwed Down High Pressure, With Or Without Lettered With Long Screwed Shanks And Fly-Nuts, Screwed For Iron Pipe But Fancy Type Etc. Complete All As Specified And Directed By Engineer-In-Charge. 105 S&F Towel Rail 600Mm Long Of Stainless Steel Fixed With And Including Chromium Plated Brassscrews And Or Cleats. Complete All As Specified And Directed By Engineer-In-Charge. 106 S&F1800mm X 1200Mm And 6Mm Thick Bevelled Edge Mirror Of Selected Quality Glass, Complete Fixing Including Stainless Steel Spacers, Mount Stand Bolt Screws Etc. Complete All As Specified And Directed By Engineer-In-Charge. 107 S&F Cp Soap Dish, Any Type, Fixed To Plugs With Chromium Plated Brass Screws. Complete All As Specified And Directed By Engineer-In-Charge. 108 S&F 15Mm Dia Chromium Plated Fancy Type Bib Tap Cast Copper Alloy With Crutch Or Butter Fly Handle Screwed Down Screwed For Iron Pipe And Fixed To 15Mm Bore Pipe Fixed. Complete All As Specified And Directed By Engineer-In-Charge. 109 S&F Pvc Connection 15Mm Size With Ptmt Nuts Of Length 450Mm Etc. Complete All As Specified And Directed By Engineer-In-Charge. 110 S&F Pvc ( Swr ) P Trap 110Mm Bore. Complete All As Specified And Directed By Engineer-In-Charge. 111 S&F 110Mm Bore Pvc ( Swr ) Wc Connector With Lip Ring. Complete All As Specified And Directed By Engineer-In-Charge. 112 S&F 110Mm Bore Pvc ( Swr ) Junction Single, ( Single T ) Equal Or Unequal. Complete All As Specified And Directed By Engineer-In-Charge. 113 S&F 110Mm Bore Pvc ( Swr ) Bends Any Radius. Complete All As Specified And Directed By Engineer-In-Charge. 114 S&F 110Mm Bore Pvc ( Swr ) Pipe Single Socketed, In Any Length With Rubber Ring Joints, Laid In Trenches Or In Floors. Complete All As Specified And Directed By Engineer-In-Charge. 115 S&F 75Mm Bore Pvc ( Swr ) Pipe Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls As A Vent Pipe. Complete All As Specified And Directed By Engineer-In-Charge. 116 S&F 75Mm Bore Pvc ( Swr ) Pipe Single Socketed, In Any Length With Rubber Ring Joints, Laid In Trenches Or In Floors. Complete All As Specified And Directed By Engineer-In-Charge. 117 S&F 75Mm Bore Pvc ( Swr ) Bends Any Radius. Complete All As Specified And Directed By Engineer-In-Charge. 118 Cutting Chases, Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Not Exceeding 20 Cm Girth. Complete All As Specified And Directed By Engineer-In-Charge. 119 S&F 75 Mm Bore Pvc ( Swr ) Vent Cowl, Complete All As Specified And Directed By Engineer-In-Charge. 120 S&F Steel Tubes Medium Grade Bore Of Tube In 15Mm Galavanised With All Fitting Laid In Trenches, Walls, Ceiling Or Laid In Floors Etc. Complete All As Specified And Directed By Engineer-In-Charge. 121 All As Per Item No 120 Above But Of Size Of 20Mm Bore. Complete All As Specified And Directed By Engineer-In-Charge. 122 M&L For Chequered Cement Concrete Tiles 20Cm X 20Cm X 25Mm Thick Over And Including 20Mm Thick Screed Bed Of Cement Sand Mortar 1:4 , Set, Jointed And Pointed In Neat Cement Slurry In Floors / Path With Grey Cement And Pigment To Match. Complete All As Specified And Directed By Engineer-In-Charge. 123 Excavation In Post Holes ( Or Similar Holes ) Each Not Exceeding 0.50 Cum, And Getteing Out, Returning Filing In And Ramming Earth With Broken Rubble Mixed With Earth Around In Layers Not Exceeding 25Cm, Watering Etc And Removing Surplus Soil Not Exceeding 50M And Making Good Surface In Loose / Soft Soil, Complete All As Specified And Directed By Engineer-In-Charge. 124 Surface Excavation Not Exceeding30cm Deep And Averaging 15Cm Deep And Getting Out In Soft / Loose Soil. Complete All As Specified And Directed By Engineer-In-Charge. 125 Excavating In Trenches In Any Type Of Soilnot Exceeding 1.5M Wide And Not Exceeding 1.5 M Depth For Foundation & Getting Out, Complete All As Specified And Directed By Engineer-In-Charge. 126 Excavating Over Areas, Not Exceeding 1.5M Deep And Getting Out; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. And Getting Out, Complete All As Specified And Directed By Engineer-In-Charge. 127 Excavating Over Areas, Of Depth Exceeding 1.5M But Not Exceeding 3 M And Getting Out; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. And Getting Out, Complete All As Specified And Directed By Engineer-In-Charge. 128 M&L For Filling Good Earth Including Spreading, Leveling, Watering And Well Ramming In Layers Not Exceeding25cm For Soft / Loose Soil, Complete All As Specified And Directed By Engineer-In-Charge. 129 Returning Filling Including Spreading, Leveling, Watering And Well Ramming In Layers Not Exceeding25cm For Soft / Loose Soil, Complete All As Specified And Directed By Engineer-In-Charge. 130 Removing Excavated Materials ( Soil ) To A Distance Not Exceeding 50M And Depositing Where Directed Of A Level Not Exceeding 1.5M Above The Starting Point. Complete All As Specified And Directed By Engineer-In-Charge. 131 Supply & Lay 200Mm Bore Reinforced Concrete Pipes, Class Np3, Laid And Jointed Complete With Collars, Complete All As Specified And Directed By Engineer-In-Charge. 132 M&L For Cement Concrete 1:3:6 Type C-2 Using 40Mm Graded Stone Aggregate As In Concrete Bed To Drain Pipes For Bore Dia Of 200Mm Including Packing Under, And Haunching Against The Sides Of Pipes After They Are Laid And Tested; In, Complete All As Specified And Directed By Engineer-In-Charge. 133 M&L For Cement Concrete Type B-1, 1:2:4 ( 12.5Mm Graded Stone Aggregate As In Surface Channels And Drains, Complete All As Specified And Directed By Engr-In-Charge. 134 M&L For 75Mm Thick Pcc 1:2:4 Type B-1 With 20Mm Graded Stone Aggregate As In Flooring, Finished Even And Rough To Receive The Topping Layer. Complete All As Specified And Directed By Engineer-In-Charge. 135 Extra For Forming Fair Finished Drain Or Channel Not Exceeding 45 Cm Inner Girth In Cement Concrete, Using Extracement, Including Forms, Moulds, Mitred / Stopped Ends Etc. 136 M&L For Precast Cement Concrete Type B-1, 1:2:4 As In Cover Slabs Over Drain / Manholes Etc. Including Necessary Formwork, Complete All As Specified And Directed By Engr-In-Charge. 137 M&L For Construction Of Sokage Well With Excavation, In Any Type Of Soil, Foundation In Pcc 1:3:6, Wells Of Honeycombed Masonary With Top Ring Of M-25 Concrete, Including Intercepting Chamber And Screen Chamber Brick Work In Cm, Rcc Cover Slabin M-25 / Sfrc Cover, Interconnecting Pipe Of Rcc / Dwc Complete Filled With Brick Bats, Complete Of Size 2.4M Dia X 3M Effective Depth. Complete All As Specified And Directed By Engineer-In-Charge. 138 Taking Down Carefully Aluminium Point Wiring On Casing Caping / Through Conduit ( Light Fan, Socket Or Power ) Complete With Fittings Such As Switches, Ceiling Roses, Pendants, Regulators, Box Type Tube Light Fittings, Removing The Materials From Site Except Fittings Etc Which Shall Be Reused In The Work And Making Good The Disturbed Surfaces Of Walls / Ceiling / Floors Etc Complete All As Specified And As Directed By Engineer-In-Charge 139 M & L For Point Wiring For One Light Or One Fan Point Controlled By One Switch Or With One Switch And Regulator With Pvc Unsheathed Single Core Multistranded Copper Conductor ( Frls ) Cable Of Size 1.5 Sqmm ( Nominal Area ) In And Includingpvc Conduit 20 Mm Bore By Cutting Chases In Wall By Cutter And Making Good The Surface In Cm 1:3 And To The Original Specification And Cast Iron / Pressed Steel Concealed Terminal Boxes Includingproviding3mm Thick Plastic Laminated Sheet Cover ( Hylem ) Including One Run Of Pvc Insulated Copper Conductor ( Frls ) Cable Of Size 1.5 Sqmm With Green Insulation As Earth Wire And Connected To Earth Dolly Complete All As Specified. ( Switch / Socket Outlet To Be Measured & Paid For Separately ) . 140 All As Per Srl Item No 139 Here In Before But For 3 Pin Socket Outlet 5 Amps On Same Board . 141 All As Per Ser Item 139 Abovebut For 3 Pin Socket Out Let 5 Amps On Independent Board 142 All As Per Srl Item No 139 Here In Before But For 3 Pin Socket Outlet 15 Amps On Independent Board With Pvc Unsheathedcopper Conductor Cable Of Size 2.50 Sqmm Including Copper Earth Wire Of Size 1.50 Sqmm And Connected To Common Earth Dolly Complete All As Specified. ( Switch / Socket To Be Measured & Paid For Separately ) 143 Supply And Fixing In Replacement Sub Main Wiring With Two Single Core Frls Insulated Cable With Copper Conductor Stranded And Sheathed Of Size 6 Sq Mm In And Including Pvc Conduit Including 1 X 6 Sq Mm Frls Copper Earth Wire To Common Earth And Connected To Earth Dolly Complete All As Specified And Directed. 144 Supply & Fixing Switch Piano Flushtype 5 Amp Single Pole One Way. 145 Supply & Fixing Switch Piano Flushtype 15 Amp Single Pole One Way. 146 Supply & Fixing Socket Outlet 5 Pin 5 Amps Flush Type Multipurpose. 147 Supply & Fixing Socket Outlet Multipurpose 2 In One, 3 Pin 5 / 15Amps Flush Type. 148 Supply & Fixing Ceiling Rose Surface Bakelite 65 X 50Mmthree Terminal Complete All As Specified And As Directed By Engineer-In-Charge. 149 Supply & Fixing Fan Regulator Electronic Step Type And Making Connections. 150 Supply & Fixing Angular Lamp Holder Insulated Body With Back Plate Suitable For Batten Fittings Including 1 X 9 W Led Lamp. 151 S & F Surface Mounting Energy Saving Led Tube Light Fitting, 1X20w, 230V , High Efficiency Pmma Diffuser Gives Soft Glare Free Light With Led Tube Rode 20 W ( White ) Complete With All Accessories. 152 Supply And Fixing Led Light Fitting Mirror Type With High Out Put Diffuser 2 Feet, 10 Watt 220 V Ac Decorative Type With Driver Holder And Led Lamp Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete. 153 Supply & Fix In Replacement Ofceiling Fan 1200 Mm Sweep, 240 Volts Colour- Opal White Make- Crompton Model Cool Breez Or Equivalent In Bajaj / Havells / Orient, And Connecting Up Including Provision Of Flexible Copper Conductor Cable From Ceiling Rose / Connector To Fan And Gi Pipe / Steel Rod, Nuts, Bolts, Clamps Etc As Required At Siteall As Specified And Directed By Engr-In-Charge. 154 Supply & Fixexhaust Fans Ac Single Phase 230 / 240 V Of Size 450 Mm Sweep Hevy Duty With Louver ( Metal Body ) Including Necessarycutting Of Wall In Sutiable Dia For The Fixing Of Exhaust Fan And Make It In Good Finish With Plaster Work Completeas Specified And Directed. 155 Supply & Fixexhaust Fans Ac Single Phase 230 / 240 V Of Size 300 Mm Sweep With Louver ( Metal Body ) Including Necessarycutting Of Wall In Sutiable Dia For The Fixing Of Exhaust Fan And Make It In Good Finish With Plaster Work Completeas Specified And Directed. 156 Supply And Fix Water Heater Storage Type, Electric, Capacity 50 Litres.Bee 5 Star Rated. 157 Supply And Fixingpvc Connection Cold Water Pipe 18 Long, 15Mmdia With Brass Jem Nut And Wahser, Both Side Complete All As Specified And Directed By Engineer-In-Charge. 158 All As Per Ser Item No 157 Here In Before But Hot Water Pipe Made Of Chromium Plated Brass Flexible Tubing. 159 Supply And Fixing Stop Cock Brass Of Size 15 Mm Dia. 160 Supply And Fixing Bib Cock Brass Of Size 15 Mm Dia. 161 Supply And Fixing Mcbsingle Pole 6 To 32 Amps 240 Volts. 162 Supply And Fixing Mcb 40 Amp Spn 240 Volt, Complete. 163 Supply And Fixing Mcb 63 Amp Tpn 415 Volt, Complete. 164 Supply & Fixing Sheet Metal Enclosures With Double Door, Detachable Gland Plates Flush / Mounting For Mcb’S Fitted With Bus Bar, Earth Wire And Neutral Link, Spn12 Ways, 240 Volts. 165 S&Ftpn4 Way, Vertical Type Distribution Box ( Vtpn Db ) In Double Door, Ip -54, Suitable Forflush Mounting And Surface Mounting With 250 A Copper Bus Barfor Each Ph , Two Neutral Bar, Two Earthbarwith Provn For Mccb 100 Aas Incomer ( W / O Mccbs ) Andsp / Tp As Out Going Complete. 166 Supply And Fixing Mccb 100 Amp 4P 415 Volt, Complete. 167 M & L Ofearthing Complete With Galvanized Steel Earth Plate Trode 60Cm X 60Cm X 6Mm Thick Buried Directly In Ground Vertically In A Pit Not Less Than 2.25 Meter Below Ground Level With Top Edge Of Earth Plate At A Depth Not Less Than 1.5 Meter Below Level Connected To Gi Earth Wire 4Mm Diaby Means Of Bolts, Nuts And Washers ( Earth Plate Covered With Charcoal Dust And Common Salt In Alternate Layers ) Gi Earth Wireprotected By Galvanized Steel Pipe Light Grade Of 15 Mm Dia Upto Switch Board And Connected To Main Switch Board, Including Provision Of 20Mm Dia Gi Tubing Light Grade Watering Pipe With Funnel And Wire Mesh Pcc Earth Pit ( 1:3:6 ) Type C-1 Covered With Ci Cover Hinged With Frame Including Excavation And Earth Work Complete All As Specified And Shown In Electrical Plate No 5 Of Ssr Part I Including Testing On Completion. 168 Disconnecting And Taking Out Old U / S Cable Of Service Connection / Sub Main Of Any Size And Type From Pole To DbS / Main Switch Complete All As Specified 169 Excavation In Trenches In Soft / Loose Soil Not Exceeding 1.50 Mtr Wide And Not Exceeding 1.50 Mtr In Depth For Ltaking Out Old Cable / Laying Of Under Ground Cable / Foundation Of Poles / Stays Including Segregation Of Old Serviceable Bricks Complete All As Specifiedand Directed By Engineer-In-Charge. 170 M & L For Brick Protection Using Old Size Sub Class B Bricks, Laid Flat Dry But Adjoining To Each Other Laid Lengh Wise Perpendicular To The Axis Of Cable Complete All As Specified And Directed. 171 Supplying, Filling In Trenches Spreading, Leveling Sand Cushioning 8 Cm Below And 15 Cm Above The Cable For Under Ground Cable Complete All As Specified & Directed. 172 Supply, Laying And Testing Cable Xlpe Insulated , Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 16 Sq Mm 2 Core. 173 Supply, Laying And Testing Cable Xlpe Insulated , Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 35 Sq Mm 3.5 Core. 174 Supply And Fixing Led Bldg Security Light Fitting 20 Watt Powder Coated Pressure Die Cast Aluminium Compact Led Security Light Including1.5 Mtr Long 40 Mm Bore Gi Pipe Mounting Bracket Made To Shape For Fixing On Wall With 40 Mm X 6 Mm Flat Iron Clamp 02 Numbers With 16 Mm Dia Bolts, Nuts And Washersall As Specified And Directed By Engineer-In-Charge.Make- Crompton, Product Code -Lsts-20-Cdl-M Or Equivalent In Bajaj / Philips / Polycab / Havells: Contractor Shall Provide 1 Years Written Manufactures Warranty For The Led Fixture Complete Including Driver From The Certified Date Of Completion. 175 M / L For Gi Pipe Light Grade Galvanized With All Fitting Laid In Trenches / On Pole / Road Crossing Of Size 40Mm 176 M / L For Gi Pipe Light Grade Galvanized With All Fitting Laid In Trenches / On Pole / Road Crossing Of Size 50Mm 177 Cutting The Existing 40 / 50Mm Dia Gi / Ci Pipe Line For Insertion And With Suitable Tee And Jointing Material Includingexcavation And Earth Works All Are Specified And Directed By Engr- In- Charge 178 Supply And Laying In Trenches Orfixingto Wall And Ceilingpipe Galvanised Medium Grade 25Mm Bore Including Fittings Complete Allas Specifieddirected By Engr In Charge. 179 Supply And Laying In Trenches Orfixingto Wall And Ceilingpipe Galvanised Medium Grade 25Mm Bore Including Fittings Complete Allas Specifieddirected By Engr In Charge. 180 Supply And Fixing Gate Valve Flangedcomplete Of Size 25 Mm Dia 181 Supply And Fixing Ball Brass Valves, High Pressure, With Polythene Float And Nut Complete Size 25Mm Bore.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-08-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 88380.0 /-
Tender Value
INR 44.19 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail