Supply, Installation, Testing And Commissioning Of Central Heating System At Sub District Hospital Sogam-2 Hot Water Generator 3 Hot Water, Horizontal Water Tube Boilers Complete With Water Coils, Combustion Equipments, Control Panel, Controls, , jammu-Jammu And Kashmir

Public Works Department has published Supply, Installation, Testing And Commissioning Of Central Heating System At Sub District Hospital Sogam-2 Hot Water Generator 3 Hot Water, Horizontal Water Tube Boilers Complete With Water Coils, Combustion Equipments, Control Panel, Controls, . Submission Date for this Tender is 06-10-2022. Tanks and Cylinders Tenders in jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

33591680
Corrigendum : Supply, Installation, Testing And Commissioning Of Central Heating System At Sub District Hospital Sogam-2 Hot Water Generator 3 Hot Water, Horizontal Water Tube Boilers Complete With Water Coils, Combustion Equipments, Control Panel, Controls,
Open Tender
Indian
Jammu And Kashmir
Jammu
06-10-2022

Tender Details

Supply, Installation, Testing And Commissioning Of Central Heating System At Sub District Hospital Sogam-2 Hot Water Generator 3 Hot Water, Horizontal Water Tube Boilers Complete With Water Coils, Combustion Equipments, Control Panel, Controls, Accessories And 5 Hp Mono Block Pump Set Alongwithfoundation As Per Oem 4 Capacity Each 4, 00, 000 Kcal / Hr 5 Boiler Chimeny 6 Chimney For 4, 00, 000 Kcal Boiler 300 Mm Dia, With 200 Mm Dia Flu Gas Duct Extrenaly Mounted Support Raising At 12M Above The Ground Level. 7 Hot Water Circulation Pumps 8 Hot Water Circulation Monoblock Pump Complete With Electric Motor Of 10 Hp Rating Alongwithcommon Base Frame Duly Grouted In Cement Concrete Foundation. 9 Capacity 1000 Lpm At 25 M Head 10 Oil Transfer Pumps 11 Gear Oil Transfer Pump With Electric Motor Of 3 Hp Rating Alongwithcommon Base Frame Duly Grouted In Cement Concrete Foundation.Capacity 50Lpm 12 Softwater Pumps 13 Soft Water Pumpcomplete With Electric Motor Of 1 Hp Rating Alongwithcommon Base Frame Duly Grouted In Cement Concrete Foundation.Capacity 50 Lpm At 15 M Head 14 Mixing Tank 15 Hot Water Mixing Tank Made Of 8 Mm M.S. Plate With Dished Ends, Manhole Dully Covered And Necessary Connections Covered With 50 Mm Glass Wool Insulation And Finished With 24 Gauge Aluminium Cladding And Complete As Per Specifications And Drawingwith Structural Support To Raise The Tank At Least 300 Mm Above Finish Fl. 16 3500 Litres, Size 1.3 M Dia X 2.65 M Long. 17 Bulk Oiltank 18 Bulk Oil Tank 20Klcomplete Of 6 / 8 Mm Ms Plate With Manhole Dully Covered To Be Laid Underground With Allied Civil Works As Per Specifications And Drawings 19 20000 Litres, Size 2.1 M Dia X 6 M Long. 20 Day Oiltank 21 Day Oil Tank Of 4 Mm M.S Plate Complete With Manhole Dully Covered, Gauge Glass 3 Kw Oilheater, Necessary Connections And Strucrural Support For Mounting Oil Tank And Ladder Made Out Of Tubular Ms Section Complete As Per Specifications And Drawing. 22 Capacity990 Litres, Each Size 1 M X 1 M X 1 M 23 Expansion Tank 24 Hot Water Expansion Tank Of 4 Mm M.S Complete With Manhole Dully Covered, Necessary Connections Covered With 50 Mm Glass Wool Insulation And Finished With 24 Gauge Aluminium Cladding And Strucrural Support For Mounting Expansion Tank With Insulation And Cladding. 25 Capacity 500 Litres, Each Size 0.8M X 0.8M X 0.8M 26 Soft Water Tank 27 Soft Water Tank Of Hdpe ( Tripple Layer ) With Necessary Connectionscapacity 1000 Litres 28 Water Softner Plant 29 Water Softening Plant Havingsteel Body With Accessories Viz Softner Pump, Valve, Requisite Brine Tank Etc. Complete In All Respect Alongwith Cement Concrete Foundation. Capacity 1500 Litres / Hr 30 Hot Water Radiators 31 Steel Panel Heating Radiators With Working Pressure Ranging From 10-13 Bar Having Working Temperature At 110 C , Complete With Top Grilles And Side Covers As Standard Alongwith Inlet Valve, Outlet Valve, Air Purge Valve And Threaded Plug As Per Oem Inlet Water Temp: 75ºcoutlet Water Temp: 65ºcroom Temp: 22 ºc 32 1500 Kcal / Hr ( Double Panel Double Radiators ) 33 2000 Kcal / Hr ( Double Panel Double Radiators ) 34 2500 Kcal / Hr ( Double Panel Double Radiators ) 35 3000 Kcal / Hr ( Double Panel Double Radiators ) 36 3500 Kcal / Hr ( Tripple Panel Tripple Radiators ) 37 4000 Kcal / Hr ( Tripple Panel Tripple Radiators ) 38 4500 Kcal / Hr ( Tripple Panel Tripple Radiators ) 39 Fan Coil Units 40 Hydronic Hi-Wall Units Complete With Inlet Outlet / Outlet Valves, Y-Strainer And Copper Piping And Fittings Etc.Inlet Water Temp: 75 Ocoutlet Water Temp: 65 Ocroom Temp: 22 Oc 41 3000 Kcal / Hr 42 M.S. Piping ( Hot Water ) Above Ground 43 Mildsteel Erw Hot Water Piping Of Class ‘C’ Complete With Fittings Etc As Per Specifications Anddrawings. 44 150 Mm Dia 45 125 Mm Dia 46 100 Mm Dia 47 80 Mm Dia 48 65 Mm Dia 49 50 Mm Dia 50 40 Mm Dia 51 32 Mm Dia 52 25 Mm Dia 53 20 Mm Dia 54 M.S. Piping ( Hot Water ) Under Ground 55 Mildsteel Erw Hot Water Piping Of Class ‘C’ Complete With Fittings Etc To Be Laid Underground In Trenches At A Depth Of 450 Mm Below Ground Level On Cement Concrete Blocks At A Distance Of 3 M As Per Specifications. 56 125 Mm Dia 57 25 Mm Dia 58 M.S. Piping ( Galvanised ) 59 Mildsteel Erw ( Galvanised ) Water Piping Of Class ‘B’ Complete With Fittings Etc As Per Specifications Anddrawings. 60 25 Mm Dia 61 20 Mm Dia 62 Angle Iron Supports 63 Supports For Hot Water Piping At Various Locations To Be Fabricated Out Of 4040X5 Mm, 5050X5 Mm, 6565X5 Mm As Per Site Requirement. 64 Pipe Insulation ( Hot Water ) Above Ground 65 Glass Wool Pipe Section 80 Kg / M3 Density Insulationalong With Chicken Mesh And Alluminium Cladding Of 24 Gauge As Per Specifications. 66 150 Mm Dia ( 50 Mm Thick Insulation ) 67 125 Mm Dia ( 50 Mm Thick Insulation ) 68 100 Mm Dia ( 50 Mm Thick Insulation ) 69 80 Mm Dia ( 50 Mm Thick Insulation ) 70 65 Mm Dia ( 40 Mm Thick Insulation ) 71 50 Mm Dia ( 40 Mm Thick Insulation ) 72 40 Mm Dia ( 25 Mm Thick Insulation ) 73 32 Mm Dia ( 25 Mm Thick Insulation ) 74 25 Mm Dia ( 25 Mm Thick Insulation ) 75 20 Mm Dia ( 25 Mm Thick Insulation ) 76 Pipe Insulation ( Hot Water ) Under Ground 77 Glass Wool Pipe Section 80 Kg / M3 Density Insulationalong With Chicken Mesh, Frp Tissue And Tarfelt As Per Specifications 78 125 Mm Dia ( 50 Mm Thick Insulation ) 79 25 Mm Dia ( 25 Mm Thick Insulation ) 80 Butterfly Valve 81 125 Mm Dia 82 100 Mm Dia 83 80 Mm Dia 84 50 Mm Dia 85 Ball Valve 86 25 Mm Dia 87 20 Mm Dia 88 15 Mm Dia 89 Y-Strainers 90 C.I. / G.M. Y Strainer With Flanges Etc. Complete As Per Specification Of The Following Sizes. 91 100 Mm Dia ( C.I. Flanged ) 92 25 Mm Dia ( Gm Threaded ) 93 Non- Return Valves 94 C.I. / G.M. Non Return Valve With Flanges Etc. Complete As Per Specification Of The Following Sizes. 95 100 Mm Dia ( C.I. Flanged ) 96 25 Mm Dia ( Gm Threaded ) 97 Pressure Gaugesglycerine Fillied As Per Specifications ( 100 Mm Dial ) 98 Thermometer As Per Specifications ( 100 Mm Dial ) 99 Air Release Valveswith Isolation Ball Valves ( 20 Mm ) 100 Electrical Main Panel For Central Heating 101 Main Control Panel Having Separate Cubicals For Each Equipment ( Viz. Hot Water Generator 2 NoS, Hot Water Circulation Pumps 2 NoS, Soft Water Pumps 2 NoS, Softener Pump 1 No, Hsd Transfer Pump 2 NoS, 3 Kw Heater 1 No And Three Empty ) With Main And Individual Switch Gears For Hot Water Generator / Pumps And Starters For Pumps, On-Load Change Over Switch ( 160 A ) , Mccb ( 160A ) . The Control Panel Shall Be Provided With The Copper Bus Bars Dully Insulated Of Required Ratings As Per Specifications 102 Cable Try 103 300 Mm Wide Perforated Cable Tray Of 2 Mm Thickness And Supported From Ceiling The Wall Duly Painted As Per Site Condition 104 Conduits 105 Ms Conduit Pipes 106 Electrical Cable 107 Providing And Fixing Pvc Insulated Unarmoured Copper Conductor Cables From Main Panel Board To Various Equipments Through Walls / Ceiling With Appropriate Clamps And Fixing Arrangements, Cable Tray Etc. As Per Specifications 108 4 Core - 4 Sqmm 109 4 Core - 2.5 Sqmm 110 3 Core - 4 Sqmm 111 2 Core - 1.5 Sqmm 112 Earthing Pit 113 Earthing For Various Equipments Inside Boiler House Using Copper Plate Electrode Of Size600 X 600X 5 Mm Placed In 1000 X 1000X 1800 Mm Pit Filled With Charcoal & Salt By Copper Strip Of Size25 X 3 Mm Alongwith Perforated G.I Pipe As Per Specifications 114 Earthing Strip 115 Copper Strip Of Size 25X5 Mm From Earthing Electrode To The Panel, Stabilizer, Boiler And Pumps Using Proper Fastners Conceeled Under Floor.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 09-09-2022 Date Extension Date 22-09-2022
2 23-09-2022 Date Extension2 Date 06-10-2022

Key Value

Document Fees
INR 2500 /-
EMD
INR 215000.0 /-
Tender Value
INR 1.06 Crore /-
Disclaimer :