| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-09-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-09-2022 |
| 2 | 24-08-2022 | BoQ, Sch of credit and PS | BOQ | 02-09-2022 |
| Sl. No. | Item Description |
| 1 | B/R WORKS |
| 2 | Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified. |
| 3 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified. |
| 4 | Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified. |
| 5 | PCC type E-2 (1:5:10), using 40 mm graded stone aggregates as in filling & mass concrete, sub base, complete all as specified. |
| 6 | Cement concrete, type B-1 (1:2:4), using 20 mm graded stone aggregates as in lintels up to 1.5 metre clear span, bed blocks, copings and the like including weathering, slightly rounded or chamfered angles & throating including provision of necessary formwork, complete all as specified. |
| 7 | RCC type B-1 (1:2:4), using 20 mm graded stone aggregates as in shelves / cooking platform etc like including necessary formworkcomplete all as specified. |
| 8 | Brick work using bricks as specified in PS-II clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified. |
| 9 | Brick work half brick thick wall using bricks as specified in PS-II clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified. |
| 10 | Cutting chases pinning in making good to facing where required and pointing in cement mortar (1:3) for concealed water tubing in brick walls cutting n.exc 10 cm girth. complete all as specified. |
| 11 | Factory made 35 mm thick ,2nd class hard woodGlazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a);,etc complete all all as specified. |
| 12 | Factory made 2nd class hard wood rail and style, thicknesss of shutters,35 mm, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated,etc complete all all as specified. |
| 13 | Factory made solid PVC Door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforcedwith mild steel square tube, suppling & fixing in opening, complete all as specified. |
| 14 | Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plan colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rail, lock rail and bottom rail, panelling of wood grain colour PVC sheet to be fitted in the MS frame welded / sealed to the stile and rails with suitable PVC sheet beading and jointed together with solvent cement as specified in SSR Part II, complete all all as specified. |
| 15 | Aluminium anodised barrel tower bolt of extruded section 150mm long, ISI marked, complete all as specified. |
| 16 | Stainless steel butt hinges100 mm long, ISI marked, complete all as specified. |
| 17 | Stainless steel butt hinges 75 mm long, ISI marked, complete all as specified. |
| 18 | Aluminium handles anodised cast type 125mm long, ISI marked complete all as specified. |
| 19 | Aluminium alloy, anodised, ISI marked sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extrudedsections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 250mm long, IN REPAIR, complete all as specified. |
| 20 | Mild steel helical door spring200mm, ordinary rat tail rod pattern including roller and roller plate ISI marked, complete all as specified. |
| 21 | Double leg aluminium anodised door stopper with rubber foot, ISI marked and fixed with steel screws to bottom rail of doors complete all as specified. |
| 22 | Stainless steel conduit 20 mm bore, cut to size and erected in position including provison SS brackets & PVC decorative type finial (Two nos for each opening)IN REPAIRS, complete. |
| 23 | Galvanised steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks or galvanised wire staplesall as specified. |
| 24 | Framed mild steel work such as grills, grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290-Gde E-165, IN REPAIRS, complete all as specified.NOTE: Grill shall be factory fabricated and supplied duly welded to window frame with shop coat of red oxide primer. |
| 25 | Mild steel TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 26 | Pressed steel frames made out mild steel sheet 1.25 mm thick,for doors with one or more rebates including necessary fixing lugs, 100 mm size butt hinges, lock strike plates etc and applyinga shop coat of red oxide primer including providing PCC (1:3:6)type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified for size of frame: - |
| 27 | 105 mm x 60 mm |
| 28 | 125 mm x 60 mm |
| 29 | Factory made steel windows with side hung shutter with glazing bars each shutter having 02 No. box type hinges & two nos. tower bolts of size not less than 150 mm size and peg stays, dovetailed or welded,including one shop coat of zink chromate primer complete. |
| 30 | Factory made steel windows with side hung shutter without glazing barseach shutter having 02 No. box type hinges & two nos. tower bolts of size not less than 150 mm size and peg stays, dovetailed or welded,including one shop coat of zink chromate primer complete. |
| 31 | Steel windows or ventilators, fixed type including one shop coat of zink chromate primer complete. |
| 32 | NOTES APPLICABLE TO SERIAL ITEM NO. 26 TO 28: Profile section used under these items shall be \"P\" tube as shown in drawing No. CE/AF/STD-170/07, CE/AF/STD-171/07 and CE/AF/STD-172/07 as applicable. |
| 33 | Water Proofing Treatment to RCC sunken surfaces comprising of : - |
| 34 | Rendering15 mm thick (Average thickness) rendering on sunken surfaes including flashings, finished even and fairin cement mortar (1:4), using water proofing compound as per recommended ratio, after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified. |
| 35 | LDPE sheet 150 micron laid over applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. m & adjoining vertical surfaces including applying bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces complete all as specified. |
| 36 | Water Proofing Treatment to RCC roofs comprising of : - |
| 37 | Taking down existing water proofingtreatment (any no. of layers) from RCC roofs includingcleaning the surface including flashings and junction of parapet etc. with wire brushing & water to the entire satisfaction of EIC, complete all as specified. |
| 38 | PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, laid to slope as directed by Engineer in Charge over RCC roofs as padding, complete all as specified. |
| 39 | Rendering15 mm thick (Average thickness) rendering on roof surface including flashings and junction of parapets etc., finished even and fairin cement mortar (1:4), using water proofing compound as per recommended ratio, after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ. |
| 40 | APP modified water proofing membrane with non-woven polyester reinforcement, superior multi poly meric weighing not less than 3.5 kg / Sq.mlaid on primed roofs & flashing by forced application using Butane torch and sealing all joints on primed surface by applying hot blown industrial grade bitumen @ 85/25 @ 1.20 kg/Sq.m over a coat of bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces & flashings complete, all as specified. |
| 41 | 40 mm thick brick tiles are bedded over 15 mm thick cement mortar (1:4),and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on APP membrane,complete all as specified. |
| 42 | 40 mm thick brick tiles (Except Tiles) are bedded over 15 mm thick cement mortar (1:4),and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on APP membrane, , complete all as specified. |
| 43 | Making benching with PCC (1:2:4) type B-0 (using water proofing compound) along side walls adjoining to roofs, in CONCAVE SHAPE,complete all as specified. NOTE: WPC will be measured and paid for separately under respective item of BoQ. |
| 44 | NOTES APPLCABLE TO SERIAL ITEM 29 & 30: (a) Item for demolition of mud phuska, dismantling of brick tiles on RCC roofsand supply only WPC will be measured and paid for separately under respective item of BoQ.(b) For Guarantee of Water Proofing Treatment refer PS clause 11.5 of CA. |
| 45 | Supply only water proofing compound (WPC), ISI marked, complete all as specified. |
| 46 | uPVC pipes, 110 mm external dia pipe, type-A, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed to wall with PVC bracketsas rain water pipes, IN REPAIRS, complete all as specified |
| 47 | uPVC bends any radius, suitable for 110 mm external dia pipe, type-A uPVC pipes,complete all as specified. |
| 48 | 25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished rough, as in sub floors or similar locations, complete all as specified. |
| 49 | 75 mm thick, cement concrete type C-1, 1:3:6 using 20 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection,and joints shall be sealed with joint sealing comound grade \"A\" complete all as specified. |
| 50 | 75 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified. |
| 51 | Machine cut Kota stone slab flooring 18-22 mm thick, area of each slab not less than 0.30 sq.m, (cut to size in square shape) laid over & including 20 mm thick (average thickness) cement mortar (1:3) screed and jointed with grey cement slurry mixed with matching shade pigment including rubbing and polishing (Granite finish) complete, all as specified. |
| 52 | Kota stone slab 15-18 cm thick on vertical surfaces like riser of steps, skirting, dado and pillar laid over & including 10 mm thick (average thickness) cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (Granite finish), complete all as specified. |
| 53 | Granite jet black shade, 15-18 mm thick,as in step, jambs, cooking platform and like, machine cut, machine polished,bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified. |
| 54 | Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified. |
| 55 | Glazed ceramic coloured tiles600mm x 300mm x 7mm thick on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified. |
| 56 | Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.11 Sq.m but n. exc. 0.18 Sq.m laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement with pigment to match the shade of tile laid over and including 15 mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement complete all as specified. |
| 57 | Factory made, machine pressed precast concrete interlocking paver block any shape and size approved by EIC, ISI marked (IS:15658-2006) of 60 mm thick,M-35 grade, with grey cement & pigment,laid dry in paths/roads incliuding over sand Clean dry sand filling, 25 mm thick consolidated thickness,complete all as specified. |
| 58 | Rendering 10 mm thick on fair faces of concrete surfaces, finished fair and even on ceiling surfacesin cement mortar (1:3), complete all as specified. |
| 59 | Rendering 15 mm thickon fair faces of brick work or concrete surfaces, finished even and fairon walls in cement mortar (1:6)complete all as specified. |
| 60 | Rendering 15 mm thickon fair faces of brick work or concrete surfaces, finished even and fairon walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified. |
| 61 | Cutting out natural vegitation plants grown up o wall or roof and making good the damaged portion to match with with the existing cement concrete complete. |
| 62 | Repairinging of damaged swollen RCC surfaces like projections chhajjas, facia, parapet etc including necessary scraping, cutting, chiseling, derusting and cleaning exposed reinforcement, washing apply cement slurry @ 3 kg/Sq.m and fiishing the surface with cement concrete (1:1.5:3) using 12.5 mm graded stone aggregate incl reinforced with chicken wire mesh or welded mesh having weight not more than 3 kg/Sq.m as reinforcement with and/or finished the repairedsurface with cement and sand mortar (1:3) using WPC and work in patches area n.exc 5 Sq.m incl necessary formwork, complete all as specified.NOTE:Quoted rate shall includes the cost of scaffolding/shuttering upto 15 metre height. |
| 63 | NOTE APPLICABLE FOR SERIAL ITEM 40 to 42: Supply only water proofing compound (WPC) will be easured & paid separately uder respective item of BoQ. |
| 64 | Prepration of oldplastered or un-plastered surface of ceiling and applying one coat of white wash complete all as specified. |
| 65 | Three coats of white washing on new plastered ceiling surfaces, including preparation ofsurfaces, complete all as specified. |
| 66 | Complete removal of existing treatment of any description, including prepration of wall surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty, in two coats& smoothening the surfaces as specified. (preparatory to paint as directed).(b) Two coats of interior acrylic distemperover and including a coat of interior primer. |
| 67 | Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty, in two coats& smoothening the surfaces as specified. (preparatory to paint as directed).(b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of primer. |
| 68 | Complete removal of existing treatment of any description, including prepration of wall surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty, in two coats& smoothening the surfaces as specified. (preparatory to paint as directed).(b) Two coats of exterior acrylic emulson over and including a coat of water based exterior primer. |
| 69 | Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty, in two coats& smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of exterior acrylic emulsion over and including a coat ofwater based exterior primer. |
| 70 | NOTES APPLICABLE TO SERIAL ITEM NO. 52 TO 55: (i) Entire quantity of material for this work shall be procured by the contractor from manufacturer\"s Depot & deposit the same with Enginer-in-Charge and same shall be issued to contractor on daily basis as per consumption at site. (ii) The work shall be got executed through paint manufacturer/ authorised applicators of manufacturer\"s as specified in relevent PS clause. |
| 71 | Sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq.min each paneincluding hacking out old broken glass (any thickness, size, quality or description) from wooden/ metal frame including punching or drilling out old glazing pins/spring clipscomplete all as specified. |
| 72 | Sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq.min each pane complete all as specified. |
| 73 | Figured glass, 4 mm thick, pin head type and glazing with linseed oil pane putty & spring glazing clips, in squaresexceeding 0.5 sq.m in each pane, complete all as specified. |
| 74 | Preparation of newwood and wood basedsurfaces of any description not other wise described over 10cm width or girth and applying two coatsof synthetic enamel paint over & including a coat of pink primer complete all as specified. |
| 75 | Two coats of synthetic enamel paint over & including a coat of red oxide primer oversteel & iron (new) surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified. |
| 76 | Steel tubes ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors IN REPLACEMENT, of size: - |
| 77 | 15mm bore |
| 78 | 20mm bore |
| 79 | 1000 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with closed top) including hoisted and fixed in position, making connections,IN-REPAIRS, complete all as specified including the following acessories: -(i) PTMT ball valves, high pressure, with epoxy coated aluminium rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, IN REPAIRS, complete all as specified.(iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for GI tubes 20 mm bore, ISI marked, screwed both ends for iron pipe, IN REPAIRS, complete all as specified.(iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP. |
| 80 | Angular stop valve/cock, cast copper alloy, chromium plated, with wall flange,quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: PRAYAG Cat No. 6810 or equivalent make mentioned in Appndix \"B\". |
| 81 | Concealed stop valve/cock, cast copper alloy, chromium plated, with wall flange,quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: PRAYAG Cat No. 6818 or equivalent make mentioned in Appndix \"B\". |
| 82 | Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange,quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: PRAYAG Cat No. 6808 or equivalent make mentioned in Appndix \"B\". |
| 83 | Centre hole basin mixer, swan neck type, cast copper alloy, chromium plated, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete.MAKE:PRAYAG Cat No. 6850 or equivalent make mentioned in Appndix \"B\". |
| 84 | 100 mm size overhead cross flow ABS shower with cast copper alloy chromium plated arm 150 mm long with flange and fixed in position, IN REPAIRS, complete.MAKE:PRAYAG Cat BOS-100 or equivalent make mentioned in Appndix \"B\". |
| 85 | Stainless steel towel rail600 mm long, fixed to wall with SS screws and PVC rawl plugs, IN REPAIRS,complete.MAKE: PRAYAG Cat No.BA-10S or equivalent make mentioned in Appndix \"B\". |
| 86 | PVC connections 15 mm size of length 450 mm with PTMT nuts, IN REPAIRS complete all as specified. |
| 87 | PTMT shelf 450 mm longfixed with and including steel screws and plastic plugsIN REPARS, complete all as specified.MAKE: PRAYAG Cat No.191 or equivalent make mentioned in Appndix \"B\". |
| 88 | Stainless steel (304 grade) grating with frame, with or without hole 100-110 mm size, IN REPAIRS, complete all as specified. |
| 89 | Vitreous China wash down water closet pan (pedestal pattern of size 540x 365x390 mm), white ISI marked,includingfixing acessories, IN REPAIRS, complete all as specified. |
| 90 | PVC water closet seat and white cover, ISI marked, with & including mild steel chromium plated hinging device & rag bolts, IN REPAIRS, complete all as specified.MAKE: PRAYAG Cat No. 515 or equivalent make mentioned in Appndix \"B\". |
| 91 | Jet spray (L-bend), stainless steel body withbraded tube 1.50 metre tube IN REPAIRS, complete.MAKE:PRAYAG Cat BEA-18or equivalent make mentioned in Appndix \"B\". |
| 92 | Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, ISI marked, white, with integral foot rests (excluding flushing cistern and flush pipe), IN REPAIRS, complete all as specified. |
| 93 | PVC flushing cistern 6 litre capacity, syphonic action type, any shade, with side handle, ISI marked (IS: 7231) with flush pipe and all fixing arrangements, IN REPAIRS, complete all as specified. |
| 94 | Vitreous China wash basin, white, flat back, size 550 x 400 mm ISI marked, complete all as specified. including fixing acessories like rag bolts etc. with PTMT waste coupling half or full threaded suitable for & including 32 mm size PVC discharge pipe,IN REPAIRS, complete. |
| 95 | Looking mirror 600 x 600 mm, selected quality glass 6 mm thick, with beveled edges having back side support of thermoplastic sheet 2 mm thick pasted with vacuum pressure technique and provision of silicon coating on beveled edgesfixed on location with 4 nos. steel studs of suitable size with plastic washers on back side, IN REPAIRS, complete. |
| 96 | Vitreous China Urinal Pot (345 mm x 320 mm x 560 mm), half stall type, ISI marked, white, with and including all fixing acessories like rag bolts etc. with & including 32 mm size PTMT urinal waste coupling & 32 mm size cllapsible PVC waste pipe, IN REPAIRS, complete all as specified. |
| 97 | Stainless steel sink, single bowl type, matt finish, made out of SS-304 sheet not less than 1 mm for kitchen with & including plug waste pipe, washers connecting union etc including necessary fixing acessories, overall size 510mmx430X203 mm with bowl size 430mm x 380mm x203mm IN REPLACEMENT, complete. MAKE: PRAYAG Cat P-1318D or equivalent make mentioned in Appendix \"B\". |
| 98 | Stainless Steel kitchen plate rack of sheet thickness not less than 0.61 mm overall size 786 x 760 x 254 mm, fixed on walls wth PVC plugs and SS screws, INREPAIRS, complete.MAKE: PRAYAG Cat No. P-346 or equivalent make mentioned in Appndix \"B\". |
| 99 | Cast iron spun type soil waste and vent pipe in any length with or without ears with cement joints laid in trenches or under floors, IN REPAIRS, complete all as specified, of size: - |
| 100 | 75 mm bore |
| 101 | 100 mm bore |
| 102 | Cast iron spun type soil waste and vent pipe in any length with or without ears with cement joints fixed to walls, IN REPAIRS, complete all as specified, of size: |
| 103 | 75 mm bore |
| 104 | 100 mm bore |
| 105 | Cast iron bends (any radius), diminishing pieces or tapers (largrer bore measured) with oval acess door,ISI marked, complete all as specified,IN REPAIRS, suitable for spun pipes of size: - |
| 106 | 75 mm bore |
| 107 | 100 mm bore |
| 108 | Cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval acess door, ISI marked, suitable for spun pipe of size 100 mm bore, IN REPAIRS, complete all as specified. |
| 109 | Cast iron branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval acess door, ISI marked, suitable for spun pipe of size 100 mm bore, IN REPAIRS, complete all as specified. |
| 110 | Cast iron cowl, suitable for 100 mm bore spun pipe, ISI marked, IN REPAIRS, complete all as specified. |
| 111 | 100 mm cast iron sanitary connection socket to fit WC out-let, IN REPAIRS, complete all as specified. |
| 112 | 100 mm cast iron sanitary connections short connections pipe of length upto 300 mm, IN REPAIRS, complete all as specified. |
| 113 | Cast iron floor trap,ISI marked, including jointing to waste pipe and fixed in cement concrete type B-1 (1:2:4)complete all as specified, IN REPAIRS, suitable for spun pipes of size: - |
| 114 | 75 mm bore |
| 115 | 100 mm bore |
| 116 | uPVC pipes, 75 mm external dia pipe, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed to wall with PVC bracketsas rain water pipes, IN REPAIRS, complete all as specified. |
| 117 | uPVC bends any radius, suitable for 75 mm external dia pipe, type-B uPVC pipes, IN REPAIRS, complete all as specified. |
| 118 | Concrete bed to drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 typeC-2, complete all as specified. |
| 119 | Reinforced concrete pipes 150 mm bore, class NP-2, laid and jointed complete with collars, laid in trenches and jointed, ISI marked, complete all as specified. |
| 120 | E/M WORKS |
| 121 | Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed FRLSH cable, including PVC insulated unsheathed stranded copper conductor single core FRLSH cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ socketscomprising the following: - |
| 122 | One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified. |
| 123 | One light point controlled by two 2 way switches with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified. |
| 124 | One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified. |
| 125 | One Socket outlet, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC heavy duty concealed conduit all as specified. |
| 126 | One socket outlet, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified. |
| 127 | NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule \"A\". (b) GI boxes shall be fixed flushto walls in position with cement mortar (1:4) complete all as directed.(c) Conduit shall be laid on surface in case of RCC ceiling surfaces. |
| 128 | Switch piano flush button single pole one way, 6 Amp complete all as specified. |
| 129 | Switch piano flush button single pole two way, 6 Amp complete all as specified. |
| 130 | Switch piano flush button single pole one way, 16 Amp complete all as specified. |
| 131 | Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified. |
| 132 | Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, flush type complete, all as specified. |
| 133 | Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified. |
| 134 | Lamp (angle) holder, insulated body, cord grip pattern, complete, all as specified. |
| 135 | Fan regulator (electronic) suitable for 48”/56” sweep fan, step type, single phase, complete all as specified. |
| 136 | Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified for the following: - |
| 137 | 2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable |
| 138 | NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately.(ii)For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as \"1 RUNNING METRE\" |
| 139 | Rigid non metallic, PVC concealed conduit, 20 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified. |
| 140 | Sheet metal enclosure SPN, 12 way with 200 Amp rated bus bar, 240 V, double door type for DB for fixing MCB’s, isolators etc., having IP-43 protection, surface and flush mounting, complete all as specified. |
| 141 | Sheet metal enclosure TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type for DB for fixing MCCB, MCB’s, isolators etc., IP-43 protection, having housing & including 63 Amp 4 pole MCCB, surface and flush mounting, complete all as specified. |
| 142 | MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, \"C\" curve type of rating6 to 32 Amp complete all as specified. |
| 143 | MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, \"C\" curve type of rating 6 to Amp complete all as specified. |
| 144 | Blanking plate to cover unused space in DB\"s complete all as specified.. |
| 145 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 volt, breaking capacity not less than 10 kA, complete all as specified. |
| 146 | Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 4 Sq. mm GI wire earthing lead including test point complete all as shown in electrical plate No. 3 and specified in Particular Specifications clause 19.3.1 of contract, IN REPAIR.NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate.(b) Factory made precast PCC pit with cover shall be fixed at least 500 mm away from earth pit. |
| 147 | Environment friendly, energy saving surface mounted, decorative 6.5 W bulk head LED luminaire with premium quality diffuser for glarefree light, 6000Kcomplete.MAKE: Havells Cat Part No. LHEXCGP7ION5W006 or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 148 | Surface mounted Environment friendly decorative ultra slim almn LED 22 W lighting 6500K, lumen output should not be less than 90 lumens per watt complete.MAKE: Havells Cat Part No. LHEXBTP7IN1S022 or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 149 | Disconnectiing & taking down exhaust fan 300-450 mm sweep from existing location and refixing & reconnecting the same on orginal or new location after misc service and provn of 04 no. 10 mm size fasteners, complete. |
| 150 | Disconnectiing & taking down water storage geyser 25-50 litre from existing location and refixing & reconnecting the same on orginal or new location after misc service and provn of 04 no. 10 mm size fasteners, complete. |
| 151 | Disconnectiing & taking down light fitting of any description from existing location and refixing & reconnecting the same on orginal or new location after cleaning, complete. |
| 152 | DEMOLITION/DISMANTLING WORKS |
| 153 | Taking down cement plaster of any description on brick walls or concrete surfaces etcincluding raking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 154 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sq.m each and removing from site all as specified. |
| 155 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sq.m but not exceeding 4.00 Sq.m each and removing from site all as specified. |
| 156 | Taking down shutters of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each and refixing in the same opening after easing adjusting and minor REPAIRS complete all as specified. |
| 157 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified. |
| 158 | Demolition brickwork or stone / boulder masonrybuilt in cement mortar including all quoins, arches, pillars etc complete all as specified. |
| 159 | Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified |
| 160 | Demolition of cement concrete (unreinforced)of any description and in any position not otherwise specifically provided all as specified. |
| 161 | Demolition of reinforced cement concreteof any description and in any position not otherwise specifically provided all as specified. |
| 162 | Demolition of mud phuska in roofs, any thickness including plaster and leeping plaster (whether full thickness removed or only part thereof) all as specified. |
| 163 | Dismantlig brick tiles in roof laid dry and pointed in cement mortar all as specified. |
| 164 | Demolition and breaking up drain pipes 150 bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, including PCC bedding as required and haunching, complete all as specified |
| 165 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified. |
| 166 | Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified. |
| 167 | Dismantling of unservisible existing DBs of any description with all accessories and MCBs, isolators etc.and making good surface as per existing, complete all as specified. |
| 168 | Taking down carefully light fitting of any description, complete all as specified. |
| 169 | NOTE:Amount ofcredit for retrieved materials is mentionedintender documents in pdf form which will be deducted while acceptance of tender offline. |