}

Hiring Services For Supply & Installation Of Lightning Protection Materials In Priority-1 Areas Of Bcpl, Lepetkata Plant- Short Text : Air Terminal D 8 Mm L 500 Mm, Almgsilong Text :Supply And Installation Of 500 Mm Air Termination Rod. Diameter Ø- 8 M, Dibrugarh-Assam

Brahmaputra Cracker And Polymer Limited has published Hiring Services For Supply & Installation Of Lightning Protection Materials In Priority-1 Areas Of Bcpl, Lepetkata Plant- Short Text : Air Terminal D 8 Mm L 500 Mm, Almgsilong Text :Supply And Installation Of 500 Mm Air Termination Rod. Diameter Ø- 8 M. Submission Date for this Tender is 26-08-2022. Marking Tools Tenders in Dibrugarh Assam. Bidders can get complete Tender details and download the document.




Tender Notice

33431615
Corrigendum : Hiring Services For Supply & Installation Of Lightning Protection Materials In Priority-1 Areas Of Bcpl, Lepetkata Plant- Short Text : Air Terminal D 8 Mm L 500 Mm, Almgsilong Text :Supply And Installation Of 500 Mm Air Termination Rod. Diameter Ø- 8 M
Open Tender
Indian
Assam
Dibrugarh
26-08-2022

Tender Details

Hiring Services For Supply & Installation Of Lightning Protection Materials In Priority-1 Areas Of Bcpl, Lepetkata Plant- Short Text : Air Terminal D 8 Mm L 500 Mm, Almgsilong Text :Supply And Installation Of 500 Mm Air Termination Rod. Diameter Ø- 8 Mm, Cross-Section- 50 Mm2, Of Material- Almgsi ( Alloy Grade - 6060 ) & Complied As Per Standard Iec 62561-2. 2 Short Text : Air Terminal D 8 Mm L 700 Mm, Almgsilong Text :Supply And Installation Of 700 Mm Air Termination Rod. Diameter Ø- 8 Mm, Cross-Section- 50 Mm2, Of Material- Almgsi ( Alloy Grade - 6060 ) & Complied As Per Standard Iec 62561-2. 3 Short Text : Air Terminal D 10 Mm L 1000 Mm, Almgsilong Text :Supply And Installation Of 1000 Mm Air Termination Rod. Diameter Ø- 10 Mm, Material- Al & Complied As Per Standard Iec 62561-2. 4 Short Text : Air Terminal D 16 Mm L 1500 Mm, Almgsilong Text :Supply And Installation Of Air-Termination Rod Having Length- 1500 Mm, Material- Almgsi, Diameter Ø- 16 Mm, Complied And Tested As Per Standard Iec 62561-2. 5 Short Text : Air Terminal D 16 Mm L 2000 Mm, Almgsilong Text :Supply And Installation Of Air-Termination Rod Having Length- 2000 Mm, Material- Almgsi, Diameter Ø- 16 Mm, Complied And Tested As Per Standard Iec 62561-2. 6 Short Text : Air Terminal D 16 Mm L 2500 Mm, Almgsilong Text :Supply And Installation Of Air-Termination Rod Having Length- 2500 Mm, Material- Almgsi, Diameter Ø- 16 Mm, Complied And Tested As Per Standard Iec 62561-2. 7 Short Text : Air Terminal D 16 Mm L 3000 Mm, Almgsilong Text :Supply And Installation Ofair-Termination Rod Having Length- 3000 Mm, Material- Almgsi, Diameter Ø- 16 Mm, Complied And Tested As Per Standard Iec 62561-2. 8 Short Text : Air Terminal D 16 / 10 Mm L 3.5 Mtr, Almgsilong Text :Supply And Installation Of Air-Termination Rod Having Length- 3500 Mm, Material- Almgsi, Diameter Ø- 16 / 10 Mm, Complied And Tested As Per Standard Iec 62561-2. 9 Short Text : Tripod Air Terminal D 22 / 16 / 10 Mm L 3.5Long Text :Supply And Installation Of Self-Supporting Air-Termination Rod With Tripod Having Length 3500 Mm, Adjustable To A Roof Inclination Up To Max. 10 Degrees. Max. Gust Wind Speed - 130 Km / H. Height: 3500 Mm, Dia - 22 / 16 / 10 Mm Material Of Air-Termination Rod: Al Material Of Tripod: St / Tzn Complied And Tested As Per Standard: Iec 62561- ( 1+2 ) 10 Short Text : Tripod Air Terminal D 40 / 22 / 16 / 10 Mm L 4Long Text :Supply And Installation Of Self-Supporting Air-Termination Rod With Tripod Having Length 4500 Mm, Adjustable To A Roof Inclination Up To Max. 10 Degrees. Max. Gust Wind Speed - 180 Km / H. Height: 3500 Mm, Dia - 40 / 22 / 16 / 10 Mm Material Of Air-Termination Rod: Al Material Of Tripod: St / Tzn Complied And Tested As Per Standard: Iec 62561- ( 1+2 ) 11 Short Text : Air Terminal D 40 / 16 / 10 Mm L 5.5 Mtr, Allong Text :Supply And Installation Of Air-Termination Rod Having Total Length Of 5500 Mm< ( >, , < ) > Dia - 40 / 22 / 16 / 10 Mm, Max. Gust Wind Speed - 180 Km / H. Material Of Air-Termination Rod: Al Complied And Tested As Per Standard: Iec 62561- ( 1+2 ) 12 Short Text : Air Terminal D 40 / 16 / 10 Mm L 6.5 Mtr, Allong Text :Supply And Installation Of Air-Termination Rod Having Total Length Of 6500 Mm< ( >, , < ) > Dia - 40 / 22 / 16 / 10 Mm, Max. Gust Wind Speed - 180 Km / H. Material Of Air-Termination Rod: Al Complied And Tested As Per Standard: Iec 62561- ( 1+2 ) 13 Short Text : Clamp For 0.5 M Air Terminallong Text :Supply And Installation Of Parallel Clamp To Connect D 8Mm L 500Mm Air Termination Rod, Material - Stst, Clamping Range Rd / Rd 7-10 Mm & Complied As Per Standard Iec 62561-1. 14 Short Text : Clamp For 0.7 M Air Terminallong Text :Supply And Installation Of Parallel Clamp To Connect D 8Mm L 700Mm Air Termination Rod, Material - Stst, Clamping Range Rd / Rd 7-10 Mm & Complied As Per Standard Iec 62561-1. 15 Short Text : Clamp, F / Metal, Strip, 1-12 Mmlong Text :Supply And Installation Of Clamps For Connection To Steel Constructions And Steel Sheets< ( >, < ) > Clamping Range- 1-12 Mm Material Of Clamp- Mci / Tzn, Clamping Range Rd- 7-10 Mm, Material Of Screw / Nut: Stst Complied And Tested For Minimum 50 Ka Lightning Curriect ( @ 10 / 350 Μsec ) As Per Standard Iec 62561-1. 16 Short Text : Clamp, F / Metal, Strip, 0.4-12 Mmlong Text :Supply And Installation Of Clamps For Connection To Steel Constructions And Steel Sheets< ( >, < ) > Clamping Range- 0.4-12 Mm Material Of Clamp- Mci / Tzn, Clamping Range Rd- 7-10 Mm, Material Of Screw / Nut: Stst Complied And Tested For Minimum 50 Ka Lightning Curriect ( @ 10 / 350 Μsec ) As Per Standard Iec 62561-1. 17 Short Text : Side Wall Clamp For Air Terminallong Text :Supply And Installation Of Clamp To Connect Air Termination Rod On Side Wall Material: Stst 304 Clamping Range Of Air Termination Rod- Rd 16 / 10 Mm 18 Short Text : Plastic Cover For Concrete Baselong Text :Supply And Installation Of Plastic Support Plate For Concrete Base For Protecting The Roofing Sheets Under The Concrete Base ( 17 Kg ) . Material: Eva 19 Short Text : Concrete Block 17 Kglong Text :Supply And Installation Of Concrete Base For Air-Termination Rods And For Self-Supporting Air-Termination Rods In The Tripod. Material- Concrete, Material Of Wedge- Stst & Weight 17Kg Support- Wedge Mounting Ø16 Mm 20 Short Text : Air-Termination Rod Clamp 10 Mmlong Text :Supply And Installation Of Air-Termination Rod Clamps 10 Mm For Connecting Air-Termination Rods To Roof Conductor, Iec 62561-1 21 Short Text : Air-Termination Rod Clamp 16 Mmlong Text :Supply And Installation Of Air-Termination Rod Clamps 16 Mm For Connecting Air-Termination Rods To Roof Conductor, Iec 62561-1 22 Short Text : Adjustable Wall Mounting Bracketlong Text :Supply And Installation Of Adjustable Wall Mounting Bracket For Air Termination Rod And To Bond Round Conductor Adjustable Distance From Wall: 150 - 200 Mm Clamping Range For Air Termination Rod: D 40-50 Mm Clamping Range For Round Conductor: D 8-10 Mm Standard: Iec 62561- ( 1+2 ) 23 Short Text : Fastner With Nut Boltlong Text :Supply And Installation Of Anchor Fastener Size-M10x50 Mm, Material-Ss Nut Bolt Size-M8x50 Mm, Material-Ss 24 Short Text : Roof Cond. D 8 Mm, Almgsilong Text :Supply And Installation Of Round Conductor Of Diameter Ø- 8 Mm< ( >, < ) > Cross-Section- 50 Mm2, Material- Almgsi ( Alloy Grade - 6060 ) < ( >, < ) > 25 Short Text : Roof Conductor Holder For Flat Rooflong Text :Supply And Installation Of Roof Conductor Holder For Flat Roofs With Concrete Block Of 1 Kg With Double Conductor Holder Clamping Range Rd: 8 Mm Fixed Holder Material: Plastic 26 Short Text : Conductor Holder, Stst With Plastic Baselong Text :Supply And Installation Of Roof Conductor Holder For Parapet / Side Wall, Material Of Roof Conductor Holder Stst With Plastic Base, Conductor Holder Support Rd 8-10 Mm, Standard En 62561-4 Conductor Holder For Parapet / Side Wall Of Material- Stst With Plastic Base, Is Capable Of Holding Rd 8-10 Mm & Complied As Per Standard En 62561-4. 27 Short Text : Conductor Holder, Ststlong Text :Supply And Installation Of Roof Conductor Holder For Metal Sheet Roof, Material Of Roof Conductor Holder Stst, Conductor Holder Support Rd 8-10 Mm, Standard En 62561-4 Conductor Holder For Metal / Sheet Roof Of Material- Stst, Is Capable Of Holding Rd 8-10 Mm & Complied As Per Standard En 62561-4. 28 Short Text : Adhesive For Metal To Metallong Text :Supply And Installation Of Glue ( 400 Ml Cartridge ) For Fixing Metal Holder To Metal / Sheet< ( >, < ) > Qnty. Per Drop / Holder: 2-2.5 Ml 29 Short Text : Glue Dispenserlong Text :Supply Of Dispenser For Metal To Metal Glue 30 Short Text : Universal Connector D 8-10 Mm, Ststlong Text :Supply And Installation Of Universal Connector For Interconnecting Roof Conductor & Down Conductor Material- Stst With Clamping Range- 8-10Mm, With Truss Head Screw The Clamp Should Be Complied And Tested For Minimum 50 Ka Lightning Current ( @ 10 / 350 Μsec ) As Per Standard En 62561-1. 31 Short Text : Cross Connector D 8-10 / Fl 30 Mm, Ststlong Text :Supply And Installation Of Cross Clamp For Aboveground And Underground Application, Clamp Material - Stst ( V4a ) Clamping Range Rd / Rd: 8-10 / 8-10 Mm Clamping Range Rd / Fl: 8-10 / 30 Mm Clamping Range Fl / Fl: 30 / 30 Mm The Clamp Should Be Complied And Tested For Minimum 100 Ka Lightning Current ( @ 10 / 350 Μsec ) As Per Standard En 62561-1. 32 Short Text : Pipe Clamp D 16-165 / 10 Mm, Ststlong Text :Supply And Installation Of Pipe Clamp For Lightning Equipotential Bonding Of Pipes ( E.G. Antenna Masts ) According To Iec / En 62305-3. Material Of Clamp - Stst, Having Clamping Range Pipe- Ø 16-165 Mm, Connection Of Round Conductor: Rd Ø6-8 Mm / 1X Ø10 Mm, The Clamp Should Be Complied And Tested For Minimum 100 Ka Lightning Current ( @ 10 / 350 Μsec ) As Per Standard En 62561-1. 33 Short Text : Pipe Clamp D 50-300 / 16 Mm, Ststlong Text :Supply And Installation Ofpipe Clamp To Hold Air Termination Rod Having Dia 16 Mm Material Of Clamp- Stst, Clamping Range For Square / Pipe: 40X60 Mm To 70X70 Mm / Ø 50-300 Mm, Clamping Range For Round: 16 Mm The Clamp Should Be Complied And Tested For Minimum 100 Ka Lightning Current ( @ 10 / 350 Μsec ) As Per Standard En 62561-1. 34 Short Text : Metal Connection Clamp 18-35 Mm, Ststlong Text :Supply And Installation Of Connection Clamps For Steel / Metal Column With Clamping Frame. Clamping Range Of The Clamp: 18-35 Mm< ( >, < ) > Material Of The Clamp- Stst, Clamping Range Of Conductor Rd: 6-10 Mm Complied And Tested For Minimum 50 Ka Lightning Current ( @ 10 / 350 Μsec ) As Per Standard En 62561-1. 35 Short Text : Metal Connection Clamp 3-18 Mm, Ststlong Text :Supply And Installation Of Connection Clamps For Steel / Metal Column With Clamping Frame. Clamping Range Of The Clamp- 3-18 Mm< ( >, < ) > Material Of The Clamp- Stst, Clamping Range Of Conductor Rd 6-10 Mm Complied And Tested For Minimum 50 Ka Lightning Current ( @ 10 / 350 Μsec ) As Per Standard En 62561-1. 36 Short Text : Clamp To Connect Rd. Cond To Metal / Striplong Text :Supply And Installation Of Clamps For Connection To Steel Constructions And Steel Sheets< ( >, < ) > Clamping Range- 1-12 Mm Material Of Clamp- Mci / Tzn, Clamping Range Rd- 7-10 Mm, Material Of Screw / Nut: Stst Complied And Tested For Minimum 50 Ka Lightning Curriect ( @ 10 / 350 Μsec ) As Per Standard Iec 62561-1. 37 Short Text : Clamp To Connect Rd. Cond To Metal / Striplong Text :Supply And Installation Of Clamps For Connection To Steel Constructions And Steel Sheets< ( >, < ) > Clamping Range- 0.4-12 Mm Material Of Clamp- Mci / Tzn, Clamping Range Rd- 7-10 Mm, Material Of Screw / Nut: Stst Complied And Tested For Minimum 50 Ka Lightning Curriect ( @ 10 / 350 Μsec ) As Per Standard Iec 62561-1. 38 Short Text : Down Cond. D 8 Mm, Almgsilong Text :Supply And Installation Of Round Conductor Of Diameter Ø- 8 Mm< ( >, < ) > Cross-Section- 50 Mm2, Material- Almgsi ( Alloy Grade - 6060 ) < ( >, < ) > 39 Short Text : Conductor Holder, Stst With Plastic Baselong Text :Supply And Installation Of Roof Conductor Holder For Parapet / Side Wall, Material Of Roof Conductor Holder Stst With Plastic Base, Conductor Holder Support Rd 8-10 Mm, Standard En 62561-4 Conductor Holder For Parapet / Side Wall Of Material- Stst With Plastic Base, Is Capable Of Holding Rd 8-10 Mm & Complied As Per Standard En 62561-4. 40 Short Text : Conductor Holder, Ststlong Text :Supply And Installation Of Roof Conductor Holder For Metal Sheet Roof, Material Of Roof Conductor Holder Stst, Conductor Holder Support Rd 8-10 Mm, Standard En 62561-4 Conductor Holder For Metal / Sheet Roof Of Material- Stst, Is Capable Of Holding Rd 8-10 Mm & Complied As Per Standard En 62561-4. 41 Short Text : Adhesive For Metal To Metallong Text :Supply And Installation Of Glue ( 400 Ml Cartridge ) For Fixing Metal Holder To Metal / Sheet< ( >, < ) > Qnty. Per Drop / Holder: 2-2.5 Ml 42 Short Text : Lightning Impulse Counterlong Text :Supply And Installation Of Lightning Strike Counter Used To Count The Digital Impulse Currents. Device For Installation Preferably On Down Conductors Of The Lightning Protection System Or Between Equipotential Bonding Bar And Earth-Termination System. Operating Current ( 8 / 20 Μs ) - 1 Ka, Max. Max. Discharge Current ( 10 / 350 Μs ) : 100 Ka Clamping Range Of Rod / Flat: 8-10 / 30 Mm Number Of Occurrences: Up To 999 Operating Temperature Range: -20 °C To +60 °C Degree Of Protection: Ip 65 43 Short Text : Gi Flat 25X6mmlong Text :Supply And Installation Of Gi Flat ( 25X6mm ) Strip. Having Width- 25Mmthickness- 6Mm< ( >, < ) > Material- Hot Dipped Galvanized Iron Cross Section- 150 Mm2 Coating Thickness- Avg. 70 Microns. & Complied As Per Iec 62561-2. 44 Short Text : Test Link With Intermediate Platelong Text :Supply And Installation Of Test Link Clamps With Intermediate Plate For Round And Flat Conductor Material- Stst Clamping Range- Rd / Fl 8-10 / 30 Mm Complied And Tested For Minimum 150 Ka Lightning Current ( @ 10 / 350 Μsec ) As Per Standard En 62561-1. 45 Short Text : Gi Flat 25X6mmlong Text :Supply And Installation Of Gi Flat ( 25X6mm ) Strip. Having Width- 25Mmthickness- 6Mm< ( >, < ) >Material- Hot Dipped Galvanized Iron Cross Section- 150 Mm2 Coating Thickness- Avg. 70 Microns. & Complied As Per Iec 62561-2. 46 Short Text : Cross Clamp Fl 20-75 Mm, Gilong Text :Supply And Installation Of Cross Unit To Connect Flat Conductors Material: Gi Clamping Range Fl / Fl: 20 / 70 Mm 47 Short Text : Gi Strip Holderlong Text :Supply And Installation Of Gi Strip Holder- Insulated Holder Material Of Construction - Dow Moulded Compound Height 19 Mm ( Minimum ) , Slot Size- 25X6 Mm. 48 Short Text : Cu Bonded Earth Rod L 3 M D 17.2 Mmlong Text :Supply And Installation Of Copper Bonded Rod With Low Carbon Steel, High Tensile Strength Copper Bonded Rod With Min 250 Microns Of Copper Plating, Ul Listed. Diameter- 17.2 Mm, Length- 3 Meters, Material- Copper Bonded, Coating Thickness- 250 Microns, Min, Short Circuit Current Withstand Capability - 18 Kamp Rms For 1 Second. 49 Short Text : Fulgurite Free Ground Enhancement Comp.Long Text :Supply And Installation Of 20 Kg Backfilled Compound, - Rohs Compliant Graphite Based Fulgurite Free Backfill Compound Having Low Resistivity, Dose Not Decay Or Leach Out 50 Short Text : Earth Termination Clamp, Ststlong Text :Supply And Installation Of Earthing: Stst 316 Grade Clamp To Terminate The Load On Earth Electrode Material Of Construction - 316 Grade Stainless Steel< ( >, < ) > Dimension - 160X35x3 Mm 51 Short Text : Poly Plastic Pit Coverlong Text :Supply And Installation Of Poly Plastic Pit Cover Of Material- Polymer Body & Cover, Minimum Size - 308 Mm ( L ) X 308 Mm ( W ) X 214 Mm ( H ) , Load Bearing Capacity - 5 Ton. 52 Short Text : Type 1+2 Spd With Buil-In Fuse L-Nlong Text :Supply And Installation Of Spark Gap Based Metal Encapsulated Lightning Current & Surge Protection Device At Mains Lt Panel ( 3 Phase, 415 V ) For L – N With Built In Fuse To Avoid Any External Fuse In Case Of Load Current Is More Than Specified Limit Of Spd Spd According To En 61643-11 / Iec 61643-11: Type 1 / Class I Maximum Continuous Operating Voltage ( A.C. ) ( Uc ) :255 V ( 50 / 60 Hz ) Nominal Voltage ( A.C. ) ( Un ) : 230 V ( 50 / 60 Hz ) Lightning Impulse Current ( 10 / 350 Μs ) ( Iimp ) : 25 Ka Voltage Protection Level ( Up ) : = 1.5 Kv Response Time ( Ta ) : = 100 Ns Max. Mains-Side Overcurrent Protection: Not Required Rated Breaking Capacity Of The Internalbackup Protection:100 Ka Temporary Overvoltage ( Tov ) ( Ut ) – Characteristic: 440 V / 120 Min. – Withstand Operating State: Mechanical, Fault Indication Green / Red There Should Be Potential Free Contact For Remote Signalling Approvals: Kema / Vde / Ul / Nabl 53 Short Text : Type 1+2 Spd N-Pelong Text :Supply And Installation Of Spark Gap Based Metal Encapsulated Lightning Current & Surge Protection Device At Mains Lt Panel For N -Pe Spd According To En 61643-11 / Iec 61643-11: Type 1 / Class I Maximum Continuous Operating Voltage ( A.C. ) ( Uc ) :255 V ( 50 / 60 Hz ) Lightning Impulse Current ( 10 / 350 Μs ) ( Iimp ) : 100 Ka Voltage Protection Level ( Up ) : = 1.5 Kv Response Time ( Ta ) : = 100 Ns Temporary Overvoltage ( Tov ) ( Ut ) – Characteristic: 1200 V / 200 Ms – Withstand Operating State: Mechanical, Fault Indication Green / Red There Should Be Potential Free Contact For Remote Signalling Approvals: Kema / Vde / Ul / Nabl 54 Short Text : Isolating Spark Gaplong Text :Supply And Installation Of Isolating Spark Gap With Connecting Cables To Equipotentialize Different Earth Grids Isolating Spark Gap According To Iec 62305-3, Particularly For Use In Potentially Explosive Atmospheres Up To Zone 1 / 21, With Connecting Cables For Aboveground And Underground Installation Approvals: Iecex / Atex Certification ( 94 / 9 / Ec ) / Peso Ex Marking According To Iec / En 60079: Gas Ii 2G Ex D Iic T6 Iec / En 61241: Dust Ii 2D Ex Td A21 Ip67 T 80°C Lightning Impulse Current ( 10 / 350 ) : 100 Ka Class Of Lightning Current Carrying Capability Acc. To Iec 62561-3:2011 ( 81 / 387 / Cdv ) / En 62561-3: Hrated Impulse Sparkover Voltage ( With Pre-Wired ) : <= 1.25 Kv Degree Of Protection: Ip 67 Pre-Wired Cable Size: 1X25 Sqmm. Of 2 Mtr. Long On Either End

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 08-08-2022 ADDENDUM Other 26-08-2022
2 20-08-2022 Corrigendum Other 26-08-2022
3 25-08-2022 Clarification-1 Other 26-08-2022

Key Value

Document Fees
Refer document
EMD
INR 407000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail