Electrical Renovation Work At Boys Hostel Andclass Room Of A.B.N. Seal College , Cooch Behar.- 1 Supply & Delivery Single Led Fl Fittings ( Make-Philips, Cat No - Tmc50 1P 1Xt Led 22W P3241 / Crompton - Eco-I - Igp161lt8-16 Or Its Equivalent Of Osram / Wipro ) 2 Supply & Delivery Twin Led Fl Fittings ( Make-Philips, Cat No - Tmc50 1P 2Xt Led 22W P3242 / Crompton - Eco-I - Igp162lt8-16 Or Its Equivalent Of Osram / Wipro ) 3 Supply & Delivarysingle 18W Led Light Tube ( Make- Philips- Mas Led 1200Mm 18W865t8 I - 2100Lm / Crompton- Ultron Plus - Lt8-18-865- ( 3 ) Or Its Equivalent Of Osram, Wipro ) 4 Fixing Only Single / Twin Florescent Light Fitting Complete With All Accessories Directly On Wall / Ceiling With Hw Block And Suitable Size Ms Fastener, Ceiling Plate, Nipples Etc. As Required As Per Gs ( P-C-2 / 14D ) 5 Supply & Delivery Of 240 V 1200 Mm Ceiling Fan Incl. All Accessories, As Per Direction Of Eic ( Make- Orient -Summer Cool / Orient -Newbreeze / Crompton- Hs Decora ) 6 Fixing Only Ceiling Fan Complete With Blade, Canopy, Fork, Rubber Bush Etc. Incl. S&F Connecting Wire For Down Rod Upto 30Cm Incl.Painting The Rod With Approved Paint And Making Necessary Connection As Required By 2X1.5Sqmm Flexible Copper Wire 7 Supplying & Fixing Ms Fan Clam Of Two Piece Type For Rc Ceiling As Per Approved Specification, Fabricated From 40 Mm X 9 Mm Ms Flat Including Making Good Damages To Building Roof With Satisfactory Finishing And Painting – ( As Per Drawing No. 475 Of Pwd Specification Book – May 1991 ) 8 Extra For Supplying Additional Wire For Down Rod ( For Fan ) & Painting The Rod Exceeding 30 Cm By 2X1.5 Sqmm Flexible Copper Wire 9 Supply & Fixing Socket Type Fan Regulator ( Step Type ) ( Model Anchor ) On Existing Sheet Metal Switch Board With Bakelite / Perspex Top Cover By Screw After Making Housing For Regulator Knob By Cutting Bakelite / Perspex Top Cover Incl. Making Necy. Connections Etc. 10 Supplying& Fixingexhaust Fan Of Below Mentioned Sweep Including Sdupply &Fixing , Suitable Sized Louver Shutter / Cowl On Wall With Necy Bolts & Nuuts After Msking Hole In Wall And Msking Good Damages And Smooth Cement Finish Etc As Practicable As Possible And Providing Necy . Lenth Of Pvc Insulated Wire And Making Connection Etc ( Make-Epc Heavy Duty / Marathon ) -- 230V, 1370Rpm , 40W , 9 Sweep 11 230V, 1420Rpm , 80W , 12 Sweep 12 Supply & Fixing , 250V, 9W Led Bulb B22 White ( Make - Philips Model - Ace Saver / Crompton- Led 9W - B22 / E27 - Cdl / Ww Or Equivalent Model Of Osram / Wipro ) 13 Supply And Fixing Angular Batten Holder ( Anchor ) On 75Mm Dia Pvc Round Block / Round Bakelite On Wall / Ceiling As Per Gs 14 Distribution Wiring In 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire ( Make Havells / Finolex / Polycab / Kei ) In 20Mm Size Pvc Rigid Conduit Fr Hms / Mms Type [ Make Precision / Polycab ] Incl. Necy. Fittings As Required.2 X 36 / 0.3 ( 2.5 Sqmm ) + 1 X 22 / 0.3 ( 1.5 Sqmm ) Ecc 15 2 X 22 / 0.3 ( 1.5 Sqmm ) + 1 X 22 / 0.3 ( 1.5 Sqmm ) Ecc 16 Finishing Of The Pvc Insulated Wire Ends By Socketting With Pin / Ring Type Copper Sockets And Insulated Tapes Etc., Including Supplying Sockets, Tapes.2X2.5Sqmm +1X 1.5Sqmm 17 2X1.5Sqmm +1X1.5Sqmm 18 Distribution Wiring In 1.1 Kv Grade 2X22 / 0.3 ( 1.5 Sqmm ) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire ( Make-Polycab / Havells / Finolex / Kei ) Partly In 20Mm Size Pvc Rigid Conduit `Fr` Hms / Mms Type [ Make Precision / Polycab ] [ For Ceiling Portion Only ] And In 19Mm Bore, 3Mm Thick Polythene Pipe [ For Horizontal & Vertical Run Embedded In Wall ] , With 1X22 / 0.3 ( 1.5 Sqmm ) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire For Ecc, To Light / Fan / Call Bell Points With Piano Key Type Switch Fixed On Ms Crc Sheet Metal ( 16 Swg ) Switch Board On Wall Complete With 2 No. “Ph & N” Copper Bar Incl. Bakelite / Perspex Top Cover 3 Mm Thick And Incl. 175 X 100 X 65Mm Inspection Box, Making Earthing Attachment, Painting The Ms Box And Mending Good The Damages To Original Finish [ Only Pvc Rigid Conduit On Ceiling And Remaining Portion Concealed ] ( Av. Run 10Mts ) . 19 Distribution Wiring In 1.1Kv Grade2x22 / 0.3 ( 1.5Sqmm ) Single Core Stranded `Fr` Pvc Insulated And Unsheathed Copper Wire In 20Mm Size Pvc Rigid Conduit `Fr` Hms / Mms Type [ Make Precision / Polycab ] On Wall, Ceiling With Saddles And Other Accessories With 1.1Kvgrade 1X22 / 0.3 ( 1.5Sqmm ) Single Core Stranded `Fr` Pvc Insulated & Unsheathed Copper Wire ( Make-Polycab / Havells / Finolex / Kei ) For Ecc To 5A 3Pin Flush Type Plug Socket & Piano Key Type Switch Fixed On Ms Crc Sheet Metal ( 16G ) Switch Board Cum Jb On Wall Incl. Bakelite Top Cover 3Mm Thick And Incl. Painting The Ms Box And Mending Good The Damages ( On Board ) . 20 Supply& Fixing240v, 03Nos, 6Amp. Plug Socket With 6Amp Piano Key Type Switch And 01No, 20Amp. Plug Socket With Piano Key Type Switch With Indication Lamp & 16A Kit-Kat Flash Type Fuse ( Make-Anchor ) On Sheet Metal Switch Board Embedded In Wall Incl. S & F 250X200x65 Mm Sheet Metal ( 16Swg ) Box With 3Mm Thick Bakelite Top Cover Incl. Earthing Attachment After Cutting The Wall And Making Necessary Connection As Required. 21 Supply & Fixing250 V 15 A Piano Key Type Switch & Socket ( Approved Make ) On Existing Sheet Metal Inspection Boxetc.As Per G.S [ 14 ( B ) & 15 ( B ) / E-5 ] 22 Sitc , Led Street Light Fitting Having System Lumen Efficacy 120 Lm / W Suitable For Use With 230 Volt 50 Hz A.C. Supply Etc. As Required. ( Make- Philips -Brp062 Led 80 Cw Slc A1 S1 Psu Or Crompton - Lst-70-Cdl-M Or Equivalent Make Of Osram / Wipro ) On The Existing Gi Pipe & Connection. 23 Fixing Outdoor Type Fluorescent / Sv / Mv Light Fitting On Pole Including S&F 40 Mm Dia X 1.68 Mts. Long Gi Pipe ( Isi-Medium ) Bracket With 40 Mmx10 Mm Thick, Ms Clamp Etc. And Providing Wiring With 2X1 / 1.40 Pvc Insulated And Sheathed Wire ( Single Core ) From Loop Box At The Base Of Pole To Light Fiting Through Pole & Bracket ( Without Control Switch ) Including Making Connections & Painting. 24 Sitc , 120 Watt Led Floodluminaire Fitting Having Made Up Of Pressure Die Cast Aluminum Housing With Toughened Glass And High Power Leds And Secondary Lenses With Ip66 Protection. System Efficacy = 110 / 125Lpw Suitable For Use With 230 Volt 50 Hz A.C. Supply Etc. As Required. ( Make: Jaquar, Model- Luxor, Cat: Lxrflds140xc Or Its Equivalent Of Philips - Bvp192 Led132 Cw Nb Fg A1 Gr Psu / Crompton - Pluto Neo - Lfln-120-Ww / 60-M Or Equivalent Make Of Osram / Wipro ) 25 Fixing Only Floodlight Fittings On Top Of Masonary Structure By 3 Nos. 10 Mm Dia X 87 Mm Long Rag Bolts, Nuts & Double Washers Complete Either 37 Mm X 10 Mm Ms Flat Support / Or By Other Means As Required 26 Earthing With 50 Mm Dia Gi Pipe 3.64 Mm Thick X 3.04 Mts. Long And 1 X 4 Swg Gi ( Hot Dip ) Wire ( 4 Mts. Long ) , 13 Mm Dia X 80 Mm Long Gi Bolts, Double Nuts, Double Washers Incl. S & F 15 Mm Dia Gi Pipe Protection ( 1 Mts. Long ) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level Driven To An Average Depth Of 3.65 Mts. Below The Ground Level As Below ---- By Isi-Medium Gi Pipe 27 Excavation Of Soil For Installation Of Earth Electrode And Filling &Ramming For Soft Soil. 28 Connecting The Equipments To Earth Busbar Including S & F 6 Swg Gi ( Hot Dip ) Wire Of Size As Below On Wall / Floor With Staples Buried Inside Wall / Floor As Required And Making Connection To Equipments With Bolts, Nuts, Washers, Cable Lugs Etc. As Required And Mending Good Damages 29 Supplying & Fixing Earth Busbar Of Galvanized ( Hot Dip ) Ms Flat 25 Mm X 6 Mm On Wall Having Clearance Of 6 Mm From Wall Includingproviding Drilled Holes On The Busbar Complete With Gi Bolts, Nuts, Washers, Spacing Insulators Etc. As Required 30 Supply & Delivery Ofhotdip Galvanised ( As Per Is:2629 / Is 2633 / Is 4759 And With Its Latest Amendment ) Octagonal Pole Made Ofht Steel ( Sheet Thickness -3Mm ) Conforming Tograde S355 Of Bsen 10025 Along With Welded Base Plate Of Required Sizeconforming To Is: 226 / 2062With Integrated Control Box With Required Sizes Studs For Termination Of 2 Core 10 / 4 Core 16 Sq Mmal ( Armoured ) Cable Including S&F1 No6 Amp Sp Mcb ( C-Series ) For Each Out Going Circuit To The Fittings With Proper Pad Locking Arrangement For The Followingpole-- 7 Mtr Long [ Top Dia ( A / F ) - 70 Mm, Bottom Dia ( A / F ) -130 Mm ] Base Plate Size : 200 Mm X 200Mm X 12 Mm.. ( Make :Bajaj / Philips / Valmont / Cg / Transrail / Bansal ) .Erection Of The Following Octagonal Pole Bydesigning And Castingrcc ( M 20 ) Foundation Ofsuitable Size As Specified Belowconsidering The Safe Soil Bearing Capacity At Site As T / Sq M, Includingexcavation Of Earth, Providing, Cutting, Bending And Placing In Position Reinforcement As Per Drawing And Providing Pipe For Cable Entry And Exit As Required And Providing And Fixing Of 4 Nos.Foundation Bolts ( J Type ) As Specified Belowand As Per Drawing On Ground Surface Including Back Filling And Cleaning Extra Earth -7 Mtr Long [ Foundation Size - 500 Mm X 500 Mm X 1200 Mm, J Bolt Size - M 20 X 600 ] 31 S & F 24” Dia Circular Shape Structure Made By 25 Mm Dia ( Isi-M ) Gi Pipe On Pole Cap By Welding Incl. Providing Support At Four Corner By 4 Nos. 20 Long 40Mm Dia Gi Pipe And Making Suitable Size Hole On Gi Pipe For Nut, Bolt Etc. Incl. Painting, Incl. S&F Pole Cap ( 80Mm Dia 10 Long ) As Per Direction Of E.I.C. 32 Supply Of4 / 3.5 Core Xlpeinsulated & Sheathed Armoured Aluminium Conductor Cables For Working Voltage Up To 1100 Volts Of Following Sizes [ Make: Polycab / Havells / Rr Kable / Kei ] 4 Core 95 Sq.Mm [ For Vtpn Charge ] 33 Supplying And Fixing Compression Type Gland And Finishing Thoseforfollowing Xlpe / Pvc Armoured Cable ( 2 / 4 / 3.5 ) Core As Per Gs. -- 4 Core 95 Sq.Mm 34 Laying Of Cable As Below, After Cutting Floor / Pavement / Wall / And Making Holes Incl., Embedding The Cable At An Average Depth As Below And Mending Good The Damages To Original Finish Incl. Removing The Rubbish -- From 35 Sqmm To 95 Sqmm At An Average Depth Of 75 Mm In Floor / Pavement / Wall Etc. [ 5 ( I ) / F- 3 ] 35 Supplying And Fixing 415V, 160A, Tpn Sfu With Ss Enclosure On Flat Iron / Angle Iron Frame On Wall With Nuts Bolts Etc Incl. S & F 3 Nos. Din Type Hrc Fuse As Per Rating. [ Make: L & T / Siemens / Schneider ] 36 Supplying And Fixing 415V, 160A, Tpn Changeover Switch With Sheet Steel Enclosure On Angle Iron Frame On Wall With Nuts Bolts Etc [ Make: L & T / Siemens / Schneider ] 37 Supplying And Fixing 8 Way Double Door Vertical Tpn Mcb Distribution Board ( Upto 160A ) For Mccb Incomer With Ip-42 / 43 Protection, On Angle Iron Frame On Wall & Mending Good The Damages To Original Finish Incl. Inter Connection With Suitable Size Of Copper Wire And Neutral Link & Provision For Earthing Attachment With S&F 4 Pole 160A Mccb Of Breaking Capacity 25Ka / 35Ka As Incoming And 4 Nos. 415V 40A Tp Mcb & 4 Nos. 415V 63A Tp Mcbof Breaking Capacity 10Ka And C Characteristics As Outgoing ( Make: Legrand / Schneider / Siemens ) 38 Supplying And Fixing Double Door Horizontal 4 Way Tpn Mcb Distribution Board With Ip-42 / 43 Protection, On Surface Of Wall By Clamp Arrangement & Mending Good The Damages To Original Finish Incl. Cable End Box And Inter Connection With Suitable Size Of Copper Wire And Neutral Link & Provision For Earthing Attachment A ) Enclosure -01No, B ) 32Amp Spmcb -12Nos, 63Amp Isolator-01No ( Make-Legrand / Schneider / Siemens ) . 39 Supply & Fixing 250 Volt 6 - 10 Amp. 2 + 10 Way Spn Mcb Db With Ss Enclosure ( 8Gb0208 ) With Ip-42 / 43 Protection With 40 Amp. Dp Isolater As Incomer And 10 Nos. Sp Mcb ( C Curve, 10 Ka ) As Outgoing Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Inter Connection With Suitable Size Cu. Wire And Neutral Link& Provision For Earthing Attachment As To G.S. ( Make-Legrand / Schneider / Siemens ) . 40 Supply & Fixing 240 V, 4 Nos. 6A, Plug Socket With Separate 4Nos. 6 A Piano Key Type Switch, Indicator & 16A Kit-Kat Flush Type Fuse ( Brand Approved By Eic ) On Sheet Metal Switch Board Embedded In Wall Incl. S & F 240X200x65mm Ms ( 16Swg ) Switch Board And Bakelite / Perspex Top Cover Of 3Mm Thick By Brass Screws After Making Housing For Switch By Cutting Bakelite / Perspex Cover And Making Necessary Connections As Required