| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form work for : Columns, piers, abutments, pillars, posts and struts |
| 4 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 5 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 13 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm |
| 14 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 15 | Providing and fixing cramps of required size & shape in RCC/ CC / Brick masonry backing with cement mortar 1:2 ( 1 cement : 2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). Stainless steel cramps |
| 16 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Wedge expansion type Fastener with threaded dia 10 mm |
| 17 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 18 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm |
| 19 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm |
| 20 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper |
| 21 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 22 | Providing and fixing to existing door frames. 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
| 23 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 24 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 25 | Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. |
| 26 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement |
| 27 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 28 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 29 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 30 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 31 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 33 | Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in- charge (payment for providing grooves shall be made separately). |
| 34 | Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in- Charge. |
| 35 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 36 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) |
| 37 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 38 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : Old work (one or more coats) |
| 39 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
| 40 | Finishing walls with Acrylic Smooth exterior paint of required shade: Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 41 | DismantlingW.C.Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. |
| 42 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 43 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 44 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): From brick work in cement mortar |
| 45 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below |
| 46 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. |
| 47 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 48 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 49 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 50 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 51 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron \"Y\" shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 52 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in- charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). |
| 53 | Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50m x 2.00m made of 40 x 40 x 6 mm angle iron or 50 x 50 x 3 mm hollow MS tube posts/ horizontal members/ bracings covered with 1.63 mm thick MS sheet. The sheet shall be fixed with 30 x 5 mm MS flat by suitable welding/ riveting. The panels shall be made so that gap of 50 cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/ m, 50 cm long shall be provided as the bottom having oval shaped holes of size 50 x 25 mm at both ends with 50 cm long MS angle 40 x 40 x 6 mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250 mm long expansion fasteners at both ends. The work shall be executed as per drawing/ direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in- Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion.Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting.The barricading provided shall remain to be the property of the contractor on completion of the work). |
| 54 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 55 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer- in-charge. (Old CC paver blocks shall be supplied by the department free of cost). |
| 56 | Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer\"s specifications & direction of Engineer- in-Charge. 60mm thick Cement concrete paver block of M-35 grade with approvedcolour, design & pattern. |
| 57 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 58 | Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling ofstandard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. |
| 59 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. ofquality and make as approved by Engineer - in - charge. |
| 60 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia |
| 61 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes |
| 62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes |
| 63 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 64 | Providing and fixing PTMT bib cock of approved quality and colour. 15 mm nominal bore, 122mm long, weighing not less than 99 gms |
| 65 | Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia |
| 66 | Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms |
| 67 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer- in-charge. |
| 68 | Brick work with F.P.S. bricks of class desgn 75 in foundation and plinth in C.M 1:4(1 Cement:4 course sand) ( old FPS bricks shall be suppled by the deppt. free of cost) |
| 69 | Providing & fixing transparent acrylic sheet 4mm thick in steel window with putty and nails wherever necessary required as per direction of Engineer-in-charge. |
| 70 | Providing and laying Vitrified tiles in different size (thickness to be specified by the manufacturer). With water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick ser tile adhesive (water based) conforming to IS : 15477, in average 6mm thickness, including grouting of joints (Payment for grouting of of joints to be made separately). size of tile 600x600 mm |
| 71 | Providing and laying ceramic glazed wall tiles of size minimum size 300 x 600 mm conforming to IS : 15622 (thickness to be specified by the manufacture) Digital series of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 Cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 72 | Extra for cutting existing kota stone floor in corridors for provision of tactiles (excluding joint lines in stones) complete as per direction of engineer-in-charge. |
| 73 | Extra for using marble stone chips in place of grit stone in grit plaster |
| 74 | Granite work gang saw cut (polished and machine cut) of thickness 16mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand)with an admixture of pigment to match the marble shade: (To be secured to the backing by means of cramps, which shall be paid for separately). Area of slab over 0.50 sqm |
| 75 | Providing and laying ceramic glazed wall tiles of size minimum size 600x600mm conforming to IS : 15622 (thickness to be specified by the manufacture) Digital series of approved make in all colours, shedes except burgundy, bottle greenblack of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement mixed with pigment of matching shade complete. |
| 76 | Total |
| 77 | Add Cost Index 21.46% |
| 78 | Total |
| 79 | Less 9.50% as per Delhi Govt. Circular |
| 80 | Total |
| 81 | Providing and laying cement concrete (M30 grade) tactile tile such as directional, warning or hazardous (for vision impaired persons as per standards) of size 300x300x60 mm {60 mm base + (5mm ± 0.5mm) thick raised portion}having water absorption = 6% and conforming to IS: 13801, of approved make in all colours (preferably yellow) and shades for footpath laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. (The thickness of wearing layer should not be less than 8mm) and as per harmonized guidelines and space standards for barrier free built environments for persons with disability and elderly persons issued by Ministry of Urban Development, Govt. of India complete as per direction of Engineer-in-Charge. |
| 82 | Providing and fixing Building Entrance signage/Tactile Layout/Emergency Evacuation Layout on the wall or with any other required structure, with provision of multilingual text integral with 4mm thick blue Acrylic base plate with min 0.5 mm Alluminium sheet at the back with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm, raised above base plate by not less than 0.8mm and the equivalent word/s written in Hindi/any language as required with same specifications with Grade 1 Braille to be integral with the sign face and should be raised 0.5mm above Acrylic base plate. Each signboard to be fixed strictly as per the Harmonised Guidelines & Space Standards for Barrier Free Built Environment for persons with Disability, issued By MOUD, Govt. of India, and as as per approved drawings and complete as per the directions of Engineer-In-Charge.(Note:- i). Payment for structure, if required, shall be paid separately.)ii) Size of the Signboards shall be proportional to the layout plan of the particular building, Min Size of the above signboards shall not be less than 1200mm X 750 mm. |
| 83 | Providing and fixing signages on the wall or with any other required structure, with provision of multilingual text integral with 4mm thick blue Acrylic base plate with min 0.5 mm Alluminium sheet at the back with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm, raised above base plate by not less than 0.8mm and the equivalent word/s written in Hindi/any language as required with same specifications with Grade 1 Braille to be integral with the sign face and should be raised 0.5mm above Acrylic base plate. Each signboard to be fixed strictly as per the Harmonised Guidelines & Space Standards for Barrier Free Built Environment for persons with Disability, issued By MOUD, Govt. of India, and as as per approved drawings and complete as per the directions of Engineer-In-Charge. Note:- i). Payment for structure, if required, shall be paid separately.)ii) The Above Nomenclature shall be applicable for all types of signgaes like a) Identification signgaes (For Eg Room Names/Toilet facility/Drinking Water/Staircase /Entry/Exit/Lift etc.) of the size 150 mmX230 mm or 200X200 mm).b) Floor Directories ( Signboard Placed near the Lift/ Staircase / Entry to the particular Floor indicating the facilities on that floor. These are normally also callled as Directional Signages.). Min Size of these Boards shall not be less that 450 mmX450 mm. c) Emergency Exit Sign Boards (Generally used Text as \"In Case of Emergency, Do Not Use The Lift\" ,\"Emegency Exit\" etc.) |
| 84 | Providing and fixing 50 mm wide Yellow colour, self addhesive \"EDGE STRIPS\" of approved make on risers of staircase to help persons with visual diabilities and elederly including cutting and pasting complete in all respect as per direction of Engineer-in-charge. |
| 85 | Providing and fixing 25 mm wide high intensity Anti-Skid reflective tape of approved make on edges of treads of staircase including cutting, pasting etc. complete in all respect and as per direction of Engineer-in-charge |
| 86 | Providing and fixing Stainless Steel (Grade 304) Braille Labels of size 170mm x 35mm X 0.5 mm having Braille dots raised 0.5mm above base platewith one SS rivet of same grade and adhesive of approved makeon handrails, complete as per the directions of the engineer in charge |
| 87 | Providing and fixing in position \"U\" shapedGrab Bar made up of Heavy Duty stainless steel (grade 304) of 750 mm in length & 40 mm dia (Outer dia with 3 mm thick sheet ) seamless pipeincluding Hinge,base plate and steel fastners, in the toilets as per manufacturers specification, as per drawings and \"Harmonised Guidelines & Space Standard for Barrier Free Environment issued by MOUD, Govt Of India\" to make them Accessible for Persons with Disabilities. Rate shall include all accessories, labour and material, complete as per direction of Engineer-in-charge. |
| 88 | Providing and fixing in position \"L\" shapedGrab Bar made up of Heavy Duty stainless steel (grade 304) 40 mm (Outer dia with 3 mm thick sheet ) diaseamless pipe, & 750 mm in vertical length& 900 mm in horizontallengthincluding base plate andsteel fastners in the toilets as per manufacturers specification complete as per drawings and \"\"Harmonised Guidelines & Space Standard for Barrier Free Environment issued by MOUD, Govt Of India\" to make them Accessible for Persons with Disabilities. Rate shall include all accessories, labour and material, complete as per direction of Engineer-in-charge |
| 89 | Providing and fixing coloured, preferably yellow PU - Tactile Strips (Guiding ) with 3 stems having stem dia of 6.0 mm & stem length between 20-25 mm, as ground surface indicators for the visually impaired persons on the pedestrian pathway as per manufacturers design / specification and as per harmonised guidelines complete in all respect and as per direction of Engineer-in-Charge. |
| 90 | Providing and fixing coloured, preferably yellow PU - Tactile Studs (Warning / Positional ) with 1 stems having stem dia of 6.0 mm & stem length between 20-25 mm, as ground surface indicators for the visually impaired persons on the pedestrian pathway as per manufacturers design / specification and as per harmonised guidelines complete in all respect and as per direction of Engineer-in-Charge. |
| 91 | Credit for old Steelfrom dismantling |