Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments And Construction Of Pump House / Panel Room / Operator Room At Various Water Supply Schemes Of Qazigund Sub Division Of Jal Shakti ( Phe ) Mechanical Division South Awantipora.- 1 01.Wss Imp. Turku Tachloo ( Adv. Cost: Rs. 12, 08, 871 / - ) 2 Supply, Installation, Testing & Commissioning Of Submersible Horizontal Monoset Pumping Unit For Raw Water Of River As Per Is 8034 With Following Specification Are As Under :Pump : Discharge: 10000 Gph At 19 Mts Headefficiency= Not Less Than 50% Speed= 2900 Rpmtype Of Pump = Mixed Flow.Type Of Fluid To Be Handled=Clear Watermaterial Of Construction:Impeller = Stainless Steel Pump Shaft = Stainless Steel Ss 410.Pump Casing = Cast Iron / Stainless Steelimpeller:Impeller Is Of The Enclosed Or Semi – Enclosed Type And Properly Balanced.Enclosed Impellers Equipped With Seal Rings On Their Hubs.Coupling:A Suitable Coupling Arrangement Provided With Pump Set.Non Return Valve:-Non Return Valve Of The Suitable Size Provided Above The Pump Discharge Case.Motor:-Method Ofstarting = Star – Delta Speed = 3000 ( Sync ) .Frequency= 50 ± 3 % Hz Working Voltage = 380-415 ± 15% V, 03 Phaseefficiency = Not Less Than 90% Rating= Not Less Than 5 Hpclass Of Insulation =F / Suitable For Above Parameterssubmersible Motor Should Be Water Filled Water Lubricated Squirrel Cage Type Having Capacity For Above Pumping Parameters And Working On 3 Phase; Ac Supply Ranging From 380 To 415 Volts, 50Hz. The Motor Should Be Sealed By Radial Rings To Avoid Mixing Of Well Water With Motor Filled Water.A ) The Job Includes Providing And Fitting Of Interlocking Arrangement Against Any Failure Of Coupling. It Must Be Fabricated Out Of Ms Strips Of Suitable Size And Length.B ) The Job Includes Providing And Fitting Of Appropriate Size Ms Nipple 2 Feet Long Threaded On One End And Welded To Same Size Ms Flange Ofthickness ( As Per Table-17 ) At Other End For 80 Mm Diameter Column Pipe As Per Site Requirement. The Threaded Portion Should Be As Per Size Of Pumping Out Let For Proper Fixing.The Job Includes Providing And Fitting Of R. I. Cloth Joints / Rubber Washers With Nuts, Bolts And Washers For All Joints Of Column Pipe. The Job Also Includes Lowering Of Pumping Unit In The Well Then Proper Testing And Commissioning Of Pumping Unit On Full Load At Site.Note: Providing Of Test Certificate & Characteristic Curve Of Pumping Equipment Is Compulsory And Pumping Unit Is To Be Approved From The Concerned Sub Divisional Office Before Procuring. 3 Supply, Installation, Testing & Commissioning Of Submersible Horizontal Monoset Pumping Unit For Pst / Sump To Liftwater Through Pressure Filterplant Upto Oht As Per Is 8034 With Following Specification Are As Under :Pump : Discharge: 10000 Gph At 45 Mts Headefficiency= Not Less Than 50% Speed= 2900 Rpmtype Of Pump = Mixed Flow.Type Of Fluid To Be Handled=Clear Watermaterial Of Construction:Impeller = Stainless Steel Pump Shaft = Stainless Steel Ss 410.Pump Casing = Cast Iron / Stainless Steelimpeller:Impeller Is Of The Enclosed Or Semi – Enclosed Type And Properly Balanced.Enclosed Impellers Equipped With Seal Rings On Their Hubs.Coupling:A Suitable Coupling Arrangement Provided With Pump Set.Non Return Valve:-Non Return Valve Of The Suitable Size Provided Above The Pump Discharge Case.Motor:-Method Ofstarting = Star – Delta Speed = 3000 ( Sync ) .Frequency= 50 ± 3 % Hz Working Voltage = 380-415 ± 15% V, 03 Phaseefficiency = Not Less Than 90% Rating= Not Less Than 15 Hpclass Of Insulation =F / Suitable For Above Parameterssubmersible Motor Should Be Water Filled Water Lubricated Squirrel Cage Type Having Capacity For Above Pumping Parameters And Working On 3 Phase; Ac Supply Ranging From 380 To 415 Volts, 50Hz. The Motor Should Be Sealed By Radial Rings To Avoid Mixing Of Well Water With Motor Filled Water.A ) The Job Includes Providing And Fitting Of Interlocking Arrangement Against Any Failure Of Coupling. It Must Be Fabricated Out Of Ms Strips Of Suitable Size And Length.B ) The Job Includes Providing And Fitting Of Appropriate Size Ms Nipple 2 Feet Long Threaded On One End And Welded To Same Size Ms Flange Ofthickness ( As Per Table-17 ) At Other End For 80 Mm Diameter Column Pipe As Per Site Requirement. The Threaded Portion Should Be As Per Size Of Pumping Out Let For Proper Fixing.The Job Includes Providing And Fitting Of R. I. Cloth Joints / Rubber Washers With Nuts, Bolts And Washers For All Joints Of Column Pipe. The Job Also Includes Lowering Of Pumping Unit In The Well Then Proper Testing And Commissioning Of Pumping Unit On Full Load At Site.Note: Providing Of Test Certificate & Characteristic Curve Of Pumping Equipment Is Compulsory And Pumping Unit Is To Be Approved From The Concerned Sub Divisional Office Before Procuring. 4 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units.The Body And Bonnent Of The Valve Shall Be Of Ductile Iron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valve Shall Be Compatible For Buried Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positions Rest Specification As Per Cluase 12 Of Sbd. 5 Providing And Fitting Of 100 Mm Dia Ductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approved For Drinking Water ) .Rest Specification As Per Cluase 13 Of Sbd. 6 Fabrication, Providing And Fitting Of 100Mm Dia Washout Tee / Y Junctionwith Arm Length 1.2 Feet Each. The Tee Shall Be Fabricated Out Of G.I C-Class Pipe With M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends. 7 Fabrication, Providing And Fitting Of Modular Motor Control Panel Of Appropriate Size Fabricatedout Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted Withaccessoriesmu-G 10 Rest Specification As Per Cluase 43 ____ Of Sbd. 8 Providing, Fitting, Testing And Commissioning Of Voltage Stabilizer As Per Specifications Below:Type Of Voltage Controller: Manually Operated Copper Wound, 3-Phase, Ac Power Supply Multistep.Type Of Regulator : Double Plate Type With Electrolytic Copper Contacts.Input Voltage : 250-400 Volts. ( 3 Phase ) Output Voltage : 400 ±10% Volts.Frequency : 50 ±3 C / S.Windings : Electrolytic Grade Copper Of Adequate Section, Vacuum Impregnated And Rest Specification As Per Cluase 44 Of Sbd.Rating: 50 Kva 9 Providing And Fitting Of 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. The Main Specification Of The Cable Is Given Below: Rest Specification As Per Cluase 47 Of Sbd.Size: 10 Sqmm 10 P / I Of Earthing Station For Electric Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards.Safe Earthing Electrode Size : 80 Mm Dia , Length : 2000 Mmback Fill Compound : 30 Kg 11 Supply, Installation, Testing & Commissioning Of 1000 Va Full Sine Wave Power Inverter ( Make: Reputed ) Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover. ( Make: Reputed ) With 2-Core 6Mm2 Cu Wiring As Per Site Requirement Along With Other Accessories Like Ss-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 12 Tool Kit For Maintenance: -The Tool Kit For Maintenance Shall Comprise Of The Following And All The Items As Mentioned Belowshall Be Of Providing Of Tool Kit Consists Of Following Itemsi. Double Ended Spanner ( Chrome Plated ) 02 Sets Complete Ii. Double Ended Ring Spanners Chrome Plated 02 Sets Completeiii. Allen Key Set Black Finish 02 Sets Complete Iv. Combination Pliers Insulated With Thick C.A Sleeve; Size In Mm 165, 210, 255 Each – 02 No. V. Long Nose Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205 Each – 02 No.Vi. Side Cutting Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205 Make – 02 No.Vii. Insulated Screw Driversblade Length In Mm Blade Dia. In Mm Tip Dimensions In Mm Quantity50 3 1.6 X 0.4 02 75 3 1.6 X0.4 02 100 3 3 X 0.4 02125 3.5 3.5 X 0.5 02150 3.5 3.5 X 0.5 02 200 4 4 X 0.6 02 300 5 5 X 0.8 02Viii. Hammer With Handle Weight – 110 Mg, 340 Gm , 600 Gm –Each – 1No. Ix. Heavy Duty Pipe Wrench Length In Mm - 200, 300, 600 Each – 01 No.X. Electric Multimeter=1No Xi. Digital Multimeter – 1No.Xii. Digital Clamp Tester Capable To Measure Up To 400A - 1 No. Xiii. Hack Saw Frame With Hack Saw Blade – 01 No.Xiv. S-16 Mxl, S- 16 H X L Socket Set ( 19 Sockets + 6 Accessories ) – 01 No. 13 Fabricationof6’ X 6’ Angle Iron Bed By Way Of Providingand Fitting Of Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 14 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 Nos Including Cutting, Fixingall Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 15 Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’S Iv ) Single Bed Warm Blankets With One Sided Fur- 02 No’S The Filling Material For Mattress, Quilt And Pillow Shall Be Of Good Quality Cottonb ) The Job Also Includes Providing Of Pressure Cooker 5Ltr 02 No’S, Steel Patella ( Utensil ) 5Ltrs 02 No’S, Cooking Heater 01 No., Room Heater 01 No., Steel Buckets 10 Litre Capacity 01 No., Plastic Bucket 10 Litre Capacity With Mug 02 No’S Each, Steel Glasses 06 No’S, Steel Plates With Large Spoons And Bowls 03 No’S Each, Cup And Saucer Set ( 01 No. Set ) And, 5Kg Gas Cylinder With Burner / Stove. The Job Also Includes Providing Of Thermo-Cool 15’X12’ Along With Excel Matting Of 15’X12’ Size. The Job Also Includes Providing Of Unbreakable Plastic Chair Table Set Consisting Of Chairs 04 No’S, Extra Heavy Table 01 No. The Job Also Includes Providing Of Good Quality Safety Door Locks ( 03 No’S ) Of Godrej, Link Locks 16 Providing & Fitting Of Lighting Points In 1.5 Mm Sq. Multi Strand Pvc Wire As Conductor To Be Laid / Carried In Pvc Channel / Conduit As Per Site Requirement. The Job Also Includes Providing And Fitting Of 5 Amp. Switch Button / Angle Holders To Be Fitted With 15 Watt Ledinside The Pump House. 17 Providing & Fitting Of Heating Points In 2.5 Sq. Multi Stand Conductor To Be Laid & Carried In Pvc Channel / Conduit As Per Site Requirement. The Job Includes Providing And Fitting Of 16 Amp. Switch Socket Combine 18 Providing And Fitting Of 18 Sweep Seiling Fan Of Standard Make Including The Cost Of All Cables , Connections , , Controlsystem Along With The Speed Regulator With Control Switches For The Power Supply 19 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply. 20 Providing Of Bamboo Ladders 18 Feet Long Along With 15 Feet Long Link Rods And Ht Glove Pair ( 01 No Each ) 21 Providing Of 1 Kw Heat Convector For Operators For Winter Season. 22 Providing And Fitting Of 01 No. Led ( Scroll Type ) Sign Board Fabricated Out Of Stainless Steel And Metal Showing The Names Of Water Supply Scheme And The Department.Size:6’×1’6” 23 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site.Size: 4’×6’ Out Ms Angle Of 40X 40X 5Of 36 Rft And Ms Sheet Of 1 Mmthicktotal Weight Of50.16 Kgs 24 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mm Wide, Thickness 3Mm With 70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items. 1 ) 3 Way Terminal Connector 20 Amp.2 ) 3 No Mcb 8 Amp.Rest Specification As Per Cluase 50 Of Sbd. 25 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole Vide Item No.36 Having Following Specs:Input: 90-240 V 50 Hz Power Factor: >0.9Colour Temperature: 4K - 6.5Kbeam Angle: 120° - 170° Lumens: >12000Operating Temperature: -20°C To 60°Crest Specification As Per Cluase 51 Of Sbd. 26 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 27 Earth Work In Excavation Required For Installation Ofgantry Mechanismand Associated Worksby Manual Means In Trenches For Foundation, Drains, Pipes, Cables ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed In All Kinds Of Soil. 28 Providing And Laying Of Soling Stone 29 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With 1: 2 : 4 ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) . 30 Centering And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For Foundation, Footings, Bases For Columns 31 Painting Of The 2 No. Gantry And Plate Form Of Wellusing One Coat Of Red Oxide Metal Primer And Two Coats Of Enamel Paintof Different Shades 32 Providing, Installation Andtestingof Manual Type Triple Spur Gearchain Pulley Block Along With Monorail Gearedtravelling Trolleyhaving Following Features Capacity=2 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 Mdetailed Techinical Specification As Per Cluase 24 Of Sbd 33 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: -Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide.The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 34 Providing & Fitting Of Dozing Pumps To Doze Required Quantity Of Alum / Chlorine In The System. The Capacity Of The Dozing Units Shall Be 0-12 Lph Capacity. Dozing Pups Shall Be Provided With All Required Accessories Including 200 Ltrs. Pvc Tanks And Cable For Connection. Each Pump Shall Be Provided With 20 Mtrs. Cable As Per Required Specification. 35 Providing And Fitting Of Pressure Gauges With Adopters To Replace Damaged Ones .These Pressure Gauges Should Be In The Range Of 0-50 Kgf / Cm / Sg And Bereputed Make. 36 Removal Of Choked Filter Media From 5000 / 6000 Gph Pressure Filter Vessel. The Job Includes All Loads And Lifts, Disposal Of Choked Media To Dumping Site Outside The Premises Of The Plant Within A Lead Of 5 Km. The Vessel Needs To Be Cleaned Properly And Dried Before Laying Of Fresh Media. 37 Providing And Laying Of Filter Media Of Specific Size And Grade To Be Laid In 5000 Gph Pressure Vessels ( 02 No ) Duly Washed, Free From Dust , Dirt , Loom And Any Other Inorganic Materialor Suspension .The Job Includes Carriage Of Filtermedia From Ganderbalto Site Including Allall Loads And Liftsrequired On The Site Condition. The Media Is To Be Lad In Different Layers Of Specific Size And Grade From Bottom To Top Over The Filter Bed Plate. The Bottom Layer Is To Be Laid Without Tilling / Damaging The Pressure Nozzles. 38 Providing And Fitting Of 12 Mm Dia. Fine Threaded Pvc Nozzles Auxiliary Type To Be Fitted On Filter Bed Plate Of Pressure Vessels ( 02 Nos ) . 39 Providing And Fitting Of 29 Inch. Dia. Rubber Washers / Gaskets For Manhole And Inspection Chamber And Opening Of Pressure Filter Vessel. 40 Providing And Fitting Of 3”X5 / 8” Nuts And Bolts. 41 Overhauling Of Backwash Unitof 5000 Pressure Vessel ( 02 No ) By Way Of Dismantling Of Unit Parts Assembling Cleaning, Oiling, Greasing, Replacement Of Any Damaged Parts, Refining Of Sub Assemblies & Installation Of Backwash Unit With Its Existing Suction & Delivery Outlet. Job Includes P / F Of Packing & Consumables. 42 Overhauling Of Air Scavanging / Blower Unit 5000 Gph Pressure Vessel ( 02 Unit ) By Way Of P / F Of Reducing Pressure Weights, Filling Of Oil, Replacement Of Pressure Valves. Job Includes Oiling, Greasing & Fitting Of Consumables. 43 Painting With Synthetic Enamel Paint Two Or More Coats Of Approved Brand And Bar Pressure Clarifier Pressure Filter Vessel, Fittings And Complete Piping After Cleaning Of Dirt By Kerosene Oil And Application Of Steel Primer Of Specific Grade. 44 02. ( Part A ) Wss Shiganpora ( Adv. Cost: Rs. 12, 03, 279 / - ) 45 Supply, Installation, Testing & Commissioning Of Submersible Pumping Unitas Per Is 8034 With Following Specification Are As Under:Pump : Efficiency = Not Less Than 50% Speed= 2900 Rpmtype Of Pump = Mixed Flow.Type Of Fluid To Be Handled=Clear Watermaterial Of Construction:Impeller= Stainless Steelpump Shaft = Stainless Steel Ss 410.Pump Casing = Cast Iron / Stainless Steelmotor:-Method Ofstarting = Star – Deltaspeed = 3000 ( Sync ) .Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 Phaseefficiency = Not Less Than 90%Rating: 10 Hpmanufacture Test Certificate To Be Appended. Rest Ofspecification As Per Cluase 1Of Technical Anexure Of Sbd 46 Fabrication, Providing, Fitting And Lowering Of 65Mm Diameter B Class ( Medium Class ) Column Pipe Conforming To Is: 1239 Of Length 10 Rft Into The 200 / 250 / 300 Mm Casing Dia L. Production Well / Dug Wel Up To The Desired Depth ; The Job Includes Providing And Welding Of Flanges Conforming Tois: 6392, Table-05 And Pn 16 To These Pipes And Welding Of Flanges In Two Layers To Make The Flanged Joint Strong And Leak Proof. The Pipe Of 10 Ft Length Is To Be Weld On Both Sides With Flanges Using Welding Rod Of Reputed Make. The Job Includes All Types Of Skilled Labours, Arrangement Of Power Supply / Diesel Generator Set Etc Required For The Job Including P / F Of Suitable Size Nuts Bolts And R.I Gasket In The Flanged Joints Of Column Pipes. The Job Further Includes Cutting Of 2 No. Rectangular Cable Slots In Each Flange. 47 Fabrication, Providing And Fitting Of 65 Mm Size Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. ( 02 Pair ) 48 Fabrication, Providing And Fitting Of90-120 Degree Bend / Elbowto Be Fabricated Out Of80 Mm Diameter Class-C, G.I Pipe, 1 M Lengthand Flanged On Both Ends Andto Make It Leak Proof. The Flanges Shall Be M.S Flanges Conforming To Bis 6392 / 1997 Table 05 ( Rating Pn16 ) And Welded On Both Sides. The Job Includes Nuts, Bolts, Gaskets Etc As Per Site Requirement. 49 Providing And Fitting Of 300Mm In Length 80Mm Dia Gireducerflanged On Both Sides, Flange Conforming To Table-05 ( Pn16 ) To Be Fitted With The Column Pipe / Delivery Manifold Of Submersible Pumping Unit To Join Rising-Main And Column Pipe / Delivery Manifold. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes From Inside And Outside Of Pipe To Form Strong Welding Joint. 50 Fabrication, Providing And Fitting Of 80Mm Dia Washout Tee With Arm Length 1.2 Feet Each. The Tee Shall Be Fabricated Out Of G.I C-Class Pipe With M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends. 51 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .The Body And Bonnent Of The Valve Shall Be Of Ductile Iron, Wedge With Fully Vulcanized Epdmrubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valve Shall Be Compatible Forburied Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positionsrest Specification As Per Cluase 12 Of Sbd. Size: Dn80pn:1.6 / 16 52 Providing And Fitting Of Ductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdmrubber ( Approved For Drinking Water ) .Rest Specification As Per Cluase 13 Of Sbd. Size: 80Mmpn: 1.6 / 16 53 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 54 Earth Work In Excavation Required For Installation Ofgantry Mechanismand Associated Worksby Manual Means In Trenches For Foundation, Drains, Pipes, Cables ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed In All Kinds Of Soil. 55 Providing And Laying Of Soling Stone 56 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With 1: 2 : 4 ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) . 57 Painting Of The 2 No. Gantry And Plate Form Of Wellusing One Coat Of Red Oxide Metal Primer And Two Coats Of Enamel Paintof Different Shades 58 Providing, Installation Andtestingof Manual Type Triple Spur Gearchain Pulley Block Along With Monorail Gearedtravelling Trolleyhaving Following Features Capacity=2 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 M Detailed Techinical Specification As Per Cluase 24 Of Sbd 59 Providing And Fittingg.I Channel / Angle / Flat Of Sizes Including Clamps 60 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Ofht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Rated Voltage 11Kv 200A Complete As Per Is Specs. 61 Supply, Installation, Testing And Commissioning Of 11Kvpolymer Fuses Sethorn Gap3-Phase 200 Asuitable For Vertical Installation . 62 Supply, Installation, Testing And Commissioning Ofgapless Surgearrestor Station Class, 10Ka, 9Kv, La With Polymer Housing, Station Type . 63 Supply And Fitting Of 11 Kv Polymeric Composite Pin Insulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative, Creepagedistance 320 Mm 64 Providing And Fitting Of Acsr As Per Is 398 ( Part-2 ) 1996 0.05 Acsr ( Galvanised Steel Reinforced. 65 Fabrication, Providing And Fitting Ofmodularmotor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class: Ip-55 & Fitted With Accessories As Under:Rating = 10 Hp Rest Specifications As Per Cluase - 43-Bof Sbd 66 Providing, Fitting, Testing And Commissioning Of 40 Kva Voltage Stabilizeras Per Specifications Below: Type Of Voltage Controller: Manually Operated Copper Wound, 3-Phase, Ac Power Supply Multi Step.Type Of Regulator: Double Plate Type With Electrolytic Copper Contacts.Input Voltage : 175-400 Volts. ( 3 Phase ) Output Voltage : 400 ±10% Volts.Frequency : 50±3 C / S.Windings : Electrolytic Grade Copper Of Adequate Section, Vacuum Impregnated And Oven-Dried.Insulation : Fiber Glass Insulations To Tested Parameters.Cooling: Naturally, Oil Cooledtemp. Rise ( Max ) : 30°C Above Ambientmounting : On Uni-Directional Wheels.Correction Rate : 30 Volts Per Stepwave Form Distortion: Virtually Nilduty Cycle : 100% Continuous.Enclosure : Ms Sheet Enclosure In Pressed Cgr Sheet Powder Coated With Radiators.Core Laminates: High Grade, Low Eddy Loss, Grain Oriented Silicon Steel Laminations.Load: Three Phase Induction Motor Load.Load Amperes ( Continuous ) Rest Oftechnical Specification As Per Cluase 45Of Technical Anexure Of Sbd 67 Providing And Fitting Of 3 / 3.5 / 2-Core, Xlpe Armoured Aluminium Cable Conforming To Is: 7089 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc.Note:- The Cable Terminal Ends For Connection To Switchgear At Various Requisite Points Shall Be Al. Thimbles Of Dowel’S Make And Of Appropriate Size And Connected By Hydraulic Crimp Tool Only.I ) 50 Sqmm, 3.5Core 68 Providing And Fitting Of 3-Core Flat 10 Sq.Mm Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipments . The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. 69 P / I Of Earthing Station For Substation, Lt Panel, Dg Set And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards.Safe Earthing Electrode Size :80 Mm Dia, Length :2000 Mmback Fill Compound :30 Kg 70 Supply, Installation Of 6 Kg Co2 Type Fire Extinguisher Manufactured As Per Is:15683 Of 2006 With Is Mark And Comply With Dgms ( Approval ) . The Co2 Extinguisher Should Be Suitable For Class B & C Fire And Also For Fire Involving Electrical Equipments. The Cylinder Used For Fire Extinguisher Shall Be Approved By Protroleum Andexplosive Safety Organization ( Peso ) As Per Gas Cylinder Rules 2004 And As Per Is: 7285 Of 2004. The Body Should Be Made Of Seamless Steel ( Manganese ) Confirming To Is:7285 With Is Mark And Should Be Provided With Squeeze Grip Nozzle And Should Be Filled With Co2 Confirming To Is : 15222 Of 2002 With Certificate.The Extinguisher Shall Be Provided With Manufactures Test Certificate And Hydraulic Test Certificate By Bis From Peso. 71 Supply, Installation, Testing & Commissioning Of 1000 Va Full Sine Wave Power Inverter ( Make: Microtek / Luminous ) Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover. ( Make: Amaron / Exide ) With 2-Core 4Mm2 Cu ( 25 Mtr ) Wiring As Per Site Requirement Along With Other Accessories Like Ss-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 72 Tool Kit For Maintenance: -The Tool Kit For Maintenance Shall Comprise Of The Following And All The Items As Mentioned Below Shall Be Of:Providing Of Tool Kit Consists Of Following Items Rest Specifications As Per Clause- 56 Of Sbd 73 Fabricationof6’ X 6’ Angle Iron Bed By Way Of Providingand Fitting Of Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 74 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 Nos Including Cutting , Fixingall Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 75 Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Srest Specifications As Per Clause -57 Of Sbd 76 Electrification Of Pump House By Way Of P / F Of:- Lighting Points In 1.0 Sq.Mm Multistrand Pvc Chanel / Condut.The Job Incl. P / F Of 5 Amp. Switch, Angle / Button Holder, 5 Watt Led Lamp With Necessary Fixtures ( 06 Jobs ) . Heating Points In 2.5 Sq.Mm Multistrand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Condut.The Job Includes P / F Of 16 Amp.Ss Combine ( 04 Jobs ) . 5 Pin Socket Points In 1.5 Sq.Mm Multistrand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. ( 04 Jobs ) .Cealing Fan C / W Regulator Switch, Wiring In1.5 Sq.Mm Multistrand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit And Necessary Fixtures ( 02 Jobs ) .Distribution Board Sp &N ( Regal Grey ) With 01 No Incomming And 8 Way Outgoing, Fitted With Mini McbC Series 6Amp.-04 No For Lighting Points And2 / 3 Pin Socket Points And Fans, 10 Amp-01 No For Flood Lights, 16 Amp-01 No For Heating Points, 36 Amp.Mcb ( Mains ) As Per Is Standard.The Fittings Shall Be Modular Type. 77 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply. 78 Providing Of Bamboo Ladders 18 Feet Long Along With 15 Feet Long Link Rods And Ht Glove Pair ( 01 No Each ) 79 Providing Of 1 Kw Heat Convector For Operators For Winter Season. 80 Providing And Fitting Of 01 No. Led ( Scroll Type ) Sign Board Fabricated Out Of Stainless Steel And Metal Showing The Names Of Water Supply Scheme And The Department. Size: 6’×1’6” = 9 Sft 81 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site.Size: 4’×6’ Out Ms Angle Of 40X 40X 5Of 36 Rft And Ms Sheet Of 1 Mmthicktotal Weight Of50.16 Kgs 82 ( Part B ) Pump House Of Wss Shiganpora ( Adv. Cost Rs. 19, 24, 620 / - ) 83 Earth Work In Excavation Over Areas Exceeding 30 Cm And Upto 1.5 M In Depth 1.5 M In Width As Well As 10 Sqm On Plan Inculding Disposal Of Excavated Soil Upto1mt From Cutting Edge. 84 Extra For Earth Work For Every Additional Lift Of 1.5 M Or Part Thereof 85 Providing And Laying Of Dry Stones Soling Tightly Hand Packed. 86 Provding And Laying Of 1:4:8 Nominal Mix Cement Concrete. 87 R.R Masonary With Quarry Stone Laid In 1:6 Cm 88 R.R Masonary With Quarry Stone Laid In 1:6 Dry 89 Providing And Laying Of 50 Mm Thick Dp Band Over Stone Work In 1:2:4 Nominal Mix 90 Brick Work With Ommon Brunt Clay F.P.S Bricks Of Class Designation 75 In Foundation And Plinth In 1:6 Cm. 91 Extra Over Brick In Super Structure Up To Floor V Level. 92 Providing And Fixing Of Wooden Chowkat In First Class Kail Wood. 93 Providing And Fixing Of 35Mm Thick Glazed Shutters For Doors And Windows First Class Kail Wood. 94 Providing And Fixing Panelled Or Panelled Andglazed Shutters For Doors And Windows 35Mm Thick Of Kail Wood. 95 Providing And Fixing Of Panelling Or Penelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors And Windows ; Penelling 25Mm To 40Mm Thick Of Kail Wood. 96 Providing And Fixing Of 35Mm Thick Wire Guage Shutters For Doors And Windows. 97 Reinforced Cement Concrete Work In 1:2:4 Nominal Mix With 20Mm N / S Stone Aggregate. 98 Providing Reinforcement To The Rcc Works Including Bending, Binding, Cutting Placing In Position Complete. 99 Centering And Shuttering Including Proping, Struting Etc And Removal Of Farm Work.Lintel / V Beam 100 Slab 101 Slab Edges 102 Providing 50Mm Thick Cement Concrete Flouring With Floating Coat Of Neat Cement. 103 12Mm Thick Cement Sand Plaster In 1:4 Mix 104 1:3 Mix With Floating Coat Of Neat Cementfor Saptic Tank. 105 Providing And Fixing 1St Quality Ceramic Glazed Tiles With Minimum Thickness 5Mm Of Approved Make Like Kajaria, Somany Etc. Over 12Mm Thick Cement Mortar In 1:3 Mix. 106 Providing And Laing / Fixing Ceramic Glazed Floor Tiles 300X300mm Of 1St Class Of Somany Or Kajaria Or Equilent Made Laid On 20Mm Thick Bed Of Lcement Mortar In 1:4 Mix. 107 Providing And Fixing Water Closet Squarting Pan ( Indian Type With 100Mm Sand Cast Iron P Or S Trap, 10 Lit, Low Level Pvc Flusingcistern Including Flushing Pipe And Making Good The Walls And Floors Wherever Required ( Orrisa Pattern With Intergral Foot Type ) . 108 Providing And Fixing Salem Stainless Steel Kitched Sink. Size 610X510x200mm 109 Providing And Fixing Of Pvc Wasit Pipe Sink Including Pvc Waist Fititng Complete ( Flexable 40 Mm Dia = 1 No ) 110 Providing And Fixing Of Sanitary Fititng 111 Structual Steel Works Welded In Built Up Section, Trusses And Framed Works Including Cutting Hoisting, Fixing In Position And Applying Priming Coat Of Approved Steel Primer Complete. 112 Providing And Fixing Corrogated G.S Sheets Including Vertical / Curved Surfaces With Polymer Coated J Or L Hooks ( 0.63 Mm Thick ) 113 Providing Ridge Or Hip Of Width 60Cm Over All With Plain Gs Sheets Fixed With Polymer Coated J Or L Hoors ( 0.63 Mm Thick ) 114 Providing And Fixing Of Coloured Eves Boarding 115 Providing And Fixing Of 12 Mm Thick Plyboard Soffit Along Wiith Supporting Of Frist Class Popular Wood Ballies. 116 Supplying And Fixing Rolling Shutter Of Approved Make Made Of Required Size Ms Lathes Interlocked Together Through Their Entire Length Etc Complete With 80X0.90 Mm Ms Laths With 0.90 Mm Thick Top Cover. 117 Providing And Applying White Cement Based Putty Of Approved Thickness 1Mm Of Approved Brand And Manufacture Over The Plastered Surfaces To Prepare The Surface Smooth And Even Complate. 118 Distempering Lwith 1St Quality Acrylic Distemper Of Approvedbrand And Manufacture Including Applyingadditional Lcoats Whereever Required To Achive Even Shade. ( Two Coats ) 119 Finishing Walls With Water Proofing Cement Paint Of Required Shade ( External ) ( Snowsum ) 120 Painting With Synthetic Enamal Paint Ofapproved Brand And Manufacture Of Required Colour To Give Even Shade Two Or More Coats On New Work Includingpriming Coat Of Approved Brand And Manufacture.A ) Wood Works 121 B ) On Steel Work 122 Add. Provision For Plumbing, And Electrification To The Quarter 123 Carriage Of Material From Source To Dumping Site At Road By Mechanical Transport A ) Cement And Steel For Average Lead Of 21 ( Km ) 124 B ) Sand For Average Lead Of 22 ( Km ) 125 C ) 20Mm Aggregate For Average Lead Of 22 ( Km ) 126 C ) 40Mm Aggregate For Average Lead Of 22 ( Km ) 127 E ) Bricks For Average Lead Of21 ( Km ) 128 F ) Quarry Stone For Average Lead Of20 ( Km ) 129 G ) Soling Stone For Average Lead Of21 ( Km ) 130 Extra Carriage Of Material From Dumping Site Actual Site By Mannual Labour.A ) Cementfor Average Lead Of 400 ( Mts ) 131 B ) Steel For Average Lead Of 400 ( Mts ) 132 C ) Sand & 20Mm Agg. For Average Lead Of400 ( Mts ) 133 C ) 40Mm Agg. For Average Lead Of400 ( Mts ) 134 E ) Bricks For Average Lead Of 400 ( Mts ) 135 F ) Quarry Stone For Average Lead Of400 ( Mts ) 136 G ) Soling Stone For Average Lead Of 400 ( Mts ) 137 03. ( Part A ) Wss Chekpora Brazloo ( Adv. Cost Rs. 22, 74, 365 / - ) 138 Supply, Installation, Testing & Commissioning Of Open Well Pumping Units As Per Is 14220 At Filter Water Stage. Pump: - • Type Of Pump:Open Wellsubmersible Pump ( Horizontal ) Discharge :10000 Gph, At 30 M Head.• Quality Of Waterto Be Handled :Filter Watermeterial Of Construction:• Pump Casing:Cast Iron• Impeller:Ss • Pump Shaft:Stainless Steel• Motor Body: Cast Iron • Sealing :Dual Mech. Seal ? The Bowl Plate Shall Be Provided With Name Plate Giving Complete Specifications ? Motor: -• Rating : Suitable For Above Parameter• Method Of Starting: Star – Delta.• Frequency: 50Hz + 3%• Voltage : 415 + 6 %, -15% • Class Of Insulation: Suitable For Above Rating. • Sealing: Dual Mech. Seal.Note: Manufacturers Test Certificate To Be Appended And Detailed Specification As Per Clause 3 Of Sbd ) Motor Rating :10 Hp 139 Fabrication, Providing, Fitting And Lowering Of B Class Column Pipe Conforming To Is: 1239 Of Length 10 Rft Into The 200 / 250 / 300 Mm Casing Dia. Production Well Up To The Desired Depth; The Job Includes Providing And Welding Of Flanges Conforming To Is: 6392, Table-17 And Pn 16 To These Pipes And Welding Of Flanges In Two Layers To Make The Flanged Joint Strong And Leak Proof. Detailed Specification As Per Cluase 7 Ofof Sbd Dn 100B ( Medium ) Pipe 140 Providing / Supplying And Fitting Of G.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class Bconfirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make.Flanges ( As Per Is 6392 / 1997 Table:17 ) Thickness Shall Conform To Is 6392 Part 1St Table-17. Detailed Spacifications As Per Clause 8 Of Sbd.Dn 125B ( Medium ) Pipe 141 Earth Work In Excavation Required For Installation Ofgantry Mechanismand Associated Worksby Manual Means In Trenches For Foundation , Drains , Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts , Wells , Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed In All Kinds Of Soil. 142 Filling Available Excavated Earth In Trenches, Plinth, Sides Of Foundation Etc.In Layers Not Exceeding 20 Cm In Depth , Consolidating Each Deposited Layer By Reaming And Watering , Lead Upto 50 M And Lift Upto 1.5M.Quantity : 90% Of Item No: 04 143 Fabrication, Providing, Fitting T- Junction Out Of 1 Mtr Of Pipe With Length Of1 Ft Each Arm The Job Includes All Types Of Skilled Labours, Arrangement Of Power Supply / Diesel Generator Set Etc Required For The Job Including P / F Of Suitable Size Nuts Bolts And R.I Gasket In The Flanged Jointsrest Specification As Per Cluase 09Of Sbd 125 Mm 144 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .The Body And Bonnent Of The Valve Shall Be Of Ductileiron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valve Shall Be Compatible For Buried Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positions. Rest Specifications As Per Clause 12 Of Sbd.125 Mm 145 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approved For Drinking Water ) .Rest Specification As Per Cluase 13Of Sbd125 Mm 146 Fabrication, Providing, Fitting Long Raduisbendout Of 1 Mtr Of Pipe With Length Of1 Ft Each Arm The Job Includes All Types Of Skilled Labours, Arrangement Of Power Supply / Diesel Generator Set Etc Required For The Job Including P / F Of Suitable Size Nuts Bolts And R.I Gasket In The Flanged Joints. Rest Specification As Per Cluase 15Of Sbd125 Mm 147 Fabrication, Providing And Fitting Of Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. ( 01 Pair ) Size: 80 Mm 148 Cutting Of Hot Dip Galvanized G.I, C-Class Pipe Across The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Also Includes Providing And Welding Of M.S Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17. :Rest Specification As Per Cluase 11Of Sbd. 125 Mm 149 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 150 Earth Work In Excavation Required For Installation Ofgantry Mechanismand Associated Worksby Manual Means In Trenches For Foundation , Drains , Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts , Wells , Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed In All Kinds Of Soil. 151 Providing And Laying Of Soling Stone 152 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering . All Work Upto Plinth Level With 1: 2 : 4 Mix ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) 153 Centering And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For Foundation , Footings , Bases For Columns 154 Painting Of The 2 No. Gantry And Plate Form Of Wellusing One Coat Of Red Oxide Metal Primer And Two Coats Of Enamel Paintof Different Shades 155 Providing, Installation Andtestingof Manual Type Triple Spur Gear Chain Pulley Block Along With Monorail Gearedtravelling Trolleyhaving Following Features Gears:- The Hoist Shall Have Precision Machine Case Hardened Alloy Steel Gear Mounted On Bearings And Housed In A Dust Proof Gear Box. The Lubrication Of Gears Should Be Of High Viscosity And Temperature For Longer Life Of Gears. Load Chain:-The Load Chain Be Made Of High Tensile Alloy Steel Having Wear Resistance And Greatest Mobility.Rest Specification As Per Cluase 24Of Sbd. 156 Fabrication, Providing And Fitting Ofmodularmotor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories Mu-G 15 Rest Spacification As Per Clause 43-------------- Of Sbd 157 Providing, Fitting, Testing And Commissioning Of 25Kva Voltage Stabilizeras Per Specifications Below: Type Of Voltage Controller: Manually Operated Copper Wound, 3-Phase, Ac Power Supply Multi Step.Type Of Regulator: Double Plate Type With Electrolytic Copper Contacts.Input Voltage : 250-400 Volts. ( 3 Phase ) Output Voltage : 400 ±10% Volts.Frequency : 50 ±3 C / S.Windings : Electrolytic Grade Copper Of Adequate Section, Vacuum Impregnated And Oven-Dried.Rest Spacification As Per Clause 44 Of Sbd 158 Providing And Fitting Of 2 Core, 3 Core, 3.5-Core, Xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming To Is: 7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc.Rest Specification As Per Cluase 71Of Sbd.35 Sqmm, 3.5 Core L.T 1.1 Kv 159 Providing And Fitting Of 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. The Main Specification Of The Cable Is Given Below:Rest Specification As Per Cluase 47Of Sbd.Size: 10 Sq.Mm 160 Providing And Fitting Ofpvc Iinsulated Copper Cable As Per Is 694-Along With Thimbling As Per Requirmentsrest Specification As Per Cluase 67 Of Sbd.16 Sq.Mm 1 Core Lt 1.1 Kv 161 Supply , Installation , Commissioning And Creation Of Pole Mounted, Outdoor Type Electric Sub Station As Per The Technical Specifications Given Here Under -Specifications Conforming To Is: 1180 ( Part 1 ) 2014 With Latest Amendments. Type: Ht / Lt Transformer Type Of Cooling:Onan. Operating Conditions:Input=11000 Voltsoutput =433 Volts Ac Supply In 3- Phase.Terminals:Input=3 No. Ht Bush Rods With Insulators, Washer, Nuts Etc.Output=4 No. Lt Bush Rods Switch Insulators, Washers, Nuts Etc.Core: The Core Shall Be Of High Permeability To Reduce Core Losses And The Strips Shall Be Of Suitable Size And Gauge. Transformer Coils: Suitable Number Of Ht And Lt Coils In Each Leg Of The Core. The Transformer Coils Shall Be Fabricated Out Of Superior Quality Aluminum Wire / Strips, Properly Wound. The Ht Transformer Is Completely Filled With Suitable Grade Transformer Oil Up To Required Level. The Job Includes Carriage, And All Leads And Lifts Involved.The Ht Transformer Shall Be Of Reputed Make From An Iso Certified Company As Per Relevant Standards And A Test Certificate Shall Be Provided Before Installation. The Transformer Shall Also Be Provided With Breather Fill With Silica Jel Crystals, Conservator With Oil Level Indicator, Explosion Vet And Adequate Radiator Fins / Tubes. The Impedance Of Transformer Shall Be As Per Is: 1180 ( Part 1 ) 2014 With Latest Amendments.Note: The Scope Of The Work Shall Include Obtaining Of Necessary Inspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificate.Rating: 63 Kva 162 Providing And Fittingg.I Channel / Angle / Flat Of Sizes Including Clamps 163 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Ofht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Rated Voltage 11Kv 200A Complete As Per Is Specs. 164 Supply, Installation, Testing And Commissioning Of 11Kv Polymer Fuses Set Horn Gap 3-Phase 200 A Suitable For Vertical Installation 165 Supply, Installation, Testing And Commissioning Of Gapless Surge Arrestor Station Class, 10Ka, 9Kv, La With Polymer Housing, Station Type 166 Supply And Fitting Of 11 Kv Polymeric Composite Pin Insulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative , Creepagedistance 320 Mm 167 Supply, Installation, Erection Of 9 Mtrs Longh.T Pope Of Specifications St- 410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories .Wherever Required The Job Further Includes G.I Wire Earthing Of Pole As Per Rec Standard. 168 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement 169 Earth Work In Excavation By Manual Means In Trenches For Foundation, Drains, Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed.All Kinds Of Soil 170 Providing And Laying Of Soling Stone Including Manual Compaction 171 Concrete Cement Bottoming 1:2:4 Mix As Per Rec Standards , 0.5 Cum / Pole 172 P / F Danger Plate With Clamps 173 Providing And Fixing G.I Barbed Wire For Anti-Climbing / Anti-Climbing Devices 174 Providing And Fixinganti-Climbing Devices 175 Providing And Fitting Of Pg Clamps 176 Providing And Fitting Of Galvanized Stay Set With 50 X 8 Mm Stay Clamp , Guy Insulator ( 2No. ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts , 2 N0- Turn Buckle , 1.8 M Long , 16 Mm Diameter Solid G.I Stay Rod & 7 / 3.15 Mm Dia. G.I Stranded Wire Complete. 177 Painting Of Poles Red Oxide 178 Painting Of Poles Aluminum Paint 179 Providing And Fitting Of Acsr As Per Is 398 ( Part-2 ) 1996 For 50 Sq.Mmacsr ( Galvanised Steel Reinforced ) For Fitment Of Various Accessories 180 Supply, Installation, Testing Of 35 Sq Mm Xlpe Ht Cable ( Abc Type ) Of 11 Kv Grade With Following Specifications Size Cross Sectional Area In Squre Mm ) =3X35 Phases Red, Yellow , Blue 181 P / F Of 11 Kv Cable Termination Kit For Connecting 35 Sq Mm Xlpe Cable ( Abc Type ) With The Existing Ht Line Near Tapping Point And Ht Transformer. 182 Providing And Fitting Of Lt Distribution Box For H.T Transformer With Mccb For Incomer And Sfu For Outgoing Circuits. 63 Kva 183 P / I Of Earthing Station For Electric Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards. Safe Earthing Electrode Size:80 Mm Dia , Length:2000 Mmback Fill Compound :30 Kg 184 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mm Wide, Thickness 3Mm With 70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items.1 ) 3 Way Terminal Connector 20 Amp.2 ) 3 No Mcb 8 Amp. Rest Specification As Per Cluase 50Of Sbd. 185 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole Vide Item No.36 Having Following Specs:Input: 90-240 V 50 Hzpower Factor: >0.9Colour Temperature: 4K - 6.5Kbeam Angle: 120° - 170° Lumens: >12000Operating Temperature: -20°C To 60°Crest Specification As Per Cluase 51Of Sbd. 186 Providing And Installation Of Junction Box With Dp 32 A Mcb To Serve As Main Switch For Led Lighting. The Job Includes Making Of Electric Connection To The Circuit. 187 Providing And Fitting Of 2 Core, 3 Core, 3.5-Core, Xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming To Is: 7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc.Rest Specification As Per Cluase 71Of Sbd.10Mm2 2Core Lt 1.1 Kv 188 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer With Input Voltage 70-240 V And Output 220 V. The Stabilizer Shall Be Installed And Connected To The Electric Circuit As Per Location Provided By Site In Charge. 189 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover.With 2-Core 4 Mm2 Cu ( 25 M ) Wiring As Per Site Requirement Along With Other Accessories Like Ss-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 190 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: -Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide.The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 191 Tool Kit For Maintenance: -The Tool Kit For Maintenance Shall Comprise Of The Following And All The Items As Mentioned Below Shall Be Ofproviding Of Tool Kit Consists Of Following Items I. Double Ended Spanner ( Chrome Plated ) 02 Sets Complete Ii. Double Ended Ring Spannerschrome Plated02 Sets Completeiii. Allen Key Set Black Finish 02 Sets Complete Iv. Combination Pliers Insulated With Thick C.A Sleeve; Size In Mm 165, 210, 255Each – 02 No.V. Long Nose Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205Each – 02 No. Vi. Side Cutting Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205 Make – 02 No.Vii. Insulated Screw Drivers Blade Length In Mmblade Dia. In Mmtip Dimensions In Mm Quantity 50 3 1.6 X 0.4 0275 3 1.6 X0.4 02100 3 3 X 0.4 02125 3.5 3.5 X 0.502 150 3.5 3.5 X 0.5 02 200 4 4 X 0.6 02300 5 5 X 0.8 02Viii. Hammer With Handle Weight – 110 Mg, 340 Gm , 600 Gm –Each – 1No. .Ix. Heavy Duty Pipe Wrench Length In Mm - 200, 300, 600 Each – 01 No.X. Electric Multimeter=1Noxi. Digital Multimeter – 1No. Xii. Digital Clamp Tester Capable To Measure Up To 400A - 1 No. Xiii. Hack Saw Frame With Hack Saw Blade – 01 No. Xiv. S-16 Mxl, S- 16 H X L Socket Set ( 19 Sockets + 6 Accessories ) – 01 No. 192 A ) Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’Siv ) Single Bed Warm Blankets With One Sided Fur- 02 No’Sthe Filling Material For Mattress, Quilt And Pillow Shall Be Of Good Quality Cottonb ) The Job Also Includes Providing Of Pressure Cooker 5Ltr 02 No’S, Steel Patella ( Utensil ) 5Ltrs 02 No’S, Cooking Heater 01 No., Room Heater 01 No., Steel Buckets 10 Litre Capacity 01 No., Plastic Bucket 10 Litre Capacity With Mug 02 No’S Each, Steel Glasses 06 No’S, Steel Plates With Large Spoons And Bowls 03 No’S Each, Cup And Saucer Set ( 01 No. Set ) And, 5Kg Gas Cylinder With Burner / Stove. The Job Also Includes Providing Of Thermo-Cool 15’X12’ Along With Excel Matting Of 15’X12’ Size. The Job Also Includes Providing Of Unbreakable Plastic Chair Table Set Consisting Of Chairs 04 No’S, Extra Heavy Table 01 No. The Job Also Includes Providing Of Good Quality Safety Door Locks ( 03 No’S ) Of Godrej, Link Locks, 193 Fabricationof6’ X 6’ Angle Iron Bed By Way Of Providingand Fitting Of Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 194 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 No’S Including Cutting , Fixingall Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 195 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply. 196 Providing Of Bamboo Ladders 18 Feet Long Along With 15 Feet Long Link Rods And Ht Glove Pair ( 01 No Each ) 197 Providing Of 1 Kw Heat Convector For Operators For Winter Season 198 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipment Installed At Site Of Appropriate Sizes. 199 Design, Supply, Installation, Testing And Commissioning Of Automatic Power Factor Correctionpanel For Improvement Of Power Factor : 200 Providing, Installation, Testing & Commissioning Of 415 ±10%V ( Output ) , 3 Phase Air Cooled / Water Cooled Diesel Generator Set As Per Is 8528 ( 2018 ) And Iso 3046 ( 2002 ) For Engine And Iec / Is 60034-1 For Alternator Suitably Assembled And Fitted In A Pollution Free Acoustic Enclosure / Canopy Of Required Size As Per Ministry Of Environment Protection Rule 1986 Read With Latest Amendments. The Dg Set Is Required To Be Fitted And Tested On Load At Sitethe D.G Set Shall Have The Following Technical Specification.Besides The Above Works The D.G Set Shall Be Provided With 12 V, 150 Ah Lead Acid Battery Of Reputed Make Fitted Inside The D.G Set Canopy Along With Necessary Accessories And Battery Charger Of Required Capacity. The Job Also Includes The Cost On Account Of Hsd And Skilled Operator Required For Operation Of D.G Set For A Period Of 10 Hours Continuously During Its Testing And Commissioning Of D.G Set At Site. The Capacity Of The D.G Set Is Given Below:Rating: 25 Kva Dg Set 201 ( Part B ) Pump House Of Wss Checkpora Brazloo ( Adv. Cost Rs. 21, 32, 051 / - ) 202 Earth Work In Excavation Over Areas Exceeding 30 Cm And Upto 1.5 M In Depth 1.5 M In Width As Well As 10 Sqm On Plan Inculding Disposal Of Excavated Soil Upto1mt From Cutting Edge. 203 Extra For Earth Work For Every Additional Lift Of 1.5 M Or Part Thereof 204 Providing And Laying Of Dry Stones Soling Tightly Hand Packed. 205 Provding And Laying Of 1:4:8 Nominal Mix Cement Concrete With 40 Mm N / S Stone Aggregate 206 R.R Masonary With Quarry Stone Laid In 1:6 Cm 207 R.R Masonary With Quarry Stone Laid In 1:6 Dry 208 Providing And Laying Of 50 Mm Thick Dp Band Over Stone Work In 1:2:4 Nominal Mix 209 Pointing On Stone Work With Cement Mortar In 1:3 Mix ( Flush Type ) 210 Brick Work With Ommon Brunt Clay F.P.S Bricks Of Class Designation 75 In Foundation And Plinth In 1:6 Cm. 211 Extra Over Brick In Super Structure Up To Floor V Level. 212 Providing And Fixing Of Wooden Chowkat In First Class Kail Wood. 213 Providing And Fixing Of 35Mm Thick Glazed Shutters For Doors And Windows First Class Kail Wood. 214 Providing And Fixing Panelled Or Panelled Andglazed Shutters For Doors And Windows 35Mm Thick Of Kail Wood. 215 Providing And Fixing Of Panelling Or Penelling And Glazing In Panelled Or Panelledand Glazed Shutters For Doors And Windows ; Penelling 25Mm To 40Mm Thick Of Kail Wood. 216 Providing And Fixing Of 35Mm Thick Wire Guage Shutters For Doors And Windows. 217 Reinforced Cement Concrete Work In 1:2:4 Nominal Mix With 20Mm N / S Stone Aggregate. 218 Providing Reinforcement To The Rcc Works Including Bending, Binding, Cutting Placing In Position Complete. 219 Centering And Shuttering Including Proping, Struting Etc And Removal Of Farm Work.Lintel / V Beam 220 Slab 221 Slab Edges 222 Providing 50Mm Thick Cement Concrete Flouring With Floating Coat Of Neat Cement. 223 12Mm Thick Cement Sand Plaster In 1:4 Mix 224 1:3 Mix With Floating Coat Of Neat Cementfor Saptic Tank. 225 Providing And Fixing 1St Quality Ceramic Glazed Tiles With Minimum Thickness 5Mm Of Approved Make Like Kajaria, Somany Etc. Over 12Mm Thick Cement Mortar In 1:3 Mix. 226 Providing And Laing / Fixing Ceramic Glazed Floor Tiles 300X300mm Of 1St Class Of Somany Or Kajaria Or Equilent Made Laid On 20Mm Thick Bed Of Lcement Mortar In 1:4 Mix. 227 Providing And Fixing Water Closet Squarting Pan ( Indian Type With 100Mm Sand Cast Iron P Or S Trap, 10 Lit, Low Level Pvc Flusingcistern Including Flushing Pipe And Making Good The Walls And Floors Wherever Required ( Orrisa Pattern With Intergral Foot Type ) . 228 Providing And Fixing Salem Stainless Steel Kitched Sink. Size 610X510x200mm 229 Providing And Fixing Of Pvc Wasit Pipe Sink Including Pvc Waist Fititng Complete ( Flexable 40 Mm Dia = 1 No ) 230 Providing And Fixing Of Sanitary Fititng ( Ls ) 231 Structual Steel Works Welded In Built Up Section, Trusses And Framed Works Including Cutting Hoisting, Fixing In Position And Applying Priming Coat Of Approved Steel Primer Complete. 232 Providing And Fixing Corrogated G.S Sheets Including Vertical / Curved Surfaces With Polymer Coated J Or L Hooks ( 0.50 Mm Thick ) 233 Proving Ridge Or Hip Of Width 60Cm Over All With Plain Gs Sheets Fixed With Polymer Coated J Or L Hoors ( 0.50 Mm Thick ) 234 Providing And Fixing Of Ms Eves Boarding 300 Mm Wide And Soffit Boarding Including Priming Coat Of Red Oxide And Painting With Two Or More Coats With Synthetic Paint Of Approved Brand And Manufacture Complete Job 235 Providing And Applying White Cement Based Putty Of Approved Thickness 1Mm Of Approved Brand And Manufacture Over The Plastered Surfaces To Prepare The Surface Smooth And Even Complate. 236 Distempering Lwith 1St Quality Acrylic Distemper Of Approvedbrand And Manufacture Including Applyingadditional Lcoats Whereever Required To Achive Even Shade. ( Two Coats ) 237 Finishing Walls With Water Proofing Cement Paint Of Required Shade ( External ) ( Snowsum ) 238 Painting With Synthetic Enamal Paint Ofapproved Brand And Manufacture Of Required Colour To Give Even Shade Two Or More Coats On New Work Lincludingpriming Coat Of Approved Brand And Manufacture.Wood Works 239 Add. Provision For Plumbing , Iron Grills To Windows And Electrification To The Quarter Lump Sum To Be Paid As Per Actual ( L.S ) 240 Carriage Of Material From Source To Dumping Site At Road By Mechanical Transport A ) Cement And Steel For Average Lead Of 20 ( Km ) 241 B ) Sand For Average Lead Of 25 ( Km ) 242 C ) 20Mm Aggregate For Average Lead Of 27 ( Km ) 243 D ) 40Mm Aggregate For Average Lead Of 27 ( Km ) 244 E ) Bricks For Average Lead Of10 ( Km ) 245 F ) Quarry Stone For Average Lead Of15 ( Km ) 246 G ) Soling Stone For Average Lead Of06 ( Km ) 247 Head Load Of Material From Dumping Site To Actual Work Site For Average Lead Of.A ) Cementfor Average Lead Of 600 ( Mts ) 248 B ) Steel For Average Lead Of 600 ( Mts ) 249 C ) Sand & 20Mm Agg. For Average Lead Of600 ( Mts ) 250 D ) 40Mm Agg. For Average Lead Of600 ( Mts ) 251 E ) Bricks For Average Lead Of 600 ( Mts ) 252 F ) Quarry Stone For Average Lead Of600 ( Mts ) 253 G ) Soling Stone For Average Lead Of 600 ( Mts ) 254 04. ( Part A ) Wss Chatripora Gassrena ( Adv. Cost Rs. 51, 17, 327 / - ) 255 Supply, Installation, Testing & Commissioning Of Submersible Pumping Unit As Per Is 8034 With Following Specification Are As Under:Pump: Efficiency= Not Less Than 50%Speed= 2900 Rpm Type Of Pump= Mixed Flow. Type Of Fluid To Be Handled = Clear Watermaterial Of Construction: Impeller= Stainless Steel Pump Shaft= Stainless Steel Ss 410. Pump Casing Cast Iron / Stainless Steelimpeller: Impeller Is Of The Enclosed Or Semi – Enclosed Type And Properly Balanced.Enclosed Impellers Equipped With Seal Rings On Their Hubs. Coupling: A Suitable Coupling Arrangement Provided With Pump Set. Non Return Valve: - Non Return Valve Of The Suitable Size Provided Above The Pump Discharge Case.Motor:- Method Ofstarting = Star – Delta Speed = 3000 ( Sync ) . Frequency= 50 ± 3 % Hz Working Voltage = 380-415 ± 15% V, 03 Phase Efficiency= Not Less Than 90%Rating=Suitable For Above Parametersclass Of Insulation=F / Suitable For Above Parameters Note: Providing Of Test Certificate & Characteristic Curve Of Pumping Equipment Is Compulsory And Pumping Unit Is To Be Approved From The Concerned Sub Divisional Office Before Procuring. Motor Rating: 25 Hp 256 Fabrication, Providing, Fitting And Lowering Of B Class Column Pipe Conforming To Is: 1239 Of Length 10 Rft Into The 200 / 250 / 300 Mm Casing Dia. Production Well Up To The Desired Depth; The Job Includes Providing And Welding Of Flanges Conforming To Is: 6392, Table-17 And Pn 16 To These Pipes And Welding Of Flanges In Two Layers To Make The Flanged Joint Strong And Leak Proof. The Pipe Of 10 Ft Length Is To Be Weld On Both Sides With Flanges Using Welding Rod Of Reputed Make. The Job Includes All Types Of Skilled Labours, Arrangement Of Power Supply / Diesel Generator Set Etc Required For The Job Including P / F Of Suitable Size Nuts Bolts And R.I Gasket In The Flanged Joints Of Column Pipes. The Job Further Includes Cutting Of 2 No. Rectangular Cable Slots In Each Flange. Dn 80B ( Medium ) Pipe 257 Providing / Supplying And Fitting Of G.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class B And C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make.Flanges ( As Per Is 6392 / 1997 Table:17 ) Thickness Shall Conform To Is 6392 Part 1St Table-17. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint. Welding Electrodedc Arc Welding Using Welding Electrode Having Diameter Not Less Than 4Mm. Nuts And Bolts Nuts And Bolts ( Conforming To Is:1363 Part 1St ) Rubber Insertion Gaskets Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. The Main Technical Specifications Of The Pipe Are Given Here Under:Dn 80C ( Heavy ) Pipe 258 Earth Work In Excavation Required For Installation Ofgantry Mechanismand Associated Worksby Manual Means In Trenches For Foundation , Drains , Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts , Wells , Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed In All Kinds Of Soil. 259 Filling Available Excavated Earth In Trenches, Plinth, Sides Of Foundation Etc.In Layers Not Exceeding 20 Cm In Depth , Consolidating Each Deposited Layer By Reaming And Watering , Lead Upto 50 M And Lift Upto 1.5M.Quantity : 90% Of Item No: 04 260 Fabrication, Providing And Fitting Of Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. ( 01 Pair ) Size: 80 Mm 261 Fabrication , Providing And Fitting Of90-120 Degree Bend / Elbowto Be Fabricated Out Of80mm Diameter Class-C, G.I Pipe, 1 M Lengthand Flanged On Both Ends Andto Make It Leak Proof. The Flanges Shall Be M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) And Welded On Both Sides. The Job Includes Nuts, Bolts, Gaskets Etc As Per Site Requirement.80 Mm C 262 Cutting Of Hot Dip Galvanized G.I, C-Class Pipe Across The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Also Includes Providing And Welding Of M.S Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17.Rest Specification As Per Cluase 11Of Sbd. 80 Mm 263 Fabrication, Providing, Fitting T- Junction Out Of 1 Mtr Of Pipe With Length Of1 Ft Each Arm The Job Includes All Types Of Skilled Labours, Arrangement Of Power Supply / Diesel Generator Set Etc Required For The Job Including P / F Of Suitable Size Nuts Bolts And R.I Gasket In The Flanged Jointsrest Specification As Per Cluase 09Of Sbd 80 Mm 264 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .The Body And Bonnent Of The Valve Shall Be Of Ductileiron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valve Shall Be Compatible For Buried Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positionsrest Specification As Per Cluase 12Of Sbd.80 Mm 265 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approved For Drinking Water ) .Rest Specification As Per Cluase 13Of Sbd.80 Mm 266 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 267 Earth Work In Excavation Required For Installation Ofgantry Mechanismand Associated Worksby Manual Means In Trenches For Foundation , Drains , Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts , Wells , Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed In All Kinds Of Soil. 268 Providing And Laying Of Soling Stone 269 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering . All Work Upto Plinth Level With 1: 2 : 4 Mix ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) 270 Centering And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For Foundation , Footings , Bases For Columns 271 Painting Of The 2 No. Gantry And Plate Form Of Wellusing One Coat Of Red Oxide Metal Primer And Two Coats Of Enamel Paintof Different Shades 272 Providing, Installation Andtestingof Manual Type Triple Spur Gear Chain Pulley Block Along With Monorail Gearedtravelling Trolleyhaving Following Features Gears:- The Hoist Shall Have Precision Machine Case Hardened Alloy Steel Gear Mounted On Bearings And Housed In A Dust Proof Gear Box. The Lubrication Of Gears Should Be Of High Viscosity And Temperature For Longer Life Of Gears. Load Chain:-The Load Chain Be Made Of High Tensile Alloy Steel Having Wear Resistance And Greatest Mobility. Rest Specification As Per Cluase 24Of Sbd.2 Ton 273 Fabrication, Providing And Fitting Ofmodularmotor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories Mu-G 30 Rest Spacification As Per Clause 43-------------- Of Sbd 274 Providing, Fitting, Testing And Commissioning Of 50Kva Voltage Stabilizeras Per Specifications Below: Type Of Voltage Controller: Manually Operated Copper Wound, 3-Phase, Ac Power Supply Multi Step.Type Of Regulator: Double Plate Type With Electrolytic Copper Contacts.Input Voltage : 250-400 Volts. ( 3 Phase ) Output Voltage : 400 ±10% Volts.Frequency : 50 ±3 C / S.Windings : Electrolytic Grade Copper Of Adequate Section, Vacuum Impregnated And Oven-Dried.Rest Spacification As Per Clause 44 Of Sbd 275 Providing And Fitting Of 2 Core, 3 Core, 3.5-Core, Xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming To Is: 7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc. Rest Specification As Per Cluase 71Of Sbd.50 Sqmm, 3.5 Core L.T 1.1 Kv 276 Providing And Fitting Of 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) –1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. The Main Specification Of The Cable Is Given Below:Rest Specification As Per Cluase 47Of Sbd.10 Sq.Mm 277 Providing And Fitting Ofpvc Iinsulated Copper Cable As Per Is 694-Along With Thimbling As Per Requirmentsrest Specification As Per Cluase 67 Of Sbd.16 Sq.Mm 1 Core Lt 1.1 Kv 278 P / I Of Earthing Station For Electric Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards. Safe Earthing Electrode Size:80 Mm Dia , Length:2000 Mmback Fill Compound :30 Kg 279 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mm Wide, Thickness 3Mm With 70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items.1 ) 3 Way Terminal Connector 20 Amp.2 ) 3 No Mcb 8 Amp. Rest Specification As Per Cluase 50Of Sbd. 280 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole Vide Item No.36 Having Following Specs:Input: 90-240 V 50 Hzpower Factor: >0.9Colour Temperature: 4K - 6.5Kbeam Angle: 120° - 170° Lumens: >12000Operating Temperature: -20°C To 60°Crest Specification As Per Cluase 51Of Sbd. 281 Providing And Fitting Of 2 Core, 3 Core, 3.5-Core, Xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming To Is: 7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc. Rest Specification As Per Cluase 71Of Sbd.10 Sqmm 2Core Lt 1.1 Kv 282 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer With Input Voltage 70-240 V And Output 220 V. The Stabilizer Shall Be Installed And Connected To The Electric Circuit As Per Location Provided By Site In Charge. 283 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover.With 2-Core 4 Mm2 Cu ( 25 M ) Wiring As Per Site Requirement Along With Other Accessories Like Ss-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 284 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: -Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide.The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 285 Tool Kit For Maintenance: -The Tool Kit For Maintenance Shall Comprise Of The Following And All The Items As Mentioned Below Shall Be Ofproviding Of Tool Kit Consists Of Following Items I. Double Ended Spanner ( Chrome Plated ) 02 Sets Completeii. Double Ended Ring Spannerschrome Plated02 Sets Completeiii. Allen Key Set Black Finish 02 Sets Completeiv. Combination Pliers Insulated With Thick C.A Sleeve; Size In Mm 165, 210, 255Each – 02 No.V. Long Nose Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205Each – 02 No.Vi. Side Cutting Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205 Make – 02 No.Vii. Insulated Screw Drivers Blade Length In Mmblade Dia. In Mmtip Dimensions In Mm Quantity 50 3 1.6 X 0.4 0275 3 1.6 X0.4 02100 3 3 X 0.4 02125 3.5 3.5 X 0.502150 3.5 3.5 X 0.5 02200 4 4 X 0.6 02300 5 5 X 0.8 02Viii. Hammer With Handle Weight – 110 Mg, 340 Gm , 600 Gm –Each – 1No. . Ix. Heavy Duty Pipe Wrench Length In Mm - 200, 300, 600 Each – 01 No.X. Electric Multimeter=1Noxi. Digital Multimeter – 1No.Xii. Digital Clamp Tester Capable To Measure Up To 400A - 1 No.Xiii. Hack Saw Frame With Hack Saw Blade – 01 No.Xiv. S-16 Mxl, S- 16 H X L Socket Set ( 19 Sockets + 6 Accessories ) – 01 No. 286 Fabricationof6’ X 6’ Angle Iron Bed By Way Of Providingand Fitting Of Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 287 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 No’S Including Cutting , Fixingall Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 288 A ) Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’Siv ) Single Bed Warm Blankets With One Sided Fur- 02 No’Sthe Filling Material For Mattress, Quilt And Pillow Shall Be Of Good Quality Cottonb ) The Job Also Includes Providing Of Pressure Cooker 5Ltr 02 No’S, Steel Patella ( Utensil ) 5Ltrs 02 No’S, Cooking Heater 01 No., Room Heater 01 No., Steel Buckets 10 Litre Capacity 01 No., Plastic Bucket 10 Litre Capacity With Mug 02 No’S Each, Steel Glasses 06 No’S, Steel Plates With Large Spoons And Bowls 03 No’S Each, Cup And Saucer Set ( 01 No. Set ) And, 5Kg Gas Cylinder With Burner / Stove. The Job Also Includes Providing Of Thermo-Cool 15’X12’ Along With Excel Matting Of 15’X12’ Size. The Job Also Includes Providing Of Unbreakable Plastic Chair Table Set Consisting Of Chairs 04 No’S, Extra Heavy Table 01 No. The Job Also Includes Providing Of Good Quality Safety Door Locks ( 03 No’S ) Of Godrej, Link Locks, 289 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply. 290 Providing Of Bamboo Ladders 18 Feet Long Along With 15 Feet Long Link Rods And Ht Glove Pair ( 01 No Each ) 291 Providing Of 1 Kw Heat Convector For Operators For Winter Season 292 Providing And Fitting Of 01No Led ( Scroll Type ) Sign Board Fabricated Out Of Stainless Steel And Metal Showing The Name Of Wss And The Departmentsizen 6X1.6 293 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipment Installed At Site Of Appropriate Sizes. 294 Providing, Installation, Testing & Commissioning Of 415 ±10%V ( Output ) , 3 Phase Air Cooled / Water Cooled Diesel Generator Set As Per Is 8528 ( 2018 ) And Iso 3046 ( 2002 ) For Engine And Iec / Is 60034-1 For Alternator Suitably Assembled And Fitted In A Pollution Free Acoustic Enclosure / Canopy Of Required Size As Per Ministry Of Environment Protection Rule 1986 Read With Latest Amendments. The Dg Set Is Required To Be Fitted And Tested On Load At Sitethe D.G Set Shall Have The Following Technical Specification.Besides The Above Works The D.G Set Shall Be Provided With 12 V, 150 Ah Lead Acid Battery Of Reputed Make Fitted Inside The D.G Set Canopy Along With Necessary Accessories And Battery Charger Of Required Capacity. The Job Also Includes The Cost On Account Of Hsd And Skilled Operator Required For Operation Of D.G Set For A Period Of 10 Hours Continuously During Its Testing And Commissioning Of D.G Set At Site. The Capacity Of The D.G Set Is Given Below:Rating: 40 Kva Dg Set 295 Supply , Installation , Commissioning And Creation Of Pole Mounted, Outdoor Type Electric Sub Station As Per The Technical Specifications Given Here Under -Specifications Conforming To Is: 1180 ( Part 1 ) 2014 With Latest Amendments. Type: Ht / Lt Transformer Type Of Cooling:Onan. Operating Conditions:Input=11000 Voltsoutput =433 Volts Ac Supply In 3- Phase.Terminals:Input=3 No. Ht Bush Rods With Insulators, Washer, Nuts Etc.Output=4 No. Lt Bush Rods Switch Insulators, Washers, Nuts Etc.Core: The Core Shall Be Of High Permeability To Reduce Core Losses And The Strips Shall Be Of Suitable Size And Gauge. Transformer Coils: Suitable Number Of Ht And Lt Coils In Each Leg Of The Core. The Transformer Coils Shall Be Fabricated Out Of Superior Quality Aluminum Wire / Strips, Properly Wound. The Ht Transformer Is Completely Filled With Suitable Grade Transformer Oil Up To Required Level. The Job Includes Carriage, And All Leads And Lifts Involved.The Ht Transformer Shall Be Of Reputed Make From An Iso Certified Company As Per Relevant Standards And A Test Certificate Shall Be Provided Before Installation. The Transformer Shall Also Be Provided With Breather Fill With Silica Jel Crystals, Conservator With Oil Level Indicator, Explosion Vet And Adequate Radiator Fins / Tubes. The Impedance Of Transformer Shall Be As Per Is: 1180 ( Part 1 ) 2014 With Latest Amendments.Note: The Scope Of The Work Shall Include Obtaining Of Necessary Inspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificate.63 Kva 296 Providing And Fittingg.I Channel / Angle / Flat Of Sizes Including Clamps 297 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Ofht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Rated Voltage 11Kv 200A Complete As Per Is Specs. 298 Supply, Installation, Testing And Commissioning Of 11Kv Polymer Fuses Set Horn Gap 3-Phase 200 A Suitable For Vertical Installation 299 Supply, Installation, Testing And Commissioning Of Gapless Surge Arrestor Station Class, 10Ka, 9Kv, La With Polymer Housing, Station Type 300 Supply And Fitting Of 11 Kv Polymeric Composite Pin Insulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative , Creepagedistance 320 Mm 301 Supply, Installation, Erection Of 9 Mtrs Longh.T Pope Of Specifications St- 410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories .Wherever Required The Job Further Includes G.I Wire Earthing Of Pole As Per Rec Standard. 302 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement 303 P / F Danger Plate With Clamps 304 Providing And Fixing G.I Barbed Wire For Anti-Climbing / Anti-Climbing Devices 305 Providing And Fitting Of Pg Clamps 306 Providing And Fixinganti-Climbing Devices 307 Providing And Fitting Of Galvanized Stay Set With 50 X 8 Mm Stay Clamp , Guy Insulator ( 2No. ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts , 2 N0- Turn Buckle , 1.8 M Long , 16 Mm Diameter Solid G.I Stay Rod & 7 / 3.15 Mm Dia. G.I Stranded Wire Complete. 308 Painting Of Poles Red Oxide 309 Painting Of Poles Aluminum Paint 310 Providing And Fitting Of Acsr As Per Is 398 ( Part-2 ) 1996 For 50 Sq.Mmacsr ( Galvanised Steel Reinforced ) For Fitment Of Various Accessories 311 Supply, Installation, Testing Of 35 Sq Mm Xlpe Ht Cable ( Abc Type ) Of 11 Kv Grade With Following Specifications Size Cross Sectional Area In Squre Mm ) =3X35 Phases Red, Yellow , Blue 312 Providing And Fitting Of Anchoring Clampscomprising Clamp Body , Plastic Wedge, Steel Bill Bracket , Straps And Buckles Or Nuts And Bolts Required For Holding Of 3 – Core , 35 Sq. Mm H.T Ab Cable. 313 P / F Of 11 Kv Cable Termination Kit For Connecting 35 Sq Mm Xlpe Cable ( Abc Type ) With The Existing Ht Line Near Tapping Point And Ht Transformer. 314 Earth Work In Excavation Required For Installation Ofgantry Mechanismand Associated Worksby Manual Means In Trenches For Foundation , Drains , Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts , Wells , Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed In All Kinds Of Soil. 315 Providing And Laying Of Soling Stone 316 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering . All Work Upto Plinth Level With 1: 2 : 4 Mix ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) 317 Providing And Fitting Of Lt Distribution Box For H.T Transformer With Mccb For Incomer And Sfu For Outgoing Circuits. 63 Kva 318 ( Part B ) Pump House Of Wss Chatripora Gassrena ( Adv. Cost Rs. 17, 69, 433 / - ) 319 Earth Work In Excavation Over Areas Exceeding 30 Cm And Upto 1.5 M In Depth 1.5 M In Width As Well As 10 Sqm On Plan Inculding Disposal Of Excavated Soil Upto1mt From Cutting Edge. 320 Providing And Laying Of Dry Stones Soling Tightly Hand Packed. 321 Provding And Laying Of 1:4:8 Nominal Mix Cement Concrete. 322 R.R Masonary With Quarry Stone Laid In 1:6 Cm 323 R.R Masonary With Quarry Stone Laid In 1:6 Dry 324 Providing And Laying Of 50 Mm Thick Dp Band Over Stone Work In 1:2:4 Nominal Mix 325 Pointing On Stone Workwith Cement Mortor In 1:3 Mix ( Flush Type ) 326 Brick Work With Ommon Brunt Clay F.P.S Bricks Of Class Designation 75 In Foundation And Plinth In 1:6 Cm. 327 Extra Over Brick In Super Structure Up To Floor V Level. 328 Providing And Fixing Of Wooden Chowkat In First Class Kail Wood. 329 Providing And Fixing Of 35Mm Thick Glazed Shutters For Doors And Windows First Class Kail Wood. 330 Providing And Fixing Panelled Or Panelled Andglazed Shutters For Doors And Windows 35Mm Thick Of Kail Wood. 331 Providing And Fixing Of Panelling Or Penelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors And Windows ; Penelling 25Mm To 40Mm Thick Of Kail Wood. 332 Providing And Fixing Of 35Mm Thick Wire Guage Shutters For Doors And Windows. 333 Reinforced Cement Concrete Work In 1:2:4 Nominal Mix With 20Mm N / S Stone Aggregate. 334 Providing Reinforcement To The Rcc Works Including Bending, Binding, Cutting Placing In Position Complete. 335 Centering And Shuttering Including Proping, Struting Etc And Removal Of Form Work.Lintel / V Beam 336 Slab 337 Slab Edges 338 Providing 50Mm Thick Cement Concrete Flouring With Floating Coat Of Neat Cement. 339 A ) 12Mm Thick Cement Sand Plaster In 1:4 Mix 340 B ) 1:3 Mix With Floating Coat Of Neat Cementfor Saptic Tank. 341 Providing And Fixing 1St Quality Ceramic Glazed Tiles With Minimum Thickness 5Mm Of Approved Make Like Kajaria, Somany Etc. Over 12Mm Thick Cement Mortar In 1:3 Mix. 342 Providing And Laing / Fixing Ceramic Glazed Floor Tiles 300X300mm Of 1St Class Of Somany Or Kajaria Or Equilent Made Laid On 20Mm Thick Bed Of Lcement Mortar In 1:4 Mix. 343 Providing And Fixing Water Closet Squarting Pan ( Indian Type With 100Mm Sand Cast Iron P Or S Trap, 10 Lit, Low Level Pvc Flusingcistern Including Flushing Pipe And Making Good The Walls And Floors Wherever Required ( Orrisa Pattern With Intergral Foot Type ) . 344 Providing And Fixing Salem Stainless Steel Kitched Sink. Size 610X510x200mm 345 Providing And Fixing Of Pvc Wasit Pipe Sink Including Pvc Waist Fititng Complete ( Flexable 40 Mm Dia = 1 No ) 346 Providing And Fixing Of Sanitary Fititng 347 Structual Steel Works Welded In Built Up Section, Trusses And Framed Works Including Cutting Hoisting, Fixing In Position And Applying Priming Coat Of Approved Steel Primer Complete. 348 Providing And Fixing Corrogated G.S Sheets Including Vertical / Curved Surfaces With Polymer Coated J Or L Hooks ( 0.63 Mm Thick ) 349 Proving Ridge Or Hip Of Width 60Cm Over All With Plain Gs Sheets Fixed With Polymer Coated J Or L Hoors ( 0.63 Mm Thick ) 350 Providing And Fixing Of Ms Eves Boarding 300 Mm Wide And Soft Boarding Including Primping Coat Of Red Opxide And Painting With Two Or More Coats With Synthetic Paint Of Approved Brtand And Manufacture Complete Job 351 Providing And Applying White Cement Based Putty Of Approved Thickness 1Mm Of Approved Brand And Manufacture Over The Plastered Surfaces To Prepare The Surface Smooth And Even Complate. 352 Distempering Lwith 1St Quality Acrylic Distemper Of Approvedbrand And Manufacture Including Applyingadditional Lcoats Whereever Required To Achive Even Shade. ( Two Coats ) 353 Finishing Walls With Water Proofing Cement Paint Of Required Shade ( External ) ( Snowsum ) 354 Painting With Synthetic Enamal Paint Ofapproved Brand And Manufacture Of Required Colour To Give Even Shade Two Or More Coats On New Work Includingpriming Coat Of Approved Brand And Manufacture.On Wood Work 355 Add. Provision For Plumbing , And Electrification And Iron Grills To Windows To The Quarter. ( Ls ) 356 Carriage Of Material From Source To Dumping Site At Road By Mechanical Transport A ) Cement And Steel For Average Lead Of10 ( Km ) 357 B ) Sand For Average Lead Of 25 ( Km ) 358 C ) 20Mm Aggregate For Average Lead Of 25 ( Km ) 359 D ) 40Mm Aggregate For Average Lead Of 25 ( Km ) 360 E ) Bricks For Average Lead Of25 ( Km ) 361 F ) Quarry Stone For Average Lead Of25 ( Km ) 362 G ) Soling Stone For Average Lead Of10 ( Km ) 363 Extra Carriage Of Material From Dumping Site Actual Site By Mannual Labour.A ) Cementfor Average Lead Of 300 ( Mts ) 364 B ) Steel For Average Lead Of 300 ( Mts ) 365 C ) Sand & 20Mm Agg. For Average Lead Of300 ( Mts ) 366 D ) 40Mm Agg. For Average Lead Of300 ( Mts ) 367 E ) Bricks For Average Lead Of 300 ( Mts ) 368 F ) Quarry Stone For Average Lead Of300 ( Mts ) 369 G ) Soling Stone For Average Lead Of 300 ( Mts ) 370 05. ( Part A ) Wss Nowgam Nard ( Adv. Cost Rs. 47, 61, 689 / - ) 371 Supply, Installation, Testing & Commissioning Of Submersible Pumping Unit As Per Is 8034 With Following Specification Are As Under:Pump: Discharge :8000Gph , Head-140 M , Efficiency= Not Less Than 50%Speed= 2900 Rpm Type Of Pump= Mixed Flow. Type Of Fluid To Be Handled = Clear Watermaterial Of Construction: Impeller= Stainless Steel Pump Shaft= Stainless Steel Ss 410. Pump Casing Cast Iron / Stainless Steelimpeller: Impeller Is Of The Enclosed Or Semi – Enclosed Type And Properly Balanced.Enclosed Impellers Equipped With Seal Rings On Their Hubs. Coupling: A Suitable Coupling Arrangement Provided With Pump Set. Non Return Valve: - Non Return Valve Of The Suitable Size Provided Above The Pump Discharge Case.Motor:- Method Ofstarting = Star – Delta Speed = 3000 ( Sync ) . Frequency= 50 ± 3 % Hz Working Voltage = 380-415 ± 15% V, 03 Phase Efficiency = Not Less Than 90%Rating=Suitable For Above Parameters Class Of Insulation=F / Suitable For Above Parameters E.Note: Providing Of Test Certificate & Characteristic Curve Of Pumping Equipment Is Compulsory And Pumping Unit Is To Be Approved From The Concerned Sub Divisional Office Before Procuring. Motor Rating :30 Hp 372 Providing / Supplying And Fitting Of G.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class Bconfirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make.Flanges ( As Per Is 6392 / 1997 Table:17 ) Thickness Shall Conform To Is 6392 Part 1St Table-17. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint. Welding Electrodedc Arc Welding Using Welding Electrode Having Diameter Not Less Than 4Mm. Nuts And Bolts Nuts And Bolts ( Conforming To Is:1363 Part 1St ) Rubber Insertion Gaskets Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. The Main Technical Specifications Of The Pipe Are Given Here Under:Dn 100C ( Medium ) Pipe 373 Earth Work In Excavation Required For Installation Ofgantry Mechanismand Associated Worksby Manual Means In Trenches For Foundation , Drains , Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts , Wells , Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed In All Kinds Of Soil. 374 Filling Available Excavated Earth In Trenches, Plinth, Sides Of Foundation Etc.In Layers Not Exceeding 20 Cm In Depth , Consolidating Each Deposited Layer By Reaming And Watering , Lead Upto 50 M And Lift Upto 1.5M.Quantity : 90% Of Item No: 04 375 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .The Body And Bonnent Of The Valve Shall Be Of Ductileiron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valve Shall Be Compatible For Buried Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positionsrest Specification As Per Cluase 12Of Sbd.100 Mm 376 Proproviding And Fitting Ofductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approved For Drinking Water ) .Rest Specification As Per Cluase 13Of Sbd.100 Mm 377 Fabrication, Providing And Fitting Of Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. ( 01 Pair ) Size: 80 Mm 378 Fabrication, Providing And Fitting Of90-120 Degree Bend / Elbowto Be Fabricated Out Of80mm Diameter Class-C, G.I Pipe, 1 M Lengthand Flanged On Both Ends Andto Make It Leak Proof. The Flanges Shall Be M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) And Welded On Both Sides. The Job Includes Nuts, Bolts, Gaskets Etc As Per Site Requirement.100 Mm C 379 Cutting Of Hot Dip Galvanized G.I, C-Class Pipe Across The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Also Includes Providing And Welding Of M.S Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17.:Rest Specification As Per Cluase 11Of Sbd. 100 Mm 380 Fabrication, Providing, Fitting T- Junction Out Of 1 Mtr Of Pipe With Length Of1 Ft Each Arm The Job Includes All Types Of Skilled Labours, Arrangement Of Power Supply / Diesel Generator Set Etc Required For The Job Including P / F Of Suitable Size Nuts Bolts And R.I Gasket In The Flanged Jointsrest Specification As Per Cluase 09Of Sbd 100 Mm 381 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 382 Earth Work In Excavation Required For Installation Ofgantry Mechanismand Associated Worksby Manual Means In Trenches For Foundation , Drains , Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts , Wells , Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed In All Kinds Of Soil. 383 Providing And Laying Of Soling Stone 384 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering . All Work Upto Plinth Level With 1: 2 : 4 Mix ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) 385 Centering And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For Foundation , Footings , Bases For Columns 386 Painting Of The 2 No. Gantry And Plate Form Of Wellusing One Coat Of Red Oxide Metal Primer And Two Coats Of Enamel Paintof Different Shades 387 Providing, Installation Andtestingof Manual Type Triple Spur Gear Chain Pulley Block Along With Monorail Gearedtravelling Trolleyhaving Following Features Gears:- The Hoist Shall Have Precision Machine Case Hardened Alloy Steel Gear Mounted On Bearings And Housed In A Dust Proof Gear Box. The Lubrication Of Gears Should Be Of High Viscosity And Temperature For Longer Life Of Gears. Load Chain:-The Load Chain Be Made Of High Tensile Alloy Steel Having Wear Resistance And Greatest Mobility.Rest Specification As Per Cluase 24Of Sbd.2 Ton 388 Fabrication, Providing And Fitting Ofmodularmotor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories Mu-G 40 Rest Spacification As Per Clause 43-------------- Of Sbd 389 Providing, Fitting, Testing And Commissioning Of 50 Kva Voltage Stabilizeras Per Specifications Below: Type Of Voltage Controller: Manually Operated Copper Wound, 3-Phase, Ac Power Supply Multi Step.Type Of Regulator: Double Plate Type With Electrolytic Copper Contacts.Input Voltage : 250-400 Volts. ( 3 Phase ) Output Voltage : 400 ±10% Volts.Frequency : 50 ±3 C / S.Windings : Electrolytic Grade Copper Of Adequate Section, Vacuum Impregnated And Oven-Dried.Rest Spacification As Per Clause 44 Of Sbd 390 Providing And Fitting Of 2 Core, 3 Core, 3.5-Core, Xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming To Is: 7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc.Rest Specification As Per Cluase 71Of Sbd.50 Sqmm, 3.5 Core L.T 1.1 Kv 391 Providing And Fitting Of 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) –1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. The Main Specification Of The Cable Is Given Below:Rest Specification As Per Cluase 47Of Sbd.16 Sqmm 392 Providing And Fitting Ofpvc Iinsulated Copper Cable As Per Is 694-Along With Thimbling As Per Requirmentsrest Specification As Per Cluase 67 Of Sbd.16 Sq.Mm 1 Core Lt 1.1 Kv 393 P / I Of Earthing Station For Electric Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards. Safe Earthing Electrode Size:80 Mm Dia , Length:2000 Mmback Fill Compound :30 Kg 394 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mm Wide, Thickness 3Mm With 70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items.1 ) 3 Way Terminal Connector 20 Amp.2 ) 3 No Mcb 8 Amp. Rest Specification As Per Cluase 50Of Sbd. 395 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole Vide Item No.36 Having Following Specs:Input: 90-240 V 50 Hzpower Factor: >0.9Colour Temperature: 4K - 6.5Kbeam Angle: 120° - 170° Lumens: >12000Operating Temperature: -20°C To 60°Crest Specification As Per Cluase 51Of Sbd. 396 Providing And Fitting Of 2 Core, 3 Core, 3.5-Core, Xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming To Is: 7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc. Rest Specification As Per Cluase 71Of Sbd.10 Sqmm 2Core Lt 1.1 Kv 397 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer With Input Voltage 70-240 V And Output 220 V. The Stabilizer Shall Be Installed And Connected To The Electric Circuit As Per Location Provided By Site In Charge. 398 Supply , Installation , Commissioning And Creation Of Pole Mounted, Outdoor Type Electric Sub Station As Per The Technical Specifications Given Here Under -Specifications Conforming To Is: 1180 ( Part 1 ) 2014 With Latest Amendments. Type: Ht / Lt Transformer Type Of Cooling:Onan. Operating Conditions:Input=11000 Voltsoutput =433 Volts Ac Supply In 3- Phase.Terminals:Input=3 No. Ht Bush Rods With Insulators, Washer, Nuts Etc.Output=4 No. Lt Bush Rods Switch Insulators, Washers, Nuts Etc.Core: The Core Shall Be Of High Permeability To Reduce Core Losses And The Strips Shall Be Of Suitable Size And Gauge. Transformer Coils: Suitable Number Of Ht And Lt Coils In Each Leg Of The Core. The Transformer Coils Shall Be Fabricated Out Of Superior Quality Aluminum Wire / Strips, Properly Wound. The Ht Transformer Is Completely Filled With Suitable Grade Transformer Oil Up To Required Level. The Job Includes Carriage, And All Leads And Lifts Involved.The Ht Transformer Shall Be Of Reputed Make From An Iso Certified Company As Per Relevant Standards And A Test Certificate Shall Be Provided Before Installation. The Transformer Shall Also Be Provided With Breather Fill With Silica Jel Crystals, Conservator With Oil Level Indicator, Explosion Vet And Adequate Radiator Fins / Tubes. The Impedance Of Transformer Shall Be As Per Is: 1180 ( Part 1 ) 2014 With Latest Amendments.Note: The Scope Of The Work Shall Include Obtaining Of Necessary Inspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificate.Rating: 63 Kva 399 Providing And Fittingg.I Channel / Angle / Flat Of Sizes Including Clamps 400 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Ofht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Rated Voltage 11Kv 200A Complete As Per Is Specs. 401 Supply, Installation, Testing And Commissioning Of 11Kv Polymer Fuses Set Horn Gap 3-Phase 200 A Suitable For Vertical Installation 402 Supply, Installation, Testing And Commissioning Of Gapless Surge Arrestor Station Class, 10Ka, 9Kv, La With Polymer Housing, Station Type 403 Supply And Fitting Of 11 Kv Polymeric Composite Pin Insulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative , Creepagedistance 320 Mm 404 Supply, Installation, Erection Of 9 Mtrs Longh.T Pope Of Specifications St- 410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories .Wherever Required The Job Further Includes G.I Wire Earthing Of Pole As Per Rec Standard. 405 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement 406 Earth Work In Excavation Required For Installation Ofgantry Mechanismand Associated Worksby Manual Means In Trenches For Foundation , Drains , Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts , Wells , Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed In All Kinds Of Soil. 407 Providing And Laying Of Soling Stone 408 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering . All Work Upto Plinth Level With 1: 2 : 4 Mix ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) 409 P / F Danger Plate With Clamps 410 Providing And Fixing G.I Barbed Wire For Anti-Climbing / Anti-Climbing Devices 411 Providing And Fitting Of Pg Clamps 412 Providing And Fitting Of Galvanized Stay Set With 50 X 8 Mm Stay Clamp , Guy Insulator ( 2No. ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts , 2 N0- Turn Buckle , 1.8 M Long , 16 Mm Diameter Solid G.I Stay Rod & 7 / 3.15 Mm Dia. G.I Stranded Wire Complete. 413 Painting Of Poles Red Oxide 414 Painting Of Poles Aluminum Paint 415 Providing And Fitting Of Acsr As Per Is 398 ( Part-2 ) 1996 For 50 Sq.Mmacsr ( Galvanised Steel Reinforced ) For Fitment Of Various Accessories 416 Supply, Installation, Testing Of 35 Sq Mm Xlpe Ht Cable ( Abc Type ) Of 11 Kv Grade With Following Specifications Size Cross Sectional Area In Squre Mm ) =3X35 Phases Red, Yellow , Blue 417 P / F Of 11 Kv Cable Termination Kit For Connecting 35 Sq Mm Xlpe Cable ( Abc Type ) With The Existing Ht Line Near Tapping Point And Ht Transformer. 418 Providing And Fitting Of Lt Distribution Box For H.T Transformer With Mccb For Incomer And Sfu For Outgoing Circuits. 63 Kva 419 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover.With 2-Core 4 Mm2 Cu ( 25 M ) Wiring As Per Site Requirement Along With Other Accessories Like Ss-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 420 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: -Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide.The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 421 Tool Kit For Maintenance: -The Tool Kit For Maintenance Shall Comprise Of The Following And All The Items As Mentioned Below Shall Be Ofproviding Of Tool Kit Consists Of Following Items I. Double Ended Spanner ( Chrome Plated ) 02 Sets Completeii. Double Ended Ring Spannerschrome Plated02 Sets Completeiii. Allen Key Set Black Finish 02 Sets Completeiv. Combination Pliers Insulated With Thick C.A Sleeve; Size In Mm 165, 210, 255Each – 02 No.V. Long Nose Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205Each – 02 No.Vi. Side Cutting Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205 Make – 02 No.Vii. Insulated Screw Drivers Blade Length In Mmblade Dia. In Mmtip Dimensions In Mm Quantity 50 3 1.6 X 0.4 0275 3 1.6 X0.4 02100 3 3 X 0.4 02125 3.5 3.5 X 0.502150 3.5 3.5 X 0.5 02200 4 4 X 0.6 02300 5 5 X 0.8 02Viii. Hammer With Handle Weight – 110 Mg, 340 Gm , 600 Gm –Each – 1No. . Ix. Heavy Duty Pipe Wrench Length In Mm - 200, 300, 600 Each – 01 No.X. Electric Multimeter=1Noxi. Digital Multimeter – 1No.Xii. Digital Clamp Tester Capable To Measure Up To 400A - 1 No.Xiii. Hack Saw Frame With Hack Saw Blade – 01 No.Xiv. S-16 Mxl, S- 16 H X L Socket Set ( 19 Sockets + 6 Accessories ) – 01 No. 422 A ) Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’Siv ) Single Bed Warm Blankets With One Sided Fur- 02 No’Sthe Filling Material For Mattress, Quilt And Pillow Shall Be Of Good Quality Cottonb ) The Job Also Includes Providing Of Pressure Cooker 5Ltr 02 No’S, Steel Patella ( Utensil ) 5Ltrs 02 No’S, Cooking Heater 01 No., Room Heater 01 No., Steel Buckets 10 Litre Capacity 01 No., Plastic Bucket 10 Litre Capacity With Mug 02 No’S Each, Steel Glasses 06 No’S, Steel Plates With Large Spoons And Bowls 03 No’S Each, Cup And Saucer Set ( 01 No. Set ) And, 5Kg Gas Cylinder With Burner / Stove. The Job Also Includes Providing Of Thermo-Cool 15’X12’ Along With Excel Matting Of 15’X12’ Size. The Job Also Includes Providing Of Unbreakable Plastic Chair Table Set Consisting Of Chairs 04 No’S, Extra Heavy Table 01 No. The Job Also Includes Providing Of Good Quality Safety Door Locks ( 03 No’S ) Of Godrej, Link Locks, 423 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply. 424 Providing Of Bamboo Ladders 18 Feet Long Along With 15 Feet Long Link Rods And Ht Glove Pair ( 01 No Each ) 425 Providing Of 1 Kw Heat Convector For Operators For Winter Season 426 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipment Installed At Site Of Appropriate Sizes. 427 Providing, Installation, Testing & Commissioning Of 415 ±10%V ( Output ) , 3 Phase Air Cooled / Water Cooled Diesel Generator Set As Per Is 8528 ( 2018 ) And Iso 3046 ( 2002 ) For Engine And Iec / Is 60034-1 For Alternator Suitably Assembled And Fitted In A Pollution Free Acoustic Enclosure / Canopy Of Required Size As Per Ministry Of Environment Protection Rule 1986 Read With Latest Amendments. The Dg Set Is Required To Be Fitted And Tested On Load At Sitethe D.G Set Shall Have The Following Technical Specification.Besides The Above Works The D.G Set Shall Be Provided With 12 V, 150 Ah Lead Acid Battery Of Reputed Make Fitted Inside The D.G Set Canopy Along With Necessary Accessories And Battery Charger Of Required Capacity. The Job Also Includes The Cost On Account Of Hsd And Skilled Operator Required For Operation Of D.G Set For A Period Of 10 Hours Continuously During Its Testing And Commissioning Of D.G Set At Site. The Capacity Of The D.G Set Is Given Below:Rating:50 Kva Dg Set 428 ( Part B ) Pump House Of Wss Nowgam Nard ( Adv. Cost Rs. 19, 47, 322 / - ) 429 Earth Work In Excavation Over Areas Exceeding 30 Cm And Upto 1.5 M In Depth 1.5 M In Width As Well As 10 Sqm On Plan Inculding Disposal Of Excavated Soil Upto1mt From Cutting Edge. 430 Extra For Earth Work For Every Additional Lift Of 1.5 M Or Part Thereof 431 Supply And Filling Of Gsb Boulders Including All Leads And Lifts 432 Providng And Laying In Position Cement Concrete Of Specified Grade Exlcuding The Cost Of Centring And Shuttering- All Work Up To Plinth Level 1:4:8 ( 1 Cement:4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size 433 Providing And Laying In Position Specified Grade Of Rcc ( 1:2:4 ) Mix Using 20 Mm Aggregates Inlcld. Curing Complete Job 434 Providing And Laying In Position Specified Grade Of Excluding The Cost Of Centring And Shuttering - All Work Up To Plinth Level. 1:3:6 ( 1 Cement:3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size 435 R.R. Masonary With Quary Stone Laid In Dry. Using Quarry Stone With Bond Stone 436 Brick Work With Ommonlybrunt Clay F.P.S Bricks Of Class Designation 75 In Foundation And Plinth In 1:6 Cm. 437 Extra Over Brick In Super Structure Up To Floor V Level. 438 Providing Wood Work In Frames Of Doors , Windows Clerestorywindows And Other Frames , Wrought Framed And Fixed In Position With Hold Fast Lugs Or With - Dash Fasteners Of Required Dia And Length ( Hold Fast Lugs Or With Dash Fasteners Shall Be Paid For Saperately ) : Kail Wood. 439 Providng And Fixing Of Glazed Shutters For Doors, Windows And Clerestory Windows Using 10 Kgs / Sqm ( 4 Mm Thick ) Float Rate Of Thickness Of Glass Panes Including Isi Marked Ms Prssed Butt. Shutters In Mm Per Sqm Hinfes Bright Finsiehd To Requried Size With Necessary 35X30 Screwskail Wood. 440 Providing And Fixing 35 Mm Thick Wire Gauze Shuttersusing Galvanised M.S. Wire Gauze Of Average Width Foraperture 1.4 Mm In Both Directoin With Wire Of Dia. 0.63 Mm For Doors, Windows And Clerestory Windows With Hinges And Necessary Screws :Kail Wood. 441 P / F Of 40X5mm Hold Fasts Incld. Fixing In 1:3:6 Mix. 442 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Upto 15°, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Upto Floor Five Level Excluding The Cost Of Centring, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm N / S Stone Aggregate. 443 Providing Reinforcement To The Rcc Works Including Bending, Binding, Cutting Placing In Position Complete. 444 Centering And Shuttering Including Proping, Struting Etc And Removal Of Farm Work. ( A ) Lintel Band & Beam 445 ( B ) Suspended Floors ( Slab ) 446 ( C ) Foundations / Bases Of Columns. 447 Cement Concrete Flooring 1:2:4 ( 1 Cement: 2 Coarse Sand .: 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete.50Mm Thick. 448 A ) 20Mm Thick Cement Plaster In 1:4 Nominal Mix. 449 B ) 6Mm Thick 1:3 Mix With Floating Coat In Septic Tank 450 Providing And Fixing Salem Stainless Steel A Lsi 304 ( 18 / 8 ) Kitchen Sink As Per I.S. 13983 With C.L. Brackets And Stainless Steel Plug 40 Mm Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Whereverrequired:. Size 610X510x200mm 451 Providing And Fixing Water Closet Squarting Pan ( Indian Type With 100Mm Sand Cast Iron P Or S Trap, 10 Lit, Low Level Pvc Flusingcistern Including Flushing Pipe And Making Good The Walls And Floors Wherever Required ( Orrisa Pattern With Intergral Foot Type ) . 452 P / Fist Quality Ceramic Glazedtilesconfirming To I. S : 13753 Of Minimum Thickness 5Mm Of Approved Make Likenitco, Orient, Somany, Kajaria Etc.In All Colours, Shades Except Begundy, Bottle Green , Black Of Any Size As Approved By Engineer -In -Charge In Skirting, Risers Of Steps And Dados , Laid On 12Mm Thick Bed Of Cement Mortar ( 1 : 3 ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing The Joints With White Cement Mixed With Pigment Ofmatching Shade Complete. 453 Providing And Applying White Cement Based Putty Of Approved Thickness 1Mm Of Approved Brand And Manufacture Over The Plastered Surfaces To Prepare The Surface Smooth And Even Complate. 454 Providing And Applying Priming Coat With Ready Make Pink Or Grey Primer Of Approved Brand And Manufacture 455 Painting With Synthetic Enamal Paint Ofapproved Brand And Manufacture Of Required Colour To Give Even Shade Two Or More Coats On New Work Lincludingpriming Coat Lof Approved Brand And Manufacture. 456 Provision For Sanitary Fittings And Water Supply Installations Viz. Bib Cocks, Towel Rod, G.I Pipe Fittings, Pvc Disposal Pipes Including Manholes, Mirror, Cistern, Commode, 50Lt Capacity Geyser, Sinketc. Water Storage Tank Triple Layer 1000Lt Capacity Etc Complete Job As Per The Directions Of Engineer In Charge. ( Ls ) 457 Providing, Hoisting And Fixing , Trusses, Purlins, Rafters, Using Ist Class Poplar Wood 458 Providing And Fixing Of Corrogated G.S. Sheets Including Vertical / Curved Surfaces With Polymer Coated J Or L Hooks ( 0.50Mm Thick ) . 459 Providing Ridge Or Hip Of Width 60Cm Over All With Plain G.S. Sheets Fixed With Polymer Coated J Or L Hooks ( 0.50Mm Thick ) . 460 Providing And Fixing Ofeves Boarding 0.50Mm Thick 461 Providing And Fixing Ofcoloured Gs Sheets As Soffit Boarding 462 Provision For Ornamental Ms Grill In Window Frames . 463 Distempering With 1St Qualiyt Arcylic Distemper Of Approved Brand And Manufacture Including Applying Additional Coats Where Ever Requried To Achieve Even Shade ( Two Coats ) 464 Provision For Providing And Fixing Pvc Conduitsof Standard Make For Electric Fiting Including Electric Fittings Jusing Wire And Other Electric Installations Of Standard Make Including McbS And Main Control Board And Service Wire Complete Job Lighting Poingts 6 No Heating Poingt 4 No ( Ls ) 465 Dismentling Of Exisitng Old And Damaged Pump Operator Quarter Incld. Stakng Of Serviceable Material And Disposal Of Unserviceable Material As Per Directions Of Engineer Incharge. The Dismantled Material So Retrieved From The Structure Will Be The Property Of Executing Agency. ( Ls ) 466 Carriage Of Material From Source To Dumping Site At Road By Mechnical Transport.A ) Cement And Steel For Average Lead Of30km 467 B ) Sand For Average Lead Of50 Km 468 C ) 40 Mm Aggregate For Average Lead Of 50 Km 469 D ) 20 Mm Aggregate For Average Lead Of 50Km 470 E ) Bricks For Average Lead Of 16 Km 471 F ) Quarry Stone For Average Lead Of05 Km 472 Extra Carriage Of Material Fromdumping Site To Actual Site Of Work A ) Cementfor Average Lead Of 500M 473 B ) Steel For Average Lead Of500 M 474 C ) Sand 20 Mm Aggregate For Average Lead Of 500 M 475 D ) 40 Mm Aggregate For Average Lead Of500 M 476 E ) Soling Tone For Average Lead Of500 M