| 1 | Earth work in excavation by mechanical means(hydraulic excavator)/manualmeans over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 3 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering1:4:8 ( 1 Cement: 4 fine sand : 8 graded stone aggregate 40 mm nominal size) |
| 5 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 6 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement: Work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, In plinth and skirting courses, fillets, columns, pillars, posts and strutsfinishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-RCC work in suspended floors, roofs having slope upto 15° landings, balconies, shelves and chajjas.1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level: Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars. |
| 10 | Centering shuttering including struttings, propping etc. and removal of form work for: |
| 11 | i)Foundations, footings, bases for columns etc. for mass concrete with timber plank. |
| 12 | ii)Suspended floors, roofs, landings, balconies and access platform with 12mm thick shuttering ply |
| 13 | iii)Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 14 | iv)Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 15 | First class brick work in foundation and plinth including cost of all materials as required complete.In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 16 | Half brick masonry with first class bricks in foundation and plinth including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 17 | Extra for providing & placing in position 2 nos 6mm dia MS bars at every 4th course ofhalf brick masonry work including anchorage in joints of 75mm in each side in superstructure for all levelincluding cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 18 | Providing and fixinggang saw cut of approved thickness mirror polished, premoulded and prepolished machine cut for kitchen platforms,vanity counters, window sills, facias and similar locations of required sizeapproved shade,colour and texture laid over 20 mm thick base of cement mortar1:4 (1 cement:4 fine sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups in/c rubbering,curing moulding and polishing to edges to give high gloss finish etc. complete all levels.18 mm granite of any colour and shade duly approved:-Area of slab over 0.50 sqm. |
| 19 | Providing edge moulding to approved thickness marble stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete at all levels as required as per design approved by the Engineer-in-charge:-18 mm granite work. |
| 20 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 21 | Providing and fixing 1mm thick MS sheet door with frame of 40mmX40mmX6mm angleiron and 3mm M.S gusset plates at junction and corners ,& withcleats with bolts &nuts ,rivets ,locking arrangement ,handles ,hooks&eyes ,pinels including embedding in cement concrete of required grade for fixing in position ,all necessary fittings ,including applying a priming coat of aprroved steel primer erc. complete as required.i)Using M.S angles 0f 40X40X6mmfor diagonal braces. |
| 22 | Steel work in built up tubular (round,square or rectangular hollow tubes etc.) , trusses etc, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer ,including welding and bolted with special shaped washers etc. complete.i)Hot finished welded type tubes |
| 23 | Supply & installation of pre-painted Galvalume sheets for roofing/cladding (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) in 550mpa steel grade, made out of Cold Rolled Steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to ASTM A792/A792M and AS1397, Alloy coating AZ150/AZ70, colour coated with high quality Polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micronon both side. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in singlelength upto 12 metre or as desired by Engineer-incharge.The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55mm) with EPDMwashers filled with white lead complete upto anypitch in horizontal/ vertical or curved surfacesexcluding the cost of purlins, rafters and trusses andincluding cutting to size and shape wherever required.i)0.50mm thickness. |
| 24 | Providing and fixingMarble stone in floors over 20 mm thick bed ofcement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with of matching shade, including rubbing and polishingcomplete:- (i) 18 mm thick Marble stone:-- Raj Nagar plain marble. |
| 25 | Tile work in skirting ,risers of steps and dado up to 2m height over 12mm heightover 12mm thick bed of cement mortar 1:3(1 cement:3 fine sand) and jointed with grey cement slurry @3.30 kg/Sqm ,in/c pointing in white cement mixed with pigment of matchingshade complete.(i) 8mm thick Rajnagar marble tiles (polished) |
| 26 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 ( thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1 : 3 ( 1 cement : 3 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete. |
| 27 | 12 mm cement plaster of mix:- (i) in cement mortar 1:4(1 cement:4 fine sand) |
| 28 | Neat cement punning |
| 29 | Distempering with oil bound washable distemper of approved brand and manufacture and of required shade on new work ( two or more coats ), over and including a priming coat of cement primer to give an even shade complete |
| 30 | Finishing walls with premium acrylic smooth exterior paint of required shade of approved brand and manufacture on new work ( two or more coats applied @ 1.43 kg/10 sqm ) over and including base coat water proofing cement paint applied @ 2.20 kg/10 sqm complete. |
| 31 | Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel, galvanised iron / steel work. |
| 32 | Providingandfixingaluminiumworkfordoors,windows,ventilators and partitions withextrudedbuiltupstandardtubularsections/ appropriateZsectionsandothersectionsofapprovedmake conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawingandthedirectionofEngineerincharge.(Glazingand paneling and dash fasteners to be paid for separately) :-.(i) For fixed portion of approved quality:- - Anodisedaluminium(anodisedtransparentordyedto requiredshadeaccordingtoIS:1868,Minimumanodic coating of grade AC 15). |
| 33 | Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board grade-I, type II conforming to IS : 12823 bonded with phenol formaldehyde synthetic resin, of approved brand and manufacture in panelling fixed in aluminium doors, windows, shutters and partition frames with C.P. brass / stainless steel screws all complete as per architecturaldrawing and the direction of Engineer-in-charge.i)Prelaminated particle board of approved quality with decorative lamination on one side and balancing lamination on other side. |
| 34 | Steel work welded in builtup section/framed work in/c cutting ,hoisting ,fixing in position and applying a priming coat of approved steel primier using steel etc .complete as requiredIn gratings frames ,guard bar ,ralling ,bracket ,gates and similar work all complete. |
| 35 | Providing and fixing glazing of approved quality in aluminium doors,windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :-with float glass panes of 4.00 mm thickness(weight not less than 10.00 kg/sqm) |
| 36 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :e i)White Vitreous China Flat back wash basin size 630x450 mm with single 15 mm C.P. brass pillar tap. |
| 37 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required:610x460 mm bowl depth 200 mm. |
| 38 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipei)32 mm dia |
| 39 | Providing and fixing C.P. brass long body bib cock ofapproved quality conforming to IS standards andweighing not less than 690 gms.i)15mm nominal bore. |
| 40 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion |
| 41 | i)Single socketed pipe - 75 mm OD |
| 42 | ii)Single socketed pipe - 110 mm OD |
| 43 | ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solventcementandthecost ofcuttingchases andmaking goodthe same including testing of joints complete as per direction of Engineer in Charge. - internal work-Exposed on wall25 mm nominal outer dia pipes |
| 44 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):25 mm nominal bore |
| 45 | Painting with synthetic enamel paintof approved brand and manufacture of required colour to give an even shade (Payment shall be made after submission of test certificate issued by the Manufacturer)Twoor more coats on new work] |