Setting Up Of Real Time Data Acquisition System, Hydro Modelling Flood Control Room At Ezhilagam And Flood Monitoring Centres For Water Resources Department Headquarters At Chepauk And Four Collectorates Setting Up Of Real Time Data Acquisition System, Hydro Modelling Flood Control Room At Ezhilagam And Flood Monitoring Centres For Water Resources Department Headquarters At Chepauk And Four Collectorates , I Field Equipment Arg Locations With Gprs / Gsm- 63 Locations , Arg Sensor With Required Accessories And Mounting Setup As Per Technical Specification No: 8.1, 8.6.1, 8.8.1 , Soil Moisture Probe With Required Accessories And Mounting Setup As Per Technical Specification No: 8.2, 8.6.1, 8.8.1 , Civil Works As Per The Drawing No: Cfm-Arg , Installation, Testing And Commissioning , Arg Locations With Gprs / Gsm And Vsat- 23 Locations , Arg Sensor With Required Accessories And Mounting Setup As Per Technical Specification No: 8.1, 8.6.1 8.6.2, 8.8.1 , Soil Moisture Probe With Required Accessories And Mounting Setup As Per Technical Specification No: 8.2, 8.6.1 8.6.2, 8.8.1 , Civil Works As Per The Drawing No: Cfm-Arg , Installation, Testing And Commissioning , Aws Locations With Gprs / Gsm- 2 Locations , Aws With Gsm / Gprs Mode Of Transmission As Per Technical Specification No: 8.4, 8.6.2, 8.8.2 , Civil Works As Per The Drawing No: Cfm-Aws , Installation, Testing And Commissioning , Aws Locations With Gprs / Gsm And Vsat- 6 Locations , Aws With Gsm / Gprs And Vsat Mode Of Transmission As Per Technical Specification No: 8.4 &8.6.1, 8.6.2, 8.8.2 , Civil Works As Per The Drawing No: Cfm-Aws , Installation, Testing And Commissioning , Awlr ( Se ) Locations With Gprs / Gsm In Existing Gauge Well- In 76 Waterbody Locations , Awlr With Shaft Encoder Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.1, 8.6.1, 8.8.1 , Civil Works As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( Se ) Locations With Gprs / Gsm, Vsat In Existing Gauge Well- In 2 Waterbody Location , Awlr With Shaft Encoder Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity, As Per Technical Specification No: 8.3.1, 8.6.2, 8.8.1 , Civil Works As Per The Drawing Numbers In Annexure- Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( Se ) Locations With Gprs / Gsm In New Gauge Well- In11 Waterbody Locations , Awlr With Shaft Encoder Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.1, 8.6.1, 8.8.1 , Civil Works For New Gauge Well As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) Locations With Gprs / Gsm, New Frame And Radar Based System- In 7 Waterbody Locations , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity, As Per Technical Specification No: 8.3.2, 8.6.1, 8.8.1 , Required Civil Works For New Frame Structure, As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) Locations With Gprs / Gsm, In New Frame And Radar Based System- In 16 Waterway Locations , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity, As Per Technical Specification No: 8.3.2, 8.6.1, 8.8.1 , Civil Works For New Frame Structure As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) Locations With Gprs / Gsm, Vsat, New Frame And Radar Based System- In 12 Waterway Locations , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity, As Per Technical Specification No: 8.3.2, 8.6.2, 8.8.1 , Civil Works For New Frame / Box Structure As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( Se ) Locations With Gprs / Gsm Innew Gauge Well- In 4 Waterway Locations , Awlr With Shaft Encoder Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.1, 8.6.1, 8.8.1 , Civil Works ( New Gauge Well ) As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( Se ) Locations With Gprs / Gsm, Vsat In New Gauge Well- In 1 Waterway Locations , Awlr With Shaft Encoder Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity, As Per Technical Specification No: 8.3.1, 8.6.2, 8.8.1 , Civil Works For New Gauge Well, As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) , Aws, Gate Sensor Locations With Gprs / Gsm, Vsat ( 1 No. ) - Chembarambakkam Lake , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity, As Per Technical Specification No: 8.3.2, 8.6.2 & 8.8.2 , Aws With Sensors As Per Technical Specification - Data Logger With Min. 8 Sensor Connectivity As Per Technical Specification No: 8.4, 8.6.2 & 8.8.2 , Gate Sensors ( 24Nos ) With Required Accessories And Mounting Setup - Data Logger With Min. 24 Sensor Connectivity 8.5, 8.6.2 & 8.8.2 , Cctv Camera With Inbuilt Ir Illuminator With Required Accessories And Mounting Setup , Civil Works For Aws , Awlr And Gate Sensors Including Mounting Frame As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) , Aws, Gate Sensor Locations With Gprs / Gsm, Vsat ( 1 No. ) - Poondi Lake , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger Included With Gate Sensory As Per Technical Specification No: 8.3.2, 8.6.2 & 8.8.2 , Aws With Sensors As Per Technical Specification - Data Logger With Min. 8 Sensor Connectivity As Per Technical Specification No: 8.4, 8.6.2 & 8.8.2 , Gate Sensors ( 16Nos ) With Required Accessories And Mounting Setup - Data Logger With Min. 18 ( Iincl 2 For Awlr ) Sensor Connectivity As Per Technical Specification No: 8.5, 8.6.2 & 8.8.2 , Cctv Camera With Inbuilt Ir Illuminator With Required Accessories And Mounting Setup , Civil Works For Aws , Awlr And Gate Sensors Including Mounting Frame As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) , Aws, Gate Sensor Locations With Gprs / Gsm, Vsat ( 1 No. ) - Redhills Lake , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Gate Sensor Connectivity As Per Technical Specification No: 8.3.2, 8.6.1& 8.8.2 , Aws With Sensors As Per Technical Specification - Data Logger With Min. 8 Sensor Connectivity As Per Technical Specification No: 8.4, 8.6.2 & 8.8.2 , Gate Sensors ( 2Nos ) With Required Accessories And Mounting Setup - Data Logger With Min.4 Sensor Connectivity As Per Technical Specification No: 8.5, 8.6.2 & 8.8.2 , Cctv Camera With Inbuilt Ir Illuminator With Required Accessories And Mounting Setup , Civil Works For Aws , Awlr And Gate Sensors Including Mounting Frame As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) , Aws, Gate Sensor Locations With Gprs / Gsm, Vsat ( 1 No. ) - Thervoy Lake , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.2, 8.6.1& 8.8.2 , Aws With Sensors As Per Technical Specification - Data Logger With Min. 8 Sensor Connectivity As Per Technical Specification No: 8.4, 8.6.2 & 8.8.2 , Cctv Camera With Inbuilt Ir Illuminator With Required Accessories And Mounting Setup , Civil Works For Aws And Awlr Including Mounting Frames As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) , Aws Location With Gprs / Gsm, Vsat ( 1 No. ) - Cholavaram Lake , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.2, 8.6.2, 8.8.2 , Aws With Sensors As Per Technical Specification - Data Logger With Min. 8 Sensor Connectivity As Per Technical Specification No: 8.4, 8.6.2 & 8.8.2 , Cctv Camera With Inbuilt Ir Illuminator With Required Accessories And Mounting Setup , Civil Works For Aws And Awlr Including Mounting Frames As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) , Gs Location With Gprs / Gsm - Nandhambakkam Check Dam , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.2, 8.6.1 & 8.8.1 , Gate Sensors ( 14Nos ) With Required Accessories And Mounting Setup - Data Logger With Min. 16 Sensor Connectivity As Per Technical Specification No: 8.5, 8.6.1, 8.8.2 , Cctv Camera With Inbuilt Ir Illuminator With Required Accessories And Mounting Setup , Civil Works For Awlr And Gate Sensors Including Mounting Frames As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) Location With Gprs / Gsm -Feeder Canal Regulator And Kp-Tk Canal Regulator ( 2 Sites ) , Awlr Withradar Based Sensors ( 2 Nos ) With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity ( 1 No ) As Per Technical Specification No: 8.3.2, 8.6.1& 8.8.1 , Awlr With Radar Based Sensor ( 1 No ) With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity ( 1 No ) As Per Technical Specification No: 8.3.2, 8.6.1, 8.8.1 , Civil Works For Awlr Including Mounting Frames As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) , Gs Location With Gprs / Gsm, Vsat ( 3 Nos. ) - Kesavaram Anicut And Two Downstream Bridges ( Three Sites ) , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.2, 8.6.2 & 8.8.1 , Gate Sensors ( 16Nos ) With Required Accessories And Mounting Setup – One Data Logger With Min. 18 Sensor Connectivity As Per Technical Specification No: 8.5, 8.6.2 & 8.8.2 , Civil Works For Awlr Including Mounting Frames As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr Location With Gprs / Gsm - Araniar Anicut , Awlr Withradar Based Sensors ( 2 Nos ) With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity ( 1 No ) As Per Technical Specification No: 8.3.2, 8.6.1, 8.8.1 , Awlr With Radar Based Sensor ( 1 No ) With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity ( 1 No ) As Per Technical Specification No: 8.3.2, 8.6.1, 8.8.1 , Civil Works For Awlr Including Mounting Frames As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( Se ) Aws, Gs Location With Gprs / Gsm, Vsat In New Gauge Well ( 1 No. ) - Korattur Anicut , Awlr With Shaft Encoder Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity – Right Bank As Per Technical Specification No: 8.3.1, 8.6.2 & 8.8.1 , Aws With Sensors As Per Technical Specification - Data Logger With Min. 8 Sensor Connectivity – Right Bank As Per Technical Specification No: 8.4, 8.6.2 & 8.8.2 , Gate Sensors ( 4 Nos ) With Required Accessories And Mounting Setup – One Data Logger With Min. 4 Sensor Connectivity – Right Bank As Per Technical Specification No: 8.5, 8.6.2 & 8.8.2 , Gate Sensors ( 4 Nos ) With Required Accessories And Mounting Setup – One Data Logger With Min. 4 Sensor Connectivity - Left Bank As Per Technical Specification No: 8.5, 8.6.2 & 8.8.2 , Civil Works For New Full Gauge Well And Frame Structures For Awlr As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) Location With Gprs / Gsm , Vsat ( 1 No. ) - Vallur Anicut , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.2, 8.6.2 & 8.8.1 , Civil Works For New Full Gauge Well And Frame Structures For Awlr As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Plank Type ( Gauge Plate ) Water Level Recorders Including Levelling And Fixing On Existing Permanent Structures , Adcp, Float, Gps, Laptop Inclusive Of All Accessories As Per Thetechncial Specification No: 10.1 , Electromagnetic Current Meters Inclusive Of All Accessories As Per Thetechncial Specification No: 10.2 , Ii Control Room ( Hmcr, Ndrc, Fmc ) Equipment A Hydro Modelling Control Room ( Hmcr ) 1 Location -It Components Servers , 4 Cpu Blade Server ( For Hydro Modelling ) With Required License Operating On Microsoft Windows Including Os And Virtualization Software Cost As Per The Technical Specification No:9.5.1 , 2 Processor Blade Server ( For Database ) Operating On Redhat Linuxincluding Os Cost As Per The Technical Specification No:9.5.2 , 2 Processor Blade Server ( For Hosting Web Dss Application, Gis Server, Email Server And Sms Server ) With Required License Operating On Microsoft Windows Including Os And Virtualization Software Cost As Per The Technical Specification No:9.5.2 , Integratedblade Chassis To House All The Blade Servers , Storage And Network As Per The Technical Specification No:9.5.3 , Software , Backup Software- Should Support Full Vm Back And Granular Restore As Per The Technical Specification No:9.13 , Enterprise Management System With License As Per The Technical Specification No:9.8 , Postgresql On Redhat Linux As Per The Technical Specification No:9.15 ( Notional ) , Rtdas Field Equipment System Software At Data Centre As Per Oem Supplier’S Standards , Mike Suite Of Software For Hydro Modelling. Perpetual And Network License With Dongle. ( All Inclusive For 5 Years ) For Mike Hydro Rainfall Runoff, Mike Flood, Mike Hydro River ( Da ) , Mike 21, Mike +, Mike Operation ( All In Latest Version ) , Customization And Integration With 3Rd Party Systems And The Existing System , Gateways , Sms Package For The Department Users For The Entire Project Duration , Sms Package For The Public ( Required During Oct - Dec Every Year ) , E-Mail Gateway , Gis System [ Geoserve For Web Dss And 3 Q-Gis Desktop And 2 Arcgis Pro ( Latest Version ) With Spatial Analyst ] License , Routers , Datacentre Core Router Networked To All Equipment Using Gpon As Per Technical Specification No:9.1 , Firewalls , Internet And Dc Firewall ( Ngfw ) As Per The Technical Specification No:9.4 , Web Application Firewall As Per The Technical Specification No:9.3 , Anti-Advance Persistent Threat As Per The Technical Specification No:9.2 , Epabx + 20 Digital Phones As Per The Technical Specification No: Section – 9.11 , Vsat Components ( Antenna, Support Structure, Vsat Modem / Router ) As Per The Technical Specification No: Section – 9.19 , Ssl Certificates - Wildcard License With Unlimited Sub Domain Support , Installation, Testing & Commissioning Of Hydro Modelling Control Room ( Hmcr ) – It Components , Connectivity , Internet Leased Line Connectivity For Hydro Modelling Control Room With 100 Mbps 1:1 Bandwidth ( 1+1 ) – Installation , Internet Leased Line Connectivity For Hydro Modelling Control Room To Disaster Recovery On Cloud And Hydro Modelling Control Room To Nearline Dr & Fmc With 100Mbps 1:1 Bandwidth ( 1+1 ) - Installation , Satellite Poolbandwidthcharges Annual Recurring Forback Haulcommunication Between Service Provider Hub And Hydro Modelling Control Room @128 Kbps – Installation , Any Other Items Not Specified Above, But Required For The Completeness Of The Objective Of The Hmcr. ( Specify ) , Hydro Modelling Control Room – 1 Location-Non- It Components , Video Wall Solution - 70 In A 3X2arrangementwith Videowall Management Solution As Per The Technical Specification No:9.17 , 70 Led Display Panels As Per The Technical Specification No:9.18 , Computers , Workstations For Hydro Modelling As Per The Technical Specification No:9.9.1 , Desktops – Control Room As Per The Technical Specification No:9.9.2 , Desktops – Adminas Per The Technical Specification No:9.9.3 , Printers , Network Colour Laser Printers ( A3 Size ) As Per The Technical Specification No:9.10.1 , Network Multifunction Printer ( A4 ) As Per The Technical Specification No:9.10.2 , Sat Phone As Per The Technical Specification No:9.12 , Civil Works Including Site Preparation, Fire Rated False Partition, Civil Partition, Floor Tile, False Ceiling, False Flooring, Floor Strengthening, Doors And Painting Works, Plumbing, Etc Complete As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:- 6, 9, 11 , Electrical Cabling, Panels, Db, Earthing, & Necessary Illumination Devices And Fixtures As Per Technical Specification No: 11 , Ip Based Cctv Surveillance System As Per Technical Specification No:11.16 , Fire Alarm System As Per Technical Specification No:11.12 , Fire Suppression System - Gas Based For Sever, Electrical, Ups & Battery Room As Per Technical Specification No:11.10 , Fire Suppression System- Sprinkler Based For All The Other Area As Per Technical Specification No:11.10 , Aspirating Smoke Detection System As Per Technical Specification No:11.13 , Public Address System As Per Technical Specification No:11.17 , Water Leak Detection System As Per Technical Specification No:11.9 , Rodent Repellent System As Per Technical Specification No:11.15 , Access Control System - Biometric And Card Reader With Required Number Of Access Cards As Per Technical Specification No:11.14 , Comfort Ac For All The Other Rooms As Per Technical Specification No:11.11 , Precision Ac For Server Room As Per Technical Specification No:11.11 , Integrated Building Management System Software , Ups Of Adequate Capacity, 80 Kva Minimum, With 30 Min Power Backup For It Components As Per Technical Specification No:9.16 , Ups Of Adequate Capacity, 30 Kva Minimum, With 30 Min Power Backup For Non-It Components As Per Technical Specification No:9.16 , Diesel Genset Of Adequate Capacity. Minimum 250 Kva, With Automatic Transfer, Shelter And Exhaust Setup As Per Technical Specifications No. 11.18 , Networking Cost ( Passive Components Including Cat6 Cables, Ofc, Cat6 & Fiber Patch Cords, Liu, Rj45 Jack Panels Etc. ) , Furniture , Command Centre Desks ( 4 Seater ) As Per Technical Specification No:11.2 , Sys Admin Desks ( 4 Seater ) As Per Technical Specification No:11.2 , Server Storage Desk As Per Technical Specification No:11.2 , Modelling Workstation Desks As Per Technical Specification No:11.2 , Office Desks, Storage Units As Per Technical Specification No:11.2 , Conference Table ( 16 -Seater Arrangement ) As Per Technical Specification No:11.2 , Ergonomic Chairs – Work As Per Technical Specification No:11.2 , Ergonomic Chairs – Waiting As Per Technical Specification No:11.2 , Installation, Testing & Commissioning Of Hydro Modelling Control Room – Non It Components , Any Other Items Not Specified Above, But Required For The Completeness Of The Objective Of The Hmcr. ( Specify ) , Disaster Recovery ( Dr ) On Cloud , Infrastructure As A Service ( Virtual Machines ) Cost For All The Applications And Database ( Hydro Modelling, Web Dss, Mobile App Sever , Gis Server , Postgresql ) For Five Years , Cloud Storage Primary Storage ( Unified ) With Usable Space 50 Tb For All The Applications And Sensor Data Extendable To 200 Tb. 2 Tb Of Standard Storage + Rest Archive Storagefor Five Years As Per The Technical Specifications – Section 9C , Postgresql On Redhat Linux , Rtdas Field Equipment System Software , Customization And Integration With 3Rd Party Systems And The Existing System , Mobile App ( Crowd Sourcing ) Server , Gis System [ Geoserve For Web Dss And 3 Q-Gis Desktop ] License , Ssl Certificates- Wildcard License With Unlimited Sub Domain Support , Installation, Testing & Commissioning Disaster Recovery ( Dr ) On Cloud , Internet Leased Line Connectivity For Disaster Recovery On Cloud To Hydro Modelling Control Room And Disaster Recovery On Cloudto Nearline Disaster Recovery & Fmc With 100 Mbps 1:1 Bandwidth – Installation , Any Other Items Not Specified Above, But Required For The Completeness Of The Objective Of The Dr On Cloud. ( Specify ) , D. Nearline Dr Centre & Fmc At Wrd Hq -1 No ( It - Component ) Servers , 2 Processor Blade Server ( For Database ) Operating On Redhat Linux Including Os And Virtualization Software Cost As Per The Technical Specification No:9.5.2 , 2 Processor Blade Server ( For Hosting Web Dss Application, Gis Server, Email Serverand Sms Server ) With Required Licenseoperating On Microsoft Windowsincluding Os Costas Per The Technical Specification No:9.5.2 , Integratedblade Chassis To House All The Blade Servers , Storage And Network As Per The Technical Specification No:9.5.3 , Software , Backup Software- Should Support Full Vm Back And Granular Restore As Per The Technical Specification No:9.13 , Enterprise Management System With License As Per The Technical Specification No:9.8 , Postgresql On Redhat Linux As Per The Technical Specification No:9.15 , Rtdas Field Equipment System Software , Mike Suite Of Software For Hydro Modelling. Network License With Dongle. ( All-Inclusive For 5 Years At 3 Months Per Year ) For Mike Hydro Rainfall Runoff, Mike Flood, Mike Hydro River ( Da ) , Mike 21, Mike +, Mike Operation. ( All In Latest Version ) . , Customization And Integration With 3Rd Party Systems And The Existing System , Gis System [ Geoserve For Web Dss And 3 Q-Gis Desktop And 2 Arc Gis Pro With Spatial Analyst ] License , Routers , Datacentre Internet Router As Per The Technical Specification No: 9.1 , Firewalls , Internet And Dc Firewall ( Ngfw ) As Per The Technical Specification No:9.4 , Web Application Firewall As Per The Technical Specification No:9.3 , Anti-Advance Persistent Threat As Per The Technical Specification No:9.2 , Epabx + 20 Digital Phones As Per The Technical Specification No:9.11 , Vsat Components ( Antenna, Support Structure, Vsat Modem / Router ) As Per The Technical Specification No: 9.19 , Ssl Certificates- Wildcard License With Unlimited Sub Domain Support , Installation, Testing & Commissioning , Connectivity , Internet Leased Line Connectivity For Ndrc With 100 Mbps 1:1 Bandwidth ( 1+1 ) – Installation , Internet Leased Line Connectivity For Ndrc To Disaster Recovery On Cloud And Ndrc To Hmcr With 100 Mbps 1:1 Bandwidth ( 1+1 ) – Installation , Satellite Poolbandwidthcharges Annual Recurring Forbackhaulcommunication Between Service Provider Hub And Ndrc @ 128 Kbps – Installation , Any Other Items Not Specified Above, But Required For The Completeness Of The Objective Of The Ndrc. ( Specify ) , Nearline Dr Centre & Fmc At Wrd Hq -1 No ( Non-It ) , Video Wall Solution - 70In A 3 X 2Arrangementwith Videowall Management Solution As Per Technical Specification No:9.17 , 70 Led Displays As Per The Technical Specification No:9.18 , Computers , Workstations For Hydro Modelling As Per Technical Specification No:9.9.1 , Desktops – Control Room As Per Technical Specification No:9.9.2 , Desktops – Adminas Per Technical Specification No:9.9.3 , Printers , Network Colour Laser Printers ( A3 Size ) As Per Technical Specification No:9.10.1 , Network Multifunction Printer ( A4 ) As Per Technical Specification No:9.10.2 , Sat Phone As Per Technical Specification No:9.12 , Civil Works Including Site Preparation, Fire Rated False Partition, Civil Partition, Floor Tile, False Ceiling, False Flooring, Floor Strengthening, Doors And Painting Works, Plumbing, Etc Complete As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:6, 9, 11 , Electrical Cabling, Panels, Db, Earthing, & Necessary Illumination Devices And Fixtures As Per Technical Specification No:11 , Ip Based Cctv Surveillance System As Per Technical Specification No:11.16 , Fire Alarm System As Per Technical Specification No:11.12 , Fire Suppression System - Gas Based For Sever, Electrical, Ups & Battery Room As Per Technical Specification No:11.10 , Fire Suppression System- Sprinkler Based For All The Other Area As Per Technical Specification No:11.10 , Aspirating Smoke Detection System As Per Technical Specification No:11.13 , Public Address System As Per The Technical Specification No: 11.17 , Water Leak Detection System As Per Technical Specification No:11.9 , Rodent Repellent System As Per Technical Specification No:11.15 , Access Control System - Biometric And Card Reader With Required Number Of Access Cards As Per Technical Specification No:11.14 , Comfort Ac For All The Other Rooms As Per Technical Specification No:11.11 , Precision Ac For Server Roomas Per Technical Specification No:11.11 , Integrated Building Management System Software , Ups Of Adequate Capacity, Minimum 80Kva With 30 Min Power Backup For It Componentsas Per Technical Specification No:9.16 , Ups Of Adequate Capacity, Minimum 30Kva With 30 Min Power Backup For Non-It Components As Per Technical Specification No:9.16 , Diesel Genset Of Adequate Capacity, Minimum 125 Kva, With Amf Panels, Shelter And Exhaust Setup As Per Technical Specifications No. 11.18 , Networking Cost ( Passive Components Including Cat6 Cables, Ofc, Cat6 & Fiber Patch Cords, Liu, Rj45 Jack Panels Etc. ) , Furniture , Command Centre Workstation Desks As Per Technical Specification No:11.2 , Office / Modelling Desks As Per Technical Specification No:11.2 , Conference Table ( 10 -Seater Arrangement ) As Per Technical Specification No:11.2 , Ergonomic Chairs As Per Technical Specification No:11.2 , Installation, Testing & Commissioning , Any Other Items Not Specified Above, But Required For The Completeness Of The Objective Of The Ndrc. ( Specify ) , Flood Monitoring Centres ( Fmc ) ( 4 Nos ) In Tiruvallur, Kancheepuram, Chengalpattu, Ranipet ( It & Non It ) , Router As Per Technical Specification No:9.1 , Video Wall Solution - 70 In A 2 X 2 Arrangement With Videowall Management Solution As Per Technical Specification No:9.17 , Computers , Desktop- Control Roomas Per Technical Specification No:9.9.2 , Desktop- Admin Computers As Per Technical Specification No:9.9.3 , Phones , Ip Phone As Per Technical Specification No: 9.11 , Sat Phone As Per Technical Specification No:9.12 , Printers , Network Colour Laser Printers ( A3 Size ) As Per Technical Specification No:9.10.1 , Network Multifunction Printer ( A4 Size ) As Per Technical Specification No:9.10.2 , Passive Cabling Including Cat6 Cables, Patch Panels, Patch Cords Etc. As Per Technical Specification No:11.8 , Ups With Adequate Capacity, Minimum 15 Kva With 30 Minutes Battery Backup And Isolation Transformer As Per Technical Specification No:9.16 , Civil Works Including Site Preparation, Fire Rated False Partition, Civil Partition, Floor Tile, False Ceiling, False Flooring, Floor Strengthening, Doors And Painting Works, Plumbing, Etc Complete As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:6, 9, 11 , Electrical Panel, Db, Cable Trays, Earthing, Light Fixtures, Cabling Including Industrial Sockets And Related Accessories For Racks And Workstation As Per Technical Specification No:11 , Comfort Ac For Control Room As Per Technical Specification No:11.11 , Diesel Genset Of Adequate Capacity, Minimum 50 Kva, Including Required Foundation And Exhaust System , Ip Based Cctv Surveillance System As Per Technical Specification No:11.16 , Fire Alarm System As Per Technical Specification No:11.12 , Portable Fire Suppression System As Per Technical Specification No:11.10 , Access Control System – Card Based As Per Technical Specification No:11.14 , Furniture , Command Centre Workstation Desks ( 3 Seater ) As Per Technical Specification No:11.2 , Office Desks As Per Technical Specification No:11.2 , Conference Table ( 10 -Seater Arrangement ) As Per Technical Specification No:11.2 , Ergonomic Chairs – Work As Per Technical Specification No:11.2 , Ergonomic Chairs – Waiting As Per Technical Specification No:11.2 , Installation, Testing & Commissioning , Internet Leased Line Connectivity For Flood Monitoring Centres ( Fmc ) With 100 Mbps 1:1 Bandwidth ( 1+1 ) – Installation , Any Other Items Not Specified Above, But Required For The Completeness Of The Objective Of The Fmc. ( Specify ) , Other Cost , Training / Capacity Building To Nodal Department’S Officers In Day To Day Operation Of The Hydro Modelling Control Room, Nearline Disaster Recovery Centre And Flood Monitoring Centres For Flood Forecasting And Disaster Management Tasks. , Environmental Management Measures As Required