Centralized Cooling And De-Humidification System With Accessories On Turnkey Basis Centralized Cooling And De-Humidification System With Accessories On Turnkey Basis , Supply, Installation, Testing And Commissioning Of Following Capacity Microprocessor-Based Ductable Inverter Ac Units With Scroll Type Compressor Along With Fast Charge Of Refrigerant Complete With All Components, Controls, Inter-Locking , Electrical Accessories I / C Air Cooled Condenser As Required. Back-Up Options Must Be Available When The Main Console Fails. Temperature To Maintain Between 20 - 28 Degrees With Humidity Up To 70% , A ) 11Tr Ductable Ac Unit With Scroll Compressor With Copper Coil Similar Preferred Make, Blue Star, Carrier, Lg Or Diakin , Supplying And Installing Hard Drawn Copper Tube Duly Insulated I / C Cutting , Bending , Jointing, Brazing Etc. Complete With 9 Mm Thick Insulation As Required Of The Following Sizes. , ( I ) Suction Copper Pipe 7 / 8 , ( Ii ) Discharge Cupper Pipe 1 / 2 , Ducting Providing & Fixing G.I. Sheet Ducting I / C Plenum With Double Canvass Connections Along With G.I. Sheets Volume Control Dampers, Guide Vanes, Minor Civil Work Etc. Complete As Per Specification. Preferred Make Either Jindal Or Tata , A ) 24 Gauge , B ) 22 Gauge , Pdg. Supply Air Ductinsulation With25 Mm Thick Resin Bonded Glass Wool Insulation Density 24 Kg / Cubic Meter. Including Provision Of Vapor Barrier Covered With At Least 24 Gauge Aluminum Sheet. Preferred Make Aerocell Grade- O , Supply & Fixing 1.1 Kv Grade Xlpe Insulated Pvc Sheathed Copper Conductor Armored Cables Of Following Sizes On The Existing Tray / Surface With Saddles / Pvc Ties, End Terminations Glands, Lugs As Reqd. Frlsh Cable, Preferred Make: Polycab / Universal / Finolix / Havells , A ) 4 X 10 Sq.Mm , B ) 6 X 1.5 Sq.Mm , C ) 2 X 1.5 Sq. Mm , Plumbing For Ac Providing Plumbing Work For Drainage Requirements I / C Supply Of Cpvc Pipe, Fittings Such As Bends, Reducer, Elbows, Tees, Unions, Flanges, Including Insulation Of Piping With 6 Mm Thick Nitril Insulation Sleeve Etc. As Required. Preferred Make – Astral, Supreme Or Oriplast , A ) 32 Mm , Cable Tray Providing And Fixing Following Size Of Perforated M.S. Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Cross Members, Other Accessories Duly Suspended From The Ceiling With M.S. Suspenders Including Painting Etc. As Required:- Preferred Make: Stelco, Stillways Or Equivalent , ( A ) 150Mm Width X 50Mm Depth X 1.6Mm Thickness. , Providing And Fixing 8 Swg Gi Earth Wire On Surface / Cable Tray For Loop Earthing Along With Existing Surface Conduit / Cable As Required. Preferred Make As Approved , Providing & Fixing Extruded Aluminium Powder Coated / Anodized With Double Deflection Supply Air Grill With Adjustable Louver, Volume Control Dampers In The Air Duct As Per Specifications And Free Area Not Less Than 60% Of Grill Area As Required. Preferred Make Get Or Aarkays Or Apex Or Equivalent , Heating Kit Comprising Strip Heaters, Thermostat, Humidistat, Safety Thermostat. The Minimum Capacity Of Heaters Shall Be As Indicated Below. The Heaters Should Be Arranged In Independently Operating Banks, In The Main Return Air At Suitable Location And The Controls Shall Be Housed In A Separate Factory Fabricated Box And Complete As Required. Heater Capacity Should Cater For All Seasonal Variations And Changes In Equipment / Product Load From 0% To 100%. Heaterbankshallbeoperatedthrough Humidistat And Thermostat. Heaters Shall Be Connected In Equal Capacity Across Each Phase As Per Following. Preferred Make Gec Or Equivalent. , A ) 6 Kw Strip Heater For De Humidification , Supplying, Installation, Testing & Commissioning Of Cubical Type Lt Panel, Sheet Metal Of 16Swg Crca, 3 Phase & Neutral Mv Switch Board Suitable For Operation On 415V, 50Hz, Ac Supply Complete With Sign Writing Etc. And Incorporating The Following As Per Detailed Specifications. Make L&T, Siemens Or Schneider , I ) Busbar:- 300A Rating Three Phase & Neutral Al. Busbar ( Air Insulated ) Of Suitable Cross Section With Danger Notice Plate On Top Of Chamber. ( Approved Make ) , Ii ) In Coming:- A ) 4 Pole, 250A Mccb , 35 Ka Rupturing Capacity. Make: L&T, Siemens Or Shneider , Iii ) Outgoing:- Prefferfed Make: L&T, Siemens Or Shneider , A ) 4 Pole, 63 Amp Mccb. .. , B ) 4 Pole, 32 Amp. Mccb .. , C ) Led Type Indication Light With Single Pole Mcb 230 Volt. L&T Esbee , D ) Power Contactor 12 Amps With On / Off Selector Switch As Required , E ) Cable Alleys For All Incoming & Outgoing Ckt. Cable I / C Proper Supports / Clamping Arrangement. , F ) Digital Voltmeter & Ammeter ( 0-100A ) With Phase Selector Switch And Ct’S Of Required Ratio With All Inter-Connection, As Required. , Supply Of 80Mm. Puff Panel, Both Side 0.5Mm Thick Ppgi Sheet And Other Side Ss 304 Sheet Puff Density 40± 2 Kg / M3 Supply Of 80Mm Thick Puff Slab Puff Density 40± 2 Kg / M3. Room Size As Per The Drawing Attached Near To The Proposed Lift Area ( 2 Nos ) . , Emerson Make Condensing Unit:- Khm 530 Pqb ( On R-407C ) Or Equivalent , Evaporator Unit Luve Make / Patton :- , Copper Piping + Insulation + Accessories As Per Site Requirement :- , Temperature Controller ( Dixell Or Similar Make ) Model No. Xr02cx Or As Appropriate And Equivalent , Expansion Valve :- , Electrical Control Panel As Per Appropriate For Both Machine :- , Charging Of Refrigerant R-407C / R-404 , Drain Pipe + Other Accessories:- , Wiring + Pipe + Accessories As Per Site Requirement , Supply Of 80 Mm Thick Swinging Type Door, Both Side 0.5 Mmthick Ss304 Sheet. Puff Density 40± 2 Kg / M3 Door Size ( 900 Mm X1980 Mm ) Clear Opening With Biometric Entrance. Preferred Make As Per Puff Panel , Supply, Installation And Commissioning Of Air Curtains In Top Of Entrance Door Of Corrider Partition 4 Feet Width. Powder Coated Aluminum Adjustable Lamellas, Airfoil Shaped, So That Air Discharge Direction Can Be Adjusted To 0 – 15 Degrees Either Side Low Noise Centrifugal Double-Inlet Fans With External Rotor Motors Suitable To, Operated Of 220 Volts, Single Phase, 50 Hz, Ac Supply, The Air Curtain Shall Be Suitable For 2.5Mtr To 3.5Mtr Height I / C Suitable For Mounting Arrangement, Appropriate Electric Wiring. Preferred Make- Ocean Or Crompton Or Equivalent , Supplying & Fabrication Of M.S Structure Form Made Out Of I Section, Angle Iron, M S Flat, M S Plate, Beam For Making Of Structure I / C Cutting, Welding & One Coat Of Red Oxide And Painting With Two Coat Enameled Paint & Fixing The Same On Existing C.C Foundation Etc.Complete As Reqd. Preferred Make, Tata Or Sail Or Jindal , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level. 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . , Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. Preferred Make, Tata Or Sail Or Jindal , Lighting: Appropriate Lighting In All The Partitioned Areas With Warm White 3000 To 4000K As Required, Warm Yellow And Safe Green Light Of 535Nm Leds Must Be Fixed With Independent Control Switch And Timer Control Operation. Electrical Wiring 12 Mts For Each Light Points. About 100 Lights ( Out Of 300 ) Must Be Under Integrated Solar Panel Control And Should Be Powered By Solar Input In The Night. Safety Mcbs May Also Be Included As Per Requirement , Hanging Halogen Lamps Optimized For Crop Growth Optimized Fluence Of About 1000Micrmoles On The Gi Tables Supplied For Plant Growth ( In The Point Number 20 ) Also Needed To Be Installed On The Top Part Of The Partition In The Hall Area. , Cctv Control With At- Least 24 Ports Cameras With 2Tb Hard Discm Biometric Entrance With Cards And With Thumb Impression With A Large Monitor 65 Inch And A Datas Storage Computer, Hdmi Wire And Mouse. , Appropriate Comfortable Sitting And Analysis Table 2Feet ( W ) X 3 Feet ( L ) X 3 Feet ( H ) Chairs Are Required On The Top Partition For 06 People. , Gi Perforated, Wheel Fixed Tables, For Crop Pots To Keep, 12 Numbers, Size Per Table : 4 Feet ( W ) X 10 Feet ( L ) X 3 Feet ( H ) , Sitting Arrangements On The Top Part Of The Hall Partition For 12 People At Least. One Round Fixed Table And 12 Flexible Rolling Chairs. One Trolly With Wheel , Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cut-Outs Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Moisture Resistant Board And Thermal Insulation With Synth, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held In Position By Criss Crossing Gi Wire Etc. Along With Led Lights Should Be Fixed 6 Feet Apart. Complete As Per Directions Of Engineer-In-Charge. Gyproc / Anutone , Commissioning Of Automatic Water Sprinkler With Timer Control On The Growth Benches 40 Feet X 40 Feet With Appropriate Drainage And Water Inlet From Nearby Source. , Supplying, Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Sizedirect In Ground Including Excavationwall Or In Surface As Required. 3.5C X 150 Sq. Al Armoured Cable For Earthing. Make: Polycab / Universal / Finolex / Rr , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface / Wall Partition To Prepare The Surface Even And Smooth Complete. Prefer Make Burger, Asian Paints Or Equivalent , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work. Prefer Make Burger, Asian Paints Or Equivalent