}

Pkg 3 Rate Contract For Supply Of Different Instruments For Water Sample Test For Various Water Testing Laboratories Under Jal Jeevan Mission Assam , Autoclave Vertical • Size-35Ltr • It Should Have Double Wall Construction With Boiler Made Of Stainless , guwahati-Assam

Government Departments has published Pkg 3 Rate Contract For Supply Of Different Instruments For Water Sample Test For Various Water Testing Laboratories Under Jal Jeevan Mission Assam , Autoclave Vertical • Size-35Ltr • It Should Have Double Wall Construction With Boiler Made Of Stainless . Submission Date for this Tender is 01-08-2022. Uniform Tenders in guwahati Assam. Bidders can get complete Tender details and download the document.




Tender Notice

32946617
Corrigendum : Pkg 3 Rate Contract For Supply Of Different Instruments For Water Sample Test For Various Water Testing Laboratories Under Jal Jeevan Mission Assam , Autoclave Vertical • Size-35Ltr • It Should Have Double Wall Construction With Boiler Made Of Stainless
Open Tender
Indian
Assam
Guwahati
01-08-2022

Tender Details

Pkg 3 Rate Contract For Supply Of Different Instruments For Water Sample Test For Various Water Testing Laboratories Under Jal Jeevan Mission Assam , Autoclave Vertical • Size-35Ltr • It Should Have Double Wall Construction With Boiler Made Of Stainless Steel 16-Gauge Sheet. Outer Shell Should Also Be Made Of Stainless-Steel Sheet / Mild Steel. Boiler And Outer Shell Should Be Provided With Air Insulation. Lid Should Be Made Of Stainless-Steel Sheet And Tightened All-Round By Radial Locking. Joint Less Gaskets Should Be Made Of Neoprene Rubber. These Unit Should Be Hydraulically Tested To Withstand Up To 40 Psi. • Should Have Fully Automatic Pid Controller • Automatic Timer Electronic 999 Mts • These Units Should Be Fitted With Water Level Arrangement To Indicate Water Position Inside The Boiler. Pressure Gauge, Air / Steam Release Cock & Two Safety Valve Should Also Be Provided. The Autoclave Should Be Fitted With Indfosspizzostat And Can Be Set Between 10 To 20 Psi. • Immersion Type Heating Element Heats The Water And Steam To Desired Temp. And Pressure Are Attained. Autoclaves Should Be Able To Cut-Off Automatically When The Autoclave Is Dry. Supplied Unit Should Come With Atleast S.S. Basket, Cord And Plug To Work On 220 Volts 50 Cycles A.C. Supply • Traceability Calibration Certificate Of Controller Should Be Provided • Instrument Should Be Calibrated From Nabl Calibration Laboratory. , Sterological Water Bath *Nominal Capacity - 20 L, 8 Holes With Lid Assembly, *Working Temperature Range Ambient +5°C To 99°C, *Temperature Stability ±2.0°C, *Interior Dimensions ( 528 X 325 X 150 ) Mm , *Exterior Dimensions ( W X D X H ) ( 530 X 326 X 2600 ) Mm, *Display 7 Segment Led Display *Tank Material Ss 304 , *Outer Body Ss 304, *Electrical Requirements 9 A, Power Consumption 1600 W, Calibration From Nabl Lab , Ion Meter With Electrode And Accessories For Fluoride Meter: Ph / Ise Benchtop Meter With Electrode Stable, Universal Power Adapter, Literature, Pc Cable, Meter Test Certificate Electrode: Ionplus Fluoride And Nitrate Combination Ion Selective Electrode, 1M Cable, Waterproof Bnc Benchtop Ion Meter ( Ise ) Along With Fluoride, Nitrate#Electrode • Range: -2.000 To 20.000 • Resolution 0.1, 0.01, 0.001 • Relative Accuracy ±0.002 Calibration Points Up To 5 • Calibration Editing Yes#Mv / Rmv • Orp Range ±2500.0 • Mv Resolution 0.1 • Relative Accuracy ±0.2 Mv Or ±0.05 % Of Reading Whichever Is Greater • Eh Orp Mode Yes Ise • Range 0 To 19999 • Resolution Up To 3 Significant Digits • Relative Accuracy ±0.2 Mv Or ±0.05 % Of Reading Whichever Is Greater • Units Ppm, M, Mg / L, %, Ppb, None • Calibration Points Up To 5 • Calibration Editing Yes • Calibration Features Timed End Point, Linear Point To Point, Non-Linear Selectable Auto-Blank, Low Concentration Range Stability #Temperature • Range -5 To 105 °C, 23 To 221 ºf • Resolution 0.1 • Relative Accuracy ±0.1 • Offset Calibration 1-Point Datalogging • Memory 2000 With Time And Date Stamp • Log Function Manual, Ready ( Include Auto-Read™ ) , Timed • Log Edit Delete Individual Points, Group Of Points Or All Inputs • Ph Electrode Bnc, Reference Pin • Atc Probe 8-Pin Mini-Din #Output • Rs232, Usb Power • Ac Adapter Included – Universal, 100-240 Vac • Battery Power Optional – 4 Aas • Battery Life 800 Hrs , Inverter ? Capacity - 3 Kva ? 5 Star Rating ? 6 Hrs Backup ? With Battery , Bacteriological Incubator Inner Size: 18 X 18 X 24, Rating Watts 750, No. Of Shelves 3, Capacity 120Ltrs Construction: Double Walled Construction Outer Body Made Of Mild Steel Powder Coated, & Inner Body Made Of Stainless-Steel Insulation: Glass Wool Insulation Between Two Walls. Temp Range: Room Temperature To 60°C. Accuracy: + / - 0.5 °C. Temp Controlled By: Controlled By Pid Micro Process Controller With Dual Display. Selves: With G.I. Wire Mesh Selves Door: 2 Door Inner Acrylic Door To View Sample & Outer Metal Door. With Air Circulation Motor With Blower For Uniform Temperature Throughout Chamber. Heater: Special Nichrome Heater Designed For Long Life & Saving Of Power Consumption , Bod Incubator ? The Unit Should Be Double Walled With Outer Body To Be Made Of Ms Sheet Treated For Degreasing & Rust Proofing Duly Powder Coated And Inner Chamber To Be Made Of Stainless Steel ( 304 Grade ) Sheet ? To Be Provided With Adjustable Stainless Steel Wire Mesh / Perforated Shelves ? Space Between Inner Chamber And Outer Wall Should Be Filled With High Grade Mineral Wool For Minimal Heat Loss ? The Double Walled Door To Be Fitted With Glass Window To Facilitate Viewing Inside Chamber Without Disturbing The Inner Temperature And Should Be Of Synthetic Rubber / Fibre Gasket. Unit Should Have Ventilation Slides On Two Sides To Control Inner Air / Vapour Circulation ? To Be Fitted With Beaded Heating Elements Placed In Ribs, At Bottom And Sides For Uniform Heat Distribution. Unit Has To Be Fitted With Two Lamps And On / Off Switch ? To Work On 220 / 230Volts Ac Supply. Technical Specifications: ? Temperature Control - By Digital Temperature Indicator-Cum-Controller ( With Display For Set Value And Present Value ) From +5° C Ambient To 70°C, ± 0.5°C At 50°C. To Be Fitted With Air Circulating Fan To Maintain Uniform Temperature Throughout The Working Chamber. ? Working Chamber Size: 459X450x600 Mm ( 2 Trays ) -Approximately 120 Lit , Cod Meter ? Reagent Free Measurement Of Cod ? Measuring Method : Spectral Measurement In The Uv-Vis Range ( 200 – 720 Nm ) ?Dectection Range: 0 - 800 Mg / L ? Resolution 0.1 Mg / L ? Should Be Made Of Waterproof Hand-Held Meters For The Determination Of Cod On Site ? The Meter Should Be Rugged, Water Resistant & Designed To Be Used For Field With All Accesories. , Cod Thermo Reactor / Cod System Reflux Type Sealing Positions -12 Position, Capacity 16 Mm X 100 Mm Vials, Heating Block Aluminium, Temperature Range Ambient To 180°C Temperature Accuracy ±1°C, Display Led Process Timer 0-999 Min / Infinite Temperature Control Yes With Set Value And Present Value Time Control Yes With Set Value And Present Value Transparent Lid Uv Protection Power Consumptions 200 W Current Consumption 1.5 A Unit External Dimensions ( Wxdxh ) ( 275 X 185 X 150 ) Mm. Along With 12 Nos, Tubes. , Do Meter With Optical Probe Display: 3.5 Color Display Do Barometer Accuracy: ±3 Mbar Do Barometer Range: 300 - 1, 100 Mbar Do Barometer Resolution: 1 Mbar Do Calibration Points: 2 Do Measuring Accuracy Mg / L: 0.00 - 8.00 Mg / L: ±0.1 Mg / L 8.00 - 20.00 Mg / L: ±0.15 Mg / L 20.00 - 50.00 Mg / L: ±10% Do Measuring Range % Saturation: 0.0 - 500% Do Measuring Range Mg / L: 0.00 - 50.00 Do Measuring Resolution % Saturation: 0.1% Do Measuring Resolution Mg / L: 0.01 Do Response Time: T99: <20 S Do Salinity Compensation: Manual Do Salinity Compensation Range 0.0 - 70.0 Psu Do Selectable Measuring Units: % Air Sat; Mg / L; Ppm; ?Mol / L; Mbar; Torr; Dphi Do Temperature Range: 0.0 - 60 °C Do Temperature Resolution: 0.1 °C Good Laboratory Practice ( Glp ) : Yes, Data With User Id, Timestamp, Electrode Id Measuring Inputs: 2 Measuring Mode: 1 X Ph / U / T Analog 1 X Ph / U / T / Do Digital Memory Size: 10, 000 Measured Values Mv Accuracy: ±0.2 Mv Mv Range: -1, 200.0 Mv - +1, 200.0 Mv Mv Resolution: 0.1 Mv Ph Accuracy: ±0.003 Ph Ph Calibration Points: 1 - 5 Ph Range: -13.000 - +20.000 Ph Resolution: 0.001 Ph Power Supply: Lithium-Polymer Rechargeable Battery 3.7 V; 3, 000 Mah Protection Class: Ip 67 , Manifold Filtration Assembly * Wide Range Of Pumps And Filtration Flasks * High Quality Components * Easily Exchangeable Elements *Maintenance-Free * Low Noise * Added Filters For Enhanced Pump Longevity * Filtration Base With Silicon Stopper, Cap & Aluminium Clamp ? Connecting Silicon Tube ?Technical Specification For Filtration Flask Set # High-Pressure Resistant Tube # Fiberglass Filter Membranes ( 47Mm / 0.1 ?M ) # Ptfe Disc Filter #Normal Liquid Filtration * Specification For Filtration Glass Set #Suction Bottle Capacity ( Ml ) 1000 Ml # Filter Diameter ( Mm ) 47 / 50 Mm # * Specification For Filter Flask * Material: Statinless Steel 304, Capacity: 300 Ml ( 100 Ml Each ) [ Unit Should Consist Of 3 Flask So That 3 Sample Can Be Filtered Simultanelously Without Any Issue ] # Effective Filtration Area ( Cm2 ) = 9.6 Cm2, Outlet Connector ( Mm ) = 8 Mm * Specification For Vaccum Flask: #Flow Rate Of The Pump ( L / Min ) = 17 L / Min Ultimate Vacuum ( Mbar ) = 150 Mbar # Oil Free, Maintainance Free, Built In Thermal Protection To Shut Off When Over Heated. , Laminar Air Flow ( Horizontal ) • Working Table Of Ss-304 • Hepa Of 0.3 M Of An Efficiency Of 99.7 % • Confirm International Standard 209 E • Statically Balanced Motor • Velocity At The Output Of Hepa 90+ 20 Fpm• Vibration Is Also Very Low • Work Area Is Properly Illuminated By Diffused Glare Free Fluorescent Light • Front & Side Door Of Acrylic Sheet ( Transparent ) • Cock For Gases Or Vacuum Line • Lcd Display With Soft Touch Switches For Motor, Uv Light, Uv Timer • Microprocessor Based Touch Screen Display • Door Sensor To Switch Off Uv Light When Door Is Closed • Control Of Uv Light To Prevent Operator From The Uv Rays As And When Required. , Microscope ? Binocular ? With Lcd Display ? Connectivity With And Without Cpu , Dessicator ? Normal Desiccators ? Size 160 Mm? For Use With Disposable Or Reusable Desiccant ? Complies With Is 6128 : Specification For Desiccators , Hygrometer Temp Range -500C ~ +700C Temp. Measuring Accuracy: ± 10C Temp. Resolution: 0.10C Humidity Measuring Range: 10% Rh ~ 99% Humidity Accuracy: ±5% Rh Humidity Resolution: 1% , Hot Plate ? Body To Be Fabricated Out Of Thick Mild Steel Sheet, Duly Finished In Epoxy Powder Coated ? The Hot Plate Top To Be Made Of Stainless Steel Thick Sheet & Smoothed Duly Finished Should Be Firmly Mounted On The Body ?Heavy Duty Heating Elements Should Be Securely Laid Under The Plate To Operate On 220 / 23Ov Ac Supply ? Temperature In Controlled By Energy Regulators Fitted With An Indicator Lamp For The Mains ? To Be Supplied With Main Cord And Plug. Technical Specifications: ? Top Plate Size: 30 X 45 Cm ?Load: 2 Kw , Ph Meter ? Conforms To National Accreditation Board For Testing And Calibration Laboratories ( Nabl ) & National Institute Of Standards &Technology ( Nist ) Guidelines ? Automatic Electrode Recognisation? Built In Glp Function ? Graphic Lcd Display Of Ph, Orp Readings, Temperature, Electrode Status, Calibration Points, Date And Time ? Hard & Water Proof Casing ? Help Menu ? Ph Range: 0-14 Ph ? Resolution: 0.01 Ph? Accuracy: ±0.01 Ph ? Calibration Point: Up To 5 ? Auto-Buffer Recognision? Auto Temperature Compensation ? Windows Compatible Software ? Usb Cable For Pc Connection ? Detachable Electrode Holder ? The Unit Should Be Supplied With ( I ) Ph Meter With Refillable Ph Electrode ( Ii ) Temperature Probe And Ph Electrode ( Iii ) Electrode Stand With Swivel Arm ( V ) Rs232 Cable ( Vi ) Operating Manual , Ph Meter ( Portable ) # Ph Range - 0 To 14.00 Ph; #Batteries: 4 X 1.5 V Alkali-Manganese Batteries, Type Aa; #Operational Life: Up To 800 H Without / 100 H With Illumination. #Resolution / Accuracy 0.001 Ph / ± 0.005 Ph; # Operation Temp - 0°C-100°C # Orp Range ± 2500 Mv; # Usb Interface- Usb B ( Device ) , Data Output; # Admissible Relative Humidity- Yearly Mean: < 75 %, 30 Days / Year: 95 %, Other Days: 85 %# Resolution 0.1 ( ± 1200.0Mv ) / 1 Mv ( Beyond ) ; #Emc- Ec Directive 2004 / 108 / Ec # En 61326-1; # 1.2 ± 0.2 ( ± 199.9 Mv ) / ± 2 Mv ( Beyond ) # Temp Range 0.0 To 100.00 C ( 32.0 To 212.00 F ) # Resolution / Accuracy 0.1 0C ( 0.1 0 F ) / ±0.3 ºc / ±0.5 ºf ( 0 To 70 ºc ) # Atc Yes ( 0 To 100 0 ºc ) Buffer Options Usa: Ph 1.68, 4.01, 7.00, 10.01, 12.45 # Nist Ph 1.68, 4.01, 6.86, 9.18 , 12.45 # No. Of Ph Calibration Points 5Points # Built-In Electrode Arm Yes # Memory 100 Data Sets # Electrode Included Ecfc7252101b, Single Junction Ph Electrode. # Temp Probe Included # Lcd Display Custom Dual-Display Lcd # Power Requirements Included, 100 / 240Vac Smps Power Adapter # With Us / Uk / Eur / Japan Plug , 9V, 6W, Centre , Turbidity Meter #Range: 0-4000 Ntu; # Certification: Ce, Fcc, Ec, En, Ul Std #Communication: Rs 232, Usb Via Adapter #Compliance: Iso #Data Log: 1000 Total Logs, Includes Reading Log, Verification Log And Calibration Log, Date Time, #User Display: Lcd Graphic, Backlit, Menu Controlled #Interface: Rs 232, Usb Via Adapter, External Printer, Barcode Scanner, Pc #Light Source: Light-Emitting Diode ( Ir Led ) / Tungsten Filament Lamp #Measurement Method: Nephelometric #Operating Temperature Range: 0 - 50 °C #Power Requirements ( Voltage ) : 100 - 240 Vac With Lab Station, Battery Operated 4 X 1.5 V, Type Aa For Approx. 3, 000 Measurements #Resolution: 0.001 Ntu; #Repeatability ±1% Of Reading Or 0.01 Ntu Whichever Is Greater # Accuracy: ± 2% Of Reading Plus 0.01 Ntu From 0 - 1000 Ntu, ±5% Of Reading From 1000 - 4000 Ntu Or Better #Reading Modes: Single, Intelligent Reproducibility And Plausibility Check ( Irpc ) Procedure #Regulatory: Meets Iso 7027, Din En 27027 #Response Time: <15 Seconds , 20 Ml Sample Volume #Calibration Point Automatic 3-Point Calibration #Source Lamp: Led #Stabilization Time: Immediately #Storage Conditions: -20 To 65 °C #Units: Fnu And Ntu #Relative Humidity Yearly Mean: < 75 %; 30 Days / Year: 95 %; Other Days: 85 % #Type Of Protection: Ip 67 , Conductivity Meter / Tds Meter # Conductivity 0.00- 1000 Ms / Cm; # Batteries: 4 X 1.5 V Alkali-Manganese Batteries, Type Aa # Resolution 0.001 ?S / 0.01 ?S / 0.1 ?S; 1 / 0.01Ms / 0.1 Ms; Operational Life: Up To 800 H Without / 100 H With Illumination # Accuracy ±0.5 % Of Value ( Salinity ) ; # Usb Interface - Usb B ( Device ) , Data Output # Resistivity 0.00-199.9 M?Cm; # Emc - Ec Directive 2004 / 108 / Ec En 61326-1 # Resolution 0.001 / 0.01 / 0.1 O; 0.001 / 0.1 K?; 0.01 M? # Accuracy ±0.5 % Of Value ( Resistivity ) # 0.0 -70.0 According To The Iot Table # Resolution 0.1; Weight 0.8 Kg; Ip Class: Ip 43 # Accuracy ± 0.1; # Operational Temp: +5 °C ... +55 °C; # Admissible Relative Humidity: Yearly Mean: < 75 % 30 Days / Year: 95 %, Other Days: 85 % # Tds Range 1 … 1999 Mg / L, 0 … 199.9 G / L ( @ Tds Factor 1.00 ) # Resolution 1 Ppm; 0.01 / 0.1 Ppt; # Accuracy ±0.5 % Of Value # Temp Range -5.0 ... +105.0°C # Resolution 0.1°C; # Accuracy ± 0.1°C None, Nlf, 0.000 … 10.000 % / K # Reference Temperature 20 °C / 25 °C # Built-In Electrode Arm Yes # Compensation Atc / Mtc # Memory 5000 Data Sets # Electrode Included, 4 Cell Graphite Electrode, # Conductivity Electrode, K=0.475 # Power Requirements Input: 100 / 240 V ~ / 50-60 Hz / 270 Ma # Output: 9 V = / 1.1 A , Tds Meter ( Portable ) ?Multi-Point Push-Button Calibration ( Up To 5 Points ) With ± 1 % Full Scale Accuracy ? Automatic Or Manual Calibration- For Quick, Easy Calibration; Use Automatic Mode ? With Pre-Set Calibration Points At Most Popular Values Or Manually Set Values In The Manual Mode For More Flexibility ? Auto-Ranging For Conductivity / Tds Measurements For Fast Response And Best Resolution Over Wide Measurementrange? Adjustable Tds Factor For More Accurate Measurement ? Automatic Temperature Compensation ( Atc ) For The Optimum Accuracy Under Fluctuating Temperatures ? Hold Function Momentarily Freezes Reading For Easy Viewing ? Auto-Power Off Saves Battery Power After Non-Use ? Self-Diagnostic With Message Codes For Easy Troubleshooting ? Large Custom Lcd Provides Optimum Viewing Even At Adistance? Electrode With Built-In Atc Designed Forminimal Air Bubble Entrapment During Measurement ? Protective Rubber Boot Shields Meter From Drops Andfeatures A Sturdy Built-In Stand For Easy Bench-Topoperation. Technical Specifications: ?Tds Range-0.00 - 9.99 Ppm / 10.0 - 99.9 Ppm / 100 - 999 Ppm / 1.00 - 9.99 Ppt / 10.0 - 99.9 Ppt? Resolution-0.05 % Full Scale Accuracy- ±1 % Of Full Scale ± 1 Lsd ?Tds Factor-0.30 To 1.00 ?Temperature Range- 0.0 To 80.0 °C ?Resolution- 0.1 °C ?Accuracy- ±0.5 °C ?Compensation Automatic / Manual ( 0 To 80 °C ) ? Normalization 20.0 Or 25.0 °C Operating Temperature- 5To 45 °C ? Calibration Points- 4 ( 1 Per Range ) Auto, 5 ( 1 Per Range ) Manual Temperature Coefficient- 0.0 - 10.0 % ?Cellconstant- 0.1, 1.0, 10.0 Auto Off- 20 Min After Last Keypressed ? Input- Bnc, 2.5 Mm Phono Socket Power- 4 X 1.5 V Aaa Alkaline Batteries To Be Included The Meter Should Be Supplied With ( I ) Basic Meter With Conductivity Electrode With Cell Constant 1.0, ( Ii ) Tds Calibration Solution 500 Ml ( 50 Ppm, 300 Ppm, 3000 Ppm ) ( Iii ) Di Rinse Water ( 60 Ml Each ) , ( Iv ) Grip-Clip, ( V ) Batteries In Hard Carrying Case, ( Vi ) Operating Manual. , Auto Cut Heater For Distill Water Plant So That When Water Level Decreases The Heater Is Switch Off Automatically , Digital Balance ? Should Have A Chemical Resistant Full Metal Body ? Automatic Internal Adjustment ? Built In Overload Protection ? Glove Friendly Large Tft Lcd Color Capacitive Touchscreen Display ? Technical Specification: Max Capacity 220 G ? Readability: 0.1 Mg ? Settling Time 2 S * Unit Should Be Calibrated By Nabl Calibration Laboratory. , Voltage Stabilizer ? Capacity- 3 Kva ? Servo Stabilizer ? 5 Star Rating , Heating Mentle ( Single Station ) ?Should Have Digital Energy Regulator With Multiple Step Power Regulation ? Automatic Spill Detection And Saftey Shutdown ? In Built Precision Temperature Control ?Technial Specification: Flask Capacity 250 Ml, Working Temp Range: Ambiant + 5 To 420 Degree Celcius. Accuracy: Plus Minus 1.0 Degree Celcius, Power Consumption : 150 W , Heating Mentle ( Combined Unit ) • Material Of Construction – Heating Block: Made With Grade Epoxy Painted Chemical Resistant Coating, Aluminum Block With 6 Thermo Wells For Processing 6 Different Samples At A Time. #Racks: Ss 316 # Glassware: Teflon Coated # • Temperature Range – Ambient + 10 Deg C To 450 Deg C # • Stability Of Temperature – Better Than ± 0.5 Deg C #• Controller – Consist Of Digital Read Out Of Temperature And Time With 4 Programmable Ramps For Each Method. # • Number Of Programmable Methods – 20 Numbers. # • Heating Powers – 1000W # • Heating Position – Minimum 6 Position # • Digestion Time Range -1 To 999 Minutes # • The System Should Have Facility Of Acoustic Signal At The End Of Completion Of Cycle To Notify The Operator. # • The Thermal Digestion Unit Should Have High Thermal Homogeneity # • The Setup Should Have Small Footprint. # • The Offer Systems Should Be Suitable To Din 38414-S7 Standard # • The Unit Should Work On 230 V / 50 Hz Ac , Water Bath ? The Unit Should Be Of Double Walled Construction, Argon Welded, And Inner & Outer Wall Made Of Ms Sheet ? Ss Lids Having 75Mm Dia. Holes With Removable Concentricrings? The Gap Between Outer And Inner Walls Should Befilled With Special Grade Glass Wool Insulation ? Temperature Control From +5°C Above Ambient To 99°C ? The Unit Would Be Fitted With Capillary Type Thermostat With Arbitrary Scale Dial For Temperature Control From +5° Cabove Ambient To 99°C ± 1°C ( At 50°C ) . , Hot Air Oven # Size: -18X18 X18 / 18X24x18 # Double Walled Inside Aluminium / Stainless Steel 304 Qty. • Outside Made Of Mild Steel And Painted In Epoxy Powder Coating. • Insulation Of 75Rnm By Mineral Wool. • Double Walled Inside Aluminium / Stainless Steel # Good Stoving Enamel With Adjustable Wire Mesh Nichol Plated Trays # Heating Elements Are On Three Sides Bottom Lhs & Rhs. Ribs. # With Air Ventilators On Two Sides. # Microprocessed Electronic Digital Controller Cum Indicator From Few C Above Ambient To 300 C ±0.5C Having Two Windows Display Sv & Pv, Auto Tuning, Timer Up 999 Mts ( Selectable ) , Low & High Temp. Accuracy Alarm, Cycle, Timer With Buzzer. # Outside Made Of Mild Steel And Painted In Epoxy Powder Coating. # Insulation Of 75Rnm By Mineral Wool. # Double Walled Inside Aluminum / Stainless Steel # Heating Elements Are On Three Sides Bottom Lhs & Rhs. Ribs. # With Air Ventilators On Two Sides. # Steel Stand Should Be Provided Along With Tyres On Which Instrument Has To Be Kept. # Traceability Calibration Certificate Of Controller Should Be Provided # Instrument Should Be Calibrated From Nabl Calibration Laboratory. , Magnetic Stirrer With Hotplate ( 5 Station ) # The System Will Be Aluminium Moulded Construction With Highly Scratch And Chemical Resistant Ceramic Top. The System Will Have Digital Set Up Temperature Controller With Led Display. There Will Be Even Heat Distribution On Surface Of Top And May Assist Beaker Up To 5000 Ml. # It Will Have High Magnetic Strength With Single Multi-Turn Intelligent Knob Operation And User Settable High Temperature Cut Off And Hard Wired Cut Off. It Will Have High Temperature Up To 550°C. # T Will Have High Magnetic Strength With Single Multi-Turn Intelligent Knob Operation And User Settable High Temperature Cut Off And Hard Wired Cut Off. It Will Have High Temperature Up To 550°C. # It Will Be Supplied With Temperature Sensors Probe # Technical Specification: * • Heating Plate Material - Glass Ceramic Top Plate Dimension Of Heating Plate - 180 Mm X 180 Mm • Two Display Windows For - Temperature And Rpm • Speed Range - ~2000 Rpm• Heat Output - 1300 W • Temperature Range - Ambient To 550°C • Adjustable Safety Cut Off - 580°C • Control Accuracy Of Sensor - ± 1K • Permissible Ambient Temp. - 5 - 40°C • Permissible Relative Moisture - 80% • Should Come With 3 Different Sized Magnet • Dimensions Of Hot Plate Body - 378X220x103 • Ip Class - 21 , Vacuum Pump Max Pressure 80 Psi, Piston Powered, Oil Free, Maintainance Free, Built In Thermal Protection To Shut Off When Over Heated. , Colony Counter ? Hand Held ? Micro Controller Based ? 6 Digit [ 999999 ] Lcd Counter ? Built In Buzzer, Marker Pen, And Counters ? Memorizes Last Count ? As Per Gmp Specifications ? Hold And Count Correction Facility , Chambered Water Bath Routine Laboratory Analysis Which Need Stable Temperature. Fully Stainless Steel Gmp Construction. Leak Free Inner Seamless Die Pressed Chamber. Easy Chamber Cleaning And No Microbes Harboured Due To Contoured Corners All Around. Elegant Looks - External Matt And Internal Glossy - Full Ss 304 Construction. Temperature Range Ambient +5 To 99.9°C. Pid Temperature Controller. Control Accuracy At 37 Is ±0.3°C. Inner Dimension300 X 150 X 150 Mm; Approx Capacity 5 Litre , Colour Comparator For Colour #Applicable Standard Astm D1209 Iso 6271, # Colour Type Transparent, # Portability: Portable, # Range-Visual Colour Grading Of Platinum-Cobalt / Hazen / Apha Colour ( Range 0 - 250 Mg ) , # Disc-Nsb Hazen Scale Disc Range: -70 - 250 Mg Pt / L Caa Hazen Scale Disc Range: -0-30 Mg Pt / L Cab Hazen Scale Disc Range: -30-70 Mg Pt / L ( The Bidder Should Provide Colour Glass Disc ) , # Nessleriser * 1 X Pair Nessleriser Daylight 2000+ *1 X Pair Stand For Nessleriser Unit *1 X Pair 2150 Nessleriser Body *1 X Pair 2250 Nessleriser Body *1 X Pair Of Nessler Cylinder Af306p *1 X Pair Of Nessler Cylinders 250Mm Db420 # Certification * The Company Should Have Iso Certification For Manufacture Water Testing Instruments , Pipette Controller # Technical Specifications: It Will Be Battery Operated Electronic Pipette Filling Device And Will Have Ergonomic Design And Robust. The Pipette Must Extend Smooth Operation. The Device Must Have Designed To Be Used For Most Of The Plastic & Glass Pipettes Having Volume From 0.1-100 Ml. The Device Must Be Autoclavable. It Will Be Light In Weight So It Can Be Used For Continuous Operation Without Fatigue And Enable Single Handed Operation With Minimum Efforts. It Will Have Dual Dispensing With A Single Knob: The Instrument Will Have Different Modes For Dropwise& Slow Dispensing Or Fast Dispensing ) . The Device Will Have Continuous Pump Speed Adjustment During Liquid Handling Operations. It Will Have Replaceable Ptfe Hydrophobic Membrane Filter ( 0.2Microns ) To Prevents Aerosol Contamination And Accidental Liquid Entry. # Other Technical Specifications: *Fit: Pipette Made Of Glass Or Plastic *Size: Pipette Of Volume Size 0.1 Ml To 100 Ml *Battery: Li-On Or Ni-Cd Batteries Battery *Charger: Compatible With Both 220V And 110V *Battery Indication: Low Battery And Charging Indication *Operation: Minimum 6 Hr Continuous Operation *Autoclaving Parameters: Autoclavable At 121 °C And 15 Psi For A Duration Of 10-15 Minutes. *Warranty: 2 Years , Calibrated Weights Standard Weight Box Class F1 Capacity 1 Mg To 200 Gm With Nabl Accredited Lab Calibration Certificate ( Set Of 23 Wire Weights ) , Jar Testers / Floc Tester • Accepts Six Samples • Led Digital Display • Digital Indication Of Speed And Timer • Digital Timer From 0 To 99 Minutes • Two Pre-Set Programs • Built In Illumination For Easy Viewing Of Sample • Speed Range 25 To 200 Rpm • Power-230V, 50Hz, 100 W , Digital Thermometer With Probe # Mini Lcd Thermometer #Type: Digital #Sensor Cable Length: 1 Meter Waterproof Probe # Batteries: 2 X Batteries Should Be Included # Temperature Range: -50~ 110°C # Temperature Measurement Accuracy:±1°C , Vortex Mixture With Volumetric Flask Base Foam And 25, 50, 100 Ml Vol. Flask Hold_Belt # Touch, Standby & Continuous Mode # Overload & Over Current Protection # Ac Motor For Quick Acceleration & Low Maintenance # Easy Recognition Of Mixing Mode With In Build Led Lamp #Technical Specification: * Speed: 200 To 2800 Rpm * Orbital Diameter: 4Mm * Timer Setting 0 - 999 Min , Rotary Shaker #Plate Size: 12X12 Inch # Speed Range 50-400 Rpm # Digital Speed Indicator # Digital Countdown Timer: 99 Min # Shaking Orbit: 10 Mm # Flask Capacity: 5X500 Ml , Microwave Oven # 30 Litre Capacity, # Convection Type , Laboratory Centrifuge #Stainless Steel Centrifuge Chamber, Easy To Clean, #Brushless Induction Motor With Variable Frequency Drive, #Microprocessor Controller With Digital Display, #Stable Speed Output Even Under Unstable Voltage Condition, #Smooth & Soft Start, #Low Sample Temperature Rise, #Inverter Fault Detection Without Shutdown, #7 Segment Led Display Of Speed, #Digital Countdown Timer & Continuous Run, #Safety Lid Interlock To Prevent Lid Opening During Centrifugation, #Imbalance Detection & Centrifugation Stop With Display Of Error, #Dynamic Brake For Quick Deceleration, #Motor Overload Protection, #Gas Hinge To Prevent Door Falling, #Emergency Lid Lock Release, #Last Set Parameters Recall ( Useful For Repetitive Analysis ) , #Wide Variety Of Rotors & Reduction Adaptors, # Technical Specification: * Max Speed: 6000 Rpm, *Max Rcf 5070 G, * Max Capacity: 400 Ml, * Digital Timer Range: 0-59 Min, *Rotor Head Capacity: 6 X 50 Ml , Ph Electrode ( Bnc Connector Cable ) General Purpose Plastic-Body Ph Electrode. Comes With 10 Ml Refilling Electrolyte Should Be Usuble With All Ph Meters With Bnc Input Connector. , Ph Electrode ( Open Pore Cable ) General Purpose Plastic-Body Ph Electrode. Comes With 10 Ml Refilling Electrolyte Should Be Usuble With All Ph Meters With Open Pore Input Connector , Conductivity Cell ( Bnc Connector ) General Purpose Universal Conductivity Cell Which Can Be Used With All Bnc Type Connector Conductivity Meter. Cell Constant = 1 , Conductivity Cell ( Bnc Connector ) General Purpose Universal Conductivity Cell Which Can Be Used With All Bnc Type Connector Conductivity Meter. Cell Constant = 0.1 , Conductivity Cell ( Open Pore Cable ) General Purpose Universal Conductivity Cell Which Can Be Used With All Open Pore Input Connector. Cell Constant = 1 , Conductivity Cell ( Open Pore Cable ) General Purpose Universal Conductivity Cell Which Can Be Used With All Open Pore Input Connector. Cell Constant = 0.1 , Heater For Glass Distillation Unit Universal. Should Be Able To Use With All Double Distillation Water Filtration Plant. Capacity= 1Kw , Turbiditymeter Glass Tube Universal. Should Be Able To Use With Any Turbiditymeter. Capacity = 10Ml.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-07-2022 Date Corrigendum Date 01-08-2022
2 22-07-2022 Technical Corrigendum Technical Bid 01-08-2022

Key Value

Document Fees
INR 2000 /-
EMD
INR 100000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail