| 1 | Dismantling brick tiles or terracing tiles single layers on roof complete all as specified and directed |
| 2 | Demolition of mud in roofs, any thickness including plastering/pcc padding and leaping (where full thickness removed or only a part thereof) complete all as specified and directed |
| 3 | Roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc including dismantling existing membrane complete all as specified and as directed. |
| 4 | Brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified and as directed. |
| 5 | M&L for cutting out cracks to V section in existing roofs or terracing, cleaning out wetting grouting with cement and slurry 1:3, complete all as specified and directed. |
| 6 | M & L PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation filling, mass concrete, sub base or leveling course of floor, roof etc complete all as specified |
| 7 | Demolition of cement concrete in any description and in any position not otherwise specifically provided for and removing debris, etc. to Outside MD/AF Land, complete all as specified and as directed. |
| 8 | M&L for providing cement concrete type B0 (1:2:4) 12.5 mm graded stone aggregate for providing slope, roof kerbs or mud stops rounded or chamfered edges all as directed by engr-in charge |
| 9 | M&L for 10mm thick Screed bed or bedding layer in cement mortar 1:4, laid on roof, mixed with water proofing compound when concrete is green, as per manufacturere instructions complete all as specified.(Note -Water proofing compound shall be measured and paid separately). |
| 10 | Supplying only liquid water proofing compound, ISI marked complete all as specified and as directed. |
| 11 | M&L for APP based polymeric membrane of minimum 3 mm thick and minimum weight not less than 3.0 Kg/sqm, reinforced with polyster non woven fabric matt (weight not less than 150 gm/sqm), laid with forced application over roof surface with a coat of hot blown bitumen conforming to IS-3384-1965 of grade 85/25 @ 1.2 kg/Sqm at bottom of the membrane as bonding material, complete all as per manufacturer\"s instructions all as specified and directed by Engineer-in-Charge. |
| 12 | M&L for UV stable single component fibre reinforced elastomeric liquid applied waterproofing membrane having solid content of 55% formulated wih PU hybrid polymers and reinforcing acrylic fibres and having sun reflectivity Index (SRI) of 106. The application of the material should be done in three coat (6 hr gap after each coat) on the substrate, applying first self priming coat at ratio of damp proof ultra and water 3:1 then 2 undiluted coat of damp proof ultra obtaining coverage @1 ltr/10 sqft in three coats. The vital physical and chemical parameters shall be as under. Min elongationat break of 350%, crack bridging ability of 2.5 mm @650 microns thickness, resists positive hydrostatic pressure of up to 10 bars. The material shall be appliied with brush or roller, complete in all respect as per the direction of Engr-in charge/consultant. Also, proper surface preparation along with covingat corners is must. (Make: Asian paints or equivalents).Note: The work shall be executed by the authorized applicator of the manufacturer only. |
| 13 | M&L for Racking out joints/pointing to brick tiles and flush pointing with 1:3 cement mortar with water proofing compound, all as specified as directed. |
| 14 | Demolition of brick or stone boulder masnory, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facing, dressed stonework and percast concrete articles, complete all as specified and directed. |
| 15 | M&L for Brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean redius, built in 1:6 cement mortar, complete all as specified and directed. |
| 16 | M&L Brick work with sub class \"B\"brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wallcomplete all as specified & directed. |
| 17 | Taking down cement plaster on brick orstone masonry Including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed. |
| 18 | M&L for 15 mm thick cement plaster in 1:4 on facia, surface finished even and fair without using extra cement including applying Two coats of Premium acrylic emulsion paint including priming coat of exterior primer after preparation of new plastered surfaces complete all as specified & directed. |
| 19 | M&L for 15 mm thick cement plaster in 1:4, surface finished even and fair without using extra cement including applying Two coats of cement base paint including priming coat after preparation of new plastered surfaces complete all as specified & directed. |
| 20 | Taking up or down Steel Tubing 15mm bore (dia) with Fittings/ Connections, segregating Serviceable Pipes and Fittings/ Connections and keep in Safe Custody for re-use, complete all as specified and as directed. |
| 21 | Fixing Steel Tubing 15mm bore (dia) and Fittings in New or Old Position, (Serviceable Pipes and Fittings obtained from Item No. 20 here-in-before) after cleaning Inner and Outer surfaces of Pipes by using of Wire Brush including provision of New GI Fittings (as required), complete all as specified and as directed. |
| 22 | M&L Galvanised Tubes 15mm bore (dia), \"medium grade\", with all Fitting and fixed complete to Walls and Ceilings or laid in Floors, complete all as specified and as directed. |
| 23 | Taking up or down Steel Tubing 20mm bore (dia) with Fittings/ Connections, segregating Serviceable Pipes and Fittings/ Connections and keep in Safe Custody for re-use, complete all as specified and as directed. |
| 24 | Fixing Steel Tubing 20mm bore (dia) and Fittings in New or Old Position, (Serviceable Pipes and Fittings obtained from Item No. 23 here-in-before) after cleaning Inner and Outer surfaces of Pipes by using of Wire Brush including provision of New GI Fittings (as required), complete all as specified and as directed. |
| 25 | M&L Galvanised Tubes 20mm bore (dia), \"medium grade\", with all Fitting and fixed complete to Walls and Ceilings or laid in Floors, complete all as specified and as directed. |
| 26 | Taking up or down Steel Tubing 25mm bore (dia) with Fittings/ Connections, segregating Serviceable Pipes and Fittings/ Connections and keep in Safe Custody for re-use, complete all as specified and as directed. |
| 27 | Fixing Steel Tubing 25mm bore (dia) and Fittings in New or Old Position, (Serviceable Pipes and Fittings obtained from Item No. 26 here-in-before) after cleaning Inner and Outer surfaces of Pipes by using of Wire Brush including provision of New GI Fittings (as required), complete all as specified and as directed. |
| 28 | M&L Galvanised Tubes 25mm bore (dia), \"medium grade\", with all Fitting and fixed complete to Walls and Ceilings or laid in Floors, complete all as specified and as directed. |
| 29 | S&F in repairs15 mm bore Stop Valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union, complete all as specified and as directed. |
| 30 | S&F in repairs 20 mm bore Stop Valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union , complete all as specified and as directed. |
| 31 | S&F in repairs 25 mm bore Stop Valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union, complete all as specified and as directed. |
| 32 | S&F in repairs 150 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with and including clamps, nut bolts including dismantling of old AC rain water pipe etc in repairs complete all as specified and as directed. |
| 33 | S&F in repairs 150 mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 34 | S&F in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with and including clamps, nut bolts including dismantling of old AC rain water pipe etc in repairs complete all as specified and as directed. |
| 35 | S&F in repairs 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 36 | S&F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with and including clamps, nut bolts including dismantling of old AC rain water pipe etc in repairs |
| 37 | S&F in repairs 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 38 | Disconnecting existing water tank of exc 250 ltr and not exc 500 ltr Capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified and as directed.. |
| 39 | Disconnecting existing water tank of exc 500 ltr and not exc 1000 ltr Capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified and as directed. |
| 40 | Dismantling water tank of 500 ltr Capacity complete all as specified and ditected. |
| 41 | Dismantling water tank of 1000 ltr Capacity complete all as specified and ditected. |
| 42 | S&F Rotational Moulded Polyethylene 500 Ltrs Capacity three layer water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball brass valve, with polythelene float three layer external and internal white and fly nut complete screwed down for iron pipe of 20 mm dia all as specified anddirected. . |
| 43 | S&F Rotational Moulded polyethylene 1000 Ltrs Capacity three layer water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball brass valve, with polythelene float three layer external and internal white and fly nut complete screwed down for iron pipe of 20 mm dia all as specified anddirected. . |