| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth asdirected: All kinds of soil |
| 2 | Ordinary Rock |
| 3 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil |
| 4 | Ordinary Rock |
| 5 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres::All kinds of soil : |
| 6 | Ordinary rock |
| 7 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil : |
| 8 | Ordinary or hard rock |
| 9 | Dismantling G.I. pipes (external work) including excavation and refillingtrenches after taking out the pipes, manually/by mechanical meansincluding stacking of pipes within 50 meters lead as per direction ofEngineer-in-charge : Above 40 mm nominal bore |
| 10 | Laying and fitting of G.I. pipes (all classes) complete excluding cost of pipes, fittings and Earth work:- 65 mm dia G.I pipe |
| 11 | 50mm dia G.I pipe |
| 12 | 40mm dia G.I pipe |
| 13 | 25mm dia G.I pipe |
| 14 | 20mm dia G.I pipe |
| 15 | 15mm dia G.I pipe |
| 16 | Providing and fixing of 12mm thick M.S flangesG.I pipe incld. Cost of flanges, rubber gaskets, nuts bolts, welding charges cutting of threads excld. Earth work and refilling: 65mm dia |
| 17 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions incld. Tailpeices ,tapers, Gi pipeetc. complete50mm dia |
| 18 | 25mm dia G.I |
| 19 | Providing and fixing of CI sluice valve with cap including all accessories like nuts, bolts rubber insertion etc and tail pieces of Kirloskar make including successful testing and commissioning.100mm dia |
| 20 | 80mm dia |
| 21 | 65mm dia |
| 22 | Making connection of G.I. distribution branch with G.I. main offollowing sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete 25 to 40 mm nominal bore |
| 23 | 50 to 80 mm nominal bore |
| 24 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 50 mm nominal bore |
| 25 | 65mm dia |
| 26 | Constructing masonry Chamber of specified size, in brick work with common burnt clay (non modular) bricks of class designation 7.5 incement mortar 1:4 (1cement :4 coarse sand) and R.C.C. top slab 1:1.5:3mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mmnominal size ) including necessary xcavation, foundation concrete1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40 mmnominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.For sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid.Chamber 120x120x100 cm |
| 27 | Dumping stone including cost of stones. in Horizontal on level |
| 28 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating eachdeposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m |
| 29 | Providing and laying of Baramulla stones of approved size and texture incld. All sorts of carriage |
| 30 | Providing and laying of filter media (gravel) to be laid in layers as per specification and site incharge incld. Testing and all sorts of carriage |
| 31 | Providing & laying stone soling in horizontal on level. |
| 32 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 33 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 34 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 35 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 36 | Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with:-1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 37 | Providing & fixing of main hole cover 0.75 x 0.75 of standard quality with angle iron frame incld all necessary fittings complete |
| 38 | Providing & fixing of main hole cover 0.90 x 0.90 of standard quality with angle iron frame incld all necessary fittings complete |
| 39 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 40 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all completeWelded |
| 41 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 42 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 43 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 44 | Suspended floors, roofs, landings, balconies and access platforms |
| 45 | Lintel, beams, plinth beams, girders, bressumers and cantilevers |
| 46 | Arches, domes, vaults upto 6 m span |
| 47 | Extra for shuttering in circular work |
| 48 | Edges of slabs and breaks in floors and walls : Under 20 cm wide |
| 49 | Columns, pillars, piers, abutments, posts and struts. |
| 50 | Providing and fixing of 50mm dia G.I half bend of standard quality to be fixed in dome for aeration purpose |
| 51 | Providing and incorporating PGI sheets strips 0.8mm thick at construction joints incld. All carriages complete job |
| 52 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 53 | 12mm Cement plaster finished with a floating coat of neat cement of mix:1:3 (1 cement 3 sand) |
| 54 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge. Made of G.I. wire of dia 4 mm |
| 55 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 56 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 57 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness)including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses,string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills,fillets etc upto floor V level, including curing but excluding the cost of centring, shutteringand finishing with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 58 | Applying priming coat:- With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel work (second coat) |
| 59 | Painting with aluminum paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 60 | Providing and fixing of nuts ,bolts and chips incld one end fix to anchor block |
| 61 | Providing & fixing of 80mm dia PVC pipe for aeration purpose |
| 62 | Providing and mixing water proofing material in cement concrete work in doses by weight of cement as peranufacturer’s specification. (1 kg of water proofing material in 50 kg of cement) |
| 63 | Welding, including transportation of plant at site etc. complete By electric plant |
| 64 | Provision for Providing and fixing of pipe specials of standard quality incld. testing complete |
| 65 | Carriage of materials from source to road site of work including loading , unloading and stacking:-- Stone / stone soling for an av lead of 15 km |
| 66 | 40mm aggregate for an av lead of 45 km |
| 67 | 20mm aggregate for an av lead of 45 km |
| 68 | sand for an av lead of 30km |
| 69 | Pipes for an av lead of 15km |
| 70 | cement for an av lead of 15 km |
| 71 | steelfor an av lead of 15 km |
| 72 | Carraige of materials fromroad siteto site of work by manual labour including loading , unloading and stacking for an av lead of 300 Mtrs. Stone / stone soling |
| 73 | 40mm aggregate |
| 74 | 20mm aggregate |
| 75 | sand |
| 76 | pipes |
| 77 | Cement |
| 78 | Steel |
| 79 | Providing, erecting and fixing of sign board 2\"6\"\"x4\" made up of angle iron frame work 50x50x6mm with 1mm thick M.S sheet including priming, paintingand proper lettering and embeding with 1:3:6 cement concrete complete job |