| 1 | Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under: |
| 2 | Private car, auto-rickshaw or similar with 1.0 km lead |
| 3 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 4 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 5 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 6 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 7 | Extra per kilometer for lead >30.0 kms upto 50.0 kms |
| 8 | Extra per kilometer for lead >50.0 kms upto 70.0 kms |
| 9 | Load carrier auto, mini van or similar with 1.0 km lead |
| 10 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 11 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 12 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 13 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 14 | Extra per kilometer for lead >30.0 kms upto 50.0 kms |
| 15 | Extra per kilometer for lead >50.0 kms upto 70.0 kms |
| 16 | Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead |
| 17 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 18 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 19 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 20 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 21 | Extra per kilometer for lead >30.0 kms upto 50.0 kms |
| 22 | Extra per kilometer for lead >50.0 kms upto 70.0 kms |
| 23 | Dismantling of 415V 3-ph Voltage Stabilizer by way of opening of top lid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling. |
| 24 | upto 50 kVA |
| 25 | >50 upto 100kVA |
| 26 | >100kVA upto 250 kVA |
| 27 | Assembling of all parts of 3-ph Voltage Stabilizer, connecting of leads of all incoming and outgoing connections and refilling of old drained out of T. Oil |
| 28 | upto 50 kVA |
| 29 | >50 upto 100kVA |
| 30 | >100kVA upto 250 kVA |
| 31 | greater than 250 kVA |
| 32 | Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. |
| 33 | >60 upto 200 HP |
| 34 | Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian Oil Servo/ HPCL) |
| 35 | Filtration of existing/ reclaimed T-oil at suitable temperature (inclusive of all logistics and charges for filtration plant, etc)(Process loss maximum of 5% allowed) |
| 36 | Rewinding burnt/ damaged windings of voltage stabilizer coil assembly (comprising of three limbs) using superior quality copper wire of proper gauge as per requirement with superior insulation.(Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates). |
| 37 | 10kVA rating |
| 38 | 30kVA rating |
| 39 | 50kVA rating |
| 40 | 75kVA rating |
| 41 | 100kVA rating |
| 42 | 150kVA rating |
| 43 | 175kVA rating |
| 44 | 200kVA rating |
| 45 | 250kVA rating |
| 46 | Removing of damagedplate type voltage regulator switch from 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new plate type voltage regulator switch having copper contact points with 6 steps. the job includes cost on account of skilled/semi-skilled labour required for work |
| 47 | 10kVA rating |
| 48 | 30kVA rating |
| 49 | 50kVA rating |
| 50 | 75kVA rating |
| 51 | 100kVA rating |
| 52 | 150kVA rating |
| 53 | 175kVA rating |
| 54 | 200kVA rating |
| 55 | 250kVA rating |
| 56 | Providing and replacement of copper contact points on regulator plate |
| 57 | Impregnation/heat treatment ofwinding assembly of 3 phase, 415 ±15 % Volt voltage stabilizerby way of keeping it in an electric oven for about 24 hours and at approperate temperature. |
| 58 | 10kVA rating |
| 59 | 30kVA rating |
| 60 | 50kVA rating |
| 61 | 75kVA rating |
| 62 | 100kVA rating |
| 63 | 150kVA rating |
| 64 | 175kVA rating |
| 65 | 200kVA rating |
| 66 | 250kVA rating |
| 67 | Removing of damaged copper connection terminal bolt with washer and nut from3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new copper connection terminal bolt with nut and washer. |
| 68 | 10kVA rating |
| 69 | 30kVA rating |
| 70 | 50kVA rating |
| 71 | 75kVA rating |
| 72 | 100kVA rating |
| 73 | 150kVA rating |
| 74 | 175kVA rating |
| 75 | 200kVA rating |
| 76 | 250kVA rating |
| 77 | 500kVA rating |
| 78 | Hiring of portable welding set /soldering equipment etc. excluding power charges |
| 79 | Arresting of leakage in, 3 phase , 415 ±15 % Volt voltage stabilizer tank along with radiator fins/tubesby way of soldering/ welding at the cracked spot (average length of spot = 1 inch) |
| 80 | Providing and fitting of New MUG after removing old damaged MUG starter. |
| 81 | MUG 6, 6-10 Amp relay |
| 82 | MUG 6, 9-14 Amp relay |
| 83 | MUG 10, 13-21 Amp relay |
| 84 | MUG 10, 20-32 Amp relay |
| 85 | MUG 10, 28-42 Amp relay |
| 86 | MUG 15, 11-18 Amp relay |
| 87 | MUG 15, 13-22 Amp relay |
| 88 | MUG 20, 9-14 Amp relay |
| 89 | MUG 20H, 20-32 Amp relay |
| 90 | MUG 20H, 28-42 Amp relay |
| 91 | MUG 30, 20-33 Amp relay |
| 92 | MUG 30, 30-50 Amp relay |
| 93 | MUG 40, 30-50 Amp relay |
| 94 | MUG 40, 36-60 Amp relay |
| 95 | MUG 50,36-50 Amp relay |
| 96 | MUG 50, 45-75 Amp relay |
| 97 | MUG 75, 45-75 Amp relay |
| 98 | MUG 75, 66-110 Amp relay |
| 99 | Poviding and fitting of 3-Pole Contactor assemblyfor MUG - submersible starters |
| 100 | L&T, MU1 |
| 101 | L&T, MU1H |
| 102 | L&T, MU2 |
| 103 | L&T, MU3 |
| 104 | L&T, MK1 |
| 105 | L&T, ML2W |
| 106 | L&T, ML3W |
| 107 | L&T, ML4 W |
| 108 | L&T, ML6W |
| 109 | Providing and fitting of contactor kit set toMUG submersible starter |
| 110 | L&T, MU1 |
| 111 | L&T, U1H |
| 112 | L&T, MU2 |
| 113 | L&T, MU3 |
| 114 | Providing and fitting of Relay for FASD ,MUG Submersible starters |
| 115 | MK1 11-18 |
| 116 | MK1 13-22 |
| 117 | MU1 |
| 118 | MU2 9-14 A |
| 119 | MU2 13-21 A |
| 120 | MU2 15-25 A |
| 121 | MU220-32 A |
| 122 | MU2 24-38 A |
| 123 | MU2 28-42 A |
| 124 | MN5 20-33 |
| 125 | MN5 30-50 |
| 126 | MN5 36-60 |
| 127 | MN5 45-75 |
| 128 | MN5 66-110 |
| 129 | Providing and fitting ofSingle phase Preventer of MUG Submersible Staters. |
| 130 | L&T, Sz5 |
| 131 | L&T, SDz5 |
| 132 | Providing and Fitting of Terminal Block |
| 133 | 30 A-5way |
| 134 | 60 A-3 way |
| 135 | 100 A-3 way |
| 136 | 125 A-3way |
| 137 | Indicating lamps for MUG starters |
| 138 | Indicating lamp Red 415 V |
| 139 | Indicating lamp Greeen 415 V |
| 140 | Spare lamp, MR-G Controller |
| 141 | Rocker switch for MUG Starter |
| 142 | Rocker switch (for MU-G6 to MU-G20) |
| 143 | Rocker switch (for MU-G30 to MU-G75) |
| 144 | Voltage selector switch |
| 145 | Volt-Ammeter for MUG Starter |
| 146 | Volt-Ammeter 500V 30A |
| 147 | Volt-Ammeter 500V 60A |
| 148 | Volt-Ammeter 500V 0-75A |
| 149 | Volt-Ammeter 500V 0-100A |
| 150 | Volt-Ammeter 500V 0-125A |
| 151 | 30A Ammeter Spare for MR-G Controller |
| 152 | Volt Ammeter (30A, 300V AC) for 3-30 sec or 12-20 sec. |
| 153 | Electronic star -Delta timer for MUG Starters |
| 154 | Electronic star -Delta timer type ST100, 160 - 500V, for 3-30 sec or 12-20 sec. |
| 155 | Providing and fitting of MU Coil 240/360/415 V to MUG submersible Starter |
| 156 | Providing and fitting of MU1/MU1H/MU2/MU3 contact bridge |
| 157 | Providing and fitting of MU1/MU2 Relay extention nob to MUG submersible starter |
| 158 | Providing and fitting of MU1/M,U1H/MU2/MU3housing To MUG submersible starter |
| 159 | Providing and fitting of MU1 Single moving contact to MUG Submersible starter |
| 160 | providing and fitting of MU1H Single moving contact to MUG Submersible starter |
| 161 | providing and fitting of MU2 Single moving contact to MUG Submersible starter |
| 162 | providing and fitting of MU3 Single moving contact to MUG Submersible starter |
| 163 | Electronic star -Delta |
| 164 | Providing and fitting of New MCCB thermal release type |
| 165 | 100 A25 KA 3 pole |
| 166 | 100 A36 KA 4 pole |
| 167 | 160 A50 KA 3 pole |
| 168 | 160 A50 KA 4 pole |
| 169 | 200 A50KA 3 pole |
| 170 | 200 A50KA 4 pole |
| 171 | 250 A50KA 4 pole |
| 172 | 400 A50KA 4 pole |
| 173 | 630 A50KA 4 pole |
| 174 | Providing and fitting of 3-pole contactor (AC-3 duty) with specified coil voltage: |
| 175 | L&T ML 2 |
| 176 | L&T ML 3 |
| 177 | L&T ML 4 |
| 178 | L&T ML 6 |
| 179 | L&T ML 12 |
| 180 | L&T MNX 50 |
| 181 | L&T MNX 70 |
| 182 | L&T MNX 80 |
| 183 | L&T MNX 95 |
| 184 | L&T MNX 110 |
| 185 | L&T MNX 140 |
| 186 | L&T MNX 185 |
| 187 | L&T MNX 225 |
| 188 | L&T MNX 250 |
| 189 | Providing and fitting of new coil with specified coil voltage for contactors as under: |
| 190 | 9A to 45A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) |
| 191 | L&T ML 2/ 3 |
| 192 | L&T ML 4/ 6 |
| 193 | L&T ML 10/ 12 |
| 194 | L&T MNX 50/ 60/ 70 |
| 195 | L&T MNX 80/ 95/ 110 |
| 196 | L&T MNX 140/ 185/ 225 |
| 197 | Providing and fitting of new Contact kit set for contactors |
| 198 | 32A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) |
| 199 | L&T ML 2 |
| 200 | L&T ML 3 |
| 201 | L&T ML 4 |
| 202 | L&T ML 6 |
| 203 | L&T ML 10 |
| 204 | Providing and fitting of auxillary/ control relay (L&T MX0 or similar) for AC control |
| 205 | Providing and fitting of auxillary/ control relay (L&T MN0 or similar) for DC control |
| 206 | Providing and fitting of (1NO+1NC) side mounting auxillary contact block(For L&T/ Schneider Electric make contactors). |
| 207 | Providing and fitting of front mounting auxillary contact block having 04 contacts (all combinations)(For L&T/ Schneider Electric/ Siemens make contactors) |
| 208 | Providing and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Schneider/ Rishabh/ AE) |
| 209 | Providing and fitting of flush type analog moving iron AC meter as under:(Make: Rishabh/ AE/ C&S/ BCH) |
| 210 | 48x48mm 500V voltmeter |
| 211 | 96x96mm 500V voltmeter |
| 212 | 144x144mm 500V voltmeter |
| 213 | 96x96mm ammeter (5A CT operated) |
| 214 | Providing and fitting of flush type frequency meter with range 45-55Hz:(Make: Rishabh/ AE/ L&T/ Schneider/ BCH) |
| 215 | Providing and fitting of LED phase indicator with surge protection (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) |
| 216 | Providing and fitting 3 Phase, 3/4 Wire adjustable Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent) |
| 217 | Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make) |
| 218 | 50V or less unbalance & 1 C/ODIN mounted |
| 219 | 50V or less unbalance & 1 C/OPanel wall mounted |
| 220 | 70V or less unbalance & 2 C/ODIN mounted |
| 221 | Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make) |
| 222 | Providing of HRC fuses (2A - 32A) ratings |
| 223 | Providing and fitting of Fuse holders for fuses upto 32A rating |
| 224 | Providing and fixing PVC panel trunking with cover |
| 225 | 15x15mm |
| 226 | 25x25mm |
| 227 | Providing and fitting of Terminal Block 100A - 3 way |
| 228 | Providing and crimping of various aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: |
| 229 | 16 sq. mm |
| 230 | 25 sq. mm |
| 231 | 35 sq. mm |
| 232 | 50 sq. mm |
| 233 | 70 sq. mm |
| 234 | 95 sq. mm |
| 235 | 120 sq. mm |
| 236 | 150 sq. mm |
| 237 | 185 sq. mm |
| 238 | Providing and crimping of various copper tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: |
| 239 | 16 sq. mm |
| 240 | 25 sq. mm |
| 241 | 35 sq. mm |
| 242 | 50 sq. mm |
| 243 | 70 sq. mm |
| 244 | 95 sq. mm |
| 245 | 120 sq. mm |
| 246 | 150 sq. mm |
| 247 | 185 sq. mm |
| 248 | Providing,fitting of submersible cable of below mentioned specifications |
| 249 | 6 sqmm |
| 250 | 10 sqmm |
| 251 | 16 sqmm |
| 252 | 25 sqmm |
| 253 | 35 sqmm |
| 254 | Providing and fitting ofPVC iinsulated copper cable as per IS 694-along with thimbling as per requirments |
| 255 | Size:16 sq.mm1 core LT 1.1KV |
| 256 | Size:25 sq.mm1 core LT 1.1KV |
| 257 | Size:35 sq.mm1 core LT 1.1KV |
| 258 | Size:50 sq.mm1 core LT 1.1KV |
| 259 | Size:70 sq.mm1 core LT 1.1KV |
| 260 | Size:95 sq.mm1 core LT 1.1KV |
| 261 | Providing and Fitting of 2 core, 3 core, 3.5-Core, XLPE, 1.1KV and 11KV grade Armoured Aluminum Cable of various sizes conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. |
| 262 | 10 sq mm, 2 core LT 1.1 kv |
| 263 | 35 sq mm, 3 core LT 1.1 kv |
| 264 | 35 sq mm, 3.5 core LT 1.1 kv |
| 265 | 50 sq mm, 3.5 core LT 1.1 kv |
| 266 | 70 sq mm, 3.5 core LT 1.1 kv |
| 267 | 95 sq mm, 3.5 core LT 1.1 kv |
| 268 | 120 sq mm, single core LT 1.1 kv |
| 269 | Providing and fitting of new 4-pole, 415 V manually operated on load change over switch in open execution the job includes extraction of existing ones |
| 270 | 63 A |
| 271 | 100 A |
| 272 | 125 A |
| 273 | 160 A |
| 274 | 200 A |
| 275 | 250 A |
| 276 | 315 A |
| 277 | 400 A |
| 278 | 630 A |
| 279 | Providing and fitting of new 4-pole, 415 V manually operated on load change over switchfitted in sheet metal Enclusure duly power painted, vermin proof with side operating handle the job includes extraction of existing ones |
| 280 | 63 A |
| 281 | 100 A |
| 282 | 125 A |
| 283 | 160 A |
| 284 | 200 A |
| 285 | 250 A |
| 286 | 315 A |
| 287 | 400 A |
| 288 | 630 A |
| 289 | Providing and fitting of new 4-pole, 415 V manually operated off load change over switchfitted in sheet metal Enclusure duly power painted, vermin proof with side operating handle the job includes extraction of existing ones |
| 290 | 63 A |
| 291 | 100 A |
| 292 | 125 A |
| 293 | 160 A |
| 294 | 200 A |
| 295 | 250 A |
| 296 | 315 A |
| 297 | 400 A |
| 298 | 630 A |
| 299 | Providing and fitting of PVC insulated 1100V flexible copper cable (FRLS) for electrical installations as under (Preferred makes: Finolex/ Anchor/ L&T/ Havells/ KEI/ Polycab) |
| 300 | 1.0 sqmm |
| 301 | 1.5 sqmm |
| 302 | 2.5 sqmm |
| 303 | 4.0 sqmm |
| 304 | 6.0 sqmm |
| 305 | 10.0 sqmm |
| 306 | 16.0 sqmm |
| 307 | 2x1.5 sqmm |
| 308 | 2x2.5 sqmm |
| 309 | 2x6 sqmm (Aluminium unarmoured) |
| 310 | Providing and installation of SPN sheet steel enclosed Distribution boxes - Single door (Make: L&T/ Legrand/ Hager/ Havells/ Benlo) |
| 311 | 4 way |
| 312 | 8 way |
| 313 | 12 way |
| 314 | 16 way |
| 315 | Providing and installation of ‘B’ Series MCB 240V, 50Hz, 10kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider) |
| 316 | 6-32A SP |
| 317 | 40A SP |
| 318 | 6-32A DP |
| 319 | 40A DP |
| 320 | 100A 4P isolator |
| 321 | Providing and installation of Change over switches of metal enclosure 240v 50Hz (Preferred make: Anchor/ SSK/ Havells/ L&T) |
| 322 | 2-pole 16A 415V |
| 323 | 2-pole 32A 415V |
| 324 | 4-pole 32A 415V |
| 325 | Providing and installation of Busbar chamber 3-ph 4 bar heavy duty copper strips with rating as under(Preferred make: Havells/ SSK/ L&T) |
| 326 | 63A 415V |
| 327 | 100A 415V |
| 328 | 200A 415V |
| 329 | Supplying and laying 25mm X 5mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. |
| 330 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 331 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess with GI saddles and allied fittings for connections etc. as required. |
| 332 | Credit value for scrap copper |
| 333 | Hiring charges of Skilled Electrician (for fiiting of various substation itemsetc): |
| 334 | Hiring charges of Labourer for support of electrician. |