Supply Of Walk In Cold Room , Ppgi Puf Filled Panels As Per Spec No 3, 17 , Pcc Concrete Flooring 1:2:4 At Floor Stand ( 1 Cement: 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) , Flooring Of Walkincold Room As Per Spec No. 5 , Door With Hinges And Emergency Safetylock Size 900Mmx2000mm As Per Spec No 4 , Emergency Alarm With Standard Length Of Cable As Per Spec No 4 , Two 5Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Copper Pipes For Refrigeration Unit Additional Requirement , Drain Pipe Additional Requirement , Cables For Refrigeration Unit Additional Requirement , Control Panel With Switches And Alarm As Per Spec , Vapour Proof Lamp 2Nos With Cables And Switches As Per Spec No 14 , External Light With Cables And Switches As Per Spec No 14 , Digital Data Recorder With Temperature Alarm And Sms Alert Facility For Temperature Alarm As Per Spec No 12, 13 , Ss 304 Grade 14 Gauge Shelves 6X3 Feet As Per Spec No 22 , Ss 304 Grade 14 Gaugeshelves 5X3 Feet As Per Spec No 22 , Ss 304 Grade 14 Gauge Shelves 4X3 Feet As Per Spec No 22 , Pvc Blinds For Door Way As Per Spec No 23 , Earthing And Safety Equipments:Supply And Providing Pipe Earthing As Per Is 3043 With 3.60M Long 40Mm Dia B Class Gi Pipe, Gi Funnel With Weld Mesh, Filling Requried Quantity Of Charcoal & Salt Including Construction Of Inspection Chamber With A Bed Concrete Of 1:4:8 Pcc Using 40Mm Broken Stone ( 10Cm Thick ) , Brick Work In Cement Mortar 1:6, Plastering The Surface Of Brick Masonry And The Exposed Surface Of Pcc Bed With Cement Mortar 1:4, 12Mm Thick, ( The Finished Inside Dimension Shall Be 300X300x300mm ) But Excluding Test Joint, Earth Continuity Conductor To The Plate, And Covering At The Top ( In Ordinary Soil ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required.4.00 Mm Copper Conductor ( 8 Swg ) , Door With Hinges And Emergency Safetylock Size 1000Mmx2000mmas Per Spec ( Not Taken For Evaluation ) , Emergency Alarm Cable Additional Requirement ( Hooter ) , Two 3Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 4Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 6Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 8Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Additional Digital Display Unit As Per Spec With Standard Length Of Cables As Per Spec , Automatic 3 Phase Change Over , Cable For Additional Digital Display Unit , Demolition Of Old Walkincold Room , Mcbs And Mcb Distribution Boards:Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Busbar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Colour Washing Etc. As Required. 4 Way ( 8+12 ) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator / Rccb / Rcbo As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supplyand Fixing Of Following Rating Residual Current Circuit Breaker Having Earth Leakage Protection ( Rccb ) As Per Specification As Required4 Pole 63 Amps. ( 415 Volts ) , 100Ma Sensitivity , Supply And Fixingof Following Rating, 10 Ka, Miniature Circuit Breakers Of The Following Series As Required.6 A To 32 A Tp Mcb, C-Curve Mcb , Supply And Fixingof Following Rating, 10 Ka, Miniature Circuit Breakers Of The Following Series As Required.6 A To 32 A Sp Mcb, C-Curve Mcb , Sp Mcb Blanking Plate , Cables And Cabling : Supply Of Following Size 1.1 Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Aluminium / Copper Conductor Cable Conforming To Is 7098 ( Part 1 ) Amended Upto Date.4 C 16 Sq.Mm Al , Supply Of Following Size 1.1 Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Aluminium / Copper Conductor Cable Conforming To Is 7098 ( Part 1 ) Amended Upto Date.3 C 10 Sq.Mm Al , Supplying And Making End Termination With Brass Compression Gland And Aluminium / Copper Lugs For Following Size Of Xlpe Insulated Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade As Required-4C 25 Sqmm Sq.Mm Al , Laying And Clamping Of 1No. Pvc Insulated And Pvc Sheathed Armoured Power Cable, 1.1Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages Colour Washing Etc. As Required 4 Core Cable Of Size Exceeding 6Sq.Mm But Not Exceeding 25 Sq.Mm With Company Fabricated Saddles. , External Over Head Canopy For 2 Outdoor Units If The Compressor Units Are Placed In Open Area , Stablizer 15 Kva 3 Phase Wide Range As Per Spec