| 1 | `EXTERNAL LIGHTING FEEDER PILLAR:SITC Of free standing suitable for out door installation dust and vermin proof feeder pillar made out ofCRCA sheet ,required hard ware,duly painted by either two coats of zink /red oxide primer followwed by two coats of synthetic enmel paint for powder coating in grey or required shade . The feeder pillar having Neoprene rubber gasket of not less than 3mm thickness,hingled door with locking arrangement,gland plate.Thickness of sheet shall not be less than 2mm.Sheet metal works shall be processed with seven tank process,200A TPN 415V Electrolytic Cu Conductor bus bar with 100% Neutral (Fixed on 50x50x6mm thick MS Angle iron frameand covered with sheet metal from all sides)and having the following components.Incoming :One (1) No. 100A 4P MCCB (25KA) Busbar :Electrolytic high conductivity Copper three pole and 100%neutral bus bars rated at 200 amps having a maximum current density of 1 amp per sq mm insulated with heat shrinkable PVC sleeves and SMC/DMC supports.Outgoings : Ten(6) Nos. 10 A-32ADP 10KA MCBs. with 10A-32A DP contactor (AC 1 Category with 230V Control Coil) using 1 No. 24 hour astronomical time switch on Auto/Manual arrangement with Auto/Manual selection switch, ON/OFF Push Buttons, Indication lamps and Control fuses etc.Eight (6) Nos. 40 A 4P 10KA MCBs.with 40A 4P contactor (AC 1Category with 230V Control Coil) using 1 No. 24 hour astronomical time switch on Auto/Manual arrangement with Auto/Manual selection switch, ON/OFF Push Buttons, Indication lamps and Control fuses etc` |
| 2 | `LIGHTING FIXTURES .Supply installation testing and commisioningofhighly efficient front -openable IP 66 with 45W LED streetLight with aluminium pressure die cast housing,toughened glass in the front and peanut lens for batwing light distribution to ensure uniform light distribution and having high power LED`s Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) 120Lumens/watt,Life of fixture (Including Driver) : 50K Hrs. @ L70 Lumen maintenance, CCT 3000 - 6500K, CRI )80, PF )0.90 , an operating Voltage Range of 120 - 277 V.Minimum Internal Surge Protection 5KV The fixture design should comply with IS10322,EMC / EMI compliance maintaining driver leakage current as per as per IEC 60598,Minimum system Lumens 5400. LuminaireSuitable for operation from -10 to 35Deg C etc. complete as required` |
| 3 | Supplying and erection of street bracket made of G.I Pipe `A `class suitable of suitable length and dia,the pipe bended to give angle of 100 to 115 degree fitted with 65mmdia cape of suitable depth,bolt,and nuts at the top of existing pole including painting the pipe with two coats of approved pait over priming coat comlete in all respects and as per directions of Engineer -in-charge. |
| 4 | Supplying ofthe following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor / copper conductor power /multicore power armoured cable of 1.1 KV grade 4 CX16sq mm Copper conductor XLPE insulatedarmoured cable |
| 5 | Supplying ofthe following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor / copper conductor power /multicore power armoured cable of 1.1 KV grade 4 CX10sq mm Copper conductor XLPE insulated armoured cable |
| 6 | Supplying ofthe following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor / copper conductor power / multicore power armoured cable of 1.1 KV grade 3 CX6sq mm Copper conductor XLPE insulatedarmoured cable |
| 7 | Supplying ofthe following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor / copper conductor power / multicore power armoured cable of 1.1 KV grade 4CX25sq mm Alluminium conductor XLPE insulatedarmoured cable |
| 8 | Supplying ofthe following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor / copper conductor power / multicore power armoured cable of 1.1 KV grade 3.5CX240sq mm Alluminium conductor XLPE insulatedarmoured cable |
| 9 | Supply, installation Testing and commissioning of LED Step Light 7w with Pressure Die cast aluminium housing for strudiness, excellent corriosion resistant andefficient thermal managememnt with grey finish having clear poly carbonate cover for Better Ingress protection ( IP66) having SMD LED with efficacy of140lm/w CRI)90, and viewing angle of 120 degree to ensure better uniformity of light distribution, built in potted electronic driver with APFC ( SMPS basedconstant current supply) lower THD and open circuit protection as per IS 15885 part-2 Sec 13, having lumen O/P of 180 lumen, CRI)80, PF)0.95, THD(10%. Havells Cat No: RADIANT FTR07W LED830PSYMTOPC Or equivalent to Philips or Wipro |
| 10 | Supply installation and Testing of LED Spike Light 15w with grey pure polyster powder coated, pressure die cast aluminium housing for efficient thermalmanagement with High efficient COB LED Mounted on MCPCB of fixture, Lumen Efficacy of lED)140lm/w with Tougned Glass built in, built in potted electronicdriver with APFC ( SMPS based constant current supply) lower THD and open circuit protection as per IS 15885 part-2 Sec 13, having lumen O/P of 180 lumen, CRI)80,PF)0.95, THD(10%. Havells Cat No: LYCUSSPS15W LED730PSYMBOTG or Equivalent to Philips or Wipro |
| 11 | - Supply installation and Testing of IP - 67,LED flexi ble LED Strip light_ 36 W Havells Cat No: FLEXISTRIP 36 W or Equivalent to Philips or Wipro |
| 12 | Supply installation and Testing of LED Spike Light 25w with grey pure polyster powder coated, pressure die cast aluminium housing for efficient thermalmanagement with High efficient COB LED Mounted on MCPCB of fixture, Lumen Efficacy of lED)140lm/w with Tougned Glass built in, built in potted electronicdriver with APFC ( SMPS based constant current supply) lower THD and open circuit protection as per IS 15885 part-2 Sec 13, having lumen O/P of 180 lumen, CRI)80,PF)0.95, THD(10%. Havells Cat No: LYCUSSPS15W LED730PSYMBOTG or Equivalent to Philips or Wipro |
| 13 | Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |