Supply Installation Testing And Commissioning And Replacement Of Unserviceable / Condemned Air Conditioning Units At Lbs Hospital, Khichripur Delhi.-2 Supplying, Installation, Testing & Commissioning Of Split Type Ac Unit Inverter Type Of 2.0Tr - 2, delhi-Delhi

Public Works Department has published Supply Installation Testing And Commissioning And Replacement Of Unserviceable / Condemned Air Conditioning Units At Lbs Hospital, Khichripur Delhi.-2 Supplying, Installation, Testing & Commissioning Of Split Type Ac Unit Inverter Type Of 2.0Tr - 2. Submission Date for this Tender is 13-06-2022. Clamps Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

32540781
Supply Installation Testing And Commissioning And Replacement Of Unserviceable / Condemned Air Conditioning Units At Lbs Hospital, Khichripur Delhi.-2 Supplying, Installation, Testing & Commissioning Of Split Type Ac Unit Inverter Type Of 2.0Tr - 2
Open Tender
Indian
Delhi
Delhi
13-06-2022

Tender Details

Supply Installation Testing And Commissioning And Replacement Of Unserviceable / Condemned Air Conditioning Units At Lbs Hospital, Khichripur Delhi.-2 Supplying, Installation, Testing & Commissioning Of Split Type Ac Unit Inverter Type Of 2.0Tr - 2.20Tr With Cooling Capacity Not Less Than 7000 Watt / 6000 K.Cal / Hr. Complete With Outdoor Condensing Unit & Wall Mounted Evaporating Unit Having Cordless Remote Control, Copper Refrigerant Pipe Line Upto 4 Meter Length, Capable Of Cooling, Filtering & Dehumidifying, Suitable For Operation On 230Volt 1-Ph. Ac Supply ( 5 Star Rating Model As Certified By Bee ) With Mountings / Fittings For Indoor / Outdoor Units, Insulating The Suction Pipe With Epf Tubing, Leak Test , Charging Refrigerant Including Providing Electrical Wires Within 4 Meter Of Location Of Unit Complete As Required. 3 Supplying, Installation, Testing & Commissioning Of Split Type Ac Unit Inverter Type Of 1.5Tr With Cooling Capacity Not Less Than 5200 Watt / 4500 K.Cal / Hr. Complete With Outdoor Condensing Unit & Wall Mounted Evaporating Unit Having Cordless Remote Control Refrigerant Pipe Line Upto 4 Meter Length, Capable Of Cooling, Filtering & Dehumidifying, Suitable For Operation On 230Volt 1-Ph. Ac Supply ( 5 Star Rating Model As Certified By Bee ) With Mountings / Fittings For Indoor / Outdoor Units, Insulating The Suction Pipe With Epf Tubing, Leak Test , Charging Refrigerant Including Providing Electrical Wires With In 4 Meter Of Location Of Unit Complete As Reqd. At Site Of Work. 4 Supplying, Installation, Testing & Commissioning Of Window Type Ac Unit Of 1.5 Trwith Cooling Capacity Not Less Than 5200 Watt Complete With Condensing Coil Evaporating Coil Of Cooling, Filtering & Dehumidifying, Wooden Frame, Ply For Blocking The Space Etc. Suitable For Operation On 230Volt 1-Ph. Ac Supply ( 5 Star Rating Model As Certified By Bee ) As Reqd. At Site Of Work. A ) 1.5 Tr Capacity 5 Supplying And Laying Of One Number Xlpe Insulated And Fr Pvc Round Sheathed, Un-Armoured, Copper Conductor Power Cable Of 1.1 Kv Grade Conforming To Is : 694 Of Following Sizes Forelectrical Connection Of Indoor And Outdoor Units For Extend Main Supply Of 1.5 / 2.0 Tr Split Type Ac As Required. A ) 4 X 2.5 Sq. Mm 6 Sitc Of Following Kva Capacity Single Phase, 230 Volts, Automatic Voltage Stabilizer Complete With High-Low Cut Off And Time Delay Relay Etc As Required. 7 A ) 5Kva Range 130-280V 8 B ) 4Kva Range 170-270V 9 Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. 10 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 11 A ) 3 X 4 Sq. Mm 12 Supply, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft / Hard Drawn Copper Refrigerant Piping For Vrv / Vrf System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing / Brazing Including Accessories, Insulated With Xple Class-O Tubular Insulation / With Class-O Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of Specified Thickness As Given Below For Suction And Liquid Lines, All Accessories As Per Specifications Etc. As Required : 13 15.86 Mm Dia ( Od ) ( Soft Drawn ) With Tube Thickness 1.2 Mm With 19 Mm Thick Insulation 14 6.4 Mm Dia ( Od ) ( Soft Drawn ) With Tube Thickness 1.2 Mm With 19 Mm Thick Insulation 15 Supplying And Fixing 25 Mm Flexible Drain Pipe Suitable For Split And Window Ac Units Complete With Necessary Clamping On Wall / Floor For Support Etc. As Per Site Requirement. 16 Sub Head-Ii ( Credit ) 17 Credit Of Unserviceable Split Ac Unit Of 1.5 / 2.0 Tr Capacity At Site I / C Dismantling 18 1.5 Tr Capacity Window Ac 19 1.5 Tr / 2Tr Capacity Split Ac

Key Value

Document Fees
Refer document
EMD
INR 19793.0 /-
Tender Value
INR 9.89 Lakhs /-
Disclaimer :