| 1 | Supply, Laying, jointing & testingin trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 16 sqmm 4 core with all fixing & connecting accessories including taking down old unserviceable cable.NOTE :- Excavation and earth work shall be measured and paid separatly |
| 2 | All as per Item No 1 here-in-before but35 sqmm 3.5 core. |
| 3 | All as per Item No 1 here-in-before but50 sqmm 3.5 core. |
| 4 | All as per Item No 1 here-in-before but95 sqmm 3.5 core. |
| 5 | All as per Item No 1 here-in-before but120 sqmm 3.5 core. |
| 6 | Material and labour in replacement of alluminium cable thimbles of size 120 Sqmm UG Cable including complete connection and crimping. |
| 7 | All as per Item No.6 above but 95 Sqmm. |
| 8 | All as per Item No.6 above but 50 Sqmm. |
| 9 | All as per Item No.6 above but 35 Sqmm. |
| 10 | All as per Item No.6 above but 25 Sqmm. |
| 11 | Supply and fixing in replacement LED Street light 120 Watt (lumen efficeincy >130 lm/W) CCT 5700K New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED aslight source and Impact Resistance IK07 ,suitable for 50-56mm dia GI bracket with all necessary connection complete all as specified and directed. |
| 12 | Supply and fix in replacement Off load change over switch 200 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handel operated complete all as directed by Engr In Charge. |
| 13 | Supply and fix in replacement On load change over switch 100 amps 415 volts 4 pole 50 Hz open execution type with rotary type handel operated complete all as directed by Engr In Charge. |
| 14 | Supply and fix in replacement MCCB 4 pole adjustable type 250 amps ruptering capacity 36 KA for 415 volts complete as directed by Engr In Charge. |
| 15 | Supply and fix in replacement MCCB 4 pole adjustable type 200 amps ruptering capacity 36 KA for 415 volts complete as directed by Engr In Charge. |
| 16 | Supply and fix in replacement MCCB 4 pole adjustable type 160 amps ruptering capacity 36 KA for 415 volts complete as directed by Engr In Charge. |
| 17 | Supply and fix in replacement MCCB 4 pole adjustable type 100 amps ruptering capacity 36 KA for 415 volts complete as directed by Engr In Charge. |
| 18 | Dismantling and taking out self starter assembly suitable for 62.5 KVA DG Set and replacement of wornout spare parts like field coil, armature assembly, solenoid assembly, corbon brush, corbon brush assembly, clutch plate assembly and bushes including servising and refixing to engine complete all as specified. |
| 19 | Supply and fix in replacement stop solenoid 12V 10 amps single coil 75mm dia cat part No - 02.477.01.0.00 |
| 20 | Supply and fix replacement generator control unit KG541 level-0 cat part No - D8.048.07.0.00 |
| 21 | Dismantling and taking out battery charging alternater assembly suitable for 62.5 KVA DG Set and replacement of wornout spare parts like field coil, rotor assembly, corbon brush, rectifier assembly and bushes etc including servisingand refixing complete all as specified. |
| 22 | Supply and fix replacement exhaust fan (450mm) with connector cat part No -D8.079.26.0.00 |
| 23 | Dismantling and taking out fuel injector pump assembly suitable for 62.5 KVA DG Set and complete overhauling of FIP including replacement of unserviceable parts like rebuild overhauling kit, rebuild seal kit, fuel injector \"O\" rings, OEM gaskets, spring gasket injector, valve bearing etc complete all as specified. |
| 24 | Taking down radiator from the engine and refixing after cleaning washing and soldering to leaking water tubes including 2 ltrs of coolant complete |
| 25 | Taking out Turbocharger and replacement of Compressor Housing,Compressor Wheels,Turbine housing,Turbine Wheel,Wastegate Acuator with clamps,setting, caleberation and testing complete |
| 26 | Repair, servicing and comprehensive maintenance ofDG Sets of any make of the following capacities incl replacement of defective /burn out parts by new parts such as filters,gaskets,V belts,Engine oil , rubber hoses,cleaning of alternator by vacuum cleaner and greasing of bearing with cother connected work for the cap62.5 kVA Make : Kirloskar/cummins/Mahindra Powerol complete all as specified and directed by Engr-in-charge. Note: Labour charge for :--- (ii) Periodical routine maintenance to be carried out as per the periodicity as under :-(a) The cost of fixing of all components/parts and trasportation of DG sets spare parts from site to workshop and vice versa shall be deemed to be included in the unit rates.(b) Cost of oiling, greasing , tightening of nut, bolts & minor extra are included in the unit rate quoted by the contractor. NOTE: Supply only of Spare parts required for repair/maint will be measured & paid separately under relavent items. |
| 27 | All as per Srl Item No 26 but of cap30 kVA of any Make & type |
| 28 | All as per Srl Item No 26 but of cap10-15 kVA of any Make& Type |
| 29 | Supply only air filter element Suitable for Kirloskar 4R1040T model / Mahindra Powerol 62.5 kVA capacity |
| 30 | Supply only air filter element Suitable for Kirloskar/ Mahindra Powerol 30 kVA capacity |
| 31 | Supply only air filter element Suitable for Kirloskar/ Mahindra Powerol 10-15 kVA capacity |
| 32 | Supply only Fuelfilter element Suitable for Kirloskar 4R1040T model / Mahindra Powerol 62.5 kVA capacity |
| 33 | Supply only Fuelfilter element Suitable for Kirloskar/ Mahindra Powerol 30 kVA capacity |
| 34 | Supply only Fuelfilter element Suitable for Kirloskar/ Mahindra Powerol 10-15 kVA capacity |
| 35 | Supply only Lub oilfilter element Suitable for Kirloskar 4R1040T model / Mahindra Powerol 62.5 kVA capacity |
| 36 | Supply only Lub oilfilter element Suitable for Kirloskar / Mahindra Powerol 30 kVA capacity |
| 37 | Supply only Lub oilfilter element Suitable for Kirloskar/ Mahindra Powerol 10-15 kVA capacity |
| 38 | Supply only Banded cogged belt (2JAX51-LP-1326) cat part No - 06.032.03.0.00 |
| 39 | Supply only V Belt (A-47) 1227 length cat part No - 04.140.01.0.00 |
| 40 | Supply only Fuel pipe (7.5, 14x14B, 700 PB) cat part No - 34.151.04.0.00 |
| 41 | Supply only Silencer assembly cat part No - 48.318.10.0.00 |
| 42 | Supply only Rubber hose for air intake cat part No - 48.464.02.0.00 |
| 43 | Supply and Fixing Kirloskar green AVR for alternator 62.5 KVA DG set (Model: TAVR-10/TAVR-20/TAVR-14) cat part No - 2H.811.32.0.00 |
| 44 | Supply & pouring in sump/topping up of Engine oil of grade 15W-40/20W-50 in engine or replacement of EngineMake - Servo/Castrol/IOCL/HPCL |
| 45 | Material and labour in replacement coolant for radiator of any make any type DG set at various loactions all as directed by Engr-in-charge |
| 46 | Disconnecting incoming / outgoing cable connection from alternator of 63/62.5 kVA DG set and taking out from DG set room checking carefully and transporting to auth workshop for repair and rewinding of alternator dismentling into parts and cutting the burnt/damage copper winding wire from alternator / stator cleaning slots and rewinding the stator/alternator with super enamelled copper winding wire of existing gauge & size and insulation paper etc complete varnishing of rewinded alternator replacement of carbon brush set bearing set etc complete and transporting the alternator to DG set room coupling with DG set and testing complete include water load test all as specified and directed by Engr-in-charge.NOTE: All neccessary T&P for dismantling,transporting and installation cost is deemed in this work |
| 47 | Supply and Fix in replacement factory assembled hermatically sealed unit compresor for window /split type AC of capacity 1.5 TR of approved make and capacity suitable for 230 V, single phase , AC , 50 Hz electric, nuts complete including charging the system with suitable refrigerent gas as per OEM and testing complete to achieve desired coolingall as specified and directed.Make :- Whirpool/Godrej/LG/kirloskar/TecomushNote:-The rate quoted by the contractor shall include the cost of taking out old unserviceable compressor and provision of new factory made assembled compressor duly charged the with refrigerent gas as per OEM. |
| 48 | Servicing of Refrigerator/Deep freezer of any capacity complete with chemical solutionto condenser & cooling coil, cleaning of entire elements of AC, oiling/greasing to motor, including tracing out the leaking of condenser/evaporator filling the holes by using gas welding, complete with refilling of refrigerant R12/R11/R134a(whichever is applicable) etc complete all as specified and as directed. |
| 49 | Diconnecting the input and output electric supply from automatic voltage stabiliser of any capacity and taking out from Palma and shifting to civil workshop Rajouri (about 35 KMs away from Palma) for carrying out repair works.Note:- The rate quoted by the contractor shall incude the rate for T&P, transportation and necessary men power required during loading and unloading. |
| 50 | Opening the top cover of votage stabiliser taking out the complete servo stabiliser oil and keep it for reuse and taking out dimmer assembly and transformer assembly for checking the defects. |
| 51 | Supply and fix in replacement Dimmerstate unit of capacity 50 KVA servo voltage stabilizer 28 amps of Make Volina complete all as specified and directed. |
| 52 | Supply and fix in replacement main transformer of capacity 50 KVA servo voltage stabilizer of make Volina complete all as specified and directed. |
| 53 | Supply and fixing in replacement Electronic circuit board (Printed circuit board) for controlling of synchronous motor of torque 10 KG and auto/manual under voltage high voltage operation. |
| 54 | Supply and fix in replacement PCB holder. |
| 55 | Supply and fixing in replacement trigger transformer. |
| 56 | Supply and fixing in replacement panel lamps alongwith connecting leads for over voltage under voltage etc. |
| 57 | Supply and fix in replacement corbon brush. |
| 58 | Supply and fix in replacement digital volt meter 72 x 72mm. |
| 59 | supply and fixing in replacement servo motor 10 KG torque. |
| 60 | Supply and fixing in replacement RC network for 10 KG servo motor |
| 61 | Supply and fix in replacement auto manual switch. |
| 62 | Dismantling and taking out ceiling fan 230 volts 1200/1400mm sweep any make cutting the old burnt winding rewinding with new super enamelled copper wire as existing guage including insertion of insulating papers threading and insulating with insulating warnish, lathe work, replacement of 2.25/3.15 MFD capacitor, replacement of MS split clamp 02 nos with rubber reelcomplete all as specified and as directed. |
| 63 | Supply and fixin in replacement of ball bearing of size 6200 to 6204 suitable for ceiling fan 1200/1400mm sweep. Make :- NBC/SKF |
| 64 | Supply and fix in replacement water heater storagesuitable for 35 ltr storage type water heater complete all as specified and as directed. |
| 65 | Material and labour for filling in with new transformer oil for top up to voltage stabilizer having low viscosity of approved make as per IS 355 of 1992 and di-electric strength 40 KV(after filtration) complete all as specified and directed by Engineer-in-Charge. Make : Savita/Castrol |
| 66 | Taking out submersible pump and motor of capacity 5 HP from the tube well lowered at the depth of 90 to 110 mtr from the ground level including taking out GI flanged column pipes 40mm bore of 03 metre length each (column pipe are provided with flanged joints at every 03 metre length) and one Nos submersible cable 3 core of any size incl disconnecting electrically and delivery out let pipe and lowering after complete repair and maint of the same complete as in order to start the submersible pump complete all as directed by Engr-in-charge |
| 67 | Rewinding submersible motor 5 HP of03 Phase, 415 voltswith PVC insulated solid copper conductor (wire) superior quality of approved make, size & number of wire as per existing complete including replacement of worn out cable connectionsincluding testing and commissioningof motor after rewinding complete all as specified.Make of Motor : KSB |
| 68 | Supply only the following spare parts for submersible motor as per existing make and size :- Make of motor KSB |
| 69 | (a) GM Bearing Bush |
| 70 | (b) Rotor sleeve |
| 71 | (c) Water seal |
| 72 | (d) Thrust bearing |
| 73 | (e) Housing upper |
| 74 | (f) Housing lower |
| 75 | (g) Cable seal |
| 76 | (h) Thrust plate |
| 77 | (j) Coupling S/S |
| 78 | (k) Key for coupling |
| 79 | (l) LNK bolt S/S |
| 80 | (m) Revolving disc |
| 81 | (n)Seal bush |
| 82 | (p) Sand guard |
| 83 | Opening and reassembling of submersible pump of capacity 5 HP and replacement of the worn out spare parts as mentioned under respective item no 66 here in after. Make of pump: KSB |
| 84 | Supply only the following spare parts forsubmersible pump as per existing make and size :- Make of pump KSB |
| 85 | (a) Stage bowl |
| 86 | (b) Impellers |
| 87 | (c) Pump shaft S/S (single stage) |
| 88 | (d) Hook bolt (Upper & lower) |
| 89 | (e) GM neck ring |
| 90 | (f)Key for pump shaft (Each stage) |
| 91 | (g) Distance sleeve |
| 92 | (h) D.O.L Bush |
| 93 | (j) Sand guard |
| 94 | (k) Impeller key |
| 95 | (l) Inter ring |
| 96 | (m) Guide bush |
| 97 | (n) Suction chamber |
| 98 | (p) D.O.L. Sleeve |
| 99 | Dismantling of existing defective induction motor of thesize 5 HP capacity any makefrom the foundation, disconnecting the electric connection, coupling pulley, and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with super enamelled solidcopper conductor ( winding wire) complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed by Engineer-in-Charge. |
| 100 | Excavation in trenches in any type of soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / layingunder ground electric cable or for pole etc complete all as specified and as directed. |
| 101 | Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cms in depth in soft/loose soils complete all as specified and as directed. |
| 102 | Removing surplus soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point all complete as specified and as directed. |
| 103 | Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge. |
| 104 | Brick clay (old size brick )with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat all as directed. |
| 105 | Supply & Fix in replacement Single phase submersible pump set controller /starter for upto 2 HP submersible pump set with suitable cap starting & running capacitors complete Make: L&T Model MU-G6 DOLTechnocommetially ABB/kirloskar |
| 106 | Supply & Fix in replacement Exhaust fan PVC body white colour AC single phase 230/240V of size 200 mm sweep with louvers. |
| 107 | Deduction to be made from BOQ for schedule of credit (Sch \"A\" Part - II) Amount of ? 16,227.00during AOCNote:- Tenderers shall not quote for this Schedule |