Supply, Installation, Testing And Commissioning Of Vfd And Misc. Tools For Water Supply And Drainage System At Na, Gidc, Ankleshwar-A Chain Pipe Wrench ( 900 Mm ) B Aluminum Handle Pipe Wrench ( 95 Mm ) C Extension Bar 6 D Rachet Handle E Screw Driver Set F Grease Gun G Ring Type Spanner Set ( 6X7 To 30X32 ) H Rechet Set I Double End Spanner Set ( Ribbed ) ( 32X36 To 50X55 ) J Double End Spanner Set ( Ribbed ) ( 50X55 To 75X80 ) K Double End Spanner Set ( Ribbed ) ( 6X7 To 30X32 ) L Spirit Level M Allen Key N Allen Key O Universal Joint P Clamp Meter ( 3-314 Digital 6000 Count, 2000A Dc / Ac Trms Meter ) Q Clamp Meter ( 3-314 Digital 4000 Count, 1000A Dc / Ac Trms Meter ) R Insulation Tester ( 5 Kv ) S Hammer Type 3 Gear Drill Machine T Grinder ( Cordless Angle Grinder ) U Drum Lifter V Plastic Tool Box With Organizer W Bosch Gdx 18 V-Ec Professional Cordless Impact Wrench X Bosch Impact Wrench Gds 30 Professional Y Bosch Wet / Dry Extractor Gas 35L Z Hydraulic Crimping Tool In-Built Pump Type. Suitable For Electric Cables And Conductors. Capacity – 16 Ton Stroke – 24 Mm Dies: 16 To 400 Mm2, Total-12 Dies. ( 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 Mm2 ) Weight: 15 Kg. Aa Non-Contact Laser Digital Thermometer With Lcd Screen Ab Digital Vibration Meter Ac Digital Laser Measurement Meter Up To 40 Mtr Range 2 Supplying Erecting, Commissioning Of 415 V Fully Automatic Microprocessor Based Variable Frequency Drive For Pump Control Application As Per General Specification As Under The Vfd Unit Shall Have Modular Construction, 6 Pulse Bridge Rectifier, Speed Control By Means Of Sensor Less Vector Control ( Open Loop ) , High Torque At Low Frequencies, Locking At High And Low Frequency Settings, In-Built Pid Control, Frequency Accuracy Of ±.01% ( Min ) , Frequency Resolution Of ±.01% Hz ( Min ) , Protection Against; A ) Over Load ( Motor And Drive ) , B ) Short Circuit, C ) Ground Fault, D ) Input / Output Phase Loss ( Open Circuit ) , E ) Stalling, F ) Input / Out Put Under Voltage ( Momentary Power Loss Restart ) , G ) Input / Output Over Voltage, H ) Over Frequency, I ) Input Surge, J ) Over Temperature Of Heat Sink, K ) Loss Of Remote Speed Signal Etc. The Vfd Shall Also Have User-Friendly Programming Software & It Shall Be Capable Of At Least Two Level Parameter Setting With Password Lock For Critical Parameters, Programming For I / Os, Speed Search Function, Copy Parameters ( Unload / Download ) To Other Identical Unit, Tuning To Energy Saving Mode ( Maximum Efficiency ) , Event / Fault Recording ( Last 5 Faults In Non-Volatile Memory ) & Rs485 Communication Port ( Modbus Rtu Protocol ) With Required Software. A 90 Kw B 110 Kw 3 Sitc Of 37.5 Kw Rating Star Delta Lv Mcc Panel Totally Enclosed, Dust & Bermin Proof, Indoor Type, Minimum Degree Of Protection - Ip 52 As Per Is: 2147, Operation On 3- Phase, 4 Wire, 415 V, 50 Hz, Neutral Effectively Grounded, With Instrumentation Compartments Accommodating Led Type Indicating Lamps, Control Contactors As Per Is: 13947, Ct Of Accuracy Class-1 As Per Is: 2705, Relays, Meters & Control Mcbs, Air Insulated Electrolytic Grade Aluminum Bus Bar For Three Phase & Neutral System With Incoming Breaker- Microprocessor Based Air Circuit Breakers ( Electrically Operated Draw Out Type ) / Air Break Fixed Type Mccb With Trip Free Mechanism, Current Limiting Type As Per Is : 8828, Motor Contractor ( As Per Type -2 Coordination ) , Overload Relay With Built-In Single Phasing Prevention Feature & Auxiliary Feeders As Per Sld Drawings, Momentary Contact Type Push Buttons, Equipment Fittings, Bus Bars, Cable Boxes, Cable Gland, Incoming & Outgoing Cable Connection For 1100 V Grade, Aluminum / Copper Conductor Xlpe / Pvc Insulated & Pvc Sheathed Armoured Cable, 10 % Spare Terminals, Power Wiring Using 1100V Grade, Frls Insulated Copper Conductor Wires Conforming To Is: 694 & 8130, Cable Compartments / Alleys Of Minimum 300 Mm Size, Gi Earth Bus Bar For Entire Length. Mcc Shall Be Fabricated From Cold Rolled, Coled Annealed ( Crca ) Sheet Steel & Minimum Thickness Of Various Members Shall Be As Follows: Base Frame / Channel / Glant Plate -3 Mm Load Bearing Memners / Doors-2 Mm And Internal Partitions-1.6 Mm With Auto Transformer Starter With Mccb, Contactor, O / L Relay, Cast Resin Type Ct, Digital Mfd, Analog Ammeter, Spp, Time Etc. Size Of Panel Canopy Not Less Than 700 X 450 X 800 Mm 4 Providing And Supply Lt Distribution Panel For K.M. Hall Having Specifications: Panel Dimensions :-1500Mm ( H ) *1000 Mm ( W ) *400Mm ( D ) 2 Partition ( 600Mm+400Mm ) Moc: - 14 Gauge Crca Ms Powder Coated Main Incomer Power Supply:- 200-250 A 4P Mccb ( Du250c Type Make L&T ) With Spreader & Extended Rom. Change Over Switch: 200 A 4P Change Over Switch ( Co2 200 Type Make L&T ) With Wiring & Aluminum Bus Bar ( 40Mm*10Mm ) Out Going Circuit : 32A 4Pole Mcb - 04 Nos. 63A 4 Pole Mcb - 01 Nos 16 Sq.Mm Screw Terminal ( R-Y-B-N ) - 9 Set ( Total -36 Nos )