Repair / Replacement And Maint Of Electric Panels, Ug Cables And Connected Items At Dholewal Mil Complex Under Ge Ludhiana- Excavation In Trenches In Any Type Of Soil Not Exceeding 1.5 Mtr Wide And Not Exceeding 1.5Metre In Depth For Taking Out Of Unserviceable Under Ground Cable Complete All As Specified And Directed. 3 Returning, Filling In, Any Type Of Soil And Spreading, In Layers Not Exceeding 25 Cm Thick Complete All As Specified And Directed. 4 Removal Of Surplus Soil ( Any Type Of Soil Obtained From Excavation ) To A Distance Not Exceeding 50 Metre And Depositing Where Directed& Complete All As Specified And Directed . 5 Supplying And Laying Bricks Common Brunt Clay Building Bricks Sub Class Binclremoving Of Old Bricks Complete All As Specified And Directed. 6 M & L For Sand Cushioning In Trenchesand Well Ramming In Layers For Cable Cushioningwith Fine Dry Sand And Complete All As Specifiedand Directed.Notes-: ( I ) Excavation And Earth Work To Be Measured And Paid For Separately. ( Ii ) Thickness Of 18Cms After Punning Shall Be Considered For Payment. 7 Dismandling & Taking Down Of Existing Worn Out / Unserviceable Aluminium Conductor, Steel Reinforced ( Acsr ) Of Any Description / Size & In Any Position From Existing Lt Pole / Lines All As Specifiedand Directed. 8 Supply, Laying, Jointing, Testing And Commissioning In Replacement Of 16 Sqmm 4 Core Cable Xlpe Insulated , Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Laid In Trenches, On Pole Complete All As Specified And Directed. 9 Supply, Laying, Jointing, Testing And Commissioning In Replacement Of 35 Sqmm 3.5 Core Cable Xlpe Insulated , Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Laid In Trenches, On Pole Complete All As Specified And Directed. 10 Supply, Laying, Jointing, Testing And Commissioning In Replacement Of 50 Sqmm 3.5 Core Cable Xlpe Insulated , Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Laid In Trenches, On Pole Complete All As Specified And Directed 11 Supply, Laying, Jointing, Testing And Commissioning In Replacement Of 70Sqmm 3.5 Core Cable Xlpe Insulated , Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Laid In Trenches, On Pole Complete All As Specified And Directed 12 Supply, Laying, Jointing, Testing And Commissioning In Replacement Of 95 Sqmm 3.5 Core Cable Xlpe Insulated , Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Laid In Trenches, On Pole Complete All As Specified And Directed 13 Supply, Laying, Jointing, Testing And Commissioning In Replacement Of 120 Sqmm 3.5 Core Cable Xlpe Insulated , Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Laid In Trenches, On Pole Complete All As Specified And Directed 14 Supply And Fix Of Aluminium Lugs Uitable For 16 To 35 Sqmm 1100Volts Including Taking Down Old Unserviceable Lugs, Complete All As Specified And Directed . 15 Supply And Fix Of Aluminium Lugssuitable For 70 To 95 Sqmm1100volts Including Taking Down Old Unserviceable Lugs, Complete All As Specified And Directed. 16 Supply And Fix Of Aluminium Lugssuitable For 120 To 185 Sqmm1100volts Including Taking Down Old Unserviceable Lugs, Complete All As Specified And Directed . 17 Supply And Fixing In Replacment Gi Pipe Light Grade 40 Mm Bore For Cable Protection Fixed To Poles / Along Wall / Floor / Under Road / Across The Drain Or Nallah Including Taking Up Old Gi Pipe Complete All As Specified And Directed. 18 All As Per Ser Item No 16 Here-In-Before But Size 50 Mm Dia 19 Supply And Fixing In Replacment Gi Pipe Light Grade 80 Mm Bore For Cable Protection Fixed To Poles / Along Wall / Floor / Under Road / Across The Drain Or Nallahcomplete All As Specified And Directed. 20 Supply, Installng, Testing And Commissioning Floor Mounted Lt Panel Out Door Type Of Suitable Size Cubical Type Factory Made, Weather And Vermin Proof Made Out Of Crca Sheet 3.00 Mm Thick Appropriate Size Of Panel 1.2 X 1.2 X 0.45 M And Angle Iron Frame Of 50X50x6mm And 04 Nos Legs On Angle Iron 50X50x6mm Each 45 Cm Long Panel Duly Powder Coacted In Side And Out Side With 7 Tank Process Heaving Insulated Bus Bar Tpn With Openable Shutter On Both Side ( Front And Rear Side ) With Locking Arrangement Duly Pre-Wired With Suitable Size Of Copper Conductor Cable With Proper Size Of Copper Lugs / Thimbles And Connecting To Mccbs With Suitable Size Aluminium Strip Duly Bended And Fixed With Nut & Bolts And Washers From Bus Bar To Mccbs And Legs Grouted In Pcc 1:2:4 Type B:1 ( 20 Mm Graded Stone Aggregate ) With Gland Packing To Provided For Cable Approved Complete As Under:- ( I ) Aluminium Bus Bar Strip Of Capacity 320 Amps Fixed On Epoxy Insulator - 04 Nos ( Ii ) Incomming Mccb Of Current Rating 160 Amps With Adjustablethermal Release 4 Pole 415 Volts 36 Ka Repturing Capacity - 01 Nos.Make For Mccbs:- Havells / L & T / Abb / Hpl / Legreand ( Iii ) Out Goingmccb Of Current Rating 100 Amps Withadjustable Thermal Release 4 Pole 415 Volts 25 Ka Repturing Capacity - 01 Nos.Make For Mccbs:- Havells / L & T / Abb / Hpl / Legreand ( Iv ) Out Goingmccb Of Current Rating 63 Amps With Adjustable Thermal Release 4 Pole 415 Volts 16 Ka Repturing Capacity - 03Nos.Make For Mccbs:- Havells / L & T / Abb / Hpl / Legreand ( V ) Digital Voltmeter ( 0-500 Volt ) 96X96mm ( Vi ) Digital Ampmeter ( 0-600 Amps ) 96X96mm Incl With Ct, S ( Vii ) Set Of Phase Indicator Lamp R, Y, B With Control Mcb - 01 Set 21 Supply, Installng, Testing And Commissioning Floor Mounted Lt Panel Out Door Type Of Suitable Size Cubical Type Factory Made, Weather And Vermin Proof Made Out Of Crca Sheet 3.00 Mm Thick Appropriate Size Of Panel 1.2 X1.2 X0.45M And Angle Iron Frame Of 50X50x6mm And 04 Nos Legs On Angle Iron 50X50x6mm Each 45 Cm Long Panel Duly Powder Coacted In Side & Out Sidewith 7 Tank Process Heaving Insulated Bus Bar Tpn With Openable Shutter On Both Side ( Front And Rear Side ) With Locking Arrangement Duly Pre-Wired With Suitable Size Of Copper Conductor Cable With Proper Size Of Copper Lugs / Thimbles And Connecting To Mccbs With Suitable Size Aluminium Strip Duly Bended And Fixed With Nut & Bolts And Washers From Bus Bar To Mccbs And Legs Grouted In Pcc 1:2:4 Type B:1 ( 20 Mm Graded Stone Aggregate ) With Gland Packing To Provided For Cable Approved Complete As Under:- ( I ) Aluminium Bus Bar Strip Of Capacity 400 Amps Fixed On Epoxy Insulator - 04 Nos ( Ii ) Incomming Mccb Of Current Rating 200 Amps With Adjestable Thermal Releasetype 4 Pole 415 Volts 36 Ka Repturing Capacity - 01 Nos.Make:-L&T / Legrand / Schenider / Abb / Havells ( Iii ) Out Goingmccb Of Current Rating 100 Amps With Adjestable Thermal Releasetype 4 Pole 415 Volts 16 Ka Repturing Capacity - 02 Nos.Make:-L&T / Legrand / Schenider / Abb / Havells ( Iv ) Out Goingmccb Of Current Rating 63 Amps With Adjestable Thermal Releasetype 4 Pole 415 Volts 16 Ka Repturing Capacity - 02 Nos. Make:-L&T / Legrand / Schenider / Abb / Havells ( Vi ) Digital Voltmeter 96X96m Squire Type With Inbuilt Selector Switch -01 Nos ( Vii ) Digital Ampmeter96x96m Squire Type With Cts Inbuilt Selector Switch -01 Nos ( Viii ) Set Of Phase Indicator Lamp R, Y, B - 01 Set 22 M & L For Earthing Incl Eath Workcomplete With Galvanised Steel Earth Plate Electrode 600X600x6mm Thick Burried Directly In Ground ( Earth Pit Not Less Than 2.25 Meters Deep Below Ground Level ) With To Edge Of The Plate Not Less Than 1.5 Mtrs Below Normal Ground Level Connected To Galvanised Earth Lead 32X6mm By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron Or Steel Protected By Gi Pipe All As Shown In Electrical Pate No 5 Of Ssr Part I - 2009Connected To Earthing Test Point All As Specified And Indicated Including Excavation Earth Work Pcc Chamber Rcc Chamber Cover Protection Pipe Watering Pipe Funnel And Testing On Completion All As Specified And Directed. ( Note: Earth Strip And Protection Pipe Upto 7.50 M Length Is Included In The Unit Rate ) 23 M&L For Lt Straight Through 1100 Volt Grade Forcable For Heat Shrink Type Joint Kit Complete With Jointing Material And Accessories Suitable For 4 Core 25 To 50 Sqmm Xple Armoured Aluminium Conductor Cablecomplete All As Specified. 24 M&L For Lt Straight Through 1100 Volt Grade Forcable For Heat Shrink Type Joint Kit Complete With Jointing Material And Accessories Suitable For 4 Core 70 To 120 Sqmm Xple Armoured Aluminium Conductor Cablecomplete All As Specified. 25 M&L For Lt Straight Through 1100 Volt Grade Forcable For Heat Shrink Type Joint Kit Complete With Jointing Material And Accessories Suitable For 4 Core 150 To 185 Sqmm Xple Armoured Aluminium Conductor Cablecomplete All As Specified. 26 M & L For Sub Main Wiring Complete With 2 Runs Of 2.5 Sqmm Single Core Pvc Insulated Frls Cable 1100 Volts Grade Multistranded Copper Conductor Cable With 1 Run Of 2.5 Sqmm Single Core Pvc Insulated Frls Cable 1100 Volts Grade, Multistranded Copper Conductor Cable As Earth Continuity Conductor, Drawn Through And Including 25 Mm Or Higher Dia Non Metallic Rigid Pvc Conduit And Conduit Accessories Concealed / Surface In Wall / Ceiling Etc All As Specified And As Directed. Note:- Three Runs Of Cable Shall Be Measured As One Unit. 27 S& F For Polycarbonate Thermoplastic Outdoor Junction Box For Steet Lights With Flap Cover Operate With Iec 61439-3 Which Should Be Shock Proof, Protection Class-Ii, Earthed , Ip 65 Weather Proof , Corrision Free , Acid And Chemical Resistant , Impact Resistant, , Ultra Voilet Resustantmade Of Halogen & Silicone Free Recyclable Mtrl, Internally Embedded Gasket With Provision For Cable Entry Through Integrated Flanges Top And Bottom, The Gasket Should Be Internally Embedded Made Of Polycarbonate Incl With Fixing Arrangement ( Clamps, Nuts And Bolts Etc. ) Complete All As Specified. Make:- Hensel / Rittel / Schneider / Le-Grand. 28 Cutting Of Black Top Of Road For Laying Of Xlpe Ltcable 11000 Volt And After Laying Of Cable Repairing Of Road With Cement ( 1:2:4 ) , Concrate / Bituman Surface Complete All As Specified & Directed 29 M & Lfor 100 Mm Thick Pcc 1:3:6 Type C-2 Using 40Mm Crushed Stone Aggregatecomplete All As Specified And As Directed. 30 Dismandling Of Existingunserviceable Cross Armsof Any Descriptionand In Any Position Complete All As Specified And Directed. 31 M& L In Replacement For Cross Arms, Bracings, Supports Clamps And Back Plate Fabricated From Steel Structural Including Nuts, Bolts Washers Welding, Bending Cold Or Hot, Drilling Holes And Inclusive Of One Primer Coat, One Under Coat And One Finishing Coat Of Paint Complete All As Specified And Directed. 32 Dismandlingof Existingunserviceable Stay Assembly Of Any Sizeand In Any Position Complete All As Specified And Directed 33 M & Lin Replacement Stay Assembly Comprising Of Gi Stay Bow 14 Mm Dia, 40 Cm Long ( Over All ) Galvanised Stay Rod 16 Mmdia 215 Cm Long With Threaded Ends Gi Nuts, Bolts, Washers, Stay Plate 30 Cm X 30 Cm X 6 Mm Thick2 Nos Of Thimbles, Ms Clamps Made Out Of 50 Mm X 6 Mm Flat Iron Complete Including Stay Wire 7 / 8 Swg Complete All Assprcified And Directed Including Necessary Excavation And Earth Work And Pcc 1:3:6 All As Shown In Electrical Plat No.1 Of Ssr-1991 Part-I ( Pcc And Earth Work, Loop Type Insulator, Stay Clamps Shall Be Measured Andpaid For Separately Under The Respective Item Of Schedule ) Including Taking Down Existing Old Unsv Stay Assembly Complete All As Specified And Directed. 34 M & L For Danger Notice Plates Made Out Of 1.6Mm Thick Mild Steel Sheet, Vitreous Enamelled White Letters, Figures, And Conventional Skull And Bones In Signal Red Colour And Fixed With M.S. Clamps, Bolts And Nuts Of Approved Size, For Lt, 20X15cm Size Including Taking Down Existing Old Unsv Danger Notice Plate Complete All As Specified And Directed. 35 Supply And Fixing In Replacement Of Mccb Of Current Rating 400 Amps, 4 Pole, 415 Volts Ac, 36 Ka Rupturing Capacity With Adjustable Thermal Magnetic Typeincluding Taking Down Old Unsv Mccbs Complete All As Specified And Directed.Make:- Havells / Abb / Indo Asian / L & T. 36 Supply And Fixing In Replacement Of Mccb Of Current Rating 200 Amps, 4 Pole, 415 Volts Ac, 36 Ka Rupturing Capacity With Adjustable Thermal Magnetic Type Including Taking Down Old Unsv Mccbs Complete All As Specified And Directed. Make:- Make:- Havells / Abb / Indo Asian / L & T. 37 Supply And Fixing In Replacement Of Mccb Of Current Rating 160 Amps, 4 Pole, 415 Volts Ac, 36 Ka Rupturing Capacity With Adjustable Thermal Magnetic Typeincluding Taking Down Old Unsv Mccbs Complete All As Specified And Directed. Make:- Havells / Abb / Indo Asian / L & T. 38 Supply And Fixing In Replacement Of Mccb Of Current Rating 100 Amps, 4 Pole, 415 Volts Ac, 16 Ka Rupturing Capacity With Adjustable Thermal Magnetic Typeincluding Taking Down Old Unsv Mccbs Complete All As Specified And Directed.Make:- Havells / Abb / Indo Asian / L & T. 39 Supply And Fixing In Replacement Of Mccb Of Current Rating 63 Amps, 4 Pole, 415 Volts Ac, 16 Ka Rupturing Capacity With Adjustable Thermalmagnetic Type Release Including Taking Down Old Unsv Mccbs Complete All As Specified And Directed. Make:- Havells / Abb / Indo Asian / L & T. 40 M&L For Finding Lt Cable Fault Location By Man With Locator Machine ( Techno Instrumentation ) Complete All As Specified And Directed. 41 Supply And Fixfor Led Garden Light Fittings 10W, 240V, 50Hz, New Generation, Energy Saving, Environmental Friendly, Long Life, Asthetically Design Aluminium Landscape, Luminaire For Diffused Lightening Rated Input Ip-54, P.F- Not Less Then 0.95, Incl With Pcc ( 1:2:4 ) Foundation Higher Complete All As Specified And Directed.Make:- Havells / Cg / C&S / Philips.