Tender For Supply Of Equipment / Material , Design, Erection, Testing & Commissioning For Sop To T / Well Nerna At Vill. Nerna By Prov. 11 / .4 Kv 100 Kva S / Stn. A / W 11 Kv Ht Section Raja-Ka-Talab Under Esd Rehan Ed Fatehpur. ( Bid No. Ocd / Db / Bid-12 / 2022-23 ) - 11 / .4 Kv 100 Kva Distribution Sub Station 3 11 / .4 Kv 100 Kva Dtr ( Rec Sep. Ord 11 / 1976 4 Prov. St Polepole 9 Mtr. Long W / L 200 Kgs 5 Muff For Steel Tubular Pole With Concrete Filling 6 X-Arm: [ Channel Iron ( 100X50x5 Mm ) , Length : 2800 Mm X 2 Nos ] For Incomer Line 7 Ms A.I. ( 50X50x6 Mm ) , Length: 2800 Mm X ( 1 Nos For LaS ) 8 X-Arm: [ Channel Iron ( 75X40x5 Mm ) , Length : 2800 Mm X 4 Nos ] For Supporting Do Fuse Unit & Go Switch 9 X-Arm: [ Channel Iron ( 100X50x5 Mm ) , Length : 2800 Mm X 2 Nos ] For Transformer Bed 10 X-Arm [ Channel Iron ( 100X50x6 Mm ) , Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer ] 11 Ms A.I. ( 50X50x6 Mm ) , Length: ( 2800 Mm ) X 2 No. 12 Ms Angle Iron ( 35X35x5 Mm ) , Length : 460 Mm X 2 Nos 13 Ms A.I. ( 50X50x6 Mm ) , Length: ( 950 Mm ) X 2 Nos. Of Bed Knee Bracing 14 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 2800 Mm ) X2 Nos 15 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 450 Mm ) X1 Nos 16 G.O. Switch Handle Supporting: [ C.I. ( 75X40x6mm ) , Length: 460Mm 17 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 18 D.O Fuse Unit 19 Surge Arrester, 9 Kv Station Class 20 Discs Insulator Sets ( Comp. 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) I / C Dead End Clamps Etc. ) 21 Stay Set Complete 22 Staywire ( 7 / 3.15Mm ) ( 7 Kg Per Stay Set ) 23 Pipe Earthing With Gi, Charcoal & Salt 24 Prov. Lt Distribution Panel With Mccb ( 160 A, 10 Ka, 4P, 1 No. ) & Sfu ( 32 A 5 No. Rewireble ) For 100Kva Trf. As Per Specification 25 Half Clamp ( M.S. Flat 50X6 ) 26 Full Clamps ( M.S. Flat 50X6 ) 27 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 28 Aluminium Thimbles 29 Copper Thimble 30 Danger Plate 31 Barbed Wire ( Rec Sp F 3 / 1981 ) 32 Lt Cable 3-1 / 2 Core-120Mm Sq. 33 Alluminium Paint 34 Prov.Acsr, 6 / 1 / 3.35 Mm 35 Prov. Transformer Structure Protection Plinth ( Civil Work As Per Hpsr ) For 100Kva S / Stn 36 11 Kv Ht Line 37 Prov.11 Kv Abc ( 3X70+35Mm ) With Bare Massengerx2cables And Additional 1% ( Sagging, And Wastage } 38 Prov. Steel Tubular Poles. 9Mtrs 39 Muff For Steel Tubular Pole ( 2000Mm Long ) With Concrete Filling 40 Cross Arm: [ Channel Iron ( 100X50x6 Mm ) , Length 600 Mm ( I / C Tolerence Of 100Mm Either Side ) X2structurerun Through Structure ( Formation Tringle ) 41 Angle Iron ( 50X50x5 Mm ) , Length ( 2X750 ) Mm X 2 Structuresrun Through Structure ( Formation Tringle ) 42 Anchoring Assembly For Ht 43 Suspension Assembly For Ht 44 Facad Hook For Ht Heat Shrinkable Strait Through Jointing Kit 45 Heat Shrinkable Strait Through Jointing Kit 46 Cable Termination Kit 47 T-Jointing Kit 48 Belt Set - Ms Angle Iron: 50X50x6, Length [ 1800 Mm X 2 No. ] Dead End Structures: 49 X-Bracing Set - Ms Angle Iron: 50X50x6, Length [ 2125 Mm X2 No. ] Dead End Structures: 50 X-Arm ( Horizental ) - Ms C. Iron: 50X50x6, Length [ 2340 Mm X2 No. ] Dead End Structures: 51 Stay Set Complete In All Respect ( Single Pole-1No. , / D. Pole Structures-4Nos. ) 52 Stay Wire ( 7 / 3.15 Mm ) ( 8.0 Kg Per Stay Set ) 53 Ht Earthing Set Complete ( Rec Constr. Standared J-1 ) 54 Half Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 55 Full Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 56 Danger Plate ( 250X200x1.6 Mm ) 57 Barbed Wire ( Rec Sp F 3 / 1981 ) 58 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 59 D.O Fuse Unit 60 Alluminium Paint 61 Prov. Hp Make Aiq Desktop Model Hp 200 G4 With Intell Core 3-10110U-10 Gen.Processor, 8Gb Ddr4 Ram Expenditure Upto 16 Gb, Itb, Hdo ( T2qorpm ) 2St Antiglare Led Desplay Withfhd ( 1920X1060 ) Integrated Hd Graphics & Webcam, 2Xusb, 3.0 2Xusb, 2.0 Cardreacer. Audio Part Vgnhdmi / Dp Port, 10X100, 1000Mcomdliant Lan Usb Key Board & Mouse Internalspl. Connectivity Bo2 11 B / G / N / Ac Pl Windows Etc. With Three Years On Site Warranty. ( Ii ) 650Va Offline Ups System With12vx7ahx2nos: 158Vah / Smf Batteryto Povide20 Min. Battery Back Upwith Three Year Warrantyon Ups &Battery From Delivery With Printer