Hemodialysis Machine Nephrology Materails Satellite Hospital Mandore, Jodhpur , Drugs , Medicines & Other Items , Hemoconcentrate Part A & B- A. The Constituents Of The Hemoconcentrate Are As Follows: • Part-A ( Aqueous ) -Sodium Chloride: 160-170G / L; Potassium Chloride: 5-5.5G / L, Calcium Chloride: 8.5-9G / L; Magnesium Chloride: 5-5.50G / L; Glacial Acetic Acid: 8-9G / L And Qs Purified Water. ( When Diluted As 1:34 ) Sodium:75-85 Mmol / L, Potassium: 0-2Mmol / L, Calcium-1.70-1.75Mmol / L, Magnesium: 0.75-1Mmol / L, Chloride: 85-90Mmol / L, Acetate: 3.5-4.5Mmol / L. Part B- Each Powder Packet Weighing 800-900Gm Containing Sodium Chloride:200-300Gm, Sodium Bicarbonate: 500-650Gm Which Provides After Dissolving Sodium 55-60 Mmol / L, Chloride: 20-25Mmol / L; Bicarbonate: 30-40 Mmol / L. , Arterio- Venous Fistula Needle :One Pre-Sterlized Set Each With A Pair Of Needles, 16 Gauze Needle With Back Eye And Length 25-30Mm With Fixed Wings With Luer Lock In The Attached Blood Tubing Of Length 25-30Cm. , Dialyzer: Single Use Dialyzer For Hemodialysis Of Adultpatients Having Synthetichollow Fibre Of Polysulfone, Sterilized With Non Ethylene Oxide Method. It Should Be Able To Bear Blood Flow Of Minimum 200Ml / Min And Dialysate Flow Rate Of 500Ml / Min With Surface Area- 1.3-1.4M² ( Requirement: 100 / Month ) . , Dialyzer: Dialyzer For Hemodialysis Of Adultpatients Which Should Be Presterlized With Non Ethylene Oxide Method With And Reusable Having Synthetichollow Fibre Of Polysulfone Able To Bear Blood Flow Of Minimum 200Ml / Min And Dialysate Flow Rate Of 500Ml / Min With Surface Area-1.6-1.7 M² ( Requirement: 40 / Month ) Which Should Be Able To Be Rinsed Effectively For Reuse Post Hemodialysis. , Arteriovenous Line: It Should Be Supplied With Blood Tubing To Be Attached To The Dialyzer During Dialysis. The Length Of Pre Sterilized Latex Free Medical Grade Tubing Should Be 35-40Cm With Capacity Of Priming Volume Approximately 145-155Ml With Arterial Chamber, Venous Chamber With Respective Arterial And Venous Luer Locks And Injection Ports In The Tubing And Ends Of The Tubing Fitted With Suitable Connectors To The Access And Dialyzer. , Pediatric Dialyzer: The Pediatric Dialyzer Should Be Pre Sterilized By Non Ethylene Oxide Method And Made Of Synthetic Polysulfone Hollow Fibre With Surface Area 0.6 M² ( Requirement: 25 / Year ) , The Dialyzer And Arteriovenous Blood Line Of Same Manufacturer Would Be Preferred , Pediatric Dialyzer: The Pediatric Dialyzer Should Be Pre Sterilized By Non Ethylene Oxide Method And Made Of Synthetic Polysulfone Hollow Fibre With Surface Area 0.8M² ( Requirement- 150 / Year ) . The Dialyzer And Arteriovenous Blood Line Of Same Manufacturer Would Be Preferred. , Pediatric Arteriovenous Line ( Blood Tubing ) : The Pediatric Arteriovenous Blood Line Should Be Pre Sterilised And Latex Free With Arterial Chamber, Venous Chamber With Respective Arterial And Venous Luer Locks And Injection Ports In The Tubing And Ends Of The Tubing Fitted With Suitable Connectors To The Access And Dialyzer. The Dialyzer And Arteriovenous Blood Line Of Same Manufacturer Would Be Preferred. , Plasma Filter For Plasmapheresis: The Plasma Filter For Therapeutic Plasmapheresis In Renal Failure Patients Pre Sterilised Withpolysulfone / Polyethylene Membrane With Effective Surface Area- 0.5M²- 0.6 M² ( Requirement- 100 / Year ) , Double Lumen Catheter For Hemodialysis With Kit: The Double Lumen Catheter For Hemodialysis In Patients. It Should Be Pre Sterilized By Non Ethylene Oxide Method, Of Flexible Radio Opaque Polyurethane Material Make With J End Guide Wire ( Guidewire Must Be Of Good Quality ) , V Shaped Double Entry Introducer Needle, Vessel Dilator With Arterial And Venous Port Caps, Syringe 5-10Cc With Luer Lock. It Should Be Antimicrobial Coated. Size Of The Double Lumen Catheters To Be Supplied Are: A. 8F× 8-9Cm ( Requirement- 50 / Year ) . , Double Lumen Catheter For Hemodialysis With Kit: The Double Lumen Catheter For Hemodialysis In Patients. It Should Be Pre Sterilized By Non Ethylene Oxide Method, Of Flexible Radio Opaque Polyurethane Material Make With J End Guide Wire ( Guidewire Must Be Of Good Quality ) , V Shaped Double Entry Introducer Needle, Vessel Dilator With Arterial And Venous Port Caps, Syringe 5-10Cc With Luer Lock. It Should Be Antimicrobial Coated. Size Of The Double Lumen Catheters To Be Supplied Are: B. 11.5F-12F×13-14Cm ( Requirement- 50 / Month ) ; , Triple Lumen Catheter For Hemodialysis With Kit: The Triple Lumen Catheter For Hemodialysis In Patients. It Should Be Pre Sterilized By Non Ethylene Oxide Method, Of Flexible Radio Opaque Polyurethane Material Make With J End Guide Wire ( Guidewire Must Be Of Good Quality ) , V Shaped Double Entry Introducer Needle, Vessel Dilator With Arterial And Venous Port Caps, Syringe 5-10Cc With Luer Lock. It Should Be Antimicrobial Coated. Size Of The Triple Lumen Catheters To Be Supplied Are: C. 11.5F-12F×13-14Cm ( Requirement- 50 / Month ) ; , Biopsy Gun: Kidney Biopsy Gun With Size A. 16 Gauze×16Cm Needle ( Requirement- 100 / Yearwith Penetration Depth 18-22Mm, Pre Sterile, Automated Spring Loaded. Spring Quality Must Be Of Good Quality To Ensure Smooth Loading And To Prevent Misfire. , Biopsy Gun: Kidney Biopsy Gun With Size 18 Gauze×16Cm Needle ( Requirement- 50 / Year ) With Penetration Depth 18-22Mm, Pre Sterile, Automated Spring Loaded. Spring Quality Must Be Of Good Quality To Ensure Smooth Loading And To Prevent Misfire. , Peritoneal Dialysis Catheter: Kit To Include Pre Sterilised Rigid Peritoneal Dialysis Catheter With Single Cuff With Metal Stiletto With Pointed End, Scalpel With Holder, Connector With Flow Regulator. The Catheter To Be Supplied With Peritoneal Dialysis Fluid Administration Set. Peritoneal Dialysis Catheter With Administration Set ( Requirement- Adult—200 / Year; , Peritoneal Dialysis Catheter: Kit To Include Pre Sterilised Rigid Peritoneal Dialysis Catheter With Single Cuff With Metal Stiletto With Pointed End, Scalpel With Holder, Connector With Flow Regulator. The Catheter To Be Supplied With Peritoneal Dialysis Fluid Administration Set. Peritoneal Dialysis Catheter With Administration Set ( Requirement-; Pediatric-50 / Year ) . , High Concentrate Part A Hemodialysis Solution 1. High Concentrate A Hdsolution Compatible With Dry Bag Part B Powder. Company Must Be Iso & Gmp Certified. 2. Fluid Composition: Sodium 103 Mmol / L, Chloride 109.5 Mmol / L, Calcium 1.75 Mmol / L, Magnesium 0.5 Mmol / L, Potassium 2Mmol / L Presence Of Glucose In Hd Fluid Solution Is Optional. , Citrosteril- 5 Litre Cans. , 6% Sodium Hypochlorite- 5 Litre Cans , Acetic Acid Glacial- 5 Litre Cans , Citric Acid Monohydrate 500Gm. , Hydrochloric Acid- 5 Litre Cans , Injection Of Basiliximab 20 Mg , Rabbit Antithymoglobulin 250 Mg , High Flux Hemodialyzer With Tubing Specification: Non Ethylene Oxide Presterlyzed High Performance Membrane And Hollow Fiber Type. Ultrafiltration Coefficient ( Kuf ) Is >15 Ml / H / Mmhg And B2-M Clearance >15 Ml / Min. Compatible With Most Hemodialysis Machines. High Biocompatible Materials Such As Polysulfone. Housing Polycarbonate Or Polypropylene. Potting Compound Should Be Polyurethane. Priming Volume. Uf Coefficient. Clearance Data ( Urea, Creatinine, Phosphate, Vitamin B12 ) . Endotoxin Retaining Characteristics. Compatible With Most Reprocessing Machines And Reprocessing Fluid. Should Have Caps For Blood Inlet And Outlet Ports For Safer Storage. Dialyzers Should Meet European Ce Or Usfda An+H99d Iso Standards. Effective Surface Area 1.6-2.0 Sqm. Dialyzer Must Be Supplied With Compatible Tubing Set. , Purosteril Solution 5 Ltr. , Dry Bicarbonate Bag For Hemodialysis. 650 Gram