| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed. |
| 2 | All as per item No 1.00 above but depth exc 1.50m but n.exc 3.00m complete all as specified and directed. |
| 3 | All as per item No 1.00 above but depth exc 3.00m but n.exc 4.50m complete all as specified and directed. |
| 4 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar including concrete bedding and haunching complete all as specified and directed for 150mm bore of pipe |
| 5 | All as per Item No 4.00 above but 200 mm dia |
| 6 | S & F 150mm SGSW pipe ISI marked laid in trenches and jointed in CM (1:1) complete all as specified and directed. |
| 7 | S & F 200mm SGSW pipe ISI marked laid in trenches and jointed in CM (1:1) complete all as specified and directed. |
| 8 | M & L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in bed to drain pipe including packing under and haunching against the side of pipes after they are laid and tested for 150mm bore pipe complete all as specified and directed. |
| 9 | M & L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in bed to drain pipe including packing under and haunching against the side of pipes after they are laid and tested for 200 mm bore pipe complete all as specified and directed. |
| 10 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar including concrete bedding and haunching complete all as specified and directed for 300mm bore of pipe |
| 11 | M & L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in bed to drain pipe including packing under and haunching against the side of pipes after they are laid and tested for 300 mm bore pipe complete all as specified and directed. |
| 12 | S & F Reinforced concrete pipes, 300mm bore class NP2 with one collar per length of pipe, laid in trenches and jointed in CM 1:1 complete with collars complete all as specified and directed. |
| 13 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming channel (1/2 or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required with internal dia of Pipe 150mm |
| 14 | All as per Item No 13.00 above but 200 mm dia |
| 15 | Returning, filling in, ramming including, spreading, leveling, watering and well ramming in layers n.exc 25cm thick in soft/loose soil complete all as specified and directed. |
| 16 | Removing of surplus soil excavated materials to a distance exceeding 50 M but not exc 100M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 17 | M & L for providing precast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slab (for manholes and drains) including necessary form work set in CM 1:4 with and including demolition complete all as specified and directed.(Note:- Reinforcement shall be measured and paid separately) |
| 18 | M & L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 19 | S&F MS Framed workin small articles such as rungs, handles of man hole covers etc., grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 made to shape and placing in position complete all as specified and directed |
| 20 | Mechanically pumping out sewage water from sump well where required and as directed with taking precautionary measures including tools & plants as required and removing to a distances exc 50 metre but not exc 100M from the site complete (working in foul condition)all as specified directed by Engineer-in-Charge |
| 21 | Cleaning and desludging of existing septic tanks / sump well/ deep man holes of up to 3 metre deep including taking out sludge in any form alongwith all other foreign materials by mechanical equipment or manually or by way of any other suitable means including removal of sludge and other foreign materials out side the MD land by any means complete (working in foul condition) all as specified & directed. |
| 22 | Description all as per Item No 21.00 above but 3 to 6 mtr deep and ditto-- |
| 23 | Demolition of brick work built in cement mortar or cement lime mortarincluding all quoins, arches, pillars etc complete all as specified & directed. |
| 24 | Demolition of cement concrete in ground floor and paving n exc 15cm thickness (below or above the ground level) built in cement mortar complete all as specified and as directed. |
| 25 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, filling of mass concrete etc complete all as specified and as directed. |
| 26 | M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and as directed. |
| 27 | M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in path, floor and road cutting etc including finishd the suface even anf smooth complete all as specified and directed. |
| 28 | M & L for Brick work with sub-class `B\" bricks, straight or curved on plan exceeding 6 Mtr mean radius built in cement mortar 1:4 using old size bricks complete all as specified and directed. |
| 29 | M&L for providingPCC/RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coping,bands, plinth course, benching and other similar works including use and wast of necessary form work complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately) |
| 30 | M & L for rendering 15 mm thick on fair faces of walls of brick work or concrete surfaces in cement mortar 1:4 finished even and fair including taking down of existing plaster complete all as specified and as directed. |
| 31 | M & L for rendering 15 mm thick on fair faces of walls of brick work or concrete surfaces in cement mortar 1:4 finished even and fair complete all as specified and as directed. |
| 32 | M & L for rendering 15 mm thick on other than fair faces of walls of brick work or concrete surfaces in cement mortar 1:4 finished even and fair complete all as specified and as directed. |
| 33 | S&F in repair 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe and PVC connections 15mm size with PTMT nuts of length 450mm inlcuding taking out of old unserviceable connections etc, connecting up new and making good disturbed portion complete all as specified and directed by the Engineer-in-charge |
| 34 | S&F in repair vitreous china wash down water closet pan pedestal pattern including seat cover white excluding flushing cistern and flush pipe complete all as specified and directed. |
| 35 | S&F in repair vitreous China squatting pan (Orissa pattern), white, of size 580x440mm white, along with integral foot rests including flush pipe, lime concrete bedding inlcuding taking out of old WC pan, old lime concrete bedding, unserviceable connections etc connecting up new and making good disturbe portioncomplete all as specified and directed by the Engineer-in-charge |
| 36 | S&F in repair PVC (SWR) floor trap (Diameter of outlet 75mm)plain with grating including jointing to waste pipe and fixed in cement concrete 1:2: 4 (type B-1) mixed with and including liquid water proofing copound as per manufacturor instructions, inlcuding taking out of old unserviceable connections etc, connecting up new and making good disturbe portion complete all as specified and directed by the Engineer-in-charge |
| 37 | Dismantling of floor, hearth or wall tiles / terrazo(floor,dado) including cement mortar bedding (but not backing) complete all as specified and as directed. |
| 38 | M&L for Non-skid cermaic coloured floor tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 but n exc 0.11 sqm, in each , set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including15mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 39 | M&L for coloured glazed ceramictiles in vertical surface size 300x200x6-7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles over and including rendering 10mm thick rendering in CM 1:4 on brick wall complete all as specified and as directed. |
| 40 | M&L for area of 23 PARA, 29 PARA, BP linee, FMC, ODF, sheron line, MAP Accn,FMC,Met Calf Accn,Cdr House etc total area under Zone Á\" of AGE B/R-I area under AGE B/R-I (E) , cleaning of all blockage of any type of sewage line i.e branch sewer line, main sewer line etc, manholes of any section and depth, any situation by way of cleaning/desludging manholes by using any type of manually, mechanically or by way of any other suitable means including foreign materials as well as rodding of sewer lines and between successive from block manholes where required and ordered by Engineer-in-Charge and keeping the sewage line functional cleaning trap water closet, soil waste/vent pipe, gully traps upto final drop out let into septic tanks or central sewage system treatment in other adjoining Zone/Area of into sewage well (working in foul condition with taking precautionary measures) equipment as required or applicable all as specified and directed |
| 41 | S&F in repairPVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints laid in trenches or in floors etc including dismantling complete all as specified and directed . |
| 42 | S&F in repairPVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints fixed on wall etc including dismantling complete all as specified and directed . |
| 43 | S&F in repairPVC (SWR)pipes 75mm dia single socketed in any length with rubber ring joints laid in trenches or in floors etc including dismantling complete all as specified and directed . |
| 44 | S&F in repairPVC (SWR)pipes 75mm dia single socketed in any length with rubber ring joints fixed on wall etc including dismantling complete all as specified and directed . |
| 45 | S&F in repair PVC (SWR) bends any radius 110mm dia complete all as speified and directed |
| 46 | S&F in repair PVC (SWR) bends any radius 110mm dia with access doors complete all as speified and directed. |
| 47 | S&F in repair PVC (SWR) bends any radius 75mm dia complete all as speified and directed |
| 48 | S&F in repair PVC (SWR) bends any radius 75mm dia with access doors complete all as speified and directed. |
| 49 | S&F in repair PVC(SWR) \"T\" single (equal or unequal) 110 mm dia with access doors complete all as specified and directed |
| 50 | S&F in repair PVC(SWR) \"T\" single (equal or unequal) 75 mm dia with access doors complete all as specified and directed |
| 51 | S&F in repair 75 mm bore PVC (SWR) Vent Cowl complete all as specified and directed. |
| 52 | S&F in repair 110 mm bore PVC (SWR) Vent Cowl complete all as specified and directed. |
| 53 | S&F in repair PVC (SWR) gully trap of 125/110 mm dia set and jointing with solvent cement complete all as specified and directed. |
| 54 | S&F in repair cast iron spoil waste and vent pipe 75mm bore, in any length with or without ears with cement joints fixed to walls complete all as specified and directed. |
| 55 | S&F in repair cast iron spoil waste and vent pipe 100mm bore, in any length with or without ears with cement joints fixed to walls complete all as specified and directed. |
| 56 | S&F in repair cast iron bends 75mm bore diminisheing pieces or tapers complete all as specified and directed. |
| 57 | S&F in repair cast iron bends 100mm bore diminisheing pieces or tapers complete all as specified and directed. |
| 58 | S&F in repair cast iron branch pieces single/double ordinary or inverted (spoigot or socket type ) or with parallel branches 75mm bore complete all as specified and directed. |
| 59 | S&F in repair cast iron branch pieces single/double ordinary or inverted (spoigot or socket type ) or with parallel branches 100mm bore complete all as specified and directed. |
| 60 | Surface dressing n exc 15cm deep in soft / loose soil including removal of vegitation, shrubs , roots of trees to a distance n exc 100 metre from the site complete all as specified and directed. |