Procurement Of Medical Consumables Items For Use By The Cardiology Departments, Goa Medical College, Bambolim-Goa Procurement Of Medical Consumables Items For Use By The Cardiology Departments, Goa Medical College, Bambolim-Goa , Non-Invasive Cardiology Consumables , Injectable Cardiovascular Ultrasound Contrast Agent Comprised Of Lipid-Coated Echogenic Microbubbles Filled With Octafluoropropane Gas Or Equivalent Approved Agent ( Cost Comparison Will Be Based On Per Study Cost ) ; In Remarks - Please Detail The Dose Required Per Study Per The Instructions For Use , Disposable Electrodes For Patient Monitoring , Disposible Electrodes For Stress Testing - Please Quote Only Those That Are Specifically Designed For Stress Testing , Disposible Electrodes For Holter Monitoring - Please Quote Only Those That Are Specifically Designed For Holter Monitoring , Disposable Defibrillator Patches ( Anterior And Posterior ) For Use With Philips And Zoll Brand Defibrillators , Disposable Radiolucent Defibrillator Patches ( Anterior And Posterior ) For Use With Philips Defibrillators , Printer Paper Roll For Philips Mrx Defibrillator , Thermal Printing Paper For Sony Thermal Printer Used With Echocardiography Machines ( Model Up / D-897 ) , Ultrasound Jelly For Echocardiography 5 Litre Pack , Ecg Thermal Printing Paper For Use With Philips Pagewriter Tc20 Ecg Machine; Philips Make Only , Ecg Thermal Printing Paper For Use With Ge Mac 5500 Hd Ecg / Stress Testing Machine; Ge Make Only , Ecg Thermal Printing Paper For Use With Bpl Cardiart 6208 View Plus Ecgmachine; 80 Mm Width Roll , Filter For Hamiltonventilator Hma Anti-Bacterial Filter , Flow Sensor For Hamilton G5 Ventilator , General Surgical Items For Cardiac Cath Lab Use / Antiseptic Solutions / Cssd Related Items , Normal Saline 1 L Pouch Pack Suitable For Use With Pressure Infusor Bag , Normal Saline 0.5 L Pouch Pack Suitable For Use With Pressure Infusor Bag , Pressure Bag With Manometer For Iv Infusion / Pressure Infusor Bag , Silk Suture Sterilized And Packed With Cutting Needle 1.0 Silk Nw 5062 , Silk Suture Sterilized And Packed With Round Body Needle 1.0 Silk Nw 5063 , Surgical Skin Stapler With Stapler Cartridge For Pacemaker Pocket Closure , Staple Remover , Disposible Surgical Scalpel With Plastic Handle Number 11 , Surgical Disposible Scalpel Blade Only Number 11 , Surgical Disposible Scalpel Blade Only Number 15 , Iodine Impregnated Antimicrobial Transparent Incise Drape 13 X 13 , Film Transparent Dressing With Non-Adherent Pad 3 1 / 2 Inches X 6 Inches ( 9 X 15 Cm ) , Packing Material For Cath Lab Use 5 Cm Width X 200 Metres Roll , Packing Material For Cath Lab Use 7.5 Cm Width X 200 Metres Roll , Packing Material For Cath Lab Use 10 Cm Width X 200 Metres Roll , Packing Material For Cath Lab Use 15 Cm Width X 200 Metres Roll , Packing Material For Cath Lab Use 20 Cm Width X 200 Metres Roll , Packing Material For Cath Lab Use 25 Cm Width X 200 Metres Roll , Packing Material For Cath Lab Use 30 Cm Width X 200 Metres Roll , Ethylene Oxide ( Eto ) Gas Cartridge , Labelling Instrument For Packed Items For Cath Lab , Printer Ribbon For Use In Labelling Instrument , Label Roll For Use With Instrument Quoted For In Labelling Instrument With Built In Eto Exposure Indicator , Label Roll For Use With Instrument Quoted For In Labelling Instrument With Built In Steam Exposure Indicator , Biological Indicator For Use In Eto Sterilizer , Biological Indicator For Use With Autoclave Sterilizer , Incubator For Use With Biological Indicators Quoted Above , Sterile Plastic Impermeable To Fluids Sheet For Use On Instrument Table 1 Meter X 1.25 Meter , Bacillocid Liquid For Fumigation , Bacillocid Spray For Surface Cleaning , Chlorhexidine Gluconate 2% In Ethanol For Skin Disinfection Prior To Surgery / Cardiac Catheterization , 10% Betadine Solution , 7.5% Betadine Scrub Solution , Cidenzyme Solution , Elastic Adhesive Bandage , 4 X 4 Sterile Gauze Pack With Radio-Opaque Marker In Each Gauze Piece - Pack Of 20 , 4 X 4 Sterile Gauze Pack Without Radio-Opaque Marker- Pack Of 20 , Sterile, Disposable Catheterization Drape For Covering Patients During Catheterization / Intervenion Procedures. Size 220- 230 X 330-350 Cm, With Two 10-12Cm Adhesive Fenestrations At The Site Of Femoral Artery Puncture, Having Absorbent As Well As Laminated Reinforcement. , Disposable Sterile Surgical Gowns For Ot Use With Impermeable / Absorbent Material To Fluids And Elastic Arm Cuffs , Sterile Plastic Cover For Philips Fd10 Cath Lab Detector Housing With Circumference Of 50 , Sterile Plastic Cover For Philips Fd10 Cath Lab Tube Housing With Circumference More Than 50 , Sterile Plastic Cover For Philips Cath Lab Radiation Shield ( Ceiling Mounted ) With Size 36 X 48 , Disposible Surgical Face Mask , Disposible Surgical Head Cap Tie Down Type , Disposible Surgical Head Cap Bouffant Type , Disposable Sterile Surgical Gloves Powderless With Sizes From 6.0 To 8.0 , Sterile Plastic Sleeve Cover For Ultrasound Probe Minimum Length Of 1.5 Metre Packed With Sterile Sealed Single Patient Use Ultrasound Jelly , Sterile Plastic Sleeve Cover For Ultrasound Probe Minimum Length Of 1.5 Metre , General Cath Lab Items , Disposable Pressure Transducer For Use With Philips Invasive Bp Montiror Ex. Mp20 - Edwards Type; Required To Supply One Pressure Transducer Cable With Every 25 Transducers , High Range Act Cartridge For Use In Medtronic Act Plus Machine , Sheaths Including Guide Sheaths / Other Specialized Sheaths And Access Needles Including Transeptal Needles And Other Access Materials / Vascular Hemostasis / Closure Devices , Pediatric Introducer Sheath ( 10-12 Cm ) With Haemostatic Valve And Side Arm In A Kit Containing Puncture Needle And Guide Wire; 4F With 0.020-.035 Short / Mini Wire , Pediatric Introducer Sheath ( 10-12 Cm ) With Haemostatic Valve And Side Arm In A Kit Containing Puncture Needle And Guide Wire; 5F With 0.020-.035 Short / Mini Wire , Adult Introducer Sheath ( 10-12 Cm ) With Haemostatic Valve And Side Arm In A Kit Containing Puncture Needle And Guide Wire; 5F With 0.035-0.038 Short / Mini Wire , Adult Introducer Sheath ( 10-12 Cm ) With Haemostatic Valve And Side Arm In A Kit Containing Puncture Needle And Guide Wire; 6F With 0.035-0.038 Short / Mini Wire , Adult Introducer Sheath ( 10-12 Cm ) With Haemostatic Valve And Side Arm In A Kit Containing Puncture Needle And Guide Wire; 7F With 0.035-0.038 Short / Mini Wire , Adult Introducer Sheath ( 10-12 Cm ) With Haemostatic Valve And Side Arm In A Kit Containing Puncture Needle And Guide Wire; 8F With 0.035-0.038 Short / Mini Wire , Adult Introducer Sheath ( 10-12 Cm ) With Haemostatic Valve In A Kit Containing Puncture Needle And Guide Wire; 9F With 0.035-.038 Short / Mini Wire , Adult Introducer Sheath ( 10-12 Cm ) With Haemostatic Valve In A Kit Containing Puncture Needle And Guide Wire; 10F With 0.035-.038 Short / Mini Wire , Adult Introducer Sheath ( 10-12 Cm ) With Haemostatic Valve In A Kit Containing Puncture Needle And Guide Wire; 12F With 0.035-.038 Short / Mini Wire , Adult Introducer Sheath ( 10-12 Cm ) With Haemostatic Valve In A Kit Containing Puncture Needle And Guide Wire; 14F With 0.035-.038 Short / Mini Wire , Adult Introducer Sheath ( 25 Cm ) With Haemostatic Valve And Side Arm In A Kit Containing Puncture Needle And Guide Wire; 6F With 0.035-0.038 Short / Mini Wire , Adult Introducer Sheath ( 25 Cm ) With Haemostatic Valve And Side Arm In A Kit Containing Puncture Needle And Guide Wire; 7F With 0.035-0.038 Short / Mini Wire , Adult Introducer Sheath ( 25 Cm ) With Haemostatic Valve And Side Arm In A Kit Containing Puncture Needle And Guide Wire; 8F With 0.035-0.038 Short / Mini Wire , Adult Introducer Braided Kink Resistant Sheath ( 45 Cm ) With Haemostatic Valve And Side Arm In A Kit Containing Puncture Needle And Guide Wire; 6F With 0.035-0.038 Short / Mini Wire , Adult Introducer Sheath ( 45 Cm ) With Haemostatic Valve And Side Arm In A Kit Containing Puncture Needle And Guide Wire; 6F With 0.035-0.038 Short / Mini Wire , Adult Introducer Sheath ( 45 Cm ) With Haemostatic Valve And Side Arm In A Kit Containing Puncture Needle And Guide Wire; 7F With 0.035-0.038 Short / Mini Wire , Adult Introducer Sheath ( 45 Cm ) With Haemostatic Valve And Side Arm In A Kit Containing Puncture Needle And Guide Wire; 8F With 0.035-0.038 Short / Mini Wire , Radial Artery Cannulation Kit Comprising Of Arterial Sheath With Hydrophilic Coating, Short Puncture Needle 20 / 21 G, Compatible Guide Wire Of 0.018 / 0.0.21 / 0.025 And 45-50 Cm Long Straight Tip. 5F; To Contain Puncture Needle / Cannula , Radial Artery Cannulation Kit Comprising Of Arterial Sheath With Hydrophilic Coating, Short Puncture Needle 20 / 21 G, Compatible Guide Wire Of 0.018 / 0.0.21 / 0.025 And 45-50 Cm Long Straight Tip. 6F; To Contain Puncture Needle / Cannula , Radial Artery Cannulation Kit Comprising Of Arterial Sheath With Hydrophilic Coating, Short Puncture Needle 20 / 21 G, Compatible Guide Wire Of 0.018 / 0.0.21 / 0.025 And 45-50 Cm Long Straight Tip. 5F Entry Profile But Capable Of Accomodating 6F Catheters; To Contain Puncture Needle / Cannula Such As Terumo Slender 5F Sheath , Radial Artery Cannulation Kit Comprising Of Arterial Sheath With Hydrophilic Coating, Short Puncture Needle 20 / 21 G, Compatible Guide Wire Of 0.018 / 0.0.21 / 0.025 And 45-50 Cm Long Straight Tip. 6F Entry Profile But Capable Of Accomodating 7F Catheters; To Contain Puncture Needle / Cannula Such As Terumo Slender 5F Sheath , Radial Artery Cannulation Kit Comprising Of Arterial Sheath With Hydrophilic Coating, Short Puncture Needle 20 / 21 G, Compatible Guide Wire Of 0.018 / 0.0.21 / 0.025 And 45-50 Cm Long Straight Tip. 7F; To Contain Puncture Needle / Cannula , Single Lumen Balloon Wedge Pressure Catheter ( Swan Ganz ) With End Hole Beyond The Balloon At The Distal Tip. Size 5F , Single Lumen Balloon Wedge Pressure Catheter ( Swan Ganz ) With End Hole Beyond The Balloon At The Distal Tip. Size 6F , Trans-Septal Puncture Needle, Adult, Curved, For Atrial Septal Puncture. , Trans-Septal Puncture Needle, Pediatric, Curved, For Atrial Septal Puncture. , Mullins Sheath With Hemostatic Valve 6F ( Will Be Selected Of Same Company Who Is L1 For Brochenbrough Trans-Septal Needle ) , Mullins Sheath With Hemostatic Valve 7F ( Will Be Selected Of Same Company Who Is L1 For Brochenbrough Trans-Septal Needle ) , Mullins Sheath With Hemostatic Valve 8F ( Will Be Selected Of Same Company Who Is L1 For Brochenbrough Trans-Septal Needle ) , Mullins Sheath With Hemostatic Valve 6F For Pediatric Use / Short Length ( Will Be Selected Of Same Company Who Is L1 For Brochenbrough Needle ) , Mullins Sheath With Hemostatic Valve 9-12F ( Will Be Selected Of Same Company Who Is L1 For Brochenbrough Needle ) , Long Guiding Sheath, 40-45 Cm Long. Flexor / Destination Tuohy Borst Side Arm. 5F , Long Guiding Sheath, 40-45 Cm Long. Flexor / Destination Tuohy Borst Side Arm. 6F , Long Guiding Sheath, 40-45 Cm Long. Flexor / Destination Tuohy Borst Side Arm. 7F , Long Guiding Sheath, 40-45 Cm Long. Flexor / Destination Tuohy Borst Side Arm. 8F , Long Guiding Sheath, 55-65 Cm Long. Flexor / Destination Tuohy Borst Side Arm. 5F , Long Guiding Sheath, 55-65 Cm Long. Flexor / Destination Tuohy Borst Side Arm. 6F , Long Guiding Sheath, 55-65 Cm Long. Flexor / Destination Tuohy Borst Side Arm. 7F , Long Guiding Sheath, 55-65 Cm Long. Flexor / Destination Tuohy Borst Side Arm. 8F , Long Guiding Sheath, 70-90 Cm Long. Flexor / Destination Tuohy Borst Side Arm. 5F , Long Guiding Sheath, 70-90 Cm Long. Flexor / Destination Tuohy Borst Side Arm. 6F , Long Guiding Sheath, 70-90 Cm Long. Flexor / Destination Tuohy Borst Side Arm. 7F , Long Guiding Sheath, 70-90 Cm Long. Flexor / Destination Tuohy Borst Side Arm. 8F , Long Guiding Sheath, 40-45 Cm Long. Flexor / Destination Cross Cut Or Check-Flo Valve. 5F , Long Guiding Sheath, 40-45 Cm Long. Flexor / Destination Cross Cut Or Check-Flo Valve. 6F , Long Guiding Sheath, 40-45 Cm Long. Flexor / Destination Cross Cut Or Check-Flo Valve. 7F , Long Guiding Sheath, 40-45 Cm Long. Flexor / Destination Cross Cut Or Check-Flo Valve. 8F , Long Guiding Sheath, 55-65 Cm Long. Flexor / Destination Cross Cut Or Check-Flo Valve. 5F , Long Guiding Sheath, 55-65 Cm Long. Flexor / Destination Cross Cut Or Check-Flo Valve. 6F , Long Guiding Sheath, 55-65 Cm Long. Flexor / Destination Cross Cut Or Check-Flo Valve. 7F , Long Guiding Sheath, 55-65 Cm Long. Flexor / Destination Cross Cut Or Check-Flo Valve. 8F , Long Guiding Sheath, 70-90 Cm Long. Flexor / Destination Cross Cut Or Check-Flo Valve. 5F , Long Guiding Sheath, 70-90 Cm Long. Flexor / Destination Cross Cut Or Check-Flo Valve. 6F , Long Guiding Sheath, 70-90 Cm Long. Flexor / Destination Cross Cut Or Check-Flo Valve. 7F , Long Guiding Sheath, 70-90 Cm Long. Flexor / Destination Cross Cut Or Check-Flo Valve. 8F , Destination Type Sheath 45 Cm Length With Rdc Curve / Ima Curve / Multipurpose Curve - 6F , Destination Type Sheath 45 Cm Length With Rdc Curve / Ima Curve / Multipurpose Curve - 7F , Destination Type Sheath 45 Cm Length With Rdc Curve / Ima Curve / Multipurpose Curve - 8F , Long Sheaths Ofwith Side Arms ( Balken Type ) 5.5F 40 Cm For Contralateral Access , Long Sheaths Ofwith Side Arms ( Balken Type ) 6F 40-45 Cm For Contralateral Access , Long Sheaths Ofwith Side Arms ( Balken Type ) 6F 55 Cm For Contralateral Access , Long Sheaths Ofwith Side Arms ( Balken Type ) 7F 40-45 Cm For Contralateral Access , Long Sheaths Ofwith Side Arms ( Balken Type ) 7F 55 Cm , Guiding Sheaths For Vascular Intervention; Should Be Flexible And Kink Resistant, With Coil Reinforced Tubing And Ptfe Inner Lining And Atraumatic Tip; 5F With Various Lengths Starting Up From 45 Cm , Guiding Sheaths For Vascular Intervention; Should Be Flexible And Kink Resistant, With Coil Reinforced Tubing And Ptfe Inner Lining And Atraumatic Tip; 6F With Various Lengths Starting Up From 45 Cm , Guiding Sheaths For Vascular Intervention; Should Be Flexible And Kink Resistant, With Coil Reinforced Tubing And Ptfe Inner Lining And Atraumatic Tip; 7F With Various Lengths Starting Up From 45 Cm , Rtps Sheath 10F / 12F Sheath With 0.038 Wire Lumen; 38.5 Cm , Rtps Sheath 10F / 12F Sheath With 0.038 Wire Lumen; 90 Cm , Steerable Introducer Able To Be Steered Between 0-180 Degrees With Diameters Between 5-14 F And Lengths Between 550-900 Mm With Anti-Kinking Design And Radiopaque Band At Distal Tip. , 20 G Angio Needle For Vascular Puncture With Short Bevel Tip And Short Length Suitable For Radial Artery Puncture , 18 G Angio Needle For Vascular Puncture Suitable For Femoral Vessel Puncture , Micro-Puncture Set For Arterial / Av Fistula Ascess - 3-5F Sheath; 0.018 Wire With Atraumatic Tip; 21G X 4 Cm Needle , Micro-Puncture Set For Ptbd Access -3- 5F Sheath; 0.018 Wire With Atraumatic Tip; 21G X 7 Cm Needle , Trocar Needle 18G15-20Cm Length , Cheeba Needle 18-23G And Minimum Of 15Cm Length , 21 G Biliary Ascess Set With 0.018 Guidewire With 22G 15 Cm Needle Length With 7 F Sheath Of 18 Cm Length Ex. Neff Set , Pedal Arterial Access - 4F Sheath; 0.018 / 0.014 Wire With Atraumatic Tip; 21G X 4 Cm Needle , Pedal Arterial Access - 5F Sheath; 0.018 / 0.014 Wire With Atraumatic Tip; 21G X 4 Cm Needle , Jelco 20G X 32 Mm Radiopaque ( Without Wings ) , Leader Cath- For Arterial Puncture For Pediatric Patients , Micro-Puncture Set For Arterial Access -3-4F Sheath; 0.018 Wire With Atraumatic Tip; 21G X 4 Cm Needle , Femoral Percutaneous Closure Device ( Collagen Sponge Mediated Closure ) . , Suture Mediated Closure Device With Single Suture For Arterial Closure , Radial Closure Device Comprising Of Two Pneumatically Inflated Balloons ( Pneumatically Inflated With A Syringe ) With Anatomic Softwrist Support Pad With Usfda Approval , Radial Closure Device Comprising Of Dual Compression Pads ( Pneumatically Inflated With A Syringe ) With Anatomic Softwrist Support Pad. , Manifolds, Pressure Lines; Iv Sets; Ptca Accessories; Tubings; Syringes. , Manifold - Two Ports With Knobs To Turn Right When Open , Pressure Line: 150 And 200 Cm Long, 4-6 Mm Diameter, Compatible With Manifold And Three Way Ports , High Pressure Injector Line To Withstand Pressure Up To 1200 Psi, 100-150 Cm Length With Luer Lock Male Port And Rotator , Iv Set With Distal Luer Lock Connection; Non Latex; With Drip Chamber And Flow Control Mechanism , Luer Lock Syringe 10 Ml , Slip Tip / Non-Luer Lock Syringe 10 Ml , Syringe 2 Ml Luer Lock , Syringe 2 Ml Non Luer Lock ( Slip Tip ) , Syringe 5 Ml Luer Lock , Syringe 5 Ml Non Luer Lock ( Slip Tip ) , Luer Lock Syringe 20 Ml , Luer Lock Syringe 50 Ml , 150 Cc Disposable Plastic Syringe For Angiography Injector Of Angiomat Illumena Injector , Inflation Device : Should Register Pressures From Vac To 30 Atmospheres ( Vac To 441 Psi ) With A Threaded Plunger And Locking Switch Which Allow For The Generation And Sustaining Of Pressure And Three Way Stop Cock For Use During Preparation Of The Device And In Conjuction With Interventional Devices. The Pressure Displayglows In Dark For Easy Visibility. Ergonomic And Easy To Use. , Bleedback Control Valve With Twin Seals: Bleed-Back Seal And Clamp Seal - Permits High Pressure Injections Up To 400 Psi. Easy Grip Push-Pull Knob For Single Operator Use And Complete Hemostasis. , The Ptcapack Of Accessories Should Be A Single Sku Kit Containing A 30 Atm Capacity Inflation Device, A Bleedback Control Valve With Twin Seals ( Bleed Back And Clamp ) With Easy Grip Push Pull Knob For Complete Hemostasis And Gw Assessories-Introducer And Torquer , Inflation Device: With Manometer Of 0-26 Or Greater Atmosphere And Luminescent Dial Face. Easy To Operate With Ergonomic Design. High Strength Syringe To Maintain High Pressure Setting Without Pressure Loss And Immediate Pressure Release; In A Kit Containing Y Connector Spring Type; With Ptca Wire Insertion Needle And Torque Device , Ptca Wire Insertion Needle, 0.014 Wire Torque Device, Y Conector ( Spring Type ) And Separate 10 Cm Tubing With Three Way Connector , Ptca Wire Insertion Needle, 0.014 Wire Torque Device, Y Conector ( Screw Type ) And Separate 10 Cm Tubing With Three Way Connector , Ptca Insertion Needle And Torque Device Accepting 0.014 And 0.018 Guide Wires. , Y-Connector For Ptca: Hemostatic Valve With Screw Type Y-Connector For Ptca And Without Formation Of Micro / Macro Air Bubbles Inside It During The Precedure. , Y-Connector For Ptca: Hemostatic Valve With Spring Type Y-Connector For Ptca And Without Formation Of Micro / Macro Air Bubbles Inside It During The Precedure. , Y-Connector For Ptca: Hemostatic Valve With Push / Pull Type Y-Connector For Ptca And Without Formation Of Micro / Macro Air Bubbles Inside It During The Precedure. , Y-Connector For Ptca: Two Large Bore Hemostatic Valve With Push Pull / Scewin Type Y-Connector For Ptca And Without Formation Of Micro / Macro Air Bubbles Inside It During The Precedure. , 10 Cm Length Connection Tubing With Integrated 3-Way Stopcock , Y Connector With Double Seal - One With Push Pull And Other With Screw Type With Ability To Lock Push And Pull Mechanism And With 10F Bore Ex. Okay Ii , Iabp Catheters, Ffr Wires, Ivus Related, Rotablator Related; Oct Related; Ivl Related; Elca Related , Intra-Aortic Balloon Pump Catheter Compatible With Datascope Cs 100 Machine , Pressure Wire For Ffr And Rfr Measurement Compatible With St. Jude Ffr Measurement Console - Wireless Type , Ivus Imaging Catheter Compatible With Boston Scientific Ivus Imaging Machine For Coronary Imaging With Hd Resolution , Ivus Imaging Catheter Compatible With Boston Scientific Ivus Imaging Machine For Coronary Imaging With Standard Resolution , Ivus Imaging Catheter Compatible With Boston Scientific Ivus Imaging Machine For Peripheral Arterial Imaging , Ivus Imaging Sled For Catheter Specified Above , Rota Burr For Rotational Coronary Atherectomy, 1.25-2.0Mm - Burr Only , Rota Burr For Rotational Coronary Atherectomy, 1.25-2.0Mm - Burr With Advancer , Advancer For Rotational Atherectomy Compatible With Boston Scientific Atherectomy Burr , Coronary Wire Designed For Use With Burr Of Rotational Atherectomy With Standard Support , Coronary Wire Designed For Use With Burr Of Rotational Atherectomy With Extra Support , Oct Imaging Catheter Compatible With Current Oct Console On The Market , Intra-Vascular Lithotripsy Catheter For Coronary Use Including Cost Of Ivl Console To Be Used During The Procedure ( Not Purchase Of The Console ) , Intra-Vascular Lithotripsy Catheter For Peripheral Arterial ( Iliac / Sfa ) Use Including Cost Of Ivl Console To Be Used During The Procedure ( Not Purchase Of The Console ) , Intra-Vascular Lithotripsy Catheter For Peripheral Arterial ( Infra-Popliteal ) Use Including Cost Of Ivl Console To Be Used During The Procedure ( Not Purchase Of The Console ) , Laser Catheter For Elca For Coronary Use Of Various Sizes; Company To Make Available The Required Excimer Laser System For The Case , Diagnostic Catheters , Coronary Angiography 4F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Judkins Left , Coronary Angiography 4F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Judkins Right , Coronary Angiography 4F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Multipurpose , Coronary Angiography 4F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Pigtail , Coronary Angiography 5F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0, 6.0 As Required At Time Of Order- Judkins Left , Coronary Angiography 5F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Judkins Right , Coronary Angiography 5F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Multipurpose A1 And A2 , Coronary Angiography 5F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Left Coronary Bypass , Coronary Angiography 5F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Right Coronary Bypass , Coronary Angiography 5F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order-Amplatz Left , Coronary Angiography 5F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order-Amplatz Right , Coronary Angiography 5F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- No Torque Right / Williams Right / 3D Right , Coronary Angiography 5F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Ima Type , Coronary Angiography 5F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Pigtail , Coronary Angiography 6F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Judkins Left , Coronary Angiography 6F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Judkins Right , Coronary Angiography 6F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Multipurpose A1 And A2 , Coronary Angiography 6F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Left Coronary Bypass , Coronary Angiography 6F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Right Coronary Bypass , Coronary Angiography 6F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order-Amplatz Left , Coronary Angiography 6F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order-Amplatz Right , Coronary Angiography 6F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- No Torque Right / Williams Right / 3D Right , Coronary Angiography 6F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Ima Type , Coronary Angiography 6F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Pigtail , Coronary Angiography 6F Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves ( Wherever Applicable ) Of1, 2, 3.0, 3.5, 4.0, 5.0 As Required At Time Of Order- Angled Pigtail , Radial Diagnostic Coronary Catheter With Tiger Curve And Side Holes -5F , Radial Diagnostic Coronary Catheter With Tiger Curve And Side Holes - 6F , Coronary Angiography 5F Diagnostic Catheters 100 Cm Or Longer For Radial Approach And Various Curves ( Wherever Applicable ) Of 4.0, 4.5 As Required At Time Of Order; Catheter Should Be Double Braided For Superior Torque Control And Should Have Coating To Minimize Vessel Spasm , Coronary Angiography 6F Diagnostic Catheters 100 Cm Or Longer For Radial Approach And Various Curves ( Wherever Applicable ) Of 4.0, 4.5 As Required At Time Of Order; Catheter Should Be Double Braided For Superior Torque Control And Should Have Coating To Minimize Vessel Spasm , Marker Pigtail Catheter 5F / 6F;=>110Cm Long , Cobra Catheter With Hydrophilic Coating And Soft Tip C1 - 4F , Cobra Catheter With Hydrophilic Coating And Soft Tip C2 - 4F , Cobra Catheter With Hydrophilic Coating And Soft Tip C1 - 5F , Cobra Catheter With Hydrophilic Coating And Soft Tip C2 - 5F , Head Hunter Catheter With Hydrophilic Coating And Soft Tip - 5F And H1 , Head Hunter Catheter With Hydrophilic Coating And Soft Tip - 5F And H2 , Jb2 Catheter Wit Hydrophilic Coating And Soft Tip 5F , Simmons Catheter With Hydrophilic Coating And Soft Tip 5F With Size 0.5 , Simmons Catheter With Hydrophilic Coating And Soft Tip 5F With Size 0.75 , Simmons Catheter With Hydrophilic Coating And Soft Tip 5F With Size 1.0 , Simmons Catheter With Hydrophilic Coating And Soft Tip 5F With Size 2.0 , Vtk ( Vitek ) Catheter For Carotid Angiography, 125 Cm Long, 5F , Balloon Flotation Angiographic Catheter ( Berman Type ) With Side Holes And End Hole At The Tip Of The Catheter For Wire Access, 4F / 5F / 6F , Cournand Catheter 4F / 5F , Nih Catheter 4F / 5F , Goodale-Lubin Catheter , 5F Rc-1 65 Cm Catheter With Hydrophilic Coating And Soft Non-Becon Tipcompatible With 0.38 Guidewire , 5F Renal Double Curve Catheter With Hydrophilic Coating And Soft Non-Becon Tipcompatible With 0.38 Guidewire , 5F Picard 100 Cm Catheter With Hydrophilic Coating And Soft Non-Becon Tipcompatible With 0.38 Guidewire , 5F Multipurpose ( Mpa ) Catheter 65 Cm Catheter With Hydrophilic Coating And Soft Non-Becon Tipcompatible With 0.38 Guidewire , 5F Robertson Uterine Catheter 110 Cm Catheter With Hydrophilic Coating And Soft Non-Becon Tipcompatible With 0.38 Guidewire , Pigtail Catheter For Neonatal And Pediatric Use, Short Length And 4F , Pigtail Catheter For Neonatal And Pediatric Use, Short Length And 5F , Infusion Catheter For Peripheral Thrombolysis With Varied Infusion Lengths , Glide-Catheter With Hydrophilic Polymer Coating Over The Catheter Shaft For Peripheral Interventions / Angiography - 4F With Straight Tip , Glide-Catheter With Hydrophilic Polymer Coating Over The Catheter Shaft For Peripheral Interventions / Angiography - 4F With Angled Tip , Glide-Catheter With Hydrophilic Polymer Coating Over The Catheter Shaft For Peripheral Interventions / Angiography - 5F With Straight Tip , Glide-Catheter With Hydrophilic Polymer Coating Over The Catheter Shaft For Peripheral Interventions / Angiography - 5F With Angled Tip , Glide-Catheter With Hydrophilic Polymer Coating Over The Catheter Shaft For Peripheral Interventions / Angiography - 6F With Straight Tip , Glide-Catheter With Hydrophilic Polymer Coating Over The Catheter Shaft For Peripheral Interventions / Angiography - 6F With Angled Tip , Multi Track Angiography Catheter For Angiography While Catheter Is Over The Wire By Short Monorail Part At Distal Tip, Size 5-6 F. , Angiographic Guide Wires / Coronary And Peripheral Angioplasty Wires , Angiographic Guide Wire 0.035, Ptfe Coated - Normal Length ( 150-180 Cm ) J Tip. The J Tip Can Be Fingertip Modified Into Any Shape , Angiographic Guide Wire 0.035, Ptfe Coated - Extra-Length ( 250-260 Cm Or Longer ) J Tip. The J Tip Can Be Fingertip Modified Into Any Shape , Angiographic Guide Wire 0.035, Ptfe Coated - Extra Length ( 250-260 Cm ) With Straight Tip , Angiographic Guide Wire 0.035, Ptfe Coated - Extra Length ( Minimum 260 Cm ) With J Tip And Preformed Large Curve For Left Ventricular Placement In Balloon Valvuloplasty E.G. Apex Wire , Angiographic Guide Wire Ptfe Coated, J Tip. Diameter: 0.018 250-260 Cm , Angiographic Guide Wire Ptfe Coated, Straight Tip. Diameter: 0.018 250-260 Cm , Angiographic Guide Wire Ptfe Coated, J Tip. Diameter: 0.025 250-260 Cm , Angiographic Guide Wire Ptfe Coated, Straight Tip. Diameter: 0.025 250-260 Cm , Angiographic Guide Wire Ptfe Coated, J Tip. Diameter: 0.032 150-260 Cm , Angiographic Guide Wire Ptfe Coated, Straight Tip. Diameter: 0.032 150-260 Cm , Hydrophilic Coated Glide Wire, Angled / Straight Tipwith Hydrophilic Polymer Size In Inches 0.018 To 0.038 Length 150-160 Cm. Usfda And Jpmda Approved , Hydrophilic Coated Glide Wire, Angled / Straight Tipwith Hydrophilic Polymer Size In Inches 0.018 To 0.038 Length 260 Cm. Usfda And Jpmda Approved , Hydrophilic Coated Glide Wire, Angled / Straight Tipwith Hydrophilic Polymer Size In Inches 0.018 To 0.038 Length 150-160 Cm. , Hydrophilic Coated Glide Wire, Angled / Straight Tipwith Hydrophilic Polymer Size In Inches 0.018 To 0.038 Length 260 Cm. , Hydrophilic Coated 0.035 Spring Coil Guide Wire With Actone , Double Coil Structure Distal 15 Cm Silicone Coating , Rest 65 Cm Hydrophilic Coatinglength150 Cm -180 Cmangled & J Shape , Hydrophilic Coated 0.035 Spring Coil Guide Wire With Actone , Double Coil Structure Distal 15 Cm Silicone Coating , Rest 65 Cm Hydrophilic Coatinglength 200 Cm - 300 Cm Angled & J Shape , Hydrophilic Coated 0.035 Nitinol Guide Wire With Blue Hydrophilic Coating And Lengths Of 260 Cm , Amplatzer Super Stiff Guide Wire, Standard Length Of 150 Cm Of 0.035 Diameter. , Amplatzer Super Stiff Guide Wire, Long Length Of 260 Cm - 300 Cm Of 0.035 Diameter. , Amplatzersuper Stiff Guide Wire, Long Length Of 260 Cm - 300 Cm Of 0.035 Diameter Cook Make , Amplatzerultra Stiff Guide Wire, Standard Length Of 150Cm Of 0.035 Diameter Cook Make , Amplatzerultra Stiff Guide Wire, Long Length Of 260 Cm - 300 Cm Of 0.035 Diameter Cook Make , Supra-Core Guide Wire, 0.035 And 0.038 Size And Extra-Length Of 260 Cm Or More. , Amplatzer Super Stiff Guide Wire With 3Cm J Curve ; Long Length Of 260 Cm - 300 Cm Of 0.035 Diameter Boston Scientific Make , Amplatzer Super Stiff Guide Wire With 1Cm J Curve Long Length Of 260 Cm - 300 Cm Of 0.035 Diameter Boston Scientific Make , Noodle Wire, 0.035 Diameter, 300 Cm Long For A-V Loop Formation. , Sion Tecc Technology , Actone Braiding , 1.5 Cm Distal Silicone Coating , 18.5 Cm Hydrophilic Coating , 20 Cm Spring Coil , Tip Diameter 0.014 Inch , Tip Load 0.5 Gm , Sion Tecc Technology , Actone Braiding , 28 Cm Hydrophilic Coating , 28 Cm Spring Coil , Tip Diameter 0.014 Inchtip Load 0.7 Gm , Sion Tecc Technology , Actone Braiding , 17 Cm Polymer Jacket17 Cm Slip Coat Coating , Radiopaque Length 16 Cm28 Cm Spring Coil , Tapered Tip 0.010 Inchtip Load 0.6 Gm , Sion Tecc Technology , Actone Braiding , 17 Cm Polymer Jacket17 Cm Slip Coat Coating , Radiopaque Length 16 Cm28 Cm Spring Coil , Tapered Tip 0.010 Inch , Tip Load 1.0 Gm , Sion Tecc Technology , Actone Braiding , 17 Cm Polymer Jacket17 Cm Slip Coat Coating , Radiopaque Length 16 Cm28 Cm Spring Coil , Tip Load 0.8 Gm, Usable Length 190 Cm , Sion Tecc Technology , Actone Braiding , Spring Coil Length 15 Cm, Radiopaque Length 15 Cm, Tapered Tip 0.010 Inch Gaia 1Sttip Load 1.7 Gm Tapered Tip 0.011 Inch Gaia 2Nd Tip Load 3.5 Gm , Tapered Tip 0.012 Inch Gaia 3Rd Tip Load 4.5 Gm , All Are Mini - Pre Shaped 1Mm 45 Degree Angle , Micro Cone Tip Used For Cto Cases , Sion Tecc Technology , Actone Braiding , Tip Load 0.5 Gm , 1.5 Cm Silicone Coating , 40 Cm Hydrophilic Coating , 8.5 Cm Spring Coil Length Tip Diameter 0.014 Inch , Core To Tip , Tip Load 0.8 Gm , Tip Radiopacity 16 Cm , Polymer Jacket Length 16 Cm , Tip Diameter 0.009 Inch , Slip Coat Over The Polymer Jacket , Single Core To Tip , Tip Load 0.8 Gm , Tip Radiopacity 3 Cm , Spring Coil Length 11 Cm , Tip Diameter 0.014 Inch , Hydrophilic Coating Over Spring Coil , Singl Core , Core To Tip , Tip Load 0.8 Gm , Tip Radiopacity 3 Cm , Tip Diameter 0.014 Inch, Slip Coat Over The Spring Coil , Single Core Core To Tip 150 Cm & 165 Cm , Single Core , Core To Tip , Tip Load 3Gm , Tip Radiopacity 3 Cm , Tip Diameter 0.014 Inch, Tip Radiopacity 11 Cm , Slip Coat Over The Spring Coil Used For Cto Lesion , Single Core Core To Tip , Tip Load 9 Gm Tapered 0.090 Inch For Cto Lesionwith 20 Cm Radio-Opaque Tip With Hydrophilic Coating , Single Core Core To Tip , Tip Load 12 Gm Tapered 0.090 Inch For Cto Lesionwith 20 Cm Radio-Opaque Tip With Hydrophilic Coating , Single Core Core To Tip , Tip Load 20 Gm Tapered 0.090 Inch For Cto Lesionwith 17 Cm Radio-Opaque Tip With Hydrophilic Coating , Single Core Core To Tip , Tip Load 3 Gm, Radiopacity 3 Cm , Guide Wire Length 330 Cm , Slip Coat Over The Spring Coil , Coronary Angioplasty Wire Suitable For Septal Collateral Channel Crossing With 0.3 Gm Tip-Load , Single Core Core To Tip , Tip Load 0.7 Gm, Radiopacity 4 Cm , Spring Coil Length 4 Cm , Siliconecoat Over The Spring Coil, Extra Support Wire , Hydrophilic Nitinol Wire With Soft Tip Load Of <1Gm And Shaping Ribbon Design. 3 Cm Radiopaque Tip , Hydrophilic, Fully Polymer Covered Wire Family With Transitionless Grind From Core-To-Tip And Multiple Support Variants For Providing Moderate Spport And Extra Support. Available In St Tip And Preshaped J Tip Design. 3 Cm Radiopaque Tip. , Extra Support Steel Guidewire With Full Polymer Cover Hydrophilic Coating, Core To Tip And Distal Gold Marker At 4.5Cm, Radiopaque Tip Length Of 3Cm, Tiploads1.5Gm, Available In St Tip And J Tip , Lesion Specific Special Technology Cto Wire With Polymer Sleeve Cover, Hydrophilic Coating, Core To Tip And Distal Gold Marker At 4.5Cm. Radiopaque Tip Length Of 3Cm, Tipload Between 2.7Gm To 4.1 Gm Available In St Tip And J Tip. , 0.014” Diameter Ptca Wire With Directly Jointed Sus And Nitinol Shaft Through Duocore Technology For Superior Torque Transmission. Available In Various Tip Loads Of ( Usfda & Japan Pmda Approved ) –Tip Load Of 1.0 Gf , 0.014” Diameter Ptca Wire With Directly Jointed Sus And Nitinol Shaft Through Duocore Technology For Superior Torque Transmission. Available In Various Tip Loads Of ( Usfda & Japan Pmda Approved ) – Tip Load Of 0.6 Gf , 0.014” Diameter Ptca Wire With Directly Jointed Sus And Nitinol Shaft Through Duocore Technology For Superior Torque Transmission. Available In Various Tip Loads Of ( Usfda & Japan Pmda Approved ) –Tip Load Of 3.6 Gf , Coronary Wire For Rotational Atherectomy With Normal Support / Floppy Tip , Coronary Wire For Rotational Atherectomy With Extra Support , Ptca Extension Wire For Abbott Wires , Ptca Extension Wire For Asahi Wires , Ptca Extension Wire For Terumo Wires , Supportive 0.014 Stainless Steel Peripheral Wire With 4 Cm Radiopaque Tip Coil And Shapeable “Core-To-Tip” Design For Precise Steering And Tip Control; Available In 130, 190, 300 Cm Lengths , Supportive 0.035 Peripheral Guide Wire With Soft Atraumatic Tip; One-To-One Torque Response Provides Exceptional Steerability. Available In 145, 190, 300 Cm Lengths , Workhorse And Supportive 0.014” Hybrid Wire Which Offers The Outstanding Durability Of Nitinol With Excellent Steering Of Stainless Steel ( Metals Are Fused Together As If Its One ) , Shapable And Ultra Durable Nitinol Tip , Stainless Steel Body For Excellent Torque And Navigation.Tip Load Of 2.8Gms And 3.5 Gms And Available In 190 , 300 Cm Lengths. , 0.014 Peripheral Wire To Cross Cto 40-200 Gm Tip Load With Standard And Double Length , 0.014 Peripheral Hybrid ( Nitinol And Steel ) Workhorse Wire With Tip Load Of 2.8-3.5 Gm With Standard And Double Length , 0.014 Peripheralstainless Steel Workhorse Wire With 4 Cm Radio-Opaque Tip And Shapeable Core To Tip Design With Lengths Of 130 -200 Cm , 0.018 Stainless Steel Supportive Peripheral Guidewire With 5 Cm Platinum / Nickel Tip With Shapeable Core To Tip Design With Length Of 130-300 Cm , 0.014 Peripheral Cto Wire With 65Cm Hydrophilic Tip With Lengths Of 300 Cm And Tip Load Of 12G, 18G, 25G & 30G , 0.018 Stainless Steel Alloy Core Peripheral Guide Wire, Ice Hydrophillic Coating On Distal 8Cm & 11Cm Shapeable Atraumatic Tip With Lengths Of 200, 300 Cm , 0.014Vstainless Steel Alloy Core Peripheral Guide Wire, Ice Hydrophillic Coating On Distal 8Cm & 11Cm Shapeable Atraumatic Tip With Lengths Of 180- 300 Cm , Microcatheters / Support Catheters For Coronary And Peripheral Use; Infusion Catherters; Thrombectomy System Catheter & Accessories , Dual Lumen Catheter For Use With Dual 0.014 Coronary Angioplasty Wires For Use Such As Advancing Wire From Inside Stent Into Side Branch While Maintaining Distal Access ( Examples: Crusade Catheter; Twin-Pass Catheter ) , Double Lumen Catheter , Hydrophilic Coating 38 Cm , Usable Length 145 Cm , 6.5 Mm Tip To Otw Port , Tapered Soft Tip , Oval Design , Double Statinless Steel , Tip 1.5 Frex Sasuke Catheter , Complex Channel Or Micro-Channel Crossing Catheter With Hydrophilic Coating Of Distal Segment, Kink Resistant Tapered Tip Of 0.016, Tungsten Braiding, +10 Elliptical Stainless Steel Braids For Better Support ( 130 - 140 Cm For Antegrade Technique ) . Ex. Corsair , Complex Channel Or Micro-Channel Crossing Catheter With Hydrophilic Coating Of Distal Segment, Kink Resistant Tapered Tip Of 0.016, Tungsten Braiding, +10 Elliptical Stainless Steel Braids For Better Support ( 150-160 Cm For Retrograde Technique ) . Ex Corsair , Coronary Micro-Catheter With Distal Diameter Of 1.8 Fr Or Less, 130-150 Cm Long, Flexible Tip With Outer And Inner Taper With Gold Marker At Distal Tip For Enhanced Distal Visibility To Cross Difficult Lesions. Ex. Finecross Mg , Coronary Micro-Catheter With Tip Entry Profile Of 1.4 Fr Or Less, Shaft Diameter Of 1.9 F Or Less 135-150 Cm Long, Flexible Tip With Taper To Cross Difficult Lesions. Ex. Caravel , Micro-Catheter With Od Of 2.8 F / 2.1F Or Less With Lengths Between 110-140 Cm Compatible With 0.018 Coils And With Radio-Opaque Markers Ex. Progreat , Micro-Catheter With Od Of 2.8 F / 2.1F Of Less With Lengths Between 110-140 Cm Compatible With 0.018 Coilsand With Radio-Opque Markers Supplied As System With 0.018 Hydrophilic Coated Angled Tip Wire With Radio-Opaque Tip Ex. Progreat System With Glidewire Gt 0.018 , 2.6F 150 Cmsupport Catheter With Hydrophilic Coating With Braided Shaft And Softtipcompatible With 0.18 Guidewire Ex. Cook Cxi Support Catheter , 130- 150 Cmlength Support Cathetesr With Three Radioopaque Markers With Transperent Shaft Compatible With 0.014 And 0.18 Guidewire Ex. Rubicon Bs. , 4.0 F 150 Cmsupport Catheter With Hydrophilic Coating With Braided Shaft And Softtipcompatible With 0.35 Guidewire Ex. Cook Cxi Support Catheter , Infusion Catheter For Peripheral Thrombolysis With Varied Infusion Lengths :Diameter 4, 5 F. Active Segment Length 10-20 Cm And Catheter Length 65 And 135 Cm. , Mechanical Thrombectomy System Canister , Mechanical Thrombectomy System Large Lumen Aspiration Tubing , Mechanical Thrombectomy System Separator , Mechanical Active Suction Thrombectoly System Straight Tip Catheter , Mechanical Active Suction Thrombectomy System Torq Tip Catheter , Coronary Guide Catheters And Guide Extenders , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Judkins Left , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F With No Side Holes - Judkins Left , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F With Side Holes - Judkins Left , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F With No Side Holes - Judkins Left , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 8F With No Side Holes - Judkins Left , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 8F With Side Holes - Judkins Left , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Judkins Right , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F With No Side Holes - Judkins Right , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F With Side Holes - Judkins Right , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F With No Side Holes - Judkins Right , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 8F With No Side Holes - Judkins Right , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 8F With Side Holes - Judkins Right , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F - Mpa 1 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F - Mpa1 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F - Mpa1 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 8F - Mpa1 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F - Mpa2 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F - Mpa2 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F - Mpa2 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 8F - Mpa2 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Ima90 Cm Length , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F With No Side Holes Ima - 90 Cm Length , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Al 0.75 With No Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F With No Side Holes Al0.75 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Al1 With No Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F With No Side Holes Al1 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F With Side Holes Al1 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F With No Side Holes Al1 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 8F Al1 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Al2 With No Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F With No Side Holes Al2 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F With Side Holes Al2 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F With No Side Holes Al2 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 8F Al2 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Ar1 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F With No Side Holes Ar1 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F With No Side Holes Ar1 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Ar2 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F With No Side Holes Ar2 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F With No Side Holes Ar2 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Left Coronary Bypass ( Lcb ) , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Left Coronary Bypass ( Lcb ) , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Right Coronary Bypass ( Rcb ) , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Right Coronary Bypass ( Rcb ) , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Hockey Stick , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Hockey Stick , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Hockey Stick , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Ebu 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Ebu 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Ebu 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Ebu 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Ebu 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Ebu 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Ebu 3.0 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Ebu 3.5 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Ebu 4.0 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Ebu 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Ebu 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Ebu 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Cls 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Cls 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Cls 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Cls 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Cls 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Cls 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Cls 3.0 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Cls 3.5 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Cls 4.0 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Cls 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Cls 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Cls 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Q 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Q 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Q 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Q 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Q 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Q 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Q 3.0 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Q 3.5 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Q 4.0 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Q 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Q 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Q 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Voda 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Voda 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Voda 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Voda 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Voda 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Voda 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Voda 3.0 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Voda 3.5 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Voda 4.0 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Voda 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Voda 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Voda 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Xb 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Xb 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Xb 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Xb 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Xb 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Xb 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Xb 3.0 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Xb 3.5 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Xb 4.0 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Xb 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Xb 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Xb 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Xb Lad 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Xb Lad 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Xb Lad 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Xb Lad 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Xb Lad 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Xb Lad 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Xb Lad 3.0 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Xb Lad 3.5 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Xb Lad 4.0 With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Xb Lad 3.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Xb Lad 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Xb Lad 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Right For Superior Take Off Of Rca 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Right For Superior Take Off Of Rca 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F Right For Superior Take Off Of Rca 4.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Right For Superior Take Off Of Rca 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Right For Superior Take Off Of Rca 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F Right For Superior Take Off Of Rca 4.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Right For Superior Take Off Of Rca 3.5 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Right For Superior Take Off Of Rca 4.0 , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 7F Right For Superior Take Off Of Rca 4.5 , Coronary Guide Catheter With Henka Braiding 6Fr , 7Fr 3Rd Degree Curve In Left System All Assorted Sizes , Ptca Guiding Catheter It Should Be Large Lumen. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F With No Side Holes - Ikari Left Shape , Ptca Guiding Catheter It Should Be Large Lumen. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 6F With No Side Holes - Ikari Right Shape , Ptca Guiding Catheter It Should Be Large Lumen. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F With No Side Holes - Ikari Left Shape , Ptca Guiding Catheter It Should Be Large Lumen. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip - 5F With No Side Holes - Ikari Right Shape , Ptca Guiding Catheter Mother And Child System 6F In 7F , Ptca Guiding Catheter Mother And Child System 5F In 6F , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip And Be Suited For Radial Access Left Coronary Angioplasty- 5F With No Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip And Be Suited For Radial Access Right Coronary Angioplasty- 5F With No Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip And Be Suited For Radial Access Left Coronary Angioplasty- 6F With No Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip And Be Suited For Radial Access Right Coronary Angioplasty- 6F With No Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip And Be Suited For Radial Access Left Coronary Angioplasty- 7F With Side Holes , Ptca Guiding Catheter It Should Be Large Lumen, Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Atraumatic Soft Tip With Radio Opaque Markerband At The Tip And Be Suited For Radial Access Right Coronary Angioplasty- 7F With Side Holes , Ptca Guiding Catheter With Full Braiding And Polyurethane Atraumatic Tip With Excellent Shape Retention With Heat Resistance; 2Nd Cureve Should Be Reinforced And Extra Third Curve To Be Present; The Supportive Shaftfshould Be Softer Towards The Tip. , Guidezilla Type Catheter With Hypotube Shaft, 6F / 7F / 8F, Rapid Exchange With 145-150 Cm Working Length, Tip Radiopaque Marker. ( Coronary Guide Extender ) , Gudie Extender For Coronary Use With Integrated Trapping Balloon For Trapping 0.014 Guidewire. , Guideliner / Telescope Type Catheter With Ribbon Shaped Shaft, 5F / 5.5F / 6F / 7F / 8F, Rapid Exchange With 145-150 Cm Working Length, Tip Radiopaque Marker. ( Coronary Guide Extender ) , Coronary And Peripheral Angioplasty Balloons Including Scoring Balloons / Balloon In Balloon / Dcb , 1.2-4.0Mm Diameters ( Lengths:6, 8, 12, 15, 20, 30Mm ) . Ce Approved Semi-Compliant Balloon Dilatation Catheter Available In Rx With Multi-Layer Balloon, Crossflex Technology, Streamlined Tip, Laser Bond Technology On Distal Tip With Crossing Profile Of 0.021 And Tip Entry Profile Of 0, 017, Nominal Pressure Of 8 Atm And Rbp Of 14Atm, Flexible Tungsten Markers To Ensure Low Crossing Profile And Excellent Deliverability , 2.0-4.5Mm Diameters ( Lengths:8, 12, 15, 20, 25Mm ) .Ce Approved Non-Compliant Balloon Dilatation Catheter With Tri Fold Layer Balloon, Tip Entry Profile Of 0.018 Nominal Pressure Of 12 Atm And Rbp Of 18 Atmspecialized Tip Andflexible Tungsten Markers To Ensure Flat Compliance, Concentrated Dilatation Force And Excellent Deliverability , Cto Indicated And Usfda Approved Semi-Complaint Balloon With Slim Seal Technology On Distal Tip With Lesion Entry Profile Of 0.016, Crossing Profile Of 0.021 And Single Flexible Tungsten Marker Available In Unique Diameter Of 1.2Mm With Variety Of Lengths , Usfda Approved Semi-Complaint Coronary Balloon With Slim Seal Technology On Distal Tip With Crossing Profile Of 0.021”, Lesion Entry Profile Of 0.017” And Microglide Coating Available In Diameter 2.25-5.00Mm And Lengths 6-30Mm , Usfda Approved Non-Complaint Coronary Balloon With Multilayer Crossflex Balloon Technology And Round Tip With Lesion Entry Profile Of 0.018” Available In Diameter 1.5Mm-5Mm And Lengths In 6Mm-25Mm With Skive Technology On Mid Shaft Of Dilatation Catheter , Bi-Segment Inner Shaft For Perfect Mix Of Push And Deliveribility. Low Entry Profile Of 0.0017 And Crossing Profile Of 0.026. High Rbp Of 20Atm With Compliance Of 3%. Allows Usage Of 2 Monorail Catheter In 6F Guiding Catheter. Broad Size Matrix From 2.00Mm To 6.00Mm. Improved Profiles For Kbt In 6F Guiding Catheter ( Us Fda Approved ) , Rapid Exchange Balloon Dilatation Catheter With Special Features , Low Entry Profile Wth Ecellent Pushability Based On Single Segment Shaft Construction ( Us Fda Approved ) , Special Plaque Modifing Balloons With Atherotomes ( Microsurgical Blades With Flex Points ) In Varying Lengths For Predictable & Consistent Dilatation. Lesion Entry Profile Of 0.020 And Mid Balloon Profile Ranging From 0.037 To 0.042. Compliance Of 5%. ( Usfda Approved ) , Ptca Balloon With 1.25 X6 Mm Size Zero Fold – Ideal For Crossing Complex And Cto Lesions;Tip Entry Profile Of .016’ ;Platinum Iridium Marker Bands;6 Fr Compatible For Kissing Ballon Technique; Supple Balloon Material For Better Navigation. Flexible Tip For Better Crossability. Stepwise Transition Stiffening For More Pushability. Available In Rx And Otw;Specialized Coating For Improved Crossability. Nominal 8 Atm And Rbp 14 Atm;Diameters Available 1.5, 2.0, 2.25, 2.5, 2.75, 3.0 3.5 4.0 Mm; Lengths Available In 6, 10, 12, 15, 20, 25 & 30 Mm , Nc Ptca Balloon Low-Profile Highly Flexible Tip —0.41 Mm ( 0.016” ) Lesion Entry Profile; Lowest Balloon Profile And Excellent Rewrap : Fulcrum Plus Balloon Material And Unique Mini Wrap Folding Process Specialized Coating For Optimal Lubricity. Lowest Longitudinal Growth For More Exact Sizing. High Pressure Capabilities With Low Profile Because Of Soft Fulcrum Balloon Material, Gold Swaged Marker Bands For Low Profile Less Than 4% Longitudinal Growth At Rbp, Available Diameter2.0, 2.5, 2.75, 3.0, 3.5 , 4.0 Mm Lengths Available 6, 9, 12, 15, 21 & 27 Mm ;Tip Entry Profile Of .016And Crossing Profile Of .026 For A 3Mm Balloon Nominal At 10 Atm And Rated Burst Pressure Of 18 Atm;Shaft Length Of 142 Cm , Ptca Balloon With 1.0-1.5 Mm Diameter In Size– Ideal For Crossing Complex And Cto Lesions;Tip Entry Profile Of .016’ Single-Material Tip;5 Fr Compatible; Hydrophilic Distal Tip To Guidewire Exit Marker And Hydrophobic Guidewire Lumen. Flexible Tip For Better Crossability. Stepwise Transition Stiffening For More Pushability. Available In Rx ;Specialized Coating For Improved Crossability. Nominal 6 Atm And Rbp 16 Atm. Lengths Available In 5, 8, 10, 12, 15, 20 Mm , Ptca Balloon With 1.75-4.0 Mm Diameter ;Tip Entry Profile Of .016’ Single-Material Tip;6 Fr Compatible For Kissing Ballon Technique; Hydrophilic Distal Tip To Guidewire Exit Marker And Hydrophobic Guidewire Lumen. Sub-Zero Tip Technologyfor Better Crossability. P-Tech Shaft Design For Kink Resistsnt And Better Deliverability. Available In Rx And Otw ;Specialized Coating For Improved Crossability. Nominal 6 Atm And Rbp 14 Atm. Lengths Available In 5, 8, 10, 12, 15, 20, 30 Mm , Nc Ptca Balloon Low-Profile Highly Flexible Tip —0.30Mm ( 0.0336 ) Lesion Crossing Profile; Lowest Balloon Profile And Excellent Rewrap : Enchanced Distal Z-Tip; Hydrophilic Distal Tip To Guidewire Exit Marker And Hydrophobic Guidewire Lumen Coating ; Zero Tranition Between Distal Leading Tip And 0.014 Guidewire; Available Diameter1.75, 2.0, 2.5, 2.75, 3.0, 3.25, 3.5 , 3.75 4.0, 4.5, 5.0 Mm Lengths Available 8, 10, 12, 15, 18 Mm ; Nominal At 10 Atm And Rated Burst Pressure Of 18 Atm;Shaft Length Of 140 Cm , Non-Compliant Rapid Exchange Ptca Balloon, With Enhanced Push Ability, Trackability And Kink Resistance, Rbp 22 Atm, Tip Entry Profile = 0.016” 2.0-5.0 Mm Diameter, Length 6Mm To 15Mm , Ultra Low Entry Profile Balloon With 0.016 Entry Profile, Thin Marker Of 25?M And Core Wire Shaft For Better Pushability With Wide Range From 1Mm To 4Mm Diameter. , Ptca Pre-Dilatation, Monorail Balloon ( Semi Compliant ) . Hypotube Shaft Design, Low Entry Profile ( <0.016 ) And 5F Guiding Catheter Compatibility And Compatibel With 6F Guide For Kbi. Diameter ( Mm ) - 1.20 / 1.25, 1.5, 2.0, 2.5, 2.75, 3, 3.25, 3.5, 4.0 Length - 8-10Mm, 12-15Mm, 18-20Mm, 25Mm, 30Mm Or More. , Ptca Pre-Dilatation, Over The Wire Balloon ( Semi Compliant ) . Hypotube Shaft Design, Low Entry Profile ( <0.016 ) And 5F Guiding Catheter Compatibility. Diameter ( Mm ) - 1.20 / 1.25, 1.5, 2.0, 2.5Length - 8-10Mm, 12-15Mm Or More. , Ptca Balloon Less Than 0.016 Tip Profile Low Profile Rapid Exchange Semi-Compliant Balloon With With Rbp Of At Least 14 Atm With 2.3 F Shaft , Ptca Balloon Less Than 0.016 Tip Profile Low Profile Rapid Exchange Non-Compliant Balloon With With High Rbp Of At Least 22 Atm , Japan Pmda Approved High Pressure Ptca Balloon With Small Entry Profile Of 0.43Mm And Small Balloon Profile Of 0.034” With Special Silicon Coating On Balloon To Avoid Mellon Seed Effect. , Ultra-Low Entry Profile Semi Compliant Balloon With .40Mm Or 0.016” And Entry Profile From 1.25*10 To 2.25*10 Remains Same For Exceptional Crossability Even With Higher Diameter Balloon. , Non-Compliant Rapid Exchange Ptca Balloon, With Enhanced Push Ability, Trackability And Kink Resistance, Rbp 22 Atm, Tip Entry Profile = 0.016” 2.0-5.0 Mm Diameter, Length 6Mm To 15Mm , High Pressure Triple Layer Ptca Balloon With Small Entry Profile Of 0.43Mm And Small Balloon Profile Of 0.034” With Large Pressure Working Range From 12Atm ( Np ) To 22Atm ( Rbp ) . , Ptca High Pressure Balloon With Ballon-In Ballloon Design With Rbp Up To 32 Atm , Cto Non-Compliant Ptca Balloon With Rbp Of 23 Mm Hg With Crossing Profile Of .0195 With Lengths Of 10-15 Mm And Diameter Of 0.85 Mm , Ptca Pre-Dilatation Monorail Semi -Compliant Balloon, With Lowest Tip Entry Profile Of 0.016, Lowest Crossing Profile For Crossing Cto Or Difficult To Cross Lesions And Smallest Balloon Size Of 1.0 Mm Diameter And Length Of 6-8 Mm With Single Marker At The Central Of The Balloon. Other Diameters Of 1.25Mm, 1.5Mm, 2Mm, 2.5Mm, 3Mm. Other Lengths Of 10-12Mm, 15-18Mm, 20-22Mm, 25Mm Or More With Lubricious Coating On Balloon And Tip. , Ptca Pre-Dilatation Over The Wire Semi -Compliant Balloon, With Lowest Tip Entry Profile Of 0.016, Lowest Crossing Profile For Crossing Cto Or Difficult To Cross Lesions And Smallest Balloon Size Of 1.0 Mm Diameter And Length Of 6-8 Mm With Single Marker At The Central Of The Balloon. Other Diameters Of 1.20 / 1.25Mm, 1.5Mm, 2Mm, 2.5Mm Other Lengths Of 6-12Mm, 15-18Mm Or More With Lubricious Coating On Balloon And Tip. , Ptca Pre-Dilatation Catheter With 2.5F Flexible Tip;Hydrophilic Coated Balloon, Tri-Fold Ballon With Superior Re-Wrapping With Diameters Between 2.25 To 5.0 Mm And Various Lengths And Rbp Upto 18-20 Atm. , High Pressure Non-Compliant Balloon With >20 Atm Rbp, Smooth, Rounded Distal Tip And No Edge Overdilatation At Higher Pressure; With Least Balloon Overhang At The Edges. Diameter ( Mm ) : 2, 2.5, 2.75, 3.0, 3.25, 3.5, 3.75, 4, 4.5, 5.0. Length ( Mm ) : Minimum 6-8Mm To >20Mm. , High Pressure Non-Compliant Balloon With Rated Burst Pressure Of 18 Atm With Low Profile Including Tip-Entry Profile Of 0.016 And <4% Longitudinal Growth At Rbp. Markers Should Be Designed For Low Profile. , High Pressure Non-Compliant Balloon Withrbp Of >25Atm, Smooth, Rounded Distal Tip And No Edge Overdilatation At Higher Pressure; With Least Balloon Overhang At The Edges. Diameter ( Mm ) : 2, 2.5, 2.75, 3.0, 3.25, 3.5, 3.75, 4, 4.5, 5.0. Length ( Mm ) : Minimum 6-8 Mm To >20Mm. , Drug Coated Balloon For Coronary Use In Various Sizes , Scoring Balloon Catheter. Nitinol Scoring Element With Three Rectangular Spiral Sheets On A Semi-Compliant Balloon For Coronary And Peripheral Applications Diameter ( Mm ) : 2.0, 2.5, 3.0, 3.5. Length ( Mm ) : 10, 15, 20. , Peripheral Pta Balloon Otw 0.014 Compatible; 4-6F Sheath Compatible; With Shaft Length Of >=130Cm With Diameter Of 1-4 Mm With The Ballon Length At Least Up To 200 Mm With Specialized Coating For Good Pushability With Rbp At Least 14 Atm , Peripheral Pta Balloon Rapid Exchange 0.014 Compatible; 6F Sheath Compatible; With Shaft Length Of >=130Cm With Diameter Of 4-7 Mm With The Ballon Length 20-60 Mm With Specialized Coating For Good Pushability With Rbp At Least 14 Atm. , Peripheral Pta Over The Wire Balloon / Rapid Exchange 0.014 Compatible; 4-6F Sheath Compatible; With Shaft Length Of >75 And >=130Cm With Diameter Of 1-5 Mm With Various Lengthwith Specialized Coating For Good Pushability With Rbp At Least 14 Atm. , Peripheral Pta Balloon Otw 0.014 Compatible; 4-6F Sheath Compatible; With Shaft Length Of >=130Cm With Diameter Of 1.5-5 Mm With The Ballon Length At Least Up To 300 Mm With Dual Layer Specialized Coating For Good Pushability & Checker Flex Points For Unmatched Trackability With Rbp At Least 14 Atm , Peripheral Pta Balloon Otw 0.018 Compatible; 4-6F Sheath Compatible; With Shaft Length Of >=130Cm With Diameter Of 2-6 Mm With The Ballon Length At Least Up To 200 Mm With Specialized Coating For Good Pushability With Rbp At Least 14 Atm , Peripheral Pta Balloon Otw 0.35 Compatible; 5-6F Sheath Compatible; With Shaft Length Of >75 And >=130Cm With Diameter Of 3-12 Mm With The Ballon Length 20-300 Mm And Marker Bands Are Designed To Increase Procedure Efficiency By Minimizing Fluoroscopy Exposure , Peripheral Pta Balloon Otw 0.35 Compatible; 4F Sheath Compatible; Tapered Diameter Balloon With Shaft Length Of >=50 And >=130Cm With Diameter Of 1.5-4 Mm With The Ballon Length 20-220 Mm , Peripheral Pta Balloon Otw 0.35 Compatible; 5-6F Sheath Compatible; With Shaft Length Of >75 And >=130Cm With Diameter Of 3-12 Mm With The Ballon Length 40-250 Mm , Peripheral Pta Balloon Otw 0.35 Compatible; 7F Sheath Compatible; With Shaft Length Of >75 And >=130Cm With Diameter Of12-14 Mm With The Ballon Length 20 -80Mm , Peripheral Balloon, Multilayer Non Compliant Very High Pressure Up To 30-40 Atm, Over-The-Wire For Pre-Dilatation, Over 0.035 Wire; With Shaft Length Of >75 And >=130Cm With Diameter Of5-12 Mm With The Ballon Length 20 -86Mm , Peripheral Balloon, Non Compliant Very High Pressure Up To 30 Atm, Over-The-Wire For Pre-Dilatation, 6F Compatible, Over 0.035 Wire. Suitable For Iliac Pta , Pta Balloon For Carotid Use Rapid Exchange 0.14 And 0.18 Compatible; 5-7F Sheath Compatible; With Shaft Length Of >75 And >=130Cm With Diameter Of 3-12 Mm With The Ballon Length 20-80 Mm , Peripheral Pta Balloon Otw With Nitinol Cage That Allow 1:1 Vessel Sizing 0.035 - 0.014 Compatible; 4-6F Sheath Compatible; With Shaft Length Of>=75 Cm, >=130Cm With Diameter Of 2.5-6.0 Mm With The Ballon Length 80-200 Mm Ex. Chocolate Balloon , Peripheral Cutting Balloon 0.014 And 0.018 Compatible With 2-8 Mm Diameter Length Up To 25 Mm, 6-7F Compatible. , Drug Coated Balloon To Minimze Restenosis In Peripheral Vascular Disease ( For Sfa And Infra-Popliteal Use ) .014-0.035 Compatible With Diameter Of 2-8 Mm And Ballon Length Of 30-200 Mm Ex. Ranger Bs, Lutonix Bard; Inpact Medtronic , Bare Metal Stents / Des / Covered Stents For Coronary Use , Balloon Pre-Mountedcobalt Chromiumstent, With Thin Struts As Accepted In Interventional Cardiology. Minimum Diameter Range Of 2.5 To 4.0 With Minimum Length Range Of 9-28 Mm..Should Be Dgci Approved And Ce Marked.Quotation Should Include All Sizes Of Quoted Stent As Marketed By Manufacturer. , Balloon Pre-Mountedcobalt Chromiumstent, With Thin Struts As Accepted In Interventional Cardiology. Minimum Diameter Range Of 2.5 To 4.0 With Minimum Length Range Of 9-28 Mm.. Should Be Dgci Approved, Ce Marked And Usfda Approved.Quotation Should Include All Sizes Of Quoted Stent As Marketed By Manufacturer. , Balloon Pre-Mounted Platinum- Chromiumstent, With Thin Struts As Accepted In Interventional Cardiology. Minimum Diameter Range Of 2.5 To 4.0 With Minimum Length Range Of 9-28 Mm..Should Be Dgci Approved And Ce Marked.Quotation Should Include All Sizes Of Quoted Stent As Marketed By Manufacturer. , Balloon Pre-Mounted Platinum- Chromiumstent, With Thin Struts As Accepted In Interventional Cardiology. Minimum Diameter Range Of 2.5 To 4.0 With Minimum Length Range Of 9-28 Mm..Should Be Dgci Approved, Ce Marked And Usfda Approved.Quotation Should Include All Sizes Of Quoted Stent As Marketed By Manufacturer. , Balloon Pre-Mounted Platinum- Chromium Stent, Ultra Small Strut Thickness For Small Vessels With Low Entry Profile.Diameters: ( Mm ) : 2.0, 2.25 Length :- <10 Mm To >23 Mm. Should Be Dgci Approved And Ce Marked. Quotation Should Include All Sizes Of Quoted Stent As Marketed By Manufacturer. , Balloon Pre-Mounted Platinum- Chromium Stent, Ultra Small Strut Thickness For Small Vessels With Low Entry Profile.Diameters: ( Mm ) : 2.0, 2.25 Length :- <10 Mm To >23 Mm. Should Be Dgci Approved, Ce Marked And Usfda Approved. Quotation Should Include All Sizes Of Quoted Stent As Marketed By Manufacturer. , Covered Stents For Coronary Use With Ptfe Layer Sandwiched Between Two Stent Layers , Everolimus Coated Drug Eluting Stent, Usfda Approved With Platinum Chromium Base , Everolimus Coated Drug Eluting Stent, Usfda Approved With Cobalt Chromium Base , Everolimus Coated Drug Eluting Stent, Usfda Approved With Platinum Chromium Base With Length Exceeding 33 Mm , Everolimus Coated Drug Eluting Stent, Usfda Approved With Cobalt Chromium Base With Length Exceeding 33 Mm , Everolimus Coated Drug Eluting Stent, Usfda Approved With Platinum Chromium Base With Length Exceeding 38 Mm , Everolimus Coated Drug Eluting Stent, Usfda Approved With Cobalt Chromium Base With Length Exceeding 38 Mm , Zotarolimus Coated Drug Eluting Stent, Usfda Approved With Platinum Chromium Base , Zotarolimus Coated Drug Eluting Stent, Usfda Approved With Cobalt Chromium Base , Zotarolimus Coated Drug Eluting Stent, Usfda Approved With Platinum Chromium Base With Length Exceeding 33 Mm , Zotarolimus Coated Drug Eluting Stent, Usfda Approved With Cobalt Chromium Base With Length Exceeding 33 Mm , Zotarolimus Coated Drug Eluting Stent, Usfda Approved With Platinum Chromium Base With Length Exceeding 38 Mm , Zotarolimus Coated Drug Eluting Stent, Usfda Approved With Cobalt Chromium Base With Length Exceeding 38 Mm , Sirolimus Coated Drug Eluting Stent, Ce Marked, Dcgi Approved With Cobalt Chromium Base With 60 Or Less Micron Strut Thickness With Length Of Greater Than 38 Mm , Sirolimus Coated Drug Eluting Stent, Ce Marked, Dcgi Approved, Japan Pmda Approved With Abluminal Drug Bireabsorbable Coating With Cobalt Chromium Base With 80 Or Less Micron Strut Thickness With Length Upto At Least 38 Mm , Sirolimus Coated Drug Eluting Stent, Ce Marked, Dcgi Approved With Cobalt Chromium Base , Sirolimus Coated Drug Eluting Stent, Ce Marked, Dcgi Approved With Platinum Chromium Base , Sirolimus Coated Drug Eluting Stent, Dcgi Approved With Cobalt Chromium Base , Sirolimus Coated Drug Eluting Stent, Dcgi Approved With Platinum Chromium Base , Everolimus Coated Drug Eluting Stent, Ce Marked And Dcgi Approved With Platinum Chromium Base , Everolimus Coated Drug Eluting Stent, Ce Marked And Dcgi Approved With Cobalt Chromium Base , Everolimus Coated Drug Eluting Stent, Ce Marked And Dcgi Approved With Platinum Chromium Base With Length Exceeding 33 Mm , Everolimus Coated Drug Eluting Stent, Ce Marked And Dcgi Approved With Cobalt Chromium Base With Length Exceeding 33 Mm , Everolimus Coated Drug Eluting Stent, Ce Marked And Dcgi Approved With Platinum Chromium Base With Length Exceeding 38 Mm , Everolimus Coated Drug Eluting Stent, Ce Marked And Dcgi Approved With Cobalt Chromium Base With Length Exceeding 38 Mm , Everolimus Coated Drug Eluting Stent, Dcgi Approved With Cobalt Chromium Base , Everolimus Coated Drug Eluting Stent, Dcgi Approved With Cobalt Chromium Base With Length Exceeding 33 Mm , Everolimus Coated Drug Eluting Stent, Dcgi Approved With Cobalt Chromium Base With Length Exceeding 38 Mm , Zotarolimus Coated Drug Eluting Stent, Ce Marked And Dcgi Approved With Platinum Chromium Base , Zotarolimus Coated Drug Eluting Stent, Ce Marked And Dcgi Approved With Cobalt Chromium Base , Zotarolimus Coated Drug Eluting Stent, Ce Marked And Dcgi Approved With Platinum Chromium Base With Length Exceeding 33 Mm , Zotarolimus Coated Drug Eluting Stent, Ce Marked And Dcgi Approved With Cobalt Chromium Base With Length Exceeding 33 Mm , Zotarolimus Coated Drug Eluting Stent, Ce Marked And Dcgi Approved With Platinum Chromium Base With Length Exceeding 38 Mm , Zotarolimus Coated Drug Eluting Stent, Ce Marked And Dcgi Approved With Cobalt Chromium Base With Length Exceeding 38 Mm , Sirolimus Coated Drug Eluting Stent Withjapan Pmda Approved, Ce Marked, Dcgi Approved With Cobalt Chromium Base , Sirolimus Coated Drug Eluting Stent With Bio-Degradable Polymer With Abluminal And Specializd Gradient Coating, Ce Marked, Dcgi Approved With Cobalt Chromium Base , Sirolimus Coated Drug Eluting Stent With Bio-Degradable Polymer, Ce Marked, Dcgi Approved With Platinum Chromium Base , Sirolimus Coated Drug Eluting Stent With Bio-Degradable Polymer, Dcgi Approved With Cobalt Chromium Base , Sirolimus Coated Drug Eluting Stent With Bio-Degradable Polymer, Dcgi Approved With Platinum Chromium Base , Temporary Pacing Leads, Bioptomes, Snares, Embolic Protection Devices, Thrombus Aspiration Catheters , Bipolar Temporary Pacing Leads.Adult ( 5F ) . , Bipolar Temporary Pacing Leads.Adult ( 6F ) . , Bipolar Temporary Pacing Leads.With Balloon Tip; Adult ( 5F ) . , Bipolar Temporary Pacing Leads.With Balloon Tip; Adult ( 6F ) . , Bioptome 3-4F For Retrieval Of Stents Etc From Coonary Artery , Bioptome 5.2 F For Controlled Release Of Pda Coils , Cardiac Bioptomes For Endomyocardial Biopsy. ( 6F ) , Cardiac Bioptomes For Endomyocardial Biopsy. ( 7F ) , Snares: Dual Plane Snare System With Radio-Opaque Loop ( 2, 4 Mm ) 150 Cm Shaft Length , Snares: Dual Plane Snare System With Radio-Opaque Loop ( 5, 10 Mm ) ) 110 Cm Shaft Length , Snares: Dual Plane Snare System With Radio-Opaque Loop ( 15, 20, 30 Mm ) 110 Cm Shaft Length , Amplatz Goose Neck Snare Kit ( Small Size 5-10 Mm ) With 120 Cm Shaft Length , Amplatz Goose Neck Snare Kit ( Large Size 15-35 Mm ) With 120 Cm Shaft Length , Snare- 4 Loop Snare 6F Ex. Cloversnare From Cook , Micro Snare Capable Of Delivery Through 0.014 Diameter Lumen Of Microcatheter Or Balloon Catheter With Helical Loop Design And Available Sizes Of 2, 4 Or 7 Mm. , Radio Opaque Micro Snare, Small Loop, 90 Degree With Kink Resistant Shaft. , Grasp Basket With Radio Opaque Helical Loop Basket, 3F / 4F With Kink Resistant Shaft. , Nitinol Basket Type Embolic Protection Device In Sizes 3, 4, 5, 6, 7 Mm Diameter Filtersize With Wire Length Of 190 Cm And 320 Cm Compatible With 0.014 Wire Suitable For Coronary, Carotid And Peripheral Distal Embolic Protection Ex. Spider Fx , Polyurethane Filter With Suspended Nitinol Loop Suitable For Vessel Size From 3.5 - 5.5 Mm Ex. Filterwire Ez , Filter Type Rapid Exchange Cerebral Protection Device System Compatible With 0.014 Wire, 2.5-7.0 Mm Diameter Ex. Emboshield , Intra Coronary Thrombus Extraction Catheter With Large Lumen, Side Hole, Monorail Over 0.014 Guide -Wire. 6F , Intra Coronary Thrombus Extraction Catheter, Short Tip Monorail Segment, Big And Round Suction Lumen With Removable Core Wire For Enhanced Pushability, Tip Hydrophilic Coating, 6F Guide And 0.014 Wire Compatibility. 6F , Thrombus Aspiration Catheter Of 0.78 Mm2 Suction Area With Stainless Steel Wire Braiding And Guide Wire Type Stylet, 6.0Mm Tip Length For Making Aspiration Inlet Closer To The Target Thrombus And 10Cm-Length Depth. , Thrombus Aspiration System With Larger Lumen 6 F Compatibility With Large Extraction Area Of Min 5.4 Mm ( Sq ) And A Gw Lumen Length Of 240 Mm , Dual Lumen Monorail System With 60 Cc Syringe. , Thrombus Aspiration System With Larger Lumen 6 F And 7F Compatibility With Large Extraction Area ) And A Gw Lumen Length Of 10 -100 Mm , Dual Lumen Monorail Systemshaft Diameter Of 3.9-4.2F And Effective Shaft Length Of 140 Cm , Embolisation Therapy Related Items , Pda Coils Of Different Size And Diameter. , Delivery System For Pda Coils For Controlled Deployment And Release With Ability To Retrieve Coil If Needed ( Before Release ) , Platinum Fibered 0.018Micro-Coils - Pushable With Uniform Loop Diameters Ex. - Nester , Platinum Fibered 0.035Coils - Pushable With Uniform Loop Diameters Ex. Nester , Platinum Fibered 0.018Micro-Coils - Pushable With Different Diameter Sizes In Different Loops Ex. Tornado , Platinum Fibered 0.035Coils - Pushable With Different Diameter Sizes In Different Loops Ex. Tornado , Platinum Fibered 0.018Micro-Coils - Pushable Straight Coils With Small Lengths Of 0.5-1.0 Cm Ex. Hilal , Platinum Fibered 0.018Micro-Coils - Retractable Coils , Fibered Platinum 0.035 Pushable Coil With Vortx Shape , Fibered Platinum 0.035 Pushable Coil With 2D Helical Shape , Fibered Platinum 0.035 Pushable Coil With Multi Loop Shape , Fibered Platinum 0.018 Pushable Coil With Vortx Shape , Fibered Platinum 0.018 Pushable Coil With Vortx Diamond Shape , Fibered Platinum 0.018 Pushable Coil With Multi Loop Shape , Fibered Platinum 0.018 Pushable Coil With Complex Helical Shape , Fibered Platinum 0.018 Pushable Coil With Figure 8 Shape , Fibered Platinum 0.018 Pushable Coil With Strait Shape , 0.014 Coronary Coils , 0.014 Coronary Coils Wkith Controlled Release , High Radial Strength 0.035 Macro-Coil - Pushable Coil With Long Fibers Ex. Mreye , High Radial Strength 0.038 Macro-Coil - Pushable Coil With Long Fibers Ex. Mreye , Platinum Fibered 0.035 Controlled Release Retractable Coil Ex. Retracta , Platinum Fibered 0.035 Controlled Release Retractable Coil Compatible With 3.0 Tesla Mri Imaging With Minimal Mr Signal Voidex. Mreye Flipper , Coil Delivery Catheter Suitable For 0.018 Coils ( Will Be Chosen To Match Manufacturer Of L1 Coils ) , Coil Pusher Wire Suitable For 0.018Coils ( Will Be Chosen To Match Manufacturer Of L1 Coils ) , Coil Delivery Catheter Suitable For 0.035 Coils ( Will Be Chosen To Match Manufacturer Of L1 Coils ) , Coil Pusher Wire Suitable For 0.035Coils ( Will Be Chosen To Match Manufacturer Of L1 Coils ) , Coil Delivery Catheter Suitable For 0.038 Coils ( Will Be Chosen To Match Manufacturer Of L1 Coils ) , Coil Pusher Wire Suitable For 0.038Coils ( Will Be Chosen To Match Manufacturer Of L1 Coils ) , Pva Particles Of Various Diameters ( Approximately 300-500 Microns ) , Pva Particles Of Various Diameters ( Approximately 700 Microns ) , Pva Particles Of Various Diameters ( Approximately 1000 Microns ) , Pva Particles Of Various Diameters ( Approximately 1200Microns ) , Gelfoam Embolization Bar , Valvuloplasty / Coarctoplasty / Ivc Angioplasty / Septostomy Related Equipments And Other Large Diameter Balloons , 20 Mmx 40Mm Ivc Angioplasty Catheter , Percutaneous Valvuloplasty Balloon Catheter For Neonate / Pediatric Use Of Different Sizes 0.014 Compatible , Percutaneous Valvuloplasty Balloon Catheter For Neonate / Pediatric Use Of Different Sizes 0.018 Compatible , Stainless Steel Stents Suitable For Rvot Stenting And Compatible With 0.018 Wire , Stainless Steel Stents Suitable For Rvot Stenting And Compatible With 0.035 Wire , Percutaneous Aortic / Pulmonic Valvuloplasty Balloon Catheter For Adult Use Of Different Sizes With High Rbp. , Percutaneous Aortic Valvuloplasty Balloon Catheter For Adult Use Of Different Sizes With High Rbp And Rapid Inflation And Deflation. , Inoue Or Equivalent Balloons For Mitral Valvuloplasty In Various Sizes With Complete Accessory Kit Including Dilator, Spring Wire, Stylet, Calipers Etc , Inoue Or Equivalent Balloons For Mitral Valvuloplasty In Various Sizes , Ptmc Accessory - Caliper For Balloon Calibration , Ptmc Accessory - Dilator For Septal Dilatation For Ptmc / Bmv , Ptmc Accessory - Spring Wire For Ptmc / Bmv , Ptmc Accessory - Calibrated Inflation Syringe For Various Inoue Type Balloon Sizes , Ptmc Accessory - Stylet Or J Shaped Lv Entry Wire During Ptmc / Bmv. , Percutaneous Transluminal Dilation Balloon With Markers For Coarctation Of Aorta With High Rbp All Sizes And Various Lengths. , Coda Aortic Balloon , Balloon In Balloon For Use In Coarctation Of Aorta With High Rbp , Covered Stent For Use In Coarctation Of Aorta , Stent For Use In Coarctation Of Aorta , Non Mounted Stents For Coarctation Of Aorta Length 20-50 Mm Various Sizes Upto 25 Mm Made Of Tempered Platinum - Iridium Wire Or Such Material. , Balloon Pre-Mounted Stents For Coarctation Of Aorta Length 30-50 Mm Various Sizes Upto 25 Mm Made Of Tempered Platinum - Iridium Wire Or Such Material , Atrial Septostomy Catheter Dual Lumen Shaft, Radio Opaque Catheter Body, Marker In The Balloon Positioning, 30-45 Angulated Tip. , Pacing Devices / Icds And Related Equipments , Single Chamber Pacemaker With Rate Response ( Ssir Fully Automatic With Advanced Features And Automatic Polarity Switching, Dual Zone Rate Response With Rate Profile Optimization, Supplied As Set With One Lead; Tined ( 25% ) And Active Fixation Leads ( 75% ) For Ventricular Chamber; Peel Away Sheath Compatible With Supplied Leads ) . Mri Compatibility Up To 1.5 Tesla For Pacemaker System. , Dual Chamber Pacemaker With Pacing In Ventricle Only And No Rate Response With Separate A And V Leads ( Vdd, Fully Automatic With Advanced Features, Auto Polarity And Mode Switching, Algorithm To Minimize Ventricular Pacing, Supplied As Set With Two Leads; Active Fixation Lead For Atrial Chamber And Tined ( 25% ) And Active Fixation Leads ( 75% ) For Ventricular Chamber; Two Peel Away Sheaths Compatible With Supplied Leads ) Mri Compatibility Up To 1.5 Tesla For Pacemaker System. , Dual Chamber Pacemaker With No Rate Response With Separate A And V Leads ( Ddd, Fully Automatic With Advanced Features, Auto Polarity And Mode Switching, Algorithm To Minimize Ventricular Pacing, Supplied As Set With Two Leads; Active Fixation Lead For Atrial Chamber And Tined ( 25% ) And Active Fixation Leads ( 75% ) For Ventricular Chamber; Two Peel Away Sheaths Compatible With Supplied Leads ) Mri Compatibility Up To 1.5 Tesla For Pacemaker System. , Dual Chamber Pacemaker With Rate Response With Separate A And V Leads ( Dddr, Fully Automatic With Advanced Features, Dual Zone Rate Response With Rate Profile Optimization, Auto Polarity And Mode Switching, Algorithm To Minimize Ventricular Pacing, Supplied With Two Leads; Active Fixation Lead For Atrial Chamber And Tined ( 25% ) And Active Fixation Leads ( 75% ) For Ventricular Chamber; Two Peel Away Sheaths Compatible With Supplied Leads ) Mri Compatibility Up To 1.5 Tesla For Pacemaker System. , Single Chamber Pacemaker With Rate Response ( Ssir Fully Automatic With Advanced Features And Automatic Polarity Switching, Dual Zone Rate Response With Rate Profile Optimization, Supplied As Set With One Lead; Tined ( 25% ) And Active Fixation Leads ( 75% ) For Ventricular Chamber; Peel Away Sheath Compatible With Supplied Leads ) . Mri Compatibility Up To 3.0 Tesla For Pacemaker System. , Dual Chamber Pacemaker System Dddr ( Mri Compatible Upto 3.0 Tesla ) With Rate Response With Separate A And V Leads ( Dddr, Fully Automatic With Advanced Features, Dual Zone Rate Response With Rate Profile Optimization, Auto Polarity And Mode Switching, Algorithm To Minimize Ventricular Pacing, Supplied With Two Leads; Active Fixation Lead For Atrial Chamber And Tined ( 25% ) And Active Fixation Leads ( 75% ) For Ventricular Chamber; Two Peel Away Sheaths Compatible With Supplied Leads ) Also Cable For Psa To Be Included. , Single Chamber Pacemaker With Rate Response ( Ssir Fully Automatic With Advanced Features And Automatic Polarity Switching, Dual Zone Rate Response With Rate Profile Optimization, Algorithm To Minimize Ventricular Pacing; Device Only To Be Supplied ) .Also Cable For Psa To Be Included. Mri Compatibility Up To 1.5 Tesla For Pacemaker. , Dual Chamber Pacemaker With Pacing In Ventricle Only And No Rate Response With Separate A And V Leads ( Vdd, Fully Automatic With Advanced Features, Auto Polarity And Mode Switching, Algorithm To Minimize Ventricular Pacing, Device Only To Be Supplied ) Also Cable For Psa To Be Included. Mri Compatibility Up To 1.5 Tesla For Pacemaker. , Dual Chamber Pacemaker With No Rate Response With Separate A And V Leads ( Ddd, Fully Automatic With Advanced Features, Auto Polarity And Mode Switching, Algorithm To Minimize Ventricular Pacing, Device Only To Be Supplied ) Also Cable For Psa To Be Included. Mri Compatibility Up To 1.5 Tesla For Pacemaker. , Dual Chamber Pacemaker With Rate Response With Separate A And V Leads ( Dddr, Fully Automatic With Advanced Features, Dual Zone Rate Response With Rate Profile Optimization, Auto Polarity And Mode Switching, Algorithm To Minimize Ventricular Pacing, Device Only To Be Supplied ) Also Cable For Psa To Be Included. Mri Compatibility Up To 1.5 Tesla For Pacemaker. , Dual Chamber Pacemaker ( Mri Compatible Up To 3.0 Tesla ) ) With Rate Response With Separate A And V Leads ( Dddr, Fully Automatic With Advanced Features, Dual Zone Rate Response With Rate Profile Optimization, Auto Polarity And Mode Switching, Algorithm To Minimize Ventricular Pacing, Device Only To Be Supplied ) Also Cable For Psa To Be Included. Mri Compatibility Up To 3.0 Tesla For Pacemakers. , Dual Chamber Pacemaker ( Mri Compatible Up To 3.0 Tesla ) ) With Rate Response With Separate Atrial Lead And Specialized / Dedicated His Bundle Pacing Lead And Delivery System ( Dddr, Fully Automatic With Advanced Features, Dual Zone Rate Response With Rate Profile Optimization, Auto Polarity And Mode Switching, Algorithm To Minimize Ventricular Pacing, Device Only To Be Supplied ) Also Cable For Psa To Be Included. Mri Compatibility Up To 3.0 Tesla For Pacemakers. , Single Chamber Pacemaker With Rate Response ( Ssir Fully Automatic With Advanced Features And Automatic Polarity Switching, Dual Zone Rate Response With Rate Profile Optimization, Algorithm To Minimize Ventricular Pacing; Supplied With One Lead; Tined ( 25% ) And Active Fixation Leads ( 75% ) For Ventricular Chamber; Peel Away Sheath Compatible With Supplied Leads ) With Life Time Warranty.Also Cable For Psa To Be Included. Mri Compatibility Up To 1.5 Tesla For Pacemaker System. , Dual Chamber Pacemaker ( Mri Compatible ) With Rate Response With Separate A And V Leads ( Dddr, Fully Automatic With Advanced Features, Dual Zone Rate Response With Rate Profile Optimization, Auto Polarity And Mode Switching, Algorithm To Minimize Ventricular Pacing, Supplied With Two Leads; Active Fixation Lead For Atrial Chamber And Tined ( 25% ) And Active Fixation Leads ( 75% ) For Ventricular Chamber; Two Peel Away Sheaths Compatible With Supplied Leads ) With Life Time Warranty. Also Cable For Psa To Be Included. Mri Compatibility Up To 1.5 Tesla For Pacemaker System. , Single Chamber Pacemaker With Rate Response ( Ssir Fully Automatic With Advanced Features And Automatic Polarity Switching, Dual Zone Rate Response With Rate Profile Optimization, Algorithm To Minimize Ventricular Pacing; Supplied With One Lead; Tined ( 25% ) And Active Fixation Leads ( 75% ) For Ventricular Chamber; Peel Away Sheath Compatible With Supplied Leads ) With Life Time Warranty.Also Cable For Psa To Be Included. Mri Compatibility Up To 3.0 Tesla For Pacemaker System. , Dual Chamber Pacemaker ( Mri Compatible ) With Rate Response With Separate A And V Leads ( Dddr, Fully Automatic With Advanced Features, Dual Zone Rate Response With Rate Profile Optimization, Auto Polarity And Mode Switching, Algorithm To Minimize Ventricular Pacing, Supplied With Two Leads; Active Fixation Lead For Atrial Chamber And Tined ( 25% ) And Active Fixation Leads ( 75% ) For Ventricular Chamber; Two Peel Away Sheaths Compatible With Supplied Leads ) With Life Time Warranty. Also Cable For Psa To Be Included. Mri Compatibility Up To 3.0 Tesla For Pacemaker System. , Leadless Implantable Single Chamber Pacemaker With Delivery / Implantation System , Leadless Implanable Single Chamber Pacemaker Designed To Maintain Av Synchrony Supplied With Delivery / Implantation System , Implantable Absorbable Antibacterial Envelope For Use With Implantable Ep Devices To Minimize Risk Of Infection In Device Pocker , Permanent Endocardial Pacing Lead ( Ventricular / Atrial Endocardial Bipolar, Passive Fixation With Tines ) , Steroid Eluting, Is-1 Header. , Permanent Endocardial Pacing Lead ( Ventricular / Atrial Endocardial Bipolar, Active Fixation Steroid Eluting Screw In Lead ) With Is-1 Header. , Permanent Epicardial Pacing Lead ( Ventricular / Atrial, Bipolar Fixation Using Sutures ) , Steroid Eluting, Is-1 Header Of Various Lengths. , Permanent Epicardial Pacing Lead ( Ventricular / Atrialactive Fixation Steroid Eluting Screw In Lead ) With Is-1 Header Of Various Lengths. , Defibrillator Lead With Svc And Rv Coils For Use With Icd Device -Quote For Lead Only - Df-4 Header , Peel-Away 7F Sheath For Lead Insertion , Peel-Away 9F Sheath For Lead Insertion , Biventricular Cardiac Resynchronization Device With Programmable Rv And Lv Amplitude, Pw And Pulse Configuration Independently Pacing Rv Only, Lv Only Or Biventricular;Automatic Threashold Checking Of Lv Lead; Automatic Threashold Checking Of Lv Lead; Different Lv Pacing Vectors; Biventricular Trigger For Constant Crt During Atrial Tachyarrhythmia;It Should Have Three Independent Channels; Independent Threshold Testing, Histogram And Counters. Device To Be Supplied With All Leads And Insertions Sheaths Including Cs Sheath And Cs Seeking Catheter; Also Cable For Psa To Be Included. Is-4 Connector. , Biventricular Cardiac Resynchronization Device With Programmable Rv And Lv Amplitude, Pw And Pulse Configuration Independently Pacing Rv Only, Lv Only Or Biventricular;Automatic Threashold Checking Of Lv Lead; Automatic Threashold Checking Of Lv Lead; Different Lv Pacing Vectors; Biventricular Trigger For Constant Crt During Atrial Tachyarrhythmia;It Should Have Three Independent Channels; Independent Threshold Testing, Histogram And Counters. Device Only To Be Supplied.Also Cable For Psa To Be Included. Is-4 Connector. , Biventricular Cardiac Resynchronization Device With Programmable Rv And Lv Amplitude, Pw And Pulse Configuration Independently Pacing Rv Only, Lv Only Or Biventricular;Automatic Threashold Checking Of Lv Lead; Automatic Threashold Checking Of Lv Lead; Different Lv Pacing Vectors; Biventricular Trigger For Constant Crt During Atrial Tachyarrhythmia;It Should Have Three Independent Channels; Independent Threshold Testing, Histogram And Counters. Device Only To Be Supplied.Also Cable For Psa To Be Included. Is-4 Connector. , Biventricular Cardiac Resynchronization Device With Programmable Rv And Lv Amplitude, Pw And Pulse Configuration Independently Pacing Rv Only, Lv Only Or Biventricular;Automatic Threashold Checking Of Lv Lead; Automatic Threashold Checking Of Lv Lead; Different Lv Pacing Vectors; Biventricular Trigger For Constant Crt During Atrial Tachyarrhythmia;It Should Have Three Independent Channels; Independent Threshold Testing, Histogram And Counters. Device Only To Be Supplied.Also Cable For Psa To Be Included. Is-1 Connectors. , Combo Device ( Bi-V And Icd Device ) With Independently Programmable Rv And Lv Amplitude And Pulse Width; Complete Capture Management;Atp During Charging; Wireless Telemetry; Biventricular Trigger; Algorithm To Differntiate Svt From Vt; Flexible Waveforms For Dft Management; Device To Be Supplied With All Leads And Insertion Sheaths Including Cs Sheath And Cs Seeking Catheter.Also Cable For Psa To Be Included. Is-4 And Df-4 Connectors. , Combo Device ( Bi-V And Icd Device ) With Independently Programmable Rv And Lv Amplitude And Pulse Width; Complete Capture Management;Atp During Charging; Wireless Telemetry; Biventricular Trigger; Algorithm To Differntiate Svt From Vt; Flexible Waveforms For Dft Management; Device Only To Be Supplied.Also Cable For Psa To Be Included. Is-1 And Df-1 Connectors. , Implantable Cardioverter Defibrillator: Single Chamber; Small And Physiological; Algorithm To Eliminate Over-Sensing Of R Wave, T Wave, Fractionated Qrs And Other Extraneous Signals. Morphology Based Svt Discrimination Algorithm, Atp During Charging, Wireless Telemetry, Encourage Intrinsic Conduction, More Than 30 Minutes Of Stored Egm. Device To Be Supplied With All Leads And Sheaths.Also Cable For Psa To Be Included. Df-4 Connector. Mri Compatible Up To 1.5 Tesla. , Implantable Cardioverter Defibrillator: Single Chamber; Small And Physiological; Algorithm To Eliminate Over-Sensing Of R Wave, T Wave, Fractionated Qrs And Other Extraneous Signals. Morphology Based Svt Discrimination Algorithm, Atp During Charging, Wireless Telemetry, Encourage Intrinsic Conduction, More Than 30 Minutes Of Stored Egm. Device Only To Be Supplied.Also Cable For Psa To Be Included. Df-4 Connector. Mri Compatible. , Implantable Cardioverter Defibrillator: Single Chamber; Small And Physiological; Algorithm To Eliminate Over-Sensing Of R Wave, T Wave, Fractionated Qrs And Other Extraneous Signals. Morphology Based Svt Discrimination Algorithm, Atp During Charging, Wireless Telemetry, Encourage Intrinsic Conduction, More Than 30 Minutes Of Stored Egm. Device Only To Be Supplied.Also Cable For Psa To Be Included. Df-1 Connectors. Mri Compatible. , Implantable Cardioverter Defibrillator: Dual Chamber; Small And Physiological; Algorithm To Eliminate Over-Sensing Of R Wave, T Wave, Fractionated Qrs And Other Extraneous Signals. Morphology Based Svt Discrimination Algorithm, Atp During Charging, Wireless Telemetry, Encourage Intrinsic Conduction, More Than 30 Minutes Of Stored Egm. Device To Be Supplied With All Leads And Sheaths.Also Cable For Psa To Be Included. Df-4 Connector. Mri Compatible. , Implantable Cardioverter Defibrillator: Dual Chamber; Small And Physiological; Algorithm To Eliminate Over-Sensing Of R Wave, T Wave, Fractionated Qrs And Other Extraneous Signals. Morphology Based Svt Discrimination Algorithm, Atp During Charging, Wireless Telemetry, Encourage Intrinsic Conduction, More Than 30 Minutes Of Stored Egm. Device Only To Be Supplied.Also Cable For Psa To Be Included. Df-4 Connector. Mri Compatible. , Implantable Cardioverter Defibrillator: Dual Chamber; Small And Physiological; Algorithm To Eliminate Over-Sensing Of R Wave, T Wave, Fractionated Qrs And Other Extraneous Signals. Morphology Based Svt Discrimination Algorithm, Atp During Charging, Wireless Telemetry, Encourage Intrinsic Conduction, More Than 30 Minutes Of Stored Egm. Device Only To Be Supplied.Also Cable For Psa To Be Included. Df-1 Connector. Mri Compatible. , Implantable Loop Recorder , Implantable Loop Recorder With Bluetooth Connectivity , 8 French Fixed Curve Sheath With Different Curves For Ep Studies / Rfa , 5 French Fixed Curve Quadripolar Catheter With 2-5-2 Interelectrode Spacing With Matching Connector , 6 French Fixed Curve Quadripolar With 2-5-2 / 5-5-5 Interelectrode Spacing. , 6 French Deflectable Quadripolar Catheter With 2-5-2 Interelectrode Spacing And Matching Connector , 6 French Deflectable Decapolar Catheter With 2-5-2 Interelectrode Spacing And Matching Connector , 6 Or 7 French Deflectable Duodecapolar Catheters ( Halo ) With Matching Connectors , Long Deflectable Sheath With Hemostatic Valve, Side Port, Atraumatic Tip, Braided Shaft, Uni- Or Bidirectional Steerability, Availability In Small, Medium Or Large Curves, Minimum Inner Diameter Or 7F, Minimum Length Of 65 Cms , 7 French Quadripolar Radiofrequency Ablation Catheter With A 4 Mm Tip, Unidirectional Deflection, Availability In Small, Medium And Large Curves. Should Be Compatible With Ibi Rf Generators And Suitable Connecting Cable Should Be Provided. , 7 French Quadripolar Radiofrequency Ablation Catheter With A 4 Mm Tip, Bidirectional Deflection, Availability In Small, Medium And Large Curves. Should Be Compatible With Ibi Rf Generators And Suitable Connecting Cable Should Be Provided , 7 French Quadripolar Radiofrequency Ablation Catheter With A 8 Mm Tip, Unidirectional Deflection, Availability In Small, Medium And Large Curves. Should Be Compatible With Ibi Rf Generators And Suitable Connecting Cable Should Be Provided , 7 French Quadripolar Radiofrequency Ablation Catheter With Irrigated Tip, Uni- Or Bi-Directional Deflection And Availability In Medium And Large Curves. Should Be Compatible With Ibi Rf Generators And Suitable Connecting Cable Should Be Provided. , Surface Electrode Kit For Navigation Purpose Which Is Compatible With Ensite Velocity 3D Mapping System , Structural Interventional Implants And Accessories , Pda Duct Occluder, Usfda Approved Diameter Of All Sizes - Device Only , Pda Duct Occluder, Usfda Approved Small Diameter Compatible With 4F Delivery System - Device Only , Pda Duct Occluder, Usfda Approved Diameter Of All Sizes - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Pda Duct Occluder, Usfda Approved Small Diameter Compatible With 4F Delivery System - Sdevice With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Pda Duct Occluder Double Disk, Usfda Approved Diameter Of All Sizes - Device Only , Pda Duct Occluder Double Disk, Usfda Approved Diameter Of All Sizes - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Pda Duct Occluder, Ce Marked Diameter Of All Sizes - Device Only , Pda Duct Occluder, Ce Marked Small Diameter Compatible With 4F Delivery System - Device Only , Pda Duct Occluder, Ce Marked Diameter Of All Sizes - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Pda Duct Occluder, Ce Marked Small Diameter Compatible With 4F Delivery System - Sdevice With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Pda Duct Occluder ( Type Ii And As ) , Dcgi Approved Diameter Of All Sizes - Device Only , Pda Duct Occluder ( Type Ii And As ) , Dcgi Approved Diameter Of All Sizes - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Muscular Vsd Closure Device, Usfda Approved- Device Only , Muscular Vsd Closure Device, Usfda Approved- Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Muscular Vsd Closure Device, Ce Marked- Device Only , Muscular Vsd Closure Device, Ce Marked- Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Muscular Vsd Closure Device, Dcgi Approved- Device Only , Muscular Vsd Closure Device, Dcgi Approved- Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Muscular Vsd Closure Device ( Post-Infarction ) , Usfda Approved - Device Only , Muscular Vsd Closure Device ( Post-Infarction ) , Usfda Approved - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Muscular Vsd Closure Device ( Post-Infarction ) , Ce Marked - Device Only , Muscular Vsd Closure Device ( Post-Infarction ) , Ce Marked - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Muscular Vsd Closure Device ( Post-Infarction ) , Dcgi Approved - Device Only , Muscular Vsd Closure Device ( Post-Infarction ) , Dcgi Approved - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Peri-Membranous Vsd Closure Device, Usfda Approved - Device Only. , Peri-Membranous Vsd Closure Device, Usfda Approved - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Peri-Membranous Vsd Closure Device, Ce Marked Approved - Device Only. , Peri-Membranous Vsd Closure Device, Ce Marked Approved - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Peri-Membranous Vsd Closure Device, Dcgi Approved Approved - Device Only. , Peri-Membranous Vsd Closure Device, Dcgi Approved Approved - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Asd Closure Device, Usfda Approved - Device Only. , Asd Closure Device With Fenestration, Usfda Approved - Device Only. , Asd Closure Device, Usfda Approved - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Asd Closure Device, Ce Marked Approved - Device Only. , Asd Closure Device, Ce Marked Approved - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Asd Closure Device, Dcgi Approved Approved - Device Only. , Asd Closure Device, Dcgi Approved Approved - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Pfo Closure Device, Usfda Approved - Device Only. , Pfo Closure Device, Usfda Approved- Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Pfo Closure Device, Ce Approved - Device Only. , Pfo Closure Device, Ce Marked Approved - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Pfo Closure Device, Dcgi Approved Approved - Device Only. , Pfo Closure Device, Dcgi Approved Approved - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Cribriform Asd Closure Device, Usfda Approved - Device Only. , Cribriform Asd Closure Device, Usfda Approved - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Cribriform Asd Closure Device, Ce Marked Approved - Device Only. , Cribriform Asd Closure Device, Ce Marked Approved - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Cribriform Asd Closure Device, Dcgi Approved Approved - Device Only. , Cribriform Asd Closure Device, Dcgi Approved Approved - Device With All The Accessories Like Delivery Sheath, Loader, Deploying Cable Etc. , Amplatzer Vascular Plug 1;All Available Sizes With Delivery System , Amplatzer Vascular Plug 2;All Available Sizes With Delivery System , Amplatzer Vascular Plug 3;All Available Sizes With Delivery System , Amplatzer Vascular Plug 4;All Available Sizes With Delivery System , Amplatzer Sizing Plate For Device Closure , Asd Sizing Balloon, Amplatzer Type Of Various Sizes , Asd Sizing Balloon, Meditech Type Of Various Sizes. , Sheath For Retrieval Of Asd And Other Similar Devices. , La Appendage Occlusion Device - Usfda Approved Supplied With All Accessories , La Appendage Occlusion Device - Ce Marked Supplied With All Accessories , La Appendage Occlusion Device With Stabilizing Wires- Usfda Approved Supplied With All Accessories , La Appendage Occlusion Device With Stabilizing Wires - Ce Marked Supplied With All Accessories , Peripheral Stents Including Covered Stents , Balloon Mounted Peripheral Stent Suited For Renal Artery Use ( 4-7 Mm Dia ) With Cobalt Chromium Struts With 0.014- 0.035 Wire Compatible With Lenghts Of 15-18Mm. , Balloon Mounted Peripheral Stent Suited For Renal Artery Use ( 4-7 Mm Dia ) With Stainless Steel Strutswith 0.014- 0.035 Wire Compatible With Lenghts Of 15-18Mm. , Balloon Mounted Peripheral Stent Suited For Iliac Artery Use. Diameter 7-10 Mmand Stent Length 12-57Mm With 6-8 Sheath Compatiblewith Cobalt Chromium Struts For Use Over 0.035 Wire. , Balloon Mounted Peripheral Stent Suited For Iliac Artery Use. Diameter 5-10 Mmand Stent Length 12- 59Mm With 6-8 Sheath Compatiblewith Cobalt Chromium Struts For Use Over 0.035 Wire. , Balloon Mounted Peripheral Stent Suited For Subclavian Artery Use With Cobalt Chromium Struts Over 0.035 Wire Of Various Diameter And Lenghts. , Self Expanding Stent Of Nitinol With 0.014 Wire Compatibility With2-4Mm Diameter And 50-200 Mm Length, 6F Sheath Compatible , Self Expanding Stent Of Nitinol With 0.035 Wire Compatibility With8-12Mm Diameter And 100 , 120 Mm Length, 6F Sheath Compatible Suited For Biliary Stenting Use , Balloon Explandable Stent With 0.035 Wire Compatibility With8-12Mm Diameter And 40-120 Mm Length, 6F Sheath Compatible Suited For Biliary Stenting Use , Self Expanding Stent Of Nitinol With 0.014-0.035 Wire Compatibility With Diameter Of 5-7Mm And Lengths Of 40-170 Mm Suited For Sfa And Popliteal Use , Self Expanding Stent Of Nitinol With 0.035 Wire Compatibility With Maximal Stent Lengths Of Minimum 100 Mm And Suited For Sfa Use , Self Expanding Stent Of Nitinol With 0.035 Wire Compatibility With Maximal Stent Lengths Of Minimum 150 Mm And Suited For Sfa Use , Self Expanding Stent Of Nitinol With 0.035 Wire Compatibility With Maximal Stent Lengths Of Minimum 200 Mm And Suited For Sfa Use , Self Expanding Stent Of Nitinol With 0.035 Wire Compatibility With Maximal Stent Lengths Of Minimum 250 Mm And Suited For Sfa Use , Self Expanding Stent Of Nitinol With 0.035 Wire Compatibility With Maximal Stent Lengths Of Minimum 100 Mm And Suited For Popliteal Artery Use , Self Expanding Stent Of Nitinol With 0.035 Wire Compatibility With Maximal Stent Lengths Of Minimum 150 Mm And Suited For Popliteal Artery Use , Self Expanding Stent Of Nitinol With 0.035 Wire Compatibility With Maximal Stent Lengths Of Minimum 200 Mm And Suited For Popliteal Artery Use , Nitinol Vasculomimetic Implant For Sfa And Popliteal Use With Compression Resistance And Diameters Of 4-7 Mm And Lengths 40-200 Mm , Self Expanding Stent Of Nitinol With 0.035 Wire Compatibility With Maximal Stent Lengths Of Minimum 120 Mm And Suited For Iliac Use , Endovascular Nitinol Stent Graft 6-10F Sheath Compatible With Diameter Of5-13.5Mm With Length 20-120 Mm On 0.035 Guidewire , Endovascular Stent Graft 5-9 F Sheath Compatible With Diameter Of6 Mm With Length 20-100 Mm On 0.035 Guidewire , Endovascular Stent Graft 5-9 F Sheath Compatible With Diameter Of8 Mmwith Length 20-100 Mm On 0.035 Guidewire , Endovascular Stent Graft 5-9 F Sheath Compatible With Diameter Of 10 Mmwith Length 40-80Mm, 100 And 120 Mm ( For Tips ) On 0.035 Guidewire , Carotid Stents / Stent Grafts / Ivc Filters , Carotid Stent - Self Expanding With Straight Open Cell Design With Stabilizer Incorporated In Deployment Mechanism For Accurate Placement , Carotid Stent - Self Expanding With Tapered Open Cell Design With Stabilizer Incorporated In Deployment Mechanism For Accurate Placement , Carotid Stent - Self Expanding With Staright Open Cell Design With Micronet Mesh Stabilizer Incorporated In Deployment Mechanism For Accurate Placement Ex C Guard , Carotid Stent - Self Expanding With Straight Closed Cell Design With Stabilizer Incorporated In Deployment Mechanism For Accurate Placement , Carotid Stent - Self Expanding With Tapered Closed Cell Design With Stabilizer Incorporated In Deployment Mechanism For Accurate Placement , Ivc Filter - Retrievable - For Jugular Approach Retrievability Demonstrated Up To At Least One Year , Ivc Filter - Retrievable - For Femoral Approachretrievability Demonstrated Up To At Least One Year , Stent Graft Balloon Catheter , Aaa Stent Graft System - Aaa Graft And Unilimb Extension , Aaa Stent Graft System - Abdominal Tube , Aaa Stent Graft System - Plug For Iliac Occlusion , Aaa Stent Graft System - Limb Extension , Aaa Stent Graft System - Aaa Graft And Unilimb Extension With Supra-Renal Fixation , Aaa Stent Graft System With Magnet Accelerated Cannulationto Facilitate Fast And Easy Cannulation. , Thoracic Stent Graft System , Thoracic Stent Graft Cuff Or Extension , Thoracic Stent Graft System With Length Ranging From 100-250Mm, Nitinol Precurved Inner Catheter To Support The Natural Curature Of The Aorta , V-Patch To Allow For Stent Graft Eexpansion Towards The Inner Curve For A Current Apposition And To Avoid Gaps , Non Vascular Ir Procedure Hardware , 8F Pcn Set With Dilators With Catheter Length Of 30 Cm With 18Gx16 Cm Pucture Needle With 0.035 Guide Wire , 10 F Pcn Set With Dilators With Catheter Length Of 30 Cm With 18Gx16 Cm Pucture Needle With 0.058 Guide Wire , 8.3 F Ring Biliary Duct Drainage Catheter With Catheter Length 50 Cm Which Accepts 0.035 Guide Wire , 10.0Ring Biliary Duct Drainage Catheter With Catheter Length 50 Cm Which Accepts 0.035 Guide Wire , Abscess Drainage Set 20, 24 And 28 F With Dilators With 0.038 / 0.035 Guide Wire With Acess Needle With Catheter Length Of 40 Cm Ex. Cook Thal Set , 8F Pigtail Catheter 30 Cm Length With Trocar , 8F Pigtail Catheter 30 Cm Length Without Trocar , 10F Pigtail Catheter 30 Cm Length With Trocar , 10F Pigtail Catheter 30 Cm Without Trocar , 12F Pigtail Catheter 30 Cm Length With Trocar , 12 F Pigtail Catheter 30 Cm Length Without Trocar , Mallecots Drainage Catheter10-20 F Without Trocar 30 Cm In Length , Mallecots Drainage Catheter10-20 F Without Trocar 30 Cm In Length , Transjugular Liver Acess And Biopsy Set With Needle Length 60 Cm, 18G, 2 Cm Ex. Cook Liver Acess And Biopsy Set , Transjugular Liver Acess And ( Rtps ) Set 10 And 30-40 Cm In The Length , Rösch-Uchida Transjugular Liver Access Set ( Rups-100 ) With10f Introducer Sheath With Stiffining Cannula And Dilators , Directional Atherectomy Deivce ( Active Segment Length 40-75 Mm ) For Vessel Diameter 2-4 Mm, 6 F Sheath Compatible With Working Length 135-150 Cm. For Vessel Diameter3.5--7 Mm, 6 F Sheath Compatible With Working Length 135-150 Cm. , Re Entry Device , Reentry Catheter Of 80, 120Cm Length With 6F Sheath Compatibility With 0.014 Guidewire Ex.Out Back Cordis. , Re Entry Device With Balloon Position Catheter ( 70 And 100 Cm ) With Lancet Catheter Length 79 And 109 Cm With 6F Sheath Compatibility With 0.014 Guidewire Ex-Re Enter Catheter Medtronic. , Contrast Agents / Liquid Embolic Agents / Equipment For Tumour Rfa / Chemotherapeutic Agents For Intrarterial Therapy / Thrombin For Local Use , Radiocontrast Iodinated For Coronary And Peripheral Angiography In 200 / 250 / 500 Ml Vials , Radiocontrast Iodinated For Coronary And Peripheral Angiography Safe For Use With Renal Insufficiency 100 / 200 / 250 Ml Vials , Sodium Tetradecylsulphate ( Setrol ) 2 X 2 Ml Pack , Glue ( N-Butyl Cynoacraylate ) 1 Ml Vial , Lipidol Ultrafluid 10 Ml Vial , 50 Mg Lypholised Epirubicinvialfor Iv Use , 10 Mg Lypholised Epirubicinvial For Iv Use , Thrombin 1000, 2500 Iu With Calcium Chloride Vial For Pseudoaneurysm Embolization , Rfa Electrode ( With Rfamachine Rental Charges Included ) : 2-3 Cm Ablation With 15 Cm Length , Rfa Electrode ( With Rfamachine Rental Charges Included ) : 3-5 Cm Ablation With 15 Cm Length , Rfa Electrode ( With Rfamachine Rental Charges Included ) : 2 Cm Ablation 15 Cm Length For Osteoid Osteoma With Delivery System , Microwave Cermaic Antena Syatem For Ablation Of Hcc E ( With Machine Rental Charges Included ) 2-3Cm Ablation , Microwave Cermaic Antena Syatem For Ablation Of Hcc ( With Machine Rental Charges Included ) 3-5Cm Ablation , Radiation Protection , Disposable Non Fenestrated Lead Free Absorbable Sterile Barrier Pad For Protection During Fluoroscopy For Interventional Procedures With A Minumum Thickness Of 0.25 Mm Lead Equivalence And Usfda Approved , Disposable Non Fenestrated Lead Free Absorbable Head Cap For Protection During Fluoroscopy For Interventional Procedures With A Minumum Thickness Of 0.25 Mm Lead Equivalence And Usfda Approved , Lead Vest And Skirt For Radiation Protection In Cardiac Catheterization Laboratory With ) .5 Mm Equivalent Lead Protection In Front And 0.25Mm Lead Protection At Back With Lightest Material Available From Supplier Company; Heavy Materials Will Be Disqualified. Washable And Durable Materials Needed. Small Size. , Lead Vest And Skirt For Radiation Protection In Cardiac Catheterization Laboratory With ) .5 Mm Equivalent Lead Protection In Front And 0.25Mm Lead Protection At Back With Lightest Material Available From Supplier Company; Heavy Materials Will Be Disqualified. Washable And Durable Materials Needed. Medium Size. , Lead Vest And Skirt For Radiation Protection In Cardiac Catheterization Laboratory With ) .5 Mm Equivalent Lead Protection In Front And 0.25Mm Lead Protection At Back With Lightest Material Available From Supplier Company; Heavy Materials Will Be Disqualified. Washable And Durable Materials Needed. Large Size. , Lead Collar For Radiation Protection In Cardiac Catheterization Laboratory With ) .35 Mm Or More Equivalent Lead Protection With Lightest Material Available From Supplier Company; Heavy Materials Will Be Disqualified. Washable And Durable Materials Needed. Large Size. , Lead Cap For Radiation Protection In Cardiac Catheterization Laboratory With ) .25 Mm Or More Equivalent Lead Protection With Lightest Material Available From Supplier Company; Heavy Materials Will Be Disqualified. Washable And Durable Materials Needed. Large Size. , Lead Single Piece Gown For Radiation Protectionin Cardiac Catherization Laboratory With .5Mm Equivalent Lead Protection In Front And 0.25Mm Lead Protection At Back With Lightest Material Available From Supplier Compnay , Heavy Materials Will Be Disqualified . Washable And Durable Materials Needed Small Size. , Lead Single Piece Gown For Radiation Protectionin Cardiac Catherization Laboratory With .5Mm Equivalent Lead Protection In Front And 0.25Mm Lead Protection At Back With Lightest Material Available From Supplier Compnay , Heavy Materials Will Be Disqualified . Washable And Durable Materials Needed Medium Size. , Lead Single Piece Gown For Radiation Protectionin Cardiac Catherization Laboratory With .5Mm Equivalent Lead Protection In Front And 0.25Mm Lead Protection At Back With Lightest Material Available From Supplier Compnay , Heavy Materials Will Be Disqualified . Washable And Durable Materials Needed Largesize.