Sub-Tender Of E-Tender 510544- Jamnagar Ga- Dhrol Town Connectivity From Padadhari Cng-1 Steel Laying, 5-50Km, Allsoil, 6.4Mm, X52, 6 Pipeline Laying / Installation_All Type Of Soil_Length > 5, 000 Meters Up To 50, 000 Meters_Size: 6 Nb ( 168.3 Mm Od ) , Wt 6.4 Mm, Api 5L ( Psl-2 ) Gr. X52 3Lpe Coated 2 Steel Laying, 5-50Km, Allsoil, 6.4Mm, X52, 4 Pipeline Laying / Installation_All Type Of Soil_Length > 5, 000 Meters Up To 50, 000 Meters_Size: 4 Nb ( 114.3 Mm Od ) , Wt 6.4 Mm, Api 5L ( Psl-2 ) Gr. X52 3Lpe Coated 3 Steel, Hdd, Along, Nonrocky, 6.4Mm, X52, 6 Pipeline Laying / Installation By Hdd Method_Along Route_All Soil Other Than Rocky Strata_Size: 168.3 Mm ( 6 ) Wt 6.4 Mm Api 5L ( Psl-2 ) Gr. X52 3Lpe Coated 4 Steel, Hdd, Along, Rocky, 6.4Mm, X52, 6 Pipeline Laying / Installation By Hdd Method_Along Route ( Parallel ) _Rocky Strata_Size: 168.3 Mm ( 6 ) Wt 6.4 Mm Api 5L ( Psl-2 ) Gr. X52 3Lpe Coated 5 Hdd, Crossing, Uncased, Rocky, 6.4Mm, 6 Pipeline Laying / Installation By Hdd Method_Across Route ( Crossing ) _Without Casing Pipe_Rocky Strata_Size: 168.3 ( 6” ) Wt 6.4 Mm Api 5L ( Psl-2 ) Gr. X52 3Lpe Coated 6 Hdd, Crossing, Uncased, Rocky, 6.4Mm, 4 Pipeline Laying / Installation By Hdd Method_Across Route ( Crossing ) _Without Casing Pipe_Rocky Strata_Size: 168.3 ( 4” ) Wt 6.4 Mm Api 5L ( Psl-2 ) Gr. X52 3Lpe Coated 7 Boring, Rocky, Casing12, Carr.6, 6.4Mm Pipeline Laying / Installation By Thrust Boring / Drilling_Crossing_With Casing Pipe_Rocky Strata_Carrier Size: 168.3 ( 6 ) Wt 6.4 Mm Api 5L ( Psl-2 ) Gr. X52 3Lpe Coated_Casing Size: 12” 8 Supply, Casing Pipe, Wt 9.5Mm, 12 Supply Of Steel Casing Pipe_12 Nb X 9.5 Mm Thick - Api 5L Gr. B / Is3589 Gr. Fe 410 Or Fe 440 Astm A 106 Gr. B / Astm A 333 Gr. 6 X 9.5 Mm Wt Including Transportation To Site As Directed By Eic 9 Fabrication, Installation, Steel, Sch40 Piping Construction / Installation For Above Ground / Under Ground Facility_Carbon Steel Piping_Sch 40_Inch Diameter 10 Fabrication, Installation, Steel, Sch80 Piping Construction / Installation For Above Ground / Under Ground Facility_Carbon Steel Piping_Sch 80_Inch Diameter 11 Fabrication, Installation, Steel, Sch160 Piping Construction / Installation For Above Ground / Under Ground Facility_Carbon Steel Piping_Sch 160_Inch Diameter 12 Civil Work, A / G, U / G Prs, Upto 5000 Scmh Civil Works For Above Ground / Under Ground Installation Of Drs / Prs / Cprs 13 Chamber, Piping, Install, Valve, 6 Installation / Construction Of Isolating / Sectionalizing / Tap Off Valve Including Construction Of Rcc Valve Chamber_6 Size_All Pressure Class Pipeline Laying By Hdd Method Along Route ( Parallel Hdd ) Pipeline Laying By Hdd Method Across Route ( Crossing Hdd ) Pipeline Installation By Thrust Boring ( Crossing ) Supply Of Casing Pipe Above Ground Piping Installation Installation Of Pressure Reduction Station Installation Of Valves 14 Chamber, Piping, Install, Valve, 4 Installation / Construction Of Isolating / Sectionalizing / Tap Off Valve Including Construction Of Rcc Valve Chamber_4 Size_All Pressure Class 15 End Connectivity, With Pipe / Valve, 6 Pipeline End Connectivity With Exisitng Pipeline Or Exisitng Tap Off Valve_Pipeline Size Nb Wt 6.4 Mm Or Tap Off Valve 6 Nb Including Pit Excavation, Valve Greasing, Welding, N2 Purging, Ndt, Coating, Backfilling, Supply Of Manpower And Machinary Etc. 16 End Connectivity, With Shutdown, Pipe, 6 Pipeline End Connectivity With Exisitng Pipeline With Shutdown Activity In Exisitng Pipeline_Pipeline Size 6 Nb Including Pit Excavation, Valve Greasing, Welding, N2 Purging, Ndt, Coating, Backfilling, Supply Of Manpower And Machinary Etc. 17 S&I, Route Marker, Rcc Supply / Installation Of Permanent Markers_Rcc Route Marker 18 S&I, Route Marker, Km Post Supply / Installation Of Permanent Markers_Route Marker Kilometer Post 19 S&I, Warning Marker, W / Post, Foundation Supply / Installation Of Permanent Markers_Warning Marker With Post & Foundation 20 S&I, Direction Marker, Rcc Supply / Installation Of Permanent Markers_Direction Marker 21 Pre-Comm, Preservation, Commissioning, W / N2 Pre-Commissioning, Preservation & Commissioning Of Pipeline With Nitrogen 22 S&I, Tcp, Type A, Potential Measurement Temporary Cathodic Protection ( Tcp ) _Type A Test Station For Potential Measurement 23 S&I, Tcp, Type B, Current Measurement Temporary Cathodic Protection ( Tcp ) _Type B Test Station For Current Measurement 24 S&I, Tcp, Type C, Foreign Pipeline Crossing Temporary Cathodic Protection ( Tcp ) _Type C Test Station For Foreign Pipeline Crossing 25 S&I, Tcp, Type D, Cased Crossing Temporary Cathodic Protection ( Tcp ) _Type D Test Station For Cased Crossing 26 S&I, Tcp, Type E, Ht Line Crossing Temporary Cathodic Protection ( Tcp ) _Type H Test Station For Ht Line Crossing 27 S&I, Tcp, Type F, Insulating Joint Temporary Cathodic Protection ( Tcp ) _Type E Test Station For Insulating Joints 28 S&I, Tcp, Type G, Polarization Coupon Temporary Cathodic Protection ( Tcp ) _Type G Test Station For Polarization Coupon Location 29 S&I, Tcp, Pre Packed, Mg Anode, 10Kg Temporary Cathodic Protection ( Tcp ) _Supply & Installation Of Pre-Packed Mg- Anode ( 10 Kg ) 30 S&I, Tcp, Pre Packed, Mg Anode, Casing Temporary Cathodic Protection ( Tcp ) _Supply & Installation Of Pre-Packed Mg For Protection Of External Surface Of Casing Pipe Under Railway Crossings For ( 40+1 ) Years As Per Rdso Norms 31 S&I, Tcp, Mitigate Ac Interference, Ht Locn Temporary Cathodic Protection ( Tcp ) _Ac Interference Mitigation At Ht Location 32 Monitoring, Tcp System, One Year Temporary Cathodic Protection ( Tcp ) _Monitoring The Installed [ Tcp ] System For 1 Year 33 S&I, Tcp, Pre Packed, Zn, Anode, 10Kg Temporary Cathodic Protection ( Tcp ) _Supply & Installation Of Pre-Packed Zn -Anode ( 10 Kg ) Pipeline End Connection Installation Of Pipeline Markers Pre Commissioning & Commissioning Temporary Cathodic Protection System