}

Rate Contract For Supply Of Disposable And Chemicals For Nephrology Hemoconcentrate Part A & B - — - A The Constituents Of The Hemoconcentrate Are As Follows •Part-A ( Aqueous ) -Sodum Chlonde 180-170G11. Potassium Chloride 5-55G / L. Caccium Chlorid, Jodhpur-Rajasthan

Medical College has published Rate Contract For Supply Of Disposable And Chemicals For Nephrology Hemoconcentrate Part A & B - — - A The Constituents Of The Hemoconcentrate Are As Follows •Part-A ( Aqueous ) -Sodum Chlonde 180-170G11. Potassium Chloride 5-55G / L. Caccium Chlorid. Submission Date for this Tender is 30-03-2022. Coats and Jackets Tenders in Jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

31408057
Corrigendum : Rate Contract For Supply Of Disposable And Chemicals For Nephrology Hemoconcentrate Part A & B - — - A The Constituents Of The Hemoconcentrate Are As Follows •Part-A ( Aqueous ) -Sodum Chlonde 180-170G11. Potassium Chloride 5-55G / L. Caccium Chlorid
Open Tender
Indian
Rajasthan
Jodhpur
30-03-2022

Tender Details

Rate Contract For Supply Of Disposable And Chemicals For Nephrology Hemoconcentrate Part A & B - — - A The Constituents Of The Hemoconcentrate Are As Follows •Part-A ( Aqueous ) -Sodum Chlonde 180-170G11. Potassium Chloride 5-55G / L. Caccium Chloride 85- 9911, Magnesum Chloride 5-550G11 Glaclal Acetic Acdd 8-9Git And Os Purified Water ( When Diluted As 1 34 ) Sodium 75-8S Mmolil. Potassium: 0-2Mmoul. Calcium-1 70-1 75Mmovt. Magnesum 0.75- 1Mmowt. Chloride 85-9Ommoul. Acetate 3.5- 4 5Mmolil Part B. Each Powder Packet Weighing 800-9O0gm Containing Sodium Chlonde:200-300Gm, Sodium Bicarbonate 500-650Gm Which Provides After Dissolving Sodium 55-60 Mmoul, Chloride 20 25Mmout. Bicarbonate 30-40 Mmowl. ___E 2. Artero- Venous Fistula Needle One Pre-Sterlized Set Each Wimh A Pair Of Needles, 16 Gauze Needle With Back Eye And Length 25-30Mm With Fixed Wings With Luer Lock In The Attached Blood Tubnng Of Length 25- 30Cm _ 3. Dialyzer Singl Use Dlalyzer For Hermodialysis Of Adult Patients Having Synthetic Hollow Fibre Of Polysulfone, Stenlized With Non Ethyeene Oxide Method It Should Be Abee To Bear Blood Flow Of Minimum 20Omlimin And Diatysate Flow Rate Of Soomllmin With Surface Area- 1 3-1 4M ( Requirement Oo / Month ) 4. T D, Alyzer. Dialyzer For Hemodialysis Of Adult Patients Which Should Be Presterlized With Non Ethylene Oxide Method With And Reusable Hawing Synthetic Hollow Fibre Of Potysulfone Able To Bear Blood Flow Of Minimum 200Mlimin And Diatysate Flow Rate Of 5O0mlimin With Surtaec Arca-L.6-L.7 M’ ( Requirement: 40 Month ) Which Should Be Able To Be Rinsed Emfectively For Rcuscposi Hemodialysis. 5 tAterosenoisfhnefh should be supplied with blood — tubing to be attached to the dialyzer during dialysis. The length of pee sterilized latex free medical grade tubing should be 3540cm with capacity of priming volume approximately l45-155ml with arterial chamber, venous chamber with respective arterial and venous liter locks and injection ports in the tubing and ends of the tubing fitted - with suitable connector% to the access and dialyzer. Pediatric dialyzer: The pediatric dialyzer should be pre sterilited by non ethylene oxide method and made of synthetic Polysulfone hollow fibre with surface area 0.6 m2 (requirement: 25/year). The dialyzer and arteriovenous __-__ blood line of same manufacturer would be preferred. 7. Pediatric dialyzer: The pediatric dialyzer should be pre sterilized by non ethylene oxide method and made of synthetic Polysulfone hollow fibre with surface area 0.8m2 requirement- 150/year). The dialyzer and arteriosenous blood line or same manufacturer would be preferred. II? pediatric arteriovenous line (blood tubing): The pediatric arleriovenous blood line should be pre stenlised and latex free with arterial chamber. venous chamber with respective arterial and venous luer locks and injection ports in the tubing and ends or the tubing fitted with suitable connectors to the access and dialyzer. The dialyzer and arteriovenous blood line of same manufacturer would be preferred. ____-______ 9. Plasma filter for Pla.smapheresis: The plasma filter for therapeutic plasmapheresis in renal failure patients pre sierilised with polysulfonepolyethylene membrane with effective surface area- 0.5m- 0.6 m2 (requirement_ ____? l0Oyear) ______________________________ 10. Double lumen catheter for Hemodialysis with Kit The double lumen catheter for hemodi.alysis in patients It should be pre sterilized, of flexible radio opaque polyurethane material make with J end guide wire (gudewire MUST be of good qualtty), V shaped double entry introducer needlevessel dilator with arterial and venous port caps. syringe 5-10cc with luer lock It should be antmicrobial coated Size of the double lumen catheters to be supplied are L A. 8F B-9cmiqurementt 5o/year). — 1n1. Double lumen catheter for Hemodialysis with Kitt The double lumen aatheter for hemodialysis in patients. It should be pre sterilized, of flexible radio opaque polyurethane materal make with J end guide wire (guidewire MuST be of good quality). V shaped double entry introducer needlevessel dilator with arterial and venous port caps, syringe 5-10cc with luer lock. It should be antimicrobial coated. Size of the double lumen catheters to be supplied are B_11.5F-12F.13-14cm (requirement- 50/month) • ‘ - • TWfl ‘1 ‘‘ n1!r ni—i wnri r • 12. Tnple lumen catheter for Hemodialysis with Kit The tnple lumen catheter for hemodealysis in patients It should be pre stenhzed, of flexible radio opaque polyurethane matenal make with J end guide wire (guedewire MUsT be of good quality). V shaped double entry introducer needle vessel dilator with arterial and venous port caps. syringe 5-10cc with luer lock It should be antimicrobial coated Size of the triple lumen catheters to be supphed are _____ c.11m5F-12F ‘13.14cm (requirementl 50/month) 13. Biopsy Gun Kidney biopsy gun with size A. 16 Gauze 16cm needle (requirement- 100/yearwith penetration depth 18-22mm, pre sterile, automated sprng loaded Spring quality must be of good quality L to ensure smooth woading and to prevmnt misfire 14. Biopsy Gun: Kidney biopsy gun wtth size 18 Gauzex 16cm needle (requirement- 50/year) with penetration depth 18-22mm, pre sterile, automated spnng loaded Spring quality must be of good quality ___ • to ensure smooth loading and toprevent misfire IS. Peretoneal dialysis catheter Kit to include pre sterilised ngid pentoneal dialysis catheter with single cuff with metal stiletto with pointed end, scalpel with I holder, connector with flow regulator The catheter to be supplied with peritoneal dialysis fluid administration set Pentoneal deaysis catheter with drrnnistration set requirement- adult—20o.’sears_ / 16. Pentone dialyses catheter Kit to include • sterilisedingid penioneal dialysis catheier wiah siigie cuff with metal stiletto with pointed end, scalpe’ with holder connector with flow regulator The catheter to be supplied with peritoneal dialysis fluid • I administration set. Pertoneal dialysis catheter with ___-_ administration set (requirement-; pediatric-50/year) — 17. High Concentrate Part A Hemodialysis solution 1. High concentrate A HO Solution compatible with dry bag part B powder. Company must be Iso & GMP Certified. 2. Fluid composition: Sodium 103 mmol/L, chloride 109.5 mmol/L Cakium 1.7s mmol/L Magnesium 0.5 mmol/1., Potassium 2mmol/t Presence of glucose inHD fluid solution Is optional. IS Citrosterd- 5 hIre cans I 9. 6%sodiunmhypochloRe- 5 litre cans 20. Acetic acid glacIal- 5 hire cans 21. Citric acid monohydrat. 500gm. 22. Hydrochlorc acid-5 btre cans 23 lnlection of Baslliximab 20 Mg 24 Rabbit antithymoglobulin 250 Mg High Flux Hemodialyzer ith tubing Specification: Non ethylene oxide presterlyzed high performance membrane and hollow tTher type. Ultrafiltration coefficient (KUF) is >15 ml!hmmhg and B2-M clearance >15 m[min. compatible with most hemodialysis machines. High biocompatible materials such as polysulfone. lousing polycarbonate or polypropylene. Potting Compound should be polyurethane. Priming volumne. U coefficient. Clearance data (Urea. Creatinine, Phosphate, Vitamin B 12). Endotoxin retaining characteristics. Compatible ith most reprocessing machines and reprocessing fluid. Should have caps for blood inlet and outlet ports for safer storage. Dialyzers should meet European CE or USFDA aneH99d ISo standards. Iif[ectke surface area 1.6-2.0 sqm. l)ial3zer must be supplied with compatible tubing set. __-wmg Purosteril S ution 5 Ltr. 27 Dry bicarbonate Bag for Hemodialysis ss0 gram - High concentrate sodium citrate vial (23467%i

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 24-03-2022 As Per Nephrology Corrigendum Enclosed 30-03-2022

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 60 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail