Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-03-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 18-03-2022 |
| 2 | 10-03-2022 | DATECORRIGENDUM40 | Date | 11-03-2022 |
| Sl. No. | Item Description |
| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge. |
| 2 | Point wiring (in existing conduits concealed to surface) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in existing conduit of any type and any dia including making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. |
| 3 | Description all as per serial item No- 2.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board. |
| 4 | Description all as serial item No- 2.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board. |
| 5 | Point wiring (in existing conduits concealed to surface) for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in existing conduit of any type and any dia including making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. |
| 6 | Point wiring (concealed to surfaces) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit,fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. |
| 7 | Description all as serial item No- 7.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board. |
| 8 | Description all as per serial item No- 7.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board. |
| 9 | Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. |
| 10 | Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge. |
| 11 | Socket outlet,5-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge. |
| 12 | Switch socket combination, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge. |
| 13 | Switch socket combination 2-in-1, 3-pin and 5 pin, 5 and 15 Amp flush type universal type, complete all as specified and as directed by Engineer-In-Charge. |
| 14 | Electronic dimmers, 450W, 250V flush type on the exiting phenolic laminated sheet etc. as reqd, complete all specified and as directed by Engineer-In-charge. |
| 15 | Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge. |
| 16 | Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings inlcuding retrofit LED lamp of 9 Watt, complete all as specified and as directed by Engineer-In-Charge. |
| 17 | LED tube light fitting, 20 watt, indoor decorative aluminium extruded T5 LED battens, including LED lamp 20 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size including taking down existing light and making good disturbed surfaces of walls, complete all as specified and as directed by Engineer-In-Charge.Make: Havells cat part No- E-Lite LED Pride Plus LHEXBLP7PN1W020 or Equivalent Makes in Crompton/Philips/Osram. |
| 18 | S & F Inverter LED Batten with opal diffuser, IP20, battery back-up & functioning as per product TDS, 20 Watt, complete with all accessories with twin core twisted flexible copper conductor cable with suitable size all as specified and directed. Havells cat part No- PRIDE PLUS INVERTER BATTEN LHEXACP7FN1W020 or Equivalent Makes in Crompton/Philips/Osram. |
| 19 | Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of high brightness LEDs lamp of 10 Watt, complete all as specified.Make: Havells ordering cat part No- HEXAFT10WLED857SSYMBOPC or equivalent in Bajaj/ Philips/ Wipro. |
| 20 | Ceiling light, size 600x600mm, with bright LEDs of 36 Watt, having superior illumination, connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-In-Charge.Make: Crompton cat part No- CCR-127-36-57-SL-NWH (Aura-I) or equivalent in Phillips/ Havells/ Wipro. |
| 21 | Sub main wiring in repair(concealed conduits to surfaces) for circuits/ sub main wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 2.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge. |
| 22 | Sub main wiring in repair(concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge. |
| 23 | Sheet metal enclosuresin repairfor Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed. |
| 24 | Sheet metal enclosuresin repairfor Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 12-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed. |
| 25 | MCB, Triple Pole and Neutral, 63 Amps, 415 volts 10 KA, 50 Hz, \"C\" curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge. |
| 26 | MCB, Single Pole and Neutral, 40 Amps, 240V, 10KA, 50 Hz, \"C\" curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge. |
| 27 | MCB, single pole, 6 to 32 Amps, 240V, 10KA, 50 Hz, \"C\" curve, including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge. |
| 28 | Supply and fixing in replacement, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 10.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart Including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and as directed by Engineer-In-Charge. |
| 29 | Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt fillingwith fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates -2020 Reduced by (-25%).(ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost. |
| 30 | M&L for Servicing of ceiling fans of sweep 1200/1400mm including taking down from site, dismantling, cleaning, greasing/oilingof bush and bearings, replacement of set of split pins and other defective parts, cotter pins, blade screws and refixing to the existing site after servicing complete all as directed. Note :- (Unserviceable parts other than specified in this item if any will be measured seperately as supply only). |
| 31 | M&L for Servicing of Exhaust fans of sweep 300mm to 450mm including taking down from site, dismantling, cleaning, greasing/oilingof bush and bearings, replacement of set of split pins other defective parts, cotter pins, blade screws and refixing to the existing site after servicing complete all as directed .Note :- (Unserviceable parts other than specified in this item if any will be measured seperately as supply only). |
| 32 | Rewinding of ceiling fanmotor of size 1200mm/1400mm with super enamelled copper winding wire ofexisting gauge affter cutting and removing the burnt existing winding including varnishing heating by providing fresh insulating materials , complete all as specified and as directed by Engineer-In-Charge. |
| 33 | Rewinding of exhaust fan/wall monting fan motor of size 300mm with super enamelled copper winding wire of existing gaugeaffter cutting and removing the burnt existing winding including varnishing heating by providing fresh insulating materials, complete all as specified and as directed by Engineer-In-Charge. |
| 34 | All as per Srl Item No-33 here-in-above butforexhaust fan of size 400/450 mm of any make complete all as specified. |
| 35 | Supply onlyball bearing of ceiling / exhaust fan of any size and make as required with alignment of shaft and testing , complete all as specified and as directed by Engineer-In-Charge..Make - SKF |
| 36 | Supply only AC film capacitor 4.0 mfd, 440 volts suitable for any type exhaust fan in FR plastic casing including connection complete.Make - Havells cat ref no. 4.0 mfd / 440V / PLWW / 28x52 or equivalent in Epcos / Usha as approved. |
| 37 | Supply only AC film capacitor 2.5 mfd, 440 volts suitable for any type ceilingfan in FR plastic casing including connection , complete all as specified and as directed by Engineer-In-Charge..Make - Havells cat ref no. 2.5 mfd / 440V / PLWW / 25x45 or equivalent in Epcos / Usha as approved. |
| 38 | Supply only fan blades made of MS sheet duly powder coated ,of type make and colour as of ceiling fan suitable for 1200mm sweep ceiling fan of any make incl all accessories , complete all as specified and as directed by Engineer-In-Charge. |
| 39 | Supply only Blade assembly of Exhaust fan with fixing hexagonal nut of size 300 to 450mm of existing make and colour of product, complete all as specified and as directed by Engineer-In-Charge. |
| 40 | Supply only iron Frame of exhaust fan 4 way with welded and painted, complete all as specified and as directed by Engineer-In-Charge. |
| 41 | Supply only Gun metal bush of exhaust fan of any sweep, complete all as specified and as directed by Engineer-In-Charge. |
| 42 | Supply only rubber reel with a pair of clamp, nuts, bolts, split pins etc suitable for ceiling fan down rods of any size and make as required , complete all as specified and as directed by Engineer-In-Charge. |
| 43 | Supply only PVC canopy suitable for ceiling fan of any size and make as required , complete all as specified and as directed by Engineer-In-Charge. |
| 44 | Supply only PVC insulated and sheathed flexible 3 core cable with copper conductor of size 0.5 sqmm , complete all as specified and as directed by Engineer-In-Charge. |
| 45 | Supply only down rod of ceiling fan made of GI pipe medium grade 15 mm bore of length upto 600 mm including cutting, threading, painting etc as required. |
| 46 | Taking down of desert cooler fixed at any position, cleaning internally and externally by scraping all scales dirt etc and repairs to desert cooler to check leakage, tightening ( By replacing screws, nuts and bolts etc )including painting of desert cooler with spray machine with two coats of synthetic enamel hammer tone paint over one coat of red oxide primer, letters, Refixing of the desert cooler after necessary oilling and greasing of fan and water lifting pump and repalcement of necessary defective parts, complete all as specified and directedNote :- (Unserviceable parts other than specified in this item if any will be measured seperately as supply only). |
| 47 | Supply only Fan motor 1/6 HP, 230 volt, single phase for the existing desert coolercomplete all specified and directed( Make Khaitan ) |
| 48 | Supply only Water lifting pump, Vertical type,18 watts, 230 volt, 50 C/S, single phase suitable for desert coolers complete all specified and directed ( Make : Khaitan ) |
| 49 | Supply only Side panel made out of 1.0 mm thick GI sheet, fixed with iron handle suitable for desert coolers of capacity 3000 cfm including two coats of synthetic enamel hammer tone paint over a one coat of red oxide primer on both side of panel complete all specified and directed |
| 50 | Supply only High density polythene pipe 15 mm dia complete all specified and directed |
| 51 | Supplyingin replacement Complete steel body of desert cooler of capacity 3000 cfm duly painted with two coats of synthetic enamel hammer tone paint over one coat of red oxide primer . The body of desert cooler shall be fabricated as under:-( a ) The top and bottom made out of 1.25 mm thick GI sheet.( b ) side panels (set of three) made out 1.00 mm thick GI sheet.( c ) Front grill of suitable size and of approved quality. |
| 52 | Supply only Three way water distributor, heavy duty, PVC, including necessary nuts and bolts complete and taking out old distributor complete all specified and directed |
| 53 | Supply only Selector Switch regulator, suitable for Desert coolers exhaust fan of any make complete all specified and directed |
| 54 | Re-wiring of desert coolerwith suitable size of copper conductor PVC insulated cable and providing main lead three metre long of 3 core PVC insulated copper conductor of size 23/ .0076 complete all specified and directed. |
| 55 | Dismantingand taking out Old, Unservicable fan motor from the desert cooler and Rewinding with supper enamel copper winding wire of suitable size, varnishing etc including replacement of bushes, assembling testing and refixing at the existing site complete all as specified and directed |
| 56 | M& L forfabrication of desert cooler stand made out of MS angle iron 40x40x6mmthick all as per existing sizesuitable at site incl painting ith two coats of synthetic enameld paint over a coat of red oxideprimer coat . |
| 57 | Repairs to voltage stabilizer of any make, single phase with input voltage 135 - 190 V and out put voltage 200-240 volt, capacity 5 KVA by dismantling and taking out burnt main transformer and rewinding with super enamelled copper wire of suitable size including varnishing and insulation material etc.complete all as specified and directed |
| 58 | All as per item No- 57.00 here in before but of capacity 03 KVA |
| 59 | All as per item No- 57.00 here in before but of capacity 01 to 02 KVA |
| 60 | Dismantling and servicing of cooling appliances including cleaning, painting, necessary test of leakage by nitrogen gas, brazing, compressed air wash and make the system functional complete all as specified for window type AC of any capacity. |
| 61 | All as per item No 60.00 here in before but of Water Cooler of any capacity |
| 62 | All as per item No 60.00 here in before but for Refrigerator of any capacity |
| 63 | Remove the unserviceable fan motor from window AC any capacity removing the burnt out winding wire fromslots, clean slots with emery paper and rewind the same with superior quality copper wire insulate properly and bringing back and fixing in position and testing and commissioning:- |
| 64 | All as per item No63.00here in before but for Water Cooler upto 150 Ltrs capacity |
| 65 | Replacement of unserviceable air filter for window AC, complete all as specified and directed |
| 66 | S&Frelay of Refrigerator of the same make and type, complete all as specified and directed |
| 67 | Disconnect the suction and discharge line to the unserviceable compressor, replace with the new compressor brought from the factory of the same make connect the refregerent lines systems flushing vacuumising of the entire system arrest all leakages including testing and commissioning forwindow AC 1.5 ton capacity |
| 68 | All as per item No-67.00 here in before but for Water Cooler above 60 ltrsupto 150 Ltrs capacity |
| 69 | All as per item No-67.00 here in before but for Water Cooler40 to 80 Ltrs capacity |
| 70 | All as per item No-67.00 here in before but for Refrigerator 165 to 320 Ltrs capacity |
| 71 | Replacement of unserviceable thermostatof AC up to 1.5 Ton, complete all as specified and directed |
| 72 | All as per item No 67.00 here in before but for Water Cooler upto 150 Ltrs capacity |
| 73 | All as per item No 67.00 here in before but for Refrigerator up to 320 Ltrs capacity |
| 74 | Remove the unserviceable fan blade fromthe condenser cooling motor and replace with new fan blade of same size and type for Water Cooler any capacity, complete all as specified and directed |
| 75 | All as per item No 74.00 here in before but for Air conditioners up to 1.5 Ton. |
| 76 | Replacement of unserviceable float valve with new brass Float valve of water cooliers/ desert coolers complete15 mm dia , complete all as specified and directed |
| 77 | Flushing & vacuumising the system and charging of necessary refrigerent at required quantity for Window AC cap 1.5 Ton, complete all as specified and directed |
| 78 | All as per item No-76.00 here in before but for Refrigerators ofany capacity. |
| 79 | All as per item No-76.00 here in before but for Water coolers of any capacity. |
| 80 | Disconnecting the inlet and outlet connections of the existing Geyser 25/50 Ltr, taking down carefully, cleaning/descaling the blocks both in GI pipes and water heater refixing the bolts by proper grouting in the wall and refixing the water heater in the same or in other places as directed. |
| 81 | Replacement of unserviceable heating element of geyser 2KW/1.5 KW of any pattern all as specified. Make: Dasspass/Recold/Bajaj. |
| 82 | Replacement of unserviceable thermostat of geyser 2KW/1.5 KW of any pattern all as specified. Make: Dasspass/Recold/Bajaj |
| 83 | Replacement of unserviceable PVC flexible pipe inlet 16mm outer dia and 450 mm long for hot/cold water heavy duty with brass nuts & bolts, complete all as specified and directed |
| 84 | Disconnecting all electric connections of Deep freezer of any type and any capacity, for repairing and servicing, by cleaning/ washing the internal chamber, compressor, evaporator (indoor unit), condenser and lubrication of movable parts, tightening the hinges and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge.Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items.(ii) Cost of transportation from site to workshop for repair and return from workshop to site shall be deemed to be included in quoted rates of the item. |
| 85 | Supply only Hermetic sealed unit (compressor unit), capacity 2.50 Ton, uncut, suitable for deep freezer, complete all as specified and as directed by Engineer-In-Charge. |
| 86 | Supply only Printed Circuit Board, three phase, suitable for walk in freezer, any type, and as per existing specifications, complete all as specified and as directed by Engineer-In-Charge. |
| 87 | Supply only Condensor fan motor of 1/8 HP for Deep freezer, capacity 250 to 350 liters, complete all as specified and as directed by Engineer-In-Charge. |
| 88 | Supply only Recharging/ replacement/ filling of refrigerant (R-134a), suitable for deep freeze of any capacity and any specifications including testing and repairing against any leakage by welding, soldering, complete all as specified. |
| 89 | Supply and fixing in replacement with new Energy efficient Inverter Security light 45 watt with RTC/RTC DIMM/ IR SENSE/IRSENSE DIMM, PDC housing, IP 66, with battert back-up, Auto ON/OFF/DIMM & functioning as per product TDS, including taking down old UNSV security lights all as specifeid and directed. Make : Halonix Cat Part No :- LED SL 45 W HLSLD-ML04-45-CWL-INV-RTC-R or equivalent in Havells/Crompton Greaves/C&S/Philips. |
| 90 | Supply and fixing in replacement with new Energy efficient Inverter Security light 60 watt with RTC/RTC DIMM/ IR SENSE/IRSENSE DIMM, PDC housing, IP 66, with battert back-up, Auto ON/OFF/DIMM & functioning as per product TDS, including taking down old UNSV security lights all as specifeid and directed. Make : Halonix Cat Part No :- LED SL 60 W HLSLD-ML04-60-CWL-INV-RTC-R or equivalent in Havells/Crompton Greaves/C&S/Philips. |
| 91 | Supply and fixing in replacement with new Energy efficient Inverter Security light 90 watt with RTC/RTC DIMM/ IR SENSE/IRSENSE DIMM, PDC housing, IP 66, with battert back-up, Auto ON/OFF/DIMM & functioning as per product TDS, including taking down old UNSV security lights all as specifeid and directed. Make : Halonix Cat Part No :- LED SL 90 W HLSLD-ML04-90-CWL-INV-RTC-R or equivalent in Havells/Crompton Greaves/C&S/Philips. |
| 92 | LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection, including LED lamps of 45 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified.Make: Havells cat part No- Endura Pearl Neo SL45WLED757SASYTOPC/ Philips ordering code No- 910925866055 (Product Code- 871869634894900) or equivalent in Osram. |
| 93 | LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in surge protection device, including LED lamps of 60 Watt and connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and as directed by Engineer-In-Charge.Make: Havells cat part No- Endura Pearl Plus SL60WLED757SASYTOPC/ Philips ordering code No- 910925865969 (Product Code- 871869632029700) or equivalent in Osram. |
| 94 | LED street light New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC coverhaving TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07with 10KV Built-in Surge Protection Device, including LED lamps of 90 Watt and connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and as directed by Engineer-In-Charge.Make: Havells cat part No- Endura Pearl Plus ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO/or equivalent in Philips/Osram. |
| 95 | Carryout periodic maintenance of DG set capacity 62.5 KVAMake : \"Cummins\" by calibration of fuel injection pump including dismantling of radiator, radiator fan, water pump assembly, air cleaner, rocker cover housing rocker, oiling and greasing to movable spare parts such as bearing etc, replacement of old defective air filter, fuel filter, oil filter, insulation cover/ asbestos rope of exhaust pipe with new and manufacturer specified air filter, fuel filter and oil filter, insulation cover/ asbestos rope of exhaust pipe tightening the screws of hose and hose pipe set, strip opening of alternator cleaning of stator and field coils, rotor assembly, and apply one coat of varnishing using ‘H’ class varnish and complete service work as required at site, re-assembling the engine/ alternator in existing position, and testing on completion installed at Pump House Pallanwala completeall as directed by Engineer-In-Charge. Note: New spare parts will be measured and paid separately as supply only under the respective items. |
| 96 | Supply only following new spare parts required for repair of DG Set capacity 62.5 KVA :-(a) Piston with piston pin, connecting rod and lock assembly complete. |
| 97 | (b) Cylinder liner with liner ring assembly complete. |
| 98 | (c) Piston ring set. |
| 99 | (d) Main Bearing. |
| 100 | (e) Connecting rod bearing of 6-pairs. |
| 101 | (f) Small end bearing |
| 102 | (g) Major overhauling gasket set with \"O\" ring set. |
| 103 | (h) Head valve inlet and exhaust. |
| 104 | (j) Main Oil seal (Front and Rear). |
| 105 | (k) Hose pipe with clips and joint set. |
| 106 | (l) Fuel Filter. |
| 107 | (m) Oil Filter. |
| 108 | (n) Air cleaner filter |
| 109 | (o) V-Belts |
| 110 | Supply onlyset of 4 nos high pressure copper tubes of required size from FIP to injectors for DG set 62.5 KVA , complete all as specified and as directed by Engineer-In-Charge. |
| 111 | Supply onlyEngine temperature gauge suitable for DG set of capacity 62.5 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 112 | Calibration, repair, checking of fuel injector nozzle assembly of DG set capacity 62.5 KVA, transport to workshop including replacement of injector nozzle cap, barrel and small spares required for smooth functioning of injector nozzle, complete all as specified and as directed by Engineer-In-Charge. |
| 113 | Replacement of old unserviceable/ damaged battery with new storage cell lead acid type 12 Volts, 150 AH including lead terminals and copper thimble for making necessary connections, complete all as specified and as directed by Engineer-In-Charge.Make - Exide/ AMCO Insta Power/ Amaron Quanta as approved |
| 114 | Supply only copper lead cable 2 mtrs long, multi-stranded, with copper thimble for making necessary connections at both ends, suitable for 12 Volts including copper nuts, bolts and washers, complete all as specified and as directed by Engineer-In-Charge. |
| 115 | De-assembling of radiator for cleaning and repair, using ‘K’ oil and radiator cleaning solution hydro-chloric acid by pressure of pump/ caustic soda with wire brush and necessary welding/ brazing of water tubes/ fins, whichever is required for cleaning and repairing, complete all as specified and as directed for 30 to 62.5 KVA DG Set. |
| 116 | Overhauling Fuel Injection Pump by replacing the elements, D - Valves, O- rings, nozzles, bearing and gaskets and reassembling the new parts and calibrating in MICO test bench as per manufaturer specification all as directed for 62.5 KVA DG Set. |
| 117 | Supply and filling engine oil SAE 20w - 40 Make : Sawita/Volvoline |
| 118 | Supply and filling radiator coolant oil Make : Volvoline |
| 119 | Supply and fix in replacement of self starter assembly 12 volt suitable for 62.5 KVA DG set |
| 120 | Disconnecting electric connections from alternator, capacity 62.5 KVA, decoupling of engine and alternator, separaing from base plate, and transporting to workshop for repairs and return back to it\"s original position after repairs including loading and unloading, by mechenical means, replacing defective spare parts with new spare parts, including any type of machine work required at site/ workshop to compete the repair including complete servicing all as required at site, re-assembling in existing position complete and testing on completion all as specified and as directed by Engineer-In-Charge Note: (a) New spare parts will be measured and paid separately as supply only under the respective items.(b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling of alternator will deemed to be included in quoted rates. |
| 121 | Supply only new carbon bush suitable for alternator of DG set capacity 62.5 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 122 | Supply onlycarbon bush holder suitable for alternator of DG set capacity 62.5 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 123 | Supply onlyelectronic rectifier/ Automatic Voltage Rectifier with new electronic rectifier/ Automatic Voltage Rectifier suitable for DG set capacity 62.5 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 124 | Supply only slip ring assembly suitable for DG set capacity 62.5 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 125 | Supply only solenoid switch suitable for self starter capacity 12 Volts,for DG set capacity 62.5 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 126 | Carryout periodic maintenance of DG set capacity 30 KVAMake : \"Mahindra\" by calibration of fuel injection pump including dismantling of radiator, radiator fan, water pump assembly, air cleaner, rocker cover housing rocker, oiling and greasing to movable spare parts such as bearing etc, replacement of old defective air filter, fuel filter, oil filter, insulation cover/ asbestos rope of exhaust pipe with new and manufacturer specified air filter, fuel filter and oil filter, insulation cover/ asbestos rope of exhaust pipe tightening the screws of hose and hose pipe set, strip opening of alternator cleaning of stator and field coils, rotor assembly, and apply one coat of varnishing using ‘H’ class varnish and complete service work as required at site, re-assembling the engine/ alternator in existing position, and testing on completion installed at Pump House Pallanwala completeall as directed by Engineer-In-Charge. Note: New spare parts will be measured and paid separately as supply only under the respective items. |
| 127 | Supply only following new spare parts required for repair of DG Set capacity 30 KVA :-(a) Piston with piston pin, connecting rod and lock assembly complete. |
| 128 | (b) Cylinder liner with liner ring assembly complete. |
| 129 | (c) Piston ring set. |
| 130 | (d) Main Bearing. |
| 131 | (e) Connecting rod bearing of 4-pairs. |
| 132 | (f) Small end bearing |
| 133 | (g) Major overhauling gasket set with \"O\" ring set. |
| 134 | (h) Head valve inlet and exhaust. |
| 135 | (j) Main Oil seal (Front and Rear). |
| 136 | (k) Hose pipe with clips and joint set. |
| 137 | (l) Fuel Filter. |
| 138 | (m) Oil Filter. |
| 139 | (n) Air cleaner filter |
| 140 | (o) V-Belts |
| 141 | Supply only set of 4 nos high pressure copper tubes of required size from FIP to injectors for DG set 30 KVA |
| 142 | Supply only Enginetemperature gauge with new Engine temperature gauge suitable for DG set of capacity 30 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 143 | Calibration, repair, checking of fuel injector nozzle assembly of DG set capacity 30 KVA, transport to workshop including replacement of injector nozzle cap, barrel and small spares required for smooth functioning of injector nozzle, complete all as specified and as directed by Engineer-In-Charge. |
| 144 | Overhauling Fuel Injection Pump by replacing the elements, D - Valves, O- rings, nozzles, bearing and gaskets and reassembling the new parts and calibrating in MICO test bench as per manufaturer specification all as directed for 30 KVA DG Set. |
| 145 | Supply and fix in replacement of self starter assembly 12 volt suitable for 30KVA DG set , complete all as specified and as directed by Engineer-In-Charge. |
| 146 | Disconnecting electric connections from alternator, capacity 30 KVA, decoupling of engine and alternator, separaing from base plate, and transporting to workshop for repairs and return back to it\"s original position after repairs including loading and unloading, by mechenical means, replacing defective spare parts with new spare parts, including any type of machine work required at site/ workshop to compete the repair including complete servicing all as required at site, re-assembling in existing position complete and testing on completion all as specified and as directed by Engineer-In-Charge Note:(a) New spare parts will be measured and paid separately as supply only under the respective items.(b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling of alternator will deemed to be included in quoted rates. |
| 147 | Supply only new carbon bush suitable for alternator of DG set capacity 30 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 148 | Supply only new carbon bush holder suitable for alternator of DG set capacity 30 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 149 | Supply only new electronic rectifier/ Automatic Voltage Rectifier suitable for DG set capacity 30 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 150 | Supply only new slip ring assembly suitable for DG set capacity 30 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 151 | Supply only new solenoid switch suitable for self starter capacity 12 Volts, of DG set capacity 30 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 152 | Replacement of old unserviceable/ damaged Change over switch with new Change over switch, on load, rating 200 Amps, four poles, 415 Volts, AC, 50 Hz, with center handle, conforms to IS:13947 (Part-3); IEC:60947-2, with stain less steel enclouser complete all as specified and as directed by Engineer-In-Charge.Make: Indo-Asian cat part No- ICAS0200 or equivalent in L&T/ Legrand/ Merlin Gerin/ Siemens. |
| 153 | Supplying and laying or fixing or passing through pipe,1100volts grade heavy duty cable with PVC insulated aluminium stranded conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed in service connections of size 16 sqmm, 4 core including taking down old UNSV service cable complete all as specified and directed by Engineer-in-Charge. |
| 154 | Supplying and laying or fixing or passing through pipe,1100volts grade heavy duty cable with PVC insulated aluminium stranded conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed in service connections of size 16 sqmm, 2 core including taking down old UNSV service cable complete all as specified and directed by Engineer-in-Charge. |
| 155 | Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, for laying pipe line etc, complete all as specified and as directed by Engineer-In-Charge. |
| 156 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge. |
| 157 | Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge. |
| 158 | Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge.Note: Punned thickness shall be measured. |
| 159 | Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified. |
| 160 | Supply and fixing in replacement of for under ground Cable, LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly, IS-7098 Part-II, with stranded aluminum conductor LT 1100 volts grade of size 25 Sqmm 4 core including disconnecting /getting out old unserviceable cable piece complete all as specified and directed. |
| 161 | Supply and fixing in replacement offor under ground Cable, LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly, IS-7098 Part-II, with stranded aluminum conductor LT 1100 voltsgrade of size 50 Sqmm 3.5 core including disconnecting /getting out old unserviceable cable piece complete all as specified and directed. |
| 162 | SPECIAL NOTE FOR DG SETS AND VOLTAGE STABLIZER\"S REPAIRS: The contractor will submit a scanned copy of Memorandum of under standing from OEMs ( or authorized dealers) for the respective E/M installations. The details of OEMs are as under:-(a)DG Set(i) Kirlosker Green/Cummins(ii) Crompton Greaves (iii)Sudhir (iv) Mahindra(b)Servo Voltage Stablizer(i)Vinitek(ii)Electric field |
| 163 | Amount of Schedule of credit of for Rs 1,05,597.00 shall be deducted from quoted amount. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy