| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and cheasseling/ cuuting wall for conceale point wiring with proper cementing work and making good disturbed surfaces of walls as existing colour wall, floors, etc. complete all as specified and directed. |
| 2 | Material and Labour for Concealed point wiring with FR PVC insulated unsheathed, stranded copper conductor cable single core 1.5 Sqmm for one lightpoint controlled by one one way switch incl one PVC insulated, un sheathed Single corestranded/solid copper conductor cable of size 1.5 Sqmm for continues earth wire .drawn in and including PVC conduit pipe heavy duty 20/25 mm dia complete with all accessories includingsheet metal MS box of suitable size of 1.2mm thickor PVC rectangular switch board of suitable size incl 3.0 mm thick laminated sheet cover and fixed with brass screws, cap washers etcto be fixed flushed on wall including white washing/colour washing/distembering to match the disturbed surfaces complete all as directed by Engr -in Charge. |
| 3 | All as per item No -2 above but for one fan point controlled by one switch. |
| 4 | All as per item No-2 but one light point controlled by two 2-way switches with cables 1.5 sqmm size. |
| 5 | All as per item No -2 above but for call bell/buzer controlled by one bell push. |
| 6 | All as per item No -2 above but for one 3/5 pin multi purpose5/6 Amps socket out let independent. |
| 7 | All as per item No -2 above but for one 15 Amps switch socket out let independent but using PVC insulated, unsheathed stranded copper conductor cable of size 2.5 Sqmm and 2.5sqmm for earth continuity conductorfor one 3 pin 15/16 Amps switch socket out let independent complete all as specified and directed. |
| 8 | Supply and fixingswitch piano flushtype, single pole, one way, 5 amps 230 volts complete all as specified & directed. |
| 9 | Supply and fixing switch socket combination 5 Amps 2 to3 pin flush type complete all as specified and directed. |
| 10 | Supply and fixing switch socket combination 15 Amps 3 pin flush type complete all as specified and directed. |
| 11 | Supply and fixing ceiling rose, surface bakelite 65x50 mm three terminal complete all as specified and directed. |
| 12 | Supply and fixing including connection of call bell AC-230 Volt single pole of multi music type complete all as specified and directed. |
| 13 | Supply and fixing bell push, flush type 5 Amps complete all as specified and directed. |
| 14 | Supply and fixing stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed. |
| 15 | Supply and fixing Sheet metal enclosures with socket plug top and MCBs single pole and neutral with 2 pin and earth plug and socket complete with one MCB 20A complete all as specified and directed. |
| 16 | S & F LED Light fitting 1x 18 W , 220 V AC decorative box type with driver holder including LED tube light connecting up 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 17 | S & F light fitting mirror type with high output diffuser 2 feet 10 watt 220 volt AC decorative type with driver holder and LED lamp including connecting up with flexible 3 core copper cable of suitable size complete all as specified and directed. |
| 18 | Taking downExisting Fan / Exhaust Fan and after complete re-wing of building same to be re-fixed complete all as directed by Engineer in Charge. |
| 19 | Taking downWater heater (Geyser) and after complete re-wiring of building same to be re-fixed complete all as directed by Engineer in Charge. |
| 20 | Taking downold unserviceable switch fuse unit / MCB / MCCBDB with MCB etc for necessary repair/replacementand re-use complete all as directed by Engineer in Charge. |
| 21 | Supply and fixing of MCB TPN DB4 waymade of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail, 230 Volts with Double door. |
| 22 | Supply and fixing of MCB SPN DB8 waymade of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail, 230 Volts with Double door. |
| 23 | Supply and fixing of MCB SPN DB12 waymade of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail, 230 Volts withDouble door. |
| 24 | Supply fixing, connection and testing MCB TPN 240 Volts, \"C\" series, breaking capacity 10 KA of rating 40 to 100 Amps. |
| 25 | Supply fixing, connection and testing MCB SPN 240 Volts, \"C\" series, breaking capacity 10 KA of rating 32 Amps. |
| 26 | Supply fixing, connection and testing MCB SP 6-32 Amps. |
| 27 | Taking down Old U/S submain wiring of any size & any capacity from its existing position complete all as specified & directed. |
| 28 | M & L Submainwiringwithtwosinglecoremultistranded coppercableof2x 2.5 Sq mm &onesolidcoppercableof 2.5 Sq.mmforcontineuousearthwire bothPVCinsulated&un- sheatheddrawnthroughandincludingPVC heavy dutyPVC Conduit 20/25 mm dia complete with all accessories or to be fixed on wall respectively including white washing/ colour washing/ distembering to match the disturbed surfaces complete all as specified and directed. |
| 29 | M & L Submainwiringwithtwosinglecoremultistranded coppercableof2x4.0 Sq.mm &onesolidcoppercableof 4 Sq.mmforcontineuousearthwire bothPVCinsulated&un- sheatheddrawnthroughandincludingPVC heavy dutyPVC Conduit 20/25 mm dia complete with all accessories or to be fixed on wall respectively including white washing/colour washing/ distempering to match the disturbed surfaces complete all as specified and directed. |
| 30 | Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6.3mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanisedearth lead wire 4.0mm , by means of nuts, bolts,check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 32mm bore light grade from earthing test point or main controling switch as directed including providing funnel with 20mm bore GI pipe light grade, wire mesh,charcoal or coke and common salt in alternative layer of 15 Cm (compactedd thickness) all round the earth electrode,concrete earth pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 50mm thick cover of RCC (1:2:4) (re-inforced with 8mm dia TMT bar @15 cm C/C bothways and MS bar handle made of 10mm dia bar) including necessary earth work in excavation,returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 3 of MES Schedule Part-I including earthing pit cover etc. complete all as specified and directed. |
| 31 | Earth continuity conductor or main earthing lead fixed to wall on butten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or many other indirected situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and as directed. |
| 32 | M & L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm , 3.5 core complete all as specified and as directed. |
| 33 | Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in soft / loose soil complete all as specified and as directed. |
| 34 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all specified and as directed. |
| 35 | Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and directed. |
| 36 | M&L for sand cushioning with coarse sand in trenches for protection of underground electric cable, spread to uniform 23 cm thickness and punned down gently to 18 cm after. Note :- Compacted thickness shall be measured and paid. |
| 37 | Supply and laying well burnt sub-class \"B\" bricks old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and directed. |