}

Bids Are Invited For 1 Fgm Fgm / Electrician ( Skilled ) Per Person As Per Existing Rates. 2 Item No 2 Employees Provident Fund As Per Existing Rates 3 Item No 3 Employees State Insurance As Per Existing Rates 4 Item No 4 Over Head & Profit On Tota, Tiruvallur-Tamil Nadu

Statutory Bodies & Commissions/Committees has published Bids Are Invited For 1 Fgm Fgm / Electrician ( Skilled ) Per Person As Per Existing Rates. 2 Item No 2 Employees Provident Fund As Per Existing Rates 3 Item No 3 Employees State Insurance As Per Existing Rates 4 Item No 4 Over Head & Profit On Tota. Submission Date for this Tender is 23-02-2022. Cushioning Supplies Tenders in Tiruvallur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

31023925
Corrigendum : Bids Are Invited For 1 Fgm Fgm / Electrician ( Skilled ) Per Person As Per Existing Rates. 2 Item No 2 Employees Provident Fund As Per Existing Rates 3 Item No 3 Employees State Insurance As Per Existing Rates 4 Item No 4 Over Head & Profit On Tota
Open Tender
Indian
Tamil Nadu
Tiruvallur
23-02-2022

Tender Details

Bids Are Invited For 1 Fgm Fgm / Electrician ( Skilled ) Per Person As Per Existing Rates. 2 Item No 2 Employees Provident Fund As Per Existing Rates 3 Item No 3 Employees State Insurance As Per Existing Rates 4 Item No 4 Over Head & Profit On Total Of Srl No. 10.00 To 12.00 5 Item No 5 Labour Welfare Cess ( Lwc ) On Total Of Srl No. 10.00 To 13.00 6 Item No 6 Gst As Per Existing Rates On Total Of Srl No. 10.00 To 14.00 7 Item No 7 Excavating In Trenches, Not Exceeding 1.5M Wide And Not Exceeding 1.5M In Depth; For Foundation, Laying Cables, Pipes Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc Not Exceeding 10 Sqm On Plan And Not Exceeding 1.5M Depth And Getting Out In Any Type Of Soil All As Specified And As Directed. 8 Item No 8 Removing Excavated Surplus Soil To A Distance Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And As Directed. 9 Item No 9 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25 Cm In Any Type Of Soil Complete All As Specified And As Directed. 10 Item No 10 Fine Sieved Excavated Dry Soil Laid To Required Width Of Trench At Bottom And Top For Cable Cushioning All As Specified And As Directed. Note: ( A ) Punned Thickness Only Shall Be Measured. ( B ) The Soil Used Shall Be Free From Sharp Grains And Deletrios Materials Like Dry / Decayed Plants Etc., 11 Item No 11 Burnt Bricks Sub Class B Of Old Size, Designation 50, Laid Dry In Trenches With Width Equal To Length Of Bricks Across The Cable For Cable Protection All As Specified And As Directed. 12 Item No 12 Taking Out Existing Cable Any Type / Cross Section And Supply, Laying, Connecting And Testing Xlpe Insulated, Armoured, Heavy Duty Electric Cable With Aluminium Conductor Of Cross Sectional Area 95 Sqmm, 3 Core, 11000 Volts Grade, In Trenches / Drawn Through Pipe / Fixed On Walls / Bare In Road Crossings / Paths / Drains / Ducts / Floors / Fixed On Poles / Equipments Complete All As Specified And As Directed. 13 Item No 13 Taking Out Existing Cable Any Type / Cross Section And Supply, Laying, Connecting And Testing Xlpe Insulated, Armoured, Heavy Duty Electric Cable With Aluminium Conductor Of Cross Sectional Area 25 Sqmm, 4 Core, 1100 Volts Grade, In Trenches / Drawn Through Pipe / Fixed On Walls / Bare In Road Crossings / Paths / Drains / Ducts / Floors / Fixed On Poles / Equipments Complete All As Specified And As Directed. 14 Item No 14 Taking Out Existing Cable Any Type / Cross Section And Supply, Laying, Connecting And Testing Xlpe Insulated, Armoured, Heavy Duty Electric Cable With Aluminium Conductor Of Cross Sectional Area 120 Sqmm, 3.5 Core, 1100 Volts Grade, In Trenches / Drawn Through Pipe / Fixed On Walls / Bare In Road Crossings / Paths / Drains / Ducts / Floors / Fixed On Poles / Equipments Complete All As Specified And As Directed. 15 Item No 15 Taking Out Existing Cable Any Type / Cross Section And Supply, Laying, Connecting And Testing Xlpe Insulated, Armoured, Heavy Duty Electric Cable With Aluminium Conductor Of Cross Sectional Area1 50 Sqmm, 3.5 Core, 1100 Volts Grade, In Trenches / Drawn Through Pipe / Fixed On Walls / Bare In Road Crossings / Paths / Drains / Ducts / Floors / Fixed On Poles / Equipments Complete All As Specified And As Directed. Note For Item No 21 & 24: ( I ) Earth Work Excavation Shall Be Measured And Paid Seperately Under Respective Items. ( Ii ) Lugs And Glands Shall Be Used Appropriately Wherever Required While Connecting Cable To The Panel Boardand Rate Quoted Shall Be Deemed To Include For The Same. 16 Item No 16 Cable Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Outdoor Termination Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 95 Sqmm As In Repairs Complete All As Specified And As Directed. 17 Item No 17 Air Break, Gang Operated Switch, With Current Rating 200 Amps, Ht, 11000 Volts, Triple Pole Mechanically Operated, Mounted On Insulator And Steel Frame, With Operating Mechanism Worked From Ground Level As In Repairs Complete All As Specified And As Directed. 18 Item No 18 Disc Type Insulator, Porcelain, Vitreous 145Mm High And 255Mm Dia Ball And Socket Type, White, Brown Or Green, Two In Series Assembly For Tension With Cast Aluminium, 4 U Bolt Tension Hardware And Tension Clamps For Conductors, Working Pressure 11000 Volts As In Repairs Complete All As Specified And As Directed. 19 Item No 19 Lightning Arresters Expulsion Type Complete With All Fittings, Transmission Class, Discharge Capacity 65 Kilo Amp 1100 Volts Rating As In Repairs Complte All As Specified And As Directed 20 Item No 20 Supply And Laying Synthetic Rubber Insulated Mat 19 Mm Thick For Voltage 11 Kv For Electrical Purpose As Per Is 15652-2006 Suitable For Electrical Shock Safety Of Size 2Mtrx1mtr As In Repairs Complete All As Specified And As Directed. 21 Item No 21 Supply And Laying Synthetic Rubber Insulated Mat 25 Mm Thick For Voltage 11 Kv For Electrical Purpose As Per Is 15652-2006 Suitable For Electrical Shock Safety Of Size 2Mtrx1mtr As In Repairs Complete All As Specified And As Directed. 22 Item No 22 Danger Notice Plate Of 1.6Mm Thick Mild Steel Sheet, Vitreous Enamelled White, With Letters, Figures And Conventional Skull And Bones In Signal Red Colour And Fixed With M.S. Clamps, Bolts And Nuts Of Approved Size, For Lt, 20X15cm Size Complete All As Specified And As Directed. 23 Item No 23 Taking Up And Down Steel Tubing And Connections And Taken On Credit And Provision Of Steel Tubing, Galvanised, Light Grade, With Necessary Fittings Such As Bends, Elbows, Tees Etc., And Laid In Bridges / Culvert / Trenches / Under Roads / Crossings Etc., Of Bore Of Pipe 100Mm For Cable Protection Complete All As Specified And As Directed. Note: Earth Work And Excavation As Required Shall Be Measured And Paid Seperately Under Respective Items. 24 Item No 24 S & F Horn Gap Type Fuse Unit, 11000 Volts Grade, Mounted On Insulators And Steel Frame, Single Pole, Fixed On Dp Structures All Specified And As Directed Including Dismantling Existing Unserviceable Fuse Unit. 25 Item No 25 Mccb 160 Amps, 4 Pole, 415 Volts, 3 Phase, 50 Hz, 36 Ka Breaking Capacity, Withadjustable Thermal And Fixed Magnetic Setting With Protection For Overload And Short Circuit And Conforming To Iec60947 / Is 13947 ( Pt-Ii ) 1993 ( Latest Version ) And With Ics = 100% Of Icu Having Spreader Links And Barriers As Standard Feature Of Manufacturer As In Repairs Complete All As Specified And As Directed. 26 Item No 26 Mccb 200 Amps, 4 Pole, 415 Volts, 3 Phase, 50 Hz, 36 Ka Breaking Capacity, Withadjustable Thermal And Fixed Magnetic Setting With Protection For Overload And Short Circuit And Conforming To Iec60947 / Is 13947 ( Pt-Ii ) 1993 ( Latest Version ) And With Ics = 100% Of Icu Having Spreader Links And Barriers As Standard Feature Of Manufacturer As In Repairs Complete All As Specified And As Directed. 27 Item No 27 Mccb 250 Amps, 4 Pole, 415 Volts, 3 Phase, 50 Hz, 36 Ka Breaking Capacity, Withadjustable Thermal And Fixed Magnetic Setting With Protection For Overload And Short Circuit And Conforming To Iec60947 / Is 13947 ( Pt-Ii ) 1993 ( Latest Version ) And With Ics = 100% Of Icu Having Spreader Links And Barriers As Standard Feature Of Manufacturer As In Repairs Complete All As Specified And As Directed. 28 Item No 28 Mccb 400 Amps, 4 Pole, 415 Volts, 3 Phase, 50 Hz, 36 Ka Breaking Capacity, Withadjustable Thermal And Fixed Magnetic Setting With Protection For Overload And Short Circuit And Conforming To Iec60947 / Is 13947 ( Pt-Ii ) 1993 ( Latest Version ) And With Ics = 100% Of Icu Having Spreader Links And Barriers As Standard Feature Of Manufacturer As In Repairs Complete All As Specified And As Directed. 29 Item No 29 Removing Of Old Earthing Materials And Taken On Credit And Provision Of New Earthing Complete With Galvanised Iron Earth Plate Electrode 600Mm X 600Mm X Minimum 6Mm Thick, With And Including Earthing Of 25Mm X 4Mm Gi Strip Protected By 40Mm Dia Gi Pipe Light Grade Upto A Length Of 7.5M. The Plate Shall Be Buried Directly In Ground Vertically To A Depth Not Less Than 2.25 Metres Below Ground Level With Top Edge Of The Earth Plate At A Depth Not Less Than 1.5 Metres Below Ground Level, Connected To Earth Lead As Described Here-In-Before By Means Of Bolts, Nuts, Washers And Checknuts Made Out Of Galvanised Iron Or Mild Steel, Earthing Lead Protected By As Described Here-In-Before And Connected To Main Switch Board Or Main Control Board Or Electric Pole All As Shown On Electrical Plate No.3 Of Mes Sch Part-I Including Necessary Earth Work And Excavation In Any Type Of Soil, Plain Cement Concrete 1:3:6, Type C1 Chamber, Reinforced Cement Concrete Cover Slab With Locking Arrangement And Handle Of 10Mm Dia Ms Round Bars 450Mm Long, 1:2:4 Type B1, 50Mm Thick With 8Mm Dia Tmt Bars At 140Mm Centre To Centre Both Ways, Gi Pipe Of Bore 20Mm Medium Grade For Watering With Funnel, Wiremesh, Salt, Charcoal, Lugs Including Testing Complete All As Specified And As Directed. 30 Item No 30 Mcb 5-40 Amps, Sp, 240 Volts, 50 Hz, Ac Supply, C Curve, With Breaking Capacity Of 10 Ka Complete All As Specified And As Directed. 31 Item No 31 Taking Out Existing Unserviceable Pipe Of Any Type And Size And Supply, Laying Upvc Column Pipe Heavy Duty ( Threaded Type ) Pipe Of Size 50Mm, Sch-80 With Necessary Fittings And Fixed To Wall And Ceiling Or Laid In Floors Or Laid In Existing Bore Holes Complete All As Specified And As Directed. 32 Item No 32 Taking Out Existing Unserviceable Ball Valve And Suppy And Fix 50Mm Size Upvc Ball Valve Suitable For Upvc Pipe Sch-80 Complete All As Specified And As Directed. 33 Item No 33 Dismantling And Taking Down The Unserviceable Starter And Supply And Fix Submerssible Pump Controller Suitable For Operation On Three Phase, 415 Volts, 50 Hz Of Capacity 7.5 Hp Complete All As Specified And As Directed. Make : Cutler Hamme / L&T 34 Item No 34 Taking Down The Unserviceable Cable And Supply And Fix Submerssible Cable, Pvc Insulated And Sheathed, Flat, 3 Core 6 Sqmm, 1100 Volts Grade With Multi Stranded Copper Conductor From Starter To Submerssible Pump Complete All As Specified And As Directed. 35 Item No 35 Stop Valves, Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed For Gi Pipe Of Size 50Mm Bore As In Repairs Complete All As Specified And As Directed. 36 Item No 36 Supply Only Sodium Hypochlorite Solution With 10% Concentration Suitable To Use In Chlorine Dosing Plant Complete All As Specified And As Directed. 37 Item No 37 Cast Iron Sluice Valve Suitable For 200Mm Bore Of Pipe With Flanged Ends Drilled With Holes, Class Pn 1.6 ( Conforming To Is 14846 ) With Brass Spindle And Checknut, Rubber Gasket 3Mm Thick, Nut, Bolts And Washers, Necessary Machining Works As In Repairs Complete All As Specified And As Directed. 38 Item No 38 Cast Iron Sluice Valve Suitable For 150Mm Bore Of Pipe With Flanged Ends Drilled With Holes, Class Pn 1.6 ( Conforming To Is 14846 ) With Brass Spindle And Checknut, Rubber Gasket 3Mm Thick, Nut, Bolts And Washers, Necessary Machining Works As In Repairs Complete All As Specified And As Directed. 39 Item No 39 Cast Iron Sluice Valve Suitable For 100Mm Bore Of Pipe With Flanged Ends Drilled With Holes, Class Pn 1.6 ( Conforming To Is 14846 ) With Brass Spindle And Checknut, Rubber Gasket 3Mm Thick, Nut, Bolts And Washers, Necessary Machining Works As In Repairs Complete All As Specified And As Directed. 40 Item No 40 Cutting / Clearing And Removing The Vegetation / Bush / Creepers Growth Any Nature / Type Around The Electric Poles / Stays So As To Keep The Area For Easy Access To Carry Out Repair / Maint Works To Poles Etc, Removing From Site And Throwing Out At A Place Where Directed At A Distance Exceeding 100M And Not Exceeding 250M Complete All As Specified And As Directed. 41 Item No 41 Cutting Of Tree Branches Of Any Type / Size Of Trees, Touching / Approaching The Electric Oh Lines / Poles Structures Etc., By Climbing On Trees, Cutting Required Number Of Branches Of Any Size / Girth Protruding Towards Oh Lines So As To Keep Tree Branches Clear / Off Not Less Than 1.5Mtr Away From Any Side Of Conductors On Poles, Removing Cut Branches From Site And Throwing Out At A Place Where Directed Not More Than 250Mtr Away From Site Complete All As Specified And As Directed. Note :-1. Suitable Ropes Shall Be Used To Hold The Branches While Cutting In Progress To Prevent Branches Falling On Oh Lines And Causing Damages. 2. In Case Of Any Damages To The Oh Lines / Poles Or Any Other Structures, The Same Shall Be Repaired / Rectified / Made Good By The Contractor With Out Any Extra Cost. 3. Shut Down Of Electric Supply Shall Be Taken Before Climbing Trees. 4. The Cut Branches Shall Be Removed From Site And Deposited At A Distance Not Exceeding 200 Mtr As Directed. 5. Each Tree Will Be Measured As One Job Irrespective Of Any Number Of Branches. Comprehensive Maintenance Including Maintenance Boq Titleand Operation Total Quantity : 29952

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-02-2022 23-02-2022

Key Value

Document Fees
Refer document
EMD
INR 112000.0 /-
Tender Value
INR 56 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail